1. Signal ON Signal OFF Signal ON Signal OFF i t1 Delay Time Dee ame t2 Injection Time Gate Open Time A MODE B MODE 6 Assembly Sequence 1 Assembling the Solenoid Valve Block C users MANUAL 1 Assemble the solenoid valves seal and air manifold using the M4 35 screws Install the Blanking Plugs in the air manifold 3 Assemble the Air Supply connector and silencer in air manifold 4 Assemble the Solenoid Vaive Blod Assembly to the mould using the M5 70 flat head cap screws Ensuring that the sealing gasket is correctly fitted Connect the Solenoid Valve magnet power cable to a 10P or 16P Connection sequence HAN 10A 250V 16A HAN 16A 250V 16A MALE P N 09 20 010 2612 MALEP N 09 20016 2612 Oleseccecs leeese 5 Assemble the connected rectangular connector to mold using M4 12 bolt 7 Mould Machining Machine the mould by referring to the drawing issued for the YUDO Sequence Timer System It is recommended that the equipment is installed on the upper surface of mould opposite the operator position Machine the clamping plate spacer block and hold plate at the selected solenoid valve position on the mould to the details illustrated below HOLD PLATE r 16P 48 Use of 48 rectangular connector 10P Each of land LI dimension is dimension of position to be Processed according to each Zone lt 99 O S a Q i Z5 z vesec 19 24 2 25 5 25 5
2. 4 MS TAP DP15 C user s MANUAL 8 Valve Sequence Timer and Equipment
3. 1 Uses YUDO have produced the Sequence Injection Timer SIT500 Series to provide a means of controlling the mould filling sequence when using Valve Gate Hot Runner Systems The Sequence Injection Timer enables the Valve Gates of a Hot Runner System to be individually controlled to provide the following benefits 1 Removal or Positioning of Weld Lines Quality of the moulded part can be improved by removing or repositioning of weld lines on visual surfaces or sections where a weld line would cause a weakness 2 Regulation of the Injection Quantity by Gate Operation Flash occurrence or short moulding is improved by the regulation of the Injection Quantity from each individual gate 3 Reduction of Clamping Force Injection is performed with minimum damping force because all of the gates are not opened simultaneously 4 Reduction of Flow Marks Flow marks are minimized by being able to raise the injection rate at the gate 2 Power Supply gt Mains Power Supply Timer case Single phase AC 220V 50 60 Hz gt Injection Signal Input Power Supply DC 24V AC 110V AC 220V Free Voltage gt Solenoid Valve Voltage DC 24V AC 110V AC 220V gt Operating Temperature Range 10 C 50 C gt PCB Structure 1 Power PCB Timer power 2 MAIN PCB MPU out signal input out injection 3 DISPLAY Switch signal input condition display C use 3 Control SIT 500 SEQUEN Panel Layout Sequence Injection Timer SIT 500 1 SIGN
4. AL LED If injection signal is entered lamp is tumed on 2 OPEN LED If gate is opened lamp is tumed on CE When it is manually operated in lamp is also tumed on INJECTION TIMER 3 DEL The time until gate is started to be opened after receiving injection signal Mode A and mode B operate in the same O SIGNAL OPEN O way Basic setting value 3 seconds DELI SEC 4 OPEN The time when gate is being opened Counting continues in mode A until injection signal ends Gate opens only during setting time in mode B R S MANUAL Basic setting value 3 seconds 5 DEL SET Key Akey to set gate opening time after injection signal This is used by being pressed simultaneously with key 6 orkey SAVE is displayed 5 seconds after setting and then setting value is saved If signal is tumed on before SAVE display it operates with the changed value and if AC input power is tumed off and then tumed on setting value is not saved 6 UP KEY A key to set up time by pressing DEL or OPEN SET Key simultaneously 7 OPEN SET Key A key to set the time when gate is being opened This is used by pressing key 6 or key 6 simultaneously Save function is the same as DEL SET key 8 DOWN KEY Akey to tum down time setting by pressing DEL or OPEN SET key simultaneously 9 MANU Key Akey to be operated when opening gate manually Gate is opened only when key is being pressed 10 MODE A LED Lamp is tumed on when it is
5. ge with the Solenoid Valve voltage specifications Basic Setting AC 220V DC 24V YXA 110V ao AC 110V SAI 220V oo AC 220V 431l 5 Mode Specification YUDO Sequence Injection Timer SIT 500 may be set in two modes The opening dosing operation of the gate differs according to the setting mode as illustrated below 1 MODE A Selecting mode A After the injection gt Gate Open signal has been received the gate Signal ON Signal OFF remains Closed during the DEL time t1 t1 Delay Time After the DEL time has elapsed the gate Opens and remains open until the end of the injection signal Ex Injection time 10 seconds DEL Time t1 3 second setting Operation Gate opens 3 seconds after receiving the injection signal and remains open for 7 seconds and then closes 2 MODE B Gate Open g B the inj T signal has been received the gate Signal ON Signal OFF remains Closed during the DEL time t1 t1 Delay Time t2 Injection Time Gate Open Time After the DEL time has elapsed the gate Opens for the OPEN time setting t2 Ex Injection time 10 seconds DEL Time 3 second setting OPEN time 4 second setting Operation Gate opens 3 seconds after receiving the injection signal and remains in the open condition for 4 seconds and then doses 3 Gate Opening by Mode Type Selection It is possible to set various conditions by selecting the DEL and OPEN timer Settings as below T3 t i a E TE e
6. ough the use of the DEL SET amp gt gt UP DEL SET amp lt lt DOWN switches 2 All MODE A B can be set 3 Setting range 4 If there is no adjustment key in for 5 seconds Save is displayed and Setting is completed Display time functions first when the injection signal is entered during the set time The system functions even during adjustment f MANU is pressed during the period of setting system operates manually Will not function during the period of adjustment If the adjustment key remains pressed data can be entered continuously 8 When data are saved from 1 Sec setting to the 999 Sec 0 1 Sec setting is displayed as 99 9 Sec and 0 01 Sec setting as 9 99 Sec Even the saved time is changed according to the multiple of the time setting 1SecSetting 0 1 SecSetting 0 01 Sec Setting SettingRange 0 999Sec 0 99 9Sec_ 0 9 99Sec__ 2 Adjusting OPEN time 1 Setting OPEN time through the use of the OPEN SET amp gt gt UP OPEN SET amp lt lt DOWN switches C users MANUAL Only MODE B can be set 3 DELAY tame adjustment item 3 6 same 3 Setting output voltage Remove the rear side of the Timer Case Remove M4 bolt Select the desired voltage from C 24V AC 110V and AC220V and insert the 2 jumpers into the top and bottom for the selected voltage on of the PCB attached to the rear side of the separate case Refer to the following figure Match the selected volta
7. set as A type Refer to mode setting method 11 MODE BLED Lamp is tumed on when it is being set as B type Refer to mode setting method 12 Lamp is tumed on when gate is opened manually 13 Module Handle 14 Power switch On Off 15 Module Securing Screw 4 Function 1 Operation after power is connected 1 2 When the power is initially connected the system conducts self diagnosis and the segment number starts count from 1 to 9 at an interval of 0 3 seconds LED blinks from LE1 to LE5 in sequence 3 After the 1 self diagnosis the memory status is indicated 2 Mode and time unit setting 1 Press MANU amp OPEN SET switches simultaneously and connect power to convert to mode setting 1 Set starts blinking in the delay time display segment SET 2 Time set time unit saved in the open time display segment starts blinking 1 0 1 0 01 aligned to the right side 2 Press MANU and the MODE display LED indicates the selected mode by blinking MODE A B 3 Press gt gt UP and the open time display segment moves UP 0 01 gt 0 1 0 1 gt 1 4 Press lt lt DOWN and the OPEN TIME display SEGMENT moves DOWN 1 gt 0 1 0 1 gt 0 01 5 Setting is completed if there is no more input for 5 seconds 6 All input output function is suspended during the time of setting 7 TIME setting not executed 3 Time setting No blinking 1 DELAY time adjustment 1 Setting Delay time thr
Download Pdf Manuals
Related Search
Related Contents
Controllo delle funzioni del sistema - Psn Consulter le document en PDF - Bureau de la sécurité des StarTech.com 20m Coax High Resolution Monitor VGA Cable - HD15 M/M USB Function Sample Code User`s Manual Manuale utente dp User Guide - v2.x - Section 5 Day to Day System Usage Nadir.10 AENA EN CIFRAS HP 85062A 3.5 mm Electronic Calibration Kit HV-300取付・取扱説明書 Copyright © All rights reserved.