Home

WEBNode MANUAL - Lakewood Instruments

image

Contents

1. 14 5 3 1 3 Search for Device 15 5 3 1 4 Refresh View of Com Ports on the System 16 5 3 1 5 Adding or Removing Com 17 5 3 1 6 Configuring Com Ports for WEBNodes 18 5 3 1 7 Exporting to Com Port Config file 19 5 3 1 8 Importing from a Com Port Config file 20 5 3 1 9 Setting Up WEBNode Email Text Message Alerts 21 5 3 1 10 Sending Email as a Text Message 22 5 3 1 11 The WEBNode Alert 22 5 3 1 12 Verifying the Internet IP 23 5 3 1 13 Controller Communications Settings 23 5 9 Technical SUPPO tisrin aaaea anari aana eea aaa aa aa aaa a aaa a aara E arana gin 24 6 1 2 25 7 0 AW UNOS c T 27 7 1 WEBNode Installation Drawing 1268970 1 28 1 0 Introduction Controller with 1 Relay Node 2 Conductivity Nodes and Drum Level Sensor Connected to Personal Computer The Lakewood Instruments WEBNode is used to connect a model 20
2. Device Tools Help Export to Com Port Config file Import from Com Port Config File Add and Remove Refresh View of Com Ports on the System F5 Com 99 Com 10 1 3 Select the Com Port Config file you wish to import Save Com Port Config File Save CPR 4 Qd rE f Driver 2 Plugins My Recent E _BeforeLastEdit cpc Documents E Lastsaved cpc E ComPorts1 cpc Desktop My Documents My Computer File name v My Network Saveastype Port Config Files cpc y 4 To save the port settings click the Save icon d 20 5 3 1 9 SETTING UP WEBNode EMAIL TEXT MESSAGE ALERTS The 2000 series controllers have the ability to call out on user selected alarm conditions These call outs can be in the form of e mail or text messages with the use of the WEBNode No customer email server or SMTP access is required and no additional set up is required for this function to operate The WEBNode can be custom configured to use SITE specific email servers Contact Lakewood Instruments for additional information The WEBNode ALERT setup screen for the WEBNode is located on the WEBNode homepage and can be accessed by using your web browser This homepage is the IP address of the WEBNode followed by 8080 For example http 168 24 1 14 8080 The homepage contains links to the Lakewood Instruments products pages as well as tables for contact information in case of an alarm OLAKEWO
3. s will require the same porting on a common network The TCP Port number for each WEBNode is printed on the WEBNode serial number label HW Address 4 sema NUMBER PART NUMBER A 1268970 TCP Port Number PORT 10067 4 3 NETWORK CONSIDERATIONS In order for the WEBNode to function via the internet the site must have four items resolved 1 The network or the connection to the network where the WEBNode will reside must have an Internet Service Provider ISP Internet address that is an STATIC IP address This requires that the ISP lock down a specific address Example http 169 256 23 13 that will provide a consistent address for connection purposes Without the STATIC IP the Lakewood Remote Windows Software LRWS and CPR Programs cannot tunnel through the internet to the controller since they will not know where the controller is residing The installation site may already have a static IP if they originate their own homepage or use programs accounting sales engineering that require field personnel to communicate with internal systems If not the customer s ISP may set up a STATIC IP connection for a fee An alternative to the customer attaching a WEBNode and controller to their network is to use the EZWEB Wireless system from Lakewood Instruments This requires no additional infrastructure to support but there is a fee to maintain a wireless Internet connection separate from the customer s system The network mu
4. 5555551234 vtext com See the table below for some common cell carrier domains that are used in the USA Carrier Send Email to phonenumber Alltel message alltel com AT amp T mms att net Nextel messaging nextel com Sprint messaging sprintpcs com SunCom tms suncom com T mobile tmomail net VoiceStream voicestream net Verizon vtext com 5 3 1 11 The WEBNode Alert Message The WEBNode Alert message is an email message that can be sent to up to six email or text message addresses The message can be up to 80 characters in length It is recommended that your message include some kind of an identifier for the controller For example CUSTA Cooling B is in alarm 79 45 56 777 In this example we identified the customer the tower the status and the IP address The email notification will come from webnode lakewoodinstruments com have a subject line of WebNode Alert and will look something like ees 1 eo Ei WebNode Alert Message Plain Text DER i File Edit View Insert Format Tools Actions Help i C Reply All Forward Y SIE X ar A webnode lakewoodinstruments com Sent None ppeacock lakewoodinstruments com Cc Subject WebNode Alert CUSTA Cooling B is in alar n 79 45 56 777 22 5 3 1 12 Verifying the Internet IP Address The WEBNode webpage includes a link to verify your internet IP address At the bottom of the webpage is the CHECK YOUR
5. ID Product 172 18 25 109 1 10001 00 20 4A 9B 0D 1F 1081100 172 18 2 212 1 Unknown 00 30 31 FF FF 48 S6 81632 LC48 172 18 11 230 1 Unknown 00 80 A3 89 42 3D Unknom B1 172 18 0 107 1 Unknown 00 30 31 FF FF 54 86 SLC32 172 18 2 210 1 Unknown D0 80 A3 89 0D 59 5 81 16 172 18 12 200 1 Unknown 00 80 A3 89 0B 6D 7 SLC4B 172 18 2 213 1 Unknown 00 80 A3 89 37 0F 87 SLC48 172 18 23 110 1 Unknown 00 80 3 89 00 87 85 81 16 172 18 19 50 1 Unknown 00 80 A3 89 2D Al 4 SLCOB 172 18 2 217 1 Unknown 00 30 48 5D 57 3E Ml SIM IP Address Internal IP address of the device server to which the com port is connected TCP Port The TCP Port Address assigned at the factory Device Name A user supplied name that identifies the device server Port Name A user supplied name that identifies the port HW Address Hardware address also called MAC or Ethernet address that identifies the unit It is written on the WEBNode label in the format 00 20 4a XX XX XX where the XXs are unique numbers assigned to the WEBNode The HW Address can be used to help identify WEBNodes To name a device server and port 1 In the Device pane right click in the device s row A pop up menu displays 2 Select Name Device and Port The Change Names dialog box displays 3 Enter the Device Name and Port Name and click OK 15 WARNING IT IS HIGHLY RECOMMENDED THAT YOU REFRESH VIEW OF COM PORTS ON THE SYSTEM BEFORE MAKING ANY
6. ISP link With a computer that is connected to the same network as the WEBNode click on this link to verify your internet IP address The IP address that will be shown is the address you would use to access your WEBNode from outside your firewall over the internet http www whatismyip com automation n09230945 asp Microsoft Internet Explorer File Edit View Favorites Tools au il Ar y I as 4 ix Search 57 Favorites Es Gs el 4 3 Address El http www whatismyip com automation n09230945 asp v Ee Links 75 19 65 62 5 3 1 13 Controller Communications Settings The WEBNode is configured to communicate with your Lakewood Instruments 2000 series controller via RS232 with the following settings Baud Rate 19200 Data Bits 8 Parity NONE Stop Bits 1 Your controller must have these settings in the communications screen in order to communicate with a WEBNode 23 6 0 Technical Support If you need technical support for your Lakewood Remote Windows Software Lakewood Instruments Technical Support for the LRWS software and related products can be reached by calling 800 228 0839 or faxing 414 355 3508 Monday through Friday 7 30 a m 5 00 p m Central time NOTE IF YOU CALL FOR TROUBLESHOOTING HELP PLEASE MAKE SURE THAT THE MODEL NUMBER SERIAL NUMBERS AND ANY INFORMATION ABOUT OPTIONS ARE ALL READILY AVAILABLE FOR REFERENCE Mail and returns shoul
7. automatically obtain an IP address in smaller networks that may not have a DHCP server A range of IP addresses from 169 254 0 1 to 169 254 255 1 has been explicitly reserved for AutolP enabled devices The unit automatically selects an address from the AutolP reserved range Then your unit sends out a ARP request to other nodes on the same network to see whether the selected address is being used If the selected address is not in use then the unit uses it for local subnet communication If another device is using the selected IP address the unit selects another address from the AutolP range and reboots After reboot the unit sends out another ARP request to see if the selected address is in use and so on AutolP is not intended to replace DHCP The unit will continue to look for a DHCP server on the network If a DHCP server is found the unit will switch to the DHCP server provided address and reboot Note If a DHCP server is found but it denies the request for an IP address the unit does not attach to the network but waits and retries If the WEBNode will be used for internet communications the network must have a static IP address 4 2 TCP PORT NUMBER Every TCP connection is defined by a destination IP address and a port number A port number is similar to an extension on a phone system Each WEBNode is assigned a specific TCP port number by Lakewood Instruments during manufacture This is to ensure that no two WEBNode
8. with check marks have already been added 2 Doone of the following To select com ports individually select the appropriate checkboxes To add a range of com ports enter the beginning and end of the range to the right of the Check Range button and click the Check Range button To remove a range of com ports enter the beginning and end of the range to the right of the Uncheck Range button and click the Uncheck Range button To select all of the com ports click the Select All button To clear all checkboxes click the Select None button O 121 Com amp 2 Com122 O Com123 Doms O Com124 C Comes 125 Com126 Com67 Comt27 C Com68 Com128 Com s 129 70 Com130 Com131 C Com 2 Com132 Com 3 C Com133 Com134 Com135 Com136 100 Y 10001 4 Djcw5 O C Come C Comss Dan Com137 10000000 8 C 138 Com79 I Com99 Com139 v Com amp 0 Comi00 C Com140 lt Cora ELE 3 Click the OK button The dialog box closes The added com ports display in red and are identified as new The word Modified displays at the bottom of the window Removed com ports that were saved previously have marked for deletion beside their names 4 To save the settings click t
9. 00 series RS2L option card to Ethernet networks using the Transmission Control Protocol TCP and the IP protocol family The WEBNode contains a Web http server that allows presentation of custom content The WEBNode is used with the Com Port Redirector software CPR and Lakewood Remote Windows Software LRWS to access all of the features of a Lakewood Instruments 2000 series controller over the internet or over an intranet The WEBNode can also be used with the EZWeb Wireless option to communicate over the internet using an EVDO Rev A 3G wireless connection The WEBNode can also be used as an RS232 to Ethernet adapter to directly connect to a 2000 series controller with a laptop 2 0 Features Benefits and Specifications 2 1 Features The Lakewood Instruments WEBNode is compatible with ALL existing 2000 series controllers with the RS2L option The WEBNode is Plug and Play with minimal setup for intranet connections and is accessable via the internet through pre assigned ports with firewall access The WEBNode contains built in web server hardware to prevent network port access by un authorized sources The configuration of the WEBNode is stored in non volitile memory and is retained on a loss of power 2 2 Benefits The Lakewood Instruments WEBNode gives you the flexibility to monitor control and receive notices from your 2000e series controllers locally over an TC IP protocol Ethernet network or from anywher
10. 1 Closed Disconnected Com 5 Disconnected Com6 Disconnected Com Disconnected Disconnected Disconnected Com 8 Com 10 Devices IP Address TCP Port Device Name Port Name Hw Address ID Product 172 18 25 109 1 10001 00 20 4A 9B 0D 1F U3 1081100 172 18 18 201 1 Unknown 00 04 23 B4 1D 02 SIM 172 18 11 210 1 Unknown 00 80 A3 89 01 A7 85 SLCl 172 18 18 203 1 Unknown 00 0E 0C 4E 7D B8 172 18 2 212 1 Unknown 00 30 31 FF FF 48 86 SLC32 172 18 21 63 1 Unknown 00 80 A3 89 1E 29 4 SLCOS 172 18 21 61 1 Unknown 00 30 31 FF FF 42 87 SLC48 172 18 11 230 1 Unknown 00 80 A3 89 42 3D Bl Unknown Bl 172 18 0 107 1 Unknown 00 30 31 FF FF 54 86 SLC32 172 18 2 210 1 Unknown 00 80 A3 89 0D 59 5 81 16 172 18 12 200 1 Unknown 00 80 A3 89 0B 6D 87 SLC48 172 18 2 213 1 Unknown 00 80 A3 89 37 0F 7 SLC48 172 18 23 110 1 Unknown 00 80 A3 89 00 87 S5 81016 172 18 19 50 1 Unknown 00 80 A3 89 2D Al S4 SLCOS 172 18 2 217 1 Unknown 00 30 48 50 57 3 The CPR Manager screen is divided into three sections the left pane shows a tree structure of all com ports that are currently configured the right pane shows information about all the com ports that are shown in the left pane and is used to configure a selected com port and the bottom section is used to show a list of device servers with their address information currently on the local network The bottom
11. An Ethernet cable is required and is not supplied with the WEBNode If you are going to direct connect to your computer s Ethernet port and your Ethernet port is not a multi plex port you will need to use a cross over Ethernet cable INSTALLATION Connect the 9 pin DCE connector to the WEBNode Connect the 25 ft telephone cale between the 9 pin DCE connector and the RS2L card located inside the 2000 series controller Connect an Ethernet cable between the WEBNode and a network jack Connect the 9vdc power supply to the WEBNode and plug the power supply into a 120vac wall outlet The WEBNode has indicator lights on the Ethernet jack to indicate the transmission of data 13 5 3 Operation 5 3 1 Configuring CPR for a new WEBNode connection WEBNode is pre configured at the factory for operation with the Lakewood Instruments 2000 series controllers The set up of CPR consists of adding com ports and entering the IP addresses and TCP ports for each WEBNode 5 3 1 1 Start CPR Click on START CPR Manager 9 Select CPR Select CPR Manager EN a geecrt All Programs vr ro v v v v v v v Bw y cosas E77 5 3 1 2 CPR Manager Description Com Port List General Tests IP Address TCP Port ComStatus Network Status Bliwr SwRec TORec Lom 1 172 18 11 190 10001 Closed Disconnected Com 4 Listen Mode Auto 1000
12. CHANGES TO THE CURRENT CPR CONFIGURATIONS OR PROGRAM CONFLICTS DAMAGE TO PROGRAMS MAY OCCUR 5 3 1 4 Refresh View of Com Ports on the System Some programs may reserve some com ports for their own use and if these programs are opened after CPR is opened but before making changes to the CPR configurations program conflicts and or damage to programs may occur To refresh view of com ports on the system 1 Click on COM PORT in the CPR header 2 Click on Refresh View of Com Ports on the System CPR Manager g Device Tools Help Export to Com Port Config File Import From Com Port Config File Add and Remove Refresh View of Com Ports on the System Com 55 Com 10 1 Para 1 3 The current view of the Com Ports will be refreshed and changes to the com port configurations can be safely made 16 5 3 1 5 Adding or Removing Com Ports CPR enables the user to create up to 256 virtual com ports Only the first 252 com ports can be used with the LRWS software Some com ports will be listed as Inaccessible and are greyed out This means that these com ports are already in use by other parts of your computer system and cannot be used by CPR To add or remove a com port 1 Click the Add or Remove icon PA or select Add and Remove from the Com Port menu A window displaying a list of numbered com ports opens Com Ports are added by checking their boxes and removed by unchecking their boxes Com ports
13. LAKEWOOD INSTRUMENTS WEBNode USER S MANUAL 8 352 974 gal 8 352 974 15 57 08 Tue 24 Mar 98 _ Lakewood Controller 1 iof x AREA C off BLOW Helay 5 off Relays Blow 5 gal Per 1 Makeup off RLY2 off Relay C off Relay 10 Feed 0 min 0 sec after MAKE 500 C off RLY3 off Relay 7 Cof Relay 11 Next Feed Time Fri at 11 30 C off RLY4 off Relay 8 off Relay 12 Next Feed Time Alarms and Messages Wed at 04 00 COND HIGH ALARM NO FLOW Main Menu Water Meters Download P Calibration 4 20 mA Outputs Flow Rates Flow Totals ali MAKE 8 352 974 gal Feed Schedule Alarm Callouts BLOW 0 gal Alarms Datalog Flow MAKE Plus BLOW MAKE Minus BLOW Reading IONODE RELAY 1 Online 0 00 21 Lakewood Instruments 7838 North Faulkner Road Milwaukee WI 53224 USA Phone 800 228 0839 Fax 414 355 3508 http www lakewoodinstruments com Lakewood Instruments We thank you for your selection and purchase of an Lakewood Instruments product Please take the time to read and understand this User s Manual paying special attention to the information about INSTALLATION OPERATION and TECHNICAL SUPPORT If in the future any customer or technical support is required we strongly recommend that you contact us for assistance Our Customer Service Department is happy to assist you with all your pro
14. OD INSTRUMENTS IMPROVING y THE ENVIRONMENT WITH E ADVANCED TECHNOLOGY Test Alert Email 4 623455261 3G momeil net 5 m A 2 0 Messag Cooling B is in celer 79 45 56 777 To set the WEBNode for email text message alerts 1 Access the WEBNode ALERT screen for the WEBNode by using your web browser to access device homepage This home page is the IP address followed by 8080 For example http 168 24 1 14 8080 Click on the Use WEBNode Alert when Controller in Alarm check box Enter the email and text message addresses to which you want alarm notifications to be sent Enter the alarm message you want displayed when an alarm occurs for this controller Click the UPDATE button Click on the TEST ALERT button and verify that the alarm message is sent to all addresses Co N ours In order for the unit to send the alert internet access for the network connection that is home to the WEBNode must be established It is possible that the email alert may not be sent if the network has blocked port 25 or common sites like MSN or Yahoo 21 5 3 1 10 Sending Email as a Text Message The WEBNode Alert email can be sent as a text message to a cell phone The major US cellular carriers use the 10 digit number Qcell carrier domain com format for text capable cell phones with a limit of 160 characters in the subject and message body total For example
15. ace Installation With your Lakewood Remote disk in your CD rom drive browse to the Com Port Redirector folder on the LAWS CD rom Doubleclick on the the Setup application This will install CorDotNetCDGen4 1 1 3 The application installation directory defaults to C Program Files CPR unless another folder is selected during the installation process A shortcut to this application is created on the Start Programs menu for CPR Manager and CPR Monitor 12 5 1 3 Installation of Lakewood Remote Windows Software LRWS System Requirements Supported Operating Systems Windows 2000 2000 Server XP 2003 Server or Vista 30MB free hard drive space INSTALLATION With your Lakewood Remote disk in your CD rom drive browse to the LRWS folder and unzip the LAWS application After you have unzipped LRWS run the application install exe and follow the prompts Refer to the LRWS manual for additional information on the installation of the LAWS software 5 2 Hardware Installation Hardware installation consists of connecting the WEBNode to the 2000 series controller connecting the WEBNode to the network and connecting the WEBNode to a power supply The network can be an intranet connection a direct connection to a computer via an Ethernet jack or a connection to an EZWEB Wireless system The WEBNode is supplied with a 9 pin DCE connector a 25 ft telephone cable with RJ11 jacks and a 120vac to 9vdc power supply
16. are not excluded servers respond UDP port 43283 If you are unable to connect to a device server one possible cause is the Firewall on Select Settings Tab port has already been added and can be removed by pressing this button The Firewallis turned OFF 2 3 2 4 port to the Firewall If the button capti 6 7 8 Enter Com Port Information HW Address IP Address TCP Port Device Name Port Name 172 18 25 109 1 00 20 4A 9B 0D 1F 172 18 18 201 1 Unknown 00 04 23 B4 1D 02 Hl SIM 172 18 11 210 1 Unknown 00 80 A3 89 01 A7 S5 SLC16 172 18 18 203 1 Unknown 00 0E 0C 4E 7D B8 Ml 172 18 2 212 1 00 30 31 FF FF 48 2 Enter the following information The Host This is the IP address for the WEBNode This is the internal IP address if the WEBNode will be accessed over an intranet or this is the static IP address if the WEBNode will be accessed over the internet NOTE If your computer will be used to access this WEBNode over the internet and over the local network enter the internal IP address as the first host then enter the internet IP address as the second host CPR will try each in succession to access the WEBNode The TCP Port This is the TCP Port address that is assigned to the WEBNode at the factory 3 To save the port settings click the Save icon Once the com port information is entered Com Port Redirector can be closed and will
17. d be sent to Lakewood Instruments 7838 North Faulkner Road Milwaukee WI 53224 USA When any merchandise is returned to the factory please call and obtain a return goods authorization order RGA number and have the following information available Customer s name address phone and fax numbers shipping and billing e A hard copy purchase order number no exceptions for cases where repairs or parts are required that are not under warranty contact person s name and phone number to call if the equipment is beyond repair or to discuss any other warranty matter e Equipment model and serial numbers e Reason for return e g repair warranty incorrect part etc We will then fax to your attention an RGA form that must accompany the returned item NOTE THE RGA NUMBER MUST BE CLEARLY WRITTEN ON THE OUTSIDE OF THE PACKAGE S BEING RETURNED ANY ITEMS SENT BACK TO THE FACTORY WITHOUT AN RGA NUMBER WILL BE REFUSED AND RETURNED TO SENDER 24 6 1 Troubleshooting Here is a sequence of steps that should be performed to troubleshoot the WEBNode For additional troubleshooting of LRWS please refer to the LRWS manual You can test your LRWS and CPR software on one of our Controllers here at Lakewood Instruments The internet address is 75 19 65 62 The TCP port is 10001 Set up CPR with this address and try to connect using LRWS 6 1 1 Troubleshooting Steps If a connection issue should occur it is recommended tha
18. duct and information requests Lakewood Instruments Customer Service and Technical Support Departments can be reached by calling 800 228 0839 or faxing 414 355 3508 Monday through Friday 7 30 a m 5 00 p m Central time Mail should be sent to Lakewood Instruments 7838 North Faulkner Road Milwaukee WI 53224 USA LAKEWOOD INSTRUMENTS WEBNODE Table of Contents EUM INITOGUCHON RI eI aaa asea 5 2 0 Features Benefits and 6 2 seil es ERR ERA ERR ERA ERE ERA CERA ERA ERE ERA 6 22 Benelli aid 6 E an 6 SANETI A et ee i Pcl cel cca 7 OME qe EE 7 4 1 IP Addresses iii 8 4 2 TCP Porn N mber connexa a 8 4 3 Network Considerati0NS ccccccnnnnnccccncncccccnnnnnnncncnncnnnnnnnnnnnnnnnnnncnnnnnnnnnnnnns 9 De Getting A ar Ar MEL 10 5 1 Software Installation acne 11 5 1 1 Installation of net 12 5 1 2 Installation of Com Port Redirector CPR 12 5 1 3 Installation of Lakewood Remote Windows Software LRWS 13 5 2 Hardware Installation a 13 5 3 OPE cae count D pcc NDS 14 5 3 1 Configuring CPR for a New WEBNode Connection 14 Start OA d dti 14 5 3 1 2 CPR Manager
19. e in the world via the internet The WEBNode removes the RS232 cable length limitations by using Ethernet or TCP IP networks The WEBNode is a self contained web page that is not hosted by a manufacturer NO ACCESS FEES The alarms you choose will trigger either a modem based or internet based alert This allows for timely response to the site for any specific user defined alarm conditions 2 3 Specifications Serial Interface Serial Line Format Modem Control Network Interface Ethernet compatibility Internal Web Server Protocols supported Weight Temperature Relative Humidity Input Power RS232 with a 19200bps baud rate 8 data bits 1 stop bit and parity of none CTS RTS RJ45 Ethernet 10Base T or 100Base TX Auto Sensing Version 2 0 IEEE 802 3 Serves static web pages and JAVA applets TCP IP and HTTP 2 2 Oz Operating Range 40 C to 85 C 40 F to 185 F Operating 596 to 9596 non condensing 9 to 24 VDC 3 0 Contents WEBNode shipment includes a WEBNode a 120 VAC to 9 VDC power adapter a 25 foot RJ11 cable a 9 pin DCE connector and a cd rom that includes the LRWS software CPR software and net Framework software Inspect the shipping carton for obvious external damage Note on the carrier s bill of lading the extent of the damage if any and notify the carrier Save the shipping carton until your WEBNode is started up If shipping damage has occurred call the Lakewood Instrument
20. ephone cable to the RJ11 jack on the 9 pin DCE connector Connect the WEBNode to the network using an Ethernet cable Provide power to the WEBNode using the supplied 9vdc power supply Operation 1 2 SUE Start the CPR program If the WEBNode is attached to an intranet search for WEBNodes that are connected to the network Note the IP addresses and TCP Ports of each WEBNode If you are connecting through the internet you will need to obtain the IP address for each WEBNode from your IT professional Add a Com Port for each WEBNode and configure for the IP address and TCP Port for each WEBNode The TCP Port number for each WEBNode is assigned at the factory and is documented on the serial number tag of the WEBNode Verify the connectivity between Com Port Redirector and each WEBNode Close the CPR program Start the LRWS program Select CONTROLLERS and add a new controller selecting Internet and using the Com Port that was configured in CPR for each WEBNode Connect to the desired controller 10 5 1 Software Installation The use of a WEBNode requires that the following software be installed NET Framework The Microsoft NET Framework version 2 0 x64 redistributable package installs the NET Framework runtime and associated files required to run 64 bit applications developed to target the NET Framework v2 0 The NET Framework version 2 0 x64 improves scalability and performance with improved cach
21. he Save icon 5 3 1 6 CONFIGURING COM PORTS FOR WEBNodes You must configure a new com port before it can be used by the LRWS software A separate Com Port is used for each WEBNode To configure com port settings 1 Click the desired com port in the tree structure in the left pane Select the Settings tab in the right pane ComPort Device Tools Help Settings Com 4 Tests Com 4 amp All Com Ports 3 amp Com 1 10 Windows Port Name Lantronis CPR Port Windows Device Name Device CprDeviced Com Status sed Window s Service Name CprDrvr Network Status Disconnected Reset to Defaults Cancel Edits 7 Buffer Writes Keep checked for better write performance 7 Connection Timeout in seconds Server Reconnect v Timeout Reconnect 0 Reconnect Limit 0 forever No Net Close Listen Mode Add To Firewall TCP Port TCP Keep live Keep live Time msec Keep live Interval msec F 2217 In Tie DTR to DCD DSR always active v Select Com Port i M e cT Service Host WARNING If the Host is on the other side of a router or a remote firewall T then UDP ports 30718 43282 and 43283 may need to be added to the 21 172181190 1000 firewalls exclusion list You may experience trouble opening this com port if 1721825109 10001 these UDP ports
22. ing application deployment and updating with ClickOnce support for the broadest array of browsers and devices with ASP NET 2 0 controls and services and 64 bit support Com Port Redirector CPR Com Port Redirector is a software utility for network enabling software applications that do not have network support Com Port Redirector installs virtual communication COM ports which are redirected over a network to the serial port of a device server Com Port Redirector consists of the following modules e CPR Manager enables you to map com ports to device servers configure and test com ports e CPR Monitor enables you to identify and troubleshoot problems Lakewood Remote Windows Software LRWS Lakewood Remote is a Windows based program that accesses all the features of Lakewood 2000 Series controllers remotely Communication is direct connect via RS 232 or remotely over phone lines with a modem A user selectable password is required to access any feature beyond viewing Lakewood Remote allows access to multiple controllers phone numbers and passwords Using standard Windows format mouse click buttons all features of the controller can be accessed The datalog stored in the controller can be downloaded into a comma delimited file This can be used by Lakewood Graph or imported into other applications such as spreadsheets 11 5 1 1 Installation of net framework Com Port Redirector CPR requires the installation of the
23. net framework program in order to function You may not need to install the net framework program on your PC because it may already be installed A quick way to tell if you need to install the net framework program is to try to install the CPR program If the net framework program is not already installed on your PC the CPR program will fail to install System Requirements Supported Operating Systems Windows Server 2003 Datacenter x64 Edition Windows Server 2003 Enterprise x64 Edition Windows Server 2003 Standard x64 Edition Windows XP 64 bit Required Software Windows Installer 3 0 is required Windows Installer 3 1 or later is recommended IE 5 01 or later You must also be running Microsoft Internet Explorer 5 01 or later for all installations of the NET Framework Disk Space Requirements 280 MB x86 610 MB x64 Important Make sure you have the latest service pack and critical updates for the version of Windows that you are running To find recent security updates visit Windows Update Installation With your Lakewood Remote disk in your CD rom drive browse to the dot net framework folder on the LRWS CD rom Double click on the dotnetfx application This will install NET Framework 5 1 2 Installation of Com Port Redirector CPR System Requirements Supported Operating Systems Windows 2000 2000 Server XP 2003 Server or Vista Required Software Microsoft NET Framework v2 0 30MB free hard drive sp
24. not need to be opened again unless you are adding or removing com ports or changing comport settings 18 5 3 1 7 EXPORTING TO A COM PORT CONFIG FILE Your current CPR com port configurations can be exported to a file for sharing on another computer or for archiving purposes This makes it easy to import your com port configurations to another computer running CPR To export to a com port config file 3 Click on COM PORT in the CPR header 4 Click on Export to Com Port Config File 4 Manager ComPort Device Tools Help q Export to Com Port Config file Import from Com Port Config file Add and Remove Refresh View of Com Ports on the System Com 55 Para 1nn Com 10 1 o ar 3 Save the file as a Com Port Config file Save Com Port Config File Save in CPR p m E Driver 4 Plugins My Recent E _BeforeLastEdit cpc Documents _LastSaved cpc 8 ComPorts1 cpc El Desktop Y My Documents o My Computer E vj My Network Save type Com Port Config Files 5 3 1 8 IMPORTING FROM A COM PORT CONFIG FILE Your current CPR com port configurations can be imported from a file This makes it easy to import your com port configurations to another computer running CPR To import to a com port config file 1 Click on COM PORT in the CPR header 2 Click on Import from Com Port Config File CPR Manager Com Port
25. or further troubleshooting help 25 B Access the WEBNode Front Page 1 Access the WEBNode front page by using your web browser to access the device homepage This home page is the IP address followed by 8080 For example http 168 24 1 14 8080 If this fails contact Lakewood Instruments for further assistance C Check and Verify Your Internet ISP IP Address 1 At the bottom of the WEBNode front page is the CHECK YOUR ISP link Click on this link to verify your internet IP address The IP address that will be shown is the address you would use to access your WEBNode from outside your firewall over the internet Is this a STATIC address To be able to access the WEBNode over the internet a static address is required D Activate and Test the WEBNode Alert Click on the Use WEBNode Alert when Controller in Alarm check box 2 Enter the email and text message addresses to which you want alarm notifications to be sent 3 Enter the alarm message you want displayed when an alarm occurs for this controller 4 Click the UPDATE button 5 Click on the TEST ALERT button and verify that the alarm message is sent to all addresses If PORT 25 is blocked or if YAHOO is blocked this function will not work Contact Lakewood Instruments for further assistance E Set Up and Access the Controller Using LRWS 1 Refer to the LRWS instruction manual for information on the setup and operation of LRWS If this fails verif
26. s Customer Service Department at 800 228 0839 and return the WEBNode to the factory in the original carton 4 0 OVERVIEW The WEBNode is the hardware that is used in conjunction with the Com Port Redirector software program CPR and the Lakewood Instruments Remote Software LRWS to communicate with Lakewood Instruments 2000 series controllers over an intranet or the internet using TCP IP protocol The LRWS software program is a Windows based program that is used to access and control Lakewood Instruments 2000 series controllers The CPR software program is used to create and manage virtual com ports which are redirected over a network to the serial port of a device server The WEBNode contains an Internal Network device server The WEBNode uses the Internet Protocol IP for network communications and the Transmission Control Protocol TCP to assure that no data is lost or duplicated and that everything sent to the connection arrives correctly at the target 7 4 1 IP ADDRESSES Every device connected to an IP network must have a unique IP address This address can be assigned automatically or manually and is used to reference the specific unit The IP address is automatically assigned on DHCP enabled networks when the WEBNode boots up If the WEBNode cannot find a DHCP server and you have not manually assigned an IP address to it the WEBNode will attempt to use AutolP AutolP is an alternative to DHCP that allows hosts to
27. section can be hidden or displayed at the users discretion When ALL COM PORTS is selected in the left pane the Com Port List tab in the right pane lists the existing com ports along with any additional information if available such as the IP address of the device server to which the com port is connected and the TCP port of the device server to which the com port is connected for example 10001 When a single com port is selected in the left pane the right pane will show the current setting of that com port and will allow the user to change these settings The list of internal device servers is displayed by clicking on the magnifying glass 2 in the upper left hand corner of the screen 5 3 1 3 Search for Device Servers Use the search feature to list the device servers currently on your internal network To list device servers 1 Click the Search icon 7 A list of device servers on the local network displays in the bottom pane of the window 2 View the following information about the device server if available Com Port List General Tests All Com Ports 3 Com Port IP Address TCP Pot Com Status Network Status 2217 BfWr SvRec KpAh 172 18 11 190 10001 Closed Disconnected Yes Listen Mode Auto 10001 Closed Disconnected Yes losed Disconnected Closed Disconnected Closed Disconnected Closed Disconnected Closed Disconnected Devices IP Address TCP Port Device Name Port Name HW Address
28. st have port forwarding or Open porting for the ports 30718 and an additional port specific to each individual device found on the serial number tag Port forwarded port 30718 is a tagback port which allows the WEBNode programs to handshake with the originating PC before completing the connection via the secondary port where the data interchange and RS232 communications packages will be exchanged The port from the back of the WEBNode will number from 10001 thru 12000 In order to make changes to the WEBNode webpage from from outside of the firewall port 8080 must be opened It is recommended that port 8080 be closed after changes are made In order to send emails or text message outside of the firewall port 25 outgoing needs to be opened 5 0 Getting Started The following procedure summarizes the steps for using a WEBNode to communicate with a Lakewood Instruments 2000 Series Controller Software Installation 1 If not already installed install net framework 2 0 on each PC that will communicate with the WEBNode Install Com Port Redirector CPR on each PC that will communicate with the WEBNode Install Lakewood Remote Windows Software LRWS on each PC that will communicate with the WEBNode Hardware Installation 1 2 4 9 Connect the 9 pin DCE connector to the WEBNode Connect one end of the telephone cable to the RJ11 jack on the RS2L card inside the controller Connect the other end of the tel
29. struments 7838 North Faulkner Road Milwaukee WI 53224 USA Phone 414 355 2807 Fax 414 355 3508 http www lakewoodinstruments com
30. t troubleshooting be performed at the local network where the WEBNode resides A Test a com port connection to a WEBNode 1 2 3 Open CPR Select the com port in the left pane and click the Com Tests tab in right pane To open a connection click the Open button The current Com Status displays to the right of the Open Close button The com port attempts to connect to the first host server on the Settings tab for the selected Com Port If the connection succeeds Network Status displays the current status between CPR and the WEBNode This should say Connected to the IP address and TCP port of your WEBNoOde i e 192 168 1 55 10001 The bottom left corner of the screen shows the status of the com port If there is an error connecting to the WEBNode there will be a message that states Status of Com Port xxx is in Error and Disconnected If CPR connects to the WEBNode the message will read Status of Com Port xxx is Open and Connected to 192 168 1 55 10001 The bottom right corner of the screen shows that the OPEN CLOSE test is running If the above test fails NOOR OND Verify that the correct IP address has been entered Verify that the correct TCP Port has been entered Verify that the address assigned to the WEBNode is not already in use Verify wiring connections Verify that the WEBNode has power Try removing power from the WEBNode then restoring power to the WEBNode Contact Lakewood Instruments f
31. y the controller communications settings Consult the LRWS manual for troubleshooting information Contact Lakewood Instruments for further assistance 26 7 0 Drawings 27 REVISION REVISION HISTORY _ mem wu uw 27778 RELEASE 10099 PSG 2 19 08 DB 9 MALE ADAPTER LAKEWOOD WEBNODE AC ADAPTER DB9 CABLE ALL INCLUDED IN KIT P N 1268972 RSeL CAR B9 MALE ADA E HUB R t3 RJ45 RJ45 p STANDARD NETWORK CABLE NOTICE ON REPRODUCTIONS THIS DRAWING THE DESIGN AND THE PATENTS IT COVERS ARE THE PROPERTY OF LAKEWOOD INSTRUMENTS LLC THEY ARE LOANED MERELY ON THE BORROWERS EXPRESS AGREEMENT THAT THEY a QWIOQ WILL BE REPRODUCED COPIED LOANED EXHIBITED NOR USED EXCEPT IN THE LIMITED WAY AND THE PRIVATE USE PERMITTED BY WRITTEN CONSENT GIVEN BY THE LENDER TO THE BORROWER INSTRUMENTS DIMENSIONING AND TOLERANCING PER ASME Y 14 5M 1994 L TOLERANCES UNLESS NOTED TITLE a oe INSTALLATION DRAWING LAKEWOOD WEBNODE FINISH 02 19 08 T amp PN a DATE SE 24 1268970 PROJECT ae SCALE SHEET DWG NO LIBRARY VERSION NTS 1 1 1268970 29 For more information call toll free in the USA 800 228 0839 Manufactured in the USA Lakewood In