1. 7 Command 5_ KG 7 4 H M M Switches the output operating in stable mode to the opposite state after H hours and MM minutes The H parameter can be from 0 to 9 and the MM parameter from 00 to 59 If a new command 5 is entered during an already initiated command 5 the new settings of H and MM will take place of the previous ones If command _1 is entered during an already initiated command 5 it will override command 5 and the lock will immediately switch the stable output If the lock is currently processing command 5 and the countdown is grater then 15 minutes the device generates a short acoustic signal every minute If this time is shorter then 15 minutes the lock will generate a short acoustic signal every 2 seconds This is used to indicate that the switching of stable output will take place Command 6 __ KD Switches ON the output operating in pulse mode for a time of C4C5 seconds being the calibrated delay Command 7 __ KZ Switches the output operating in stable mode from ON to OFF This only takes place if the main code command 4 permits this Command 4 must be entered every time before command 7 is to be use Command 8 _ KG KSI If the use of the KS code is enabled parameter C2 1 then stable output can only be switched from OFF to ON after this command is initiated The KS code must be entered within 30 seconds from the entry of the main code KG Command 9 _ Usually this
2. and the switched current cannot exceed 150 mA TRANSISTOR OUTPUT PREALARM When this output is activated the potential connected to its circuit is shorted to negative ground of the power supply When the output is turned off it stays in a state of high impedance This output is used to signal PRALARM DURESS or retransmit the pressing of in BELL function Potentials connected to this output cannot exceed values of the power supply s positive potential and the switched current cannot exceed 150 mA CONTROLLING THE OUTPUTS Both the relay and the AUX outputs are controlled by codes entered from the lock s keypad and can operate in pulse as well as stable mode The PREALARM output can be controlled by the PREALARM DURESS or BELL function Operating modes are selected by jumper settings on the back of the lock s PCB Pulse output mode Outputs operating in pulse mode are normally in the OFF state Commands 3 or 6 activate the output for a period of time defined by the calibrated delay C4C5 parameters When this time period surpasses the output returns to the OFF state If the activating commands are entered during the calibrated delay the total active time is extended by C4C5 counting from the time of a previous command The delay on the stable output can be set from 1 to 99 seconds Stable output mode Every time a appropriate code is initiated the stable output is flipped to a state opposite of the state that the outp
3. key is used to end code entry Additionally if C3 1 was set during configuration and is held down the PREALARM output is activated After the key is released the output remains active for 2 seconds after which it switches off This key can be used for calling security or signalling the intention to enter the premises CONFIGURATION EEPROM RESET In order to configure the electronic keypad lock the EEPROM reset procedure should be carried out first Then a sequence of five digits C1 C5 should be entered according to the steps below Turn off the power supply Switch the jumper from the NORMAL position to EEPROM RESET Turn on the power supply Wait few second the device will generate sound periodically Switch the jumper from the EEPROM RESET position to NORMAL Wait until two sounds Enter five digits C1 C5 to configure the lock Wait for the device to sound three beeps which will acknowledge the new configuration The unit is ready for operation Configuration parameters definition C1 Enables multiple code reprogramming C1 0 codes can only be set once C1 1 codes can be set any number of times IMPORTANT If multiple code programming is disabled C1 0 the device will only permit a single entry of the selected code Once programmed it will not be possible to change the code without a need for EEPROM RESET C2 Enables the use of KS code C2 0 disable
4. CK The device should be fastened to a vertical plane of a construction All electric connections should be done before connecting the lock to a power supply If the electromagnetic door lock is connected to the same power source as the keypad unit it is important to feed the negative potential using a separate wire SL1000A SL1000B and SL1000C units should be protected from atmospheric influences such as rain or snow as well as away from heat and humidity sources The SL1000H lock is protected from atmospheric influences such as rain or snow That s why it can be mounted outdoors without additional shielding or protection RELAY SWITCH OUTPUT The relay output can operate in pulse or stable mode When the relay is activated the OPEN led is lit whereas the CLOSED led lights if the relay is not active An overtension component oxide varistor is connected in parallel with the relay s contacts This element protects the relay s contacts from damage due to overtension when switching inductive loads such as the electromagnetic lock therefore extending the relay s life TRANSISTOR OUTPUT AUX When this output is activated the potential connected to its circuit is shorted to negative ground of the power supply When the output is turned off it stays in a state of high impedance The AUX output can operate in both pulse and stable modes Potentials connected to the AUX cannot exceed values of the power supply s positive potential
5. SL 1000 e ELECTRONIC KEYPAD LOCK roger ROGER s c SL1000 v1 1 03 12 1999 DESIGN AND USE The SL1000 electronic keypad lock is designed for operation in anti burglary alarm systems The device can simultaneously function as a standalone access control unit based on an electromagnetic lock The SL1000 is equipped with tree outputs Two of which are transistor outputs and the third is a relay output with a pair of NO NC connectors The electronic keypad lock has four codes that enable programming and control of its outputs All codes and parameters configuring the lock s operation are stored in non violate EEPROM memory insensitive to power failures Different configuration variations enable effective adaptation to specific applications by choosing the desired operating manner The lock s synthetic silicone based keypad guarantees long life operation Operation in the dark is easy because the lock s keypad is lit up The SL1000 is available in several designs differing in mechanical construction The following versions are currently available SL1000A Metal casing lit available up keypad freely SL1000B ABS plastic casing lit up keypad freely available SL1000C Metal casing with special protection lid Lit up keypad keypad SL1000H Metal casing moisture proof special keypad protection lid The keypad is designed for outdoors operation INSTALLING THE ELECTRONIC KEYPAD LO
6. arm generation due to entering the main code under duress command 2 BELL FUNCTION This function activates the PREALARM output after the key is pressed down longer then 0 5 seconds The output remains in the active state for as long as the key is held pressed down After the key is released the output remains active for two seconds after which it switches off This function is usually used for calling security or signalling the intention to enter the premises LOCK S CODES KG Main code This code can consist of 2 to 6 digits It is used to control all of the lock s outputs as well as for programming KS Vault code This is a four digit code which can be enabled or disabled during the lock configuration procedure If this code is enabled the stable mode output will only switch from OFF to ON after the main code KG is entered followed by the vault code KS KD Door code This is a four digit code which is only used for controlling the output operating in the pulse mode It is used for switching on the pulse output for a time defined by C4C5 KZ Locking code This is a four digit code which is only used for controlling the output operating in the stable mode It causes the stable mode output to switch from ON to OFF Use of this code requires command 4 to be entered before PROGRAMMING OF CODES Programming of codes can be done only once or can be done any number of times after the EEPROM RESET
7. ax 150mA 20 50 degrees C Max 1 5A 24Vdc ac 1139 ON PZ5 NORMAL POSITION PZ6 RELAY MONOSTABLE PZ7 AUX MONOSTABLE SL1000B Wav 1V aad Output control modes N J umper UI Ls 15 6 output AUX Relay output Function STABLE STABLE STABLE PULSE PULSE STABLE PULSE PULSE Unit RESET Normal operation Relay contact selection Contacts normally open NO Contacts normally closed NC EEEE NETES Pasion J6 J5 J4 J3 J2 J1 SL1000A J1 J2 J3 J4 J5 J6 12V SL1000C SL1000H max 150 mA O a Max 150 mA 12V vi NC 1kU Var 24V 4 1 2 3 4 8 9 COM NO PRE AUX LED NC AL 12VDC SL1000A SL1000C SL1000H TAMPER
8. procedure It depends on setting of C1 parameter The following scheme illustrates how code programming is performed PREVIOUS KG NEW KG NEW KG NEW KD NEW KZ IMPORTANT Pressing in places specified by enables the user to exit the programming function earlier while saving all previously programmed settings If the use of the KS code is enabled parameter C2 1 it can be programmed according to the following scheme PREVIOUS KS NEW KS NEW KS LOCK S COMMANDS The electronic keypad lock uses acoustic signals to indicate three phases of command entry a single short signal indicates that a key has been pressed two series of two signals indicate that part of a command was entered correctly and that the device awaits further entry three acoustic signals indicate that the entire command was entered successfully a single long signal lasting for about 2s indicates an error Command 1 __ KG Switches the output operating in stable mode to an opposite state of that before the command was initiated Command 2 _ KG N Acts in the same manner as command 1 and switch on signalling the PREALARM DURESS function Command 3 __ KG Switches on the output operating in pulse mode for a time defined by the calibrated delay It works identical to command 6 Command 4 _ KG J Allows for a single use of command
9. s the use of the KS code C2 1 enables the use of the KS code C3 Defines the function of the PREALARM transistor output C3 0 the output signalling the PREALARM DURESS function C3 1 the output signalling the BELL function C4C5 Defines the calibrated delay on the stable output 00 99 seconds After the C5 digit is entered the lock is configured and changes are stored in memory After configuration the device automatically sets the lock s codes to the following values KG 1234 kS 9999 KD 1111 KZ 2222 If en error is made during the entry of C1 C5 digits the device signals it by sounding the error beep All previous settings are cancelled and the lock restart configuration procedure The user must re enter digits C1 C5 Example The installer has RESET the EEPROM and entered the following digit sequence 1 O 1 2 5 This has the following meaning codes can be set any number of times C1 1 the use of the vault code KS is disabled C2 0 the PREALARM output performs the BELL function when the key is held pressed down C3 1 the calibrated delay on the stable output is set to 25 seconds C4C5 25 TECHNICAL DATA Power supply voltage 11 15 Vdc Current consumption Typical 15mA Current consumption with activated relay output Max 60mA Operating environment temperature range Relay output load PREALARM and AUX output load M
10. ut was previously in The output can be switched immediately after command 1 is entered or with a delay if command 5 was entered If the vault code KS is enabled the stable mode output will switch from OFF to ON only after the main code KG is entered followed by the vault code KS command 8 Switching back to the OFF state does not require entering the vault code and is done immediately after the main code KG command 1 or the locking code KZ command 7 is entered After the power supply is connected the electronic lock s outputs operating in stable mode are automatically switched off SYSTEM LED INDICATOR The led SYSTEM is lit when the negative ground of the power supply is connected to the LED connector located on the connector terminal It is not mandatory to utilise this indicator This led can be used for example for indicating that the alarm system is armed Open collector output types such as PREALARM or AUX can control direct the led SYSTEM PREALARM DURESS FUNCTION This function activates the PREALARM transistor output when three consecutive attempts of entering access codes fail or command 2 is used The PREALARM output automatically switches off after 60 seconds A short acoustic signal sequence is generated in addition to activation of the PREALARM output when three consecutive attempts of entering access codes fail The PREALARM DURESS function is usually utilised for signalling keypad manipulation or silent al