Home
F11 Installation Guide
Contents
1. In connecting of the Fingerprint reader 8 shielding cable RVVP 8X0 3MM2 is recommended to reduce the interference in the course of transmission please read and always follow F11 Installation Guide closely Because the wrong wiring will cause the core block and sensor to burn out lead to device breaking down at this cause we are not liable for any damages and troubles 10 12VDC power supply cable by two core power cord RVV 2X2 5MM2 If the distance between power adapters and device is too long please do not use the other type wire for replacement When you select the power wire you should pay attenuation to the voltage decay of long distance transfer 11 Please use specialized RS485 cable the internationally popular RVVP shielded twisted pair is recommended Model RVVP 2x0 5 1 5mm2 two core shielded twisted pair and the active RS232 RS485 converter to connect with the network the bus structure apply to connect with each device When a long cable is used to transfer 2 1 Before Installing signal it is need to connect a matching resistance to each terminal and its value is 1200 12 Signal cable such as RS485 cable and high power electricity cable such as AC electric locking cable can not place in parallel If it is necessary please put them about 50cm away More details please see to the F11 User Manual the appendix the other instructions and so on 1 2 Operation Panel Power Button LED Indic
2. Measure the supply voltage ensure that it is 12VDC Device is unable Cause to connect with The connection problem PC Communication parameters not configure right such as IP address RS232 RS485 baud rate system password etc Measure Check and examine the connection of RS232 RS485 or TCP IP whether its connection 1s correct or not 2 Change the communication mode to connect with PC and check the parameters After the power Cause is on the device For long time used surface of fingerprint sensor cycle reboot becomes dirty or there are some scratches on it the device takes it as a fingerprint and does verification 2 Fingerprint connection cable of fingerprint sensor is loosed 8 Chip on board is broken 22 The sensor light is off fingerprint Wiegand output problems After match fingerprint correctly or swipe card the controller can not accept the card number or numbers error 4 Trouble Shooting 4 Lack of power Measure scotch Under such situation you can use tape to adhere the dirt 2 Need to contact suppler and apply for repair 4 Use a multimeter to measure the power voltage Cause Fingerprint connection cable is broken 2 Fingerprint sensor broke down Measure Please take out the FFC from slot of fingerprint sensor plug it again 2 Contact suppler apply for repair Cause communication distance between fingerprint reader and acc
3. be cut off and use insulating tape to wrap it The delay time of strike lock is adjustable according to different conditions Select electric lock It is better to use electric drop bolt for the two direction opening glass door Both open to inside or outside direction For the single opening wood door in company internal we recommend to use magnetic lock the magnetic lock also be called as electric magnetic lock The magnetic lock is more reliable than the electric drop bolt but the electric drop bolt is much safer than the magnetic lock In the small living community it is better to use electric drop bolt and magnetic force lock The electric control lock gives out higher noise The electric control lock is commonly used to building communication Now there is a soundless electric control lock which is able to be applied Please pay attention the lock is made of iron and easy rust so you must beware of not exposing it to water or harsh condition there are some other electric locks available we don t recommend you to use them Connect with electric lock The Normal Open lock is open when the power is off The Normal Close lock is closed when power is off The device supports both of the two kinds of locks at the same time The way of lock connection changes with the type of lock For NO lock the NO terminal will be used for NC lock the NC terminal will be used When the DC power electrical lock 1s connected to the system you n
4. user can clear the alarm by unlocking the door upon successful verification F11 Installation Guide V1 0 Restore factory defaults The factory defaults can be restored through the tamper switch When the system generates an alarm for 30 60 seconds the user can press the tamper switch three times Till the speaker sounds to restore default settings including the device number system password IP address 485 address and keyboard password Pa Tip The user information stored on device will be cleared after the device is restored to factory defaults please be cautious Tamper Switch 3 3 Embed EM Card Reader Optional Embed a non contact EM card reader module the distance of flashing card is 5 10cm it completely supports the thick card 1 88mm middle card 1 05mm and thin card 0 88mm whose operating frequency is at 125KHz the card sensor area as following illustration 20 3 Other Functions 3 4 Embed MIFARE Card Reader Optional Contain a non contact MIFARE card reader module the distance to detect card is 5 10cm it completely supports MIFARE cards that provide operating frequency 13 56MHZ communication speed 106KBPS the card sensor area is as following illustration Card Sensor Area 21 4 Trouble Shooting 4 Trouble Shooting Power LED is off Cause No power or lack of voltage Measure Check and examine the connection of PWR GND make sure they contact well 2
5. F11 Installation Guide Version 1 0 Date Jul 2010 Table of Contents Table of Contents I Berore Installmoa reliable l Lil NoticeAbodtInstalinS telont ir RAR l b Operation Pane ooer eae aae eat 3 De DYSE OM gura Ona A OEE 5 di sfallationa ELL iii dad Cee tua 5 Sal Device mistallation aalea ani n 5 3 2 Connect with External Equipment aaa 6 3 2 1 Connect to the Access Controller 7 32 L COn ct 10 Alarm lalla 7 3 2 3 Door Lock Connection marano T 3 2 4 Communicationi Modereer a asr E a EP EE 7 3 2 5 Complementary Communications f See OWE CONNGC HONS c a E A 7 Io FIR CCC Davoli T ABET UNC MOM Seii Ee oe 7 AF Reset BONON etina EE T al etwas als 7 AD Tamper owiehe E E ee T 4 3 Built in EM Card Reader Optional iii fi 4 4 Built in MIFARE Card Reader Optional 7 3 AOU NS SNOG N Og iii iaia 7 1 Before Installing 1 Before Installing 1 1 Notice About Installing This device is a mass produced product It strictly tested comply with the standard of China U S A and EU This file contains important information It is better for you to read it carefully prior to use If you ignore it the incorrect installation may cause the unit damage Although we could do our best to offer you service the neglect to the guide could cause unwanted cost for you l Before install
6. ation please make sure the power is cut off because it is very dangerous if the power is on The short circuit of power cable may cause the core parts damage 2 All exposed part of connection wire end cannot be exceeded 5mm to prevent the bared wire accidental connection which leads to device break down And also suggest using different color cable to connect 3 In the place where the static is strong or in winter please connect the grounding firstly in order to prevent the instant mass static damage the device 4 Connect power supply with device in the last for the wiring connection If you find any unusual thing occur please firstly cut off the power then go to examine Keep in mind wiring operation under power on will lead to device sudden damage we are not liable for damages and troubles due to such operation F11 Installation Guide V1 0 5 The height to mount device is about 1 4 1 5 meter 6 After installation please take off protection film on the fingerprint sensor to get best recognize result 7 After installation finish when go to test the exit button please keep a personal in the outside because sometimes the accidental issue can bring on you that you are not able to go outside 8 It is good to use more than 12V 1 5A independent DC power supply for this device It can reduce the electric interference between the device with controller or electric lock current ripple wave is less than 150mV 9
7. ator Fingerprint Sensor Sensor Area 1 Power Button Press and hold the power button for three seconds to turn the power off press and hold the power button one second to turn it on 2 Fingerprint Sensor Used to enroll or match fingerprint and delete user F11 Installation Guide V1 0 3 LED Indicator The LED indicator is used to display device operation enrollment deletion or verification state 4 Card Sensor Area Used to sense the administrator card for management or the ordinary card for enrollment matching and deletion 2 Installation 2 Installation 2 1 Standard Connection There are three modes that the PC software communicate and exchange information with the device RS232 RS485 TCP IP RS485 and TCP IP modes support remote control The standard connection diagram shown below 185A 485 Converter 4R5R Li DI Controller TPIN O Reader Controller TPIN Reader 2 2 Device Installation This product is designed for indoor installation if it has to be installed outdoor please place the equipment in proper surroundings you must beware of not exposing it to water or harsh condition we recommend to embed the cable into the wall if it isn t capable to do you must obtain the user s permission before installing F11 Installation Guide V1 0 1 Post the mounting template on the wall Drill holes Holes for screw and wiring according to the marks on the template 3 Tak
8. e away the screw onthe bottom ot device 4 Release the mounting plate 2 3 Connect with External Equipment To avoid the possible damage to the device before connecting or disconnecting external equipment you should make sure to disconnect the power cable first Please follow the installation guide to connect the external equipment 1 Access Controller 2 Alarm 3 Various network 4 Auxiliary communication interface 2 Installation 5 Power supply Wiring terminal for external equipment shown as below 2 3 1 Connect with Access Controller As a fingerprint reader F11 can not work alone until it connect with the access controller It is only a fingerprint identification device in the system and provide the controller with a standard or self define Wiegand signal Such as others card reader we adopt the standard signal DO DI GND connection mode See Standard Connection Diagram BS Notice Whether the power of F11 supply by the access controller or F11 Installation Guide V1 0 not the two equipment s GND must be in common connection Do not replace Weigand signal GND with power GND To ensure the wiegand signal transfer steady please separately plot wiring si pra U TE Alen WDI EEE es Specifications TDW pulse 400 um TIW cycle 2000 ms Output drive capability 200 mA Definition terminal connection 7 PIN Cable a Terminals Function To T o _ DI T E I I 6 wo Wiegand in
9. eed to parallel one FR 107 diode Equipped in the package to prevent the self inductance EMF affect the system do not reverse the polarities This access control device is powered by DC12V and the work current is 400mA If the lock work electric power is DC12V and the work current is less than 1000mA the fingerprint device and lock are able to be powered by one adapter together please refer to the table 1 2 1 F11 Installation Guide V1 0 In the following three cases we recommend that fingerprint device and lock are powered separately 1 The working voltage of the lock is DC12V but the current difference of the fingerprint device and the lock doesn t exceed 1A 2 The lock voltage is not DC12V 3 The distance between lock and fingerprint device is too far Lock Connection Diagram 1 NC lock connection The device and lock power by one adapter 2 NO lock connection The device and lock power by one adapter 2 Installation 3 NC lock connection The device and lock powered by independent adapters 4 NO lock connection The device and lock powered by independent adapters 2 3 4 Communication Mode The communication line should be as far as possible away from the high voltage wire It should not be parallel with the power cable do not 13 F11 Installation Guide V1 0 bundle them together Terminals Function n a 6 se 3 Ethernet oi 2 RISI 1 RS485 Com
10. ess controller is too long 2 Poor communications environment Access Controllers request fingerprint reader have a stronger signal drive capability Output circuit damage put a multimeter to DC profile and measure WDO WDI pins when verification successful two pins voltage is subject to fluctuations without fluctuations or 0 V the circuit has proved damage Measure Communications distance between fingerprint reader and access controller is no more than 100 meters longer distance need to connect conversion circuit 2 Improve communications environment use a better shielding cable to reduce external interference Modify the WIEGAND output signal of the fingerprint reader adjust the low pulse cycle to 500us adjusted the cycle to 2ms Then add the resistance to offset the access controller s input pull up resistor 4 Contact with the vendor for warranty Failed RS485 Cause communication RS485 communications line connection wrong Communications baud rate is too high In the proposed multiple device networking as 9600 Too long distance of communication or poor environment 4 Among network a RS485 chip of the fingerprint reader damaged that caused the network paralysis Two machines have the same IP address Too many devices over the network will affect the communication distance and the RS485 signal stability RS232 485 converters drive capability no enough Measure 1 The theor
11. inal connection Terminals Function 2 4 Fixed the Device After be sure all cable are inserted correctly into fix installed 17 F11 Installation Guide V1 0 backplane and mount F11 on the backplane 6 Fix the device with the plate 5 Fix the cushion and plate on the wall after all wiring completed BS Note Please strictly in accordance with the definition to connect and connect completed All exposed part of connection wire end cannot be exceeded 5mm to prevent the bared wire accidental connection which leads to device break down in particular the red cable as a 12 V output voltage when there is no an external card reader in any case ensure to cut this cable and use the insulation adhesive plaster to dress it so as to avoid short circuit 3 Other Functions 3 Other Functions 3 1 Reset Button Due to operation error or other accidence which leads the device not to work you can restart device through reset key 1 Take a small tool which diameter is no more than 2mm 2 Find the Reset mark on the left of the small hole at the bottom of device see following figure 3 Use the tool stick into the hole refer to the picture below then the device restart Reset Button 3 2 Tamper Switch The tamper switch is pressed and held down with the rear cover When the device is dismantled the tamper switch will be lifted up and then it will send an signal to trigger an alarm Clear alarm The
12. munication Mode 1 While using RS485 communication mode specified RS485 cable and active RS232 485 converter required bus structure is recommended ABSA 4858 RS485 Bus 102 4998 2 Installation 2 If RS485 communication distance is over 300 meters add a terminal matched resistor with 1200 to RS485 bus See the diagram below add the resistor to 0 and 7 devices R5485 Converter R5485 Bus 2 3 5 Complementary Communications The complementary communications such as Ethernet and RS232 Mode shown below Far Ethernet hinda F11 Installation Guide V1 0 1 Ethernet Mode Connect the device with PC through crossover cable em 2 Ethernet Mode Using the straight cable to connect the device and the PC to the Switch Hub 3 RS232 Mode 2 Installation RXD XD GND PC Series Port 2 3 6 Power Connections F11 power supply is 12VDC standby current about 50mA operating current of about 300mA please use only approved the power adapter the power adapter must be rated for the product and for the voltage and current marked on the product s electrical rating otherwise it will cause serious damage See standard connecting figure Power requirements DC 12V 2V 1A BS Note F11 directly power on through the power supply of the access controller can also be an external sources of power The define of term
13. put 2 Installation ih 17 g n vi 5 2 3 2 Connect to Alarm F11 can connect a alarm signal Alarm to system which mainly use to remind that the F11 has been dismantled No matter what condition when it is removed F11 will trigger alarm output in the power on state otherwise the wire doesn t send any signal F11 will link GND through the wire if the system be triggered follow this principle we can achieve the remind function of dismantled alarm Connect the negative of alarm power to alarm output the positive of alarm power connect to the positive of F11 power See the figure below F11 alarm output only support 12VDC alarm BS Notice There is a tamper switch in the bottom of F11 For details see 3 2 Tamper Switch Alarm connection diagram shown as below F11 Installation Guide V1 0 Alarm Output Alarm Alarm Power NC BS Notice The power output of the alarm is no more than DC12V 2 3 3 Door Lock Connection The way of installing door lock depends on the type of lock and local condition Internal resistor which comes from long distance transfer should be taken into consideration when selecting the cable of electric power The door lock should be installed reliable and stable Ensure the wiring is correct For the strike lock and electromagnetic lock you should pay attention to positive and negative terminal connection The unused 10 2 Installation bare end of wire should
14. y longest distance between fingerprint reader and access controller is 1 200 meters 24 4 Trouble Shooting Actual apply is not recommended more than 500 meters longer distance than add repeaters Communication baud rate adjust to 9600 Add the terminal matched resistance to RS485 bus in the starting terminal and the end terminal resistance is about 120 Q 4 Improve communications surrounding environment use a good shielding cable and smaller distributed capacitance wires to reduce external interference Cut off the power of fingerprint reader one by one to position the failure terminal Reducing the number of machines or increasing RS232 485 converter or RS485 network Recommend to use active RS232 485 converter Information in this document is subject to change without notice Printed in China 26
Download Pdf Manuals