2 WIRE INTERCOM SYSTEM
Contents
1. next page menu Aa O 00 lN o o 5 Input 4 digits code number by touching the digital keypad cancel the input save the setting 11 Screen and Volume Adjustment During monitoring or talking touch User Setup 2 Ring Volume Night Ring Volume TPC Configure Restore to default Last Page 5 Exit M Home 3 Touch Restore to default item a message will be asked Restore to Default Are you sure to Restore all to default 5 Cancel OK 4 Press the UNLOCK button on monitor and hold for 2s x icon the ADJUST MENU will be displayed select the adjustment item you want touch 4 gt icon to decrease increase the value 1 The first item is Scene mode selection Total 4 screen modes can be selected in sequence Normal User Soft and Bright Whenever you modify Brightness or colour Scene item will be set to User mode automatically 2 The Brightness and Colour item is for the image quality setting adjust the value to get the best image you like Scene Normal Bright 6 Color 6 Ratio 16 9 Talk Volume 2 5 Exit Dec Inc 3 The Ratio item is for screen display adjustment you can set to 16 9 or 4 3 4 The Talk Volume item is for talking volume adjustment 5 Note that all the modifications will be performed immediately after the operation Touch icon to exit the adjust page 12 Specification Pow
2. Ding Dong 6 Edelweiss 10 Happy Birthday DoorBell Tone gt 3 Rain 7GoingHome 11 Jingle Bells Clock Next Page 9 Exit Home 4ForAlice 8 Congratulation 12 Telephone Ring 5 Cancel 8 Home Save amp Exit Ring Volume and Night Ring Volume Setting You can set a ring volume for day time and night User Setup 2 time individually 6 00 AM 18 00 PM is the day ARP N NE 5 time and 18 00 PM 6 00 AM is the night time by TPC Configure default if you don t want to be disturbed at night you e geruit can set the night ring volume to 0 SEG eme Touch User Setup item on main menu page to enter setup page then touch Next Page item to enter User Setup 2 page select Ring Volume Setting or Ring Volume Night Ring Volume item then touch A Y icon to A increase decrease the value After finish touch Current 05 icon to save and exit touch icon to cancel the x setting and return last page touch A icon to get into Cancel f Home E Save amp Exit main menu page 7 Date and Time Setting Touch User Setup item on main menu page to enter setup page touch Clock item a digital keypad will be showed on screen input date and time by touching the digital keypad use icon to move the location After finish touch icon to save and exit touch 9 icon to cancel the setting and return last page 8 Monitor Time settig Touch Manual Monitor item on main menu page to get into camera switch mode select Monitor Time
3. Set item touch A Y icon to increase decrease the value After finish touch icon to save and exit touch O icon to cancel the setting and return last page touch fA icon to get into main menu page 9 Restore to Default 2010 12 28 5 Cancel QG Save amp Exit Monitor Time Select A Current 01min v 9 Cancel Home gl Save amp Exit Touch User Setup item on main menu page to enter setup page then touch Next Page item to enter User Setup 2 page touch Restore to default item a message will be asked to confirm the restore operation If touch icon All settings will be restored to default if you don t want to restore touch 9 icon to cancel the operation Note that the restore to default operation will not change the time setting and the datas User Setup 2 Ring Volume Night Ring Volume TPC Configure Restore to default Last Page o Exit 8 Home Restore to Default Are you sure to Restore all to default 5 Cancel OK 10 Unlock Parameter Setting Main Menu Monitor Manual Monitor Intercom User Setup Close About 1 Touch User Setup item on main menu page Note 8010 is used to set the unlock mode to 0 8011 is used to set the unlock mode to l User Setup 1 Door Station Call Tone Intercom Call Tone DoorBell Tone Clock Next Page 5 Exit M Home 2 Touch Next Page item to enter
4. to redial 2 Press TALK MON button to cancel the call 3 The DIP switches code of each monitor must set different Monitor Select o Exit M Home Intercom ntercom Call gt Exit Q Home Intercom Call 5 Exit Calling Next Page 2 Inner Call If multi Monitors are installed in the same apartment select Inner Call all the other Monitors will ring at the same time whichever Monitor answers the call conversation is started and the other monitors will stop ringing at the same time note the DIP switches setting of all monitors must be same 3 Direct Dial Guard unit A Monitor can be assigned as Guard Unit Monitor when the Guard Unit Monitor answers the call conversation with the guard person is started 6 Basic Setup Instructions Ring Tone Settings Touch User Setup item on main menu page to enter setup page Touch Door Station Call Tone Inercom Call Tone or DoorBell Tone item There are 12 pieces ring tones can be selected touch a ring tone you want then touch icon to save and exit touch icon to cancel the setting and return last page touch fA icon to get into main menu page Door Station Call Tone set the ring tone calling from outdoor station Intercom Tone set the ring tone calling from other apartments DoorBell tone set the ring tone calling from door bell User Setup 1 Door Station Call Tone Door Station Call Tone Selected 06 Intercom Call Tone 1Carmen 5 Sonatine 9 Do Re Me 2
5. ENGLISH 2 WIRE INTERCOM SYSTEM USER MANUAL Main Menu Clos About DT ENG 692TD7 V1 1 Parts and Functions LCD Touch Screen A e Microphone Main Menu e CALL button Monitor e UNLOCK button Manual Monitor e TALK MON button mercon e LED indicator User Setup Close e Speaker e Ventilation Vent e Mounting Hook e Connection Port e Mounting Hook 145 160 cm 1 Use the screws to fix the Mounting Bracket on the mounting box fitting accesories includes a Bracket Two pieces of 4X25 screws are needed for fastening the Mounting Bracket Special 2 wire cables to connect with Monitor 2 Wire the system correctly see the later connection chapter then hang the Monitor on the Mounting Bracket firmly 2 Main Menu Touch the screen anywhere on monitor in standby mode the date time page will be showed the date time page will be closed in 1 minute if no operation Touch the screen again main menu page will be showed as follows Main Menu Monitor Manual Monitor 12 28 2010 Thu 2 Intercom 06 44 AM User Setup Close About Basic Door Release Operation Press CALL button on outdoor station the Monitor rin
6. er supply for indoor monitor Power consumption Monitor screen Display Resolutions Video signal Wiring Dimension DC 24V Standby 1 5W Working status 10W 7 Inch digital color LCD 800 3 R G B x 480 pixels 1Vp p 750 CCIR standard 2 wires non polarity 155 H x225 W x 28 D mm DT ENG 692TD7 V1 The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved
7. gs at the same time the screen displays the visitor image Press TALK MON Button on monitor or touch icon on screen you can communicate hands free with the visitor for 90 seconds After finishing communication press TALK MON button again or touch icon to end the communication If nobody answers the phone the screen will be turned off automatically after 30 seconds During talking state Press UNLOCK Button or touch 81 or icon to open the corresponding door for the visitor When the monitor is in standby mode press TALK MON Button or touch Monitor item on main menu page The screen can display the view of outside If multi door stations are installed touch F icon to get into the camera switch mode or direct touch Manual Monitor item on main menu page You can touch camera 1 2 3 4 to monitor the door station or CCTV camera you want See the following diagrams Press TALK MON button again to end monitoring 5 Intercom Function When the monitor is in standby mode press CALL Button to enter Intercom Function page or direct touch Intercom item on main menu page 1 Intercom Call User in one apartment can call other apartments in the system the namelist will be created automatically by the system Touch a name you want on the screen then touch icon or press CALL Button on monitor to dial Note 1 touch icon or press CALL button again