Contents

1. 12 Q3Relay Output on CN243 R1R2R3F4C4 Q3 LY 11 NB see graphic 10 108 2sovae Electrical endurance Q1 Q2 Q3 resistive load 5 A 250 Vac resistive loads 10 operations 10 20 2 A 250 Vac cosg 0 3 10 operations 10 0 1 2 3 4 5 6 7 8 S0324 A Switching current A 12 ATR243 User manual 5 1 i SSR output 5 SSR command output 12 V 30 mA min 10 5 V DC Insert JP5 and JP7 and select JP9 as in the figure to use the SSR output 5 1 mA Volt output 5 SSR V mA Linear output in mA configurable using parameters as command parameter c a ut or retransmission of process setpoint parameter rEEr Insert JP5 and JP7 and select JP9 as in figure to use the output in mA Jumpers supplied inside packaging 5 SSR V mA Linear output in Volt configurable using parameters as command parameter c a uL or retransmission of process setpoint parameter rEEr Insert JP5 and JP7 and select JP9 as in figure to use the linear output in Volt Jumpers supplied inside packaging ATR243 User manual 13 5 1 k Current Transformer Input on CN243 R1R2F3 and CN243 R1R2R3F4C4 16 lt Input 50 mA for current transformer 15 Sampling time 80
2. LED ROSSO acceso in programmazione Red Light waiting for programming LED VERDE programmazione eseguita Green Light done NB non possibile trasferire i parametri di uno strumento ad uno con codice differente il LED rimane acceso rosso Aggiornamento CN Config Module Per aggiornare i valori del CN Config Module seguire il procedimento descritto nella prima modalit impostando sul display 2 in modo da non caricare i parametri sul regolatore Entrare in configurazione e variare almeno un parametro Uscendo dalla configurazione il salvataggio sar automatico Nel caso in cui all accensione il regolatore non visualizzi ET o significa che non ci sono dati salvati nel CN Config Module ma possibile ugualmente aggiornarne i valori 62 CN243 Manuale d uso 79 Funzione Latch on Per l impiego con ingresso Fot pot 6 KO e Pot e pot 150 KO e con ingressi normalizzati 0 10 V 0 40 mV 0 4 20 mA possibile associare il valore di inizio scala parametro 6 LaL 1 alla posizione di minimo del sensore e quello di fine scala parametro 7 WPL alla posizione di massimo del sensore parametro 8 LAkc configurato come Std inoltre possibile fissare il punto in cui lo strumento visualizzer 0 mantenendo comunque il campo scala compreso tra LoL e uPL tramite l opzione di zero virtuale impostando JSE oppure u D in nel parametro 8 LA Ec Se si imposta ui D in lo zero virtuale andr
3. V Uscita continua in Volt configurabile da parametri come comando parametro c out o ritrasmissione del processo setpoint parametro rEtr C Inserire JP5 e JP7 e selezionare JP9 come in figura per utilizzare l uscita continua in Volt Jumpers forniti all interno della confezione 56 CN243 Manuale d uso 5 1 k Ingresso T A su CN243 R1R2F3 e CN243 R1R2R3F4C4 16 TA Ingresso per trasformatore amperometrico 50mA risoluzione 1024 punti Tempo di campionamento 80 ms e Configurabile da parametri Inserire JP4 e JP6 come in figura per selezionare l ingresso T A 5 1 1 Ingresso digitale su CN243 R1F2 12V 3 E GND E Ingresso digitale parametro dt 1 L utilizzo dell ingresso digitale in questa versione ID TTT possibile solo con sonde tipo Tc 0 10 V 0 4 20 mA e 0 40 mV Inserire JP3 come in figura per selezionare l ingresso digitale 5 1 m Ingresso digitale su CN243 R1R2F3 e CN243 R1R2R3F4C4 12V GND a De DO Ingresso digitale da parametro dbt i Inserire JP4 come in figura per selezionare l ingresso digitale x Manuale d uso CN243 57 6 Funzione dei visualizzatori e tasti 6 1 Indicatori numerici Display 174
4. Premere Effetto Eseguire i Incrementare o diminuire il l 2 Lacifra sul display 2 varia valore del setpoint principale SET Visualizza setpoint di allarme sul display 1 Incrementare o diminuire il i o Encuesta paa valore del setpoint di allarme 72 Auto Tuning La procedura di Tuning per il calcolo dei parametri di regolazione pu essere manuale o automatica e viene selezionata da parametro 57 E nE 73 Lancio del Tuning Manuale La procedura manuale permette all utente maggiore flessibilit nel decidere quando aggiornare i parametri di regolazione dell argoritmo P I D La procedura pu essere attivata in due modi e Lancio del Tuning da tastiera Premere il tasto finch il display 1 non visualizza la scritta tunE con il display 2 su aFF premere A il display 2 visualizza an Il led TUN si accende e la procedura ha inizio e Lancio del Tuning da ingresso digitale Selezionare EunE su parametro 61 dit Alla prima attivazione dell ingresso digitale commutazione su fronte il led TUN si accende alla seconda si spegne Manuale d uso CN243 59 74 Lancio del Tuning Automatico Il Tuning automatico si attiva all accensione dello strumento o quando viene modificato il setpoint di un valore superiore al 35 Per evitare overshoot il punto dove il regolatore calcola i nuovi parametri PID determinato dal valore di setpoint meno il valore Set Deviation Tune vedere parametro 58 S d Eu Per interromper
5. Permette di misurare la corrente sul carico per gestire un allarme in caso di malfun zionamento con stadio di potenza in corto oppure sempre aperto Il trasformatore amperometrico collegato ai morsetti 15 e 16 deve essere da 50 mA tempo di campionamento 80 ms Impostare sul parametro 47 E H il valore di fondo scala in Ampere del trasformatore amperometrico Impostare sul parametro 48 L b A t la soglia di intervento in Ampere del Loop Break Alarm Impostare sul parametro 49 L b A d il tempo di ritardo per l intervento del Loop Break Alarm e possibile associare l allarme ad un rel impostando il parametro AL FL Z oppure HL J comeL b A Nel caso un teleruttore o rel allo stato solido dovesse restare sempre chiuso il regolatore segnala il guasto visualizzando L b H c sul display 2 alternativamente con il setpoint di comando Nel caso invece lo stadio di potenza dovesse restare sempre aperto oppure la corrente sul carico fosse inferiore al valore impostato su L b H E il regolatore visualizza sul display 2 L b Al o possibile visualizzare la corrente assorbita in fase di chiusura dello stadio di potenza Premere Effetto Eseguire Premere fino alla Questo tasto in modo ciclico visualizzazione sul display permette di visualizzare 1 della scritta Afl t 7 e sul 1 SET sul display 2 percentuale di display 2 della corrente in uscita selezione auto man Ampere E R 0 Il valore setpoint ed all
6. eventuale mancanza di alimentazione H35 E Alarm 3 State Error Stato del contatto per l uscita di allarme 3 in caso di errore c 0 Contatto aperto Default C C Contatto chiuso H3Ld Alarm 3 LED Definisce lo stato del led OUT3 in corrispondenza del relativo contatto c a Acceso a contatto aperto EN Acceso a contatto chiuso Default ASHY Alarm 3 Hysteresis Isteresi allarme 3 999 999 digit gradi decimi per sensori di temperatura Default 0 0 H3 dE Alarm 3 Delay Ritardo allarme 3 180 180 secondi Default 0 Negativo ritardo in fase di uscita dall allarme Positivo ritardo in fase di entrata dell allarme H 35 P Alarm 3 Setpoint Protection Protezione set allarme 3 Non consente all operatore di variare il valore impostato FrEE Modificabile dall utente Default Lack Protetto HidE Protetto e non visualizzato 10 11 All accensione l uscita inibita se lo strumento in condizione di allarme Si attiva solo quando rientrato dalla condizione d allarme questa si ripresenta Dipende dall impostazione del parametro 5E n e del parametro d P Manuale d uso CN243 79 47 48 49 50 51 52 53 EN Amperometric Transformer Abilitazione e range di fondo scala del trasformatore amperometrico 0 Disabilitato 1 200 Ampere Default 0 L b H E Loop Break Alarm Threshold Soglia di intervento del Loop Break Alarm 0 0 200 0 Ampere Default 50 0 L b H d Loop Break Alarm
7. 30mA PRESSURE TRANSMITTER ALIMENTAZIONE ESTERNA For signals 0 4 20 mA with external power of sensor EXTERNAL SUPPLY 2 E Comply with polarity A Sensor output B Sensor ground SENSOREDIPRESSIONE PRESSURE TRANSMITTER 12V 73 0 30 mA 3 4 20mA Comply with polarity VIA TM A Sensor output La C Sensor power supply 12Vdc 30mA For signals 0 4 20 mA with two wire sensor 5 1 d Serial Input only CN243 R1R2F3 12 77 7 O8 FERT DW RS485 Modbus RTU communication 11 7 72 Ga Sghisid Schemie 5 1 e Relay Q1 Output L 8 Capacity 5 A 250 V for resistive loads Q1 M 7 NB see graphic next page E M ATR243 User manual 11 5 1 f Relay Q2 output for CN243 R1F2 14 Capacity 5 A 250 V for resistive loads To select Q2 as relay output verify that jumpers JP5 and pai JP7 are not inserted NB see graphic next page je sje 2 0 Connecting a load without removing the E l i3 jumpers will permanently damage the P controller lt 5 1 g Relay Q2 output for CN243 R1R2F3 and CN243 R1R2R3F4C4 d 14 _ Capacity 5 A 250 V for resistive loads Q2 13 _ NB see graphic 5 1 h Relay Q3 output for CN243 R1R2R3F4C4
8. ATR243 User manual 41 42 43 44 45 46 47 48 H3rE Alarm 3 Reset Alarm 3 contact reset type HrE Automatic reset Default HrE Manual reset irt Manual reset stored keeps relay status also after an eventual power failure H35 E Alarm 3 State Error State of contact for alarm 3 output in case of error c n Open contact Default C C Closed contact H3Ld Alarm3LED State of OUT3 led corresponding to relative contact Go ON with open contact Lil ON with closed contact Default ASHY Alarm 3 Hysteresis 999 999 digit degrees tenths for temperature sensors Default 0 0 H3 dE Alarm 3 Delay 180 180 seconds Negative delay in alarm exit phase Positive delay in alarm entry phase Default 0 H 35 P Alarm 3 Setpoint Protection Alarm 3 set protection Does not allow operator to change the setpoint value Free Modification allowed Default Lock Protected Hide Protected and not visualized L A Current Transformer Activation and scale range of current transformer 0 Disabled 1 200 Ampere Default 0 L b H E Loop Break Alarm Threshold Intervention threshold of Loop Break Alarm 0 0 200 0 Ampere Default 50 0 11 Display of decimal point depends on setting of parameter 5 E n and parameter d P ATR243 User manual 37 49 50 51 52 53 54 L b H d Loop Break Alarm Delay Delay time for Loop break alarm intervention 00 00 60 00 mm ss Default 0
9. Pv K Hysteresis parameter ole Absolute alarm with controller in cooling 3 N Alamspv functioning par 11 Act t selected Cool and hysteresis value than 0 par 28 A H49 gt 0 On On Al arm or RMS or Motto Time Alarm Spv Absolute alarm with controller in cooling functioning par 11 Hc E E selected CooL and teresis parameter hysteresis value less than 0 par 28 A IHH lt 0 On On off rail Off m ae utpu 11 6 Absolute Alarm or Threshold Alarm Referring to Setpoint Command A c AL selection Comand Spv Hysteresis Absolute alarm refers to the command set LIA gt 0 with the controller in heating functioning par las spy 11 Het t selected HERE and hysteresis value 1 greater than 0 par 28 A LH4Y gt 0 The command set can be changed by pressing p S the arrow keys on front panel or using serial On port RS485 commands Off or Alarm output 11 c Band Alarm b AL selection Pv Va i Nam Spy y hg Hysteresis Corian Spr parameter PA l iM4 0 unn M Band alarm hysteresis value greater than 0 1 4 Alarm Spv par 28 A HH gt 0 gt Time On on On Alarm EH NN MM o Alarm ATR243 User manual 43 Hysteresis arameter _LHY lt 0 PRU Se Alarm Spv Wim Band alarm hysteresis value less than 0 par gt a dt Wem 28 A 1HY lt 0 AHY lt
10. Command output must be configured as Heating P I D Hc E E HERE and with a Pb greater than 0 and one of the alarms AL i HL Cor AL 3 must be configured as canat Command output must be connected to the actuator responsible for heat while the alarm will control cooling action Parameters to configure for the Heating P I D are Act t HERE Command output type Heating F b Heating proportional band E i Integral time heating and cooling E d Derivative time heating and cooling t c Heating time cycle Parameters to configure for the Cooling P I D are the following ex action associated to alarm 1 AL cool Alarm 1 selection Cooling F h f Proportional band multiplier ou d b Overlapping Dead band co t c Cooling time cycle Parameter P h 1 that ranges from 1 00 to 5 00 determines the proportional band of cooling basing on the formula Cooling proportional band P5 x P H fl This gives a proportional band for cooling which will be the same as heating band if P 5 1 1 00 or 5 times greater if F h f 5 00 Integral and derivative time are the same for both actions Parameter ou d b determines the percentage overlapping between the two actions For systems in which the heating and cooling output must never be simultaneously active a dead band au d b lt 0 can be configured and vice versa an overlapping ou d b gt 0 The following figure shows an example of dual action P I D heatin
11. Slave Address Serial Delay Lower Limit Output Percentage 90 CN243 Manuale d uso 81 81 81 82 82 82 82 82 82 82 83 83 84 84 84 84 85 85 85 85 85 85 86 86 86 86 86 86 87 87 WARRANTY DISCLAIMER OMEGA ENGINEERING INC warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase OMEGA s Warranty adds an additional one 1 month grace period to the normal one 1 year product warranty to cover handling and shipping time This ensures that OMEGA s customers receive maximum coverage on each product If the unit malfunctions it must be returned to the factory for evaluation OMEGA s Customer Service Department will issue an Authorized Return AR number immediately upon phone or written request Upon examination by OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limited to mishandling improper interfacing operation outside of design limits improper repair or unauthorized modification This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion or current heat moisture or vibration improper specification misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not wa
12. per esempio all allarme 1 HL I cool Selezione allarme 1 Freddo Fb Si Moltiplicatore di banda proporzionale nu d b Sovrapposizione Banda morta co t c Tempo di ciclo azione freddo Il parametro P 5 71 che varia da 1 00 a 5 00 determina la banda proporzionale dell azione refrigerante secondo la formula Banda proporzionale azione refrigerante Pb x Pb Si avr cosi una banda proporzionale per l azione refrigerante che sar uguale a quella dell azione caldo se F b 1 00 o 5 volte pi grande se Pb 5 00 Tempo integrale e Tempo derivativo sono gli stessi per entrambe le azioni Il parametro ou d b determina la sovrapposizione in percentuale tra le due azioni Per gli impianti in cui l uscita riscaldante e l uscita refrigerante non devono mai essere attive contemporaneamente si configurer una Banda morta ou d b x 0 viceversa si potr configurare una sovrapposizione ou d b gt 0 Manuale d uso CN243 65 P b x P b fl COOL ou db lt 0 P b HEAT i ACTIVE L COMMAND OUTPUT HEAT ACTIVE i ALARM OUTPUT COOL P b x P b COOL SPV ACTIVE COMMAND OUTPUT HEAT ACTIVE i ALARM OUTPUT COOL P b x P b COOL MEN lend A P b HEAT ESSE COMMAND OUTPUT HEAT ACTIVE ALARM OUTPUT COOL Il parametro co t c ha lo stesso significato del tempo di ciclo per l azione caldo E c Il parametro ran F fluido di raffreddamento pre selezi
13. used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT IN ORDER TO AVOID PROCESSING DELAYS The assigned AR number should then be marked on the outside of the return package and on any correspondence The purchaser is responsible for shipping charges freight insurance and proper packaging to prevent breakage in transit FOR WARRANTY RETURNS please have FOR NON WARRANTY REPAIRS consult OMEGA the following information available BEFORE for current repair charges Have the following contacting OMEGA information available BEFORE contacting 1 Purchase Order number under which the OMEGA product was PURCHASED 1 Purchase Order number to cover the COST 2 Model and serial number of the product of the repair under warranty and 2 Model and serial number of the product and 3 Repair instructions and or specific 3 Repair instructions and or specific problems problems relative to the product relative to the product OMEGA s policy is to make running cha
14. visualizzato il SET1 mentre la label del SET2 diventa semplicemente SET In questa modalit lanciando il tune manuale durante la regolazione sul SET1 non si vedr accendersi il led TUN finch non si passer alla regolazione sul SET2 L autotuning automatico e manuale funziona ma solo se sta regolando sul SET2 Se viene lanciato durante la regolazione sul SET1 rimane in standby per poi partire appena si passa alla regolazione sul SET2 Manuale d uso CN243 61 7 8 CN Config Module opzionale possibile duplicare parametri e setpoint da un regolatore ad un altro mediante l uso del CN Config Module Sono previste due modalit Con regolatore connesso all alimenta zione Inserire il CN Config Module con regolatore spento All accensione il display 1 visualizza MEflo e il display 2 visualizza solo se nel CN Config Module sono salvati valori corretti Premendo il tasto il display 2 visualizza La Hd Confermare con il tasto ser Il regolatore carica i nuovi valori e riparte Con regolatore non connesso all ali mentazione Il CN Config Module dotato di batteria interna con autonomia per circa 1000 utilizzi batteria a bottone 2032 sostituibile Inserire il CN Config Module e premere il tasto di programmazione Durante la scrittura dei parametri il led si accende rosso al termine della procedura si accende verde E possibile ripetere la procedura senza particolari attenzioni
15. 0 3004 Quarta word display 1 ascii R W 0 3005 Quinta word display 1 ascii R W 0 3006 Sesta word display 1 ascii R W 0 3007 Settima word display 1 ascii R W 0 3008 Ottava word display 1 ascii R W 0 3009 Prima word display 2 ascii R W 0 3010 Seconda word display 2 ascii R W 0 3011 Terza word display 2 ascii R W 0 3012 Quarta word display 2 ascii R W 0 3013 Quinta word display 2 ascii R W 0 3014 Sesta word display 2 ascii R W 0 3015 Settima word display 2 ascii R W 0 3016 Ottava word display 2 ascii R W 0 Manuale d uso CN243 69 Modbus Address 3017 Descrizione Word LED BitO LED C1 Bit 1 LED C2 Bit 2 LED A1 Bit 3 LED A2 Bit 4 LED A3 Bit 5 LED MAN Bit 6 LED TUN Bit 7 LED REM Read Only R W Reset value 3018 Word tasti scrivere 1 per assumere il controllo dei tasti Bit 0 Bit 1 Bit 2 R W 3019 Word rel seriale Bit 0 Rel Q1 Bit 1 Rel Q2 Bit 2 Rel Q3 R W 3020 Word SSR seriale 0 Off 1 On R W 3021 Word uscita 0 10 V seriale 0 10000 R W 3022 Word uscita 4 20 mA seriale 0 10000 R W 3023 Word stato rel in caso di off line solo se controllati da seriale Bit 0 Rel Q1 Bit 1 Rel Q2 Bit 2 Rel Q3 R W 3024 Word stato uscita SSR 0 10 V 4 20 mA in caso di off line solo se controllati da seriale 0 10000 R W 3025 Word processo seria
16. 21 31ABC 3 2 Caratteristiche Hardware Alimentazione Alimentazione a range esteso 24 230 Vac Vdc 15 50 60 Hz Consumo 5 5 VA Ingresso analogico 1 AN1 Configurabile via software Ingresso Termocoppie tipo K S R J Compensazione automatica del giunto freddo da 0 50 C Termoresistenze PT100 PT500 PT1000 Ni100 PTC1K NTC10K 8 3435K OMEGA NTC2252 OMEGA Ingresso V I 0 10 V 0 200 4 20 mA 0 40 mV T A 50 mA 1024 punti su versione CN243 R1R2F3 R1R2R3F4C4 Ingresso Pot 6 KO 150 KO Tolleranza 25 C 0 2 1 digit su F s per termocoppia termoresistenza e V mA Precisione giunto freddo 0 1 C C Impedenza 0 10 V Ri gt 110 KQ 0 20 mA Ri lt 5 Q 4 20 mA Ri lt 5 O 0 40 mV Ri gt 1 MO 2 Rel CN243 R1F2 R1R2F3 Contatti f 3 Rel CN243 R1R2R3F4C4 5A 250 V Uscite rel l l Ra Configurabili come uscita Carico resistivo comando e allarme 1 SSR 12V 30mA min 10 5 V DC Normalizzata 0 4 20mA o Configurabile 0 10 Volt 0 10 V con 9500 punti 0 2 Uscita SSR V mA e Deselezionando rel OUT2 suF s su CN243 R1F2 Configurabili come uscita comando o ritrasmissione setpoint o processo 0 20 mA con 7500 punti 0 2 su F s 4 20 mA con 6000 punti 0 2 su F s Manuale d uso CN243 49 3 3 Caratteristiche Software Algoritmi ON OFF con isteresi regolazione P P I P I D P D a tempo proporzionale Panca 0 9999 C
17. A For possible extensions use a compensated wire ET I gt and terminals suitable for the thermocouples used 1 Sud compensated Sasa e When shielded cable is used it should be grounded at one side only Shield Schermo 3 Re For thermoresistances PT100 NI100 For the three wire connection use wires with the same section For the two wire connection short circuit terminals 1 and 3 When shielded cable is used it should be grounded at one side only Select internal jumper JP3 as in the figure RED al WHITE EHE RED mA For thermoresistances NTC PTC PT500 PT1000 e poten tiometers When shielded cable is used it should be grounded at one side only to avoid ground loop currents For linear signals V mA Comply with polarity When shielded cable is used it should be grounded at one side only Select internal jumper JP3 as in the figure If jumpers are not properly selected 12 Vdc 30 mA are not available on terminal 3 to power the sensor 10 ATR243 User manual 5 1 c Example of Connection for linear input Volt and mA 12V 3 30 mA For signals 0 10 V 2 lt 0 10V 5 Comply with polarity V A 1 D SENSORE DIPRESSIONE PRESSURE TRANSMITTER For signals 0 4 20 mA with three wire sensor Comply with polarity A Sensor output B Sensor ground C Sensor power 12Vdc
18. A current OFF Ampere with tenths RO 1022 OFF LINE time milliseconds R W 1023 Instant Current Ampere R W 0 1024 Digital Input State R W 0 Synchronized Tuning for multizone system 0 Tuning OFF Normal operating of the regulator 1 Output command OFF 1025 2 Output command ON R W 0 3 Start Tuning 4 EndTuning and output command OFF Write 0 for normal operating 1099 Process subjected to the visualization filter and RO decimal point selection 1100 Process with decimal point selection RO 1101 Setpoint 1 with decimal point selection R W EEPROM 26 ATR243 User manual Modbus Reset Addas Description Read Only e 1102 Setpoint 2 with decimal point selection R W EEPROM 1103 Setpoint 3 with decimal point selection R W EEPROM 1104 Setpoint 4 with decimal point selection R W EEPROM 1105 Alarm 1 with decimal point selection R W EEPROM 1106 Alarm 2 with decimal point selection R W EEPROM 1107 Alarm 3 with decimal point selection R W EEPROM 1108 Gradient Setpoint with decimal point selection RO EEPROM 1109 Percentage heating output 0 1000 R W 0 1110 Percentage heating output 0 100 RO 0 1111 Percentage cooling output 0 1000 RO 0 1112 Percentage cooling output 0 100 RO 0 2001 Parameter 1 R W EEPROM 2002 Parameter 2 R W EEPROM 2072 Parameter 72 R W EEPROM 3000 Disabling serial control of machine RO 0 3001 First word display 1 ascii R W
19. Function Offset Calibration Gain Calibration Action type Command Reset Command State Error Command Led Command Hysteresis Command Delay Command Setpoint Protection Proportional Band Integral Time Derivative Time Cycle Time Output Power Limit Alarm 1 Alarm 1 State Output Alarm 1 Reset Alarm 1 State Reset Alarm 1 Led Alarm 1 Hysteresis Alarm 1 Delay Alarm 1 Setpoint Protection Alarm 2 Alarm 2 State Output Alarm 2 Reset Alarm 2 State Error Alarm 2 Led Alarm 2 Hysteresis Alarm 2 Delay Alarm 2 Setpoint Protection Alarm 3 Alarm 3 State Output Alarm 3 Reset Alarm 3 State Error Alarm 3 LED 46 ATR243 User manual 29 31 31 31 31 31 31 32 32 32 32 32 32 32 33 33 33 33 33 33 33 33 34 34 34 34 34 34 35 35 35 35 35 35 36 36 36 36 36 36 37 37 37 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 ASH HE H35 P EH LEE Lb A con F P bJ oud h EB EJ LE E Frn u FLE tune S dbu oF Slo Au A OE 1 GrAd MALE i ce Ler TER ti dEbr FEEF Lad oP ioe bd rt SL Mg SE HE Liar Alarm 3 Hysteresis Alarm 3 Delay Alarm 3 Setpoint Protection Current Transformer Loop Break Alarm Threshold Loop Break Alarm Delay Cooling Fluid Proportional Band Multiplier Overlap Dead Band Cooling Cycle Time Conversion Filter Conversion Frequency Visualization Filter Tune Setpoint D
20. R W EEPROM 1004 Setpoint 4 R W EEPROM 1005 Allarme 1 R W EEPROM 1006 Allarme 2 R W EEPROM 1007 Allarme 3 R W EEPROM 1008 Setpoint gradiente RO EEPROM Stato rel 0 Off 1 On Bit 0 Rel Q1 1009 Bit 1 Rel Q2 RO 0 Bit 2 Riservato Bit 3 SSR 1010 Percentuale uscita caldo 0 10000 RO 0 1011 Percentuale uscita freddo 0 10000 RO 0 Stato allarmi 0 Assente 1 Presente 1012 Bit 0 Allarme 1 Bit 1 Allarme 2 Bit 2 Allarme 3 ne i Riarmo manuale scrivere 0 per riarmare tutti gli allarmi 1013 In lettura 0 Non riarmabile 1 Riarmabile WO 0 Bit 0 Allarme 1 Bit 1 Allarme 2 Bit 2 Allarme 3 Flags errori Bit O Errore scrittura eeprom Bit 1 Errore lettura eeprom Bit 2 Errore giunto freddo 1014 Bit 3 Errore processo sonda RO 0 Bit 4 Errore generico Bit 5 Errore hardware Bit 6 Errore L B A O Bit 7 Errore L B A C Bit 8 Errore tarature mancanti 1015 Temperatura giunto freddo gradi decimi RO Start Stop 1916 0 regolatore in STOP 1 regolatore in START oe o Lock conversion ON OFF 1917 0 Lock conversion off 1 Lock conversion on bid o Tuning ON OFF HS 0 Tuning off 1 Tuning on RM o Selezione automatico manuale 1093 0 Automatico 1 Manuale RAN o 1020 Corrente T A ON ampere con decimo RO 1021 Corrente T A OFF ampere con decimo RO 1022 Tempo OFF LINE millisecondi R W 68 CN243 Manuale d uso Modbus Read Reset Address peserizione Only value 1023 Corrent
21. Time On On On i Alarm Off Off Off output g Theexample refers to alarm 1 the function can also be enabled for alarm 2 and 3 on models that include it 11 d Upper Deviation Alarm H d FIL selection Pw vata N Alarm Spv 4 Hysteresis arameter AiHy gt 0 Upper deviation alarm value of alarm setpoint 1 P ComandSpv greater than 0 and hysteresis value greater than 0 par 28 A LHH gt 0 gt Time On On A or MEN Off 2 gt output Pv a N Comand Spv 7 Alarm Spv 0 gm Upper deviation alarm value of alarm setpoint 2 Pi m less than 0 and hysteresis value greater than ad LS 0 par 28 RH HW gt 0 Time On On i arm or i ot EHI output 11 e Lower Deviation Alarm L d FL selection Pv fx Ri Comand Spv _ Hysteresis 2s e parameter Lower deviation alarm value of alarm setpoint 1 E greater than 0 and hysteresis value greater Po Alarm Spv than 0 par 28 H H4 gt 0 Time On Alarm EN o E o5 5055 44 ATR243 User manual Hysteresis ponet H 4H3 20 fota IA Alarm Spv Time On On l AI ex arm ENEN of za comandspy Lower deviation alarm value of alarm setpoint less than 0 and hysteresis value greater than 0 par 28 AL LH gt 0 The example refers to alarm 1 the function can also be enabled for alarms 2 and 3
22. as 0 10 V with 9500 points 0 2 output command output orretransmis F s sion of setpoint or process 0 20 mA with 7500 points 0 2 F s 4 20 mA with 6000 points 0 2 F s 3 3 Software data Regulation ON OFF with hysteresis algorithms P P I P I D P D with proportional time Proportiotal 0 9999 C or F band Integral time 0 0 999 9 sec 0 excludes integral function Derivative time 0 0 999 9 sec 0 excludes derivative function Manual or automatic Tuning configurable alarms protection of Controller SE SER Faeroe command and alarm setpoints activation of functions via digital input preset cycle with Start Stop 6 ATR243 User manual 4 Dimensions and Installation DIMA DI FORATURA CN CONFIG MODULE FRONTAL PANEL optional CUT OUT 46 X 46 mm em m m 3 Cree Er mL E a x EA 2 co m E i SIE ni z W is pa mm za IW mi ccc at 48 mm 10 5 106 5 mm 18 EFE SEIT c e o umm 3 emm 9 ED A PRI 1 SB 000000 DI Ga Suggested thickness Spessore suggerito 2 6 mm ATR243 User manual 7 4 1 Panel Assembly To dismantle use a screwdriver and slightly force the fixing hooks to remove them from the fixing guide Method of panel assembly and fixing of anchorage
23. display due appare Aiuto Premere il tasto per visualizzare fiHn ora possibile durante la visualizzazione del processo variare con i tasti e la percentuale dell uscita Per tornare in automatico con la stessa procedura selezionare Hut n sul display 2 subito si spegne il led TUN e il funzionamento torna in automatico 2 Laseconda selezione En St abilita lo stesso funzionamento ma con due importanti varianti e Nel caso di temporanea mancanza di tensione o comunque dopo uno spegnimento accendendo il regolatore verr mantenuto sia il funzionamento in manuale sia il valore di percentuale dell uscita precedentemente impostato e Nel caso di rottura del sensore durante il funzionamento automatico il regolatore si porter in manuale mantenendo invariata la percentuale di uscita comando generata dal P I D subito prima della rottura Es su un estrusore viene mantenuto il comando in percentuale della resistenza carico anche nel caso di guasto sulla sonda in ingresso 60 CN243 Manuale d uso 7 7 Ciclo pre programmato La funzione ciclo pre programmato si abilita impostando Pr cH oppure Pc 55 nel parametro 59 oF Vo Prima selezione P c4 il regolatore raggiunge il setpoint 1 RS seguendo il gradiente impostato nel E capot parametro 62 L Ad poi sale alla massima E eas Raffreddamento potenza verso il setpoint 2 Quando il potenza pones processo lo raggiunge lo mantiene per Setpoint 1 il tempo impostato nel param
24. for temperature sensors RO digits for linear sensors 1001 Setpoint 1 R W EEPROM 1002 Setpoint 2 R W EEPROM 1003 Setpoint 3 R W EEPROM 1004 Setpoint 4 R W EEPROM 1005 Alarm 1 R W EEPROM 1006 Alarm 2 R W EEPROM 1007 Alarm 3 R W EEPROM 1008 Setpoint gradient RO EEPROM Relay status 0 Off 1 On Bit 0 Relay Q1 1009 Bit 1 Relay Q2 RO 0 Bit 2 Reserved Bit 3 SSR 1010 Heating output percentage 0 10000 RO 0 ATR243 User manual 25 Mou Description Read Only E 1011 Cooling output percentage 0 10000 RO 0 Alarms status 0 None 1 Active 166 Bit 0 Alarm 1 Bit1 Alarm2 Bit2 Alarm3 da g Manual reset write 0 to reset all alarms 1013 In reading 0 Not resettable 1 Resettable WO 0 Bit 0 Alarm 1 Bit Alarm2 Bit 2 Alarm 3 Error flags Bit 0 Eeprom writing error Bit 1 Eeprom reading error Bit 2 Cold junction error Bit 3 Process error sensor iu Bit 4 Generic error no o Bit 5 Hardware error Bit 6 L B A O error Bit 7 L B A C error Bit 8 Missing calibration data error 1015 Cold junction temperature degrees tenths RO Start Stop 1016 0 Controller in STOP R W 0 1 Controller in START Lock conversion ON OFF 1017 0 Lock conversion off R W 0 1 Lock conversion on Tuning ON OFF HHS 0 Tuning off 1 Tuning on RAN i Automatic manual selection 101 0 Automatic 1 Manual iid o 1020 T A current ON Ampere with tenths RO 1021 T
25. hooks 4 2 Electronics Removal To remove the electronics grip the front part using the two specific side ridges 2 L AN Disconnect the device from the mains before starting to configurate or service it 8 ATR243 User manual 5 Electrical wirings Although this controller has been designed environment please notice the following safety guidelines Separate control lines from the power wires Avoid the proximity of remote control switches electromagnetic meters powerful engines to resist noises in an industrial Avoid the proximity of power groups especially those with phase control 5 1 Wiring diagram 16 12 GND 10 SUPPLY Talons Erice 14 Q2 H o He 4 SSR V mA Ge 4p 3 15 1D TA PTC PT100 1 8HP In RS485 Q1 5A230V Resistive 1 8HP CN243 R1R2F3 5 1 a Power 10 24 230V AC DC Q LI a PTC PT100 NTC NI100 SSR V mA 4 PTC PT100 NTC NI100 12 DETUR E 2 SSR V MHI mA GL CAUTION Risk of Electric Shock 1ol suPeLy ne at 22 EP ed CN243 R1F2 CN243 R1R2R3F4C4 Switching power supply with extended range 24 230 Vac dc 15 50 60 Hz 5 5 VA with galvanic isolation ATR243 User manual 9 5 1 6 AN1 Analogue Input For thermocouples K S R J OOLIN Ld Shield Schermo e Comply with polarity 2 5
26. o F proporzionale Tempo integrale 0 0 999 9 sec 0 esclude funzione integrale Tempo derivativo 0 0 999 9 sec 0 esclude funzione derivativa Tuning manuale o automatico allarme selezionabile protezione set comando e allarme selezione funzioni da ingresso digitale ciclo pre programmato con Start Stop Funzioni del regolatore 4 Dimensioni ed installazione DIMA DI FORATURA CN CONFIG MODULE FRONTAL PANEL optional CUT OUT 46 X46 mm E M a c BEND 78 IRC o Si acdan BEN E ia im iex e EH P s me g AI ee e PTC PT100 lt ITC NH00 DI L im 12 8 2 asp gii 79 ON E Ea Te TT ee 5 3 va mH Db Js PU I E el Go lt 8 al gt i i ee Suggested thickness Spessore suggerito 2 6 mm 50 CN243 Manuale d uso 434 Montaggio a pannello GGoGGE UE ii N if dim 2 Per lo smontaggio utilizzare un cacciavite e forzare leggermente i ganci di fissaggio Modalit di montaggio a pannello e per farli uscire dalla guida di ancoraggio fissaggio per ganci di ancoraggio 4 2 Estrazione dell elettronica Per estrarre l elettronica impugnare la parte frontale nelle due apposite zigrinature laterali 2 2 L Prima di effettuare
27. on models that include it b With hysteresis value less than 0 1 HH lt 0 the broken line moves under the alarm setpoint 12 Table of Anomaly Signals If installation malfunctions controller will switch off regulation output and will report the anomaly For example controller will report failure of a connected thermocouple visualizing E 5 flashing on display for other signals see table below Cause what to do E 01 Error in EEPROM cell Call Assistance 5Y5 E programming Cold junction sensor fault or E 02 Cu E room temperature outside of Call Assistance i allowed limits E 04 ncorreci configuration data Check if the configuration CYS E Possible loss of calibration iii i values P E 05 Thermocouple open or Check the connection with the 5u5 E temperature outside of limits sensors and their integrity ee Missing calibration data Call Assistance SUSE 3 Notes Updates ATR243 User manual 45 Table of configuration parameters COIN AD UW B W N Louk Sen dF LoS uL LOL uPL i LHEc 9 n cH 10 L cH 11 fTebkE 12 c 32 Fran N o nzm nbrmrm unmninnin FE Ji Ld H3 ge IF 33 MEE 34 ASE 35 Acid 36 HgHd 37 Mrd 38 Mese 39 HL 3 40 H3i5n 4 Hirt 42 RAIRE 43 Hd Command Output Sensor Decimal Point Lower Limit Setpoint Upper Limit Setpoint Lower Linear Input Upper Linear Input Latch On
28. primo ordine zj Pres IL oO IMNLTUNUN E3 in un un tn un un un un n p epopea c r r 57 tunE Tune Selezione tipo autotuning Vedi paragrafo 7 2 da Disabilitato Default Auto Automatico Calcolo parametri P I D all accensione e al variare del set Hn Manuale Lanciato dai tasti o da ingresso digitale 5Hnc Sincronizzato Vedere word modbus 1025 solo CN243 R1R2F3 58 5 dtu Setpoint Deviation Tune Imposta la deviazione dal setpoint di comando come soglia usata dall autotuning per il calcolo dei parametri P I D 0 5000 digit decimi di grado se temperatura Default 10 59 oF fic Operating Mode Selezione funzionamento Vedi paragrafo 11 cont Regolatore Default Pr cH Ciclo pre programmato Vedi paragrafo 7 7 CES Cambio set da ingresso digitale 2t 5 1 Cambio set da ingresso digitale con comando ad impulso 4t 5 1 Cambio di 3 set da ingresso digitale con comando ad impulso 4e 5 1 Cambio di 4 set da ingresso digitale con comando ad impulso k rES Time reset funzione personalizzata P c 5 5 Ciclo pre programmato con Start Stop solo da ingresso digitale 5 c4 ComePr cH ma con alcune varianti 12 Dipende dall impostazione del parametro 5E n e del parametro d F 82 CN243 Manuale d uso 60 AL NA Automatic Manual 61 62 63 Abilita la selezione automatico manuale Vedi paragrafo 7 6 gas Disabilitato Default En Abilitato En 5t Abilitato con memoria dit 1 Digita
29. qualsiasi operazione di configurazione o di manutenzione disinserire l apparecchio dalla rete Manuale d uso CN243 51 5 Collegamenti elettrici Bench questo regolatore sia stato progettato per resistere ai piu gravosi disturbi presenti in ambienti industriali buona norma seguire la seguenti precauzioni e Distinguere la linea di alimentazioni da quelle di potenza e Evitare la vicinanza di gruppi di teleruttori contattori elettromagnetici motori di grossa potenza e comunque usare gli appositi filtri Evitare la vicinanza di gruppi di potenza in particolare se a controllo di fase 5 1 Schema di collegamento Di seguito sono riportati i collegamenti dei tre modelli disponibili 10 SUPPLY co si 8 24 230V o Fi x GEE s Acc PTC PT100 255 st NTC NI100 5023 3 12 oge 38 O Lea i i 5 1 a 2 s23 a bc Ga a 6 CN243 R1F2 16 12 6ND l o SUPPLY SSRIVIMA SSR VImA 24 230V g c 15 ip TA o ACIDE PTC PT100 PTC PT100 NTCNI100 NTCNI100 14 12 14 a2 8 13 5A 230V Sy aie 7 a 12 uH CN243 R1R2F3 CN243 R1R2R3F4C4 Q3 5 1 a Alimentazione 10 Alimentazione switching a range esteso SUPPLY ci 24 230 Vac dc 15 50 60 Hz 5 5 VA gl con isolamento galvanico 5 1 6 Ingresso analogico AN1 Shield Schermo Per termocoppie K S R J Ar es Rispettare la polarit 2 Y m e Per eventuali prolunghe
30. receive the command but no response is expected CN243 can introduce a delay in milliseconds in the response to the master request This delay must be set on parameter 72 5E dE Each parameter change is saved by the controller on EEPROM memory 100000 writing cycles while the setpoints are saved with a delay of ten seconds after the last change NB changes made to Words that are different from those reported in the following table can lead to malfunction 24 ATR243 User manual Modbus RTU protocol features Selection on parameter 70 bd rt 44 4 800 bit Sec HB 9 600 bit Sec Baud rate F cr 19 200 bit Sec 28 H 28 800 bit Sec 38H 38 400 bit Sec 5 1 BF 57 600 bit Sec Format 8 N 1 8 bit no parity 1 stop Supported WORD READING max 20 word 0x03 0x04 functions SINGLE WORD WRITING 0x06 MULTIPLE WORDS WRITING max 20 word 0x10 Looking at the table here below it is possible to find all available addresses and functions RO Read Only R W Read Write WO Write Only heiss Description Read Only es 0 Device type RO EEPROM 1 Software version RO EEPROM 5 Slave address R W EEPROM 6 Boot version RO EEPROM 50 Automatic addressing WO 51 System code comparison WO 500 Loading default values write 9999 R W 0 510 Setpoints storing time in eeprom 0 60 s R W 10 999 Process subjected to the visualization filter RO 1000 Process degrees tenths
31. reimpostato dopo ogni accensione dello strumento se si imposta u USt lo zero virtuale rester fisso una volta tarato Impostando dn 1 dynamic limits permette di superare i limiti inferiore e superiore se in ingresso ci sono valori esterni al 0 4 20mA o 0 10V Per utilizzare la funzione LATCH ON configurare come desiderato il parametro LRE c Per la procedura di taratura fare riferimento alla seguente tabella Premere Effetto Eseguire Posizionare il sensore a CW Esce dalla configurazione Ko 1 seared ava sul valore minimo di contemporanea Parametri o funzionamento associato a mente visualizza la scritta LAE c roi Lola Posizionare il sensore gt Fissa il valore sul minimo sul valore massimo di Il display visualizza Lol funzionamento associato a uF Per uscire dalla procedura standard tenere premuto str Fissa il valore sul massimo i 3 Ah s a Nel caso di impostazione con Il display visualizza H LH 7 Bl zero virtuale posizionare il sensore nel punto di zero Fissa il valore di zero virtuale Il display visualizza urb NB nel caso di selezione Per uscire dalla procedura 4 SET M uO n la procedura al tenere premuto ser punto 4 va eseguita ad ogni ri accensione SV A ce ta procedura di taratura parte uscendo dalla configurazione dopo aver variato il parametro Manuale d uso CN243 63 7 10 Loop Break Alarm da ingresso T A Trasformatore Amp
32. secondi dall ultima modifica NB modifiche apportate a Word diverse da quelle riportate nella tabella seguente possono causare mal funzionamenti dello strumento Caratteristiche protocollo Modbus RTU Selezionabile da parametro 70 bd rt 4 4 4 800 bit Sec 9 6 9 600 bit Sec Baud rate IH g 19 200 bit Sec CH HH 28 800 bit Sec 3EMF 38 400 bit Sec 51 BF 57 600 bit Sec Formato 8 N 1 8 bit no parit 1 stop WORD READING max 20 word 0x03 0x04 Funzioni supportati SINGLE WORD WRITING 0x06 MULTIPLE WORDS WRITING max 20 word 0x10 Si riporta di seguito l elenco di tutti gli indirizzi disponibili e le funzioni supportate RO Read Only R W Read Write WO Write Only Modbus Descrizione Read Reset Address Only value 0 Tipo dispositivo RO EEPROM 1 Versione software RO EEPROM 5 Address slave R W EEPROM 6 Versione boot RO EEPROM 50 Indirizzamento automatico WO 51 Confronto codice impianto WO 500 Caricamento valori di default scrivere 9999 R W 0 510 Tempo salvataggio setpoint in eeprom 0 60 s R W 10 999 Processo sottoposto al filtro in visualizzazione RO Manuale d uso CN243 67 Modbus detenzione Read Reset Address Only value Processo gradi con decimo per sensori di temperatura 1000 ae l RO digit per sensori normalizzati 1001 Setpoint 1 R W EEPROM 1002 Setpoint 2 R W EEPROM 1003 Setpoint 3
33. tenths for temperature sensors Default 1750 LoL Lower Linear Input Range AN1 lower limit only for linear Example with input 4 20 mA this parameter takes value associated to 4 mA 999 bis 9999 digit Default 0 ATR243 User manual 31 10 11 12 13 uFL Upper Linear Input Range AN1 upper limit only for linear Example with input 4 20 mA this parameter takes value associated to 20 mA 999 bis 9999 digit Default 1000 LHEc Latch On Function Automatic setting of limits for linear inputs and potentiometers See paragraph 7 9 a5 Disabled Default Std Standard u USt Virtual zero stored uin Virtual zero initialized d 4n L Allows to surpass lower and upper limits if on input there are values out of 0 4 20mA or 0 10V n cHL Offset Calibration Value added subtracted to process visualization usually correcting the value of environment temperature 999 1000 digit for linear sensors and potentiometers 200 0 100 0 degrees tenths for temperature sensors Default 0 0 G cAL Gain Calibration Percentage value that is multiplied for the process value allows to calibrated the working point 99 9 100 0 Default 0 0 ex to correct the range from 0 1000 C showing 0 1010 C set the parameter to 1 0 Hck t Action type Regulation type HEHE Heating N O Default cool Cooling N C H n n5 Lock command above SPV Example command output disabled w
34. utilizzare cavo compensato e 19 morsetti adatti alla termocoppia utilizzata Compensati 1 JL i e Quando si usa il cavo schermato la schermatura va collegata a terra ad una sola estremit 52 CN243 Manuale d uso Shield Schermo Per termoresistenze PT100 NI100 e Peril collegamento a tre fili usare cavi della stessa sezione Per il collegamento a due fili cortocircuitare i morsetti 1 e di e Quando si usa il cavo schermato la schermatura va collegata a terra ad una sola estremit Selezionare il jumper interno JP3 come in figura ROSSO 3 BIANCO 2 A m ROSSO 1 OOLIN Ld 3 Per termoresistenze NTC PTC PT500 PT1000 e 4 potenziometri lineari z Quando si usa il cavo schermato la schermatura va 2 collegata a terra ad una sola estremit hielgrscienno P Py Fy 8 Per segnali normalizzati in corrente e tensione NENNEN Rispettare la polarit fe e Quando si usa il cavo schermato la schermatura va i collegata a terra ad una sola estremit a O Selezionare il jumper interno JP3 come in figura In mancanza della corretta selezione dei Jumper non saranno disponibili i 12 Vdc 30 mA sul morsetto numero 3 per l alimentazione del sensore 5 1 c Esempidi collegamento per ingressi Volt e mA 12V 30 mA LS 2 Per segnali normalizzati in tensione 0 10 V o
35. 0 3002 Second word display 1 ascii R W 0 3003 Third word display 1 ascii R W 0 3004 Fourth word display 1 ascii R W 0 3005 Fifth word display 1 ascii R W 0 3006 Sixth word display 1 ascii R W 0 3007 Seventh word display 1 ascii R W 0 3008 Eighth word display 1 ascii R W 0 3009 First word display 2 ascii R W 0 3010 Second word display 2 ascii R W 0 3011 Third word display 2 ascii R W 0 3012 Fourth word display 2 ascii R W 0 3013 Fifth word display 2 ascii R W 0 3014 Sixth word display 2 ascii R W 0 3015 Seventh word display 2 ascii R W 0 3016 Eight word display 2 ascii R W 0 Word LED BitO LED C1 Bit 1 LED C2 Bit2 LED A1 3017 Bit 3 LED A2 R W 0 Bit 4 LED A3 Bit 5 LED MAN Bit 6 LED TUN Bit 7 LED REM ATR243 User manual 27 Modbus Reset Addas Description Read Only UA Word keys write 1 to command keys 3018 X Bit0 R W 0 Bit 1 Bit 2 Word serial relay Bit 0 Relay Q1 a fite Relay Q2 ii g Bit 2 Relay Q3 3020 Word SSR serial 0 Off 1 On R W 0 3021 Word output 0 10 V serial 0 10000 R W 0 3022 Word output 4 20 mA serial 0 10000 R W 0 Relay state in case of off line only if controlled by serial 3023 Bit 0 Relay Q1 R W 0 Bit 1 Relay Q2 Bit 2 Relay Q3 Output state SSR 0 10 V 4 20 mA in case of 3024 off line only if controlled by serial R W 0 0 10000 3025 Serial process Setting parameter 54 it is possible R
36. 1 d i5 Disabled Default A AL Absolute alarm referring to process b AL Bandalarm H d AL Upper deviation alarm L d AL Lower deviation alarm A c AL Absolute alarm referring to command setpoint St AL Status alarm active in Run Start conL Cooling action L b A Status alarm load control Loop Break Alarm Example status of contactors SSR or heating elements A250 Alarm 2 State Output Alarm 2 output contact and intervention type n n 5 N O Start Normally open active at start Default n r 5 N C Start Normally closed active at start n n E N O Threshold Normally open active on reaching alarm n c E N C Threshold Normally closed active on reaching alarm HerE Alarm 2 Reset Alarm 2 contact reset type HrE Automatic reset Default rt Manual reset reset manual reset by keyboard flirE 5 Manual reset stored keeps relay status also after an eventual power failure H g5 E Alarm 2 State Error State of contact for alarm 2 output in case of error c n Open contact Default C C Closed contact 8 On activation the output is inhibited if the controller is in alarm mode Activates only if alarm condition reappers after that it was restored ATR243 User manual 35 35 36 37 38 39 40 Acid Alarm2Led State of OUT2 led corresponding to relative contact c n ON with open contact EE ON with closed contact Default AGHI Alarm 2 Hysteresis 999 9
37. 1 Switch two thresholds setpoint setpoint selection is done by an impulse on digital input jE 5 i Switch three thresholds setpoint by an impulse on digital input 4 5 Switch four thresholds setpoint by an impulse on digital input E rE5 Customized function P c 5 5 Pre programmed cycle see paragraph 7 7 Setpoints values can be modified any time pressing key Parameter 61 dik NB Settings on this parameter are available only if cont or Fr cH are selected on parameter 59 oF fin 5t 5k Start Stop operating on digital input the controller switches alternatively from start to stop rn n n Run N O Controller is in start only with closed input rn n c Run N C Controller is in start only with open input L c n a With closed input allows to lock the reading of sensors Lc n c With open input allows to lock the reading of sensors EunE Enables disables Tuning function if parameter 57 EunE is selected as 1H n ANA If parameter 60 Au fA is selected as En or En 5t controller switch from automatic to manual functioning ANA c If parameter 60 Ru AR is selected as En or En 5b CN243 works in automatic mode if input is open or in manual mode if input is closed NB The digital input functions are not available with sensors PT100 and NI100 on model CN243 R1F2 22 ATR243 User manual 7 12 Dual Action Heating Cooling CN243 is suitable also for systems requiring a combined heating cooling action
38. 1 00 coo F Cooling Fluid Type of refrigerant fluid for heating cooling P I D Hir Air Default D iL Oil Heo Water Ph Proportional Band Multiplier Proportional band multiplier Proportional band for cooling action is given by parameter 18 multiplied for this parameter 1 00 5 00 Default 1 00 oud b Overlap Dead Band Dead band combination for heating cooling action in heating cooling P I D mode dual action 20 0 50 096 of proportional band value Default 0 Negative indicates dead band value Positive means overlap co t c Cooling Cycle Time Cycle time for cooling output 1 300 seconds Default 10 c FLE Conversion Filter ADC Filter Number of input sensor readings to calculate the mean that defines process value NB When means increase control loop speed slows down do Disabled g 5 0 2 Samples Mean 3 5 0 3 Samples Mean Hd 5 1 4 Samples Mean 5 551 5 Samples Mean B 5 0 6 Samples Mean 1 5 4 7 Samples Mean B 5 0 8 Samples Mean g 5 1 9 Samples Mean 1 5 71 10 Samples Mean Default 1 5 f1 11 Samples Mean 25 7 12 Samples Mean 7 5 71 13 Samples Mean 1 5 0 14 Samples Mean 15 5 0 15 Samples Mean 38 ATR243 User manual 55 56 57 58 c Frn Conversion Frequency Sampling frequency of analogue digital converter NB Increasing the conversion speed will slow down reading stability example for fast transients as pressure it is advisable to increase samp
39. 10v Rispettare le polarit V A 1 Cp Manuale d uso CN243 53 SENSORE DIPRESSIONE PRESSURE TRANSMITTER Per segnali normalizzati in corrente 0 4 20 mA con sensore a tre fili 12V C 30 ma HE dl Rispettare le polarit A Uscita sensore 4 20mA af B Massa sensore C C Alimentazione sensore 12Vdc 30mA PRESSURE TRANSMITTER l uU ALIMENTAZIONE Per segnali normalizzati in corrente 0 4 20 mA con RNA Fs EXTERNAL sensore ad alimentazione esterna B li PIC 2 Rispettare le polarit 4 20mA A Uscita sensore VIA 1 5 B Massa sensore TERSSREBIFRESSIENE m PRESSURE TRANSMITTER Per segnali normalizzati in corrente 0 4 20 mA con CM ES sensore a due fili 30 mA po Am 4 20mA I Rispettare le polarit VIAL 1 45 LAN A Uscita sensore C Alimentazione sensore 12Vdc 30mA 5 1 d Ingresso seriale jac a TENES DN Comunicazione RS485 Modbus RTU 1 O a X Shield Schermo 5 1 e Uscita Rel Q1 p 8 Eu dm 7 t r6 Portata contatti 5 A 250 V per carichi resistivi NB vedi grafico nella pagina successiva 54 CN243 Manuale d uso 5 1 f Uscita Rel Q2 per CN243 R1F2 Portata contatti 5 A 250 V per carichi resistivi Per selezion
40. 2 c ad Q2 Q1 c 55r SSR Q1 c uhL O1 apri Q2 chiudi c4 00 4 20mA Q1 0 20 0 20mA Q1 cB 0 10V Q1 CN243 R1R2F3 COMANDO ALLARME 1 ALLARME 2 c nl Q1 Q2 SSR c ad Q2 Q1 SSR E SSR Q1 Q2 c uAL O1 apri Q2 chiudi SSR cH eu 4 20mA Q1 Q2 Uol 0 20 MA Q1 Q2 c Li ILI 0 10V Q1 Q2 CN243 R1R2R3F4C4 COMANDO ALLARME1 ALLARME2 ALLARME 3 c ol Q1 Q2 Q3 SSR c ad Q2 Q1 Q3 SSR ES SSR Q1 Q2 Q3 c uHL Q2 apri Q3 chiudi Q1 SSR eue 4 20 MA Q1 Q2 Q3 c 0 2cu 0 20 MA Q1 Q2 Q3 c Li IL 0 10V Q1 Q2 Q3 3 4 Solo su CN243 R1F2 non impostare se si utilizza la funzione di ritrasmissione del processo Non impostare mai se si utilizza la funzione di ritrasmissione del processo 72 CN243 Manuale d uso Sen Sensor Configurazione ingresso analogico selezione sensore Geir Tc K Default 260 C 1360 C Ec 5 TcS 40 C 1760 C Ec r TCR 40 C 1760 C Ec Tc J 200 C 1200 C PE Pt100 200 C 600 C PEI Pt100 200 C 140 C ni Ni100 60 C 180 C GEES NTC10K B3435K 40 125 C m c c NTCIOK OMEGA 40 150 C nec d NTC2252 OMEGA 40 150 C PEE PTCIK 50 C 150 C PES Pt500 100 C 600 C PEIF Pt1000 100 C 600 C Li IU 0 10 Volt eu 0 20 mA Heu 4 20mA UH 0 40 mVolt Pot Potenziometro max 6 KOhm Vedi paragrafo 7 9 Pot c Potenziometro max 150 KOhm Vedi paragrafo 7 9 ER T A con secondario 50 mA solo CN243 R1R2F3 R1R
41. 2R3F4C4 GE Decimal Point Seleziona il tipo di decimale visualizzato Default TEN 1 Decimale TERN 2 Decimali UGBDDOH 3Decimali Ln L5 Lower Limit Setpoint Limite inferiore impostabile per il setpoint 999 9999 digit gradi decimi per sensori di temperatura Default 0 uPLS Upper Limit Setpoint Limite superiore impostabile per il setpoint 999 9999 digit gradi decimi per sensori di temperatura Default 1750 LoL Lower Linear Input Limite inferiore range AN1 solo per normalizzati Es con ingresso 4 20 mA questo parametro assume il valore associato a 4 mA 999 bis 9999 digit Default 0 Manuale d uso CN243 73 7 uPL Upper Linear Input Limite superiore range AN1 solo per normalizzati Es con ingresso 4 20 mA questo parametro assume il valore associato a 20 MA 999 bis 9999 digit Default 1000 8 LHec Latch On Function Impostazione automatica dei limiti per ingressi normalizzati e potenziometri Vedi paragrafo 7 9 d5 Disabilitato Default Sed Standard ult Zero virtuale memorizzato uin Zero virtuale allo Start d 4n L Permette di superare i limiti inferiore e superiore se in ingresso ci sono valori esterni al 0 4 20mA o 0 10V 9 o cHl Offset Calibration Calibrazione offset Valore che si somma o sottrae al processo visualizzato es normalmente corregge il valore di temperatura ambiente 999 1000 digit per sensori normalizzati e potenziometri 200 0 100 0 gradi
42. 5 7 Media con 11 campionamenti 25 7 Media con 12 campionamenti 13 5 0 Media con 13 campionamenti 1 5 0 Media con 14 campionamenti 15 5 0 Media con 15 campionamenti J m tn EU Ln cn 55 c Frn Conversion Frequency Frequenza di campionamento del convertitore analogico digitale NB Aumentando la velocit di conversione diminuisce la stabilit di lettura es per transitori veloci come la pressione consigliabile aumentare la frequenza di campionamento Ee 242 Hz Massima velocit di conversione fe ar 123 Hz be H 62 Hz bli H 50 Hz 3g H 39 Hz jd cH 33 2Hz IB BH 19 6 Hz ITH 16 7 Hz Default Ideale per filtraggio disturbi 50 60 Hz I2SH 12 5Hz OH 10 Hz 8334 8 33 Hz B cSH 6 25 Hz HH 4 17 Hz Minima velocit di conversione Manuale d uso CN243 81 56 wFLt Visualization Filter Filtro in visualizzazione Rallenta l aggiornamento del valore di processo visualizzato sul display per facilitarne la lettura d 5 Disabilitato e filtro a forchetta massima velocita di aggiornamento display Default Filtro del primo ordine con filtro a forchetta Media con 2 campionamenti Media con 3 campionamenti Media con 4 campionamenti Media con 5 campionamenti Media con 6 campionamenti Media con 7 campionamenti Media con 8 campionamenti Media con 9 campionamenti Media con 10 campionamenti massimo rallentamento di aggiornamento display n Disabilitato senza filtro a forchetta F o Filtro del
43. 99 digit degrees tenths for temperature sensors Default 0 0 A cd Alarm 2 Delay 180 180 seconds Negative delay in alarm exit phase Positive delay in alarm entry phase Default 0 H g5 P Alarm 2 Setpoint Protection Alarm 2 set protection Does not allow operator to change value set Free Modification allowed Default Lack Protected HidE Protected and not visualized AL 3 Alarm3 Alarm 3 selection Alarm intervention is associated with AL3 See paragraph 11 a5 Disabled Default A AL Absolute alarm referring to process b AL Bandalarm H d AL Upper deviation alarm L d AL Lower deviation alarm A c AL Absolute alarm referring to command setpoint St AL Status alarm active in Run Start CoOL Cooling action See paragraph 12 L b R Status alarm load control Loop Break Alarm Example status of contactors SSR or heating elements H 35 n0 Alarm 3 State Output Alarm 3 output contact and intervention type n n 5 N O Start Normally open active at start Default n r 5 N C Start Normally closed active at start n n E N O Threshold Normally open active on reaching alarm n c E N C Threshold Normally closed active on reaching alarm Display of decimal point depends on setting of parameter 5E n and parameter d P On activation the output is inhibited if the controller is in alarm mode Activates only if alarm condition reappers after that it was restored 36
44. ALARM 1 ALARM 2 ALARM 3 c nl Q1 Q2 Q3 SSR c ac Q2 Q1 SSR SSR ear SSR Q1 Q2 Q3 c uHL Q2 opens Q3 closes Q1 SSR ede 4 20 MA Q1 Q2 Q3 c a 0 20 MA Q1 Q2 Q3 c Li IL 0 10 V Q1 Q2 Q3 3 4 Only on CN243 R1F2 do not select if process retransmission function is used Do not select if process retransmission function is used 30 ATR243 User manual Sen Sensor Analogue input configuration sensor selection Ec Tc K Default 260 C 1360 C Ec 5 Tc S 40 C 1760 C Ec r TCR 40 C 1760 C Ec Tc J 200 C 1200 C PE Pt100 200 C 600 C PEI Pt100 200 C 140 C ni NI100 60 C 180 C GEES NTC10K 83435K 40 125 C m c c NTCIOK OMEGA 40 150 C nec d NTC2252 OMEGA 40 150 C PEE PTCIK 50 C 150 C PES Pt500 100 C 600 C PEIF Pt1000 100 C 600 C Li IU 0 10 Volt 0 00 0 20mA Heu 4 20mA LUHU 0 40 mVolt Pot Potentiometer max 6 Kohm See paragraph 7 9 Pak Potentiometer max 150 Kohm See paragraph 7 9 LA 50 mA secondary Current transformer Only CN243 R1R2F3 CN243 R1R2R3F4C4 mur Decimal Point Select type of visualized decimal point Default TER 1 Decimal LH ad 2 Decimal oodd 3 Decimal Ln L5 Lower Limit Setpoint Lower limit selectable for setpoint 999 9999 digit degrees tenths for temperature sensors Default 0 uPLS Upper Limit Setpoint Upper limit selectable for setpoint 999 9999 digit degrees
45. Delay Tempo di ritardo per l intervento del Loop Break Alarm 00 00 60 00 mm ss Default 01 00 coo F Cooling Fluid Tipo di fluido refrigerante in modalit P I D caldo freddo Air Aria Default DIL Olio Heo Acqua Ph Proportional Band Multiplier Moltiplicatore di banda proporzionale La banda proporzionale per l azione freddo data dal valore del parametro 18 moltiplicato per questo valore 1 00 5 00 Default 1 00 oud b Overlap Dead Band Sovrapposizione Banda Morta In modalit P I D caldo freddo doppia azione definisce la combinazione di banda morta per l azione di riscaldamento e raffred damento 20 0 50 0 del valore di banda proporzionale Default 0 Negativo indica il valore di banda morta positivo significa la sovrapposizione co t c Cooling Cycle Time Tempo ciclo per uscita refrigerante 1 300 secondi Default 10 80 CN243 Manuale d uso 54 c Fit Conversion Filter Filtro ADC numero di letture del sensore di ingresso per il calcolo della media che definisce il valore del processo NB con l aumento delle medie rallenta la velocit del loop di controllo di 5 Disabilitato Z S A Media con 2 campionamenti 5 0 Media con 3 campionamenti 5 Media con 4 campionamenti 5 Media con 5 campionamenti 5 0 Media con 6 campionamenti 5 Media con 7 campionamenti 5 0 Media con 8 campionamenti 5 0 Media con 9 campionamenti 10 5 0 Media con 10 campionamenti Default 1
46. Disconnettere l alimentazione prima di qualsiasi intervento sulle connessioni elettriche o settaggi hardware L utilizzo manutenzione riservato a personale qualificato ed da intendersi esclusiva mente nel rispetto dei dati tecnici e delle condizioni ambientali dichiarate Non gettare le apparecchiature elettriche tra i rifiuti domestici Secondo la Direttiva Europea 2002 96 CE le apparecchiature elettriche esauste devono essere raccolte separatamente al fine di essere reimpiegate o riciclate in modo eco compatibile 2 Identificazione del modello La serie di regolatori CN243 prevede tre versioni facendo riferimento alla tabella seguente facile risalire al modello desiderato Modelli con alimentazione 24 230 Vac Vdc 15 50 60 Hz 5 5 VA CN243 R1F2 2 setpoint 2 Rel 5 A oppure 1 Rel 1 Ssr V mA CN243 R1R2F3 3 setpoint 2 Rere 5 A 1 Ssr V mA RS485 trasformatore amperometrico 4 setpoint 3 Rel 5 A 1 Ssr V mA trasformatore amperometrico CN243 R1R2R3F4C4 Modelli con ingresso per T A per funzione Loop Break Alarm 48 CN243 Manuale d uso 3 Dati tecnici 3 1 Visualizzatori Caratteristiche generali 4 display 0 40 pollici 4 display 0 30 pollici Temperatura Temperatura funzionamento 0 45 C di esercizio Umidita 35 95 uR Protezione IP65 su frontale con guarnizione IP20 cu stodia e morsetti Materiale PC ABS UL94VO autoestinguente Peso 165 g 20ABC 185 g
47. Normalmente visualizza il processo In fase di configurazione 1 ist ui tue visualizza il parametro in inserimento Iu Normalmente visualizza i setpoint In fase di configurazione visualizza il valore del parametro in inserimento 6 2 Significato delle spie di stato Led Si accendono quando l uscita comando attiva C1 con comando 3 C1 C2 rel SSR mA Volt o C1 apri e C2 chiudi nel caso di comando valvola motorizzata 4 Al A2 A3 Si accendono quando l allarme corrispondente attivo 5 MAN Si accende all attivazione della funzione Manuale Si accende quando il regolatore sta eseguendo un ciclo di 6 TUN AutoTuning 7 REM Si accende quando il regolatore comunica via seriale 58 CN243 Manuale d uso 6 3 Tasti Incrementa il setpoint principale e In fase di configurazione consente di scorrere i parametri Insieme nails al tasto li modifica Premuto dopo il tasto incrementa i setpoint di allarme Decrementa il setpoint principale In fase di configurazione consente di scorrere i parametri Insieme al tasto li modifica Premuto dopo il tasto decrementa i setpoint di allarme Permette di visualizzare i setpoint di allarme e di entrare nella 10 SET funzione di lancio del Tuning Permette di variare i parametri di configurazione 7 Funzioni del regolatore 71 Modifica valore setpoint principale e setpoint di allarme Il valore dei setpoint pu essere modificato da tastiera come segue
48. UNING vies cereus navn 16 73 Nilla 16 Z4 Automatic 1 IAIIAG casa 17 LS Sla 17 7 6 Automatic Manual Regulation for Output Control esses 17 57 Pre Programmed CVEIB rana 18 48 CN Config Module 1ODtIOHOl usassomsdnn uinea iod aed dune dini daas u 19 7 9 Latch on TUELION CERERE RIA 20 7 10 Loop Break Alarm On Current Trasformoet usu ict tesi tees adn aab RES e disce 20 7 11 Digital Input FUNCTIONS de 22 7 12 Dual Action Heating Cooling ssa ai ddnde oa ds tob haa n CIS RC tei t 23 8 Serial Communication RCLRP M 24 CI RATA 29 9 1 die 29 10 Table OF Configuration PArAmietehi lecita 30 11 PTAC CR OILS ance htt apod eni bai Ihr artus ait 42 12 Table of Anomaly SIQUIGN DEM 45 13 Configuration EASY UP cele 46 ATR243 User manual 3 Sommario I NOVO CI SI CWI O ZI aaa 52 2 Identificazione del Oda 52 gt PIRO 53 3414 aeree ili 53 3 2 Caratteristiche Hodder 53 3 3 COMM 54 4 Dimensioni ed installaziOne sessssesssssssosssssseeresssseessssssseeesssecesoonssseeessseeerossssereosssseerossssereoessseres 54 4 1 Montaggio a pannello saciacisiediad i e CUR He CUN Ku CUN Re OU Mn RM A D 55 42 Estrazione dell elettronica cena 55 5 Collegamenti elettrici ea 56 5 1 Sch madicollegamentO sala 56 6 Funzione del VISUGIIZZATONetasli ci lai 62 6 1 Indicatori numerici DIR 62 6 2 Significato delle spie di stato eil 62 03 lana 63 7 FURONO l
49. W 0 to make averages on the remote process 4001 Parameter 1 RAW EEPROM 4002 Parameter 2 R W EEPROM 4072 Parameter 72 R W EEPROM Ifval e is 0 control is disabled If different from 0 it is the max time that can elapse between two pollings before the controller goes off line If it goes off line the controller returns to Stop mode control output is disabled but the alarms are active By writing 1 on this word the effects of the writing are cancelled on all the Modbus addresses from 3001 to 3022 Control therefore returns to the controller Parameters modified using serial address 4001 to 4072 will be stored on eeprom only after 10 since last writing of one parameter 28 ATR243 User manual 9 Enter configuration For configuration parameters see paragraph 10 Press for 3 seconds Display Display 1 shows 2 000 with the 1st digit flashing while display 2 shows FASS Do 2 Dor Changes flashing digit and move to the next one using key Enter password i234 to confirm Display 1 shows the first parameter and display 2 shows the value a XJo Y Slide up down through parameters l or Increase or decrease displayed value by keep pressing and after an arrow key Enter new data which will be saved on releasing the keys To change another parameter return to point 4 s UY simultaneously End of configuration parameter change The con
50. YEAR C C TE OMEGA WARRANTY User s Guide Shop online at omega com e mail info omega com For latest product manuals www omegamanual info CN243 SERIES Controllers OMEGA omega com info omega com Servicing North America U S A Omega Engineering Inc One Omega Drive P O Box 4047 Stamford CT 06907 0047 USA Toll Free 1 800 826 6342 USA amp Canada only Customer Service 1 800 622 2378 USA amp Canada only Engineering Service 1 800 872 9436 USA amp Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide The information contained in this document is believed to be correct but OMEGA accepts no liability for any errors it contains and reserves the right to alter specifications without notice Table of contents I Safety guide lihe aseo auno Odd aique Eum ui gees aeons dione ened ai RR NR NE 5 2 Modelidentification nana 5 3 JEBnHIEOUDUIE bo Enia nia ala ile dia ile ttu 5 Bl Rd 5 3 2 IONICO 6 3 3 edilizi 6 4 Dimensions and illa 7 4 1 Panel ASSEmiply imitano 8 4 2 Electronics ReMOvadl ssssssssssessssoerssssesssssssoeesssseeeesossseerossseeessossreeesssseseeoossneeressseeeeoossssreessseeeessss 8 SCR 9 51 Molde 9 6 Display and Key FUBELOS cha 15 6 1 Numeric Indicators DPL 15 6 2 Meaning of Status lobi 15 03 Micia 16 FCI 16 71 Modifying Main Setpoint and Alarm Setpoint Values sees 16 IZ PUTO T
51. a ingresso T A 13 Dipende dall impostazione del parametro 5 E n e del parametro d P Manuale d uso CN243 83 66 67 68 69 70 71 dELr Degree Selezione tipo gradi Be Gradi Centigradi Default OF Gradi Fahrenheit rEtr Retransmission Ritrasmissione per uscita 0 10 V o 4 20 mA Selezionare Jumper JP5 JP7 e JP9 Parametri 68 e 69 definiscono il limite inf e sup della scala di funzionamento di 5 Disabilitato uo FP Ritrasmette il processo in Volt MA F Ritrasmette il processo in mA uo c Ritrasmette il setpoint di comando in Volt HH c Ritrasmette il setpoint di comando in mA un n F Volt uscita percentuale comando ilA o F mA uscita percentuale comando un H Volt setpoint di allarme 1 HR R mA setpoint di allarme 1 un H Volt setpoint di allarme 2 NARA mA setpoint di allarme 2 uo L A Volt T A HR E RH MATA Lol r Lower Limit Retransmission Limite inferiore range ritrasmissione uscita Volt mA 999 9999 digit gradi decimi per sensori di temperatura Default 0 uPL r Upper Limit Retransmission Limite superiore range ritrasmissione uscita Volt mA 999 9999 digit gradi decimi per sensori di temperatura Default 1000 bd rt Baud Rate Seleziona il baud rate per la comunicazione seriale ie 4 800 Bit s 4 6 F 9 600 Bit s cr 19 200 Bit s Default cH H 28 800 Bit s 384r 39 400 Bit s 5 BF 57 600 Bit s SL Ad Slave Address Seleziona l indirizzo dello slav
52. active at start n n E N O Threshold Normally open active on reaching alarm n c N C Threshold Normally closed active on reaching alarm HirE Alarm 1 Reset Alarm 1 contact reset type Are Automatic reset Default Heb Manual reset ser firE 5S Manual reset stored keeps relay status also after an eventual power failure H 5 E Alarm 1 State Reset State of contact for alarm 1 output in case of error c n Open contact Default C E Closed contact A iLd Alarm 1 Led Defines the state of OUT2 led corresponding to the relative contact c n ON with open contact EE ON with closed contact Default H tHY Alarm 1 Hysteresis 999 4 999 digit degrees tenths for temperature sensors Default 0 0 6 7 34 On activation the output is inhibited if the controller is in alarm mode Activates only if alarm condition reappers after that it was restored Display of decimal point depends on setting of parameter 5 E n and parameter d P ATR243 User manual 29 30 31 32 33 34 H LdE Alarm 1 Delay 180 180 seconds Negative delay in alarm output phase Positive delay in alarm entry phase Default 0 H 5P Alarm 1 Setpoint Protection Alarm 1 set protection Does not allow user to modify setpoint Pree Modification allowed Default Locr Protected HidE Protected and not visualized HL amp 8 Alarm2 Alarm 2 selection Alarm intervention is related to AL2 See paragraph 1
53. ailer can reduce stock needs The series includes also a model with serial communication RS485 Modbus RTU and with a loading control function via current transformer The possibility to repeat parametri zation is simplified by the CN Config Module with internal battery that do not require power supply for the controller 1 Safety guide lines Read carefully the safety guidelines and programming instructions contained in this manual before using connecting the device Disconnect power supply before proceeding to hardware settings or electrical wirings Only qualified personnel should be allowed to use the device and or service it and in accordance to technical data and environmental conditions listed in this manual Do not dispose electric tools together with household waste material In observance European Directive 2002 96 EC on waste electrical and electronic equipment and its implementation in accordance with national law electric tools that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility 2 Model identification CN243 series includes three versions Looking at the table here below it is possible to find the required model Power supply 24 230 Vac Vdc 15 50 60 Hz 5 5 VA CN243 R1F2 2 relays 5 A or 1 relay 1 Ssr V mA CN243 R1R2F3 2 relays 5 A 1 Ssr V mA RS485 current transformer CN243 RIR2R3F4C4 3 relays 5 A 1 Ssr V mA current transfor
54. amming LED VERDE programmazione eseguita Green Light done NB it is not possible to transfer parameters to a device with different code red LED is ON Updating CN Config Module To update the CN Config Module values follow the procedure described on first mode setting display 2 to so as not to load the parameters on controller Enter configuration and change at least one parameter Exit configuration Changes are stored automatically Ifon activation the controller does not display memo it means no data have been saved on the CN Config Module but it is possible to update values ATR243 User manual 19 79 Latch on function For use with input Fat potentiometer 6 KO and Pat e potentiometer 150 KO and with linear input 0 10 V 0 40 mV 0 4 20 mA it is possible to associate start value of the scale parameter 6 LoL to the minimum position of the sensor and value of end scale parameter 7 uPL to the maximum position of the sensor parameter 8 HE c configured as Std It is also possible to fix the point in which the controller will display 0 however keeping the scale range between LoL and uFL using the virtual zero option by setting u DSE or u D in in parameter 8 LH Ec If you set u U in the virtual zero will reset after each activation of the tool if you set u OSE the virtual zero remains fixed once tuned Selecting d n L dynamic limits it is possible to surpass lowe
55. are Q2 come uscita rel verificare che non siano inseriti i jumper JP5 e JP7 NB vedi grafico nella pagina successiva Connettere un carico senza togliere i Jumper danneggia il regolatore 5 1 g Uscita Rel Q2 per CN243 R1R2F3 e CN243 R1R2R3F4C4 J 14 _ Portata contatti 5 A 250 V per carichi resistivi Q2 jan 13 NB vedi grafico nella pagina successiva 5 1 h Uscita Rel Q3 su CN243 R1R2R3F4C4 12 ___ Portata contatti 5 A 250 V per carichi resistivi Q3 d 11 NB vedi grafico qui sotto 210 Electrical endurance 250V osta load Q1 Q2 03 M 2 10 5 A 250 Vac carico resistivo 105 operazioni 20 2 A 250 Vac cosg 0 3 105 operazioni 104 0 2 3 4 5 6 7 50324 A Switching current A Manuale d uso CN243 55 5 1 i Uscita SSR Uscita comando SSR portata 12 V 30 mA min 10 5 V DO Inserire JP5 e JP7 e selezionare JP9 come in figura per utilizzare l uscita SSR mA Uscita continua in mA configurabile da parametri come comando parametro c aut o ritrasmissione del processo setpoint parametro rEtr Inserire JP5 e JP7 e selezionare JP9 come in figura per utilizzare l uscita continua in mA Jumpers forniti all interno della confezione
56. armi mantenuto anche quando non circola corrente sul carico Impostando sul parametro 48 i b5 R E il valore 0 possibile visualizzare la corrente assorbita senza mai generare il Loop Break Alarm 711 Funzioni da Ingresso digitale Il CN243 integra alcune funzionalit relative all ingresso digitale che pu essere abilitato utilizzando i parametri 59 oF flo e 61 dLE e Parametro 59 a fla NB Utilizzando le seguenti impostazioni il parametro 61 dit i viene ignorato gb 5 Cambio setpoint a due soglie con contatto aperto il CN243 regola su SET1 con contatto chiuso regola su SET2 EE 5 Cambio setpoint a due soglie la selezione del punto di lavoro viene fatta agendo con un impulso sull ingresso digitale jE 5 Cambio setpoint a tre soglie con impulso sull ingresso digitale HE 5 Cambio setpoint a quattro soglie con impulso sull ingresso digitale E rE5 Funzione personalizzata P c 5 5 Ciclo pre programmato Vedi paragrafo 7 7 vari setpoint possono essere impostati durante il funzionamento premendo str 64 CN243 Manuale d uso e Parametro 61 dE NB Le impostazioni su questo parametro sono considerate solo impostando cont oppure Pr c4 sul parametro 59 af fin 5E 5E Start Stop agendo sull ingresso digitale il regolatore passa alternativamente da start a stop rn n n Run N O Il regolatore in start solamente con ingresso chiuso rn n c Run N C Il regolatore in start solam
57. as funzionamento freddo par 311 Hct RITI selezionato caa e valore di isteresi minore di 0 par 28 A LHY lt 0 Off Off Alarm output 11 b Allarme assoluto o allarme di soglia riferito al setpoint di comando selezione A c AL 4 Comand Spv Bettis Allarme assoluto riferito al set di comando IMPO con regolatore in funzionamento caldo par 11 l T HcE E selezionando HERE e valore di isteresi 1 3 maggiore di 0 par 28 A HH gt 0 l Il set di comando pu essere variato con la Re AMA pressione dei tasti freccia da frontale o con On comandi su porta seriale RS485 of EMME OF 1 C Allarme di Banda selezione h AL Alarm Spv Hysteresis Comand Spy arameter LH3 gt 0 I sana Allarme di banda valore di isteresi maggiore di arm Spv am 0 par 28 A HH gt 0 x Time On On On Eo of MM o 0v Hysteresis arameter LAY 0 Pv Alarm Spv Do e RO Allarme di banda valore di isteresi minore di 0 ZX x Hysteresis EIA Rowe rameter par 28A 1H4 lt 0 ALH lt 0 Time On On On Alarm Mot o eee L esempio riferito all allarme 1 la funzione abilitabile anche per gli allarmi 2 e 3 sui modelli che li prevedono 86 CN243 Manuale d uso 11 d LON Alarm Spv 7 j gt E Hysteresis arameter LHI gt 0 Time On On Off mi Alarm output Comand Spv Allarme deviazione superiore sele
58. ativo dallo start Default n c 5 N C Start Normalmente chiuso operativo dallo start n n t N O Threshold Normalmente aperto operativo al raggiungimento dell allarme n r E N C Threshold Normalmente chiuso operativo al raggiungimento dell allarme Dipende dall impostazione del parametro 5 E n e del parametro d P All accensione l uscita inibita se lo strumento in condizione di allarme Si attiva solo quando rientrato dalla condizione d allarme questa si ripresenta Manuale d uso CN243 77 33 34 35 36 37 38 39 AREE Alarm 2 Reset Tipo di riarmo del contatto dell allarme 2 Are Reset automatico Default rt Reset manuale riarmo reset manuale da tastiera firE S Reset manuale memorizzato mantiene lo stato del rel anche dopo un eventuale mancanza di alimentazione H g5 E Alarm 2 State Error Stato del contatto per l uscita di allarme 2 in caso di errore ta Contatto aperto Default EE Contatto chiuso Acid Alarm 2 Led Definisce lo stato del led OUT2 in corrispondenza del relativo contatto c n Acceso a contatto aperto C C Acceso a contatto chiuso Default AZH4 Alarm 2 Hysteresis 999 999 digit gradi decimi per sensori di temperatura Default 0 0 A2d E Alarm 2 Delay 180 180 secondi Negativo ritardo in fase di uscita dall allarme Positivo ritardo in fase di entrata dell allarme Default 0 H g5 P Alarm 2 Setpoint Protection Non conse
59. cquisition Systems A Plug in Cards for Apple IBM amp Compatibles IA Data Logging Systems lA Recorders Printers amp Plotters HEATERS I Heating Cable DA Cartridge amp Strip Heaters IA Immersion amp Band Heaters WA Flexible Heaters IA Laboratory Heaters ENVIRONMENTAL MONITORING AND CONTROL IA Metering amp Control Instrumentation WA Refractometers IA Pumps amp Tubing lA Air Soil amp Water Monitors LA Industrial Water amp Wastewater Treatment IA pH Conductivity amp Dissolved Oxygen Instruments M5303 1015
60. decimi per sensori di temperatura Default 0 0 10 G cAL Gain Calibration Calibrazione guadagno Al1 Valore che si moltiplica al processo per eseguire calibrazione sul punto di lavoro 99 9 100 0 Default 0 0 es per correggere la scala di lavoro da 0 1000 C che visualizza 0 1010 C fissare il parametro a 1 0 11 Act t Action type HEAE Caldo N A Default conL Freddo N C H n n5 Blocca comando sopra SPV Es uscita di comando disabilitata al raggiungi mento del setpoint anche con valore di P I D diverso da zero 12 c rE Command Reset Tipo di riarmo del contatto di comando sempre automatico in funzionamento P I D HrE Riarmo automatico Default Hr Reset manuale firE S Reset manuale memorizzato mantiene lo stato del rel anche dopo un eventuale mancanza di alimentazione 13 c amp E Command State Error Stato del contatto per l uscita di comando in caso di errore co Contatto aperto Default C C Contatto chiuso 74 CN243 Manuale d uso 14 15 16 17 18 19 20 21 22 c Ld Command Led Definisce lo stato del led OUT1 in corrispondenza del relativo contatto c n Acceso a contatto aperto C E Acceso a contatto chiuso Default c H4 Command Hysteresis Isteresi in ON OFF o banda morta in P I D 999 999 digit gradi decimi per sensori di temperatura Default 0 0 c dE Command Delay Ritardo comando solo in funzionamento ON OFF In caso di servo valvola fun
61. e Derivative Time Cycle Time Output Power Limit Alarm 1 Alarm 1 State Output Alarm 1 Reset Alarm 1 State Reset Alarm 1 Led Alarm 1 Hysteresis Alarm 1 Delay Alarm 1 Setpoint Protection Alarm 2 Alarm 2 State Output Alarm 2 Reset Alarm 2 State Error Alarm 2 Led Alarm 2 Hysteresis Alarm 2 Delay Alarm 2 Setpoint Protection Alarm 3 Alarm 3 State Output Alarm 3 Reset Alarm 3 State Error Alarm 3 LED 74 75 75 75 75 75 75 76 76 76 76 76 76 76 77 77 77 77 77 77 77 77 78 78 78 78 78 79 79 79 79 79 80 80 80 80 80 80 80 81 81 81 81 Manuale d uso CN243 89 44 AJH 45 Aaoe 46 H35 P 47 EH 48 1 b ALE 49 Lb Hd 50 can F 51 Phi 52 Oud 53 co 54 c FLE 55 crm 56 u FLE 57 tunt 58 5 dtu 59 nHlin 60 Huh 61 dit 62 LrHd 63 MAE 64 uH c P 65 welt 66 Ebr 67 rtr 68 LoL r 69 uPi r 70 bd rt 71 b5L Hd 72 5E gE 73 Lae Alarm 3 Hysteresis Alarm 3 Delay Alarm 3 Setpoint Protection Amperometric Transformer Loop Break Alarm Threshold Loop Break Alarm Delay Cooling Fluid Proportional Band Multiplier Overlap Dead Band Cooling Cycle Time Conversion Filter Conversion Frequency Visualization Filter Tune Setpoint Deviation Tune Operating Mode Automatic Manual Digital Input Gradient Maintenance Time User Menu Cycle Programmed Visualization Type Degree Retransmission Lower Limit Retransmission Upper Limit Retransmission Baud Rate
62. e autotuning starts when Soft Start time is finished while if parameter 57 Eun is set on An the autotuning can be started only when Soft Start finishes 7 6 Automatic Manual Regulation for Output Control This function allows to select automatic functioning or manual command of the output percentage With parameter 60 Au 71A the operator can select two methods 1 First selection En Pressing key display 1 shows F while display 2 shows Hut a Pressing key display shows An itis now possible to change the output percentage using and Y To return to automatic mode using the same procedure select Auto on display 2 led MAN switches off and functioning returns to automatic mode 2 Second selection En5t enables the same functioning but with two important variants e If there isa temporary power failure or after switch off the manual functioning as well as the previous output percentage value will be maintained at restarting e If the sensor breaks during automatic functioning the controller moves to manual mode while maintaining the output percentage command unchanged as generated by the P I D immediately before breakage ATR243 User manual 17 7 7 Pre Programmed Cycle The pre programmed cycle function activates by setting Pr cH or Pc 55 on parameter 59 oPfla First selection Pr c the controller reaches setpoint basing on t Hold the gradient set on parameter 62 GrAd then Setpoint 2 aisi it reac
63. e il Tuning lasciando invariati i valori PID premere il tasto finch il display 1 non visualizza la scritta tun e il display 2 visualizza on Premendo KR il display 2 visualizza aFF il led TUN si spegne e la procedura termina 7 5 Soft Start All accensione il regolatore per raggiungere il setpoint segue un gradiente di salita impostato in Unit es Grado Ora Impostare sul parametro 62 GrAd il valore di incremento desiderato in Unit Ora alla successiva accensione lo strumento eseguir la funzione Soft Start Se il parametro 59 aF fla impostato su cant e il parametro 63 MA L diverso da 0 dopo l accensione trascorso il tempo impostato sul parametro 63 il setpoint non segue pi il gradiente ma si porta alla massima potenza verso il setpoint finale L autotuning non funziona mai quando solo il par GrFd diverso da 0 Se il parametro 63 H E 1 diverso da 0 e il parametro 57 tun impostato su Auto l autotuning parte allo scadere del tempo di Soft Start mentre se il parametro 57 En E impostato MAn la funzione pu essere lanciata solamente allo scadere del Soft Start 7 6 Regolazione automatico manuale per controllo uscita Questa funzione permette di passare dal funzionamento automatico al comando manuale della percentuale dell uscita Con il parametro 60 Au A possibile selezionare due modalit 1 La prima selezione En permette di abilitare con il tasto la scritta P sul display 1 mentre sul
64. e istantanea Ampere R W 0 1024 Stato ingresso digitale R W 0 Tuning sincronizzato per multizona 0 Tuning OFF Funzionamento normale del regolatore 1 Uscita comando OFF 1025 2 Uscita comando ON R W 0 3 Start Tuning 4 Fine Tuning e comando OFF Portare la word 1025 al valore 0 Processo sottoposto al filtro in visualizzazione e alla 1099 RO selezione del punto decimale 1100 Processo con selezione del punto decimale RO 1101 Setpoint 1 con selezione del punto decimale R W EEPROM 1102 Setpoint 2 con selezione del punto decimale R W EEPROM 1103 Setpoint 3 con selezione del punto decimale R W EEPROM 1104 Setpoint 4 con selezione del punto decimale R W EEPROM 1105 Allarme 1 con selezione del punto decimale R W EEPROM 1106 Allarme 2 con selezione del punto decimale R W___EEPROM 1107 Allarme 3 con selezione del punto decimale R W EEPROM 1108 Setpoint gradiente con sel del punto decimale RO EEPROM 1109 Percentuale uscita caldo 0 1000 R W 0 1110 Percentuale uscita caldo 0 100 RO 0 1111 Percentuale uscita freddo 0 1000 RO 0 1112 Percentuale uscita freddo 0 100 RO 0 2001 Parametro 1 RAW EEPROM 2002 Parametro 2 R W EEPROM 2072 Parametro 72 R W EEPROM 3000 Disabilitazione controllo macchina da seriale RO 0 3001 Prima word display 1 ascii R W 0 3002 Seconda word display 1 ascii R W 0 3003 Terza word display 1 ascii R W
65. e l uscita di regolazione e segnala il tipo di anomalia riscontrata Per esempio il regolatore segnaler la rottura di un eventuale termocoppia collegata visualizzando 05 lampeggiante sul display 1 e una breve descrizione Prb sonda sul display 2 Per le altre segnalazioni vedere la tabella sottostante Causa Cosa fare E 01 Errore in programmazione cella CuG E EEPROM Contattare Assistenza Guasto sensore temperatura E 02 giunto freddo o temperatura 545E ambiente al di fuori dei limiti Contattare Assistenza ammessi Dati di configurazione errati a Possibile perdita della tarature Fia dello strumento l E 05 Termocoppia aperta o Controllare il collegamento con Prb temperatura fuori limite le sonde e la loro integrit ae Tarature mancanti Contattare Assistenza 5HS E Note Aggiornamenti 88 CN243 Manuale d uso Tabella delle configurazioni dei parametri COIN AD UW B W N Louk Sen dF LoS uL LOL uPL i LHEc 9 n cH 10 L cH 11 fTebkE 12 c DD MT rE Ji Ld H3 ge IF Command Output Sensor Decimal Point Lower Limit Setpoint Upper Limit Setpoint Lower Linear Input Upper Linear Input Latch On Function Offset Calibration Gain Calibration Action type Command Reset Command State Error Command Led Command Hysteresis Command Delay Command Setpoint Protection Proportional Band Integral Tim
66. e perla comunicazione seriale 1 254 Default 254 14 La visualizzazione del punto decimale dipende dall impostazione del parametro 5E n e del parametro gr 84 CN243 Manuale d uso 72 5E dE Serial Delay Seleziona il ritardo seriale 0 100millisecondi Default 20 73 LL o P Lower Limit Output Percentage Seleziona il valore minimo per la percentuale dell uscita di comando 0 100 Default 0 Es con c nut selezionato 0 10 V e impostazione su L L oF al 10 l uscita di comando pu variare da un minimo di 1 V al massimo di 10 V 11 Modid intervento allarme 11 a Allarme assoluto o allarme di soglia selezione A AL Alarm Spv ERAN Hysteresis Allarme assoluto con regolatore in i paco funzionamento caldo par 11 Actt i selezionato HEAL e valore di isteresi maggiore ee di 0 par 28 AL LHY gt 0 Alarm output 5 dione j P AHI lt 0 7 Em Di Alarmspv Allarme assoluto con regolatore in gt funzionamento caldo par 11 Hct P selezionando HEHE e valore di isteresi minore Time di 0 par 28 A LHY lt 0 2 2 Alarm of RN o ES cv Time Fy Hysteresis N aramete Allarme assoluto con regolatore in 3 ds 2s funzionamento freddo par 11 Hct F AlarmSpv selezionando HEAL e valore di isteresi d maggiore di 0 par 28 A LHH gt 0 On On Alarm or MEN or EN 55 Manuale d uso CN243 85 Time Alam Spv Allarme assoluto con regolatore in negr
67. egrees for temperature sensors Es Integral Time Process inertia in seconds 0 0 999 9 seconds 0 integral disabled Default 0 0 E d Derivative Time Normally of integral time 0 0 999 9 seconds 0 derivative disabled Default 0 0 EG Cycle Time Cycle time for P I D on remote control switch 10 15 sec for P l D on SSR 1 sec or servo time value declared by servo motor manufacturer 1 300 seconds Default 10 ool Output Power Limit Select max value for command output percentage 0 100 Default 100 Es with c nut selected as 0 10 V and a FaL as 90 command output can modulate from a min of 0 V to a max of 9 V 5 Display of decimal point depends on setting of parameter 5 En and parameter d P ATR243 User manual 33 23 24 25 26 27 28 AL I Alarm 1 Alarm 1 selection Alarm intervention is related to AL1 See paragraph 11 di 5 Disabled Default A AL Absolute alarm referring to process b AL Bandalarm H d AL Upper deviation alarm L d AL Lower deviation alarm A c AL Absolute alarm referring to command setpoint SERL Status alarm active in Run Start cool Cooling action L b R Status alarm load control Loop Break Alarm Example status of contactors SSR or heating elements AiS Alarm 1 State Output Alarm 1 output contact and intervention type n n 5 N O Start Normally open active at start Default n r 5 N C Start Normally closed
68. elezione allarme 1 L intervento dell allarme associato a AL1 Vedi paragrafo 11 di 5 Disabilitato Default A AL Assoluto soglia riferito al processo b AL Allarme di banda H d FL Allarme di deviazione superiore L d AL Allarme di deviazione inferiore A c AL Assoluto soglia riferito al setpoint di comando SEAL Allarme di stato attivo in Run Start cool Azione freddo cooling Vedi paragrafo 7 12 L b H Allarme di stato controllo carico Loop Break Alarm Es controlla lo stato dei contattori SSR o delle resistenze AISO Alarm 1 State Output Contatto uscita allarme 1 e tipo intervento n n 5 N O Start Normalmente aperto operativo dallo start Default n c 5 N C Start Normalmente chiuso operativo dallo start n n t N O Threshold Normalmente aperto operativo al raggiungimento dell allarme n r E N C Threshold Normalmente chiuso operativo al raggiungimento dell allarme Aire Alarm 1 Reset Tipo di reset del contatto dell allarme 1 Are Automatic Reset Default ire Reset manuale riarmo reset manuale da tastiera firE S Reset Manuale memorizzato mantiene lo stato del rel anche dopo un eventuale mancanza di alimentazione H 5 E Alarm 1 State Reset Stato del contatto per l uscita di allarme 1 in caso di errore Ea Contatto aperto Default C C Contatto chiuso A iLd Alarm 1 Led Definisce lo stato del led OUT2 in corrispondenza del relativo contatto c n Acceso a contatto ap
69. emuto prima epoiun tasti Per variare un altro tasto freccia parametro tornare al punto 4 OK CY 6 contemporanea mente Fine variazione parametri di configurazione Il regolatore esce dalla programmazione 9 1 Caricamento valori di default Questa procedura permette di ripristinare le impostazioni di fabbrica dello strumento Premere SET per 3 secondi Effetto Eseguire Su display 1 compare 0000 con la 1 cifra lampeggiante mentre sul display 2 compare PASS Si modifica la cifra 2 o lampeggiante si passa alla Inserire la password 9999 successiva con il tasto str 3 SET Lo strumento carica le Spegnere e riaccendere lo impostazioni di fabbrica strumento per conferma Manuale d uso CN243 71 10 Tabella parametri di configurazione L elenco dei parametri sotto riportato completo alcuni di questi non appariranno sui modelli che non dispongono delle relative risorse Hardware 1 Louk Command Output selezione tipo uscita di comando vedi tabelle sottostanti c nl Default necessario per utilizzo funzione di ritrasmissione di processo e set con uscita Volt mA c od Comando su uscita rel Q2 c55r X Comandoin tensione per SSR c uAL Comando servo valvole a loop aperto cHe amp l Comando con segnale 4 20 mA cle Comando con segnale 0 20 mA c l Comando con segnale 0 10 V CN243 R1F2 COMANDO ALLARME 1 c nl Q1 Q
70. ente con ingresso aperto L c n n Con ingresso chiuso blocca la lettura delle sonde Lc n c Con ingresso aperto blocca la lettura delle sonde EunE Abilita disabilita il Tuning se il parametro 57 Eun E impostato su MAn H HR 1 Se par 60 Ru lH impostato su En o En 5E agendo sull ingresso il regolatore passa alternativamente da regolazione automatica a regolazione manuale H HB e Se par 60 Au A impostato su En o En St Il CN243 regola in automatico con ingresso aperto e in manuale con ingresso chiuso NB le funzioni da ingresso digitale NON sono disponibili con sonde di tipo resistivo sul modello CN243 R1F2 712 Funzionamento in doppia azione caldo freddo II CN243 adatto alla regolazione anche su impianti che prevedano un azione combinata caldo freddo L uscita di comando deve essere configurata in P I D caldo Ack t HERE e Ph maggiore di 0 e uno degli allarmi AL AL c oppure RL 3 deve essere configurato come rant L uscita di comando va collegata all attuatore responsabile dell azione caldo l allarme comander invece l azione refrigerante parametri da configurare per il P I D caldo sono Act t HERE Tipo azione uscita di comando Caldo F b Banda proporzionale azione caldo E Tempo integrale azione caldo ed azione freddo E d Tempo derivativo azione caldo ed azione freddo E c Tempo di ciclo azione caldo parametri da configurare per il P I D freddo sono azione associata
71. er Limit Retransmission Output V mA retransmission upper limit range 999 9999 digit degrees tenths for temperature sensors Default 1000 14 The display of the decimal point depends on the setting of parameter 5En and the parameter d P ATR243 User manual 41 70 bd rt Baud Rate Select baud rate for serial communication 4B 4 800 Bit s gb F 9 600 Bit s PF 19 200 Bit s Default ear 28 800 Bit s 38HF 39 400 Bit s Si bF 57 600 Bit s 71 5LHd Slave Address Select slave address for serial communication 1 254 Default 254 72 5SE dE Serial Delay Select serial delay 0 100 milliseconds Default 20 73 LL o P Lower Limit Output Percentage Selects min value for command output percentage 0 10096 Default 096 Ex with c n ut selected as 0 10 V and Li a P set at 10 command output can change from a min of 1 V to a max of 10 V 11 Alarm Intervention Modes 11 a Absolute Alarm or Threshold Alarm A AL selection Alarm Spv 4 Hysteresis Absolute alarm with controller in heating i 2 Passo functioning par 11 Ack k selected HEAL and hysteresis value greater than 0 par 28 Simo R LAS gt 0 Alarm output n ui __ _R_LH4 lt 0 mint Alam Spy Absolute alarm with controller in heating gt functioning par 11 HcE E selected HEAL and i hysteresis value less than 0 par 28 A HU Time lt 0 On On Off Off SE 42 ATR243 User manual Time
72. erto c c Acceso a contatto chiuso Default 6 All accensione l uscita inibita se lo strumento in condizione di allarme Si attiva solo quando rientrato dalla condizione d allarme questa si ripresenta 76 CN243 Manuale d uso 28 A tHY Alarm 1 Hysteresis Isteresi allarme 1 999 999 digit gradi decimi per sensori di temperatura Default 0 0 29A idE Alarm 1 Delay 30 31 32 Ritardo allarme 1 180 180 secondi Default 0 Negativo ritardo in fase di uscita dall allarme Positivo ritardo in fase di entrata dell allarme A iSF Alarm 1 Setpoint Protection Protezione set allarme 1 Non consente all utente di variare il setpoint FrEE Modificabile dall utente Default Lack Protetto Hide Protetto e non visualizzato AL Cc Alarm2 Selezione allarme 2 L intervento dell allarme associato a AL2 Vedi paragrafo 11 d5 Disabilitato Default A AL Assoluto soglia riferito al processo b AL Allarme di banda H d AL Allarme di deviazione superiore L d AL Allarme di deviazione inferiore A c AL Assoluto soglia riferito al setpoint di comando St AL Allarme di stato attivo in Run Start cool Azione freddo cooling Vedi paragrafo 7 12 L b H Allarme di stato controllo carico Loop Break Alarm Es controlla lo stato dei contattori SSR o delle resistenze A250 Alarm 2 State Output Contatto uscita allarme 2 e tipo intervento n n 5 N O Start Normalmente aperto oper
73. etro 63 Gradients MA t i Allo scadere l uscita di comando disabilitata e lo strumento visualizza 5 oF La partenza del ciclo avviene al ogni Tempo accensione dello strumento oppure da ingresso digitale se abilitato per questo funzionamento vedi parametro 61 dL 1 Seconda selezione P 7 5 5 gl la partenza decisa solo dall attivazione 9 dell ingresso digitale a prescindere rr Mantenimento j r a dall impostazione del parametro 61 dL i Setpoint 1 Raffreddamento Alla partenza il regolatore raggiunge il Euri setpoint 1 seguendo il gradiente impostato nel parametro 62 GrAd Quando il processo lo raggiunge lo mantiene per il tempo impostato nel parametro 63 fA L Tempo Allo scadere l uscita di comando disabilitata e lo strumento visualizza StoP Gradiente Variante 5 5 c4 Selezionando 5 5 c4 Soft Start Cycle il regolatore si comporta come nella prima selezione P c4 con due importanti varianti Se all accensione il processo inferiore al SET1 lo strumento regola la potenza dell uscita al valore percentuale impostato sul parametro 62 Lr Hd Quando il processo supera il SET1 o trascorso il tempo impostato sul parametro 63 FR E il regolatore porta il processo al SET2 alla massima potenza e lo mantiene per un tempo infinito Se sul parametro 59 oP ilo impostato 5 5 4 possibile selezionare H d sul parametro 17 c S P in questo modo non viene pi
74. eviation Tune Operating Mode Automatic Manual Digital Input Gradient Maintenance Time User Menu Cycle Programmed Visualization Type Degree Retransmission Lower Limit Retransmission Upper Limit Retransmission Baud Rate Slave Address Serial Delay Lower Limit Output Percentage 37 37 37 37 37 38 38 38 38 38 38 39 39 39 39 40 40 40 40 40 41 41 41 41 41 41 42 42 42 42 ATR243 User manual 47 Introduzione Grazie per aver scelto un regolatore Omega Con il modello CN243 Omega rende disponibile in un singolo strumento tutte le opzioni relative alla connessione dei sensori e al comando di attuatori con in aggiunta un utile alimentazione a range esteso da 24 230 Vac Vdc Con le 18 sonde selezionabili e l uscita configurabile come Rel Comando SSR 4 20 mA e 0 10 Volt l utilizzatore o il rivenditore pu gestire al meglio le scorte di magazzino razionalizzando investimento e disponibilit dei dispositivi La serie si completa con i modelli dotati di comunicazione seriale RS485 Modbus Rtu e con la funzione di controllo del carico tramite trasformatore T A La ripetibilit in serie delle operazioni di parametrizzazione viene semplificata dai CN Config Module dotati di batteria interna che non richiedono cablaggio per alimentare il regolatore 1 Norme di sicurezza Prima di utilizzare il dispositivo leggere con attenzione le istruzioni e le misure di sicurezza contenute in questo manuale
75. g cooling with E O and t d 0 P b x P b fl COOL nu d b 0 1 P b HEAT __ ACTIVE COMMAND OUTPUT HEAT ace IN ALARMOUTPUT COOL ATR243 User manual 23 P b HEAT ACTIVE COMMAND OUTPUT HEAT ACTIVE i L ALARM OUTPUT COOL P b x P b l COOL LLL ACTIVE L COMMAND OUTPUT HEAT CIWS ALARM OUTPUT COOL Parameter co t c has the same meaning as the heating time cycle E c Parameter coa F cooling fluid pre selects the proportional band multiplier P 5 f 1 and the cooling P I D time cycle ca E c basing on the type of cooling fluid caa Cooling fluid type EE elope ie Hir Air 1 00 10 Dil Oil 1 25 4 He s Water 2 50 2 Once selected parameter coo F parameters Fb nud b and co t c can however be changed 8 Serial Communication CN243 R1R2F3 equipped with RS485 can receive and broadcast data via serial communication using MODBUS RTU protocol The device can only be configured as a Slave This function enables the control of multiple controllers connected to a supervisory system SCADA Each controller responds to a master query only if the query contains the same address as that in the parameter 5L Ad The permitted addresses range from 1 to 254 and there must not be controllers with the same address on the same line Address 255 can be used by the master to communicate with allthe connected equipment broadcast mode while with 0 all the devices
76. hen reaching setpoint also with P I D value different from 0 c rE Command Reset Type of reset for state of command contact always automatic in P I D functioning Aire Automatic reset Default Meg Manual reset lrE 5 Manual reset stored keeps relay status also after an eventual power failure c 5E Command State Error State of contact for command output in case of error c n Open contact Default c c Closed contact 32 ATR243 User manual 14 15 16 17 18 19 20 21 22 c td Command Led State of the OUT1 led corresponding to the relevant contact c n ON with open contact C C ON with closed contact Default c HY Command Hysteresis Hysteresis in ON OFF or dead band in P I D 999 999 digit degrees tenths for temperature sensors Default 0 0 c dE Command Delay Command delay only in ON OFF functioning In case of servo valve it also works in P I D and represents the delay between opening and closure of the two contacts 180 180 seconds tenths of second in case of servo valve Negative delay in switching off phase Positive delay in activation phase Default 0 c 5 4 Command Setpoint Protection Allows or not to modify the command setpoint value FrEE Modification allowed Default Lock Protected Ch Proportional Band Proportional band Process inertia in units example if temperature is in C 0 ON OFF E if equal to 0 Default 1 9999 digit d
77. hen the controller communicates via serial port ATR243 User manual 15 e Allows to increase the main setpoint e During the configuration phase allows to slide through 3 parameters Together with the key it modifies them e Pressed after the key it allows to increase the alarm setpoint Allows to decrease the main setpoint e During the configuration phase allows to slide through parameters Together with the key it modifies them e Pressed after the key it allows to decrease the alarm setpoint e Allows to display the alarm setpoint and runs the autotuning 10 SET function Allows to vary the configuration parameters 7 Controller Functions 71 Modifying Main Setpoint and Alarm Setpoint Values The setpoint value can be changed by keyboard as follows Press Display Do 1 or Value on display 2 changes La or decreases the main Visualize alarm setpoint on display 1 value being inserted Increases or decreases the alarm 3 or Value on display 2 changes ST 72 Auto Tuning Tuning procedure calculates the controller parameters and can be manual or automatic according to selection on parameter 57 tune 2 SET 73 Manual Tuning Manual procedure allows the user greater flexibility to decide when to update P I D algorithm work parameters The procedure can be activated in two ways e Running Tuning by keyboard Press key until display 1 shows the writing tunE with display 2 showing a FF press A di
78. hes maximum power up to setpoint 2 n NES When the process reaches maximum power this setpoint is maintained for the time set Setpoint 1 na ei on parameter 63 A E i On expiry the command output is disabled and controller displays Stof Cycle starts gt at each activation of the controller or via digital input if it is enabled for this type of functioning see parameter 61 dLE 1 Time Second selection Pr c4 start up is decided only on activation of the Hold digital input according to the setting of Setpoint 1 parameter 61 dLE On start up controller Natural cooling reaches setpoint 1 following gradient set in parameter 62 GrAd When the process reaches this gradient it is maintained for the time set on parameter gt 63 liH E On expiry command output is disabled and the controller displays 5E oF Setpoint Gradient M Time Variation 5 5 c4 Selecting 5 5 c4 Soft Start Cycle the controller will operate as per the first selection Pr cH but with two important variations If at starting the process is lower than SET1 the device regulates the output power according to the percentage selected on parameter 62 Lr Hd When the process is greater than SET1 or the time selected on parameter 63 MAE i is elapsed it reaches maximum power up to SET2 When the process reaches SET2 the controller keeps it to infinity If parameter 59 oP ilo is configured as 55 cH itis po
79. intervention threshold of the Loop Break Alarm in Amperes on parameter 48 L b H E e Set the intervention delay time of the Loop Break Alarm on parameter 49 b RH d e Itis possible to associate the alarm with a relay by setting the parameter AL AL cor HL Jas AL 4 If a remote control switch or SSR remains closed controller signals the fault by showing 1 6 A c on display 2 alternatively with a command setpoint If the power stage remains open or the load current is lower than the value set on b H E controller shows L b H n on display It is possible to display the current absorbed during the closure phase of the power stage Press Display Do Press until the writing This key enables to scroll Ri E H appears on display on display 2 the output 1 and display 2 shows the 1 SET percentage auto man current in amperes E H 0 selection setpoint and The value is also maintained alarms when no current circulates on the load Setting on parameter 48 L h H E the value 0 itis possible to visualize the current absorbed without generating the Loop Break Alarm ATR243 User manual 21 711 Digital Input Functions On CN243 model digital input can be enabled by using parameters 59 o P f15 and 61 dik i Parameter 59 oF fin NB When using this settings parameter 61 dLE is ignored gb 5 Switch two thresholds setpoint with open contact CN243 regulates on SET1 with closed contact regulates on SET2 2t 5
80. l Input Funzionamento ingresso digitale sel P59 deve essere cont o Fr c Vedi paragrafo 11 a5 Disabilitato Default 5E 5t Ciclo pre programmato con Start Stop rn n n Run N O abilita regolazione con contatto normalmente aperto rn n c Run N C abilita regolazione con contatto normalmente chiuso L c n n Lock conversion N O funzione mantenimento visualizzazione L c n c Lock conversion N C EunE Tune abilita l auto tuning manualmente ANA Automatic manual impulsive se abilitato su parametro 60 A NA c Automatic manual contact se abilitato su parametro 60 LrHd Gradient Gradiente di salita per Soft Start o ciclo pre programmato 0 Disabilitato 1 9999 Digit hour gradi ora con visualizzazione in decimi per sensori di temperatura Default 0 H E Maintenance Time Tempo mantenimento per ciclo pre programmato 00 00 24 00 hh mm Default 00 00 64 fl c P User Menu Cycle Programmed 65 Permette di modificare gradiente di salita e tempo di mantenimento dal men utente in funzionamento ciclo pre programmato a5 Disabilitato Default GrAd Solo gradiente MA E Solo tempo di mantenimento ALL Sia gradiente che tempo di mantenimento uit Visualization Type Definisce la visualizzazione per il display 1 e 2 IP 25 1 Processo 2 Setpoint Default LP EH 1 Processo 2 si spegne dopo 3 sec 5 gP 1 Setpoint 2 Processo 5 gH 1 Setpoint 2 si spegne dopo 3 sec LFA 1 Processo 2 Ampere d
81. le Impostando il parametro 54 possibile mediare il processo remoto R W 0 4001 Parametro 1 R W EEPROM 4002 Parametro 2 R W EEPROM 4072 Parametro 72 R W EEPROM Se vale 0 il controllo disabilitato Se diverso da 0 Il tempo massimo che pu trascorrere tra due inter rogazioni senza che il regolatore si porti in Off Line In Off Line il regolatore va in stato di Stop disabilita l uscita di comando ma mantiene gli allarmi attivi Con 1 su questa word si annullano gli effetti della scrittura su tutti gli indirizzi Modbus da 3001 a 3022 Il controllo ritorna al regolatore parametri modificati usando gli indirizzi seriali dal 4001 al 4072 vengono salvati in eeprom solamente dopo 10 dall ultima scrittura di uno dei parametri 70 CN243 Manuale d uso 9 Accesso alla configurazione Per parametri di configurazione vedi par 10 Premere SET per 3 secondi Effetto Eseguire Su display 1 compare 000 con la 1 cifra lampeggiante mentre sul display 2 compare PASS 2 Jol Si modifica la cifra lampeggiante si passa alla Inserire la password i234 successiva con il tasto ser SET per conferma Su display 1 compare il primo parametro e sul secondo il valore a XJo Y Scorre i parametri CK Je 3 Si incrementa o decrementa Inserire il nuovo dato che il valore visualizzato tenendo verr salvato al rilascio dei pr
82. ling frequency EHEH ICH Be H 5U H 38 H 33 cH I9 6H 16 1H Ic 5H IL H B 33H b c 5H 4 MH Dus 242 Hz Maximum speed conversion 123 Hz 62 Hz 50 Hz 39 Hz 33 2 Hz 19 6 Hz 16 7 Hz Default Ideal for filtering noises 50 60 Hz 12 5 Hz 10 Hz 8 33Hz 6 25 Hz 4 17 Hz Minimum speed conversion Visualization Filter Slow down the refresh of display to simplify reading dii Pear 5 S4 5 g SH SI LOO AM D LL ru Disabled with pitchfork max speed of display update Default First order filter with pitchfork Samples Mean Samples Mean Samples Mean Samples Mean Samples Mean Samples Mean Samples Mean Samples Mean 10 Samples Mean Maximum slow down of display update Disabled without pitchfork First order filter WO ON AM BW YN Tune Tuning type selection See paragraph 7 2 di Auto NA n 5Ync SHE Disabled Default Automatic P I D parameters are calculated at activation and at change of set point Manual launch by keyboard or digital IN Synchronized see word modbus 1025 only CN243 R1R2F3 Setpoint Deviation Tune Select the deviation from the command setpoint for the threshold used by autotuning to calculate the P I D parameters ATR243 User manual 39 59 60 61 62 63 0 5000 digit degrees tenths if temperature Default 10 oF io Operating Mode Select operating mode See paragraph 11 cont Co
83. mer Models with current transformer input for Loop Break Alarm function 3 Technical Data 3 1 General data 4x0 40 inch displays Indicators 4x0 30 inch displays Operating Temperature 0 45 C temperature Humidity 35 95 uR sealing IP65 front panel with gasket IP20 box and terminals Material PC ABS UL94VO self extinguishing Weight 165 g 20ABC 185 g 21 31ABC ATR243 User manual 5 3 2 Hardware data Extended range 24 230 Vac Vdc Powersupply 1506 50 60 Hz Consumption 5 5 VA 1 AN1 configurable via software Input Thermocouple type K S R J Automatic compensation of cold junction from 0 C to 50 C Thermoresistance Tolerance 25 C 0 2 1 digit for thermocouple input thermo resistance and V mA Cold junction accuracy 0 1 C C Analogue PT100 PT500 PT1000 Ni100 Impedance imput PTC1K NTC10K B 3435K OMEGA 0 10 V Ri gt 110 KQ NTC2252 OMEGA Linear 0 10 V 0 20 mA Ri lt 5 Q 0 20 or 4 20 mA 0 40 mV 4 20 mA Ri lt 5 O Current transformer 50 mA 1024 0 40 mV Ri gt 1 MO points on version CN243 R1R2F3 R1R2R3F4C4 Potentiometers 6 KO 150 KQ 2 Relays CN243 R1F2 R1R2F3 Contacts Relay 3 Relays CN243 R1R2R3F4C4 5 A 250 V output Configurable as command and or Resistive load alarm output 1 SSR Linear 0 4 20mA or 12V 30mA min 10 5 V DC 0 10 Volt Deselecting OUT2 relay on Configurable SSR V mA CN243 R1F2 Configurable
84. ms Configurable by parameters Insert JP4 and JP6 as in figure to select the amperometric transformer input 5 1 Digital Input on CN243 R1F2 12V GND Digital input using parameter dit i ID The use of digital input in this version is possible only with TC sensors 0 10 V 0 4 20 mA and 0 40 mV Select internal jumper JP3 as in figure 5 1 m Digital Input on CN243 R1R2F3 and CN243 R1R2R3F4C4 12V GND ID 15 Digital input using parameter dt i Insert JP4 as in figure to select the digital input 14 ATR243 User manual 6 Display and Key Functions 6 1 Numeric Indicators Display Zum Normally displays the process During the configuration phase it Ic 34 displays the parameter being inserted 5 294 Normally displays the setpoint During the configuration phase it 1d displays the parameter value being inserted 6 2 Meaning of Status Lights Led ON when the output command is on 3 C1 C2 C1 with relay SSR mA Volt command or C1 open and C2 close for a motorised valve command 4 Al A2 A3 ON when the corresponding alarm is on 5 MAN ON when the Manual function is on 6 TUN ON when the controller is running an Autotune cycle 7 REM ON w
85. nges not model changes whenever an improvement is possible This affords our customers the latest in technology and engineering OMEGA is a registered trademark of OMEGA ENGINEERING INC Copyright 2015 OMEGA ENGINEERING INC All rights reserved This document may not be copied photocopied reproduced translated or reduced to any electronic medium or machine readable form in whole or in part without the prior written consent of OMEGA ENGINEERING INC Where Do I Find Everything I Need for Process Measurement and Control OMEGA Of Course Shop online at omega com TEMPERATURE IA Thermocouple RTD amp Thermistor Probes Connectors Panels amp Assy I Wire Thermocouple RTD amp Thermistor Calibrators amp Ice Point References I Recorders Controllers amp Process Monitors A Infrared Pyrometers PRESSURE STRAIN AND FORCE IA Transducers amp Strain Gages IA Load Cells amp Pressure Gages IA Displacement Transducers IA Instrumentation amp Accessories FLOW LEVEL IA Rotameters Gas Mass Flowmeters amp Flow Computers A Air Velocity Indicators IA Turbine Paddlewheel Systems lA Totalizers amp Batch Controllers pH CONDUCTIVITY LA pH Electrodes Testers amp Accessories lA Benchtop Laboratory Meters lb Controllers Calibrators Simulators amp Pumps A Industrial pH amp Conductivity Equipment DATA ACQUISITION I Data Acquisition amp Engineering Software I Communications Based A
86. nte all operatore di variare il valore impostato FrEE Modificabile dall utente Default Lack Protetto Hide Protetto e non visualizzato AL J Alarm 3 Selezione allarme 3 L intervento dell allarme associato a AL3 Vedi paragrafo 11 di 5 Disabilitato Default A AL Assoluto soglia riferito al processo b AL Allarme di banda H d AL Allarme di deviazione superiore L d AL Allarme di deviazione inferiore A c AL Assoluto soglia riferito al setpoint di comando SEAL Allarme di stato attivo in Run Start conL Azione freddo cooling vedi par 7 12 L b H Allarme di stato controllo carico Loop Break Alarm Es controlla lo stato dei contattori SSR o delle resistenze 9 Dipende dall impostazione del parametro 5 E n e del parametro d P 78 CN243 Manuale d uso 40 41 42 43 44 45 46 H35 n Alarm 3 State Output Contatto uscita allarme 3 e tipo intervento n n 5 N O Start Normalmente aperto operativo dallo start Default n c 5 N C Start Normalmente chiuso operativo dallo start n n t N O Threshold Normalmente aperto operativo al raggiungimento dell allarme n r t N C Threshold Normalmente chiuso operativo al raggiungimento dell allarme H3rE Alarm 3 Reset Tipo di riarmo del contatto dell allarme 3 HrE Reset automatico Default rE Reset manuale riarmo reset manuale da tastiera rE Reset manuale memorizzato mantiene lo stato del rel anche dopo un
87. ntroller Default Pr cH Pre programmed cycle See paragraph 7 7 ES Setpoint change by digital input 2 5 1 Setpoint change by digital input with impulse command jE 5 3setschange by digital input with impulse command 4E 5 1 4sets change by digital input with impulse command t rE5 Reset time custom function P c 5 5 Pre programmed cycle with Start Stop only by digital input Au A Automatic Manual Enable automatic manual selection See paragraph 7 6 a5 Disabled Default En Enabled EnSt Enabled with memory dGt 1 Digital Input Digital input functioning P59 selection must be cont or Fr cH See paragraph 11 gi Disabled Default St St Start Stop rn n n Run N O enables regulation with N O contact rn n c Run N C enables regulation with N C contact L c n a Lock conversion N O stop conversion and display value with N O L c n c Lockconversion N C stop conversion and display value with N C tunE Manual Tune by digital input ALMA Automatic Manual Impulse if enabled on parameter 60 A NA c Automatic Manual Contact if enabled on parameter 60 UrAd Gradient Rising gradient for Soft Start or pre programmed cycle 0 Disabled Default 1 9999 Digit hour degrees hour with display of tenth for temperature sensor H E Maintenance Time Maintenance time for pre programmed cycle 00 00 24 00 hh mm Default 00 00 12 13 Display of decimal point depends on setting of
88. o 63 71 Modifica valore setpoint principale e setpoint di allarme sess 63 Id AUG 63 7 3 Lancio del Tuning Manuale loca 63 7 4 Lancio del Tuning AutomMaticoO ssesssssesssssseeesssseseresssseeesssseseresssseeeooossseeresssseeoosssssreessseeeessss 64 4 SOSTON ases E E E aa eds Gea 64 7 6 Regolazione automatico manuale per controllo 96 uscita sess 64 7 7 XCIclobDre DFOQOFO DEDI Ouseec eiecit mol deme meri brine predi On ae Ere rdi em g s 65 48 CN Config Module opzionale 66 CURZI 67 7 10 Loop Break Alarm da ingresso T A Trasformatore Amp sse 68 FAV F nzionraqytigressodigitulB usuncsdeddeump a etes Nine en So atenta teet EDD 68 712 Funzionamento in doppia azione caldo freddo esses 69 8 Comunicazione SCI eo 71 9 Accesso alla COMMGUTAZIONS caio 75 9 1 Caricamento valor di default ssi een diim dina E anata 75 10 Tabella parametri di configurazione uil 76 11 Modi d intervento dci 89 12 Tabella segnalazioni GANOMalle ui 92 13 Configurazione uel aU ie M 92 4 ATR243 Manuale d uso Introduction Thank you for choosing a Omega controller With CN243 model Omega integrates in a single device all options for sensor reading and actuators command beside extended supply range 24 230 Vac Vdc With 18 selectable sensors and outputs configurable as relay SSR command 4 20 mA and 0 10 Volt the user or ret
89. ona il moltiplicatore di banda proporzionale P b ed il tempo di ciclo co t c del P I D freddo in base al tipo di fluido refrigerante Tipo di fluido co i eine EUER refrigerante Har Aria 1 00 10 Dil Olio 1 25 4 Heo Acqua 2 50 2 Una volta selezionato il parametro coo F i parametri Fb gud b e co t c possono essere comunque modificati 66 CN243 Manuale d uso 8 Comunicazione Seriale Il CN243 R1R2F3 con RS485 pu ricevere e trasmettere dati via seriale tramite protocollo MODBUS RTU Il dispositivo pu essere configurato solo come Slave Questa funzione permette il controllo di pi regolatori collegati ad un sistema di supervisione Ciascuno strumento risponder ad un interrogazione del Master solo se questa contiene l indirizzo uguale a quello contenuto nel parametro SL Fd Gli indirizzi permessi vanno da 1 a 254 e non devono esserci regolatori con lo stesso indirizzo sulla stessa linea L indirizzo 255 pu essere usato dal Master per comunicare con tutte le apparecchiature collegate Modalit broadcast mentre con 0 tutti i dispositivi ricevono il comando ma non prevista alcuna risposta Il CN243 pu introdurre un ritardo in millisecondi della risposta alla richiesta del Master Tale ritardo deve essere impostato sul parametro 72 5E dE Ad ogni variazione dei parametri lo strumento salva il valore in memoria EEPROM 100000 cicli di scrittura mentre il salvataggio dei setpoint avviene con un ritardo di 10
90. parameter 5E n and parameter d P Display of decimal point depends on setting of parameter 5E n and parameter d P 40 ATR243 User manual 64 u c P User Menu Cycle Programmed Allows to modify rising gradient and maintenance time from user menu when pre programmed cycle is operating a5 Disabled Default LrHd Gradient HRH t Maintenance time LL Both gradient and maintenance time 65 unt Visualization Type Select visualization for display 1 and 2 IP 25 1Process 2 Setpoint Default IP 2H 1 Process 2 Hide after 3 sec IS 2P 1 Setpoint 2 Process 5 2H 1 Setpoint 2 Hide after 3 sec LP E H 1 Process 2 Ampere T A input 66 deELr Degree Select degree type OF Centigrade Default SR Fahrenheit 67 rEtr Retransmission Retransmission for output 0 10 V or 4 20 mA select Jumpers JP5 JP7 and JP9 Parameters 68 and 69 define the lower and upper limits of the scale d iS Disabled uo P Retransmits process in Volt MA F Retransmits process in mA un c Retransmits command setpoint in Volt HH c Retransmits command setpoint in mA un n F Volt output percentage HH a P mA output percentage un H Volt alarm 1 setpoint MA A mAalarm 1 setpoint uwo A c Volt alarm 2 setpoint A A mA alarm 2 setpoint uo L A Volt T A NA L A mAT A 68 LoL Lower Limit Retransmission Output V mA retransmission lower limit range 999 9999 digit degrees tenths for temperature sensors Default 0 69 uFL r Upp
91. r and upper limits if on input there are values out of 0 4 20mA or 0 10V To enable the LATCH ON function select chosen configuration for parameter L RE c For the calibration procedure refer to the following table Press Display Do Exit parameters configura Place the sensor on minimum 1 t tion Display 2 shows the operating value associated simultaneously writing REc with Lol 1 TM Place the sensor on maximum Set the value on minimum i 2 f Display shows Lab operating value associated with u FL 1 To exit standard procedure 3 Set the value to maximum press SET For virtual zero The display shows H GH settings place the sensor on the zero point Set the virtual zero value Display shows u irt 4 SET NB For selection of u Din To exit procedure press str the procedure in point 4 should be followed on each re activation Max Min Zero E i E nia A KO M 2 Thetunin g procedure starts by exiting the configuration after changing the parameter 20 ATR243 User manual 7 10 Loop Break Alarm On Current Trasformer This function allows to measure load current and to manage an alarm during malfunctio ning with power in short circuit or always off The current transformer connected to terminals 15 and 16 must be 50 mA sampling time 80 ms Set end scale value of the current transformer in Amperes on parameter 47 L A Set the
92. rranted include but are not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA either verbal or written OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER EXPRESSED OR IMPLIED EXCEPT THAT OF TITLE AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED LIMITATION OF LIABILITY The remedies of purchaser set forth herein are exclusive and the total liability of OMEGA with respect to this order whether based on contract warranty negligence indemnification strict liability or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by OMEGA is not intended to be used nor shall it be used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear installation or activity medical application
93. splay 2 shows an TUN led switches on and the procedure begins e Running Tuning by digital input Select EunE on parameter 61 dLE 1 At first activation of digital input commutation on front panel TUN led switches on and at second activation switches off 16 ATR243 User manual 74 Automatic Tuning Automatic tuning activates when the controller is switched on or when the setpoint is modified to a value over 35 To avoid an overshoot the treshold where the controller calculates new P I D parameters is determined by the setpoint value minus the Set Deviation Tune see parameter 58 5 d Eu To exit Tuning and keep P I D values unchanged press key until display 1 shows the writing EunE and display 2 shows an Press X display 2 shows aFF TUN led switches off and procedure finishes 75 Soft Start To reach the setpoint the controller can follow a gradient expressed in units example Degree Hours Enter the gradient on parameter 62 GrAd with chosen Units Hours only on subsequent activation the controller uses Soft Start function If parameter 59 oF flo is set on cont and parameter 63 TH i is different from 0 after switch on and elapsing of the time set on parameter 63 setpoint does not follow the gradient anymore but it reaches final setpoint with maximum power Autotuning does not work when only the par GrAd is different from 0 If parameter 63 NA E i is different from 0 and parameter 57 tune is set on Auto th
94. ssible to select H dE on parameter 17 c SF SET1 is no longer displayed and SET2 label becomes SET Starting the manual tune during the regulation on SET1 TUN led switches ON only when the regulation switches to SET2 The autotuning manual or automatic works only if SET2 is being regulated If the autotuning is launched during regulation on SET1 it doesn t start until the regulation switches to SET2 18 ATR243 User manual 7 8 CN Config Module optional Parameters and setpoint values can be duplicated from one controller to another using the CN Config Module 2 modes are available e With the controller connected to the power supply Insert CN Config Module when the controller is off On activation display 1 shows Elo and display 2 shows only if the correct values are saved in the CN Config Module By pressing key display 2 shows Lafo then confirm using ser key Controller loads the new value and restarts e With the controller not connected to power supply The CN Config Module is equipped with an internal battery with an autonomy of about 1000 uses 2032 button battery replaceable Insert the CN Config Module and press the programming buttons When writing the parameters led turns red and on completing the procedure it changes to green It is possible to repeat the procedure without any particular attention LED ROSSO acceso in programmazione Red Light waiting for progr
95. troller exits from programming 9 1 Loading default values This procedure allows to restore factory settings of the instrument Press for 3 seconds Display Display 1 visualizes 0 000 with 1st digit blinking while display 2 shows FASS Do 2 DoW Change blinking digit and move to the next one with ser Enter password 9999 to confirm Device loads default settings Turn off and restart the instrument ATR243 User manual 29 10 Table of Configuration Parameters The following table includes all parameters Some of them will not be visible on the models which are not provided with relevant Hardware data 1 Laub Command Output Command output type selection see tables c Di Default necessary for using process and setpoint retransmission function with Volt mA output c o2 Command on relay output Q2 c55r Commandin tension for SSR c uAl Servo valve command with open loop cHe0 4 20 mA command cg 0 20 mA command c 0 19 0 10 V command CN243 R1F2 COMMAND ALARM 1 c nl Q1 Q2 c BE Q2 Q1 ESSE SSR Q1 c uHL Q1 opens Q2 closes cH 00 4 20 MA Q1 ciei 0 20 MA Q1 c D ID 0 10V Q1 CN243 R1R2F3 COMMAND ALARM 1 ALARM 2 c nl Q1 Q2 SSR E GE Q2 Q1 SSR Bor SSR Q1 Q2 c uAL Q1 opens Q2 closes SSR cH e 4 20mA Q1 Q2 Uol 0 20 MA Q1 Q2 c Li IL 0 10V Q1 Q2 CN243 R1R2R3F4C4 COMMAND
96. ziona anche in P I D e rappresenta il ritardo tra l apertura e la chiusura dei due contatti 180 180 secondi decimi di secondo in caso di servo valvola Negativo ritardo in fase di spegnimento Positivo ritardo in fase di accensione Default 0 c 5 Command Setpoint Protection Consente o meno di variare il valore del setpoint di comando FrEE Modificabile dall utente Default LOCF Protetto Pb Proportional Band Banda proporzionale Inerzia del processo in unit es se temperatura in C OON OFFset uguale a 0 Default 1 9999 digit gradi per sensori di temperatura En Integral Time Tempo integrale Inerzia del processo in secondi 0 0 999 9 secondi 0 integrale disabilitato Default 0 0 E d Derivative Time Tempo derivativo Normalmente del tempo integrale 0 0 999 9 secondi 0 derivativo disabilitato Default 0 0 EE Cycle Time Tempo di ciclo per P I D su teleruttore 10 15 sec per P I D su SSR 1 sec o tempo servo motore valore dichiarato da produttore 1 300 secondi Default 10 ool Output Power Limit Seleziona il valore massimo per la percentuale dell uscita di comando 0 100 Default 100 Es con c nut selezionato 0 10 V e impostazione su o Fol al 90 l uscita di comando pu variare da un minimo di 0 V al massimo di 9 V 5 Dipende dall impostazione del parametro 5 E n e del parametro d P Manuale d uso CN243 75 23 24 25 26 27 AL Alarm 1 S
97. zione H d Pi Allarme di deviazione superiore e valore di setpoint allarme maggiore di 0 e valore di isteresi maggiore di 0 par 28 A LHH gt 0 Comand Spv Somana gt p Alarm Spv Hysteresis arameter 4 LAY gt 0 f 7 2 gt Time On On Alarm output Off Off Allarme di deviazione superiore valore di setpoint allarme minore di 0 e valore di isteresi maggiore di 0 par 28 A HY gt 0 11 e Pv x Comand Spv Hysteresis arameter 1H9 gt 0 Alarm Spv Time Alarm output On EE o NN o Allarme deviazione inferiore selezione L d AL Allarme di deviazione inferiore valore di setpoint allarme maggiore di 0 e valore di isteresi maggiore di 0 par 28 A LHH gt 0 Hysteresis f arameter EON 01H 20 Alarm Spv Comand Spv Time Alarm output On On NENNEN eee Allarme di deviazione inferiore valore di setpoint allarme minore di 0 e valore di isteresi maggiore di 0 par 28 A LHH gt 0 q L esempio riferito all allarme 1 la funzione abilitabile anche per gli allarmi 2 e 3 sui modelli che li prevedono b Con isteresi minore di 0 A LH4 lt 0 la linea tratteggiata si sposta sopra il setpoint di allarme Manuale d uso CN243 87 12 Tabella segnalazioni anomalie In caso di mal funzionamento dell impianto il controllore spegn