Home

L-Vis

image

Contents

1. Even though there are a lot of things to configure creating a new project really is not that complicated If this is your first attempt to create a project it might help to concentrate on one thing at a time to avoid unnecessary confusion caused by switching back and forth between objects and their different property pages A simple workflow is suggested below e First build the desired object hierarchy using the tree view at the left Use the context menus to add cut copy and paste objects and use drag and drop inside the tree view to move existing objects around It is also possible to have a second instance of the configuration software running and copy paste objects between the projects In the property view keep the General property page open and enter names and descriptions for your objects as you create them Do not get lost in detailed object configuration at this time e You should now have an object tree containing at least the hierarchy of menus menu items pages and the basic controls which will be used to display and enter data All objects should be clearly named Now is a good time to go through the menus and configure their basic appearance Select one menu at a time from the LOYTEC electronics GmbH L Vis User Manual 48 LOYTEC tree view and keep the Common Properties page open in the property view For each selected menu enter a menu title in the Text field and select the desired font With the Common Properti
2. e Type The desired type of the network variable The available types in this dropdown depend on the resource file selected before e Direction Input or output as seen from the network side e Functional Block The functional block in which the NV should be located L Vis provides an array of eight functional blocks to organize your NVs and keep them separate from other NVs on the device which are managed by the device firmware e NV Flags Flags for the newly created NV You may leave these untouched Most of the flags will be handled by the network management tool later on The most important one which cannot be set by other tools is the polled flag This is automatically set for newly created NVs as required 9 3 3 Local Server Object BACnet NOTE Version 3 1 On BACnet models local server objects may be created to communicate with other devices on the network The basic object types supported are analog binary and multi state each available as input output or value object Since a value object may be read and written much like a register two data objects will be created for each value server object BACnet defines the direction of data flow from the point of view of the application running on the L Vis device An analog input object therefore accepts input from the user and transmits this data out to other devices on the network An analog output object receives data from the network and outputs it to the application sho
3. Contra 16 A el Sue IRA H Figure 23 Hiding pages 14 3 Example 3 Freeze warning Alarms and Registers Version 3 1 This example shows how to create a translation table which converts a numeric value to a text value and to generate an alarm output on special occasions It also shows how to use registers to exchange data between internal objects The example takes an nvoTemp input data point and checks 1f it is below 0 C freeze warning or not It controls an output text and an alarm output register of type SNVT_alarm 2 Generate a new menu item Example 3 and a page for this menu item and name the menu item and the page Generate a header for the page Freeze Warning Add a new text control to the page Set a label for the text control e g Temperature State s in the text field of the Common Properties tab Add the nviTemp data point to the text control Select the Mapping tab on the data point Select New enter 0 for the value and FREEZE for the text Add two more mapping values 0 1 ATTENTION and 3 NORMAL to the mapping table This will cause that for input LOYTEC electronics GmbH L Vis User Manual 146 LOY TEC Version 3 1 values up to 0 1 C the FREEZE text will be shown Values between 0 1 C and 2 99 C will show ATTENTION where as values starting with 3 C will show NORMAL in the text control Figure 24 shows a screenshot of the mapping table General Common Properties Mapping Data Point 0 00 FREE
4. L Vis LOYTEC Visualization User Manual LOYTEC electronics GmbH L Vis DLOYTEC LOYTEC Visualization Contact LOYTEC Blumengasse 35 A 1170 Vienna AUSTRIA EUROPE support loytec com http www loytec com Version 3 1 Document No 88068510 LOYTEC MAKES AND YOU RECEIVE NO WARRANTIES OR CONDITIONS EXPRESS IMPLIED STATUTORY OR IN ANY COMMUNICATION WITH YOU AND LOYTEC SPECIFICALLY DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THIS PRODUCT IS NOT DESIGNED OR INTENDED FOR USE IN EQUIPMENT INTENDED FOR SURGICAL IMPLANT INTO THE BODY OR OTHER APPLICATIONS INTENDED TO SUPPORT OR SUSTAIN LIFE FOR USE IN FLIGHT CONTROL OR ENGINE CONTROL EQUIPMENT WITHIN AN AIRCRAFT OR FOR ANY OTHER APPLICATION IN WHICH IN THE FAILURE OF SUCH PRODUCT COULD CREATE A SITUATION IN WHICH PERSONAL INJURY OR DEATH MAY OCCUR No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without the prior written permission of LOYTEC L Chip LC7093 L IP and L Gate are trademarks of LOYTEC electronics GmbH LonTalk LonWorks Neuron LONMARK LonMaker i LON and LNS are trademarks of Echelon Corporation registered in the United States and other countries L Vis User Manual Version 3 1 3 LOYTEC Table of Contents I Introduction eier ea 9 LE
5. and are considered longest first nested constructs are considered from the outermost in and concatenated constructs are considered leftmost first The match that will be chosen is the one that uses the earliest possibility in the first choice that has to be made If there is more than one choice the next will be made in the same manner earliest possibility subject to the decision on the first choice and so forth For example ab a b c could match abc in one of two ways The first choice is between ab and a since ab is earlier and does lead to a successful overall match it is chosen Since the b is already spoken for the b must match its last possibility the empty string since it must respect the earlier choice In the particular case where no Operators are present and there is only one or the net effect is that the longest possible match will be chosen So ab presented with xabbbby will match abbbb Note that if ab is tried against xabyabbbz it will match ab just after x due to the begins earliest rule In effect the decision on where to start the match is the first choice to be made hence subsequent choices must respect it even if this leads them to less preferred alternatives LOYTEC electronics GmbH L Vis User Manual 165 LOY TEC 17 Revision History 2004 11 03 Initial revision V1 1 2004 06 04 New screenshots added configuration chapter fixes 2006 01 24 Changes for L VIS 3E100 2006 04 04 Added d
6. right click on the folder named BACnet Network Scan and select the item Scan BACnet Network Discover the devices on the network select the L Vis device and scan it for objects Close the scan dialog and use the two server objects found by the scanner to create corresponding client mappings Please see section 9 3 4 for a detailed description At this point there should be two data points in the folder called Server Objects and two data points in the folder called Client Mappings The client mapping points are input points which basically refer to the current value of the server objects located on our own device but the same procedure can be used to refer to any other server objects on other devices 2 4 4 Create Menu Structure and Pages Version 3 1 The next step is to design a simple test page for this tutorial and use the data points to set and display values The empty project shows the root menu with no entries menu items You may change the name of the root menu as well as its colors and other properties such as the width of the menu or its scroll bar using the property pages to the right of the tree LOYTEC electronics GmbH L Vis User Manual 22 LOYTEC NOTE view make sure the root menu object is selected which should be the case right after you started the software The menu object is described in detail in section 8 2 First add a menu item to the root menu To do this right click on the root menu object in the tr
7. 14 1 Example 1 Working with Structured Network Variables ccccccsees 141 IE TEx CONTO ee el 141 AA Bilmap Controls 142 ALA Numene Control aaa 143 14 2 Example 2 Using Data Point conversion and Hiding of Pages 144 14 3 Example 3 Freeze warning Alarms and Registers ooooosssss o 145 14 4 Example 4 Using text mapping and Date Control scsssssssssseees 147 IS Solutions u SERIE 150 15 1 Implementing Men s 150 SET Rab De HS ensure 150 15 12 1600 Men sosa 152 SAL O Raskbar MEU Sinai 153 ESA ee ee 153 13 2 Ee Control Het 154 153 Animated BAM a 155 15 4 Sunblind DM usina nie 155 15 3 Split Demo ida deeweasseavaestsecnees 156 15 6 Counter Demo isi ias 157 16 Appendix A Format strings sssssssceccoosssesseccoocssseescecossosssessceosssssssssee 159 16 1 Number format strmss uu iekae a NE EAEE 159 ESA E ee ee 159 TO EZ ER II WIN euere ee 160 AAC re 160 MALE 160 IO LS Conversion Pecera 160 16 2 DatetormatStrntsanciiand is 161 16 3 Regular EXpressions sosise oisein ea aaaeeeaa A a ENa 163 LOSS yA air 163 163 2 AD ie 164 17 Revision Storni 165 LOYTEC electronics GmbH L Vis User Manual 9 LOY TEC 1 Introduction 1 1 What is L Vis Version 3 1 L Vi S DLOYTEC LOYTEC Visualization networks under control L Vis 1s a highly flexible and easy to configure device to display and control data in BACnet and CEA
8. Assign good names to your trend control objects to make it easy to identify the data files and relate them to the trends which are visible on the device Consider to add the name of each trend to the page where the trend is shown so that the user is able to clearly identify each control and its data file If the trend control object name contains non ASCII characters the resulting file name will be encoded in ISO 10646 Unicode and will be transferred to the client in UTF 8 encoding according to the FTP protocol extension RFC2640 Clients who support this extension can then display these file names correctly Most web browser based FTP clients either detect the UTF 8 encoding automatically or provide an option where the user may set the desired encoding To maximize compatibility to existing FTP clients it is desirable to use only ASCII characters for the name of trend control objects An easy way to manually access the files on the device is to use the windows explorer or a web browser and type the following into the address URL field ftp lt user gt lt address gt Replace lt user gt with the user name for data access as defined in the project settings and lt address gt with the IP address or DNS name of the device for example ftp data 192 168 1 20 You will then be asked for the password and the file system contents will be shown You can now navigate to the required files and download them to the local hard disk of your PC
9. L E PLLightv alan Werbe For Help press Fl Figure 4 Main window of the L Vis configuration software 7 2 Context Menus Context menus are an important part of the workflow since most operations related to the objects of the L Vis project are accessible from the context menu of the object in question The context menu is usually opened using a right mouse button click on the desired object in the tree view but for objects visible in the LCD preview the same context menu may also be opened by a right mouse button click on the preview of the desired object Commands accessible via the context menus are detailed in the following sections Version 3 1 LOYTEC electronics GmbH L Vis User Manual 44 LOY TEC 7 2 1 Add Objects Most context menus contain a number of Add commands to add new objects to the selected object Only those objects which may be added to the selected object are listed n the context menu 7 2 2 Enable Disable Access Control These commands are available in the context menu of menu objects and menu item objects The command Enable Access Control will go through all pages below the selected menu or menu item and turn on the Locked Page flag for all pages which have a non public access level set The command Disable Access Control executes the inverse operation turning off the Locked Page flag on all pages below the selected object This function is useful for testing purposes 7 2 3 Cut Copy Paste Ever
10. The main window will show this selection when the data point manager window 1s closed From this first occurrence you may use the Find Next function or F3 of the main window to find similar references throughout the project 9 3 Object Creation New objects can either be created manually or from template objects which were automatically created based on information provided by a file or a network scan The various objects and the way to create them are explained in the following sections 9 3 1 User Register A new user register 1s very easy to create Select the folder named Register and click the New button A new dialog appears asking for two names a Datapoint Name and a Register Name The first one is used as a base name for the data objects which will be created The suffix Read or Write will be appended to this name to identify the read and the write point The second is the name of the register itself You may leave either one or even both names empty in which case a suitable default will be chosen 9 3 2 Local Network Variable CEA709 NOTE Version 3 1 For CEA709 models local network objects refer to local network variables on the L Vis device If there are dynamic NVs present on the device suitable data objects will be created automatically All manually created objects will therefore create additional static network variables on the device Adding removing or otherwise changing the static network variables of a CEA
11. the field width the field is expanded to contain the conversion result 16 1 3 Precision An optional precision in the form of a period followed by an optional decimal digit string If the precision is given as just or the precision is negative the precision is taken to be zero This gives the minimum number of digits to appear for d i o u x and X conversions the number of digits to appear after the radix character for a A e E f and F conversions the maximum number of significant digits for g and G conversions or the maximum number of characters to be printed from a string for s and S conversions 16 1 4 Length Modifier The conversion specifier may normally be preceded by a length modifier defining the physical size of the arguments data type In the L Vis implementation this modifier is not necessary and may be omitted in all cases 16 1 5 Conversion Specifier Version 3 1 This is the character that specifies the type of conversion to be applied The available conversion specifiers and their meanings are d I The int argument is converted to signed decimal notation The precision if any gives the minimum number of digits that must appear if the converted value requires fewer digits it is padded on the left with zeros The default precision is 1 When 0 is printed with an explicit precision 0 the output is empty 0 u x X The unsigned int argument is converted to unsigned octal 0 unsigned decimal
12. u or unsigned hexadecimal x and X notation The letters abcdef are used for x conversions the letters ABCDEF are used for X conversions The precision if any gives the minimum number of digits that must appear if the converted value requires fewer digits it is padded on the left with zeros The default precision is 1 When 0 is printed with an explicit precision 0 the output is empty e E The double argument is rounded and converted in the style d dddetdd where there s one digit before the decimal point character and the number of digits after it is equal to the precision if the precision is missing it is taken as 6 if the precision is zero no decimal point character appears An E conversion uses the letter E rather than e to introduce the exponent The exponent always contains at least two digits if the value is zero the exponent is 00 f F The double argument is rounded and converted to decimal notation in the style ddd ddd where the number of digits after the decimal point character is equal to the precision specification If the precision is missing it 1s taken as 6 if the precision is explicitly zero no decimal point character appears If a decimal point appears at least one digit appears before it LOYTEC electronics GmbH L Vis User Manual g G 161 LOYTEC The double argument is converted in style f or e or F or E for G conversions The precision specifies the number of significant digits If the
13. 5 in Le 04 in Angle 0 deg Page 111 Figure 11 New dynamic network variable 11 4 2 NL220 To create dynamic network variables in NL220 add the L Vis device to your project In the context menu of the L Vis device go to Virtual interfaces and select New interfaces Enter a name for the new virtual interface e g L Vis 1 and click on OK Figure 12 shows the L Vis device with the new virtual interface Version 3 1 LOYTEC electronics GmbH L Vis User Manual 123 LOYTEC l2lx aes Sem Br IE 2 ee 549 X Ol we GB Lis vin E Static mindace na ae daca lao DIESE me am ae Sus in ent we ES T foe fo ol fl i J pct ff Corse _ Se Jf Roody NE din Advanced 62 09 2001 06 30 Figure 12 Create new virtual interface To create a new dynamic network variable go to the node which holds the complementary network variable of the new dynamic network variable to be created The new dynamic network variable will use some of the properties of the complementary network variable e g SNVT type Drag the complementary network variable and drop it on the Interface object of the virtual interface In the dialog Figure 13 enter a name for the new dynamic network variable and set the direction and the poll attribute as required When done click on OK NOTE Make sure to set the poll attribute of the NV to Set if you are creating an input NV in order to allow the device to support the receive timeout and
14. Alarm Generator Properties Once all inputs and the output are connected the alarm generator may be configured on the Alarm Generator property page For each of the connected inputs an independent set of parameters is required The available input points are listed in the top left area of the property page NOTE If logic or arithmetic operations are required to determine an alarm condition for example signal an alarm when TI gt T2 a mathematic object is required to conduct the required operations The result which is conveniently stored into an internal register is then monitored using the alarm generator The suggested workflow to configure the alarm generator is as follows Version 3 1 First select the input point for which the monitoring rules should be configured Define the Alarm Condition using the radio buttons at the bottom left of the page The available choices allow basic monitoring functionality and always define the condition under which the alarm should be SET If the value no longer satisfies the condition the alarm will be cleared To filter out spikes it is usually good to set an amount of time which the alarm condition needs to be satisfied before the alarm is actually set The default of one second 1s often a reasonable value Define the Data Point Value Range Depending on your choice for the condition you may need to enter values either for both minimum value and maximum value or only for one of the tw
15. At this point the Execute Action part of the property page should be filled in completely The contents of this section should result in a meaningful command when read as a sentence for example Sound buzzer on touch Repeat action 3 times waiting 200ms after each time If you read your settings make sure they make sense and match your goals For example you should not end up with a sentence like this Next page on release While touched waiting 100ms after each time The resulting action even though it is possible to configure it this way will not do what you want There are two major problem areas e The action is requested to trigger on release of the control yet the condition under which the action is to be executed requests the control to be touched This is a contradiction and will not be satisfied e Even if the trigger were to be corrected using on touch it is very unlikely that you would want this action to show a new page every 100ms while the control is touched Aside from the delay which would be too small there is another major problem here After the first time the action is executed a new page will be on the display and the original control will be gone so you cannot hold on to it The delay value waiting xxx ms after each time always applies The action trigger will always be locked for the given duration after each time the action fired preventing the same action to fire again until the wait time expi
16. File menu e Load the project from the file and download it to the device A warning will appear stating that the static interface will change and that an already integrated device cannot be upgraded This is OK since we are changing the interface so that it will match the already integrated device e Once the device restarted it is ready to use Connect it at its final location replacing the old device and use the standard procedure of your network management tool to replace the device If an XIF file is required for this Operation you may use the one which was originally used to integrate the device or create a new one from within the configuration software In case it is not possible to program the new device using a standalone connection the procedure becomes more complicated because the device needs to be commissioned in the network to be programmed but the device currently in the database does not match the empty device and cannot be used for this task The following procedure 1s recommended in this case e Create a new database or network project in your network management tool adding the PCs network interface and a new L Vis device and connect them using a suitable channel e Connect the new device physically to the network interface of your PC or otherwise make sure that the PC can communicate with the device in the new network project e Commission the new device e Run the configuration software on the empty device a
17. Netzwerkvariablen 12 Funktioesecinheil on 13 Virtuelle Funktionseinheiten 1 DB vs a Netzwerkvariablen 0 Parameter 0 amp Verbindungen 0 er Switch Router 0 30 Untersysteme 0 2 Kan le 1 3 Gerilevorlagen 5 A Ol 01 08 2004 12 09 Figure 17 Create new network variable In the Netzwerk Variable dialog Figure 18 select the device template Ger tevorlage and the network variable to which the new dynamic network variable will be connected Version 3 1 LOYTEC electronics GmbH L Vis User Manual 126 LOYTEC Allgemein Netzwerk Variable Marne i Name Inviswitch Anzahl 1 Urpsrungs Netzwerk Wariable gt Ger tevorlage SCHALTER X Variablen dieser Ger teworlage bal nciLocation it nyostabus A e nvoswich 22 Richtung der neuer Netzwerk Variable Eingang Figure 18 New network variable dialog The dynamic network variable will get attributes like the SNVT type from this network variable Select the direction of the new dynamic network variable and enter a name for the network variable Finally click on OK to confirm the creation of the new network variable Figure 19 ig ALEX 3 0 LYISDemo Subsystem 1 LVIS L VIS L nviSwitch Ostel Dearbeken Ansicht Extras Fenster 7 Paria gt E God Y a OSX T Pfad IB Lwisbemo Subsystem L LVISAL 1S IS Projekte 1 z ES T 2 dd LYISDemo Verbringen 0 Struktur Demente 0 39 Untersysteme
18. Page 2 To each of the inactive page bitmap controls an action object is assigned The action to execute is to change to the respective page This setup has to be copied for each page but he location of the active page bitmap changes according to the page on which the controls are placed The same mechanism can be used to build tabs on the bottom which is also shown in the menu project Tab Menu Bottom Figure 32 Ea DE Mabi Pree e io DO Lae amg Din Diim LA 49 Qu Usage Fega Boot Menu Tab Marsa Tat Femna LE Tab Henu Eem T Pa L A Pr ran Gere Comme Pope Eta Pora Coke Mier Page TD tn tere he It Ddrama E id Merny ee j ee tn E wan T E 0 el Hei el a P a pi 2 Ti Hu Bes 1 i fe Por Het passa Fa Kees Bew Pepe bi We jii E fee Miki Figure 32 Bottom tab menu solution Another tab solution in the project shows how to implement flat tabs but using only line bitmaps In that solution the action objects are assigned to the text controls The leftmost button in that case opens the main menu Figure 33 Version 3 1 LOYTEC electronics GmbH L Vis User Manual 152 LOYTEC nn Menu Room 1 Room 2 Pow Fics premi F1 Fe Gem Fuge ED Contre Dago iD So Si Figure 33 Flat tabs and menu button 15 1 2 Icon Menus Another common implementation to navigate in menu trees is to use Icon menus as shown in the icon menu example see
19. Proper ES ie 86 8 122 Application Hinsehen 87 8 12 gt AP CTO Laia 87 9 Data Point Management 90 DA Concept ace en edad es state eee 90 D2 User Interface Ra A E SS 91 9 2 1 Folder List 2 2 ER I 91 9 2 2 Dan Object Lit do 92 9232 PODEN VIEW essen een 93 JA reed eseinssaseiehin 93 93 Object Creation ri AS ii 93 9 3 1 A een es 93 9 3 2 Local Network V anable CRAI09 ia eas 93 9 3 3 Local Server Object BACnet ee tt 94 9 3 4 Remote Network OD ck ae ne 95 94 Local Scheduler and Calendar rscnensnsiennnnnnsnnne 97 Sal JOU CTE AON state 97 9 4 2 Calendar Point Configuration nahen en 97 9 4 3 Scheduler Point Conlara 98 LOYTEC electronics GmbH L Vis User Manual Version 3 1 6 LOYTEC 9 4 4 Schedule Configuration Data cooccccccnnncnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnos 98 AN Resouressa seater cree ee ee 99 940 Resource AOC At nennen 100 94 7 Usina tie AMA 101 95 socal Alarm PR a A AAEE 101 A a A 101 95 2 ii O 102 93 3 System RESOULCES ee ias 102 93 4 SiG AAC ee 102 9 6 Remote Scheduler and CalendaP ccccssssssssssssssssssssssssssssssssssssssssssssees 102 9 7 Alarm Chen ask osios a naeh 103 9 8 E Mail Templates aiaa 104 9 8 1 Common E Mail Properti8s ooccccccccnonononcnnnnnnnnnnnnnnnnnnnnnonononnninininnnos 105 982 EMail Insert A En 105 9 8 3 AMA CAMS id 106 10 Standard Procedures CEA709 ssccccsssssccsssssscccssssc
20. RNI page of the setup menu The CNIP port setting should normally be set to 1628 and the NAT mode should be set to automatic Configuration Server Add the L Vis device to an IP 852 channel To do this add the IP address of the L Vis device to the channel list in a configuration server e g on an L IP and restart the L Vis device L Vis will then wait for the configuration server to contact it and provide the necessary channel information If the device was a member of a different channel before it will not wait an instead boot up with the already known channel information The configuration server will then reconfigure the device to become part of the new channel Check configuration server To check if the L Vis device was correctly added to the channel enter the CEA852 RNI page in the setup menu The configuration server field should now display the IP address of the configuration server During system start when the device is used on an CEA852 channel for the first time it waits for a configuration server to contact it within 30s If this is not successful for 30 seconds the device will switch back to CEA709 mode and boot up so that you may make modifications to your settings and try again The same applies if DHCP was enabled and the unit is not able to get an IP address for 30 seconds LOYTEC electronics GmbH L Vis User Manual 34 LOY TEC 6 Operating L Vis 6 1 Touch Screen 6 1 1 Operation Version 3 1 This section descri
21. TCP IP for the connection e After the device restarted use the Export XIF function from the Tools menu to generate a new XIF file matching the new configuration of the device e Execute the standard procedure of your network management tool to replace the old device with a new device and use the new XIF file to define the new interface The above procedure assumes that there are no dynamic NVs present on the device Manually changing the static interface of a device is not supported by any of the common network management tools when there are dynamic NVs present at the same time Therefore updates to the static interface in mixed projects can only be done in plug in mode 10 4 Configuration Recovery This section describes procedures to recover from situations where the current configuration of the device does not match the current definition of the device in the network This may happen as a result of a failed upgrade procedure or because the definition of the device in the network changed because the network had to be restored from an older backup Basically there are two ways to resolve any such conflict e Change the configuration of the device to match the current definition in the network e Change the definition of the device in the network to match the current configuration The decision depends on the desired end result that is if the current network definition or the current device configuration is closer to the de
22. The configuration software contacts the device finds out what model and firmware version it is selects the correct settings and disables the corresponding menus so that you may not change them The main window will show an empty L Vis project The list of dynamic network variables available on the device 1s automatically read in and a list of corresponding data points to access the NVs is generated These data points will be used in a later step If no dynamic NVs were created in the previous step the required NVs and data points will be created in the configuration software later on In case the device was not commissioned yet or there are other communication problems the plug in will display a warning message saying that it could not communicate with the device and therefore was not able to determine model or firmware version In this case you have to commission the device or find out why it cannot be commissioned Typical errors are devices in the wrong mode jumper set for CEA852 but connected to FT 10 or vice versa or communication problems on the channel itself Especially on a channel as complex as CEA852 there are a number of possible reasons why you may not be able to communicate with the device The main window is divided in tree major sections Tree View On the left side of the main window is a tree view showing all objects you created so far and how they relate to each other for example a menu object may have menu item object
23. To insert a new entry either touch the insert line in the left column append at the end of the list or touch the entry at the position where the new entry should be inserted the selected entry and all following entries will be moved down LOYTEC electronics GmbH L Vis User Manual 40 LOY TEC NOTE Insert may not be possible if the calendar object reports that the limit of entries is reached or if the calendar does not allow insertion of new entries at all for example embedded BACnet calendar objects may be fixed to exactly one entry The new entry will be a single date entry If the type should be changed touch the type and select the desired type from the dropdown menu To remove the entry select the remove command from the same menu To edit the data of the entry touch the individual components of the dates to open up a dropdown list with various choices One of the choices will always be value to open a keypad and enter a value Other choices may be available depending on the selected element For most entries the choice any will be available to set this component to the wildcard For months the choices odd and even may be available to specify all odd or all even months For days the option last may be available to specify the last day of the month To save the changes done to the exception day patterns close the window using the close button in the top right corner of the window This will update the calendar object with t
24. Whati VAS een 9 1 2 COM cessdinssessvectosdstexscscssccasusiasvacsstactecsouevsscsadevbacddacvassstuactocseuanacsssnecacctiaavacdsieesaeds 11 De GOCE SCATUC owas cesesscsccvessssscactevscceowssestawssesaaasseusscnaassacasessseasuvowsosnasacsetoenss 12 2 1 Installing the L Vis Configuration Application ccssssssssssccccccsseees 12 2 2 CONNCCUNE LO CHE Device ua Bil 12 22 1 SRA TOO DEVICES ee ek 12 22 22V BACH Don s Cc een meee Renn ROPE seele ee 14 2 3 Quick Start Tutorial CHAT 09 une 15 2 3 1 Add the device to the network occcccccnnnnnnccccncnnnncnnnnnnnnnnonininicininaninnnns 15 2 3 2 Create Dynamic NVs LNS OH Yen ee 15 2 3 3 Start the L Vis Configuration Software sssssssssssssssssnnnnnnnnnnnnnnnnn 16 2 3 4 Create Static NVs if no dynamic NVs available 17 2 3 5 Create Menu Structure and Ps 17 236 Add Controls tothe PACS a nee E 17 2327 Connect the Datas Omnis a u 18 23 8 Write the Project to the LAS di 19 239 A a e a EN 20 24 Quick Start Tutorial BACDO diu lid 20 2 4 1 Add the device to the network ooccccccccnccccccnnnononnnnnnnnnnnnnnninininininaninans 20 2 4 2 Start the L Vis Configuration Software cccccccccccnnnnnnnnnnnnnnnananananananannnnnn 20 DAD Created Data PONS adas 21 2 4 4 Create Menu Structure and Pages ooccccnnnnccccncnnnononenenineninnnnnnnnnnnnninininnn 21 24o AGU Contool tothe MA A A 22 2 4 6 C
25. a mathematic object The mathematic object is feed by the system time and performs a modulo operation on this input An additional enable register parameter allows to enable or disable this modulo operation 15 4 Sunblind Demo The project Solution examples manual lcp contains a Sunblind Demo page Version 3 1 LOYTEC electronics GmbH L Vis User Manual 156 LOYTEC i Solution_examples_manual 1 L Yis Configuration File Edt Model Firmware Yiew Help D k ite gsn Status Subsystem L L VIS ONNET Action loot Menu Example Pages sunblind Example Back Icon go back Root Menu l Meru Naviga ion General Common Properties Mapping Data Point Color Action Main Menu Fxample Pages Execute ction PY switch Example SN y on setection vl S le pd rn Execute once limes wabng SUU ma alter cach time iT Pos Label 4 Pos 3 Label 5 4 Position 1 L LOYTEC py Position 2 Sinau buzzes Al Hz hn mes i HEF Position 9 Up Bitmap Page Root Menu Menu Navigation Main Menu 4 Stop Bitmap gt 9 Down Bitmap 9 Dack Icon BD go back Animation Example Spit Example Counter Demo Increment by 10 Decrement by 10 Merge Bits Position 1 Position 2 Position 9 S Menus 1 Items 3 Pages 6 Controls 44 Datapoints 41 Size 134 Math Cibjects Counter 4 Figure 39 Sunblind demo configuration Like in the switch ex
26. a sample project The project can be found in the Projects directory of the L Vis configuration software install directory Users Manual Color Icp 14 1 Example 1 Working with Structured Network Variables This example describes how to work with structured network variables like SNVT_switch It explains how structured input and output network variables can be used with different controls This example assumes that a dynamic input variable of type SNVT_ switch nviSwitch and a dynamic output network variable of type SNVT_switch nvoSwitch is already present on the node We will use the output variable to update the value on the network and will use the input variable as a feedback value from the network The example explains how to use this setup with different controls 14 1 1 Text control Version 3 1 With this example we will be able to show the state of a SNVT_ switch e g a lamp and control the state from the L Vis device using a text control Text controls are typically used to display a complex text or to allow input where the user can select between several different input strings e g HIGH MID LOW To use the SNVT_switch variables with a text control perform the following steps The control only changes the state value of the output network variable and fixes the value element of the network variable to 100 e Add a text control to the page e In the common properties tab add a label to the format string in the Text f
27. a suitable format string for text mode set the Style of the control text or graphic and modify the look of the Graphic Style The date format string for text mode can also be entered directly on the Common Properties page The exact format to use is described in section 16 2 of this manual On the Color page the following colors may be set Color Name Element to which the color applies Text color of the clock in text mode Hour tick marks in graphic style Hour and minute hands Table 15 Color assignment for date controls Output data points may be connected to a date control in which case the date control becomes a date input control The user may then input a date and time using the keypad The number of seconds which passed since the first of January 1970 and the given date time will be written to the connected output data points This value is suitable to write to the system time set register to update the current system time on the device However note that due to limits of the underlying operating system the system time of the device may not be set to a date before 1 1 1988 8 5 8 Data Log Control Version 3 1 Data log controls are used to record data based on events as opposed to trend log controls which record data continuously over time The result of a data log is a list of data records which were recorded at specific points in time Each data record is composed out of one or more visible elements to display the rec
28. available To find the current firmware version of your device use the Device Info menu item in the View menu which will be enabled when the software is connected to a device or go to the About Page on your device While it is always possible to upgrade to a newer firmware and keep the device fully functional without changing its configuration data it is often not possible to downgrade to an older firmware version since the older firmware may not be able to read the data stored by a newer firmware If a downgrade is necessary it is strongly recommended to first clear the device reset to factory defaults before conducting the downgrade To upgrade the device with a new firmware select the Upgrade Device menu item from the Firmware menu which will be available when connected to a device While older versions of the firmware also allowed to upload the current firmware from the device this is not possible anymore in current firmware versions due to technical limitations It is therefore suggested to keep a copy of the downloaded firmware somewhere on a PC in case the device needs to be set back to this version at a later time 13 10 Avoiding Update Loops Version 3 1 Especially when a lot of data point connectors and mathematical objects are used in a project the danger of accidentally creating update loops increases and the user needs to be aware of this problem An update loop means that a single update of one data point cause
29. but a leading zero is replaced by a space Modifier use alternative format see below The ISO 8601 year with century as a decimal number The 4 digit year corresponding to the ISO week number see V This has the same format and value as y except that if the ISO week number belongs to the previous or next year that year 1s used instead Like G but without century 1 e with a 2 digit year 00 99 Equivalent to b The hour as a decimal number using a 24 hour clock range 00 to 23 The hour as a decimal number using a 12 hour clock range 01 to 12 The day of the year as a decimal number range 001 to 366 LOYTEC electronics GmbH L Vis User Manual Version 3 1 Yk ol om M Yon 0 Yop P r oR Ys S ot T ou U Y V W YW X YX Voy Y Z Z 162 LOYTEC The hour 24 hour clock as a decimal number range 0 to 23 single digits are preceded by a blank See also H The hour 12 hour clock as a decimal number range 1 to 12 single digits are preceded by a blank See also I The month as a decimal number range 01 to 12 The minute as a decimal number range 00 to 59 A newline character Modifier use alternative format see below Either AM or PM according to the given time value or the corresponding strings for the current locale Noon is treated as pm and midnight as am Like p but in lowercase am
30. by the user The menu items or the correct model and firmware version as reported by the device are automatically checked The real time preview of the LCD is automatically adjusted to reflect the behavior of the reported firmware version and the project is saved in a format readable by the firmware of the connected L Vis device The configuration software is always backwards compatible to older firmware versions so that 1t is possible to use newer configuration software with older devices Also the devices are backwards compatible to older project versions so it is possible to use older configuration software with newer devices as well LOYTEC electronics GmbH L Vis User Manual 137 LOY TEC NOTE NOTE When using older configuration software to connect to newer devices the software will not recognize the firmware version reported by the device since this firmware was not available at the time the configuration software was built In this case the software will output a warning and save the project in the most recent version it knows This will be readable by the device due to the devices backwards compatibility to older project files but you may not be able to use all features and the LCD preview may not accurately reflect the behavior of the device It is therefore suggested to first upgrade the configuration software and then upgrade the devices The firmware of the L Vis device can be upgraded as newer firmware versions become
31. changes to the static network interface for example you are just working on the graphics adding or modifying controls and so on it 1s more efficient to use one of the other connection methods The configuration software will detect any change in the static network interface beforehand and display a warning before you commit to the project download ADVANTAGES e No need to set up TCP IP connectivity e Easy device selection from within your management software e Automatically updates the LNS database and re commissions the device if necessary e Functions to export and import current bindings to and from the device into CSV files e Any dynamic network variables created on the device will show up as usable data points in your project including the name of the functional block in which they are located LIMITS e Download of large projects or firmware upgrade is slow due to the limits of the communication channel This s especially true for devices in FT 10 mode 2 2 1 2 TCP IP Ethernet Connections Version 3 1 This method connects to the device through a standard TCP IP channel Data is transferred using the FTP protocol therefore the PC running the configuration software must be able to establish an FTP connection to the device TCP IP connections are possible even when the device operates in FT 10 mode since the IP port is always active The IP address network mask and gateway must be configured via the setup menu
32. configuration tasks you may be doing to other devices at the same time If the project used static and dynamic NVs and the upgrade required a change of the static interface your dynamic NVs may be lost and the replace procedure may report data points which cannot be assigned Remove them from the project and continue e Once the device is replaced and commissioned run the configuration software in plug in mode e If the device lost its dynamic NVs use the function Recover DynNVs from the Tools menu now to recover the set of dynamic NVs which were removed during the last upgrade e Most likely the bindings will be lost as well Use the function Recover Bindings from the Tools menu to recreate the bindings as they were recorded before the upgrade procedure started e Ifthe replace procedure reported missing dynamic NVs before the project has to be loaded again Clear the current project data from the editor and re open it from the project file e Program the device to restore the system to the last working state 10 4 3 2 Failure after Database Update Version 3 1 If the procedure failed after the database update that is the device successfully loaded the new project and the database was updated to match the new static interface the only things which could still be missing are dynamic NVs and bindings which would need to be restored after the database update There are two possible options from here e Try to find the
33. create a bar control select Add Bar from the context menu of the preview frame Name the bar graph e g Temp Bar in the General tab e On the Bar Graph tab enter the value range for the bar graph e g 20 to 40 and set the flag for Thermometer Style e Select Add Data Point from the context menu of the bar graph From the data point template list select the nviTemp input data point e Make sure that the Value Translation Setting on the Data Point tab is set to OFF LOYTEC electronics GmbH L Vis User Manual 145 LOYTEC e Select the page in the tree view In the context menu of the page choose Copy Go to the menu item e g Example 2 open the context menu and choose Paste A copy of the page is inserted n the menu e Change the name and text of the page to Temp Example F e Select the input data point which is connected to the bar graph in the newly created page Set the Value Translation Setting to C gt F e Depending on whether the Temperature should be shown in Fahrenheit or Celsius set the Invisible Page flag on the Menu Page tab of the corresponding page Load the project into the L Vis device Only the page which does not have the Invisible Page flag set shows up in the L Vis device see Figure 23 d Ur Mad 101 1 L Wis Configuration es Heb O pra A a EA Pre Llaga Page Mar Mero Gogh tober Enri ee 3 Temp campa F E Gobel tjai a T LOYTEC For Heb pra Fo Meru E HS Page
34. data window will be updated accordingly If there is more than one page the number of history pages was set to 1 or more the user can flip through the pages by moving the cursor to the rightmost or leftmost end or touching the rightmost or leftmost end of the time axis Small arrows will appear on both ends of the time axis to indicate a good place to touch if you want to flip pages The control will return to normal operation when another control is selected or the user touches any other location outside the selected trend control LOYTEC electronics GmbH L Vis User Manual 67 LOY TEC 8 5 7 Date Control The date control is a specialized control to display date time and calendar weeks In most cases the internal system time data point will be connected to the date control However it is possible to assign any scalar data type to the date control In that case the received value will be interpreted as the number of seconds since the first of January 1970 There are two different display modes for a date control a text based mode and a graphical analog clock simulation Even though one date control can only use one of the two modes at a time two or more date controls may be used together to display the time as an analog clock and the date as text on the same page A font for the text mode can be selected on the Common Properties page All other settings can be done on the Date Time Control property page There is a wizard to generate
35. devices on the control network to send out new data the user entered through the device and to receive new data which is then displayed operation One of the two interfaces is the IP interface Ethernet 10 100Base T which is always available for configuration and may also be used for operation although different protocols will be used for the two tasks as shown in the table below The second interface is a specialized control network interface like FT 10 for the CEA709 devices and MSTP for the BACnet devices Only the CEA709 models are currently able to use their control network interface for configuration as well The BACnet models need the IP interface for configuration Configuration FTP oooga p Configuration FTP Any FT 10 Configuration FTP oooga p Configuration FTP Any MSTP MSTP NOT SET Table 4 Available interfaces LVIS ME200 5 2 Configuring the IP 852 interface Version 3 1 Before the L Vis device can be used on a IP 852 channel the following things have to be configured in the Setup Menu of the device LOYTEC electronics GmbH L Vis User Manual 33 LOY TEC NOTE Version 3 1 IP Settings Configure the IP configuration of the L Vis device Enter the setup menu of the L Vis and configure the IP Address Net mask and Standard Gateway Reset the device when the IP configuration is finished CEA8352 configuration If required set the Escrow time Aggregation time and the MD5 key on the CEA852
36. dynamic NVs just skip this step The required data points will then be created from within the configuration software in a later step as static NVs First we need a functional block to place the new network variables in Create one of the 8 available L Vis functional blocks for example L Vis 0 to hold the two variables Next create the two switch variables For the complementary NV required to create the dynamic NV browse to the Switch object of your L Vis device and select one of the two switch variables available there the direction does not matter Version 3 1 LOYTEC electronics GmbH L Vis User Manual 16 LOY TEC NOTE Make sure to set the poll attribute to CLEAR when you create the output variable otherwise you will not be able to send out any values through this NV Also the poll attribute of the input NV should be SET so that L Vis is able to fetch an initial value when it boots up Now bind the output NV to the input NV so that we can send receive values 2 3 3 Start the L Vis Configuration Software NOTE NOTE Version 3 1 If possible run the configuration software in plug in mode from within your network management tool Open the context menu of the L Vis device block n your drawing and select Configure to start the configuration software For network management tools which do not support plug ins start the program in standalone mode and connect to your device via TCP IP or CEA709 over a LOYTEC NIC
37. electronics GmbH L Vis User Manual 82 LOY TEC top of each other the collection and the control If there are nested collections or if controls overlap on the page there may be even more layers of objects There are different ways to select a specific object in such a case Each of these methods will e Left mouse button double click moves the current selection down to the next object under the cursor in the layer stack When the bottom most control 1s reached the selection moves back to the topmost control e Middle mouse button single click does the same as the left double click e Tab key moves the selection down to the next object on the current page in the tree view From the last object on the page the selection moves back to the first object on the same page Using the tab key is especially useful while using the keyboard cursor keys to move and resize a control Using the tab key to switch the selection to the next object on the page can be convenient in this situation 8 10 Alarm Generators NOTE The alarm generator object is used to monitor input data points and issue alarms based on rules which are set on the Alarm Generator property page To add a new alarm generator use the context menu of a collection object in the object tree and select Add Alarm Generator A new alarm generator object will be created and connected to the collection object Once the alarm generator object is created connect the input data
38. for further processing Since the trend data files are actually symbolic links to a device driver you cannot directly open the files on the device Also the file size will be shown as 0 because it is not immediately known the data is generated on the fly while you are downloading it You may only download the files Some FTP client software is known to have problems processing symbolic links to files They tend to display these files as being directories but any attempt to open this directory will fail since it really is a file Examples for such programs are FileZilla and Leech FTP If you encounter this problem with your FTP client use another client or fall back to the windows explorer or the command line FTP client which is known to work as well 8 5 6 2 Operating Trend Controls Version 3 1 Trend controls do not allow data input but they can be marked selectable If the control is selectable touching it on the screen will display a vertical line at the touch point and open a data window showing the exact data which was recorded for the selected point of time The control will show the absolute date and time for the recorded data as well as the value for each of the curves displayed Each value is printed in the same color as the corresponding curve to relate the displayed numbers with the curves The vertical line may be moved around in the control by dragging it around or touching another location of the curve The data in the
39. in the button Create Server Object is used to create the new server object and the required data object s to represent it As explained before you will get two data objects if you create a server object of type value in order to be able to read and write your object 9 3 4 Remote Network Object Since there is a lot of information required to create a mapping for a remote network object such objects are usually only created from existing templates The first step therefore is to either scan the network for remote network objects or import a file to get a list of available template objects from which new client mappings may be created 9 3 4 1 CSV EDE Import Use the context menu of the file import folder and select the command Import File Browse to the CSV file you want to import and select it For BACnet models standard EDE files may be imported through this method For CEA709 models a similar file format was specified so that tools may be developed which are able to output data in a format the configuration software is able to read An example CSV file for CEA709 is installed together with the configuration software Once opened the contents of the file will be parsed and suitable data object templates will be created in the file import folder These templates are then used in a later step to create client mappings for use on the L Vis device see the section Create Mapping below 9 3 4 2 Network Scan Version 3 1 Scanni
40. in order to save space on the device For each group the entered value is stored only once even if there are more data points in the same group When done with the point and value setup switch back to the Configuration tab You should now see the list of defined value presets in a list at the top right of the window Drag and drop presets from this list into the time table area to define the desired output values throughout the day Days may be copied to other days using the Copy to button At the bottom left there is a list of all available days which consists of the seven week days which can be used to define default schedules for each day of the week plus any additional special days defined by the local calendar For the special days a priority must be assigned so that the system knows which schedule to follow on a day which is part of more than one calendar pattern The priority settings are according to the underlying network technology For CEA709 the highest priority is 0 the lowest is 126 127 is reserved for the default weekly schedules For BACnet the highest priority is 1 the lowest priority is 16 When the setup is done save the changes and exit the configuration dialog 9 4 4 Schedule Configuration Data Version 3 1 It is important to note that the configuration of the scheduler and calendar objects consists of two parts One is the point setup meaning the number of calendar patterns number of scheduler objec
41. in plug in mode during the replace procedure since the recover functions are not required LOYTEC electronics GmbH L Vis User Manual 118 LOY TEC 11 Special Functions CEA709 11 1 Binding Management NOTE NOTE When the configuration software is run in plug in mode additional functions to export import and remove the network bindings of the device are available from the Tools menu The Export Bindings function scans the database and outputs all current bindings into a text file in CSV format This file may be viewed in a text editor or spreadsheet program and used for documentation purposes or as a security backup before major changes are done to the device The Import Bindings function reads a file which was previously created by the export function or manually created in a text editor and creates all the bindings which are listed in the file If you use a network management tool with a graphic representation of your network bindings you will need to update the drawing based on the modified database so that the new bindings created by the configuration software become visible This is normally not required for object oriented tools where the new bindings immediately appear in the object tree The Remove Bindings function is not normally used but may be helpful if the network bindings of the device should be reworked completely without deleting the device itself This function is also useful for the rare cases
42. instruct the control to find the entry in the mapping table which corresponds to the current value of the control and then select the next entry to determine the new value which is sent out e Select and send previous value Similar to the above mode but the previous entry in the mapping table is selected to determine the next value Below the radio buttons is a check box which when checked causes the control to change direction when either the end of the mapping table is reached that is it switches back and forth between mode 2 and 3 walking through all available entries in the mapping table up and down LOYTEC electronics GmbH L Vis User Manual 60 LOY TEC NOTE Obviously mode 2 and 3 only make sense if a mapping table is attached to the control and the table contains at least two entries A typical use is a table with two entries and the control in mode 2 with direction change enabled This provides a simple ON OFF toggle button To build a push button which only sends out a fixed value when selected no mapping table is required Set up the control using static properties and connect the output data point which should be updated with a certain value Mark the data point to be Constant Value and enter the desired value as the Default Value of the data point 8 5 4 Numeric Control NOTE These controls are used to display values as numbers Most properties can be set on the Common Properties page as described earlier in thi
43. is used to have a vertically aligned text column even when the icons of individual items do not have the same width Even though the bitmap width parameter changes the appearance of menu items it is a property of the menu because it is the same for all items which are shown in this menu Moving an item to a different menu will show the item according to the bitmap with rule of the new menu 8 3 Menu Item Version 3 1 Menu item objects are used to build the contents of a menu They are shown in the menu in the order in which they appear in the object tree On the device each menu item becomes a selectable area of the menu which the user may select to open the page or the sub menu associated with the item LOYTEC electronics GmbH L Vis User Manual 56 LOY TEC NOTE Each item object can hold zero or more page objects and zero or one menu object as shown in the object hierarchy diagram It depends on the connected objects what will happen when the user selects the menu item This item is a return item When the user selects it the current menu will close and the parent menu will open A standard item Upon selection the menu will close and the page l None i will be shown A multi page item Upon selection the menu will close and the gt 1 eas page which was up when the item was active the last time will be shown the first page if this is the first time the item is selected The page flip actions touch gestures and pag
44. menu but this will most likely not fit the design of your other menu items so it is best to always add a setup item yourself and configure it the way you want it to look Finally add a page to the first of the two menu items This page will be displayed when the user selects the first menu item from the root menu Open the context menu of the menu item right click on the item in the tree view and select Add Page In order to see this page right after the device started make this page the projects default page Open the context menu of the page in the tree view and select Set as Default The page object is described in detail in section 8 4 2 4 5 Add Controls to the Page Version 3 1 The next step is to place some objects on the page to view and control the values of the two network variables These objects are called controls in this manual since they allow the user to control the data points and display their current value A number of different control styles are available to choose from In this example we want to display the current status of the switch input using a text control for the state and a numeric control for the value To control the switch output we use a bitmap control for the state and a bar control for the value To create the required controls either right click on the page object in the tree view and choose the control type you want from the context menu or select the page in the tree view and right click in the LC
45. more than one may be created to organize alarms into groups From the properties of the alarm server point set the Ack To Fault and or Ack To Offnormal checkboxes if the alarms from this server need to be acknowledged e Add alarm conditions to the server objects you want to monitor This can be done via the context menu of the server object using the command Create Alarm Condition e Assign one of the existing alarm servers to this condition which is done in the same dialog where the alarm condition is specified LOYTEC electronics GmbH L Vis User Manual 102 LOY TEC 9 5 2 Algorithmic Reporting CEA709 devices do currently not support the mechanism of intrinsic reporting Instead the application needs to provide an algorithm which determines if an alarm state is reached On L Vis devices the alarm generator objects described earlier in this document are used for this purpose To set up alarming using algorithmic reporting the following steps are needed e Create the alarm server point e Add alarm generator objects to your project as required e Setup the alarm generator objects Connect the input data points which should be monitored and use the alarm server point as the output point of the alarm generator 9 5 3 System Resources On BACnet devices each alarm server point automatically instantiates a notification class object to handle alarm subscriptions and notifications The object name and instance number for the obje
46. object to the control has a number of reasons The most important ones are 1 Data objects represent network objects which exist on the device They must be independent of the existence of any control or other user interface object If a data object were to be connected to a control and the control is deleted the data object would be deleted as well Using a reference object to link the control to an existing data object solves this problem Deleting the control will also delete the reference object the data point but not the data object itself 2 Many projects need to link multiple controls to the same data object for example to display a temperature which is received by a certain object from the network on a bar control and on a numeric control at the same time This would not be possible if the data object would be directly connected to a control since it could only be at one place in the object tree at a time A separate link or reference object is required which points to the data object from which the control should receive its value updates 3 Sometimes it is required to apply simple linear transformations to the data objects raw value before it can be displayed For example an object may receive a temperature value from the network in degrees Celsius but the temperature displayed on the device should show degrees Fahrenheit or a data object provides a speed in meters per second but the display should read mph or km h Such trans
47. object where global objects can be placed which are not directly related to the user interface for example alarm generators Property View On the top right of the main window is a property view which shows a number of property pages where you can adjust the properties of the currently selected object The number and kind of property pages changes according to the selected object but some of the more basic property pages are available all the time Feel free to browse through the available pages and see what you can adjust there LCD Preview To the lower right of the main window is the preview of the project as seen on the LCD when the project is downloaded This is not a functional simulation of the L Vis device but a layout guide and preview of individual menus and pages The preview changes according to the currently selected object Since the configuration software comes with a library of the layout code used in the various firmware versions of the device the preview is always accurate to the pixel Should the layout or appearance of controls change with firmware versions the configuration software is able to track these changes and display the page exactly as it will appear on the device you are currently connected to You may Select move and resize your controls directly inside the LCD preview Also there are context menus available for each control which you can open by a right click on the control in the preview The cursor keys c
48. of the values b1 and b2 b1 b2 logical inverse of the Boolean value b b returns 1 if vl is lower than v2 else returns 0 vl lt v2 returns 1 if vl is lower or equal v2 else 0 vl lt v2 returns 1 if vl equals v2 ese0O vl v2 returns 1 if vl is greater or equal v2 else 0 v1 gt v2 returns 1 if vl is greater than v2 else 0 vl gt v2 returns vt if b is true else returns vf b vt vf Reads all values from the stack converts them to Boolean values and encodes them into an integer value where the first value is used as the LSB and the last value as the MSB Returns the sine of vl where v1 is given in radians Returns the cosine of vl where vl is given in radians Returns the tangent of vl where vl is given in radians Returns the hyperbolic sine of v1 which is defined mathematically as exp v1 exp v1 2 Returns the hyperbolic cosine of v1 which is defined mathematically as exp v1 exp v1 2 Returns the hyperbolic tangent of v1 which is defined mathematically as sinh v1 cosh v1 Returns the arc sine of vl that is the value whose sine is vl Returns the arc cosine of vl that is the value in radians whose cosine is vl Returns the arc tangent of vl that is the value in radians whose tangent is v1 Returns the inverse hyperbolic sine of v1 that is the value whose hyperbolic sine is v1 LOYTEC electronics GmbH L Vis User Manual 89 LOY TEC Function acosh v1 atanh v1 gamma v
49. on Additional information shown on this page is the unique ID of the object as well as the estimated memory usage on the target device The unique ID of the object is used for identification If the object records data which is stored in a file trend log or data log the file name will include this ID in order to match the data files to the respective controls The UID is also used to reference other pages in the project action Show Page 7 6 2 Common Properties Version 3 1 The Text field is used to configure the textual part of an object This may be just ordinary text or a format string instructing the object how to format its text output For menus and items this field holds the menu or item title as t appears on the device for controls which display text or a numbers text numeric and date controls this field contains a C style format string The alignment buttons allow to adjust the alignment of the text inside the display box left middle or right aligned The font window is used to select the font for the text If other than the built in fonts are needed additional fonts can be loaded into the project using the Load button Unused fonts can be removed from the device via the Unload button LOYTEC electronics GmbH L Vis User Manual 50 LOY TEC NOTE Object Type Usage of the Text field Directly used for the menu title Directly used for the menu item text Format string which may contain one s placeholder w
50. on the device The device must be restarted once for the new settings to take effect In the configuration software the IP address or DNS name of the device can be used to establish a connection Each connection can be named and saved in a connection list which is stored in the system so that the list is available when the software is run the next time ADVANTAGES e Very fast data transfer suitable for large projects e Faster startup of the device because the project data is transferred and stored uncompressed so the device does not need to decompress the project before it can be loaded e Communication is possible even when the device is not commissioned or otherwise not reachable on the CEA709 port e No LNS or special network interface hardware is required The standard Ethernet port which is available on every PC is enough LIMITS e No connection to LNS if present and therefore no way to update the database in case the new project changes the static interface of the device Projects which add LOYTEC electronics GmbH L Vis User Manual 14 LOY TEC or remove static network variables or otherwise change the static interface may not be loaded via this method if the device s part of an LNS database since the database will be out of sync after the download and cannot be repaired by the user only the configuration software can apply the necessary changes e Any dynamic network variables which were created on the device
51. open pages after This sets a timeout after which the system resets the current access level back to 0 if no user input was detected auto logout e Go to default page after This sets a timeout after which the system will switch back to the page marked as the default page if no user input was detected 13 1 2 Timeout Values This section is used to define various time limits The meaning of them should be clear from the description of the parameter 13 1 3 System Flags The following system flags are currently available e Lock pages in setup menu If this option is checked the pages of the built in system setup menu will be protected at level 15 otherwise they will be public If the default setup menu is not used this option has no effect e Hide setup menu This option instructs the device not to add a link to the built in setup menu so that the built in setup is not accessible The user may provide customized setup pages instead matching the local language and the design of Version 3 1 LOYTEC electronics GmbH L Vis User Manual 131 LOY TEC the other pages See the section about custom setup menus earlier in this document e Disable touch gestures This option causes the touch gestures to flip pages and open the setup menu to be turned off e Ignore data point value state This is a compatibility option which will be checked automatically when an older project is loaded Turn it off to enable the new feature of tracking the s
52. or pm or a corresponding string for the current locale The time in a m or p m notation In the POSIX locale this 1s equivalent to L M S p The time in 24 hour notation H M SU For a version including the seconds see T below The number of seconds since the Epoch 1 e since 1970 01 01 00 00 00 UTC The second as a decimal number range 00 to 61 A tab character The time in 24 hour notation H M S The day of the week as a decimal range 1 to 7 Monday being 1 See also Yow The week number of the current year as a decimal number range 00 to 53 starting with the first Sunday as the first day of week 01 See also V and W The ISO 8601 1988 week number of the current year as a decimal number range 01 to 53 where week 1 is the first week that has at least 4 days in the current year and with Monday as the first day of the week See also U and W The day of the week as a decimal range 0 to 6 Sunday being 0 See also ou The week number of the current year as a decimal number range 00 to 53 starting with the first Monday as the first day of week 01 The preferred date representation for the current locale without the time The preferred time representation for the current locale without the date The year as a decimal number without a century range 00 to 99 The year as a decimal number including the century The time zone as hour offset from GMT Required to emit RFC822 conformant dates u
53. or IP 10L e Create all dynamic network variables on the device which are required for your project e Commission the device so that the dynamic NVs are created and the configuration software can communicate with the device e Run the configuration software either as a plug in on the newly created device or standalone using a TCP IP or CEA709 connection If everything worked OK the configuration software will be able to contact the device and determine model number and firmware Suitable data points will be automatically created for all LOYTEC electronics GmbH L Vis User Manual 10 1 1 2 Static NVs 108 LOYTEC dynamic NVs present on the device If you have communication problems an error message will be displayed and the procedure cannot continue until communication is possible Load the project which was already prepared or design a new project If a prepared project is loaded the contained dynamic NV data points will be synchronized with the existing data points based on the NV name direction and type If there are any data points which cannot be assigned automatically a dialog for manual assignment will be displayed Now download the project to the device The device will restart and activate the new project It is now ready to use Projects using static NVs have the advantage that they do not require the network management to support dynamic NVs Also it is possible for such projects to run in a special mode where th
54. poll on system start features Add network variable s x Warable name rl Value Direction Output Input Cancel Poll attribute Clear Same as source NW Help C Set Opposite of source Ny Humber to create li Start rank o M Remove array subscripts Figure 13 Add network variable dialog This finished the creation of the dynamic network variable and shows the window which allows to bind the dynamic network variable to the complementary network variable Figure 14 Version 3 1 LOYTEC electronics GmbH L Vis User Manual 124 LOYTEC BAL Lon workec Manager L ISTest mn nn Took Phage Lar Help os Sem aT aoe S io m nt wel PETT TIA IE FIT ES A E Projet A aiki emege FHEA Hon LaTe 5 Laratinna a ABE Levis LA dd Sla ielat 4 Liat al Interface D ls Frl Taken i Enaneriicaa p Senior AE Insel a Mode Object 0 red Loop bento 1 mutuo Remove Memmest Memos Menowest er SS aC Era Fieles court Defoe Fiepeal lives Detna FF dudhenticated F Piney Trenink tine Det Brosdensting f Mewa 1 Grou f Elan Ureghacla Selector corfkcls 1 Urecast OU deln 2 25 5020 IE DIT SF OOOO me NS ft Eine Assn 3 ello Cam J Tso Readr E IN Inn Advanced 02 09 2008 ar Figure 14 Network variable connection window 11 4 3 Alex To create dynamic network variables in Alex add the L Vis device to your project Sel
55. precision 1s missing 6 digits are given if the precision is zero it is treated as 1 Style e is used if the exponent from its conversion is less than 4 or greater than or equal to the precision Trailing zeros are removed from the fractional part of the result a decimal point appears only if it is followed by at least one digit The argument is expected to be a text string If a precision is specified no more characters than the number specified are written A is written No argument is converted in the process 16 2 Date format strings Version 3 1 The format string used by L Vis date controls is equivalent to the format string used by the ANSI C function strftime The locale setting on the L Vis device for the purpose of formatting dates is fixed to U S setting therefore the names of weekdays and months will be in English language only Conversion specifiers are introduced by a character and are replaced as follows a A ob B Yc HC HC od D e E G 08 h H I vo The abbreviated weekday name The full weekday name The abbreviated month name The full month name The date and time in American writing The century number year 100 as a 2 digit integer SU The century number the year divided by 100 and truncated to an integer The day of the month as a decimal number range 01 to 31 Equivalent to m d y Like d the day of the month as a decimal number
56. reason why the NVs or the bindings could not be restored possibly checking the Binding Report which is available from the View menu for errors then try to use the Recover DynNVs and Recover Bindings functions from the Tools menu to first restore the dynamic NVs if any and then restore the bindings e Revert back to the last working setup by removing the device from the network database and roll back the device configuration by following one of the procedures for integration of a new device but using the last working project While doing this do not run the configuration software in plug in mode at any time Also skip the step of manually creating dynamic NVs if instructed to do so by the standard procedure If the old project actually used dynamic NV data points these will be reported as unusable Delete them from the project and continue Once the device is re integrated recover the dynamic NVs if any and the bindings as described above If dynamic NVs were recovered the project needs to be loaded again so that the NVs can be used LOYTEC electronics GmbH L Vis User Manual 117 LOY TEC NOTE Version 3 1 Reverting back to the last working setup is much easier if a backup of the database is available In this case first restore the database from the backup and then simply follow the appropriate procedure for device replacement using the last working project file In this case the configuration software may also be used
57. section 9 3 4 3 Create Mapping Browse through the available points in the import folder and select the data points for which mappings should be created Multi selection within the same folder is possible Then open the context menu and select Use on Device For all selected points a suitable remote data object will be created Version 3 1 LOYTEC electronics GmbH L Vis User Manual 97 LOYTEC NOTE NOTE The data direction of the points created in the import folder are set from the point of view of the scanned device since they represent data objects which are available on the remote device for a network variable input on a remote device you will see an input data object in the import folder Once the point is used to create a remote network object on the L Vis device the direction will change since a network variable output will be required to send data to the remote devices network variable input To s mplify the selection and configuration of remote network objects for CEA709 devices it is possible to create one device configuration template for the different program IDs The device template defines a set of network variable objects and their configuration which can be used as a template when a device of the specified type s added to the project To add new network variables to the device template select the desired imported points from the import folder and select the context menu command Use as Template to add them to
58. software may then be run in either mode The recommended procedure to replace a device using dynamic NVs is as follows e Physically replace the device in your network the new device still being empty that is no project is loaded yet e Execute the standard replacement procedure of your network management tool and use the already existing device template which was installed by the configuration software This is the same template as used to originally integrate the device since the device does not change its static interface in such a setup e After the replacement make sure that the device is commissioned so that the dynamic NVs are created on the device e Run the configuration software either in plug in mode or in standalone mode load the project from the file and program it into the device e The device restarts and 1s ready to use 10 2 2 Static NV Projects A device with a project using static NVs only is easy to replace if it is possible to connect the new device to an IP network for programming purposes Here is the recommended procedure Version 3 1 LOYTEC electronics GmbH L Vis User Manual 111 LOY TEC NOTE e Connect to the new device in standalone mode using a TCP IP connection requires to set up the IP settings for the new device e Make sure the device is empty and remove any existing project if required This can be done through the configuration software using the command Remove Configuration from the
59. the bar and the transparent background color for the container and the frame Now you can prepare a page background showing a sunblind which is completely rolled down Place the bar in front of this image and you are able to cover up parts of the sunblind with the solid bar color making it look like the sunblind is going up and down If you switch color assignments you can use the moving bar to selectively uncover parts of the background Example 2 In front of the above window showing the moving sunblind a completely transparent bar control may be placed both bar color and container color are set to the transparent background By connecting an output data point to this control it becomes selectable and accepts user input Now the user may touch any position on the window which will result in a value update on the output data point This value may now be used as a position indicator and the sunblind may be moved to the indicated position automatically without the user keeping a down or up button pressed all the time The static sunblind image in the background may be replaced by a bitmap control with a mapping table to show the current rotation of the sunblind 8 5 6 Trend Control Version 3 1 Trend controls record and display data point values over time This type of control does not allow inputting new values and therefore can not handle output data points Only input data points may be connected to a trend control On the device th
60. the real value will be shown that is a limited value axis does not affect the actual data which is recorded Table 14 Color assignment for trend curves Apart from the colors and the font for the scale which can be set on the Common Properties page all other properties are set on the Trend Control property page This page 1s divided in 4 sections which are described below On the top left the Value Axis can be configured Set the desired Range for this axis and enable or disable the Tick Marks and or the Scale Labels On the top right the Time Axis 1s configured Select a suitable Time Span which is given in time per page For example if you set this to one hour per page the graph will show the values of the last hour together on one page To keep older data as well which is not visible on the first page because it is older than the given time span set the desired amount of History Buffer that should be used LOYTEC electronics GmbH L Vis User Manual 64 LOY TEC NOTE Version 3 1 by this control This value is given in pages that is if you set the time span to one hour and configure one history page the control will store the values of the last two hours Older data will be overwritten by new data After setting the size time span and history buffer check the resulting size of the required data sample buffer at the bottom of the property page The memory requirements can get significant if you use a larger number of su
61. the scale Color configuration is done as usual on the Color property page The following colors are supported by bar controls Element to which the color applies Numbers of the scale Frame drawn around the entire control if the control is selected Tick marks and the bar frame as described above Bar which represents the value This color may be overridden by color Bar Bitmap i i specifications from a connected mapping table Empty space inside the bar frame which is currently not filled by the bar color Backorounid Color of the background outside the bar frame If the transparent check S box is set all pixels using this color will be transparent p Table 12 Color assignment for bar controls All other properties are set on the Bar Graph property page The most important property on this page is the Value Range of the bar It must be adjusted to match the actual value range you want to visualize If the bar is used to input values this range also defines what the user may enter Values outside the given value range cannot be entered even using the key pad which is optionally available for input bar controls LOYTEC electronics GmbH L Vis User Manual 62 LOY TEC NOTE NOTE Set the desired value range before you determine size and position of the bar especially if tick marks and or a scale is to be drawn This is important since the scale which best fits the current size will be determined and drawn as
62. there is no bitmap to display the size can be set manually and the bitmap controls area will be empty with just a frame drawn around it in the selected frame color Bitmap controls without any bitmap and with the frame color set to the transparent background color are often used to define clickable areas on a page which uses a background graphic In this case the pages background already provides the graphic representation of buttons lamps building floors or other elements which should be selectable by the user Using empty transparent bitmap controls rectangular regions may be defined on the page which the user may select The control itself usually has an action connected to it to Jump to a new page or update a data point The following colors may be set for bitmap controls on the Color property page Element to which the color applies Color of the frame which is drawn if no bitmap was assigned or color in Bar Bitmap which a monochrome bitmap is drawn May be overridden by colors from the mapping table For color bitmaps this color definition is ignored Frame drawn around the text if the control is selected Also used to draw the Selection grid of the drop down list from which a new text element is chosen input controls only Color of the controls background if no bitmap is shown Otherwise this is Background the color which should be considered the background of the graphic If the transparent check box is set all pixels
63. to add as many data record layouts as needed and define a trigger condition for each of the data records individually To work on the layout of a specific data record first select the record in the tree view to make it visible in the LCD preview You can then continue to work on the record in the LCD view Properties specific to the data log control are configured on the Data Log Control page The options currently allow to define if the control should save the recorded data in persistent memory how often it should save the data and the total number of records to save when this number is reached older data is overwritten with newer data It is also possible to enable or disable the navigation bar at the bottom of the control and set the size of the buttons As with trend log controls the recorded data 1s available in CSV format for download via FTP See the section about trend data access for detailed information about the retrieval of this data from the device The following colors may be set for data log controls on the Color property page Color Name Element to which the color applies Linel Highlight color of 3D frames Line2 Shadow color of 3D frames Line3 Grid lines between data records Selection Frame drawn around the entire control if the control is selected Bar Bitmap Button graphics Color of the background If the transparent check box is set all pixels using this color will be transparent Background Table
64. to ease processing on the PC The files may be downloaded from the device using an FTP connection User name and password for the FTP account can be set in the project settings option Data Access There are two locations to access the CSV data One location s intended for access by a human user the other one is intended for automated tools e data trend This is the location intended for access by a human user The file name consists of the object name of the control as seen on the tree view and the unique ID of the control as displayed on the General property page This allows the user to easily identify the data file belonging to a certain control on the device e data uid trend This is the location intended for access by automated tools The filename consists only of the unique ID of the control This allows an automated tool to easily construct a list of files to access independent of the name of the control which may not be known and which may change Example A project contains a trend control with UID 0x122114B1 and name Trend 1 The data recorded by this control will be accessible in CSV format under the following file names on the device data trend Trend 1 122114Bl csv data uid trend 122114B1 csv Spaces in the object name are replaced by underscores to avoid file names containing spaces which may be a problem for some FTP clients LOYTEC electronics GmbH L Vis User Manual 66 LOY TEC NOTE NOTE
65. to make sure that a project can be used on any PC is to store all custom fonts which are used in the project in the same place where the project file itself is located For example create a folder to store the project file together with all custom font files in one place Now the entire folder may be copied to any other PC and the required font files will always be found automatically 13 11 2 Font Recoding Version 3 1 The L Vis configuration software as well as the L Vis device itself are Unicode enabled All text entered in the configuration software and displayed on the device is encoded using the 16 bit international Unicode standard UCS 16 PCF and BFD fonts may use other encodings such as ISO8859 JISX0212 Big5 IBM or Microsoft codepages for example LOYTEC electronics GmbH L Vis User Manual 139 LOY TEC NOTE MS CP1250 If such a font is loaded it 1s automatically recoded to UCS 16 before it s used since the L Vis device does not recognize encodings other than UCS 16 The font recoding is done using the coding tables found in the directory Encodings located in the program directory New encodings may be added to make them available for the import of fonts Fonts in other formats than BDF or PCF should contain an ISO8859 1 or ISO10646 Unicode codepage or Adobe Type 1 glyph names in order to facilitate recoding to UCS 16 While there are practically no vector fonts which do not provide any of this information it may be
66. used by the specialized controls on the device to edit schedules calendars or display alarm lists A set of translations may be given a name in the Preset field which can then be saved using the Add button The translation is then stored on the system and will be available in the Preset dropdown list for re use in other projects Version 3 1 LOYTEC electronics GmbH L Vis User Manual 133 LOY TEC 13 1 12 Mail Account NOTE Pressing the button Setup Mail Account opens a dialog to configure the SMTP mail account used to deliver E Mails To use the mail feature the following conditions must be met e The device must be connected to a TCP IP network and must be able to communicate with the desired SMTP server In many cases this server will be outside of the current subnet Therefore it is important that the gateway address and the network mask settings on the L Vis are correct e At least one DNS server address must be set on the L Vis device if the SMTP server 1s given as a DNS name which 1s usually the case e In the mail account configuration dialog the master enable checkbox must be set and a name or IP address of an SMTP server must be entered e It is desirable to use some form of time synchronization on the L Vis device in order to provide correct time stamps when building and delivering mails Some mail clients tend to sort incoming mails by origin date not date of reception which could cause confusion if the date and
67. using this color will be transparent Table 11 Color assignment for bitmap controls In the VGA palette there is one color middle grey defined at two different color indices index 7 and index 248 meaning that this color appears twice in the palette Graphic elements using transparency may use one of the two colors 248 to fill all areas which should later be transparent and still have the same color available for use in the bitmap 7 If you use any other color for example black at index 0 you can no longer have black pixels in your graphic since all pixels drawn with this color will be transparent so you loose a color 8 5 3 Push Button Version 3 1 Push buttons are not provided as a specialized control object type but are implemented by a special mode of operation which can be activated for text controls and for bitmap controls to create push buttons showing text or graphic elements using all the features of these controls Push button mode is activated on the Text Bitmap property page using the Enable Push Button Mode check box Once enabled the mode of operation is selected on the right via three radio buttons The options are e Send current value In this mode each press of the button will cause all connected output data points to be updated with the current value of the control The current value is defined by the last value received from any of the connected controls e Select and send next value This mode will
68. which require some knowledge of how these scheduler objects work internally Therefore the configuration software provides the following mechanisms to help in choosing the right settings e Current resource usage The absolute minimum settings required by the current project are shown in a table at the left side of the window This data may be used to fill in the values at the right side but some additional resources should be planned to allow for configuration changes which need more resources e Auto Set This button may be used to let the configuration software decide on the best settings to use based on the current project Since the current projects resource usage 1s taken as a starting point all schedulers and calendar patterns in the project should first be configured as required before this button is used e Set Defaults This button will choose standard values for all settings In most cases these settings will provide more resources than necessary It is possible to enter anything here until the project is actually saved or downloaded At this point in time the software will check that the resources configured here are sufficient to support the projects configuration If this is not the case this dialog will automatically open so that the settings may be adjusted 9 4 6 Resource allocation Version 3 1 On BACnet devices there is always a direct assignment between a local scheduler point and a server object because the two
69. without using a PIN code For security reasons it is possible to change the PIN code for each level by writing the new PIN code to the respective PIN code Set register There 1s one register for each of the access levels 1 through 15 The new PIN codes will be stored on the device and remain in effect until a new project is loaded with a special option set telling the device to reset its PIN codes to the values stored in the project 13 3 Undo Redo NOTE The current version of the configuration software provides a simple form of undo and redo To make use of this feature 1t is required to take a snapshot of the project from time to time by pressing the Snapshot button in the tool bar using the Snapshot command from the Edit menu or the keyboard shortcut Ctrl A Typically a snapshot will be taken before major changes are done to the project Once there is at least one snapshot in the internal snapshot buffer the undo and redo functions become available Using the Undo function the project can be restored to the previous state Using Redo the project can be restored to the next state the state it was in before undo was executed With multiple snapshots of the project in the buffer it is possible to move back and forth between the individual versions without having to save each of these versions to a temporary file on the PC The software will keep the last 32 snapshots removing older snapshots when new snapshots are taken The
70. would also be possible to add further icons to the taskbar which open other pages Also icons which are only displayed when an alarm occurs could be added 15 1 4 Bitmap Menu The bitmap menu shows a navigation using full screen bitmaps with touch sensitive zones On the main page the Floor 1 can be selected and on the floor page the upper left room The back button brings the user one level back Version 3 1 LOYTEC electronics GmbH L Vis User Manual 154 LOYTEC i Menu_exomple 1 L Yis Configuration File Edit Mandel Firmware View Help DEU RBB tS HTXx Text Control Root Menu Bitmap Menu Tower Overview Moor kext Slalu valing dala DE Usage Root Menu lab Menus amp Icon Menu Ga Taskbar Eilmap Menu Tower Overview HFG Rack Tron Floor 1 Selection T Flour Lex 4 Floor 2 Selection iT Floor bext 41 Floor J Selection Hoor Plan Rua Paye fa Setup Item 3 Global Objects For Help press Fl 15 2 Light Control General Common Propsites Mapping Data Point Color Text Ditmap Screen Coordinates Let 1 width 39 F Auto Resize Tup las Hegh WW Resize Has Bilmap Text j 1 E Font 0600 01 Froed A r ROM font 256 glyphs rn Sees Z a ui ij A 1 Ee Panne ee Terre ee P7 bia i J r F 1 1 a ere oe ill W Elan 1 pri ai PE A Rae cio A ers Items 9 networks under control Menus 2 Pages 15 Controls 140 Detapoints
71. you resize the control Depending on the value range the space requirement of the scale and the optimum size of the bar will vary The Flags below the value range control which components are drawn and how they are drawn The flags are pretty self explanatory if you consider the naming of the individual components of the control as outlined above The flag Numeric Input Panel enables the display of the numeric keypad when the bar enters input mode It is then possible to either drag the bar as usual or enter an exact value on the keypad The keypad will be positioned on the screen so as to not overlap with the bar if at all possible As you may have noticed not all of the bar controls elements can actually be disabled In particular there is no flag to disable the bar frame If the bar graph is used in an application where the frame is not wanted it can still be made invisible Select the same color for the bar frame as you selected for the background and check the Transparent box The frame will now be transparent 8 5 5 1 Special Application Hints NOTE A powerful way to use bar controls 1s provided by colors and transparency By disabling all the decoration around the actual bar it is possible to have a rectangular area on the screen which can be filled with a color or made transparent depending on the value of a data point This provides an easy way to selectively hide certain areas of the screen Example 1 Define a solid color for
72. you to press to either close and accept the new value or close and restore the previous value Leaving a control idle while in input mode will usually be interpreted by the control as a cancel action The control will then leave input mode return the focus to the page and LOYTEC electronics GmbH L Vis User Manual 37 LOY TEC restore the value t had when input mode was entered The idle timeout can be set in the Project Settings dialog together with a number of other timeout values 6 2 1 Schedule Control NOTE This section describes how to operate a schedule control A schedule control displays the configuration of one or more local or remote scheduler units The control consists of three basic areas e Header The header displays the name and the effective period of the selected scheduler If there is more than one scheduler configuration available more than one scheduler data point is connected to the control a small triangle is drawn next to the schedule name and touching the name opens a dropdown list of all available schedules e Day List The left side of the control contains a list of days for which schedules are available There is one entry for each day of the week followed by the list of all exception days defined by the corresponding calendar e Time Table The right side of the control shows the time table for the selected day The time table starts with its own header line which shows the selected day and also
73. zero padded For d i 0 u x X a A e E f F g and G conversions the converted value is padded on the left with zeros rather than blanks If the 0 and flags both appear the 0 flag is ignored If a precision is given with a numeric conversion d i 0 u x and X the 0 flag is ignored For other conversions the behavior is undefined The converted value is to be left adjusted on the field boundary The default is right justification Except for n conversions the converted value is padded on the right with blanks rather than on the left with blanks or zeros A overrides a 0 if both are given LOYTEC electronics GmbH L Vis User Manual 160 LOY TEC gt a space A blank should be left before a positive number or empty string produced by a signed conversion A sign or always be placed before a number produced by a signed conversion By default a sign is used only for negative numbers A overrides a space if both are used 16 1 2 Field Width An optional decimal digit string with nonzero first digit specifying a minimum field width If the converted value has fewer characters than the field width t will be padded with spaces on the left or right if the left adjustment flag has been given A negative field width is taken as a flag followed by a positive field width In no case does a non existent or small field width cause truncation of a field if the result of a conversion is wider than
74. 1 a Netzwerkvariablen 13 Funktionsecinheit on 13 Y Virtuelle Funktionseinheiten 1 DB vrs A Netzwerkvariablen 1 ME 6 Parameter 0 Qy verbindungen 0 D Swtch Router 0 Js Untersysteme 0 E Kan le 1 Y Gerstevorlagen 5 amp Verbindungsvorlagen 1 3 Munitursets 0 LVI5D eo la Onbel 01 03 2004 12 13 Figure 19 Finished creation of new network variable Version 3 1 LOYTEC electronics GmbH L Vis User Manual 127 LOYTEC 11 5 Built in LONMARK Objects The CEA709 models of L Vis provide a number of static function blocks which are available for use even when no project is loaded These blocks are described in the following sections 11 5 1 Timer Object The timer object implements a LONMARK Real Time Keeper object according to the LONMARK Functional Profile 3300 It sends out the current time in the nvoDateTime network variable of type SNVT time stamp The object is configured using the standard configuration properties e SCPTmanualAllowed e SCPTmasterSlave e SCPTobjMajVer e SCPTobjMinVer e SCPTsummerTime e SCPTupdateRate e SCPTwinterTime The configuration properties are defined in the LONMARK functional Profile 3300 document 11 5 2 Switch Object Version 3 1 The switch object implements a LONMARK Switch object according to the LONMARK Function Profile 3200 It sends out an nvoSwitch network variable of type SNVT_ switch and receives a fee
75. 1 abs v1 Version 3 1 Return Value Returns the inverse hyperbolic cosine of v1 that is the value whose hyperbolic cosine is vl Returns the inverse hyperbolic tangent of v1 that is the value whose hyperbolic tangent is vl Returns the value of the Gamma function for the argument v1 The Gamma function is defined by Gamma x integral from 0 to infinity of t x 1 e t dt It is defined for every real number except for no positive integers For nonnegative integral m one has Gamma m 1 m and more generally for all x Gamma x 1 x Gamma x For x lt 0 5 one can use Gamma x Gamma 1 x PI sin PI x computes the absolute value of the argument vl LOYTEC electronics GmbH L Vis User Manual 90 LOY TEC 9 Data Point Management 9 1 Concept NOTE Version 3 1 As outlined in the description of the data point object in section 8 6 the network variables BACnet server objects client mappings user defined registers and system parameters are represented by objects which exist on the device independent of any controls or other objects in the object tree These data objects are then referenced from the data point objects in the tree by their unique ID While some of these objects are created automatically most of the data objects need to be created by the user There are ways to manually create individual data objects import object definitions from CSV files or scan the network and create new data objects based on
76. 1 LOY TEC NOTE Version 3 1 end of the bar to make it look like a thermometer In this configuration the bar control consists of the following elements e Scale The numbers on one side of the bar which are evenly spaced out and calculated to be easy to read While resizing the bar in the LCD preview the scale is constantly updated to show the most suitable scale for the given value range and size e Tick Marks These are the small indicators next to the bar They are calculated automatically to be evenly spaced out while representing a round step value between two tick marks If the scale is disabled the tick marks may be much closer to each other e Dot At the lower end of the bar a dot symbolizes a thermometer e Frame The actual bar which displays the current value has a one pixel wide frame around it e Bar Inside the frame is the bar which actually shows the current value With increasing values the bar moves up or to the right Position and size of a bar control as defined on the common properties page correspond to the frame of the bar control as described above It does not correspond to the selection frame drawn around the whole bar control To move a bar control in the LCD preview you must grab it somewhere inside the bar frame not outside like the scale or tick marks To resize the bar use the lower right hand corner of the bar frame On the Common Properties page a font may be selected to be used for
77. 16 Color assignment for data log controls 8 5 9 Schedule Control Version 3 1 The schedule control is a specialized control to serve as a schedule configuration editor for local and remote scheduler objects It is possible to connect more than one scheduler data point to the same control In this case the title line will allow the user to select the schedule which he wants to view or edit Refer to section 6 2 1 for details about operating a schedule control on the running L Vis device For this type of control it is usually required to load a user defined font The smallest built in font is too small to operate the control on the LCD and the medium size built in font is too wide to be useful for many applications Therefore the configuration software automatically searches the list of loaded fonts for a suitable font and if none was found automatically loads a font which should be a good choice to get started A specific font may be selected or loaded any time on the Common Properties page LOYTEC electronics GmbH L Vis User Manual 69 LOYTEC 8 5 9 1 Schedule Control Properties Version 3 1 The properties to set on the Schedule Control property page define the basic appearance of the control and control access to various operations which modify configuration data If a local scheduler data point is connected to the control its configuration will be shown in the preview as well If more than one local scheduler point is connect
78. 16 Size S711 Figure 36 Bitmap menu configuration The project Solution examples manual lcp contains a Switch Demo page i Solution_examples_manual 1 L Yis Configuration File Edt Model Firmware Yiew Help Cae ar 22913 Subsystem L L VIS ONNET Page Hoot Menu Example Pages f Switch Example Root Menu Menu Nawigal iorn Example Pages 9 Switch Example 410 Light Value PHI Dimm up 4 Laren down HY Switch Niman Back Icon Sunblind Pacample Animation Example Split Prample Counter Demo Setup Menu j Soba Objects General Common Properties Mapping Data Point Color Menu Page Page Rout Meru Example Pages Swlch Example Color Schere Color Arsigrenenk Tem X Framertsis X Selection X C Apply to all eubobjecte Lmel X Barmen gt lt Apply to all objects of thes type Line2 X Container gt lt Line X Backgourd Fxecate Controls 44 Datapoints 41 Size 1344 Pages 6 Menus 1 Items 3 Figure 37 Switch demo page The example uses a bitmap control in push button mode to switch the state of a SNVT_ switch on or off Two arrows allow to increase and decrease the value part of the SNVT_ switch variable To increase and decrease the values action controls are assigned to Version 3 1 LOYTEC electronics GmbH L Vis User Manual 155 LOY TEC the bitmap controls The increase and decrease operations are executed by two mathemat
79. 1s shown in the source list There are two special variable names which may be used in a placeholder string The special variable name mailid will be replaced by the unique mail ID the variable timestamp will be replaced by the date and time the email was sent Both placeholder strings can be inserted automatically using the dropdown box and the Paste to Text button 9 8 2 E Mail Trigger Version 3 1 This tab is used to configure automatic mail sending based on the value of certain data points If nothing is configured here the mail may still be sent using an action object in the L Vis project please refer to section 8 8 for a description of action objects To send the mail based on the value or state of a data point follow these steps e Add the desired data point using the Add button Valid data points to use for mail triggers are normal analog binary and multistate values as well as alarm server and client points e Depending on the type of data point select the conditions which should trigger this mail Normal data points can trigger on the current value zero or non zero as well as the state invalid or offline alarm data points can trigger the mail based on various alarm types and or state transitions LOYTEC electronics GmbH L Vis User Manual 106 LOY TEC e Repeat for additional data points if the mail should be triggered by more than one source In case of multiple mail triggers the mail is sent if any of the con
80. 2 Dynamic NV Change Version 3 1 If the project change includes the addition or removal of dynamic NVs without any changes to static NVs the following procedure is recommended LOYTEC electronics GmbH L Vis User Manual 113 LOYTEC Execute all required changes to the dynamic NV interface using your network management software This includes adding new NVs and removing old NVs as required Once the required changes were made start the configuration software or 1f it is already running use the Update Data Points button from the tool bar to read the new set of available dynamic NVs from the device The configuration software may run in either mode for this type of configuration change Load the project and modify it as required If the project still uses some of the dynamic NVs which were removed in the first step these will be reported and may be replaced by other data points or may be deleted all together Do not replace them with static NVs since this would mean a change of the static interface which implies a different procedure Download the modified project TCP IP is preferred due to its speed The device will restart and be ready to use 10 3 3 Static NV Change For project changes which result in a change of the static NV configuration certain restrictions apply regarding the way such changes may be performed There are two possible ways to perform such a change The automatic and recommended way is to run the configur
81. 40 bitmap would appear as a vertical bar at the Page left Please note that a page requires an additional 78kB of memory as soon as a background bitmap is loaded independent of the bitmap size To place smaller static bitmaps anywhere on a page use a bitmap control and assign the bitmap to the control instead of the page then move the control to the position where the graphic should be located Bitmap to show when the control is created If the control does not have a mapping table attached to it this is the only image which is shown by the control It is then similar to a text control containing static text Bitmap controls may be used in this way to place logos or other graphic elements Bitmap Control anywhere on the screen If a mapping table and a data point is attached to the control the images from the mapping table may replace the image specified here when new values are received or selected by the user Table 6 Usage of the common bitmap for visible objects On the right side of the property page the access level required for data input can be specified if the selected object is an input control The access level must be equal to or higher than the level specified here otherwise the user will see the control but will not be able to select it and input new data The button called Set as Default may be used to save the design of the currently selected visible object as the default design for new objects of the same type If
82. 709 device may have an impact on the integration of the device in your network The configuration software will automatically determine if your changes need special attention and warn you if the required modifications can not be made automatically Refer to the chapter Connecting to the Device for more information about this topic To create a new static NV select the folder named Local NVs and use the New button or the context menu to add a new data object A new dialog will open and request the required information to create the new NV which is LOYTEC electronics GmbH L Vis User Manual 94 LOY TEC e Datapoint Name Enter a name for the data object If this s left blank the data objects name will be derived from the programmatic name of the network variable e Programmatic Name The programmatic name of the network variable on the device There are certain restrictions to this name which originate from the underlying network technology For example the name may not exceed 15 characters Also the name should start with the prefix nvi or nvo If this 1s not the case a Suitable prefix will be added to the name automatically depending on the selected direction e Resource File This dropdown list contains all resource files currently installed on the system Select the desired resource file which contains the data type you want to create The standard network variable types SNVT_xxx are defined in the resource file called STANDARD
83. 709 networks The L Vis configuration software can be run as a standalone program as well as an LNS plug in and supports the use of both static and dynamic network variables in a project to allow easy integration in any kind of CEA709 network The key features of the L Vis device family are e LCD display with a resolution of 320x240 pixel 256 colors VGA Palette dimmable CFL backlight and a touch screen e Simple graphical programming via the supplied configuration software e Support for alarming scheduling and trending e Support for the UCS 16 character set of the Unicode standard ISO 10646 to allow for the design of projects in any language including Chinese Japanese and Korean CJK e Display of data as numeric value user defined text or graphic elements horizontal and vertical bars or trend logs A special element s available to display date and time in form of digital or analog clocks LOYTEC electronics GmbH L Vis User Manual Version 3 1 10 LOYTEC Input of data via a numeric keypad direct drag of a bar or selection from a dropdown list of texts or graphic elements Mapping of values to colors to allow an element to change color depending on the current value Supports layers and transparency for all display elements Layering is simply defined by the order of objects n the tree view which may be changed easily by moving the objects around as required Support for numeric operations on data p
84. D preview area to reach the same context menu Add one text control one bitmap control one numeric and one bar control to your page Now place the controls on your page so that they do not overlap each other Grab and drag them with the mouse or enter position and size in the Screen Coordinates section of the Common Properties page To resize the controls with the mouse move the pointer to the lower right corner of the controls area in which the value is displayed that is disregard any decorations around the value area like the scale of a bar control For most control types the value area fills the entire space of the control except for the selection frame For more complex controls like bars and trend logs you can view the value area by changing the Container color on the Color property page Then grab the control at the lower right corner of the container area LOYTEC electronics GmbH L Vis User Manual 23 LOY TEC NOTE The position and size you set on the Common Properties page also refers to the value area of the control not to the selection frame around it This is done so that for example the width and height of a bar does not change when you enable or disable tick marks or scale These are just seen as decoration which can be turned on and off while the area of the value display remains stable Adjust the properties of each control as you like or leave them at the defaults which should be fine for this demo Bitmaps will be ad
85. EC 4 Electrical Installation 4 1 Connection diagram For information about unit installation please refer to the connection diagram delivered with the unit which is also available for download from the LOYTEC website 4 2 Electrical Characteristics The electrical characteristics are shown in Table 1 Table 1 Electrical characteristics 4 3 Touch Panel Cleaning Instructions Clean and soft clothes with neutral detergent or with ethanol may be used for cleaning Do not use any chemical solvent acidic or alkali solution Version 3 1 LOYTEC electronics GmbH L Vis User Manual 29 LOY TEC 4 4 Terminals and Jumpers All connectors and configuration jumpers are accessible from the rear of the device The following connectors are available LVIS 3E100 Select IP 852 The unit can be operated on an IP 852 IP 10 channel as well as on an or FT 10 channel first FT 10 or LPT 10 channel BIP or MSTP for BACnet devices The LVIS ME200 Select BIP or jumper labeled FT IP or BIP MSTP distinguishes between the 2 modes MIST P mode first of operation Please set Jumper in order to operate the device on an IP 852 or BIP channel IP mode and remove the Jumper in order to operate the device on an FT 10 LPT 10 or MSTP channel Connect the Earth Ground Power is connected to the 3 position terminal labeled POWER Please wire to the earth ground stud use only power supplies with the characteristics shown in Table 1 Connect earth ground
86. Figure 34 QAQ Forward Por Hei premi FL Pei bea AE Figure 34 Icon menu On an empty page as set of bitmap controls is placed Each bitmap represents a page or a submenu In the example a text control is placed below each bitmap icon An action object which executes a switch to a linked page is assigned to each bitmap control On the bottom of the example page three additional bitmaps are placed which have action assigned to switch pages back and forth and to open the system menu Version 3 1 LOYTEC electronics GmbH L Vis User Manual 153 LOYTEC Using the icon menus it is also possible to implement the whole navigation without the default menu In that case the main menu page should have the checked the default page checkbox in the Menu Page tab 15 1 3 Taskbar Menu To simulate a PC environment a system with a setup with a task bar can be created Figure 35 Ps E Pod Presas fa itp Co i it Gere Larson psie spe Pas Pod Cota Test Ei Ta toe Coonan waf t ee bo Maras hio El Ip 7 ia 3 Tos Ti 4 fatter Ook tegen hee i Iep en Figure 35 Taskbar menu The taskbar is formed by a bitmap control The bitmap for the menu button is placed on top of the taskbar bitmap An action object is assigned to the menu button bitmap This action object opens the main menu In the example a date control which displays the current time is placed on the task bar It
87. ON in the value list and select the bitmap for the ON state The configuration now looks similar to Figure 21 The project can now be loaded into the L Vis device For Heap pre Fl i Users Mara 101 1 L VWis Configuration Ele QE Model Fires per ep ek A Ba Er Ores Usage Ge Common Prop ape Deia Port Colo Teri Bitmap x aw Um a egl A AOO O OOOO OO Figure 21 SNVT_switch on a bitmap control 14 1 3 Numeric Control A numeric control is used whenever a data point needs a continuous numerical output or input like a percentage value or a temperature value This example shows how to use a SNVT switch together with a numeric control The state element of the SNVT switch network variable is fixed to 1 whereas the value part can be set between 0 and 100 Version 3 1 Add a numeric control to the page Add data points to the control To do this select Add Data Point from the context menu of the control Add an input data point for nviSwitch value and output data points for nvoSwitch state and nvoSwitch value A default mapping between the state input values and the displayed text is automatically added to the control For the input data point nviSwitch value set the System Startup flag on the Data Point configuration tab For the nvoSwitch state data point go to the Data Point configuration tab configure the Default Value to 1 and set the Constant Value flag Set the NV Update Flags valu
88. Object 0 Virtual Functional Block Selected Object subsystem 1 SensoriClosed Loop Sensor nvo0l1 Value Find Figure 9 Select complementary variable dialog Now the source NV name in the Create Network Variable dialog 1s filled in Figure 10 NOTE Make sure to set the poll attribute of the NV to Set if you are creating an input NV in order to allow the device to support the receive timeout and poll on system start features When Finished press the OK button and also confirm the Choose a Network Variable dialog with OK Version 3 1 LOYTEC electronics GmbH L Vis User Manual 122 LOYTEC Wewe bw Mame nYiswritch JR Howe many 1 Cancel Help Member lt Undetined gt Source Mi Subsystem 1 Sensor Closed Loop Sensoar nyvo0 value Direction Output Poll Attribute of newe NYS e Clear C Same as source Ww C Set Opposite of source Wiw Figure 10 Create network variable dialog This completes the creation of the new dynamic network variable Figure 11 The dynamic network variable can now be bound to other network variables like a normal network variable and can also be used as a data point source or data point sink in the L Vis configuration software Airborne bh ak ehe 1 E lf Sl ge at es pei Pym pok gge joniske ika kep j gt A sim DJU Ewa Ardo gt E D amp D ala gt io af De Das Ear Ae Oe eG HA He Closed Loop Actuato Closed Loop Sensor wath 0
89. ZE O10 ATTENTION 3 NORMAL Select Bitmap Reset Load Save Delete Hew Entry lear Bitmap Figure 24 Mapping table In the tree view open the context menu of Global Objects and add an alarm generator Label the alarm generator with Freeze Alarm On the context menu of the alarm generator select Add Data Point Since we have no output network variable of type SNVT alarm 2 we will generate a register which stores the value of the alarm generator To create a new register click on the New button and edit the field on the bottom of the dialog window For the Name enter rwFreezeAlarm for Type select Reg Write Change the Name in the Register Properties field to FreezeAlarm and set the Type to alarm 2 164 For Element keep the value Select the new element in the list and click on OK Select Add Data Point again on the context menu of the alarm generator and add the nviTemp data point to the alarm generator In the Alarm Generator tab Figure 25 of the alarm generator set the alarm conditions for the alarm We will trigger an alarm when the temperature falls below 3 C For the Data Point Value Range set the minimum value to 3 For the Alarm Condition select Below Min In the Action field select Set and Clear Alarm For Alarm Set Type select AL ALM CONDITION For Alarm Clear Type select AL NO CONDITION In the Description field enter Freeze Alarm The different alarm type
90. a network output If the register contains the result of a complex calculation or 1s controlled by various objects across the whole project it is easier to have one single point of connection to the outside world instead of connecting the network output in parallel to the register write data point at every location where the register 1s written It may also be used to connect input and output data points which are of similar but incompatible types for example receive a value from a SNVT_ temp variable and output its value via a SNVT temp f variable If a structured data point should be connected entirely to another data point of the same type each of the structure elements needs to be connected individually using a separate connector because each connector is only able to handle single values LOYTEC electronics GmbH L Vis User Manual 86 LOY TEC NOTE The functionality of a data point connector or any other object for which a change of an input value causes updates to an output value without any further conditions or limits is inherently dangerous You must be careful not to cause endless update loops using these types of objects See the section about update loops for a discussion of the problem 8 12 Mathematic Objects Mathematic objects are used to do calculations on connected input data points and assign the result to the connected output data points The object calculates its formula every time an update is received via one of the
91. a number of similar objects is to be created configure the first object press the default button and then create the other objects The set defaults are saved together with the project so that the same defaults apply the next time this project is loaded To change the defaults for an object change the design as needed and press the default button again to update the stored default settings The color property page is used to configure color and transparency for all visible objects To avoid different color property pages for every object the colors are set through this common page using common names for the different colors Not all objects support all colors When an object is selected it will report its color configuration on this page and set all unsupported colors to unset black cross To change a color click on the corresponding color button and select the new color from the dialog Most colors are named such that it is clear to which element of an object the color applies like Text Background Selection and similar Colors which need more explanation are the three line colors How the available line colors are used by a particular object can be found in the objects documentation The right side of the color page allows to set the current color scheme for multiple objects at once Applying a color scheme to multiple object means that all colors which are set in LOYTEC electronics GmbH L Vis User Manual 52 LOY TEC NOTE Ver
92. able menu item If both icon and text are set the icon will appear on the left side the text on the right side If the icon 1s smaller than the reserved bitmap width of the menu the icon will be centered inside the bitmap width On the Color property page the following colors can be set for the menu item Element to which the color applies Frame drawn around the selected item Bar Bitmap Color of a monochrome bitmap Color of the bitmaps background This will be the color which is shown Background transparent in the items bitmap The background of a menu item is always set to transparent mode Table 9 Color assignment for menu items LOYTEC electronics GmbH L Vis User Manual 57 LOY TEC 8 4 Page Page objects are simple objects to organize the control elements which are visible on the device When a page object is connected to a menu item and the item 1s selected from the menu the page and all the controls on it will be shown on the display Previously visible controls will be hidden but will continue to exist on the device so that a trend control may continue to record data for example Technically the function of a page therefore is to group a number of controls together to show or hide them all at the same time 8 4 1 Page Properties Version 3 1 On the Common Properties page a bitmap for the page background may be specified Such a bitmap should match the dimensions of the page which is 320x240 pixels on curre
93. actions between the objects are defined by their location in this object tree for example a menu item object will always display a menu item on the device but it depends on the location of the object in the tree in which menu and at which position in the menu the item appears There are objects to represent menus menu items pages various types of controls to display and input data there are objects to perform mathematical operations on data or generate alarms The total number of different object types is kept to a minimum and the objects are designed as generic as possible to ensure a steep learning curve and allow flexible and creative use of the available objects as the building blocks of more complex applications When building the object tree there are certain limitations in how objects can be connected to each other Most of the time this will be clear from the context for example it is clear that you cannot connect a page object to a menu since a menu would not know what to do with a page A menu is used to manage a list of menu items from which the user may choose Therefore a menu object will only accept menu item objects as child objects A page object can then be attached to a menu item object causing the item to show the attached page when it 1s selected from the menu Such limits are enforced by the configuration software automatically so you cannot drop or paste objects into places where they have no meaning Some obje
94. acts as a dropdown list of commands available for this day The various operations which can be performed on a schedule control are explained in more detail in the following sections Many of the operations may be restricted to a certain access level by the project designer so 1t may be required to enter a PIN code before all of the operations are available For more information on access control setup for schedule controls refer to section 8 5 9 The update mode used by schedule controls is fixed to Focus Loss meaning that the new schedule configuration will be written to the scheduler only at the time the control leaves edit mode This avoids intermediate updates while the user is still modifying the schedule which could result in temporarily inconsistent configurations 6 2 1 1 Select a Schedule If more than one schedule data point is connected to the control a small triangle is drawn to the left of the schedule name and touching the schedule name will open a dropdown list of all available schedules for selection This action is not restricted by access level settings so the dropdown box is always available to select one of the connected schedules 6 2 1 2 Select a Day Touching one of the day names in the left column will show the corresponding time table for that day in the right column If the day is inactive its name will be drawn in the same color as the background of the header lines instead of the normal text color Since this colo
95. alue Preset To select a different value for an entry in the time table touch the value name to open a dropdown box This box contains a list of available values followed by some commands which will be explained later Select the desired value from the list This operation may be restricted by access level in which case the control will not react to a touch of the value name 6 2 1 6 Set Effective Period If shown in the header line the effective period of the schedule may be changed by touching the individual elements of the start and end date and setting new values for day month and year using the keypad To clear the start or end date no restriction select any of the fields day month or year press the Clr button in the keypad to delete the value and press OK to close the keypad This operation may be restricted by access level in which case the control will not react to a touch of the effective period 6 2 1 7 Edit Values of a Preset NOTE To change the physical values assigned to a value preset touch the preset name to open the dropdown box From the box select the command edit to open a small window showing the current values of the preset If the value preset consists of multiple individual values each value is shown on a separate line with the value name to the left and the current value to the right Touch the value to open the keypad and enter a new value When done close the window by touching the close symbol n the
96. ample the sunblind demo uses bitmap controls together with action objects to move a sunblind to special positions or move the sunblind up down or stop the sunblind 15 5 Split Demo The project Solution examples manual lcp contains a Split Demo page Version 3 1 LOYTEC electronics GmbH L Vis User Manual it Solution_examples_manual 1 L Vis Configuration File Edt Model Firmware View Help Oe A Be amp amp RD gt Page Root Menu Example Pages Spit Example Root Menu Menu Navigation B Main mera Example Pages Switch Example sunblind Example Animation Example SD MT Bit O input mapping ae rw Slate LRO FT B 1 input mapping Hi rustate br 1 HF Dit 2 input me rustate bEZ me rwState bk3 49 Output bimap mappINY lt Merged ltsi 9 Back Icon f Show Man Menu Counter Demo Sebup Menu y Global Objects 3 Math obyerts Counter Increment by 10 Decrement by 1U G Merge Firs For Help press Fi LOYTEC Subsystem 1 L VIS ONNET General Common Properties Mapping Data Point Color Menu Page Page Monu View Timenut N sen Containes Width Locked Page Bitmap Width Invisible Page een Scrollbar With 7 Enable Background L LOYTEC www loytec com O Menus 1 Items I Pages 6 Controls 44 Datapoints 41 Size 194 Figure 40 Split example configuration The split demo shows how to merge the input of a SNVT state varia
97. an be used to move controls one pixel at a time and to resize the control when the shift key is held down 2 4 3 Create Data Points In order to have some data points which can be controlled and displayed it is necessary to either create some server objects on the L Vis device or have other BACnet devices accessible in the network To keep the tutorial independent of other devices we use the data point manager window to create a few local server objects This window is accessible either from the tool bar the icon left to the connect button or from the main menu Edit gt Datapoints Please skip forward to section 9 3 29 3 3 for a description of how to create local server objects Following this description create one analog input object and one binary input object You should get one output data point for each of the input server objects Using these data points the value of the server objects can be written To demonstrate how to display the value of remote server objects usually located on other devices in the network we will use our own server objects and pretend they are located on a different device To do so we first need to download the project to the device so that the server objects are actually created on the device Press the button with the red down arrow in the toolbar or select Write Project to the Device from the Connections menu and confirm the dialog After the device rebooted open the data point manager window again
98. an issue when loading old Windows fonts for other than western languages Such fonts may be converted to BDF format in order to allow recoding using the installed encoding tables 13 11 38 PCF File Format NOTE The PCF Font file format is a free open file format designed to store bitmap fonts The specification of the file format can be found at http pfaedit sourceforge net pcf format html Since PCF is a free format there is information available on the internet about font conversion utilities to convert existing fonts from other formats e g True Type fonts to PCF format These fonts can then be used on the L Vis device Tools which are freely available to convert from Windows TTF fonts to PCF format include ot f2bdf to convert the TTF or OTF font to BDF format of a given pixel size and bdftopcf to convert the BDF file into a PCF font 13 12 Using Color Bitmaps Version 3 1 Current L Vis devices use a 256 color display with a standard VGA palette If a true color image is loaded like for example a JPG 32 bit BMP or similar the configuration software will automatically adjust the image to fit the VGA palette using a Floyd Steinberg dithering algorithm This algorithm which is based on error dispersion is applied in conjunction with an alternating raster scan technique to provide the best possible result so it 18 not necessary to run your JPG through the same color reduction algorithm using a separate graphic editor You wil
99. and off LOYTEC electronics GmbH L Vis User Manual 13 1 6 OEM Bitmaps 132 LOYTEC In this section bitmaps can be specified to customize the about page shown during system boot and the PIN code entry page shown when a protected page is accessed and the current access level is not sufficient The bitmaps must match the resolution of the display 320x240 Suitable template bitmaps are installed together with the configuration software 13 1 7 System Colors This section is used to adjust the general system colors They will be used on the device by elements which are created dynamically for example the keypad and will be used by the configuration software as default colors for new objects when no other defaults are set by the user using the button Set as Default on the Common Properties page 13 1 8 System Settings The settings which can be made in this section are 13 1 9 Data Access Device Name A device name can be given using this field It will be used as the host name when the device requests an IP address at a DHCP server and it will be used as a server name by the built in VNC server The device name will also be available on the device in a system register so it can be displayed or connected to other data points so that it can be seen on the network Time Source This dropdown list allows to set a specific source for time synchronization This avoids possible conflicts if there s a time signal coming in from mor
100. are created and deleted together Name and instance number of the created server object for the scheduler may be set in the same way as for any other server object LOYTEC electronics GmbH L Vis User Manual 101 LOY TEC For CEA709 devices resource allocation is more complicated Once the required resources are configured in the Network Settings Dialog the local scheduler data points will be assigned to the available scheduler objects of the device Each new scheduler point will pick the first available scheduler object until all objects are used Scheduler points which cannot be assigned to a free scheduler will remain unassigned until enough schedulers are created or other scheduler points are deleted The assignment is shown in the columns Index and Object in the point list These are the functional block index and name of the assigned scheduler Deleting a scheduler data point will detach the data point from the respective scheduler object and make this object available for other scheduler points which may still be unassigned due to missing resources or which may be created in the future The assignment of other scheduler points to their scheduler objects 1s not changed 9 4 7 Using the Scheduler Once the above setup is done the scheduler is basically operational It will immediately start to work based on the configuration data downloaded through the configuration software However in almost all cases it will be required to add a contro
101. assigned to them Use different bitmaps so that you can distinguish between the individual states The size of the control will always be the width of the widest icon and the height of the tallest icon You can test the look of your bitmap control by selecting the individual states in the mapping table and watch the LCD preview The state which is selected when you write the project to the device will become the default state of the control LOYTEC electronics GmbH L Vis User Manual 24 LOY TEC 2 4 Write the Project to the L Vis device We are now ready to write the project to the L Vis device but first the project should be saved in a file on the PC Although it is possible to read the project back from the device it should not be considered a 100 safe place for the project to be since the device may erase the project in case it finds a severe error which would otherwise prevent it from booting up again If the erase jumper at the back of the device is set or the Remove Configuration command is selected from the File menu the project in the device may be lost as well so it is a good idea to have a backup copy ready on the PC To save the project select Save as from the File menu and enter a project name To write the project to the L Vis device press the button with the red down arrow in the toolbar or select Write Project to the Device from the Connections menu and confirm the dialog Once the project file is written to the
102. ata point as a Boolean value setting it to either O OFF or 1 ON Using the data points scaling factors this input may be translated into any two values one to signal alarm clear and one for alarm set This is most useful if the generated alarm 1s to be processed further or displayed on the L Vis device for example to trigger actions or display warning messages e Multi State Value Similar to a scalar value but the alarm generator can be configured to set the output to any of the available states which can be selected LOYTEC electronics GmbH L Vis User Manual 83 LOYTEC easily from a dropdown box Useful on BACnet devices where a multi state point may be used to signal a number of different alarm conditions SNVT_ switch Available on CEA709 devices a data point representing an entire switch variable may be connected In this case the alarm generator sets both value and state of the connected switch to either ON 100 or OFF 0 Useful in cases where the generated alarm is to be processed by a remote device which uses one switch input for each alarm SNVT alarm2 Available on CEA709 models a data point representing a SNVT alarm2 structured NV may be connected In this case the user may set all elements of the alarm2 structure to the desired values including the alarm priority and a description This is most useful to communicate the result to a remote device which provides a compatible alarm input variable 8 10 1
103. ation software in plug in mode as detailed below If there are any changes required for the dynamic NVs on the device perform them as the first step using your network management tool Run the configuration software in plug in mode on the device which is to be changed This will automatically update the dynamic data points according to the changes which were made to the dynamic NVs on the device Load the current project from a file or from the device and modify it as required adding or removing static NV data points During the load the data points used in the project are updated according to the new set of dynamic NV points If dynamic NVs were removed or renamed the affected data points need to be manually assigned to other NVs or may be deleted from the project Download the new project to the device A warning appears stating that this will change the static interface of the device and that the database needs to be updated to reflect these changes The configuration software will execute all required steps automatically temporarily removing all dynamic NVs and all bindings to guarantee a correct update of the device Once the device restarted and the database was updated the NVs and the bindings are restored The device is then commissioned and ready to operate WARNING It is dangerous to change the static interface while using dynamic NVs due to the fact that all dynamic NVs must be removed in order to upgrade the static inter
104. background image will require an additional 78kB of memory To place small logos or page headers use a bitmap control instead and select a suitable background color for the rest of the page This will save a large amount of memory As you lay out the controls it is a good idea to also set their properties to modify their appearance since this will ultimately change the size of the controls and may have an impact on their placement on the page For text and bitmap controls you should already have the data points connected and the mapping tables filled in bar and trend controls should have their final settings of scale tick marks and value range The individual property pages are discussed in more detail below Add actions alarm generators mathematical objects and other global objects you require to put functionality into your project Fine tune colors and transparency on the Color page and layering by using drag and drop in the tree view This is of course not a complete list of things to do but should give you an idea where to start from a blank project If objects or complete pages are copied from one project to another project the copied objects may contain references to data points or loaded fonts which do not yet exist in the target project If possible any missing data points or fonts will be created automatically in the destination project If this is not possible for example if an object references a data point from a foreign
105. ber of possible options e Switching to a page which cannot be viewed at the current access level will automatically bring up a system page where a PIN code can be entered in order to increase the access level and access the page e On anormal project page a numeric input control can be placed to allow the user to write a PIN code value to the system register called PIN Code Enter Any value written to this register will be interpreted as a PIN code and the system will try to log the user in using this code If none of the defined access levels has a matching PIN code the access level is set to 0 log out To construct a suitable LOYTEC electronics GmbH L Vis User Manual 134 LOY TEC control make sure to set the input value range to 0000 9999 and check the Password Input Keypad option e Using a data point connector a PIN code can be received from the network and forwarded to the PIN Code Enter register to allow remote login using a PIN code e The desired access level may be set directly by writing a value between 0 and 15 to the system register called Access Level This is less useful f allowed from a control on a project page but may be convenient if there 1s an external access controller in the network where the user was already authenticated for example using an RFID card The access controller can communicate the successful authentication over the network to the L Vis device where a suitable access level can be set directly
106. bes how to operate the touch display of the L Vis device Most operations should be fairly intuitive so that users of the device do not need to read a manual before they are able to operate the device L Vis devices use a resistive touch screen This type of screen can only detect one touch position at a time that is you cannot press two buttons at once The screen delivers raw data which must be converted to LCD pixel positions before t can be used therefore a touch screen of this type needs calibration All devices come pre calibrated from the factory and should be accurate enough to operate the device out of the box To operate a device using very small control elements or from an unusual viewing angle it may be necessary for the user to re calibrate the screen using the built in calibration function which is available in the setup menu section commands The procedure is explained in more detail in the next section The touch pressure 1s currently not measured and has no effect on the operation The touch display is able to detect three different input actions e Touch one point at a time e Touch and hold e Touch and move The simple and intuitive touch operation is used to select menus select controls and enter data on the input keypad This is straight forward The touch and hold operation opens the navigation menu after a configurable time 0 to 5 seconds Please note that for correct operation the touch and hold action shou
107. bjects may be created where each alarm server object will be connected to a separate notification class object on the device e Remote Devices This folder is used to collect all remote calendars schedulers and alarm client objects which were created from network scan data For each remote device a subfolder will be created where the objects referencing this device are collected Note that references to normal external data points go into the External NV or Client Mappings folder Using the context menu on a folder sub folders may be created to organize the available objects If new objects are created automatically they are usually placed in the base folder and can then be moved by the user to any of his sub folders 9 2 2 Data Object List Version 3 1 At the top right a list of all data objects which are available in the selected folder is shown From this list objects may be selected including multi select in order to modify some of their properties A double click will select the data object and then close the window same as the OK button which is useful when adding new data point objects to the object tree in the main window The columns of the list will vary depending on the type of objects shown Always visible are the data object name and the unique ID by which this object may be referenced Also shown is the number of times this object is currently referenced from the main object tree the L Vis project Only data objects w
108. ble into a single bitmap control In some projects it is required to evaluate the input of a SNVT state variable where only one bit is set and display the result in a single bitmap or text control The example uses the single bits of the SNVT_ state variable to feed a mathematic object The mathematic object encodes the bit to a single numeric value and passes the result to a register The register feeds the mapping table of a bitmap control which displays different bitmaps according to the register contents 15 6 Counter Demo The project Solution examples manual lcp contains a Counter Demo page Version 3 1 LOYTEC electronics GmbH L Vis User Manual 158 LOYTEC uk Solution_examples_manual 1 L Vis Configuration Fie Edit Model Firmware Wiew Help Dah tae 313 gt Subsystem 1 L415 ONNET Page Root Menu f Example Pages f Counter Demo Root Menu ME Menu Navigation General Common Properties Mapping Data Point Cokr Menu 7 Page D Man Menu Example Pages Pags Menu wikch Example Views Timeout O sen Container Width sunblind Example e 6 A l Locked Page Ditmap width Invisible Page Spit Example FT Defaut Page Jaiba Wiin Counter Dena Enable Background 4h0 Counkerz Humber er ReclounterWalue l Counter Mumber 47 Courter 1 Label D LOYTEC mappuang E wunaloytac com RecCounterWalus 4 Container 1 4E counter 1 value er rRecCounterValue IT Counter 2 Label 4 Container 2 AE coun
109. by pressing the status button located at the bottom of the device or by selecting the Send Service Pin Message command in the Setup gt Commands menu of the L Vis device see Setup Menu Set the device configured online during the commission phase so that the device will be able to communicate with other nodes on the network and with the configuration software NOTE Do not integrate the device into your project by uploading the device interface properties from the device before you registered the plug in This is important because if you upload the definitions from the device you will create a template of your own and the configuration software will then fail to create the real device template once you register it In this case you must remove the device and the template from the database and re run the plug in registration 2 3 1 2 CEA709 without LNS Assign a network address Use your network management tool to add the device to the database and assign a network address to it Alternatively go to the CEA709 page of the setup menu and enter a suitable network address manually then press the button SET ONLINE to activate the address 2 3 2 Create Dynamic NVs LNS only In this example we will create two dynamic network variables of type SNVT_ switch on the device one input and one output and bind them together turnaround binding to show how to display and send out data NOTE If your network management tool does not support
110. cccessssccccssssscosees 107 10 1 Deyice Integration taa 107 UNETE NeW Device iciot 107 L0 1 2 Pre Pro91ammed DEE aa 109 10 2 Device Replacomen tancias alii cota iria caian 110 10 23 name NV Projects ee 110 10 2 2 Stall NV Projects este eis 110 10 2 3 Mixed Projects static and dynamic oococcccnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnininininos 111 10 3 Configuration Chance iia ii ah iii 112 10 31 Same NV Comm curaio ne 112 10 32 Dynamic COMA dada 112 FO Statice NV CNAN oo 113 10 4 Configuration REcovery asseris a 114 1041 Change Device Configuration lid ad 114 10 4 2 Change Network Configuration cccccccccccccnnnnnnnnnnnnnnnnnnnnnnnnnnninininininnnnns 115 10 4 3 Recover froma failed Updates anne 115 Ti Special Functions CEA 709 aussehen 118 11 1 Bindine Management 118 11 2 AIR NOV ee a Es 118 PAR wen 119 LN Seren ltda 119 11 3 CCEATOO 1 A Operation ic ds 119 11 4 Dynamic Network Variables aaa aaa ad 119 11 4 1 LonMaker Network Management Too 119 A ee nes eier 122 LOYTEC electronics GmbH L Vis User Manual Version 3 1 7 LOYTEC LEE RAR see Rees 124 11 5 Built in LONMARK Objects esssssessnssenenenennonnnnnnnnnsnenenenenensnnnnennnnnnnsnenenen 127 El Dim OD ee eng 127 EAS Object ee else 127 11 53 Relay LCD Backlight control aaa a ies 128 11 5 4 HVAC Temperature Sensor nein 128 12 Special Functions BACNED iii id iii aniaosd 129 12 1 EDE Export o
111. ch controls and set a high number of history pages In the same section you may set a minimum Shift Interval for the control The control normally uses the smallest usable shift interval which is the time it takes for the graph to move by one pixel The graph cannot be shifted earlier than this because it needs to move by at least one pixel can t move by half a pixel If this interval seems unnecessarily small each shift will require some processing time or you want the control to average data over a longer time frame than this you may set a minimum time here The control will then use the next higher shift interval which results in an integral shift of the graph in pixels The Flags to enable or disable the tick marks and the scale are the same as for the value axis Below the time axis section a small information area shows the resulting update rate shift rate of the graph the amount of pixels the graph will be shifted each time and the amount of memory required for the requested history pages On the bottom left there are some additional Flags to be set Depending on the selected object there are different flags available With the trend control selected the following options can be set e Enable Cursor This option causes the control to become selectable When selected a cursor appears which allows navigating through the recorded data see the next section e Draw Grid This option enables a grid which is automatical
112. ch fires only when the screen is again released inside the control A touch is also triggered when the control was released by moving outside without releasing the screen and then returning back inside the control e release The action is triggered when the touch screen is released while inside the control or when the touch position moves outside the control while the screen is still being touched The trigger of touch and release actions while moving the touch position around between controls without releasing the touch screen is consistent with the display of the selection frame Moving from one control to another without releasing the touch screen will cause the selection frame to follow the movement always marking the control which is currently touched The touch and release actions will follow the same pattern triggering the touch action when the selection frame appears and triggering the release action when the selection frame disappears While the action type is independent of the parent object to which the action 1s connected the available action triggers vary depending on the capabilities of the parent object since the action object needs information from its parent to check for trigger and execute conditions The following limits apply e Control If the action is connected to a control all available triggers and conditions may be used since a control delivers both a value and user input events touch release select and simila
113. commissioned hold the service pin button pressed while the unit boots and release the button within 10s when instructed to do so by a message on the display Behind the small hole next to the status button 1s the reset button Use a pin to reach the reset button in order to hard reset the device Doing this may cause trend log data or other persistent data to be lost or reverted back to earlier data To avoid data loss reset the device via the configuration software or the setup menu command page Power LED The power LED lights up green as soon as power 1s connected Status LED ACT 709 LED ACT BAC LED The status LED lights up red when the internal persistent storage device is accessed Also on CEA709 models operated on an FT 10 LPT 10 channel this LED indicates the node status The LED is off if the node is configured online and flashing red with a period of 1 Hz if the node is in the un configured state This LED indicates incoming and outgoing data packets on the currently active communications channel Only packets which are addressed to the device are shown LINK Ethernet LED The LINK ETH LED indicates a successful Ethernet link ACT Ethernet LED The ACT ETH LED shows activity on the Ethernet network ONLINE LED CNIP LED LVIS 3E100 Version 3 1 The ONLINE LED lights up green if the node is in the configured online state CEA709 models only This LED either shows the current status of the IP 852
114. connected input data points so that the output value is always accurate If a complex formula is used which operates on a large number of input data points the resulting update rate of each input data point should be considered so that the resulting total update rate remains reasonable 8 12 1 Math Object Properties NOTE NOTE Version 3 1 Mathematical objects are configured on the Math Object property page where basically the formula is entered Before doing so it is important to connect the required input data points to the object so that they are available as variables for use in the formula All connected input data points are listed on the left side of the property page and variable names are assigned to the data points in the order in which they are connected to the math object Variable names start with v1 and continue with increasing numbers like v2 v3 v4 and so on There is a limit of 127 input data points per math object Formulas using more than 127 input variables must be split into individual sub expressions which should be done anyways since a formula with such a large number of variables becomes unreadable Always keep in mind that the order in which the input data points are connected to the math object in the tree view defines the assignment of variable names for the formula If you replace input data points when the formula was already specified be careful not to mess up the data point order and thus the result o
115. cs GmbH L Vis User Manual 45 LOY TEC NOTE The Import from XML command is similar in function to a paste command The difference is that it reads the object to paste from a given XML file instead of the windows clipboard The XML export and import functions are intended to be used for custom tools which may be able to build a complete project in XML format out of basic building blocks which were prepared and exported to XML fragments Based on information in a network database a custom tool may read the individual XML building blocks which for example describe individual pages of the project and put them together into a complete project which may be loaded into the configuration software and downloaded to the device 7 2 5 Manage Data Points This command is available in the context menu of menus items pages and folders It will open a new dialog listing all data point objects below the selected object which data object they reference and which type and direction they have This dialog is useful to organize data references do batch renaming of data sources or reassignment of data points to different data sources as is often required after copying parts of a project for example to add a page for a new room based on the page of an existing room but referencing the data objects of the new room Depending on the selected objects in the data point list multi select is possible some of the operations available using the buttons at th
116. ct can be configured in the same way as any other server object On CEA709 devices the device firmware must provide a software module to handle alarming To activate this module open the Network Settings Dialog which is accessible from the File menu and check the option Enable Alarm Server This will add new NVs and thus change the static interface of the device 9 5 4 Using Alarm Servers Each alarm server keeps a list of currently pending alarms distributes them to any clients which may be connected to the server and also receives acknowledge requests from either the application or connected alarm clients To access the current list of pending alarms on an L Vis device there is a specialized control available to which alarm server and also alarm client data points may be connected Please refer to section 8 5 9 2 for more detail about alarm list controls 9 6 Remote Scheduler and Calendar Version 3 1 Adding remote access to the configuration of a scheduler and calendar which is located on another device is done by creating remote scheduler and calendar points These points may either be created from data obtained by a network scan or can be created manually CEA709 only Here are the steps to create the required points from a network scan e Execute a network scan as described earlier in this document e From the points in the import folder select the scheduler points you are interested in and use the command Use on Device to crea
117. ct the desired interface set the jumper at the back of the device as explained in section 5 1 Reboot the device for the changes to take effect 2 4 2 Start the L Vis Configuration Software Version 3 1 Run the installed L Vis configuration software from the start menu of your desktop Connect to the device by pressing the Connect button from the tool bar or select the menu item Connect to the Device from the Connection menu of the main window The configuration software contacts the device finds out what model and firmware version it is selects the correct settings and disables the corresponding menus so that you may not change them The main window will show an empty L Vis project The main window is divided in tree major sections Tree View On the left side of the main window is a tree view showing all objects you created so far and how they relate to each other for example a menu object may have menu item objects attached to 1t a menu item object may have page objects and sub menu objects attached and a page object contains the elements to display and enter data these elements LOYTEC electronics GmbH L Vis User Manual 21 LOY TEC NOTE are called controls in this manual You may navigate through this tree and select an object from it or drag and drop objects to move them around in the hierarchy for example grab a control from one page and drop it on another page An empty project contains only a root menu and a folder
118. cts a collection keeps record of the position and size of the bounding box which can be drawn around all visible objects contained in the collection This data can be seen on the Common Properties page 8 9 2 Collection Handling NOTE Version 3 1 If a collection is part of a project page and contains visible objects a bounding box around all objects contained in the collection is drawn in the preview when the collection is selected Using this box the entire collection may be moved to another location on the page It is also possible to resize the bounding box which will evenly spread out the contained objects For example if a collection contains three objects in a horizontal row where the second object is located in the center resizing the bounding box will keep the leftmost object at the left edge the rightmost object at the right edge and the middle object in the center of the bounding box that is the relative position of each object in the collection does not change A collection can only be resized when there are at least two visible items inside the collection In addition resizing is only possible in a direction where at least two controls are not at the same position This is a direct consequence of the way resizing works To select a control inside a collection the easiest way is to select 1t from the tree view at the left If the control is to be selected directly in the preview there are at least two objects on LOYTEC
119. cts may be connected to a number of other objects for example a data point may be connected to all kinds of controls but a trend control only accepts input data points not output data points Mapping table objects may be connected to text bitmap number and bar controls but not trend or date controls and so on Using the context menu of an existing object to create a new object automatically will show only the kind of objects which can be attached to the existing object so there is no room for error A typical object hierarchy which shows the most important relationships between the available objects is shown in Figure 5 The individual objects are explained in more detail in the following sections LOYTEC electronics GmbH L Vis User Manual 54 LOYTEC Figure 5 L Vis Object Hierarchy Version 3 1 LOYTEC electronics GmbH L Vis User Manual 55 LOY TEC 8 2 Menu NOTE A menu object is used to manage a collection of menu item objects On the device a menu is a window which opens on the left side of the display and shows the items which are contained in the menu The menu can handle more items than fit on the screen If this is the case a scroll bar is provided for the user to move the contents of the menu up and down to see the hidden items Every project always has a menu object as the top level object This is called the root menu It must always be there and it cannot be deleted However you may adjust its properties Just
120. current status of the switch input using a text control for the state and a numeric control for the value To LOYTEC electronics GmbH L Vis User Manual 18 LOY TEC NOTE control the switch output we use a bitmap control for the state and a bar control for the value To create the required controls either right click on the page object in the tree view and choose the control type you want from the context menu or select the page in the tree view and right click in the LCD preview area to reach the same context menu Add one text control one bitmap control one numeric and one bar control to your page Now place the controls on your page so that they do not overlap each other Grab and drag them with the mouse or enter position and size in the Screen Coordinates section of the Common Properties page To resize the controls with the mouse move the pointer to the lower right corner of the controls area in which the value is displayed that is disregard any decorations around the value area like the scale of a bar control For most control types the value area fills the entire space of the control except for the selection frame For more complex controls like bars and trend logs you can view the value area by changing the Container color on the Color property page Then grab the control at the lower right corner of the container area The position and size you set on the Common Properties page also refers to the value area of the contro
121. d be 10 0 20 2 The scale labels and tick marks if enabled are automatically calculated and laid out If the page background already provides a graphic representation of the scale and the control 1s only used to fill in the data the scale and tick marks may be disabled The best way to lay out the control is to first enable all required decorations scale ticks and grid and then change the size and position of the control to fit the scale Regarding color the trend control is one of the most complex controls to configure since it supports a large number of colors The following colors may be set for trend controls on the Color property page Element to which the color applies Background of the graph area which is the rectangular area spawned by Container q the value and time axis Color of the background outside the graph If the transparent check box Background 1s set all pixels using this color will be transparent Table 13 Color assignment for trend controls To set the color of the individual curves select a data point and switch to the Color property page You can now set the color of all curves which may be generated by this data point Element to which the color applies Color for the minimum curve 1f enabled Color for the average curve if enabled Color for the maximum curve 1f enabled Color to indicate that the current value of a curve is out of range If the Line4 value axis is adjusted to fit
122. d to select one or more data objects when a data point is to be added to the object tree It is therefore possible to create and select a data object in one go The window is divided into different sections 9 2 1 Folder List Version 3 1 At the left is a list of folders which is used to sort the available data objects by their category There are a number of predefined folders available e Imported This folder has two sub folders One is used to hold data retrieved from a network scan the other one is used to display data imported from files Data objects in the import folder are not stored on the L Vis device when the project is downloaded They represent data objects which are available on remote devices and are shown here as templates to create suitable data objects for use on the L Vis device see the section Remote Network Object for details e Local NVs Server Objects Objects which represent a local network variable or local server object are located in this folder Select the folder and use the New button or the context menu to create a new local data object e External NVs Client Mappings Objects which reference remote network variables or server objects on other devices without connection to a local network object are located in this folder These are usually data objects which LOYTEC electronics GmbH L Vis User Manual 92 LOYTEC were created from points in the import folder by using the option Use on Device fr
123. dates This option causes the data point to filter out updates which set the value invalid for example because the value cannot be determined from the network Normally the invalid state is passed on to the other side If this option is checked the update is not forwarded so that there is no change to the current value e Map Invalid to Default This option causes the data point to map invalid updates to the default value specified in the Default field This is useful for input data points which may be unavailable for example not bound and this situation is not considered an error Using this option unavailable data can be replaced by a safe default If the invalid state would be forwarded and the value would be used in a calculation the entire result of the calculation would become invalid which may not be desired In the Data Point Value area the default value for the data point can be set This will be the value of the data point until a new value is received from either the network or the user or a value which was saved to non volatile memory is loaded after system start If this field is left blank the initial value of the data point will be invalid this state is also visible on the controls LOYTEC electronics GmbH L Vis User Manual 75 LOY TEC NOTE NOTE NOTE Version 3 1 The default value of a data point ultimately refers to the value of the underlying data object Since the referenced data object can only have on
124. dback over nviSwitchFb The object is configured using the configuration properties e SCPTmaxOut e SCPTmaxSendTime e SCPTminSendTime e SCPTstepValue e SCPTtimeout The configuration properties are described in detail in the LONMARK Function Profile documentation On L Vis the switch object is controlled by a switch or push button connected to the Switch terminal INO of the device The object can operate in 3 different modes 1 Switch mode Use this mode when a two position switch is connected to the input terminals To select switch mode set SCPTstepValue and SCPTtimeout to zero 2 Push button mode Use this mode when a push button is connected to the terminals and you want to toggle the light on and off with LOYTEC electronics GmbH L Vis User Manual 128 LOY TEC each push of the button To select push button mode set SCPTstepValue to zero and SCPTtimeout to a value greater than zero 3 Dimmer mode Use this mode when a push button is connected to the input terminals and you want to use the button to toggle the light on and off with each short press of the button and ramp the light intensity up and down when holding down the button To select and configure dimmer mode set SCPTstepValue to the amount of change wanted for each step when ramping up or down and set SCPTtimeout to the desired maximum push time which is detected as a short press the time to wait before starting to ramp the light intensity up or down T
125. dd and Remove Entries NOTE To add a new entry to a time table select the insert command on the last line after the last entry n the list A new entry will appear with the default time 23 00 and the first available value preset Now edit the new entry as described earlier change the time and the value preset This operation may be restricted by access level in which case the control does not react to a touch of the insert line The scheduler unit may report a restricted capacity for entries in the time table If this limit is reached the control will not allow any further insert operations To remove an entry from the time table touch the value preset name of the entry which s to be removed and select the remove command from the dropdown box If this operation is restricted the remove command will not be selectable 6 2 1 10 Activate Deactivate Days To activate or deactivate individual days select the desired day from the left column and touch the headline of the time table to open a dropdown menu From this menu select activate or deactivate only one of the two commands will be shown If this operation is restricted the time table menu will not open 6 2 1 11 Clear or Copy Time Tables To clear all entries in a time table or copy them to a different day select the day to clear or to copy from in the left column and touch the headline of the time table to open a dropdown menu From this menu use the clear or the various c
126. ded to the bitmap control in a later step 2 4 6 Connect the Data Points NOTE NOTE Version 3 1 At this point connect data points to the controls Especially for text and bitmap controls it helps to connect the data points early since the configuration of the controls property will depend on the data point connected you will see why this is the case in a minute To add a data point to a control select Add Data Point from the controls context menu The dialog which was used before to create the required data points will appear for selection of the desired data points This dialog is explained in detail in section 9 for now we just use it to select the data points which should be connected to the control A data point is selected by a double click or by selecting one or more points multi select 1s possible using the shift key and using the OK button Use the above procedure to add the binary client mapping to the text control the analog client mapping to the numeric control the binary server object to the bitmap control and the binary client mapping to the bar control When you add the binary point to the text control another object called a mapping table will be created automatically and will be initialized to map the two known states of the binary data point to the state texts listed in the objects properties You may select this mapping table and change the texts as well as assign different colors to the individual texts i
127. device the L Vis reboots and shows the tutorial project on the display 2 4 8 Test the Project NOTE Version 3 1 You should now be able to use the device to set the state and the value of the two server objects and immediately see the results on the client mapping input points since they refer to the local server objects To change the binary server object state press the bitmap control A dropdown list with the two icons you assigned to the ON and OFF states in the mapping table will appear Now select the desired icon to set the state Whenever an element is selected from a dropdown list of icons or texts the device will search the mapping table to find the value associated with the selected element This value will then be assigned to the output data points which are connected to the control The new state will be written to the server object and will be received immediately by the client mapping input The new state should now also be displayed on the text control using the texts which you specified in the mapping table To change the value of the analog server object select the bar control and move the bar up and down The current value will be written to the object received back in through the client mapping and should be visible immediately on the numeric control LOYTEC electronics GmbH L Vis User Manual 25 LOY TEC 3 Mechanical Installation 3 1 Dimensions and Mounting me L Vis enclosure co s of 2 parts The f
128. device should be configurable in plug in mode in the future re run the plug in registration for the L Vis configuration software The new device will be identified as an L Vis device and the configuration software will register itself as a configuration plug in automatically 10 1 1 3 Static and Dynamic NVs NOTE This is the most complicated setup which is not available under all circumstances Projects using static and dynamic NVs at the same time can only be integrated and maintained when the configuration software is run in plug in mode Due to limitations of the network database system the presence of dynamic NVs on the device will prevent a manual device integration if there are static NVs to be created even if you don t actively use the dynamic NV points If possible try to decide on one method and use either only dynamic or only static NVs since this greatly simplifies the integration and upgrade process If necessary a mixed operation is possible but due to the required operations on the underlying database is only suggested for advanced users If used you are advised to have a recent backup of your database ready The integration procedure for such a project is a combination of the procedures used for a static NV project and a dynamic NV project in plug in mode The dynamic NVs must be created on the device in a first step the data points in a loaded project are synchronized with the available dynamic NVs on the device and th
129. ditions is met as opposed to all conditions e If required select a single data point to be used as a master enable disable switch below the trigger list If a data point is selected for enable disable its value must be non zero to allow mail sending If no data point is selected the mail template is considered enabled 9 8 3 Attachments NOTE This tab is used to select files which should be attached to the mail This is used for example to send the current system log file or data log files together with the mail The available files depend on the project and can be selected from the dropdown list Use the Add and Remove buttons to manage the list of attached files Data from trend log or data log controls can only be attached to a mail if the control has the option Preserve Data enabled Otherwise the data is not saved in a file and is therefore not accessible to the E Mail system to include as a file attachment NOTE Attaching a number of large files will require a significant amount of free memory while the mail is being composed and sent If the project itself consumes most of the available RAM this should be taken into account If necessary split the information into multiple smaller mails and send them at different times to reduce the memory requirements Version 3 1 LOYTEC electronics GmbH L Vis User Manual 107 LOY TEC 10 Standard Procedures CEA709 10 1 Device Integration How a new device is integrat
130. drop it on the action object in the tree view The path to the page will be shown in the option area below LOYTEC electronics GmbH L Vis User Manual 78 LOY TEC NOTE Version 3 1 e Next page Show the next page of a multi page menu item This is equivalent to the next page touch gesture and is useful to build a next button e Prev page Same as above but show the previous page e Sound buzzer Output a tone on the internal buzzer The frequency and duration of the tone can be adjusted in the Options section Useful to create audible alarms when a data point or register reaches a certain value e Turn on backlight Turn on the LCD backlight just as if the user touched the display Useful to turn on the backlight based on information from a presence sensor e Update data points Assign a value to all connected output data points The value to send out can be preset by connecting input data points to the action object Useful to update the value of data points under certain conditions Often used to save the current value of an input data point to an internal register when a button is pressed or similar applications When the connected output data point is a constant value point the action may be used to write a fixed value to a register or network object when the action triggers e Service Pin Message Execute the system command send service pin message which is supported by CEA709 models e Lock Pages Log
131. e LEF Vinny Mera id Dia Port Cake Tast Bin Figure 26 Freeze alarm with text and bitmap controls 14 4 Example 4 Using text mapping and Date Control Version 3 1 This example describes how to integrate a date control into a project The date control will display an analog clock It will get the time value from the internal real time clock In addition three text fields will be created which display the actual time in a textual format The time value for this text will be received from a turnaround binding of the real time keeper object Create a new menu item and assigned a page to this menu item On the page add a text control for the header text name it e g Header and enter a text in the Text field of the Common Properties tab e g Text Watch In the context menu of the new page select Add Date In the context menu of the date control select Add Data Point In the dialog window select the System Time parameter and click on OK On the Date Time Control tab select Graphic for the Style and choose a Graphic Style For the text display we need a turnaround bound dynamic network variable which allows to access hours minutes and seconds separately Create a dynamic network variable of LOYTEC electronics GmbH L Vis User Manual 148 LOYTEC Version 3 1 type SNVT time stamp and bind the nvoDateTime variable of the L Vis device to this input variable see Figure 27 L Vis Timer L Vis Exa
132. e bottom of the window may be disabled 7 2 5 1 Naming Rules Version 3 1 Many of the batch operations open a dialog to set the naming rules for the batch operation The dialog provides three different levels of naming rule specification from very simple to very complex and powerful The three options are e No Custom Naming Rule This is the most basic setting It does not apply any special rules on the source name or the target name All selected sources will be processed and the target name will be chosen to be as close to the source name as possible For example the duplicate operation when run with this naming rule will create a data source Testl from the original source Test e Search and Replace This setting is used to specify a simple search and replace algorithm All data sources which contain the search string given in the first input field will be processed The last occurrence of the search string in the original name will be replaced by the replacement string given in the second input field to form the new name Most often used in conjunction with the reassign operation for example to automatically reassign all data points referencing xxx Room001 with xxx Room002 replace 001 with 002 e Regular Expression This is the most powerful setting The regular expression given in the first input field s matched against the original name If the expression matches the entry is processed otherwise ignored If processed the ma
133. e control shows a graph with the value on the vertical axis and time on the horizontal axis The time axis shows the amount of time which has passed since now where the rightmost end of the axis represents the present time with older data to the left for example 10 minutes ago 20 minutes ago and so on As time passes the recorded data moves to the left and new data is added to the right The smaller the time span on the time axis the faster the curve moves to the left When setting the time span the resulting interval between two shift operations is calculated and shown on the property page The control is able to display three curves per connected data point the minimum value maximum value and average value To do this the control records all incoming value updates between two shift operations From this data it calculates the minimum value the LOYTEC electronics GmbH L Vis User Manual 63 LOY TEC NOTE Version 3 1 maximum value and a time weighted average value and adds this data to the right end of each curve The average value calculated during each shift interval is the time weighted average of all input values received during that time frame For example if the input has a value of O for the duration of 9 seconds and a value of 20 for the duration of 1 second the time weighted average value for these 10 seconds will be 2 because 0 9s 20 1s 10s 2 In contrast the time independent arithmetic average value woul
134. e database e The original project must now be loaded a second time but this time the dynamic NV data points can be assigned to the existing NVs and the project should load without errors 10 3 Configuration Change NOTE This section describes the necessary procedures to change the configuration of an already integrated device It depends on the existing project and the kind of changes done to the project how the update may be performed For all configuration changes it is strongly recommended to first execute the download procedure and then store the new project on the PC usually overwriting the last stored project since this guarantees that the model number stored in the file on the PC matches the model number which was automatically selected during the upgrade procedure and that in cases where the upgrade must be aborted the device may easily be restored to the last working project since it is still intact on the PC and not already overwritten by the new project 10 3 1 Same NV Configuration This is the easiest of all configuration changes As long as there are no changes to either the static or dynamic NVs of the device there are no special requirements and no special procedures to follow The new project may be downloaded to the device through any of the available methods where a TCP IP connection is usually preferred The device will restart after the download and will be ready to operate without any further Steps 10 3
135. e device is compatible to the older CEA709 1 A network management commands compared to the extended network management defined in the CEA709 1 B standard To integrate a device using static NVs the configuration software may be run either as a plug in or standalone The procedure when run as a plug in is fairly automatic Create a new device in your database using the provided device template for the L Vis device you are using FT 10 or IP 10L Commission the device so that the configuration software can communicate with it Run the configuration software as a plug in on the newly created device and load the prepared project or design a new project Download the project to the device A warning will appear notifying the user of the required database update The update and the selection of a new model number are done automatically After the device restarted and the database was updated the device is re commissioned and ready to use Keep in mind that during the download a new model number was selected and the project should be saved after the download so that the model number in the file on the PC matches the one in the device If the network management does not support plug ins or the project is downloaded via TCP IP to reduce the download time the device is usually first programmed standalone and then integrated using an XIF file Version 3 1 Connect to the device using TCP IP or CEA709 The configuration software will dete
136. e information in the navigation bar and text color for the label of the ACK button Frame drawn around the entire control if the control is selected Bar Bitmap Background color of the acknowledge button Color of the control background If the transparent check box is set all pixels Background using this color will be transparent Table 18 Color assignment for alarm list controls LOYTEC electronics GmbH L Vis User Manual 72 LOYTEC 8 6 Data Point NOTE Version 3 1 Data point objects control the data transfer between a register or a network value and the controls or other data processing objects on the device To archive this data transfer there are tree objects involved e The control element which acts as the interface to the user or any other object which processes data like mathematical objects alarm generators or action objects e A data object as the source or sink of data for example an internal user register a system parameter a network variable or a BACnet server object or client mapping e A data point object which references a specific data object and thereby links a control to a data source or sink It also defines the properties of this data link for example when new data is to be transferred between the data object and the control and how the data should be converted when it is transferred The control is created as part of the object tree as outlined in the tutorial It exists independently
137. e is defined by the loaded project and is displayed at the bottom of the page If an external time source 1s used only the time zone needs to be adjusted here e Commands This page contains a dropdown list of the commands which can be executed Some commands are available on all devices while others are specific to a device family The following commands are defined LOYTEC electronics GmbH L Vis User Manual 41 LOYTEC NOTE Version 3 1 Send Service Pin Message CEA709 models only Send out a service pin message Unceonheurs Node CEA709 models only Set the device back to un configured state forget network address Clear System Log Clear the system log of all entries ae Dump the current IP statistics to the system log useful Pn Pee to debug IP connectivity problems Save the data of all persistent trend logs right now Save All Trend Data automatically done when a clean shutdown of the device is executed Consider all protected pages to be locked again after the PIN code was entered and the pages were unlocked before This basically sets the current access level back to zero Calibrate Touch Screen Start the touch calibration routine Lock Pages Logout Send Test E Mail Sends a short mail message to the recipient specified as the test receiver in the project settings Ges DitssndRese Clear all persistent data user data points forget their stored value Res Device Perform a clean shutdown and reboot All
138. e processed by the math object which internally uses an RPN machine with precompiled instructions for optimal performance Example add avg vl v2 v3 5 or the equivalent avg vl v2 v3 5 will work add 5 avg vl v2 v3 or the equivalent 5 avg vl v2 v3 will NOT work To limit the number of re calculations the data point update option Value changes only should normally be checked on all connected input data points This avoids recalculating the formula and writing a value to the output data point when it is already clear that the result will be the same because the input value did not change The same option can also be checked for the output data point to avoid unnecessary writes to the output data point in case the inputs changed but the result of the formula is still the same Especially for projects which use a lot of cascaded formulas where the result of one formula is used as input to a number of other formulas it may cause a big difference in CPU usage whether results of the same value are forwarded to other math objects in the system or not because they will trigger recalculation of a potentially large number of other formulas which will generate even more results of the same value since the originating value did not change 8 12 3 Function List Version 3 1 The following function calls are currently supported LOYTEC electronics GmbH L Vis User Manual 88 Function add v1 v2 sub v1 v2 mul v1 v2 div
139. e static NVs defined in the project will be available on the device after a database update The difference is that during the upgrade of the static interface all dynamic NVs will be temporarily removed from the device and the database so that the upgrade can be executed The removed NVs will later be recreated automatically but they may get a different NV index assigned so it is necessary to update the drawing of your device Existing bindings will be saved and restored as well If something goes wrong restore the database from the backup or read the section about device recovery 10 1 2 Pre Programmed Device Version 3 1 In some cases it may be necessary to integrate an already programmed device into a network This can only be done with static NV projects since dynamic NVs are stored in the network database and not the L Vis project and are therefore not transportable from one network to another The procedure is basically the same as integrating a new device with static NVs using the configuration software in standalone mode The only difference is that the first few steps were already executed by somebody and the device already contains the final project When pre programming a device in this way an XIF file should always be generated as well after the device was programmed and this XIF file should be delivered together with LOYTEC electronics GmbH L Vis User Manual 110 LOY TEC the device If this was not the case and the n
140. e than one source and the time is not the same Select the desired source for time synchronization from the list Update Scheduler Config This dropdown list is used to set the behavior of the configuration software when a project was downloaded to the device or uploaded from the device and there are local schedulers configured Depending on the setting here the configuration software will either automatically synchronize the scheduler configuration data ask the user if the configuration should be updated or not update the configuration in which case the user may manually update using the commands from the connection menu Keypad Button Size Specifies the desired size of the keypad buttons on the display width x height in millimeters To access trend and event logs created by the respective controls a dedicated FTP access is available Using the user name and password specified here it is possible to log in using an FTP client and download the required data files 13 1 10 LCD Backlight This slider is used to set the brightness of the LCD backlight when the unit is active Good settings are between normal and bright where the bright setting consumes more power The life time of the backlight is not significantly affected by the brightness setting 13 1 11 System Strings Pressing the button Setup System Strings opens another dialog where a number of strings can be translated to match the requirements of the project These strings are
141. e timeouts apply A sub menu item Upon selection the connected sub menu will be None Yes ER shown for further navigation A combined item The connected page s will be shown in the os Ves background while the connected menu will open in the foreground for further navigation This type of item can be confusing for the user and should be used with care Table 8 Function modes of a menu item Always add a return item as the last item of your sub menu or the user will not be able to navigate back to the parent menu In the root menu a return item is used in a different way If a return item is found in the root menu the device will use it to connect the system setup sub menu to it making it the setup menu item This is done so that the user may provide a menu item for the built in setup menu and configure it through the normal configuration software just like any other menu item If the project does not provide a return item as the last item of the root menu and the built in setup menu was not disabled in the project settings a default setup menu item will be created automatically However this item will most likely not fit the design of the other items in your root menu so it is a good idea to always provide this item in your project 8 3 1 Menu Item Properties Version 3 1 On the Common Properties page a menu item can be assigned a text as well as an icon bitmap Obviously at least one of them should be set to make a us
142. e to Focus Loss LOYTEC electronics GmbH L Vis User Manual 144 LOY TEC e For the nvoSwitch value data point set the NV Update Flags value to Focus Loss adjust the Value Range to values between 0 and 100 and set the Acceleration to 2 The configuration now looks similar to Figure 22 The project can now be loaded into the L Vis device bau i be Erari Ciir Lliage Wie Lortral Han Maru Digi himan Meere AA rs eat a Feud Mido Wa Range bgu Flesh dp Are D Temes Plage Corral Dita Port Wiis la integer Meta Mes Page 4 Coni 16 De 4 A Pe Figure 22 SNVT_ switch on a numeric control 14 2 Example 2 Using Data Point conversion and Hiding of Pages _ Version 3 1 This example will use an input value of type SNVT temp p It will provide the temperature value on a bar graph and a numeric control The data will be shown in two versions one for degree Celsius and one for Fahrenheit The two display versions will be placed on different pages The example will show how to use the hide flag n order to load the project into the L Vis device with the localized configuration The example walk through description assumes that a dynamic network variable nviTemp of type SNVT temp p is already created on the L Vis device e Create a menu item and add a page to the menu item Name the page e g to Temp Example C Add a text control to the page and enter a header text for the page e g Temperature e On the page
143. e value at a time the entered default value will apply to all other data points which reference the same data object as well The entered value will be run through the value translation to determine the resulting value for the underlying data object and this value will be distributed back to all connected data points to maintain consistency Only if the data point is marked as constant value this process is not done see next paragraph When adding a constant value data point set the constant value flag before entering the desired constant value in order to not disturb the default value of the non constant data points If the Constant Value checkbox is set the point is marked as constant and the entered default value will not be overwritten by values received from the network or data entered by the user In addition you may set differing default values for data points which reference the same underlying data object if the data point is marked as constant value Constant value data points are often very useful together with push buttons of any kind Create two or more push buttons for example three text controls with the static texts LOW MEDIUM and HIGH enable push button mode and request to always send the current value then add a temperature output data point to each of the three controls always referencing the same data object Now you can set the data points to constant value and enter different values for each of the three points
144. ect Virtuelle Funktionseinheiten and click on Neue Virtuelle Funktionseinheit Figure 15 W ALES 3 0 LYSE Subsystem LLEIS Datei pemben giihi Extras Ferier 2 Harik E ore t Sy OY a Prad ten iuran ts Arbeiteplate x hb Projekte 0 hb Dema AD Witersystenve 1 e Setrererkvariablen 12 2 Funktionscinheiten 13 Vetuelle Funktionseinhriten 00 Parameter 0 iy Verrkimangen 0 E g Tih Router 0 QQ UntersysLere 0 Ga Kan le 1 E Ger teworlegen 5 HAG Verbindungevodlagen 1 if Flonktorsets 0 We onen Te one na 12 05 Figure 15 Alex main window Enter a name in the dialog Figure 16 and press OK Version 3 1 LOYTEC electronics GmbH L Vis User Manual 125 LOYTEC Funktionseinheit Meu x Allgemein Mame Virtuelle Mame der virtuellen Funktionseinheit WIFCJEWE Allgemein Virtuelle Funktions einheik Funktions L I5 1 Eigenschaften Anzahl der zur Zeit angelegten Yariablen Beschreibung P Maximale Anzahl an Netzwerk Variablen AAA Interface Wersion m OK Abbrechen bernehmen Figure 16 Virtuelle Funktionseinheit dialog Open the Netzwerkvariablen collection in the tree view and select Neue Netzwerkvariable Figure 17 ALLX 3 0 LVISDemo Subsystem 1 LV1S L VIS 1 Datel Gearbeken Anscht Eitras Fenster Part EJ Chords OS XK oF TI Pfad LVISDemo Subsystem LILVISIL YIS 1 AA
145. ed select the desired scheduler point in the tree view to see a preview of the corresponding configuration data The following options concerning the controls appearance can be set Width of scroll bars This number specifies the width of the scroll bars if enabled The width should be chosen such that the bars are easily selectable by the user touch and drag but not consume too much space Scroll daylist This option enables a scroll bar for the list of days left column If the number of total days s known and the control is sized such that all days are visible the scroll bar may be disabled to save space in horizontal direction Scroll time table This option enables a scroll bar for the time table right column Since the number of entries in this table is usually not known it is a good idea to keep this option checked However special applications may benefit from the possibility of removing the scroll bar and gain even more space Compact header This option causes the control to generate a one line header placing the scheduler name left aligned and the effective period if enabled right aligned If the font is too large or the scheduler names are too long there may not be enough space and the effective period must either be disabled or shown on a separate line Don t show effective period This option can be used to hide the effective period altogether Useful to either save space or to make sure that the effective period
146. ed into your network depends on the network management tool in use and the way the configuration software is run The available choices are detailed in the following sections 10 1 1 New Device NOTE Integration of a new device normally starts with an empty device no project loaded Integration of a pre programmed device is explained further down To follow the procedures in this section make sure there is no project loaded in your device This can be done by setting the CLEAR jumper starting the device and removing the jumper again Also if the device was previously used in another network it is a good idea to also reset the network configuration data by pressing and holding the service button while the device boots up This has to be done in an extra step when the CLEAR jumper is not set The integration procedure may vary depending on the type of network variables used in the project The following sections detail the three possible variants 10 1 1 1 Dynamic NVs Version 3 1 In case your project uses dynamic NVs only there must be a network database system which provides support for dynamic NVs The configuration software may be run in plug in mode as well as in standalone mode since no complicated database updates are required in this scenario The followings steps will be required to integrate a new device e Create a new device in your database using the provided device template for the L Vis device you are using FT 10
147. ed to LNS connections due to an optimized file transfer protocol LIMITS e Only works when the device is commissioned A download of a new project which changes the static interface of the device will therefore break the connection since the device will have to reset 1ts CEA709 network configuration in that case The device must then be re commissioned in the network management tool and the connection must be re established e Especially in FT 10 mode project downloads can still be slow The same is true for firmware downloads If possible the TCP IP connection method should be used for such tasks Transfer speed is considerably improved when there are no routers with limited buffer size between the PC and the device Routers which are able to handle large packets 254 byte will have no real impact on the transfer speed Routers which allow a maximum packet size of 64 bytes only will degrade the transfer speed e Only network interface hardware from LOYTEC can be used for this type of connection Any LOYTEC NIC may be used to run the configuration software that is the software is not registered to specific network interface hardware 2 2 2 BACnet Devices To configure BACnet devices the software is always run in standalone mode and a connection to the device is made over TCP IP The PC must be able to establish an FTP connection to the device check firewall rules if necessary Version 3 1 LOYTEC electronics GmbH L Vis User Ma
148. ee view and select Add Item from the context menu A new menu item is created and connected to the menu object The new menu item is automatically selected so that you may browse the property pages and see what you want to change The name of the item object can be changed in the Name box of the General property page This changes the name of the object in the object tree and has no effect on the appearance of the menu item on the device To change the text of the item itself go to the Common Properties page and change the contents of the Text box The display in the preview window changes as you type so you can immediately see the results You may want to change the font to the 12x16 ROM Fixed R font so you get a larger item which is easier to select on the touch screen The menu item object s described in detail in section 8 3 Repeat the steps above to add another menu item and call it Setup Again change the Text of the item to read something like Setup and change the font to make the item a comfortable size This item will be used to enter the devices setup menu The device will check the last item of the root menu and see if it has any pages or sub menus attached to it If the item has no further objects attached this is called a return item and is located at the last position in the root menu then the device will connect its setup menu to this item If the item is used the device will create a default item to reach the setup
149. emote Calendar from the context menu in the data point list to bring up a dialog to create a new remote calendar point e Enter a name for the calendar point a name for the input NV which will be used to connect the calendar from another device to this data point and select the desired functional block in which the NV should be located e Press OK to create the calendar point repeat for more calendar points if required There should be one calendar point for each device from which schedule data is viewed since the calendar point will carry the information about exception days used in the schedules e Select the data point folder named Scheduler and use the context menu to create a New Remote Scheduler point Enter a name for the data point a name for the input NV which will be used to connect the point to a scheduler server and select the functional block in which the NV should be located e Press OK to create the scheduler point and repeat for additional points as required Each of the created scheduler points will later provide access to the configuration of the scheduler unit to which the scheduler link NV was bound in the network see below On CEA709 devices there is one extra step to take before the new data points will be operational The new static input NV representing the remote calendar on the local device this NV is normally called nviCalLink needs to be bound to the output NV called nvoCalLink located n the Calendar f
150. ent placeholders to display date and time in textual form The format string conforms to the ANSI C strftime function and is detailed in the Date Control appendix of this document On the property page of the Date Time Control a format string wizard is available for the user to create a correct date time format string without knowledge of the details Expert users may also look up the available placeholders in a C programmers manual for the strftime function Table 5 Usage of the common text field for visible objects Also available on the common properties page are fields to enter the screen position and size of the selected object if the object 1s a control However position and size of controls are usually modified directly in the LCD preview using the mouse or the cursor keys For more information about position and size of controls please see step 5 of the tutorial The checkbox Auto Resize is normally turned on so that controls which support t will resize themselves automatically to accommodate the largest content they need to display according to the elements in the mapping table The checkbox may be turned off for text controls to prevent automatic resizing and set the desired size manually Manual size for text controls is most often used when the selection area should be larger than the longest text In this case the text is often also center aligned using the buttons to the right of the text input field Another case is
151. erse effects on the network performance and the performance of the devices in the loop so special care should be taken to avoid such setups LOYTEC electronics GmbH L Vis User Manual 138 LOY TEC 13 11 User defined Fonts NOTE Every device has a set of three basic fonts which cover the ISO8859 1 Latin 1 code set in three different sizes To extend the available choices the configuration software and the device support user loadable fonts in most common formats including TrueType Typel BDF PCF and others The L Vis configuration software is shipped with a set of selected freeware PCF fonts to cover Western ISO8859 CJK Chinese Japanese and Korean and also Unicode UCS16 character sets These should cover your immediate needs for a large number of languages The provided PCF fonts are fixed size fonts meaning that each of them is designed and optimized to a specific resolution Most fonts are therefore available in a number of variants starting at very small sizes up to about 24 pixel resolution For larger sizes or other designs you may load vector fonts as well in which case you will have to specify a font size n points 1 72 inch and the configuration software will render the font in the desired size for you If the loaded font file 1s a font catalog for example ttc you may also select the desired face which should be rendered It is recommended to use fixed size fonts like the provided PCF fonts for small siz
152. erted into hexadecimal on the control so the display format and the input keypad should use the same number system The check box Password Input Keypad may be used to enter a PIN code The keypad starts out empty instead of showing the current control value and for each digit entered it only shows a star It is possible to add static text around the value defined by the format string If you generate the format string using the wizard first generate the format string and then switch to the common properties page and add the static text before and after the format specifier in the text field Any text can be entered with the exception of the percent sign since this character starts a format specifier The exact format of this string is described in section 16 1 of this manual To output a percent sign enter in the format string 8 5 5 Bar Control Version 3 1 Bar controls are one of the more complex and versatile control types In combination with other controls they can be used for a large number of applications which are not immediately obvious such as a moving sunblind or an arbitrary area on the screen which can be filled with a variable color useful to mark open windows in a building for example The basic application of a bar control uses a scale on one side of the bar including tick marks If the value represents a temperature a small dot is sometimes included at the lower LOYTEC electronics GmbH L Vis User Manual 6
153. es up to 24 pixel resolution and load vector fonts for large sizes Since the L Vis device has a limited LCD resolution and cannot support anti aliased fonts due to hardware limitations a small rendition of a vector font will not look as clean as a fixed size font which was designed and optimized to a specific target resolution 13 11 1 Font File Location When a project contains a user defined font 1t is necessary to have access to the original font file when working with the project This is guaranteed as long as only the pre installed fonts are used since they are located in a known place on every installation of the configuration software However if fonts from an external source are used they too must be available whenever the project is loaded and modified and the user has to make sure to deliver the font file together with the L Vis project file if the project is to be edited on a different PC where the font may not be available at the same location To locate the original font file the configuration software will automatically try the following locations in the given order until a suitable font is found e The full path from where the font was built the last time e The directory containing the project file e The fonts directory of the configuration software installation If the font cannot be located in any of these places the user is asked to provide an alternative font file Based on the above search order the easiest way
154. es still open go through all menu item objects and enter each items text in the text field Choosing a medium sized font like the 12x16 ROM font will make it easier to select the menu item on the touch screen If the item text does not fit the width of the menu don t worry about it for now The required menu width will be set at a later step when all menu items have their final text assigned While you are at the common properties page you may also load an icon for the menu item which will be shown to the left of the item text Go back once more to the menu objects of your project and open the Menu Page property page For each menu set the Container Width such that the longest item text fits the menu If your items use graphical icons as well you may need to adjust the width reserved to the left of the item text such that the widest icon will fit In case the menu contains more items than fit on the screen make the scroll bar wider so that the user may easily grab and drag it with the index finger The default width of the scroll bar is designed to look good for menus which do not need a scroll bar Now go through your pages and lay out the controls as desired While a page is selected go to the Common Properties page to select a background bitmap for the page or go to the Color page to select a background color That s all you should need to configure for the page itself at this time Note that each page for which you set a full page
155. etwork management tool needs an XIF file it may be created after the device was programmed using the following procedure e Run the configuration software in standalone mode and connect to the pre programmed device for which you need an XIF file e Press the Upload Configuration button from the tool bar to upload the project which is currently stored in the device e Use the Export XIF command from the Tools menu to output the required XIF file Now integrate the device like any other CEA709 node using the XIF file If the network management tool supports plug ins and the new device should be configurable in plug in mode re run the plug in registration for the L Vis configuration software so that it registers itself on the new device 10 2 Device Replacement This section describes the steps necessary to replace an already integrated device with a new device using the same project as the old device Depending on the situation this may not be a trivial task The procedures for the possible situations are detailed in the following sections NOTE The following procedures assume that the L Vis project file is available to the PC which runs the configuration software If this is not the case the project must first be uploaded from the old device and saved to a file 10 2 1 Dynamic NV Projects Devices using dynamic NVs only are relatively easy to replace since the device may physically be replaced right away and the configuration
156. ew state should now be displayed on the text control using the texts which you specified in the mapping table To change the value select the bar control and move the bar up and down The current value will be sent out received back in and should be visible immediately on the numeric control 2 4 Quick Start Tutorial BACnet This tutorial describes the steps to create a first demo project and load the project into a BACnet model like the LVIS ME200 The tutorial assumes that the configuration software is already installed on the PC At least one other BACnet device should be available in the network and provide some server objects which can be displayed on the L Vis 2 4 1 Add the device to the network NOTE The first step is to integrate the device into the network Power on the device and wait until the boot process has finished Open up the menu and go to the TCP IP setup page to set a suitable IP address network mask and gateway for the device or turn on DHCP to enable automatic IP configuration if available in your network Switch to the BACnet setup page and enter the desired device ID number If the device is connected via MSTP set the correct baud rate and node number if connected via BACnet IP set the desired port number the default should be OK in most cases The device can only operate either on MSTP or BACnev IP The currently selected interface is shown at the bottom of the BACnet setup page for your reference To sele
157. f BACnet Objects 200000000000000000000000000000000000000000000000000000000000000 129 13 AQvanced Topies ss ER 130 13 1 Project Settings ant sveccescavescesbavacessusuagssebavaaneteavoncssdaenascseasaavevaerestassaseete 130 IS Page Protection ee aan unseren soneoo 130 1 321 2 Lime OU Y AMES een 130 132123 Systent PACS neue 130 IE Remo Nee see ee see 131 EES S 0 na EEA 131 ISO OEM DIMAS are regt 132 13 17 8ySIe D C 0018 35 east a ar ee er 132 IET System A he as ee 132 FE I DA EI O ee ee 132 TS TIO MCDB aCe NG as nenn 132 EE A seien 132 ESA A A a a a a 133 13 2 Access Controls er Eee 133 133 Undoy Rede aan EEA an Rene nenn 134 134 AAA nnd 134 SAL Abonnent Fune ons ale 134 15 4 2 Make Same Str sh cea en ie 153 IS opaco Br erste ee 135 13 5 Pind Similar Objee 8 aan aa Ru 135 13 6 Preview and Edit Mode 135 13 7 Remote Network Interface una al 135 13 5 Local Data Point Capac iii inician ea dadas 136 13 9 Device Model and Firmware cocic nanicnnocanacanininacadocanocininanicadonacandanadaccndan anacino 136 13 10 Avoiding Update LOODS vssosiccc noaiinicionioni nanccanoconcandonocionendanionendonco a d cancnacadacic no 137 13 14 User defined Fonts ae 138 13 215 Font Pile Location einsehen 138 PSV DORE RECON oa 138 P3013 PERES OM a dia 139 13 12 Using Color BIEMapS sans a a O Ea EE i 139 LOYTEC electronics GmbH L Vis User Manual Version 3 1 8 LOYTEC PE MAMI PCS AA o RR IRRE 141
158. f the device replacement procedures to be executed changing the network configuration usually means to restore a database backup which matches the configuration of the current device If the device uses static NVs only and the bindings which were originally used together with this project were saved and are available in a file the network configuration may be adjusted by completely removing the old device definition if any executing the integration procedure for a pre programmed new device followed by a binding import to restore the original bindings 10 4 3 Recover from a failed Update When a project update including a change of the static interface fails there may be some extra steps necessary to restore the last working setup or to resolve the original problem and finish the upgrade Which one to use depends on how far the upgrade procedure ran Version 3 1 LOYTEC electronics GmbH L Vis User Manual 116 LOY TEC 10 4 3 1 Failure before Database Update If the procedure failed before the database update that is the device template in the database 1s still the old version the device must be rolled back to the last project as well so that the database and the device match again The recommended procedure is detailed below e Follow the standard procedure for device replacement as appropriate for your project but do not run the configuration software in plug in mode at any time Only use the software standalone including any other
159. f your calculations Using the assigned variable names the user may now enter a formula directly below the list As you enter the formula it will be parsed and the resulting sequence of calculations will be displayed in a list at the right of the property page This list shows your formula in reverse polish notation RPN also known as postfix notation as used by many scientific pocket calculators Users of such calculators will be immediately familiar with this list and may find it more convenient to construct the formula using the list at the right instead of the input at the bottom To learn more about postfix notation there are a lot of resources and articles readily available on the internet When the formula entered at the bottom is still incomplete and does not yield a meaningful command sequence the list showing the RPN equivalent will be empty This allows the user to immediately see if the current input is valid or not The operators AND OR XOR amp lt gt lt gt can be used instead of the explicit function calls Further it 1s possible to use parenthesis to define the precedence of the operations The buttons and input fields in the middle of the page are used to directly edit the formula using the reverse polish notation To add a variable to the stack either double click the variable in the list at the left or select it and click the Add Variable button To add a constant value to the
160. face If something goes wrong during this process all dynamic NVs on the device may be lost and must be recovered using another procedure You are advised to have a recent backup of the database ready in case the recover mechanism built into the configuration software fails as well For network management systems which do not support plug ins the new project must be loaded in standalone mode and a new XIF file must be generated after the download completed The network management tool itself must then provide a way to upgrade the Version 3 1 LOYTEC electronics GmbH L Vis User Manual 114 LOY TEC NOTE static interface of the already integrated device and take over the existing bindings The recommended procedure 1s as follows e Run the configuration software in standalone mode and connect to the device preferably using a TCP IP connection e Load the current project from a file or from the device and modify it as required adding or removing static NV data points e Download the new project to the device A warning appears stating that this operation will change the static interface and that the configuration software will not be able to automatically upgrade your device in the network e In case you are connected over CEA709 another warning will tell you that the connection will be lost after the download because the device will go to unconfigured state due to the static interface change It is therefore recommended to use
161. for example 18 22 and 24 When the user now presses the LOW button the value 18 will be sent out When he presses the MEDIUM button the value 22 will be sent The Persistent option is used to request that the current value of the data point should be preserved across a reboot of the device and be used as the new default value until updates are received Since the value which will be saved is the value of the referenced data object this option will also affect all other data points which reference the same data object The persistent option is useful for output data points which need to be sent out after system boot System Startup flag is set but are controlled by actions or math objects instead of direct user input Such data points must preserve their last calculated output value across the reboot but there is no control which would normally cause the output value to be stored when the user finishes data input Checking the persistent flag will solve this problem The NV Timing section is used to control the timing of update messages on the network resulting from this data point A minimum and maximum send time may be specified for output data points a receive timeout may be specified for input data points A value of 0 always means unlimited The individual parameters work as follows e MinSend At least the specified amount of time has to pass between two successive update messages on the network If the device delivers mode update
162. g data source but the new name is used to create a copy of the original data source and the selected item is reassigned to this copy The function keeps track of the copies it creates and ensures that each unique source is copied only once For example if more than one selected entry references the same original data source one copy will be made of this source and all entries will be reassigned to this copy As a result data points which referenced the same source before the duplicate operation will reference the same source after the duplicate as well only the reference will be to the copy of the original source 7 2 5 6 Create Static NV Server Object Version 3 1 This operation allows creating local data objects from remote data objects Depending on the network technology used by the device it is possible to create static NVs which are complementary to referenced external NVs or to create local server objects which are complementary to an existing client mapping The operation works in the same way as duplicate and reassign except that it creates new data sources based on existing remote sources instead of existing local sources LOYTEC electronics GmbH L Vis User Manual 47 LOY TEC 7 2 5 7 Remove Data Point This operation removes the selected data point objects from the project It is useful to remove a number of data point objects in one step instead of going through the object tree in the tree view and removing each data p
163. ged are shown with a small ACK button at the right end of the alarm entry Pressing this button will send an alarm acknowledgment back to the reporting alarm server and change the color of the button Once the server received the acknowledgment it may send an updated alarm status and the button or the entire entry may disappear The information displayed for each alarm is the date and time the alarm was first reported the type of alarm the current state of the alarm and in the second line an identification of the alarm source as well as a description and possibly the value which caused the alarm Depending on the underlying network technology and the fact if the alarm was reported by a local or by a remote alarm server not all of this information may be available so that entries may be missing some of the information printed on the second line The information in the first line is always available and will always be printed If an action object is connected to the alarm list control and the action trigger is set to value update the action will be executed whenever a new entry is added to the alarm list This can be used to switch to a specific page action show page or write a value to a data point action update data points to notify the user of the new alarm list entry The following colors may be set for alarm list controls on the Color property page Element to which the color applies rained Button graphics and pag
164. he new data Note that this will also affect all other schedules running on the same calendar 6 3 Setup Menu Version 3 1 All devices come with a built in setup menu which is used to set device specific parameters such as the devices IP address control network settings or date and time zone These settings are related to the installation of the device and are usually configured at installation time Once the device is installed and a project 1s downloaded to the device the built in setup menu may be hidden so that it is no longer accessible to the users of the device Alternatively access to the setup pages may be protected by a PIN code Both options are available in the Project Settings dialog which can be accessed from the File menu in the configuration software The standard setup menu always contains the following pages e TCP IP On this page the IP address network mask gateway and optionally NTP server addresses for time synchronization can be configured Alternatively the device can be instructed to get the required settings from a DHCP server in the network automatic IP configuration Changes on this page will not be effective until the device is restarted e Date Time This page is used to set date and time as well as the current time zone Always adjust the time zone first and then set date and time to the local time There are various ways to synchronize the time with external time sources The current time sourc
165. he device 2 2 Connecting to the Device There are several ways in which the configuration software can be run and used to configure a device While this is straight forward for BACnet models it is important to know the advantages and limitations of each method for CEA709 devices 2 2 1 CEA709 Devices CEA709 devices may be configured in several different ways e Through LNS software run as LNS plug in e Viaa TCP IP connection using FTP e ViaaCEA709 connection FT 10 or IP 852 Each of these methods has some advantages and some limitations in what they can do Please see the following detailed description of the individual connection methods 2 2 1 1 LNS Connections This method connects to the device from within the LNS based network management tool The software is run as a plug in and all communication with the device is done through LNS meaning that you can use any network interface which is supported by LNS If your device is integrated into the network using an LNS based tool your device is managed by LNS and you need to add or remove static network variables from your project or otherwise change the static interface of the device you must use this connection method to download your project since the configuration software needs to do several adjustments to the LNS database during this process Version 3 1 LOYTEC electronics GmbH L Vis User Manual 13 LOY TEC If your changes to the project do not cause
166. he project needs to be loaded again so that the dynamic NVs which were not available the first time can be used The recommended procedure is a combination of the above two procedures e Follow the procedure to replace a device with static NVs to prepare the new device with the original project When the project is loaded from the file a dialog will appear and list all dynamic data points in the project stating that they could not be found on the device e Finish the dialog by removing all data points listed Since the device does not yet contain any dynamic NVs these data points cannot be used for the moment e Download the modified project into the device but do not save this project over your original project Remember that it has all dynamic NV data points stripped You may save the project to a different file but this is not necessary e Now take the device and execute the procedure for replacing a device using dynamic NVs that is physically replace the device and continue with the procedure If an XIF file or a device template is required for the replacement use the same XIF which was used to initially integrate the device or use the same device template as the device to be replaced Since the device already has a project loaded which matches the final static interface t will be possible to replace the device without changing the static interface in the database Commissioning the device will create all the dynamic NVs stored in th
167. he speed at which value updates are sent out during ramping is controlled by SCPTminSendTime 11 5 3 Relay LCD Backlight control The relay object implements a LONMARK Lamp Actuator object according to the LONMARK Functional Profile 3040 It receives the input value of type SNVT_ switch in the variable nviSwitch and sends out a feedback of the current state in nviSwitchFb The output network variable reflects the state of the relay input of the old LVIS 3ECTB device The newer touch screen models do not provide a relay and the lamp actuator object on these models is used to control the LCD backlight To overrule the value which is adjusted in the L Vis Plugin Software the state part of the nviSwitch network variable has to be set to 1 In that case the value part of the network variable controls the brightness of the display from 0 to 100 If the state part of the variable is set back to 0 again the backlight automatically uses the values which are adjusted in the L Vis Plugin software This feature can be used to adjust the backlight in relation to the ambient brightness which could be measured with a sensor On newer firmware revisions the backlight may also be controlled via an internal system register which 1s available as a data point and may be used freely across the project This is the preferred way of controlling the backlight 11 5 4 HVAC Temperature Sensor Version 3 1 The temperature object implements a LONMARK Tem
168. hich are currently unused the Use column shows 0 may be removed from the list New objects may be created in the selected folder by pressing the New button to the right of the list or via the New command in the context menu The list may be sorted by a click on the desired list column When an entry is selected detailed property information is shown below the list in the property view LOYTEC electronics GmbH L Vis User Manual 93 LOY TEC 9 2 3 Property View 9 2 4 Buttons The property view is the area below the data object list and is used to display detailed information about a selected data object Some of the properties may be modified in this area while others marked with a lock symbol are read only If more than one data object is selected in the object list the property view shows only the properties which are common to all selected objects At the right side of the window are a few buttons to create new data objects as well as duplicate and remove objects which provide the same commands as are available through the context menu in the object list There are two buttons which provide additional functionality e Cleanup This button scans all data object folders and removes any objects which are currently not referenced by data points in the project e Find This button tries to find the first reference of the selected point in the object tree of the main window and 1f available selects the corresponding object
169. hich should be available on the device Each local scheduler data point created in the data point manager will connect to one of these scheduler objects There may be more scheduler objects available on the device than are actually used at a certain time It is a good idea to have some spare scheduler objects ready in case another scheduler is needed e Number of daily schedules This is the maximum number of schedules supported by each scheduler object This number must at least be 7 since a scheduler always needs to provide one schedule for each day of the week default weekly schedule For each special day defined by the calendar an additional daily schedule is required to support it e Entries in Time Value table This is the total number of entries in each scheduler defining a value template that should apply on a specific day starting at a specific time the time table e Number of value templates This is the maximum number of value templates supported by each scheduler e Data size per value template This specifies the buffer size reserved to hold the data for each value template More data points or bigger data structures require a bigger value buffer e Max number of data point maps Specifies the maximum number of individual data points that this scheduler is able to control As can be seen from the above list it is not easy to configure a LonMark scheduler object There are many technical parameters which need to be set and
170. hich will be replaced by a string taken from a mapping table or a connected string data point For static texts use a text control and fill in the static text in the text field without using a s placeholder The s placeholder conforms to standard C rules and may include additional format modifiers between the and the s lt number gt A number following the sign forces a field with for the string of at least the given amount of characters If the string is shorter it is padded with white space at the left right justified within the given field A dash preceding the field width means the string should be left justified inside the field padded to the right Text Control lt number gt A decimal point followed by a number is interpreted as the maximum length of the resulting string Format string which may contain one placeholder for a floating point value for example of g or e To display a hexadecimal value the placeholder x may be used together with the option Convert Data Point Value to Integer which is available on the Numeric Control property Numeric Control page detailed below There are a number of format modifiers available for the expert user to tailor the output of the numeric control Novice users may use the format string wizard on the Numeric Control property page to construct a suitable format string without knowledge of the details Date Time format string which may contain a number of differ
171. his section for example mathematical objects or alarm generators These objects are not control objects because they do not provide a user interface They have no position and size coordinates or other visual properties Depending on the data point objects connected to the control the control will either show static content only show dynamic content based on values which are received from connected input data points or become selectable and accept new values from the user which are then written to the connected output data points Controls which accept user input are called input controls The following sections describe each of the available controls and their properties 8 5 1 Text Control Text controls are used to display one or more lines of text The text is entered on the Common Properties page in the Text area as explained in the section about the common property pages Dynamic text from a mapping table or from a connected string data point may be inserted at the s placeholder otherwise the text remains static On the Color property page the following colors can be set for the control Element to which the color applies De Text color This color may be overridden by color specifications from a un connected mapping table Frame drawn around the text if the control is selected Also used to draw the Selection grid of the drop down list from which a new text element is chosen input controls only Backend Color ofthe con
172. hould the action be considered for execution e Condition Once triggered under what conditions should the action be executed and how if at all should it be repeated When a new action is defined it is important to think about these three components and make sure the selected choices actually make sense Each of the above properties may be controlled individually but not all of the possible combinations will actually make sense Examples of good and bad configurations and how to avoid the bad ones will be given later on 8 8 1 Action Properties Version 3 1 Actions are objects which are not visible on the screen of the device so they do not use any of the common properties like font position size or color Aside from the General properties which apply to all objects actions are configured on the Action property page This page is divided in two sections The top half is used to define the action that should be executed when it will trigger and the conditions under which it will be repeated The bottom half is used to set options which may be required for some of the actions From the first dropdown list select the action you want to execute Currently available actions are e Show menu Show the current menu just like performing a press and hold Operation on an empty spot on the display Useful to build menu buttons which show the menu when pressed e Show page Jump to the specified page To select a page drag a page and
173. how page action or the name of the selected mail template for the send mail action To set a new page drag and drop the desired destination page on the action in the tree view To select a new mail template use the button next to the link field 8 9 Collections A collection object works like a folder on a file system It helps the user to organize objects in groups Collections can be placed on pages to group objects together and manipulate them as one unit It s also possible to create nested collections to build complex macro blocks which consist out of a number of smaller building blocks At the bottom of the main tree view is a base collection where objects can be collected which work invisibly in the background without a graphical representation on the screen and without a direct relation to any object on the screen for example alarm generators data point connectors or mathematical objects However it is recommended to keep all objects which are required for a specific control or control group to function together on the same page This way the page continues to work when it is copied or moved to another project because the required invisible objects are copied together with the page The base collection outside of the main menu should only hold objects which are related to the device rather than specific page functionality 8 9 1 Collection Properties Aside from the properties on the General property page which apply to all obje
174. iate All values are immediately transmitted to the underlying data object This provides direct feedback to the user while the control is still in input mode and the user is still modifying the value Currently really only useful for bar controls and controls which use the keypad since the keypad has and keys which send out intermediate values e System Startup The checkbox System Startup should be checked to instruct the device to update the value on system startup If the underlying data object is a value output the default value or the last stored value will be sent out if it is a value input the device will try to request the current value from the sender Both actions can only be successful if the underlying network technology supports them In cases where the requested operation cannot be executed it is silently ignored For example if the polled flag of an input network variable is not set the device will not be able to fetch the current value from the sender since it has no knowledge of the senders network address and therefore can not send a request for a value update e Value Changes Only This option causes the data point to forward updates only if the value actually changed It is very useful to avoid unnecessary operations caused by repeated updates with the same value provided that the data point does not represent an event in which case all updates must be processed and this option should not be used e No Invalid Up
175. ic objects The operation results are exchanged between the mathematic object and the bitmap controls using a register 15 3 Animated Bitmaps The project Solution examples manual lcp contains a Animation Demo page di Solution examples manual 1 L Yis Configuration File Edit Model Firmware View Help Oa a se a 7 Subsystem 14 415 ONNET Page Rank Meno Example Pages Animation Frample 7 Root Menu Menu Navigation General Common Properties Mapping Data Point Color Meru Page Example Pages 2 Switch Example Page Menu 7 Sunblind Example View Timeout O sec Container Width D F Locked Page Bitmap width 76 tT Label mibe Fage TAP Switch Bitmap Defaul Page mapping Enable Dackground whegtnable dE animated bitmap mapping ir rRecCounterValue D LOYTEC Back Icon www loytec com f Show Main Menu Split Example Counter Demo Selup Menu Global Objects 33 Math Objects Counter i Increment by 10 i Decrement by 10 i Merge Bits Scrollbar width Fush to start stop lt For Help press Fl Menus 1 Thema 3 Pages Controk 44 Datapninte 41 Gwe 134 Figure 38 Animation Demo configuration The animation demo shows how to generate animated bitmap controls A bitmap control in push button mode starts and stops the animation The animated bitmap is built of a bitmap control together with a mapping table The input for the animated bitmap is generated by
176. ice must be added to the channel on your configuration server which will then contact the device and set the channel wide parameters such as the time server addresses automatically The result is displayed at the bottom of the CEA852 setup page LOYTEC electronics GmbH L Vis User Manual 42 LOY TEC NOTE For security reasons enabling MDS with a new key will store and activate the key and then reset the input fields to all OOOO so that the current key can not be seen on the display Once the key is stored that way it may be enabled and disabled using the dropdown list even though the input fields always show 0000 Consider these fields to be used for input of anew key only The BACnet models provide the following additional page e BACnet On this page the BACnet device ID MSTP node address and baud rate for MSTP mode only and the BACnet IP port number for BACnet IP mode only can be set The currently active interface is shown on the bottom of the page 6 3 1 Custom Setup Menu NOTE Version 3 1 Starting with version 2 0 of the device firmware the project may use standard controls on standard project pages to set all system parameters like IP address date time zone and so on To do this create a suitable control and connect the system parameter which it should modify This way a project may provide a completely customized setup menu matching the design of the other pages in the project for example a localized Japane
177. ield e g Switch s e Add data points to the control To do this select Add Data Point from the context menu of the control Add an input data point for nviSwitch state and output data points for nvoSwitch state and nvoSwitch value A default mapping between the state input values and the displayed text is automatically added to the control e For the input data point nviSwitch state set the System Startup flag on the Data Point configuration tab e For the nvoSwitch value network variable go to the Data Point configuration tab configure the Default Value to 100 and set the Constant Value flag Set the NV Update Flags value to Focus Loss LOYTEC electronics GmbH L Vis User Manual 142 LOY TEC e For the nvoSwitch state network variable set the NV Update Flags value to Focus Loss The configuration now looks similar to Figure 20 The project can now be loaded into the L Vis device To change the state of the output network variable select the text control by operating the jog dial until a frame is displayed around the text control Select the control with a short click Now the frame starts flashing which signals that the control is in input mode Turn the jog dial to change the state Pressing the jog dial again deselects the text control d ler Msi 1011 LW le Configuration Del A Glut Diir Line Gmm Common Pc Happaig Daia Poni Lolo Tet a Hams Dech tend LILOYTEC Commari miej ic Bhan bart Fei
178. ing which matches the configuration of an empty L Vis device is 512 and must not be changed if the static interface of the device should stay at default configuration If the static interface is allowed to change the capacity may be increased to support up to 1000 NVs using the input field Max Number of NVs Keep in mind that an increased NV capacity requires system resources which may otherwise be used for the project so this setting should not be set significantly higher than necessary 13 9 Device Model and Firmware Version 3 1 When the configuration software is started in standalone mode and is not connected to a device the Model menu can be used to select the model for which a project should be created and the Firmware menu can be used to select the firmware version of the intended target device This enables the user to create or edit a project which is intended to run on an older firmware version even when the firmware version to use cannot be queried from the device The real time LCD preview is automatically adjusted to match the behavior of the selected model and firmware version so that the preview is always accurate down to the pixel level what you see in the preview is exactly what the device will display pixel by pixel When started as a plug in or connected via TCP IP or CEA709 in standalone mode the menu items to select model and firmware version are grayed out so that the firmware version cannot be arbitrarily changed
179. interface in IP 852 mode or the status or the remote network interface RNI in FT 10 mode IP 852 The LED lights green if the device is properly configured and member of an IP 852 channel The LED lights orange when the device is configured in a channel but is waiting for updated channel information from the configuration server In case of errors the LED lights red RNI The LED is dark if RNI 1s not supported by this device older devices do not have enough node IDs to support RNI The LED is green if the remote network interface is ready for connections and orange if the device is currently in use In case of errors the LED is red LOYTEC electronics GmbH L Vis User Manual 31 LOY TEC MSTP LED This LED shows the status of the MSTP interface if the device is operating in BACnet MSTP mode The LED is green for normal LVIS ME200 operation orange if there is no token and red if there are communication errors Table 3 LEDs and Buttons Version 3 1 LOYTEC electronics GmbH L Vis User Manual 32 LOY TEC 5 Interface Configuration 5 1 Selecting the Interface Both the CEA709 units and the BACnet units have two network interfaces and two different types of communication going on which should be clearly distinguished e Communications with the configuration software to read and write configuration data upgrade the firmware and retrieve diagnostic data from the device configuration e Communication with other
180. is never modified through this control ISO 8601 week This option instructs the control to adhere to the ISO 8601 specification to display the days of the week in the left column ISO 8601 defines Monday to be the first day of the week ISO 8601 date format This option instructs the control to adhere to the ISO 8601 specification to display dates which is a four digit year a two digit month and a two digit day all separated by hyphens YY YY MM DD The following colors may be set for schedule controls on the Color property page LOYTEC electronics GmbH L Vis User Manual 70 LOY TEC Element to which the color applies Frame drawn around the entire control if the control is selected Bar Bitna Background color of the header lines and color for deactivated P schedules day names in the left column and menu items Background of the day list and time table Color of the remaining background only a one pixel wide frame Bacto around the control where the selection frame will be drawn when the control is selected If the transparent check box is set all pixels using this color will be transparent Table 17 Color assignment for schedule controls 8 5 9 2 Access Levels Version 3 1 The right side of the Schedule Control property page is used to define access levels for various operations which may need to be restricted because they modify schedule configuration data These restrictions apply in addition to the general re
181. ist 1f the first character of the list 1s the caret then 1t matches any character not in the list For example the regular expression 0123456789 matches any single digit Within a bracket expression a range expression consists of two characters separated by a hyphen It matches any single character that sorts between the two characters inclusive using the locale s collating sequence and character set For example in the English locale a d is equivalent to abcd Most meta characters lose their special meaning inside lists but some characters must be placed at specific positions as pointed out below e To include a literal place it first in the list e To include a literal place it anywhere but first e To include a literal place it last The following special characters and symbols exist e The period matches any single character e The symbol w is a synonym for any alphanumeric character and W is a synonym for any non alphanumeric character e The caret and the dollar sign are meta characters that respectively match the empty string at the beginning and end of a line e The symbols lt and gt respectively match the empty string at the beginning and end of a word LOYTEC electronics GmbH L Vis User Manual 164 LOY TEC e The symbol b matches the empty string at the edge of a word and B matches the empty string provided it s not at the edge of a word A regular expression may be followed by one
182. k scanning to find other devices and their objects in the network and use them on the L Vis device without the need to manually enter device and object instance numbers Supports COV subscription and polling of remote server objects with automatic selection of the best method COV if available LOYTEC electronics GmbH L Vis User Manual 11 LOY TEC 1 2 Scope This manual covers the L Vis device family Currently available are the LVIS 3E100 CEA709 model and the LVIS ME200 BACnet model both equipped with a 320x240 color touch display using the standard 256 color VGA palette Version 3 1 LOYTEC electronics GmbH L Vis User Manual 12 LOY TEC 2 Getting Started 2 1 Installing the L Vis Configuration Application To install the L Vis Configuration software execute the setup program and follow the instruction of the installation wizard The setup program adds an entry for the L Vis Configuration software to the start menu For the use with LNS based network management tools it registers the configuration software as LNS plug in Before the LNS plug in can be used in a network management tool it has to be registered in the LNS project Please refer to the documentation of your network management tool how to register an LNS plug in in a network management project During the registration process of the L Vis Configuration software plug in LNS device templates are created for the FT 10 and IP 10L Ethernet versions of t
183. l not to the selection frame around it This is done so that for example the width and height of a bar does not change when you enable or disable tick marks or scale These are just seen as decoration which can be turned on and off while the area of the value display remains stable Adjust the properties of each control as you like or leave them at the defaults which should be fine for this demo Bitmaps will be added to the bitmap control in a later step 2 3 7 Connect the Data Points NOTE Version 3 1 At this point connect data points to the controls Especially for text and bitmap controls it helps to connect the data points early since the configuration of the controls property will depend on the data point connected you will see why this is the case in a minute To add a data point to a control select Add Data Point from the controls context menu A dialog will appear which is used to manage and select data points This dialog is explained in detail in section 9 for now we just use it to select our data points which should have been created for us already Select the folder Local NVs from the tree view at the left of the dialog There should be two items one for the input NV and one for the output NV we created earlier In case you created the dynamic NVs after you started the plug in the data points will not be there yet In this case close the data point dialog and push the button two positions right from the connect bu
184. l be used to enter the devices setup menu The device will check the last item of the root menu and see if it has any pages or sub menus attached to it If the item has no further objects attached this is called a return item and is located at the last position in the root menu then the device will connect its setup menu to this item If the item is used the device will create a default item to reach the setup menu but this will most likely not fit the design of your other menu items so it is best to always add a setup item yourself and configure it the way you want it to look Finally add a page to the first of the two menu items This page will be displayed when the user selects the first menu item from the root menu Open the context menu of the menu item right click on the item in the tree view and select Add Page In order to see this page right after the device started make this page the projects default page Open the context menu of the page in the tree view and select Set as Default The page object is described in detail in section 8 4 2 3 6 Add Controls to the Page Version 3 1 The next step is to place some objects on the page to view and control the values of the two network variables These objects are called controls in this manual since they allow the user to control the data points and display their current value A number of different control styles are available to choose from In this example we want to display the
185. l not be able to see any difference However due to the limited resolution dithering will be noticeable when viewing the images from a close distance which will be OK for photo realistic color graphics but might be unwanted for line art graphics which contain large areas of uniform color In such areas dithering to the exact color would not look as good as just picking one color from the VGA palette which is closest to the intended color If this is required it is best to design the graphics using the VGA palette and saving them in 256 color indexed format like for example 8 bit BMP or GIF It is important to make sure that the palette used by the graphic tool is in fact the VGA palette because when you later load the indexed color image into your project the software will make no further modifications to the image to guarantee a 1 1 match of what you designed and to avoid double dithered images resulting in poor quality see note below If color number 0 in your image does not refer to black or color number 255 does not refer to white as the VGA palette does the image will look different However you will see this immediately in the LCD preview window LOYTEC electronics GmbH L Vis User Manual 140 LOY TEC NOTE If you import an already existing bitmap and it appears in wrong colors the bitmap is already in indexed color format but uses a different non VGA color table most likely optimized to the contents of the picture A
186. l to the visible part of the project through which the schedules may be viewed and edited For this purpose there is a specialized type of control available the Schedule Control To use it create a control of this type on the page and connect one or more scheduler data points to it Please see the section about schedule controls for detailed information 9 5 Local Alarm Server To use a local alarm server create an alarm server point in the folder called Alarm On CEA709 devices there may only be one alarm server for the entire device BACnet devices support an arbitrary number of alarm servers There are two different types of alarming available The current software supports one type for BACnet and the other type for CEA709 devices 9 5 1 Intrinsic Reporting Version 3 1 BACnet devices support an alarm mechanism called intrinsic reporting In this concept high and low limits are specified for individual server objects and alarms can be generated by the server object and reported to an assigned alarm server when the value of the server object exceeds these limits for a specified time period Other devices in the network can register for alarm updates at the alarm server object which is a notification class object and display the current list of alarms as well as acknowledge individual alarms To set up a local alarm server and assign it to server objects the following steps are required e Create the needed alarm server points
187. lations can be done by the data point on the fly while passing values between the control and the data object This makes it easy to display for example a temperature from an input data object both in degrees Celsius and in degreed Fahrenheit side by side using two data points referencing the same data object but using different value translations It is important to understand this concept to understand what can be configured on the Data Point property page The key is that there can and usually will be multiple data points referencing the same data object 8 6 1 Data Point Properties NOTE Version 3 1 The following properties can be set on the Data Point property page Value Translation If the unit of the data point is known and there are some commonly used translations available for this unit one of the pre defined translations can be selected from the drop down list A custom translation can be defined by filling out the formula below the drop down list In this formula NV stands for the value on the network side Network Value that is the value of the data point and DP stands for the value of the data point as seen by controls or other objects which are connected via this data point The value translation of a data point can be very useful to modify a value on its way between a data processing object and a register or network value Using this facility simple data manipulation like the inversion of a state or the addition or s
188. ld be executed on a free sport on the display If the area of an input control is touched the control enters input mode and all further input is processed by the control The touch and move operation can be used to adjust values on a bar graph control or move the cursor in a trend control If executed in a free space on the page there are tree touch gestures which the device can react to e Touch and move up This will immediately bring up the navigation menu so the user does not have to wait for the timeout as is the case with the touch and hold action LOYTEC electronics GmbH L Vis User Manual 35 LOY TEC NOTE e Touch and move right This switches to the next page connected to the currently selected menu item If there is only one page connected this gesture does nothing it does not move forward to the next menu item e Touch and move left As above but switches to the previous page connected to the active menu item Touch gestures may be disabled in the project configuration in case the project uses a button only navigation through the pages 6 1 2 Calibration NOTE In case the touch screen has to be re calibrated select the command Calibrate Touch Screen from the command dropdown list in the setup menu This will show a black screen with a white cross at the top left corner of the display Touch the middle of the cross using the same viewing angle and the same touch device usually your index finger as the user
189. like any other menu Apart from the root menu the only other places where menu objects may be created are as child objects of menu items If a menu object is connected to a menu item selecting the item will show the connected menu This is called a sub menu To navigate back from the sub menu to the parent menu the sub menu must contain a return item which is a menu item object which has no further objects connected to it no page and no sub menu to show 8 2 1 Menu Properties NOTE A menu consists of a frame and an area containing the menu items The frame includes the menu title and the scroll bar whereas the item container is the inside space of the menu where the menu items are shown The assignment of colors on the Color property page to parts of the menu can be seen in the following table Color Name Element to which the color applies Frame Axis Title background and the frame around the scroll bar Bar Bitmap Scroll bar Container Scroll bar container background Background of the menu item area The background of a menu cannot be Background set to be transparent Table 7 Color assignment for menus On the Menu Page property page the width of the menu item area and the scroll bar can be entered The value is specified in LCD pixel the full screen width being 320 pixels The Bitmap Width parameter specifies how much space for icons to the left of the menu item text should be reserved if an item uses a bitmap This
190. list Execute lt action gt on lt trigger gt The following trigger mechanisms are available e selection The action is triggered when the control is selected A control is selected when the user touches the control and releases the touch screen while still inside the control If the user moves outside the control after the touch and releases the screen outside the control will not be selected e value update The action is triggered when the parent object the control or data point connector to which the action is assigned reports a new value for example because a new value was received via an input data point which is connected to LOYTEC electronics GmbH L Vis User Manual 79 LOYTEC NOTE NOTE Version 3 1 the control NOT to the action or when the user enters a new value using the control e state This is similar to the value update trigger but it examines the first data point connected to the parent object to see if it is a multi state value If this is the case the dropdown list next to the action trigger is initialized with the available states and the user can select a state from the dropdown list instead of entering a numerical value The action is triggered when the current state equals the state selected from the dropdown If the parent value is not a multi state value this trigger cannot be used e touch The action is triggered when the control is touched Note the difference to the selection trigger whi
191. low 2588er 47 71 6 Common Property Pages 48 TOE Genra Reet mee merely mao Merron Mn Me eeinte Mice MeCN a Serene 49 7 62 Common Properties pias 49 103 ClO se RN er ee erde 51 Object Description EEE 53 A sarah 53 82 Men BARDRREb Anne O R 55 8 2 1 Menu PEONES en 55 9 3 Menu Omi asrin o Eo Ra 55 So Mena eins Proper UES endana ana ee 56 A PAG N sas vases ad A a IAT 57 SA Pape Properties ee 57 853 Controlan 58 Sol TETE OT ee Per ORT meer tener Cre eee rr cer nlesin 58 8 93 2 PUMA p CE ONION ai 58 853 A emailen es 59 LOYTEC electronics GmbH L Vis User Manual Version 3 1 5 LOYTEC 8 3 4 Numere COMO iris 60 AA Bar OO E e ee II A Reel 60 8 10 end COMO dia 62 83 8 Dale COMO Sasi isan cada 67 8 58 Data EOF CONTON ais tacts e ie 67 8 3 9 Schedule Contro A A 68 8 210 Alarm List Control RE BR IR 71 8 0 Data Pointsec niae E a EE Eaa 72 8 61 atad Olt Proper S onenen e a O eas 73 8 7 M pp ne Tables ccs sides sec cad ii acid 76 SJal Mappins Table Properties see 76 5 9 ACHO OD ec ne 77 8 8 1 Action Properties Seas ea 21 SI GS aa 81 8 9 1 Collection Proper eS sisiane 81 8 9 2 AAA u 81 S10 Alarm AAA een S EEE 82 8 10 41 Alarm Generator Proper ieS a an a 83 810 2 Application HIN een 84 8 11 Data Point Connectors sicsisiiciiesinisecesssctececessstsseleececssedssesenssecedenscesssesdessdcasdecsnss 85 3 12 M thematicObjees u wa canis 86 8 12 1 Matlr Objeet
192. ly laid out to fit the current tick mark spacing and allow easier readout of the displayed data Set the final control size after enabling the grid and choose a size which yields a good looking result for the grid e Preserve Data When enabled the Control is instructed to store the recorded data in non volatile memory in order to preserve the data across a reboot or power failure Saving is done in regular intervals when enough data was collected or when the unit is shut down in a regular way and thus has a chance to save all unsaved data before shutdown not possible during a power failure e Auto save data The interval given here is the maximum time which may pass before recorded data is saved This can be used together with slowly moving trends where only a small amount of data is generated over time and thus the normal save operations which collect around 4kB of data before saving it will not be guarded very well against a sudden power failure With a data point selected the following options are available e Draw Minimum Enable recording and display of the minimum curve for the selected data point e Draw Average Enable recording and display of the average curve for the selected data point e Draw Maximum Enable recording and display of the maximum curve for the selected data point LOYTEC electronics GmbH L Vis User Manual 65 LOY TEC NOTE NOTE Use the preserve data option with care and avoid unnecessary savi
193. minal External switch inputs Two external switches push button or open close can be connected between terminals INO and GND as well as IN1 and GND on the connector labeled SWITCH The status of the switches is available on the device in two system registers Switch Input I and Switch Input 2 On the LVIS 3E100 device INO is also used to control the integrated Lamp Actuator object which is always present as part of the static interface of the device TCP IP connection In case a CEA709 unit is connected to an IP 852 channel or a BACnet unit 1s connected via BACnet IP connect the Ethernet cable to the connector labeled 100Base T The device also accepts 10Base T connections via this port CLEAR jumper To remove the currently stored project from the device set the jumper labeled CLEAR disconnect power and connect power again Wait until the unit has started and remove the jumper again Table 2 Terminals and Jumpers Version 3 1 LOYTEC electronics GmbH L Vis User Manual 30 LOYTEC 4 5 LEDs and Buttons All LEDs and buttons are accessible from the front and the bottom side of L Vis Please see the descriptions below for their functionality Status button Reset button Pressing the Status button sends out a service pin message on the IP 852 or the FT 10 LPT 10 channel CEA709 models or send out an I Am message BACnet models To remove the CEA709 network configuration data which was stored on the device when it was
194. mit Here is an example with four entries Po for o NORMAL 20 49 9999 Once a mapping is defined t can be stored to a file Save button and loaded Load button to define the mapping for other controls in subsequent projects This way an archive of frequently used mappings can be built for use in various projects To use the same mapping for other controls of the same project just copy and paste the mapping table object in the tree view The same mapping table can be used in both directions Translating incoming values to texts bitmaps or colors as well as looking up a value to send out when the user selects a given element from the mapping table via a dropdown list or a push button browses the table to find the next entry All texts bitmaps and colors used in a mapping table are included in the file when the mapping table is saved so that the mapping file is self contained and can be loaded and used on different PCs even when the source bitmap files may not be available To define the color for a single entry either select the entry from the list and click the color button to the right of the text input field or directly click in the area to the right of the text whose color you want to set in the color bar A color selection dialog will appear from which you may select the desired color LOYTEC electronics GmbH L Vis User Manual 77 LOYTEC NOTE To define a mapping table entry which should not modify the c
195. mple Figure 27 Turnaround binding for the time network variables Add a text control to the page and name it Hour Use the context menu of the text control to add a data point Select the new time stamp input network variable and select hour in the Element Create two more text controls one for the minutes and one for the seconds Assign the minutes and seconds Elements from the time stamp input data point to the controls On the mapping tab of one of the text controls create new entries for the numbers from 0 to 59 and add the text for the numbers e g one for 1 two for 2 Save this mapping table to a file button Save Go to the mapping tabs of the other text controls and load the stored mapping table Load the project to the L Vis device To show the correct text the update interval of the timer object has to be set to 1 second LOYTEC electronics GmbH L Vis User Manual Version 3 1 149 de ler Maus 1011 Lis Configuration Ele dt Model Piare Yes ep A amp Sa Page Pla Pet Eee finer Coated Ecco i Tex Wane ED fname Sule OL Lot For Het pee Fo LOYTEC Gane Common Propis app Cata Pod Color Lien Page Soren ehe Leit taith Toe lisage Ding Cies Contras 16 Aa el Soe IMA Figure 28 Text Watch project LOYTEC electronics GmbH L Vis User Manual 150 LOYTEC 15 Solutions This section describes solutions for some standard applications The solution project
196. ms should be received A CEA709 device normally delivers alarms through an output NV of type SNVT_ alarm 2 located in the node object of the device therefore the new input NV on the local device must be bound to the alarm output NV of the remote devices node object 9 8 E Mail Templates Version 3 1 To make use of the E Mail functions mail templates can be created in the folder called Mail Templates These are actually not data points but are connected to data points and are therefore managed in the same window For each different type of mail a template must be created and set up as required The template may then either be used to send mail when one or more trigger data points reach a certain value or the template may be triggered by an action object see the description of the action object in section 8 8 To create a new mail template select the folder called Mail Templates open the context menu in the data point list and select the item New E Mail Template A new dialog to set the properties of the new template is opened This dialog has three tabs which are used to set up the new mail template LOYTEC electronics GmbH L Vis User Manual 105 LOY TEC 9 8 1 Common E Mail Properties NOTE This tab is used to set the basic properties of the mail First enter a name for the new email template and the desired list of recipients Separate multiple recipient addresses by comma or semicolon The following types of recipient lists a
197. n room 9 4 Local Scheduler and Calendar To use scheduler and calendar functionality on the device the appropriate data objects need to be created first followed by a few additional configuration steps which are detailed below 9 4 1 Point Creation As the first step the required data points must be created Create the calendar point in the calendar folder and the required scheduler points in the scheduler folder as described earlier in this chapter 9 4 2 Calendar Point Configuration Version 3 1 Once the calendar point is created attach new calendar patterns as required to describe the individual day classes like holiday maintenance day and so on Do this by using the command Create Calendar Pattern from the context menu of the calendar point A new dialog appears where you can enter a name for the calendar pattern and edit the days which should belong to this day class When done close the dialog using the Create Pattern button Repeat this step to create all required patterns All patterns configured here will later be available on the local schedulers for use LOYTEC electronics GmbH L Vis User Manual 98 LOY TEC 9 4 3 Scheduler Point Configuration NOTE NOTE To configure the local scheduler points select the command Configure Schedule from the context menu of the scheduler point The same dialog which appears when a new scheduler is created is shown and allows to configure the scheduler Of course this ste
198. n the mapping table Mapping tables are discussed in detail in section 8 7 for now you can leave the table alone All the controls should now have one data point connected with the text control and the bitmap control having a data point and a mapping table The bitmap control needs some more work since we need to assign graphics to the individual values of the connected data point To do this select the mapping table object which was automatically created and attached to the bitmap control On the Mapping property page select one of the entries in the list for example the entry for the value 0 which maps to the text OFF Click on the button Select Bitmap and select a suitable graphic to show for this state A few simple graphics are installed together with the configuration software More icons and demo projects can be downloaded from the LOYTEC website search the L Vis download page for the Icon Library package or you may draw your own graphics as well Almost any bitmap format like BMP JPG GIF PNG and so on may be used Vector graphics cannot be imported directly Use the export function of your vector graphic software to generate a GIF BMP or JPG file in a suitable pixel size first Working with graphics is covered in section 13 12 of the manual Once you selected a bitmap file the bitmap control will resize itself automatically to fit the selected icon Repeat the process for the remaining states until all states have a bitmap
199. name is nviAlarm 2 Also you may assign this NV to one of the L Vis functional blocks as required Due to the static input NV which is required for a CEA709 alarm client point adding alarm clients will change the static interface of the device To keep the project reusable in different networks it is desirable to create the remote alarm data point manually on CEA709 devices and define the connection to the alarm server by the network binding only Instead of using data from a network scan a remote alarm data point can be created as follows e Select the data point folder named Alarm and use New Remote Alarm from the context menu in the data point list to bring up a dialog to create a new remote alarm point e Enter a name for the data point a name for the input NV which will be used to connect the alarm server of another device to this data point and select the desired functional block in which the NV should be located On BACnet devices the new data points can be used right away to exchange alarm information with the alarm server on the remote device Just connect the new alarm client data point to an alarm list control to view and acknowledge alarms reported by the associated alarm server On CEA709 devices there is one extra step to take before the new data point will be operational The new static input NV representing the alarm client on the local device need to be bound to the alarm output of the remote device from which alar
200. nd can act as a remote network interface providing access to the FT 10 channel to which the device is LOYTEC electronics GmbH L Vis User Manual 136 LOY TEC NOTE connected It also provides functionality to run the LPA software on this interface to monitor the FT 10 channel Using this feature will cause additional load on the device which should be considered at the time of project design If the project already requires a lot of CPU time to run it may not be feasible to use the same device as a remote network interface at the same time The current state of the RNI module is available in a system register called RMI State It may be used to make a running RNI connection visible on the display as a warning message or other element to alert the user 13 8 Local Data Point Capacity BACnet models are currently fixed to a maximum number of 512 local server objects In most cases the L Vis device operates as a client retrieving and controlling the value of server objects on other devices Therefore there are usually not many server objects required on the L Vis device itself The number of client connections to other devices is limited only by available system resources CEA709 models allow setting the capacity for local network variables including static and dynamic NVs excluding NVs which the firmware creates automatically in the Network Settings dialog which is accessible from the File menu of the main window The default sett
201. nd program the device with the required project as explained in the section about integrating a new device using static NVs and plug in mode e The device will be programmed the database will be updated and the device will be commissioned in your small network project e Decommission the device in your helper network close it and open the final target network in which the device should be replaced e Connect the device at its original location in the network and execute the standard procedure of your network management tool to replace a device In both cases make sure that the stored project which is programmed into the replacement device has the correct model number set This can be checked in the Network Settings dialog The number must match the last byte of the program ID of the device to be replaced If this is not the case and the model number is not adjusted before the download the replacement of the device may fail with an error stating that the new program interface does not match the previous program interface 10 2 3 Mixed Projects static and dynamic Version 3 1 These projects are the hardest to replace since it takes a two step process to complete the replacement First the new device needs to be loaded with the project to match the static interface of the original device then it may be commissioned in the network to get the LOYTEC electronics GmbH L Vis User Manual 112 LOY TEC dynamic NVs created and then t
202. nd so on A system parameter object is either a read only or a write only value depending on the direction of the data object e Register A register is a place to store data internally instead of communicating with other devices on a network Registers are used to internally transfer data between objects for example when a mathematic object calculates a value which should be displayed on a control the result of the calculation is stored to a register and the control reads the value from the register for display A register is therefore always represented by two data objects One to write a new value to the register and one by which the current value of the register can be read LOYTEC electronics GmbH L Vis User Manual 9 LOYTEC NOTE e Local Network Object A local network object refers for example to a static or dynamic network variable CEA709 models or a BACnet server object BACnet models which exists on the device Most of such objects are either write only output NV BACnet input objects or read only input NV BACnet output objects They are therefore represented by one data object with the appropriate direction One exception to this rule are BACnet value objects which may be read and written and which are therefore represented by two data objects just like registers e Remote Network Object A remote network object is a reference to some object existing on a remote device on the network Such a reference is called a clie
203. ne E Pinsel E Paget Contra 15 Aa al Sie IA Figure 20 SNVT_switch with a text control 14 1 2 Bitmap Control Version 3 1 Bitmap controls are typically used for information which has only a few states like heating on off light on off This example shows how to use a SNVT switch together with a bitmap control It also fixes the value part of the SNVT_ switch network variable to 100 and toggles only the state part e Adda bitmap control to the page e Add data points to the control To do this select Add Data Point from the context menu of the control Add a input data point for nviSwitch state and output data points for nvoSwitch state and nvoSwitch value A default mapping between the state input values and the displayed text is automatically added to the control e For the input data point nviSwitch state set the System Startup flag on the Data Point configuration tab e For the nvoSwitch value network variable go to the Data Point configuration tab configure the Default Value to 100 and set the Constant Value flag Set the NV Update Flags value to Focus Loss LOYTEC electronics GmbH L Vis User Manual 143 LOYTEC For the nvoSwitch state network variable set the NV Update Flags value to Focus Loss Select the mapping item in the tree view and go to the Mapping tab In the value list select OFF Click on Select Bitmap and choose a bitmap which should be displayed when the switch is OFF After this select
204. nected to a text control the text part will be shown together with the color settings When the same mapping object is connected to a bitmap control the bitmap will be shown Number and bar controls use the color setting only 8 7 1 Mapping Table Properties NOTE NOTE Version 3 1 The properties of a mapping table are set on the Mapping property page The New Entry button on this page adds a new entry to the mapping table If you want to add a new entry but the New Entry button is grayed out you most likely have a control selected in the tree view which does not yet have a mapping table object attached to it Go back to the tree view and add a mapping table object or use the Load button to load a mapping table from a file The value component of the new entry defines the lower limit for the input value to display the given text bitmap and or color Since multiple entries will be present in the table the entered values build up ranges which define the texts and bitmaps to display for every possible numeric value The valid range for each entry in the mapping table is defined to reach from the value of the entry itself up to but not including the value of the succeeding entry If this is the last entry it is used for all values up to infinite since there is no more entry to define an upper bound For practical reasons the first entry in the table always ignores the entered limit and is also used for any value lower than its own li
205. ng an existing network is another way to generate template points Depending on the type of device and the current operating mode of the configuration software there are different ways to scan the network e BACnet no connection to a device In this mode there is currently no way to scan the BACnet network To execute the scan a connection to a BACnet device must be established first e BACnet connected to a device via FTP The network can be scanned by the L Vis device which reports the results back to the configuration software To start the scan use the context menu of the BACnet Network Scan folder and select the menu item Scan BACnet Network e CEA709 no connection to a device In this mode network scanning is currently not possible Connect to a device first e CEA709 direct connection not LNS mode In this mode network scan is currently not possible because the scanner engine on the device can only be operated over a TCP IP link LOYTEC electronics GmbH L Vis User Manual 96 LOYTEC CEA709 connected to a device via FTP In this mode the device is able to execute a network scan and report the results back to the configuration software similar to the BACnet scan Since the device scans the physical network the results can only include information which is stored on the devices in the field not information which may be present in an LNS database like a device name functional block names or NV display names To
206. ng of unimportant data since these operations may take up a significant amount of system resources and adversely affect performance and life time of the device in case they are heavily over used in a project To save all unsaved trend data manually use the command Save All Trend Data from the command page of the setup menu or build your own save button in the project which can be implemented by writing the value 5 to the Command system register Even if the preserve data flag is set a trend control may still discard the stored data when it reboots This is the case when the controls properties were changed such that the new configuration does not match the stored data anymore for example because new data points were added to the control or data points were removed changing the type and amount of data recorded Recorded trend data is also removed from the device if there is no control matching the recorded data which is determined by the UID of the control That is if you remove a trend control from the project and reboot the device the data which belonged to the removed control will be deleted from the system 8 5 6 1 Trend Data Access Version 3 1 For every trend control which stores the recorded data in non volatile memory a file is created on the file system of the device which holds the data in binary form This file is not intended to be used by the end user Instead the recorded data is made available in CSV file format in order
207. nnected to a control the control becomes an input control meaning the user may select the control and input new data which is then assigned to all connected output data points unless they are marked as Constant Value If only input data points are connected the control is not selectable and will only display the most recent value received from any of the connected input data points Some controls like trend log controls may not be used to input new data but may still be selectable to navigate through the recorded data e Access Level If a control is an input control it will only enter input mode if the current access level of the user is equal to or greater than the level defined for the control on the Common Properties page option Access Level for Data Input To change the access level a suitable PIN code must be written to the system register called Pin Code Enter for normal login or the new access level can be set directly by writing the register Access Level LOYTEC electronics GmbH L Vis User Manual 36 LOY TEC NOTE NOTE Version 3 1 It is valid to connect input and output data points to the same control at the same time This is often done when the control should display the current state of a network value for example the current light level and also allow the user to modify this value using the current value as the starting point The control will ignore any values coming in from the input data points while
208. non standard interface In this case check the last byte of the program ID It is the program ID model number and it must match the model number of the project which you consider for download e Once a project with matching model number was identified this will most likely be compatible as far as the static interface is concerned To double check you may go through the list of static NVs defined in the project and compare it with the NVs that should be available on the device according to the devices definition in the network If the static interface seems to match the replace procedure may be started e During the replace procedure if the selected project causes data points to be reported during project load which cannot be assigned to any of the existing dynamic NVs then this project assumes a different set of dynamic NVs and is most likely not the right version of the project Repeat the process with other projects The only time when such reports are to be expected is during the first download in a two stage replace procedure as required for mixed projects static and dynamic NVs 10 4 2 Change Network Configuration There are a few cases where the network definition of the device is changed to match the current configuration of the device Such changes are normally handled by the network management program but may be supported by functions of the configuration software as well While changing the device configuration requires one o
209. nt mapping on BACnet devices since it maps the value of the existing data object on the L Vis device to a data point on a different device Depending on the direction of data flow the mapping can be either read poll or COV or write There may be more client mappings for the same remote object for example to a remote BACnet value object which can be read and written and is therefore represented by two client mappings On CEA709 devices external network objects are called external NVs since they are references to NVs located on other devices There is currently only one reference per external NV A remote network object is usually only constructed from data retrieved by a network scan and will only work as long as the referenced object does not change its configuration From the data which is retrieved by a network scan it is possible to create a local network object from the client mapping The user will decide if a client mapping or a local network object is the better solution which depends on the network technology and the type of installation For CEA709 it is usually better to create local network objects and use a network management tool to define the bindings to other devices in the network for BACnet it may be more convenient to use client mappings instead 9 2 User Interface Since the data objects are not part of the object tree shown in the main window there is a separate window to manage these objects The same window is also use
210. nt models For a single color background select the desired color on the Color property page All other properties of a page object are set on the Menu Page property page On this page the following settings are available e View Timeout If this timeout is not zero and there is no user input for the specified amount of time the system automatically switches to the next page provided there is more than one page connected to the same menu item After the last page was shown the procedure is restarted from the first page e Page Access This defines the minimum access level required to view the page if it is marked as locked protected see below e Locked Page If this flag is set the page may only be displayed if the current access level is equal to or higher than the level specified for this page see above If the access level is not sufficient a suitable PIN code must be entered e Invisible Page Allows hiding the page on the device which means that it will not be accessible for the user until this flag is removed However the controls on a hidden page work as usual for example a trend control placed on such a page will still be recording trend data A hidden page may also be used as the target of a show page action so that the page may only be visited through this action and not directly via the menu e Default Page Mark this page as the default page of the device The default page is displayed after a configurable amoun
211. ntrol will always be the width of the widest icon and the height of the tallest icon You can test the look of your bitmap control by selecting the individual states in the mapping table and watch the LCD preview The state which is selected when you write the project to the device will become the default state of the control 2 3 8 Write the Project to the L Vis device NOTE Version 3 1 We are now ready to write the project to the L Vis device but first the project should be saved in a file on the PC Although it is possible to read the project back from the device it should not be considered a 100 safe place for the project to be since the device may erase the project in case it finds a severe error which would otherwise prevent it from booting up again If the erase jumper at the back of the device is set or the Remove Configuration command is selected from the File menu the project in the device may be lost as well so it is a good idea to have a backup copy ready on the PC To save the project select Save as from the File menu and enter a project name To write the project to the L Vis device press the button with the red down arrow in the toolbar or select Write Project to the Device from the Connections menu and confirm the dialog If you created static NVs a warning message will appear stating that the static interface of the device will change and that the software will need to adjust the definition of the device in
212. nual 15 LOY TEC 2 3 Quick Start Tutorial CEA709 This tutorial describes the steps to create a first demo project and load the project into a CEA709 device like the LVIS 3E100 The tutorial assumes that the configuration software is already installed and the LNS plug in is registered as described in the prior section For the LNS specific part of this tutorial the LonMaker 3 1 network management tool is used Other network management tools which are based on LNS 3 or above which support dynamic network variables and the LNS Plug in Interface can be used as well for this tutorial e g Newron s NL220 SPEGA s Alex 3 Professional 2 3 1 Add the device to the network The first step 1s to integrate the device into an existing network Depending on the device type and the type of network used this step is either done on the device or on the PC using network management software In any case the device first needs to be physically connected to the network and a suitable power supply 2 3 1 1 CEA709 with LNS Create the L Vis device in the LNS database Add the L Vis device to your LNS network project Since the L Vis configuration plug in already creates the device templates the device configuration can be read from the device template Choose the device template which matches the network interface mode FT 10 or IP 10L of your device The Node ID of the device can be entered manually Optionally a service pin message can be sent
213. o If your condition 1s inside or outside range you need to enter both values to define the range for the condition above max only the maximum value is required and for the condition below min only the minimum value needs to be filled in Define the Action that should be taken The basic choice here is to have the alarm generator SET the alarm when the condition is satisfied and also CLEAR the alarm when the condition is no longer satisfied However you may want to only SET the alarm when the condition is met and not clear it again because you may require the user to manually clear the alarm later In this case use the set on alarm enter action which will only set the alarm but will never clear it To actually clear the alarm you can either use other means to update the alarm output variable or you can have a separate input on your alarm generator and define a rule for this input which will eventually clear the alarm using the clear on alarm leave action As the last step define the desired output either for both conditions set and clear or for only one of them The required input fields will be active while the other ones will be grayed out Note that the description field may currently only contain ASCII characters LOYTEC electronics GmbH L Vis User Manual 84 LOY TEC The above procedure needs to be repeated for all connected input data points 8 10 2 Application Hints While it is pretty straight fo
214. ock Drag a input or output network variable shape from the LonMaker network management tool shape sheet and drop it on the function block The dialog in Figure 7 is shown Choose A Network Yariable X Please select the network variable z you wish this shape to OK represent Selecting multiple network variables will result in shapes being automatically dropped Remove prefix fram NW names e Remove array subscripts from MY names Figure 7 Choose network variable dialog Select Create NV and in the displayed dialog Figure 8 enter the name for the new network variable and click on Browse Version 3 1 LOYTEC electronics GmbH L Vis User Manual 121 LOY TEC Create Network ariable 1 x Wewe M Mame nviSwwitch K Cancel How many Help if Member sUndetined Source Mi Browse Direction Poll Attribute of newe MW e Clear C Same as source Ww C Set C Opposite of source NY Figure 8 Create network variable dialog In the dialog Figure 9 select the network variable on the node to which the new dynamic network variable will be connected afterwards The dynamic network variable will get some attributes of the selected variable like the SNVT type assigned Click on OK to confirm your choice Echelon LonMaker q x select Object Subsystem 1 Actuator LAS Network Interface Zen L wIS Sensor El Closed Loop Sensor un ny i01 Valuer noli value 3 8 Node
215. ocumentation for color mapping theft protection Updates after review 02 08 Added new sections about data point management and standard solutions as well as some smaller improvements and corrections 2006 10 13 Rewrote a large part of the manual to make it more useful hopefully based on user feedback The example and solution sections remain unchanged for now The new BACnet model LVIS ME200 is now also covered by this manual Ba Updated for Release 3 1 0 also including documentation which is relevant to the 3 0 x series of firmware which was not included in the last version Version 3 1 LOYTEC electronics GmbH
216. of any register or network object Even if all registers and network objects were to be deleted the control would not be affected The data object itself is nor represented as an object in the tree view because it is not part of the user interface and is not bound to any of the other objects in the tree Data objects exist on the device independent from the user interface and are identified by a unique ID They are created and managed in a separate window the Data Point Management and Selection dialog In some cases they are created automatically like the data objects representing the system parameters or data objects representing dynamic network variables which may be present on a CEA709 device Data objects may be thought of as the source or sink of a data flow where every object has a defined direction either source or sink e g data coming in or data going out For internally created registers two such data objects are created one to write data to the register and one to fetch the current register value Input and output network objects are represented by a single data object with the appropriate direction BACnet value objects and other objects which may be read and written are represented by two data objects one for read access and one for write access Structured network objects as available on CEA709 devices are represented by individual data objects for each of the structure elements in addition to the object representing the en
217. of several repetition operators The preceding item is optional and matched at most once The preceding item will be matched zero or more times The preceding item will be matched one or more times n The preceding item is matched exactly n times n The preceding item is matched n or more times n m The preceding item is matched at least n times but not more than m times Two regular expressions may be concatenated the resulting regular expression matches any string formed by concatenating two substrings that respectively match the concatenated sub expressions Two regular expressions may be joined by the infix operator the resulting regular expression matches any string matching either sub expression Repetition takes precedence over concatenation which in turn takes precedence over alternation A whole sub expression may be enclosed in parentheses to override these precedence rules The back reference n where n is a single digit matches the substring previously matched by the n sub expression enclosed in 16 3 2 Ambiguity Version 3 1 If a regular expression could match two different parts of the input string it will match the one which begins earliest If both begin in the same place but match different lengths or match the same length in different ways life gets messier as follows In general the possibilities in a list of branches are considered in left to right order the possibilities for
218. oint individually Removing data points may be necessary to be able to remove the referenced data object since the data object keeps a reference count and cannot be deleted as long as it is referenced by a data point in the project 7 2 6 Expand Fold Tree The commands to expand and fold the object tree are available on menu items pages and folders They can be used to expand or fold the object tree below the selected object 7 3 Main Menus 7 4 Tool Bar Many of the items in the main windows menus do not require additional explanation as they are commonly found in modern PC software Also a short description of every menu item can be seen n the bottom left of the main window when moving the mouse over the menu item in question All items specific to this configuration software are referenced from the individual sections in this manual which explain the items function that is the function 1s explained and the menu item via which the function may be accessed is pointed out not the other way around The tool bar in the main window contains some of the commands which are used more often Pointing the mouse on one of the too bar buttons will open a small bubble help with a short description of the buttons function All functions of the tool bar are also accessible from the main menu Similar to the menu items the individual buttons will be mentioned in the sections where their functionality is described 7 5 Workflow Version 3 1
219. oints including a simple 1f else statement Input voltage 24V AC or DC The LVIS 3E100 model CEA 709 also provides Up to 512 network var ables and alias var ables Up to 512 address table entries FT 10 LPT 10 or Ethernet IP852 operation selectable via a jumper on the device When in FT 10 mode the device can still be reached via its Ethernet port for fast project download A lamp actuator object to control the backlight from the network This object was used to control the internal relay on the older LVIS 3ECTB devices A switch object to provide a standard switch and dimmer function as available on other CEA709 devices The switch input for this object is the INO connector Both INO and IN inputs are also available as system registers for internal use A temperature sensor object which outputs the current value of the external temperature sensor optional A real time keeper object which outputs the current system time 8 L Vis functional blocks which can be used to place static or dynamic NVs related to the data points used in the project Network scanning to find other device on the network and help in creating the required network variables on L Vis The LVIS ME200 model BACnet provides Up to 512 server objects accepting COV subscriptions Available object types are analog binary and multi state each as either input output or value object BACnet IP or MSTP connectivity jumper selectable Networ
220. om the context menu of the imported point e Register This is a folder for internal registers created by the user To add a new register select th s folder and then use the New button or the context menu to add a new register object As explained before a new register will automatically yield two new data objects read and write e System This is the folder in which the available system data objects are located All these objects are automatically created and cannot be removed or modified in any way They can only be selected to create a new data point for the object tree e Calendar This folder is used to hold a locally available calendar object with its calendar patterns definitions of day classes like holiday maintenance day and so on Current devices allow one local calendar object To create it select the folder and use the New button or the context menu e Scheduler This folder is used for local scheduler objects Each of these objects will connect to a local scheduler on the device and will be configurable through this data object that is the data objects transfers scheduler configuration data between the actual scheduler present on the device and the user interface e Alarm This folder is used for local alarm servers On CEA709 devices only one alarm server may be created which basically represents the node object of the device which is used to manage system alarms On BACnet devices an arbitrary number of alarm server o
221. on is repeated for a fixed number of times which is entered in the field to the right of the dropdown box This 1s the total number of times the action is executed at most including the first time After each execution a delay which is configured next to the repeat count 1s inserted If there 1s an additional condition for example a value condition and the condition becomes false any further execution of the action is stopped immediately e Controlled by value The action is executed as long as the value of the parent object meets the requirements specified in the Options section Note that if this condition is false at the time the action trigger fires the action will not be executed As long as the conditions are met the action will be repeated again with a configurable delay between each execution as above If the delay is set to 0 the action will be executed exactly once like the condition execute once but only of the value condition applies e While touched The action is executed as long as the parent object is being touched As above observe that this condition must be satisfied at the time the action trigger fires or the action will not be executed In practice this means that the condition while touched is useful only in conjunction with the action trigger on touch or n rare cases on value update but not together with on selection because selection of a control implies release of the touch screen
222. onnect the Data Points 222222222222222ssssssnnnnnnnnnnnnnnnnnnnnnnnnnnnn 23 24 7 Wrtethe Project tothe L V18 GeviC a i n 24 DAG VA A a A 24 3 Mechanical Installation siii caian dino aliada coa coRe Sansa 25 3 1 Dimensions and Moun scsssosccassssccvisscsssssvesessccarsaesedsaneesessseseaneversdsvassesuswtetes 25 32 IheltProtechon unse sau iui 26 4 Electrical Installation sen 28 4 1 Connection disgra cur iiaeia vee eaii 28 4 2 Electrical Ch ratteris esn an ua an 28 4 3 Touch Panel Cleaning Instructions ssssssssssssssssnnssssssssssnnnnnnsssnnnnnnnnnnsssnnnns 28 44 Terminals and Jumpers iia a a a a 29 4 3 LEEDS and Buttons ai en 30 LOYTEC electronics GmbH L Vis User Manual Version 3 1 A LOYTEC gt Interface Conheuration ia 32 SL AA erna E E E 32 5 2 Configuring the IP 852 interface 32 6 Uperatino L Visits lacada 34 6L SU A thusacaucishiaeriadbecasseaharence 34 A E 34 0 2 E ADEI O aa a ee 35 02 Data Input 35 62 8 SCIROCCO MEL ia 37 6 3 Setup Meni A a a T 40 03 1 CUstOmy Seti MEM rd 42 7 CoOnt2uration SO Ware Ask 43 TA Mam WINDOW A ren 43 12 A O 43 72 AAA ido 44 1 22 En able Disable Access Control asien a 44 Ta CUE COPY Pas teste lege 44 7242 AM EXPO Mrs ateos 44 ae Mana se Data Pong ea 45 1 2 0 Expand ON A CCG asia 47 1 3 Ma Menus iaa vansssduascaside uesaseencsesecdsvessssevasnssl s 47 1 4 LOO Bar Rau 47 1 5 WOrkKf
223. oot menu as well as its colors and other properties such as the width of the menu or its scroll bar using the property pages to the right of the tree view make sure the root menu object is selected which should be the case right after you started the software The menu object is described in detail in section 8 2 First add a menu item to the root menu To do this right click on the root menu object in the tree view and select Add Item from the context menu A new menu item is created and connected to the menu object The new menu item is automatically selected so that you may browse the property pages and see what you want to change The name of the item object can be changed in the Name box of the General property page This changes the name of the object in the object tree and has no effect on the appearance of the menu item on the device To change the text of the item itself go to the Common Properties page and change the contents of the Text box The display in the preview window changes as you type so you can immediately see the results You may want to change the font to the 12x16 ROM Fixed R font so you get a larger item which is easier to select on the touch screen The menu item object is described in detail in section 8 3 Repeat the steps above to add another menu item and call it Setup Again change the Text of the item to read something like Setup and change the font to make the item a comfortable size This item wil
224. opy commands to perform the desired operations If this operation is restricted the time table menu will not open 6 2 1 12 Edit Exception Days Version 3 1 To change the days on which a certain exception schedule is active select the exception day in the left column and touch the headline of the time table to open a dropdown menu From this menu select the edit command to open a new window in which the definition of the active days may be modified The window has two columns to show the type of entry and the data The following entry types are possible e Single Date This type of entry defines a single date pattern consisting of a day month and year specification Each of them may be specified or left unset wildcard so that this type of entry is suitable to define anything from a single day of a specific year all parts given up to every day of every month in every year all parts set to wildcard e Date Range This type of entry defines a number of successive days given a start date and an end date Depending on the use of wildcards for the year or the month the range may apply only once once a year or every month e Week and Day This type of entry defines a specific day in a specific week of a specific month for example every second Friday in April Again using wildcards for the individual components allows specifying more than one specific day of the year for example the first Monday of every month or any Monday in April
225. orded data like text number bitmap or date controls The individual data records are created in the folder called Data Fields which 1s part of every data log control To add a new log record select Add Record from the context menu of the Data Fields folder Then add the visible elements required to compose your data record to the new folder and attach the data point you want to record As you lay out the visible elements to build a nice looking data record the control adjusts its line height to match the area required by your data record You will notice that each added data record already comes with a trigger object which has similar properties than a math object Connect the data points you want to monitor to LOYTEC electronics GmbH L Vis User Manual 68 LOY TEC NOTE determine when to store this data record and enter the required formula on the property page of the trigger object Then select a trigger mode from the available choices If the trigger mode is set to any value update there is no additional condition to enter in the formula field since the trigger will fire as soon as any of the connected input data points receives an update To limit the frequency at which the trigger may fire and cause data to be recorded a minimum time between two trigger events can be specified together with a maximum burst rate which is the maximum number of events that are allowed in fast succession after a long idle period It is possible
226. out Immediately protects all locked pages The user has to enter the PIN code again to unlock the locked pages e Back one page Show the page from which the current page was reached similar to the back button in a web browser The system keeps a record of the last 256 pages visited via the show page action and picks the most recent of them to navigate back one step e Send E Mail Send out the mail referenced by the action To select the mail template to use press the Select button next to the link line and select the desired mail template Please refer to section 9 8 for a detailed description of mail templates The action update data points can also be used to increment or decrement the value of a register or of a network output feedback input pair which is required to implement up down buttons to dim light or modify a temperature set point To do this connect the register read point or the network feedback point as well as the register write point or network output point to the action Use the value translation of the read point to modify the incoming value as required add or subtract a fixed value When the action is executed the modified input value will be assigned back to the output value Since both refer to the same local register or remote actor the value of the register or the remote actor will be changed Once the action type is selected choose the desired trigger mode from the dropdown list next to the action
227. p can also be done directly when the point is created First attach the data points which should be controlled by the scheduler Switch to the tab Scheduled Datapoints and use the Attach Datapoints button to select and attach one or more data points to the scheduler There may be limits in how many and which data points may be attached to a scheduler For example on a BACnet scheduler only data points with compatible data types may be attached to the same scheduler object On a CEA709 scheduler only data points representing an entire NV may be connected but not individual elements of a structured NV For each of the attached data points one or more lines appear in the list below the attach button If the attached point is a structure there will be one line fir each element of the Structure Enter a Description text in the second column of each line This text will be shown when the user changes a value set on the device later on Add new value presets by entering a name and pressing the Create button next to the input field For each new preset a new column will appear in the list In this column enter the desired value for each of the attached points which will be set when this value template is scheduled The user may later edit the values for each preset on the device but cannot add new value presets unless there 1s only one line one value in the list If there are multiple output values which belong together they can be grouped
228. pe number Note that lines for standard object types can be omitted lvis units csv This is the unit text sheet The file contains a line for each engineering unit enumerator value Note that lines for standard units can be omitted NOTE First download the project to the device wait for the device to restart and then access the EDE files The device will create files matching the loaded configuration when it starts Version 3 1 LOYTEC electronics GmbH L Vis User Manual 130 LOY TEC 13 Advanced Topics 13 1 Project Settings Using the command Project Settings from the File menu a number of advanced options can be controlled which apply to the entire project The dialog is organized in a number of sections which are explained below 13 1 1 Page Protection In this area all options related to access control can be configured The following data can be set e Setup PIN Codes This button opens a new dialog where the 16 available access levels can be configured For each level aname and a PIN code can be entered except for level 0 the lowest level which cannot be protected e Next download sets PIN codes If this checkbox is selected the next project download will reset the PIN codes stored on the device with the codes entered in this project Otherwise the PIN codes of the devices are not modified PIN codes can be changed on the device during runtime by writing new PIN codes to the PIN code Set system registers e Lock
229. perature Sensor object according to the LONMARK Functional Profile 1040 It sends out the current temperature in the nvoHVACTemp network variable of type SNVT temp p The object is configured over the configuration properties e SCPTmaxSendTime e SCPTminDeltaTemp e SCPTminSendTime e SCPToffsetTemp The configuration properties are described in detail in the LONMARK Functional Profile specification On the L Vis device the temperature sensor object reads the current temperature value from an external temperature sensor connected to the input terminals labeled TEMP on the device The same temperature is also available via a system register which is the preferred way to read the temperature if it is used directly on the L Vis device LOYTEC electronics GmbH L Vis User Manual 129 LOYTEC 12 Special Functions BACnet 12 1 EDE Export of BACnet Objects The current BACnet server object configuration of BACnet L Vis models LVIS ME200 is accessible as a set of CSV files following the EDE format convention They can be downloaded via FTP from the directory data ede on the L Vis device The files are lvis csv This is the main EDE sheet with the list of BACnet objects lvis states csv This is the state text sheet For each state text reference in the main sheet a line contains the state texts for this multi state object lvis types csv This is the object types text sheet The file contains a line for each object ty
230. persistent data will be saved before the device restarts e About Show the about page default title page e Exit Exit the setup menu and return to the main menu The CEA709 models provide the following additional pages e CEA709 On this page the device can be given a CEA709 address domain subnet node and can be set online This is useful to connect to the device in standalone mode before the device is actually commissioned in a network for example because the project needs to be downloaded first to define the static interface of the device and there is no TCP IP connectivity available e CEA852 RNI On this page the IP 852 parameters or RNI parameters depending on the mode of operation can be specified Supported parameters are the escrow and aggregation timeout the IP 852 port number the MD5 key and the NAT support mode Please refer to the documentation of your configuration server for more information about these parameters The defaults should normally be OK unless your channel uses MD5 encryption in which case you need to enter the MD5 key and activate it by selecting Enable with new key gt from the dropdown list after the key was entered The key is displayed as 8 groups of 4 digit hex values which is a common representation of MDS key values The order to read the key is from left to right and top to bottom It is not possible to enter the configuration server or time server on the L Vis device Instead the dev
231. points which should be monitored Each of the connected input data points will show up on the alarm generators property page where the monitoring rules can be defined It is sometimes useful to connect the same input data point twice or more times to the same Version 3 1 alarm generator when the desired alarm conditions are too complex to cover in one rule for example different rules for alarm set and alarm clear or multiple non overlapping value ranges which should trigger an alarm In this case assign different names to the connected data points on the General property page so that you may distinguish between them later Once the required input data points are connected the alarm generator needs one output data point to which the result should be written The desired output data point must be connected before the alarm generator can be configured because the type of data point determines the configuration options The following data point types may be used as outputs for the alarm generator e Alarm Server On CEA709 devices a local alarm server data point may be connected to deliver the alarm to remote alarm clients and display the alarm on an alarm list control The alarm server keeps record of all pending alarms delivers them to any connected clients and manages acknowledgement of alarms e Scalar Value Any data point representing a single scalar value for example a register In this case the alarm generator uses the connected d
232. posed of zero or more directives ordinary characters not which are copied unchanged to the output stream and conversion specifications each of which results in fetching zero or more subsequent arguments Each conversion specification is introduced by the character and ends with a conversion specifier In between there may be in this order zero or more flags an optional minimum field width an optional precision and an optional length modifier For some numeric conversions a radix character decimal point or thousands grouping character is used The actual character used depends on the implementation The L Vis device uses as radix character and does not have a grouping character The character is followed by zero or more of the following flags The value should be converted to an alternate form For o conversions the first character of the output string is made zero by prefixing a 0 if it was not zero already For x and X conversions a nonzero result has the string Ox or OX for X conversions prepended to it For a A e E f F g and G conversions the result will always contain a decimal point even if no digits follow it normally a decimal point appears in the results of those conversions only if a digit follows For g and G conversions trailing zeros are not removed from the result as they would otherwise be For other conversions the result is undefined 0 The value should be
233. quired access level for the control as set on the Common property page The following operations can be protected individually e Change time of existing events This operation allows the user to change the time hour and minute at which a value presets is scheduled The entry in the time table must already be there since this operation only allows modifying the time for existing entries e Change preset selection This operation allows the user to change the value preset which is scheduled at a certain time The entry in the time table must already exist the user may select a different preset from the list of available presets for example change the air condition from economy to comfort e Edit values of existing presets This operation allows changing the physical values which are assigned to existing value presets The user may for example change the light level assigned to the bright setting from 80 to 100 percent e Define new presets This operation allows the user to define new value presets if the scheduler unit controls only one value e Add and remove entries This operation allows the user to add and remove entries in the time table Also bound to this operation are the related operations to clear entire days copy them to other days as well as enabling and disabling individual days e Change effective period This operation allows the user to change the effective period of the schedule thereby enabling and disabling not onl
234. r If a value dependent trigger mode or condition is used at least one input data point will usually be connected to the control to deliver new values e Data Point Connector If the action is connected to a data point connector any triggers or conditions which require user input are not available A data point connector can only feed a current value to the action therefore the only trigger modes which will actually trigger are value update and state From the conditions the while touched condition cannot be used since it would require the parent to feed user input information To avoid confusing situations it is required that only one object at a time is processing user input Therefore if an action is connected to a control and the action uses a trigger mode which depends on user input for example touch release or selection the normal input behavior of the control will be disabled since the user input is forwarded to the connected action The action type and trigger mode are now selected The next step is to select the condition under which the action may be executed The following conditions are available from a dropdown list directly below the action type e Execute once When the action trigger fires the action is executed once without further conditions This is one of the most widely used settings LOYTEC electronics GmbH L Vis User Manual 80 LOYTEC NOTE Version 3 1 e Repeat action As above but the acti
235. r is usually only a little brighter than the background of the control the text appears grayed out Selecting a day for display is not restricted by access level settings 6 2 1 3 Set Exception Day Priority If the day is an exception day a number is displayed next to the day name This number defines the priority of the exception schedule relative to other exception schedules which may become active on the same day To set the priority touch the number and enter the desired value on the keypad This operation may be restricted by access level in which case the control will not react to a touch of the priority field 6 2 1 4 Change Time of Events Version 3 1 To change the time at which a certain value is scheduled touch the hour or minute number in the time table and enter the desired value The hour is entered in 24 hour format 0 23 or LOYTEC electronics GmbH L Vis User Manual 38 LOY TEC NOTE can be used to enter hour and minute n one operation HHMM For example touching the hour and entering 1254 will set the time to 12 54 Entries in the time table are always displayed in chronological order If this order changes as a result of modifying the time of an entry the entry will immediately move to its new position in the time table to maintain the correct order of events This operation may be restricted by access level in which case the control will not react to a touch of the hour or minute fields 6 2 1 5 Select V
236. rame oe uld be ted inside the wall or cabinet door For la nt and cabinet door mount a Ale pra 180 x 150 x 57mm Ea uld be made Display Mounting Box 7 0 inches 180mm iam Nos a 5 75 inches 1 50mm 53 inches Figure 1 Hole dimensions for wall mount and cabin door mount Version 3 1 LOYTEC electronics GmbH L Vis User Manual 26 LOYTEC For wall mount the frame should be mounted flush with the wall surface for cabin door mount the frame can be attached to the cabin door with 4x M4 screws Countersunk screws are preferred The front panel has four recesses to burry the countersunk screw heads The L Vis device slides right into the frame and the spring action of 8 springs holds the unit in place 7 0 inches 180mm 95 inches Cut out depth to support 25mm wire clearance 2 5 inches 63mm 3 inches r 7mm 5 75 inches 150mm Wall Cut Out Hole 8 25 inches 210mm ge 4 inches 4 10 mm 4 6 inches 6 5 inches 5 7 inches 117mm 165mm 145mm 3 5inches 89mm 75 inches 6 75 inches 171 mm Front Display Panel Figure 2 Display dimensions of L Vis 3 2 Theft Protection To protect the L Vis device the device can be connected to the wall mount frame with the supplied chain as shown in Figure 3 Version 3 1 LOYTEC electronics GmbH L Vis User Manual 27 LOYTEC pp 1 nn u _ Figure 3 Connecting L Vis to the wall mount frame Version 3 1 LOYTEC electronics GmbH L Vis User Manual 28 LOY T
237. re provided e To The mail is directly addressed to these persons e Cc A carbon copy goes to the addresses listed here e Bcc A blind carbon copy is sent to the recipients in this list Recipients on this list will not be shown in the mails sent to other recipients Other properties to fill in are the desired subject of the mail and a rate limit given in the maximum number of times this mail may be sent within a 24 hour period and the maximum number of times the mail may be sent in short succession In the top right area of the tab you may attach data points to this mail Every time this mail is sent the current value of all attached data points 1s fetched and may be added to the mail text Use the following procedure to embed the current value of a data point in an email e Press the Add button to select the desired data point e The selected point will be added to the list of data sources e Select the data point from the source list and make sure the dropdown box below the list is set to Selected Data Source Value e Set the cursor to the position in the mail text at which the value of the data point should be inserted and press the Paste to Text button to add the required placeholder string to the mail text Alternatively the placeholder string may be entered manually while typing the email text The placeholder format is variable where variable is vl v2 v3 and so on The variable name assigned to a specific data source
238. reassign data points to different data sources use the reassign or duplicate and reassign operations explained below 7 2 5 3 Select Data Source This operation s available if all selected entries reference the same data source It allows using the data point manager window to select a replacement source which must be of compatible type same type and direction as the original source 7 2 5 4 Reassign Data Point NOTE This operation allows reassigning a batch of entries to a new data source based on the currently assigned data source Use the naming rules to construct the desired name of the new data source from the name of the currently assigned data source This is most useful to remap all data points referencing data from one room to similar data of another room where the data source name contains the room number for easy remapping only the room number from the original name must be replaced by the number of the new room to construct the name of the new data source In contrast to the duplicate and reassign operation this operation only attempts to reassign the data points to other existing and compatible data sources New sources will not be created on the fly Instead the reassign operation fails if no compatible data source can be found using the new name 7 2 5 5 Duplicate and Reassign This operation is similar to the normal reassign operation only that the new name is not used to search for an existin
239. red This can be used to limit the frequency at which an action may fire If the delay is set to O it will be turned off This also causes any kind of repeated execution to be skipped so the action is executed only once per trigger event Below the Execute Action part of the property page is the Options section In this section any additional information which may be required by action types action triggers or conditions can be set here Options which are settable are automatically activated others are grayed out The following options are available LOYTEC electronics GmbH L Vis User Manual 81 LOYTEC e Value Used by the trigger value update and the condition controlled by value If both are used together they use the same settings differing value settings for the trigger and the execute condition would not make any sense since the condition must match at the time the trigger fires e Sound buzzer Used by the action type sound buzzer to set the frequency and the duration of the tone Useful values for the frequency range from about 500 up to 8000 The most intense sound can be archived at around 4000 Hertz The duration is normally a value between 100 and 3000ms 0 1s to 3s Note that the repeat delay should be larger than the tone duration since the repeat delay starts to run immediately after the action was triggered not when it completed e Link This is not an input field but a display of the destination page for a s
240. rmally not wanted in subsequent project downloads the configuration software will normally ask the user if the scheduler and calendar objects should be initialized with the configuration data from the project or not The behavior may be changed in the Project Settings Dialog between ask always download and never download In any case the configuration may be downloaded and also uploaded at any time from the Connection menu 9 4 5 System Resources NOTE Version 3 1 To actually implement the scheduler functionality there are network technology dependant software modules required on the device The scheduler and calendar data points created here will be connected to these modules and serve as the link to exchange configuration data between the user and the actual scheduler unit It is important to understand that the scheduler data points used in the project are not actually the scheduler units but only serve as a link to exchange configuration information and thus control the actual scheduler which may be located on a completely different device The device containing the actual scheduler may even be a third party device which is compliant to the standards for scheduling defined for the respective network technology In case of local scheduler objects the required scheduler units are either automatically instantiated BACnet devices automatically create the required server objects they need to operate the scheduler or need to be defined b
241. rmine the device model and firmware Load or design the project similar to the above procedures Open the Network Settings dialog and set the Program ID Model Number to the desired value This will be the last byte of the resulting program ID of the device Make sure there are no other devices n the same network using the same model number but a different set of static network variables Also zero is reserved for a device without static NVs so the valid range is 1 to 254 If required activate the CEA709 1 A restricted mode LOYTEC electronics GmbH L Vis User Manual 109 LOY TEC e Download the project to the device A warning message will appear notifying the user that this operation will now change the static interface of the device and that the configuration software will not be able to automatically upgrade an existing device in a network database since it is run in standalone mode Since the device will be integrated for the first time this is OK e The device can now be integrated into the network This is usually done using an XIF file or if available an upload from device method in which the network management reads the static interface directly from the device and thus requires no XIF file If an XIF file is required generate one using the Export XIF function from the Tools menu and use it to integrate and commission your device e If the network management tool does support plug ins and the newly created
242. rom the File menu and enter the desired model number for your device e Select Transceiver Since no device is connected the configuration software cannot automatically determine the transceiver used Therefore a dialog will appear and ask for the transceiver type which will be used by the device When the project for which this XIF file was created is later actually downloaded into a device make sure to use the same model number as you entered before the XIF was exported If the device already contains a project using the same model number but the static interface of this project does not match the new project the configuration software will automatically change the model number and the result would no longer match your XIF file In this case remove the incompatible project first and then download the new project In cases where the project is designed online while connected to a device all required data can be determined automatically To make sure that the model number in the XIF file matches the model number which is automatically selected during project download first download the finalized project to your device and then export the XIF file 11 3 CEA709 1 A Operation The CEA709 models normally support the CEA709 1 B standard which means that the device accepts the extended network management commands used to configure the extra resources available on such devices for example up to 512 address table entries on L Vis However
243. rward to configure a simple alarm generator to output an alarm when for example a temperature reaches a certain maximum value the alarm generator can be used for more complex applications as well Two of the most often used applications are described in more detail in the next sections 8 10 2 1 Alarm Condition with Hysteresis Consider you want to issue an alarm when a temperature rises above T1 but the alarm should not be cleared unless the temperature falls below T2 which would be less than T1 Similar to a thermal protection which once it activates turns off the device and does not turn it back on until the device significantly cooled down to avoid constant ON OFF cycles Such an application can be done by connecting the temperature data point two times To distinguish between them append SET to the name of the first data point and CLEAR to the name of the second data point on the General property page On the Alarm Generator property page configure the SET data point to cause the Action set on alarm enter enter T1 as the maximum value of the Data Point Value Range and select Above Max for the alarm condition For the Alarm Output choose the desired output value for the Set Action The Clear Action should be grayed out since the rule specifies no alarm clear action Now there are two options available to configure the CLEAR data point Here is the first one Like on the SET data point keep the Alarm Condition at Above Ma
244. s than this intermediate values will not be sent out until the minimum send time has passed at which time the current most recent value is sent out e MaxSend If this amount of time has passed without any updates usually because the value did not change in the meantime then the current value will be sent out This is commonly described as a heartbeat function used to allow the receiver to detect if the sender is still alive and just not sending new information because there is none or if the sender has died and therefore no new data is received e PollTime Can work as a simple poll interval or as a receive timeout Usually used as receive timeout for bound NVs on CEA709 devices and otherwise used as poll cycle time If used as a receive timeout it specifies the amount of time after which the device sends out a poll request if no value update was received As a poll cycle it specifies the amount of time after which a periodic poll request should be sent out independent of any updates which might have been received in the mean time LOYTEC electronics GmbH L Vis User Manual 76 LOY TEC 8 7 Mapping Table The mapping table is used to map values of numeric data points to text strings bitmaps and or colors The mapping table object controls the display of text controls bitmap controls numeric controls and bar controls and may be added to these objects A mapping table can include text bitmaps and colors at the same time If con
245. s a chain of following updates which does not end because one of the following updates again triggers the original update For example register A is used as input for a mathematical object which writes its result to register B while at the same time the value of register B is copied into register A using a data point connector The configuration software is able to check for such loops when they are caused entirely by internal objects In such a case the project cannot be downloaded into the device and a warning message appears showing the objects which cause the infinite update loop However the configuration software cannot check loops which are closed via the network because it does not have enough information to do this For example if a data point connector is used to connect a switch input SI to a switch output SO this in itself does not constitute a loop at all But when the update of SO on the network is sent to a lamp actuator and the lamp actuators feedback output is connected to the switch input SI the result may be an infinite update loop between the L Vis device and the lamp actuator depending on how the actuator behaves Once the L Vis sends out an update on SO it will be received by the lamp actuator This may cause the actuator to send out an update on the feedback output which will be received by L Vis on the input SI which in turn will be copied by the data point connector to the output SO and so on The result can have adv
246. s and their meaning can be found in the LONMARK description of the SNVT alarm 2 network variable type Alarm Output Input Data Point rl emp O06 Alarm Set Type AL_ALM_CONDITION Alarm Clear Type AL_NO_CONDITION Priority Level PR_LEVEL_O Y Description 22 chars max Data Point Value Range q O Action f Set and Clear Alarm Set on Alarm Enter Clear on Alarm Leave Alarm Condition Value is Os Inside Range C Outside Range Above Max Below Min Freeze Alarm Figure 25 Alarm Generator configuration tab LOYTEC electronics GmbH L Vis User Manual 147 LOY TEC To display the alarm output we will draw a bitmap which shows an ice symbol in alarm state To do this add a bitmap control to the page Enter a label for the bitmap in the Text box of the Common Properties tab Select Add Data Point on the context menu of the bitmap control Add a Reg Read data point as described above and use the same name FreezeAlarm for the Name in the Register Properties field Set the Type to alarm 2 164 and select alarm type for the Element On the Mapping tab of the data point select the AL ALM CONDITION Click on Select Bitmap and choose a bitmap which is displayed when the alarm condition is met Load the project into the L Vis device Ha E Pod Freee e fe Ka 0 Lia Ctr Lage Test Conta Kar Meu Lump Buber j Cees Lores 1 Fresse A Preec
247. s attached to it a menu item object may have page objects and sub menu objects attached and a page object contains the elements to display and enter data these elements are called controls in this manual You may navigate through this tree and select an object from it or drag and drop objects to move them around in the hierarchy for example grab a control from one page and drop it on another page An empty project contains only a root menu and a folder object where global objects can be placed which are not directly related to the user interface for example alarm generators Property View On the top right of the main window is a property view which shows a number of property pages where you can adjust the properties of the currently selected object The number and kind of property pages changes according to the selected object but some of the more basic property pages are available all the time Feel free to browse through the available pages and see what you can adjust there LCD Preview To the lower right of the main window is the preview of the project as seen on the LCD when the project is downloaded This is not a functional simulation of the L Vis device but a layout guide and preview of individual menus and pages The preview changes according to the currently selected object Since the configuration software comes with a library of the layout code used in the various firmware versions of the device the preview is always accurate to
248. s can be found in the Projects directory of the L Vis configuration software install directory 15 1 Implementing Menus By default the user can navigate in a project using the main menu submenus and push and drag operations With the help of bitmap controls text controls and action objects t s also possible to implement alternative ways to navigate inside an L Vis project The project Menu _examplel lcp shows different solutions 15 1 1 Tab Menus To switch between multiple pages a tab menu can be implemented using bitmap controls text controls and action objects see Figure 29 d Menu_exsmples gt Li Confiquration Fla dt Model Free es Help Je A kang Fl Subseries ISLAS OMKET Uiga Gera Common Papais banging Cate Port Coie terna Paga Tea Seren Caidir tt gt mamo 4 Toe Wage Dibra Fest Ces User bee 1 ips Lien Lasd Unk o daba Feine I Asse A Pape 17 contre 110 Cie 1 Saree SL Figure 29 Page navigation using Tabs Each page contains four bitmap controls There are two types of bitmaps one for the active page Figure 30 and one for the inactive page Figure 31 Version 3 1 LOYTEC electronics GmbH L Vis User Manual 151 LOYTEC i Figure 30 Active page bitmap Figure 31 Inactive page bitmap The bitmaps are aligned to form a row of tabs On each tab a text control 1s placed with identifies the page and the page links in the example it is called Page 1
249. s document Similar to text controls the color of the number the background and the selection frame can be set on the Color property page The Numeric Control property page provides access to the specialized properties of numeric controls like the allowed value range and a wizard to generate a suitable format string for your control if you don t want to enter it yourself on the common properties page The allowed Value Range is only enforced when the control is an input control and the user inputs new data Values received from input data points are always displayed even if they are outside the allowed value range that is the range is an input value range only The Input Resolution and Acceleration settings are only used by the older LVIS 3ECTB model which has a jog dial instead of a touch screen The settings define the amount which is added or subtracted with each turn of the jog dial and how the dial speed increases this amount The check box Convert Data Point Value to Integer needs to be checked when you want to use an integer format specifier n the format string like x or d If the format string wizard is used to generate the format string this check box is also controlled by the wizard as required The check box Hexadecimal Input Keypad can be used together with a x format to provide a hexadecimal input keypad matching the way the value is displayed It would be confusing to enter a decimal value and then see it conv
250. s explained above the configuration software does not modify the pixel data in such a case This is because images like this are most likely already dithered to fit the 256 colors in which they were saved To convert such a picture to VGA colors the already dithered image would have to be run through the dithering algorithm again which is likely to result in very poor quality images In such a case it is better to get the original versions of the pictures true color or vector graphics and create suitable VGA graphics from this source If this data is not available the existing pictures may also be converted to true color images before use which will then trigger dithering to the VGA color palette Version 3 1 The following image file types are supported e Bitmaps bmp e Icons ico e Joint Photographic Experts Group JPEG jpg e Tagged Image File Format TIFF tif e Portable Network Graphics PNG png e Graphics Interchange Format GIF gif The file open dialog automatically shows all supported graphic files it finds n the directory Unsupported files are hidden True color or high color images will automatically be dithered and converted to the fixed VGA color palette used by L Vis as explained above 8 bit indexed color files like GIF will be loaded as is without any changes LOYTEC electronics GmbH L Vis User Manual 141 LOY TEC 14 Examples This section shows how to use the different controls in
251. se setup menu may be provided or a subset of the complete setup menu such as specific commands from the command page or the setup of date and time only The example projects that are installed together with the configuration software include projects for the standard setup menu of the CEA709 and BACnet models These projects should provide a good starting point for a customized setup menu LOYTEC electronics GmbH L Vis User Manual 43 LOYTEC 7 Configuration Software 7 1 Main Window The main window of the configuration software is shown in Figure 4 It is divided up into 3 main areas as explained in section 2 3 3 of the tutorial a Supermarket enn LW Configuration File Edt Model Firmers Gormection Format Took View Help JOM FRE Bow see E EE 2 BSA ROSE Sawu OFFLINE E El Root Menu Lights EH Lights Pubic HHE aches EHE Shopping area Eal Wale ine Read mA Control e Alig Yae Read e SAlicherals_ Wire General Common Propesties Mapping Data Port Color Walaa Traralaticn Setting Jorr gt ha Pina Data Paia Update Flags i f He Update Custom Translation i os I Free les OPi fo mih sf 1 ae eee ern l er System Startup Value Changes Oriy T No Ives Updales Be Map inakata Defi Lights heads Read de SWLightvalue_Wrhe RY Toon i Layout EHE Parking ke Edit Wale u PLL ighivakss_ Head SAM Control PllighiVaue Read PLLighrvaha write Bb Icon EE Mapping El a update dst spears
252. since the standard requires devices which were once configured using extended network management commands to no longer accept any of the older commands such a device would no longer be usable together with older management software which does not provide support for the extended command set To guarantee that the device will be usable together with older tools the Network Settings dialog which is accessible from the File menu has a checkbox to enable a so called CEA709 1 A restricted mode In this mode the device will not accept any of the extended commands and react according to the old standard This also means that the device is limited to 15 address table entries 11 4 Dynamic Network Variables Some of the installation scenarios for CEA709 L Vis devices make use of dynamic network variables This section gives a short description of how dynamic network variables are created in different network management tools 11 4 1 LonMaker Network Management Tool Version 3 1 To create a dynamic network variable create a functional block e g L Vis1 for the device as shown in Figure 6 LOYTEC electronics GmbH L Vis User Manual 120 LOYTEC unsere gt belch Lon ieber gt Laisi dba l E AEE E pe GR pm pomt yee Jok fupe Lohia timc be Type aa EF H oly m FU Ejea di gt E D Bansh rianar n n B BBF A 0 7 8 om gt 0 Closed Loop Sensor L VIS 1 Closed Loop Actuato La a Figure 6 Create a function bl
253. sing a d b Y H M S z The time zone or name or abbreviation LOYTEC electronics GmbH L Vis User Manual 163 LOY TEC The date and time in date 1 format Y A literal character Some conversion specifiers can be modified by preceding them by the E or O modifier to indicate that an alternative format should be used If the alternative format or specification does not exist for the current locale the behavior will be as if the unmodified conversion specification were used SU The Single Unix Specification mentions Ec EC Ex EX Ry MEY 0d Oe 0H OI Om OM OS 0u 0U OV 0w OW Oy where the effect of the O modifier is to use alternative numeric symbols say roman numerals and that of the E modifier is to use a locale dependent alternative representation 16 3 Regular Expressions 16 3 1 Syntax Version 3 1 A regular expression s a pattern that describes a set of strings Regular expressions are constructed analogously to arithmetic expressions by using various operators to combine smaller expressions The fundamental building blocks are the regular expressions that match a single character Most characters including all letters and digits are regular expressions that match themselves Any meta character with special meaning may be quoted by preceding 1t with a backslash A bracket expression is a list of characters enclosed by and It matches any single character in that l
254. sion 3 1 the color scheme will be changed in the object if the object supports this particular color while all colors which are unset in the color scheme will remain unchanged This allows changing individual colors only for example you may change the background of all controls on a page without changing any of the other colors There are two modes of operation available right now e Apply to all sub objects This mode will apply the color scheme to all sub objects of the currently selected object This is used to control the color design of the whole project root menu selected or individual pages a page selected e Apply to all objects of this type This mode will search all objects of the same type as the currently selected object on the same hierarchy level for example if you select an item of a menu and use this mode you can change the colors of all items in THIS menu without affecting other menus If you select a text control on a page you can use this mode to change the color of all text controls on THIS page and so on LOYTEC electronics GmbH L Vis User Manual 53 LOY TEC 8 Object Description 8 1 Introduction NOTE Version 3 1 Every L Vis project is built using a number of different objects Each of the objects has a relatively simple function To build a complex project the simple objects are put together and organized in an object tree which is shown in the tree view of the configuration software Inter
255. sired end result 10 4 1 Change Device Configuration Version 3 1 In case the current definition of the device in the network represents the desired end result the configuration of the device should be set back to match the definition in the database This of course is only possible if a matching project is still available as a file on a PC Assuming that a suitable project file is available the device may be easily restored by following the appropriate procedure for a device replacement as outlined earlier in this document LOYTEC electronics GmbH L Vis User Manual 115 LOY TEC To determine if a project is suitable or not it is not necessary to execute the whole replacement procedure just to find out that the result still does not match the definition of the device in the database Instead check the following things upfront before starting the download e Run the configuration software standalone without connection to any L Vis device and load the project which 1s considered to match the current device in the network e Check the program ID of the device definition in the network e If the ID starts with 9000a9 then the interface matches a standard device without any static NVs In this case only consider projects which do not contain any static NV data points The loaded project must have a Program ID model number of 0 e If the program ID starts with 9000d7 then the device has static NVs created and therefore uses a
256. snapshot buffer will be cleared when the project or the configuration software is closed If a certain state of the project should be saved for later reference it must still be written to a file on the PC 13 4 Layout Tools NOTE To aid in the layout of controls on the page there are a few buttons located in the tool bar which become available when two or more controls are selected in the LCD preview To select more than one control at the same time select the first control press and hold the shift key and select additional controls It is important which of the controls you select first The control which was selected first will act as the reference for the layout functions as explained below Once the controls were selected execute the desired layout functions by pressing the buttons n the tool bar or using the commands from the Layout menu of the main window 13 4 1 Alignment Functions Version 3 1 The alignment functions will align the left right top or bottom edge or the horizontal or vertical center lines of all selected controls The reference will be the first selected control LOYTEC electronics GmbH L Vis User Manual 135 LOY TEC 13 4 2 Make Same Size These functions make all selected controls the same width or height as the first selected control This function is usually used together with controls of the same type 13 4 3 Space Evenly NOTE These functions require at least three controls to be selec
257. stack enter the value in the input field above the button Add Value and then press the button To add a function to the stack select the desired function from the dropdown list and press the Add Function button When a function 1s added to the stack it will first fetch as many values from the current stack as it needs input values then execute its operation and put the result back on the stack LOYTEC electronics GmbH L Vis User Manual 87 LOY TEC NOTE Even if you use the infix notation at the bottom to enter your formula the dropdown list of available functions will be useful to look up the names of functions you want to use and see how many arguments they accept 8 12 2 Application Hints NOTE A few functions end with a three dots in the argument list This means that they accept a variable number of arguments When used in the formula they will fetch all available values from the stack in RPN syntax and then calculate the result which will be put back on the stack and be the only value on the stack since all other values were used as input to the function This behavior causes some limits in how these functions may be used You are on the safe side if you use such a function only as the outermost function or in RPN as the last function on the stack for example sum vl v2 exp v3 1 If you have to use it as an argument to another function t may only be the first argument otherwise the formula cannot b
258. start the scan use the context menu of the scan folder and select Scan CEA 709 852 Network CEA709 connected to a device in Plug In mode In this mode scanning is done on the LNS database The devices do not need to be physically present The information gathered from this type of scan will usually include more information because there is more information about the devices available in the LNS database However finding a device through this type of scan does not necessarily mean that the device will actually be available on the physical network whereas the results from a direct network scan will reflect the network as currently seen by the L Vis device running the scan To start the scan use the context menu of the scan folder and select Scan LNS Database A new window will open which is used to conduct the network scan Depending on the type of scan the window will contain different controls and options to conduct the operation A few things to note are BACnet Scan As the first step the current list of devices should be updated using the button Refresh Device List After a while the list of available devices on the network will be shown in the device list Now one or more devices may be selected from this list and the objects available on the selected devices can be scanned by pressing the button Scan Objects This step may be repeated for all required devices For each device a new sub folder will be created and the objects found on
259. t of idle time and when the device is started e Login Page Mark this page as the login page of the device The login page is displayed when the user switches to a protected page for which the current access level is too low On the login page there should be at least one numeric input field to enter a PIN code write the value to the PIN Code Enter register It is useful to place other information on this page as well for example the current access level and the minimum access level required to view the protected page A button to execute the back one page action is also useful in case the user does not have the required PIN code and wants to go back to where he came from e About Page Mark this page as the about page of the device This page is shown when the user selects the About item in the setup menu or when the device switches to the default page after the idle timeout and there is no default page set LOYTEC electronics GmbH L Vis User Manual 58 LOY TEC 8 5 Controls All objects which can be displayed on a page are called controls This is because they are usually used to provide to user with an interface to control a data point value or trigger actions Controls are also used to display the current value of a data point and sometimes even display just static content to enhance the visual appearance of a page NOTE There are other objects which are used to control or process data point values and which are not documented in t
260. tate of a data point in addition to its value For example if an input NV has a receive timeout set and does not receive a value the point will go OFFLINE and the display will indicate that the value shown is no longer considered valid Note that using invalid values in a formula will automatically invalidate the result therefore it is possible to turn state tracking off for individual data points see the description of the data point object The checkbox here is a master switch to turn state tracking off for the entire project 13 1 4 Remote Access NOTE 13 1 5 Sound Version 3 1 The option Enable VNC Server may be checked to enable a built in VNC server on the device if supported by the firmware version 3 0 0 or newer To use it a TCP IP connection to the device must be possible since VNC is a TCP based protocol The remaining options are used to set the TCP port on which the VNC server should listen for incoming connections the maximum number of simultaneous connections that the server should accept and an optional password to protect access to the device A device with a firmware supporting VNC which has no project loaded will automatically enable a VNC server on port 5900 and accept one connection without password This can be used to simplify device installation If a fresh project is started the VNC option is turned off by default To connect to the VNC server install one of the available VNC clients on your PC or other de
261. tching groups if present are extracted and are used together with the name template given in the second input field to build the new name The new name will be composed of the text in the name template with all occurrences of NO replaced by the contents of the first matching group all 1 replaced by the contents of the second matching group and so on For example the regular expression nvi nvo _ 0 9 will match the original name nviRoomTemp_2 and assign the substrings nvi to NO RoomTemp to 1 and 2 to 2 so that the new name when using a template of 0 1 3 will become nviRoomTemp 3 Please refer to section 16 3 for a complete description of the regular expression syntax Below the naming rule settings is a preview window which shows a preview of the resulting names and the number of matches 1n real time LOYTEC electronics GmbH L Vis User Manual 46 LOY TEC 7 2 5 2 Rename Data Source NOTE This operation allows batch renaming of data sources the actual register NV or server object name All data sources which are mentioned in the selected entries will be considered for renaming If a particular source is actually renamed depends on the given naming rules as described in the previous section Renaming a data source does not reassign any references to that source that is all data point objects which referenced the original data source will reference the same renamed data source after this operation To actually
262. te suitable remote scheduler points in your project e Note that any existing calendar is automatically imported as well e Adjust the basic settings for the newly created points which are now available in the folder Remote Devices list the object name and description The object name will be used as the name for the scheduler as seen on the display later on LOYTEC electronics GmbH L Vis User Manual 103 LOY TEC NOTE e For BACnet also adjust the poll cycle which will be used to periodically fetch the current configuration in case the remote device does not support COV subscriptions e For CEA709 a static NV is created to receive information from the remote device about changes to the scheduler configuration so that the local device does not need to poll the remote device Set a name for this NV default is nviSchedLink lt number gt and assign it to a suitable function block Due to the static input NV which is required for a remote CEA709 scheduler point adding remote scheduler points will change the static interface of the device To keep the project reusable in different networks it is desirable to create the remote scheduler and calendar data point manually on CEA709 devices and define the connection to the scheduler server by the network binding of the link NVs only Instead of using data from a network scan the required data points can be created as follows e Select the data point folder named Calendar and use New R
263. technology copy from a BACnet project into a CEA709 project these references will be lost 7 6 Common Property Pages The individual property pages visible in the property view will change according to the currently selected object Most property pages are directly related to a certain type of object Version 3 1 LOYTEC electronics GmbH L Vis User Manual 49 LOY TEC 7 6 1 General NOTE NOTE and will be discussed together with the object itself Some pages are used to set common properties and remain visible all the time These common pages are explained below This is the page which should be open while creating new objects in the tree view As you create new objects give them a suitable name here to clearly identify them in the tree view The object name specified here has nothing to do with the appearance of the object on the device if it is a visible object at all The name on this page is just the name of the object in the object hierarchy The name should be chosen such that looking at the tree view is enough to understand what an object is used for The large area below the name field can be used freely to enter any description which might be needed for other people to understand what this object does why it is here how it works and so on This can be used to store the projects documentation together with the project improving reusability and maintainability in case the project is taken over by another person later
264. ted They modify the horizontal or vertical position of the selected controls such that all controls have the same amount of empty space between each other This function automatically determines the two controls which have the greatest distance from each other and spreads the remaining controls out between them such that each control remains as close to its original position as possible the overall order of the controls is not changed no matter in which sequence you selected the controls This function may cause the rightmost or bottommost control to move by a few pixels if the original distance between first and last control did not allow the other controls to be evenly distributed between them This may be the case because a control can only be placed at an integer pixel position which means that the calculated space between the controls can either be 4 or 5 pixels but not 4 5 pixels If the total amount of originally available space is not a multiple of the calculated best fitting distance the last control may need to be moved a little to accommodate for the rounding error 13 5 Find Similar Objects To make it easy to locate objects in the object tree which are similar to the currently selected object the function Find Next from the Edit menu or the keyboard shortcut F3 can be used Select the desired object and press F3 to skip forward to the next similar object An object is considered similar if it is of the same basic type menu men
265. ter 7 value lt eclounterWalus bf Gack Icom ae Show Main Menu E Setup Menu Global Objects Math Objets x a Counter Increment by 10 Decrement by 10 Comter 1 Merge Bils For Help press Fl Menus 1 Items 3 Pages 6 Controls 44 Datapoints 1 Size 134 4 Counter E Figure 41 Counter demo configuration The counter demo shows how to use a bar graph control to simulate the fill level of a container An empty container is formed by a bitmap control On top of the bitmap control a bar graph control is placed All relevant colors except the Bar Bitmap color are set transparent so that the bar graph forms the filling of the container Version 3 1 LOYTEC electronics GmbH L Vis User Manual 159 LOY TEC 16 Appendix A Format strings 16 1 Number format strings 16 1 1 Flags Version 3 1 The format string used in text controls and numeric controls is equivalent to the format strings used by the ANSI C printf function L Vis will always use the given format string to format exactly one argument which will be a string an integer or a double precision floating point number depending on the type of control and its configuration Therefore there should always be exactly one conversion specifier in an L Vis format string and its type needs to match the argument provided by the control For example it will not work to use a d specifier for a text control or a s specifier for a numeric control The format string is com
266. text received from the network In this case the configuration software does not now the size of the longest text at configuration time therefore the user needs to reserve a suitable size for the text manually Version 3 1 Below the screen coordinate section is an area where a bitmap can be loaded A number of graphic formats are supported for example BMP JPG PNG TIFF and others Not supported are any vector formats They need to be exported to a bitmap format first When a 256 color GIF or PNG image is loaded indexed color format the configuration software does not change the color indices of the loaded pixels that is the color palette of LOYTEC electronics GmbH L Vis User Manual 51 LOY TEC NOTE 7 6 3 Color NOTE Version 3 1 such an image should match the VGA palette If you are unsure or get false colors when loading such an image save the image in true color format and let the configuration software do the color conversion dithering as required Graphics import is discussed in detail in a later section Depending on the object type the image is used according to the following table Object Type Bitmap is used for Icon which is shown to the left of the menu item text Page background The loaded bitmap should match the screen resolution of 320x240 pixels Smaller background pictures are placed in the top left corner of the display For example a 320x20 bitmap would appear as a page header while an 80x2
267. the respective device template which will be automatically created for each device in the CEA709 Templates folder On these templates you can now configure a few settings like the desired data point name or the type of data point external or static NV These settings will be applied automatically when a point matching the template is used on the device When the templates are ready it is possible to use all data points from all scanned objects which match one of the available templates and have the default settings applied to the newly created points To do this select the command Use on device and apply all templates on the top level scan folder A remote network object refers to another device in the network which had a certain configuration at the time the scan data was collected If the configuration of the remote device changes later on the remote network object may stop working until the network is rescanned or the mapping to the remote device is changed manually to reflect the new configuration To avoid this situation and to keep a project reusable for different networks or different subsystems within the same network it is therefore desirable to create local network objects instead when using a CEA709 device and use the network binding to define the communication between the L Vis device and other devices This way the same project file may be used in different rooms communicating with different devices and not be specific to a certai
268. the controls should now have one data point connected with the text control and the bitmap control having a data point and a mapping table The bitmap control needs some more work since we need to assign graphics to the individual values of the connected data point To do this select the mapping table object which was automatically created and attached to the bitmap control On the Mapping property page select one of the entries in the list for example the entry for the value 1 which maps to the text SW NUL Click on the button Select Bitmap and select a suitable graphic to show for this state A few simple graphics are installed together with the configuration software More icons and demo projects can be downloaded from the LOYTEC website search the L Vis download page for the Icon Library package or you may draw your own graphics as well Almost any bitmap format like BMP JPG GIF PNG and so on may be used Vector graphics cannot be imported directly Use the export function of your vector graphic software to generate a GIF BMP or JPG file in a suitable pixel size first Working with graphics is covered in section 13 12 of the manual Once you selected a bitmap file the bitmap control will resize itself automatically to fit the selected icon Repeat the process for the remaining states until all states have a bitmap assigned to them Use different bitmaps so that you can distinguish between the individual states The size of the co
269. the database If you commissioned the device in the database already make sure to download the project in plug in mode otherwise it will be necessary to replace the device in the database new program ID and re commission See chapter 10 about standard procedures for CEA709 devices for detailed information about this topic Once the project file is written to the device the L Vis reboots and shows the tutorial project on the display If the NVs were creates statically in the project they should now be available on the device You can now bind the output NV and the input NV together In case of dynamic NVs this was already done earlier LOYTEC electronics GmbH L Vis User Manual 20 LOY TEC 2 3 9 Test the Project NOTE You should now be able to use the device to set the state and the value of the output switch NV and immediately see the results on the input NV since the two were bound together To change the state press the bitmap control A dropdown list with the tree icons you assigned to the tree states in the mapping table will appear Now select the desired icon to set the state Whenever an element is selected from a dropdown list of icons or texts the device will search the mapping table to find the value associated with the selected element This value will then be assigned to the output data points which are connected to the control The new state will be sent out and will be received immediately by the input NV The n
270. the device will be created in this sub folder CEA709 Scan Note that the device you are connected to must be commissioned in order to execute the scan If it does not yet have a valid network address a suitable address may be assigned in the area called Connected Scanner Device If you want to see a list of all reachable devices use the button Discover Devices alternatively start scanning for service pin messages by pressing the button Discover on Service Pin then go through all required devices and press the service button which will add the device to the list of available devices and stop the process using the Done button when finished Once the list of devices is ready use the button Scan Device to get a list of objects available on the device LNS Database Scan The current network will be selected from the database automatically Select the desired channel from the list of channels at the right to see a list of devices on that channel Now either scan all devices on the channel using the button Scan Channel or select individual devices from the list and use Scan Device for individual device scan When you are done with all the required devices close the scanner window and return to the data object management window The scan folder should now have a sub folder for each of the scanned devices containing objects representing the data points available on these devices Now the required mappings may be created from these points see next
271. the information collected by the network scan Once created a data object may be used to exchange data with other devices on the network store and load internal registers or access internal system parameters Every data object on L Vis has a distinct direction of data flow either read input or write output This is important because the data flow direction determines how a data point will be used by other objects in the tree For example a mathematic object will assign variable names vl v2 to all input data points and write the result of the calculation to all output data points For controls the direction of the attached data points determine if the control will be selectable to input new data or not The direction is defined from the point of view of the L Vis device in question referring to the network side not the application side Therefore an input data object will receive new data from the network and deliver this data to the application running on the L Vis device whereas an output data object will transmit new data from the L Vis out to other devices All data objects fall into one of the following categories e System Parameter This is a data object which cannot be created by the user It is provided by the device to modify certain internal system parameters like the time zone IP address BACnet instance number or others or read the current value of a system parameter like the current time CPU load free memory a
272. the pixel Should the layout or appearance of controls change with firmware versions the configuration software is able to track these changes and display the page exactly as it will appear on the device you are currently connected to LOYTEC electronics GmbH L Vis User Manual 17 LOY TEC NOTE You may Select move and resize your controls directly inside the LCD preview Also there are context menus available for each control which you can open by a right click on the control in the preview The cursor keys can be used to move controls one pixel at a time and to resize the control when the shift key is held down 2 3 4 Create Static NVs if no dynamic NVs available In case the network management tool used for the tutorial does not support dynamic creation of NVs on the device the NVs required for this tutorial must now be created manually using the data point manager window This window is accessible either from the tool bar the icon left to the connect button or from the main menu Edit gt Datapoints Please skip forward to section 9 3 2 for a description of how to create local network variables Following this description create one input NV and one output NV both of type SNVT_switch 2 3 5 Create Menu Structure and Pages NOTE The next step is to design a simple test page for this tutorial and use the two data points The empty project shows the root menu with no entries menu items You may change the name of the r
273. the user inputs data so that incoming data does not interfere with the users actions but resume displaying the incoming values when input mode is left If a control is selected it enters a special input mode in which all further touch actions are routed to and processed by the control Depending on the control type different data input methods are available e Numeric Keypad For number controls and bar graph controls a numeric keypad can be displayed when the input control 1s selected New values can then be entered on this keypad just like on a phone or a calculator e Touch and move For bar graph controls the bar may be directly moved to the desired position by touching the bar and moving it to the desired height While doing this the control can be instructed to send periodic updates to the connected output data points so the user gets immediate feedback useful for light control e Drop down selection For text controls and bitmap controls a drop down list is displayed when the input control is selected The user can select the desired item from the list e Push button mode For text controls and bitmap controls a push button mode can be activated This mode assigns a new value to a control whenever the control is selected The next value is determined by selecting the next or previous entry in the mapping table so the user may cycle through the available values e Actions There is an indirect way of assigning values to outp
274. time of the device are wrong If the SMTP server requires authentication set the option Enable user authentication and enter a user name and password Other types of authentication such as SSL TLS or POP before SMTP are currently not available and are usually only required by free mail service providers which have no other way of authenticating their users Standard ISP mail service usually authenticates the user just by IP address since the address was assigned by the ISP and therefore identifies the user as being a customer of the ISP Additional configuration data to fill out includes the sender address which is used n all mails originating from this device an optional reply to address the maximum number of delivery attempts per mail and the time between delivery attempts If the test receiver address is filled out the system command to send a test mail may be used to perform a basic check of the mail system All mail delivery attempts are logged to the system log Upload the system log through the configuration software and check for errors if a mail delivery attempt fails 13 2 Access Control Version 3 1 Access control is organized in 16 levels Pages and input controls can be assigned a minimum access level required to view the page or enter data on an input control Any access level higher than the specified minimum level automatically grants access to the protected object To reach a specific access level there are a num
275. tire network variable However most of the complex data objects which represent more than a single scalar value are not supported by most controls and cannot be attached to them The following exceptions to this rule apply for the current devices e SNVT_ switch Data output objects of this type may be directly connected to an alarm generator to control the entire switch e SNVT _ alarm2 As above data outputs of this type may be connected to an alarm generator to send out alarm messages e SNVT_ str_asc This and other string data types may be directly connected to a text control The string received via these objects will be displayed directly on the text control without a lookup in a mapping table If the data point is an output point the string selected from the mapping table is directly assigned to the data point without converting to a number first If the string contains non ASCII characters they are represented in the ISO 10646 character set and are transferred in UTF 8 encoded format This way it is possible to exchange strings in any language between two L Vis devices using a standard ASCII data type LOYTEC electronics GmbH L Vis User Manual 73 LOYTEC The data point object is the object created when Add Data Point is selected from the context menu of a control to assign a data point to it The reason why the assignment of data objects to controls is done via a separate object instead of directly connecting a physical data
276. to the stud labeled with the earth ground symbol Loosen the top nut and attach the earth ground wire to this location FT 10 LPT 10 connection The FT 10 or LP 10 network is connected to the terminal labeled LVIS 3E100 FT LPT The signal wires are connected to terminals A and B the shield if available is connected to terminal EARTH This EARTH terminal is connected to the main earth terminal BESSER connecuon When in MSTP mode the RS485 bus is connected to the terminal LVIS ME200 labeled MSTP External temp sensor Up to four external temperature sensors can be connected to the terminal labeled TEMP Compatible temperature sensors are available from LOYTEC under the part number L TEMP1 The temperature range of this electronic sensor specified as 55 to 125 C and the accuracy is 0 5 Celsius within the range from 10 to 85 C The resolution of the sensor is 0 0625 C The sensor device contains an integrated circuit which is connected via a digital interface to the main unit so that no further calibration is needed Multiple sensor devices are connected in parallel bus topology The measured temperature is available in four internal system registers Sensor I Temp to Sensor 4 Temp where the sensors are assigned to the registers by increasing serial numbers of the sensor hardware The terminal cannot be used for direct connection of passive NTC or PTC elements DO NOT CONNECT ANY DEVICES OTHER THAN L TEMP1 SENSORS to this ter
277. top right corner of the window Changing the values of a value preset will automatically affect all entries in all time tables which reference this value set If for example the fan speed assigned to the value preset NORMAL is changed from 60 to 75 all time table entries which set the output to NORMAL will use the new speed setting This operation may be restricted by access level in which case the edit command in the dropdown box is not selectable 6 2 1 8 Define new Presets NOTE Version 3 1 If the scheduler controls only a single value it is possible to create new value templates though the schedule control Touch the preset name on the time table entry for which you want a new preset and select the command value from the dropdown box Enter the desired value for the new preset using the keypad A new preset will be created for the given value and assigned to the entry on which the operation was executed Do not confuse this operation with the operation of changing the values assigned to an existing value preset This operation will actually create a new independent value preset and assign it to the selected time table entry not affecting any other entries Only if a preset for the requested value already exists the existing preset is used This operation may be restricted by access level in which case the value command in the dropdown box 1s not selectable LOYTEC electronics GmbH L Vis User Manual 39 LOY TEC 6 2 1 9 A
278. trols background The background of a text control may be 5 set to transparent using the check box next to the background color button Table 10 Color assignment for text controls If the text control is an input control t may be selected by a touch on the controls text field A dropdown list will appear containing all entries of the mapping table which is connected to the control From this list the user may select a new entry The value which is associated with this entry in the mapping table will then be assigned to all connected non constant output data points Instead of opening a dropdown list text controls may also be used as push buttons where each press of the button will change the value This push button mode can be enabled on the Text Bitmap property page which is explained below since it works the same for text and bitmap controls 8 5 2 Bitmap Control Bitmap controls are very similar to text controls only that they display graphic elements instead of text Otherwise the same behavior applies for input controls A static bitmap may be set on the Common Properties page which is shown when no mapping table is attached to the control or no value was set so that the control does not know which entry from the mapping table to choose Version 3 1 LOYTEC electronics GmbH L Vis User Manual 59 LOY TEC NOTE NOTE The bitmap control will automatically adjust and fix its size according to the loaded bitmaps If
279. ts and which points are controlled by which scheduler This information is part of the data point setup of the project similar to the definition of local and remote network objects LOYTEC electronics GmbH L Vis User Manual 99 LOY TEC NOTE It s always in effect when the project 1s downloaded and it will have an influence on the static interface of a CEA709 device The other part is the dates entered in calendar patterns and the actual schedule of each scheduler when the scheduler should output which value preset as well as the definition of the value presets themselves This information is usually changed during the runtime of the device that is it 1s considered dynamic data similar to the current value of a network variable or server object this data is n fact the current value of such objects Therefore this data is not reset with every project download since the user wants to keep the current values if possible Only if the scheduler setup itself changed the device will not be able to take over the current settings since they do no longer apply The scheduler and calendar configuration entered in the configuration dialogs is stored together with the project It can also be exported to XML format or imported from XML format Once the project itself was downloaded to the device for the first time the scheduler configuration should usually be downloaded as well to initialize the created objects with some data Since this is no
280. tton The tool tip of this button reads Update Data Points It will re scan the currently available dynamic NVs on the device and create the required data points for you If you added NVs while the plug in was open hit the update button to get the required data points added to your project automatically From the two items available in the data point list select the input data point and expand its items by a left click on the small plus sign left of the data point The expanded view will show two sub elements one for the state component of the NV and one for the value component A data point is selected by a double click or by selecting one or more points and clicking the OK button Use the above procedure to add the state part of the input NV to the text control the value of the input NV to the numeric control the state of the output NV to the bitmap control and the value of the output NV to the bar control LOYTEC electronics GmbH L Vis User Manual 19 LOY TEC NOTE NOTE When you add the state of the input NV to the text control another object called a mapping table will be created automatically and will be initialized to map the three known states of the switch state to standard state texts You may select this mapping table and change the texts as well as assign different colors to the individual texts in the mapping table Mapping tables are discussed in detail in section 8 7 for now you can leave the table alone All
281. u item page control data point and has the same name This allows for example to find all uses of a certain data point reference all back buttons all navigation bar folders and so on If the project uses meaningful names for the objects this function can be very convenient 13 6 Preview and Edit Mode Some designs want to hide the selection frame from the user when a control is selected on the device To archive this the selection frame color is set to the background color which in turn is set invisible in order to hide the selection frame This may cause problems when editing the project in the configuration software because the LCD preview normally shows the behavior of the device therefore such a selection frame is invisible in the editor as well To force the editor to ignore the device behavior and always draw a visible selection frame when a control is selected in the editor the button Edit or Preview Mode which is a toggle button can be pressed in the tool bar or the option Edit Mode may be checked in the Edit menu of the main window 13 7 Remote Network Interface Version 3 1 On newer hardware of the CEA709 model there is support for remote network interface functionality similar to that of a NIC IP The function is only available if the device is operated in FT 10 mode not IP 852 mode and only if the hardware can support it If active the device accepts connections from a PC on the TCP IP interface a
282. ubtraction of a fixed offset can be archived without using a separate math object For example an action which toggles a light switch may be implemented by assigning the inverted feedback input current switch state to the control output The inversion is done with DP 1 NV 1 The Details section shows details of the referenced data object like the name of the underlying network object the network object type units and other information Also shown is the unique ID of the referenced data object by which the object may be located in the data point management window for further inspection or modification In the Data Point Update Flags section the value update mode is specified There are three basic modes available together with some additional options LOYTEC electronics GmbH L Vis User Manual 74 LOY TEC Version 3 1 e No Update This means that this data point will not request the underlying data object to be updated even when the value on the control side changes Useful if this data point represents one element of a structured data object and updates to this element should not cause the complete object to be transmitted on the network e Focus Loss This update mode transmits the new value only when the input control returned focus and left input mode that is when the final value is known Intermediate values which are for example generated by moving the bar of a bar control around are not immediately transmitted e Immed
283. ue range for example 0 5 would be a good value For the Action select Set on Alarm Enter and select the desired output value for a cleared alarm from the dropdown list named Value for Alarm Set Action This is because we actually define an alarm condition when the button is pressed As a result of this alarm condition we then reset the real alarm The above examples may of course be combined to have automatic alarm clear when the temperature falls below T2 and manual clear via a button when the temperature is at least below TI 8 11 Data Point Connectors Version 3 1 Data Point Connector objects are used to receive a value from one or more input data points and copy the received value to all connected output data points or other objects which accept a value for example action objects A data point connector has no visible representation on the display and is therefore not related to any of the visible objects It can only be connected to a collection object as described earlier To create a new data point connector use the context menu of the collection object to which you want to add the data point connector Other than the general properties like object name and description there are no further properties to set Whenever a new value is received via one of the connected input data points the value will immediately be forwarded to all connected output data points This can be useful for example to connect an internal register to
284. unctional block of the remote device and the new static nviSchedLink NVs which were created for each remote scheduler point need to be bound to the respective nvoSchedLink variable located in the Scheduler functional block of the remote device The binding between the nvoSchedLink variable on the remote device to the nviSchedLink variable on the local device defines which of the scheduler data points on the local device connect to which scheduler unit on the remote device On BACnet devices the new data points can be used right away to exchange configuration data with the scheduler on the remote device Just connect the new scheduler data point to a schedule control to view and edit the configuration of the remote devices scheduler 9 7 Alarm Clients Version 3 1 Accessing alarm server objects on remote devices is done by creating remote alarm data points These points may either be created from data obtained by a network scan or can be LOYTEC electronics GmbH L Vis User Manual 104 LOY TEC NOTE created manually CEA709 only Here are the steps to create the required points from a network scan e Execute a network scan as described earlier in this document e From the points in the import folder select the alarm server points you are interested in and use the command Use on Device to create suitable alarm client points in your project e For CEA709 select the new alarm client point and adjust the name of the local NV default
285. urrent color set the color of the entry to Unset shown by the black cross To define a color gradient for a number of entries for example going from red to green set the color for all entries which should have a specific color and leave all others unset black cross Then hit the button to the right of the New Entry button This will recognize all entries with set colors as fixed and calculate gradients between them assigning suitable colors to all previously unset entries To set a range of entries back to unset to re run the gradient algorithm you can multi select the entries from the list and then reset their color back to unset all at the same time 8 8 Action Objects Action objects are used to execute various actions on special occasions As such they are most often assigned to controls to trigger an action when the user touches releases or selects a control In some cases they are assigned to data point connectors to watch incoming data point values and trigger an action when a certain value is received In any case the action objects need a parent object which is able to feed the required information to the connected action such that the action may monitor what s going on and trigger at the right moment Currently these objects are controls and data point connectors For every action object there are three basic things which need to be defined e Action What should be done when the action triggers e Trigger When s
286. using a network management tool will show up as usable data points in the project but the functional block in which they were created will be unknown since the device itself does not have this information only the management software would know 2 2 1 3 CEA709 FT 10 CEA852 Connections In this mode the communication channel is CEA709 via a LOYTEC NIC such as a NIC USB NIC PCI or NIC 852 The device must first be commissioned assigned a network address either by using the same network management tool as used for the other nodes in the network or by entering a suitable unused address in the CEA709 setup menu In the connection dialog of the configuration software a suitable unused subnet node address must be entered for the network interface card of the PC The address of the device may either be entered manually as well or can be detected automatically by either entering the unique node ID or by pressing the service pin button on the device Once the address is known the connection can be given a name and saved just like the TCP IP connections so that the procedure is only necessary when the address of the device changes Connecting via CEA709 is most suitable when the device is not connected to the IP network and a non LNS network management tool is used for integration ADVANTAGES e Works even when the device is not connected to an IP network thus no need to set up TCP IP settings for the device e Download is faster compar
287. ut data points using the Update Data Points action This is sometimes useful for example to store a current value in a register data point when the user selects or touches a control These actions are explained in more detail later on e Alarm Acknowledge The alarm list control may draw a push button next to an alarm entry if the alarm is to be acknowledged Pressing the button will send the acknowledgement to the alarm server and change the color of the button Once the server received the acknowledgment the button or the entire alarm entry may disappear from the list e Schedule Configuration Due to the complex nature of schedule configuration data the schedule control implements a specialized input method which is explained in detail in section 6 2 1 The control decides when to leave input mode This is also called loosing the Input Focus since the control returns input processing back to the page which is currently shown Upon input focus loss the control usually sends out the final value and stores it in non volatile memory so that it is retained across a power outage or reboot The special persistent flag does not need to be set for these data points to retain their value The control forces persistent data storage automatically Controls usually return the focus when you touch an area outside of the control or when you leave the device idle for a specified amount of time Some controls like the keypad have OK and Esc buttons for
288. ut is cleared by causing an alarm condition 8 10 2 2 Alarm Clear via Data Point Version 3 1 Similar to the first example but instead of defining a temperature T2 below which the alarm will clear automatically a manual input should be used to clear the alarm Of course the two examples may be combined to have both automatic clearance below a safe temperature T2 plus manual clearance as long as the temperature 1s at least below T1 First we need to connect the input data point via which the alarm should be clearable This may be the state component of a switch a Boolean value a register or any other scalar LOYTEC electronics GmbH L Vis User Manual 85 LOY TEC NOTE value We will assume an internal register for this example which we assume will be set by the user pressing a button on the display We assume that pressing the button will set the register from 0 to 1 and releasing the button will set it back to 0 again The first part is the same as in the previous example The temperature variable is connected to the alarm generator and configured to cause an alarm when the temperature rises above T1 To clear this alarm we configure the connected register data point as follows Set the Alarm Condition to Above Max and enter a time delay of for example 3s This will require the user to press and hold the button for 3 seconds before the alarm will be cleared Enter a value between 0 and 1 for the maximum of the data point val
289. v d mod v m max vl min v1 avg vl log v log2 v log10 v exp v exp2 v exp10 v sart v pow v exp round v floor v ceil v sum v1 and b1 b2 or b1 b2 xor b1 b2 not b It v1 v2 le v1 v2 eq vl v2 ge vl1 v2 gt v1 v2 if b vt vf encode b1 sin v1 cos v1 tan v1 sinh v1 cosh v1 tanh v1 asin v1 acos vl atan v1 asinh v1 Version 3 1 LOYTEC Return Value vl v2 vl v2 vl v2 v d Returns the remainder of dividing v by m where v and m should be integer values Fractional values will be rounded to the nearest integer automatically Returns the maximum of all values on the value stack Returns the minimum of all values on the value stack Returns the arithmetic mean value of all values on the stack Returns the natural logarithm of v Returns the base 2 logarithm of v Returns the base 10 logarithm of v Returns the value of e the base of natural logarithms raised to the power of v Returns the value of 2 raised to the power of v Returns the value of 10 raised to the power of v Returns the non negative square root of v Returns the value of v raised to the power of exp Round v to the nearest integer Round v down to the nearest integer Round v up to the nearest integer Returns the sum of all values on the stack logical AND of the Boolean values b1 and b2 b1 amp amp b2 logical OR of the Boolean values b1 and b2 b1 b2 logical exclusive OR
290. vice VNC clients are available for PDA and even some cell phones and connect to the device You can then remotely access the LCD display of your device and use the mouse to operate the touch screen If the connection fails the most common reasons are e The maximum number of connections is reached e There are other clients connected and the new connection requests exclusive access Check the settings of your client and disable exclusive access n this case e There is one other client already connected and holds an exclusive connection If more than one user is connected to the same device everyone will see the same display just like VNC used on a PC The display of L Vis currently uses a VGA color map 256 colors It is therefore most efficient to transfer the color map to the client and then only transmit the color index for each pixel one byte per pixel If the VNC client supports this mode color map mode the VNC server on the L Vis device will tell the client that this is the preferred display mode to optimize speed and bandwidth usage However many clients only support true color modes where either two or more bytes per pixel need to be transferred or the color resolution will be reduced A client which supports color maps is RealVNC This section controls the sounds produced when touching the display and entering values The frequency of a low pitch and a high pitch sound may be entered and the sound output can be turned on
291. w data on the display A BACnet input object is therefore represented by an output data object whereas a BACnet output object is represented by a data input object To create a new server object and the required data object s to represent it select the folder named Server Objects and use the New button or the context menu to add a new object A dialog will open requesting the required information to create the new server object The following data may be entered e Datapoint Name This is the name of the data object representing the BACnet server object You may leave this empty in which case the server object name will be used e Object Name The name of the server object to be created This is the name which will be seen by other devices on the network LOYTEC electronics GmbH L Vis User Manual 95 LOY TEC e Object Type Select the required object type here Keep in mind that input and output here are according to BACnet naming rules for objects as explained above e Engineering Units Optionally specify the engineering units for your server object This will be available to other devices on the network as a property of your server object e Description As above optionally specify a description which will be available as a property of your server object for other devices or system integrators to read e Device Type Optional property for your object as above Once all the required information has been filled
292. where the static interface of a device needs to be upgraded manually and the network management tool has difficulties to take over the existing bindings during the upgrade In this case export the bindings remove them then do the manual upgrade and as the last step restore the bindings from the file 11 2 XIF Export Version 3 1 When the selected model is an CEA709 model and the current project uses at least one static network variable the menu item Export XIF becomes available in the Tools menu This can be used to create an XIF file for the current project for later device integration This is normally used when the network management software cannot run the configuration software in plug in mode and the device must therefore be integrated manually after it was programmed outside the network management with the configuration software running in standalone mode To generate an XIF that matches the actual device there are two options LOYTEC electronics GmbH L Vis User Manual 119 LOY TEC 11 2 1 Offline NOTE 11 2 2 Online A project may be designed completely offline without any connection to a physical device The target device type and firmware version are selected from the menu In this scenario the following extra steps are necessary e Select Model Number Since the project is never downloaded to a device the model number is not set automatically Before exporting the XIF file open the Network Settings Dialog f
293. will be created as necessary Not all types of data sources can be created automatically This is especially true for complex data sources such as alarm servers or local scheduler data points These references must be resolved manually after the copy was inserted If the copied object uses custom fonts and the object is pasted into another project these fonts may or may not be available depending on the setup of the destination project The software will search all loaded fonts in the destination project to find the required fonts based on the font size type and family as displayed in the font dropdown list If a suitable font is found it will be used automatically If the required font is not loaded the software will try to load and use the font from the copied object If this fails for example because the additional font would exceed the capacity of loadable fonts an alternative font from the destination project must be assigned by the user 7 2 4 XML Export Import Version 3 1 Using the Export to XML command objects in the tree view may be exported to an XML file The exported object will include all child objects but there will be no information about loaded user fonts or data objects included in the XML output so that importing the XML file into a different project may lead to unresolved references to fonts or data objects if the project configuration of the destination project differs from the source project LOYTEC electroni
294. would during normal operation of the device Once the touch is detected the cross moves to the next corner The procedure repeats until all four corners were measured Following the measurements is a verification pass A white filled circle appears at the same locations as the cross Again touch inside the circle to let the device verify the data from the measurement pass If the data s OK the screen lights up green if verification fails the screen lights up red The last position for verification is a circle in the middle of the screen which must be touched as well for the calibration process to complete If the verification pass was successful the new calibration data is stored in non volatile memory so that it is retained across a power cycle or reboot If you are unsure about the viewing angle at which the device will be used it is best to calibrate for a direct front view at a right angle to the display surface This is the most likely position and will also provide enough margin for error in all possible directions For normal control sizes the small errors introduced by differing viewing angles are not noticeable 6 2 Data Input Version 3 1 As shown in the tutorial L Vis uses configurable control elements to display and input data Whether a control is selectable for data input depends on the data points connected to it as well as on the current access level of the user e Data Points If at least one output data point is co
295. x but enter T2 as the maximum instead of T1 For the Action select Clear on Alarm Leave and select the desired output value from the dropdown list at the right This time the Value for Alarm Clear box will be active while the others will be grayed out This method is the correct way of doing it but it may be counter intuitive Many people choose Below Min for the alarm condition because they want something to happen when the temperature falls below T2 However the condition specified here is always the Alarm Condition It defines the conditions under which the alarm is considered to be SET It does not define when something will happen This is done using the Action setting The alarm condition in this example is still above a certain temperature and action will be taken when this alarm condition is CLEARED e g the device has cooled down enough Now if this seems unreasonable here is an alternative approach You may configure the CLEAR data point using the alarm condition Below Min and enter T2 as the minimum value of the Data Point Value Range Since you now defined below T2 as the alarm condition you need to take action when the alarm is SET so the action must be Set on Alarm Enter Now select the desired output value from the Value for Alarm Set Action dropdown list This value will represent the cleared alarm since the temperature now is below T2 Overall this way seems more awkward than the first because the alarm outp
296. y context menu contains commands to cut copy and paste the selected object Aside from using the context menu objects in the tree view can also be copied using the Edit menu from the main window or the keyboard shortcuts The commands Cut and Copy will place a copy of the selected object with all its child objects into the Windows clipboard The copy is therefore not only available for paste into the same project but may also be pasted into another project 7 2 3 1 Data References NOTE 7 2 3 2 Fonts If the copied object tree contains references to data objects these references data point objects are copied without modification For example the copy of an entire page will reference the same data as the original page If the new copy should reference other data objects use the command Manage Data Points from the context menu of the copied object and reassign the data point objects to other data sources as explained in section 7 2 5 If the copy is pasted into a different project the referenced data sources may not be available at all In this case the required data sources are automatically created in the destination project so that the references may be resolved For example it is possible to copy a page which operates on register data only into a completely different project and the page will function the same way it did in the original project Registers which exist for example system registers will be used directly while others
297. y single days but the entire scheduler unit e Edit day patterns of exception days This operation allows write access to the contents of the calendar which is connected to the scheduler unit The user may add remove and edit entries in the calendar which define the days on which a certain exception schedule is active Also linked to this access right is the setting of the exception day priority LOYTEC electronics GmbH L Vis User Manual 71 LOY TEC To change the minimum required access level to perform one of these operations select the operation from the list and select the desired access level from the dropdown box below the list Keep in mind that the minimum access level specified for the entire control on the Common property page must be satisfied in addition to the levels specified here 8 5 10 Alarm List Control NOTE Version 3 1 The alarm list control is a specialized control to display a list of pending alarms from an alarm server or alarm client data point It is possible to connect more than one alarm data point to the same control in which case the control will display a list of all alarms from all connected points in chronological order The control always displays the newest alarm at the top with older alarms following further down At the bottom of the control is a navigation bar which displays the number of pages the list currently uses and allows to navigate through the pages Alarm entries which may be acknowled
298. y the user in a separate dialog For CEA709 devices the configuration software provides a Network Settings Dialog where the required number of scheduler units may be instantiated and their capacity may be configured how many time value entries value templates bytes per value template and so on The dialog can be accessed through the File menu and contains the following options and settings which are relevant to calendar and scheduler functionality of the device e Enable Calendar Object This checkbox enables a LonMark compliant calendar object on the device It is automatically enabled together with local schedulers since the two are always used together e Enable Scheduler Objects This checkbox enables local LonMark compliant scheduler objects on the device Checking this box will automatically enable the calendar as well e Number or calendar entries Specifies the maximum number of different exception schedules day classes like holiday maintenance day supported by this calendar object e Total number of date entries Specifies the maximum number of date definitions which may be stored by the calendar This is the sum of all date LOYTEC electronics GmbH L Vis User Manual 100 LOY TEC NOTE definitions from all calendar entries A date definition is for example a single date a date range or a week and day pattern every last Friday in April e Number of local schedulers This is the number of local scheduler objects w

Download Pdf Manuals

image

Related Search

L Vis l-vision l visa china duration l vision engineering pte ltd la vista la visits l vis 1990 l vision engineering sdn bhd l visa china maximum stay

Related Contents

Addolcitore portatile Cillit-BA Soft 60 Stazione di  TEX48198-019  PREGÃO ELETRÔNICO N.º 03/2014- SESA  JAGS Version 3.3.0 installation manual  取扱説明書 φ85 機械式メーター  Harbor Freight Tools 22 ton Air/Hydraulic Floor Jack Product manual  Click here for the Nano Spotter instruction manual  StarTech.com 1 Port SATA to SATA Slot Plate Bracket  UMFLUXUS_F5PV4-1 DEUTSCH Bedienungsanleitung  Fulltext Document  