Home

VIP-2MP computer software user manual

image

Contents

1. TERMEX SZ PRECISION AT THE HEART OF STABILITY VIP 2MP COMPUTER SOFTWARE FOR SETTING USER DEFINED MEASUREMENT MODES User manual VIP 2MP computer software for setting user defined measuring modes User manual TABLE OF CONTENTS INTRODUCTION orsida 3 KOV ROUE o a a e ree ea EDEL 3 Special TSTMS rren aaa EEEO EAEE AEE EROENA 3 SVEM x8 UKE ME erara E EAE E EA 4 Install Run Remove the software ccccccceeccveceeeeuceeevavaeeevavaneevaveneevavaueavananeavarsnvavanenvavanenvananenyas 4 SOWIE MES eC ne tcocdacucemaieanansncineneseanecermnneseneunetaccinecanenrucesanes EE E EEEE 5 Menu bar and WS TUMCHONS soriire a a it 5 List of user defined measurement MOCES ccscsecessesececsenececeeneceseentcesnenrseseearseseearseseeatsaseeares 6 Data OF the selected MOG Ciiscicudincoriedeebliadicatnsandease uataeagoud ie iidatdeadsaveiadadandgand povaderieamabeveiwads 6 Display representation of the density meter ccceceeecseceeeeeeseeeeeeeeeaeeeeeeaeeeeaeaeeeeataesesataeseeanes 7 Basic ODS aUONSerciceracnae nensneascceanemacenncrsaertersccaterareniensccis RA EAEE 7 Connecting density meter tO a computer sssesssssssrnsnsnurnrnnnurnrnnnurnrnnnurnrnnnurnrnnnurnrnnnurnennnnne 7 Adding lt a user defined mode a cicssasercvexcderduacadardoasacarinareabxdusesiaciuaratasieanaiascuexeiatiaasaletionsaeariuess 7 REMOVING a user defined mode ix cisceiscavicexiacsccstccieesicdicnnsteicaceusneinensi eins ceiataneneatarieemeicemen 7 Editin
2. VIP 2MP UC icon on your desktop and the program will appear in your Start menu To run VIP 2MP UC press Start gt All programs gt VIP 2MP UC or double click VIP 2MP UC icon on your desktop To remove the software press Start gt All programs gt VIP 2MP UC gt Uninstall VIP 2MP computer software for setting user defined measuring modes User manual SOFTWARE INTERFACE The main window of VIP 2MP UC software is shown in the picture below The buttons that are responsible for loading or saving your data are located on top of the window area 1 Area 2 contains a list of user defined measurement modes The data of the selected mode is pro vided in area 3 Area 4 represents display of the density meter in current mode Area 5 is a soft ware status which indicates recommendations and tips for users E Vamuc tf Open Save Read Write Function Titles Yalue fip Menu O Large User def OF 00 Unit e g kg m 3 Name Ib ft 3 3 DE 00 EA User defined Digits after decimal point DE 00 OR Aemperature 2 5 6 243E 01 h Min T Max T 20 20 OE 00 al Apply User defined Mode User def p 0 86670 g cm Control manual 54 lb ft Thermostat 20 00 C 20 00 C mmmmmEEEEEA CC Calibration Display view IP 2M Serial number 5 j 1 menu bar 4 display representation of the density meter 2 list of user defined measurement modes 5 status bar 3 data of the sele
3. ata exchange between the density meter and software VIP 2MP UC is realized through USB port SPECIAL TERMS The user of VIP 2MP UC software should be familiar with the basics of operating Mi crosoft Windows such as e managing windows e managing the functions of dialog boxes e operating of keyboard and mouse Otherwise the user should consult Microsoft Windows help system or operating manual Special terms and their meaning Cursor Picture representation of the mouse pointer Move Move the mouse onto the desired object Select Move the mouse onto the desired object and left click Press the key which is indicated inside of the angle brackets to carry out a cer lt ENTER gt tain command VIP 2MP computer software for setting user defined measuring modes User manual SYSTEM REQUIREMENTS Minimum requirements Intel Pentium or processor equivalent to industry standards with 133 MHz or faster 128 MB RAM 5 MB free hard disk space Microsoft WindowsQ XP or newer version Graphics mode 800x600 with 256 colors Mouse or trackpad Recommended requirements Intel Pentium II 256 MB RAM Graphics mode 1024x768 or higher INSTALL RUN REMOVE THE SOFTWARE To install VIP 2MP UC software on your computer complete the following Start file VIP 2MP_UC_setup_vxxx exe xxx number of the version Install the software as recommended by the Wizard Once the software is successfully installed the Wizard will create a
4. ce Adding a user defined mode Press EJ button to add a new user defined mode The list of user defined modes will re flect the new addition Removing a user defined mode To remove a user defined mode e select the desired mode from the list e press LX button The selected mode will be removed Editing a user defined mode To edit a user defined mode e select the mode from the list e fill in fields 1 9 with desired values e press Apply button to save changes VIP 2MP computer software for setting user defined measuring modes User manual Saving a user defined mode To save a user defined mode e press save e in the dialog box select folder and name of the file type will be selected automatically e press lt ENTER gt or Save button Press lt ESC gt or Cancel button to cancel Opening a file To open a file e press ae r e in the dialog box select folder and name of the file e press lt ENTER gt or Open button Press lt ESC gt or Cancel button to cancel e Before opening a file all the current data will be erased Reading a user defined mode F Read To read user defined modes from the memory of the density meter press The number of the transferred modes will be reflected in the status bar Writing a user defined mode To write a user defined measurement mode into the memory of the density meter e in write e inthe dialog box press OK button e when the operatio
5. cted mode Menu bar and its functions i Open Opens a file with user defined modes previously saved on your computer lel Save Saves the data on your computer Read Reads user defined modes from the memory of density meter Available only when the density meter is connected to the computer 4 write Writes user defined modes into the memory of density meter Available only when the density meter is connected to the computer VIP 2MP computer software for setting user defined measuring modes User manual List of user defined measurement modes 1 button to add a new user defined mode 2 button to delete selected mode 3 selected mode 4 empty spaces to add new user defined measurement modes Data of the selected mode Function Titles Yalue f p lc Ctarge 5 User def i 0E 00 pay z Unit e g kg m 3 ame lb ft 3 6 OE 00 p User defined 3 gt Digits after decima n DE 00 P Temperature F 6 243E 0 ply Min T Max T DE 00 p ai C4 1 polynomial coefficients 2 short title of user defined mode displays in density meter main menu 3 full title of user defined mode displays in density meter basic mode 4 temperature range which defines the measurement mode When the mode is set to only one temperature the values should match 5 show value large 6 measuring unit of the mode 7 button to add cube symbol to the measuring unit 8 button to add degree symbol to th
6. e measuring unit 9 number of digits after the decimal point 10 button to apply the changes in fields 1 9 VIP 2MP computer software for setting user defined measuring modes User manual Display representation of the density meter Display view User defined b Mode User def p sai g cm Control manual 3 54 1 1 lb ft Thermostat 20 00 C 20 00 C SERS Calibration 1 value calculated according to polynomial coefficients defined by a user 2 polynomial argument BASIC OPERATIONS Connecting density meter to a computer To connect density meter to a computer e Turn the density meter on e Connect the density meter to a computer by means of a USB cable from our delivery package When connecting the density meter to your computer for the first time a message found new hardware will appear on the bottom of the screen Then the operating system will automati cally load all the necessary drivers The message will not appear the following times When the density meter is being connected to the computer for the first time and VIP 2MP UC software is running the operating system might request to restart the computer This pro cedure is not necessary so the request can be declined by pressing No To prevent the sys tem from this message start VIP 2MP UC after connecting the density meter to your comput er After connecting the density meter to the computer the status bar will indicate a serial number of the devi
7. g a user defined mode ssssseeeeeeee tekst ERE E LEE ieee iss ea es 7 Saving a user defined MOUS ane REE AKATE TNA 8 opening aiie easain aaa alaa aa aa aaa 8 Reading a userdenned MOdE sirrini enia A OET OONO ATOTO 8 Writing a user defined mode s ssssssssssssrurnrenrurnrnnrurnsnnrurnrnnnuensnnnunnnunnurnsnnnurnrnnnurnennnurnnnne 8 Operating the SOWA E ar UGE EL eia iaa VNA NNa AEV N iaa 8 N ESEE TIPE PEIE A T E E T TEE T T T A EAT 9 VIP 2MP computer software for setting user defined measuring modes User manual This manual provides the information needed to operate Microsoft Windows computer software VIP 2MP UC for setting user defined measuring modes of digital density meter VIP 2MP INTRODUCTION User defined measurement mode is a data set which transforms measured density into a value associated with the density through the functional dependence of the form f p c4 p c3 p c2 p c1 p cO where c0 c4 polynomial coefficients defined by user p measured density g mL The density meters support up to 5 measurement modes defined by a user KEY FEATURES Software VIP 2MP UC is intended for operation of user defined measurement modes The software allows you to e create and edit user defined measurement modes e save user defined measurement modes to your hard drive e view user defined measurement modes on the density meter e save user defined measurement modes into the density meter D
8. n is completed a message Data writing completed successfully will appear in the status bar If an error occurred a message Error while data writing will appear e Data that is being saved replaces the current data in the memory of the density meter OPERATING THE SOFTWARE add and edit a new user defined measurement mode save the data on the hard disk connect the density meter to your computer save the data in the memory of the density meter restart the density meter 7o apply the newly saved data the density meter must be restarted To restart the density meter disconnect the density meter from the computer turn the density meter off wait for about 5 seconds turn the density meter back on VIP 2MP computer software for setting user defined measuring modes User manual TIPS When it is necessary to change one or more user defined measurement modes in the den sity meter which already contains a few modes transfer the data to your computer make the changes and save the data to prevent the density meter from losing data We also recommend constantly saving the data of user defined measurement modes in your computer

Download Pdf Manuals

image

Related Search

Related Contents

Samsung CL29Z7H User's Manual  Samsung 19" Företagsmonitor med avancerad ergonomi Bruksanvisning  カタログPDFをダウンロードする  MANUAL DO USUÁRIO  DeWalt DW071 Laser Level User Manual  Tristar MX-4143 food processor      Mode d`emploi  EVO+ sw5.0 Start new project short guide  

Copyright © All rights reserved.
Failed to retrieve file