Home
SIMADYN D Digital Control System Interface board SU11
Contents
1. Process signals in a voltage range of 60V and a current range of 0 5A are permissible The transfer board can be used with the SIMADYN D specific system boards according to the following overview EA12 X5 SC11 SC12 EM11 X6 EM13 X6 5 Technical data INSULATION GROUP acc to VDE 0160 Draft came into force 12 90 60V DC rated insulation voltage AMBIENT TEMPERATURE 0 to 55 C STORAGE TEMEPRATURE 40 to 70 C HUMIDITY RATING acc to DIN 40040 F DEGREE OF PROTECTION acc to DIN 400501P00 MECHANICAL STRESSING acc to SN 29010 Class 12 MOUNTING SYSTEM Can be snapped onto mounting rails DIMENSIONS 118mm 135mm 42mm WEIGHT approx 2809 PROCESS SIGNAL VOLTAGE 60V 0 5A Siemens AG Dk Nr 287140 Edition 05 95 3 SIMADYN D Hardware User Manual Connector assignment 6 Connector assignment The terminals numbers of X2 are identical with the ribbon cable connector numbering X1 according to the way the pins are numbered 6 1 Assignment of flat connector X1 terminal block X2 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 Channel 8 Channel 9 Channel 10 Channel 11 Channel 12 Channel 13 Channel 14 Channel 15 Channel 16 Channel 17 Channel 18 Channel 19 Channel 20 4 Edition 05 95 Siemens AG Dk Nr 287140 SIMADVN D Hardware User Manual 7 Attachments 7 1 Overview diagram er a A A A gt SIMADYN D SU11 6DD1681 0EB1 20 pin ter
2. aa tant 5 8 ECB INStTUCIONS sk rel ER Rene io te 6 Siemens AG Dk Nr 287140 Edition 05 95 SIMADVN D Hardware User Manual Warning information Edition 05 95 Siemens AG Dk Nr 287140 SIMADVN D Hardware User Manual Warning information NOTEI The information in this Manual does not purport to cover all details or variations in equipment nor to provide for everv possible contingencv to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficientiv for the purchaser s purposes please contact vour local Siemens office Further the contents of this Manual shall not become a part of or modifv anv prior or existing agreement committment or relationship The sales contract contains the entire obligation of Siemens The warrantv contained in the contract between the parties is the sole warrantv of Siemens Anv statements contained herein do not create new warranties nor modifv the existing warrantv Warning information WARNINGI Electrical equipment has components which are at dangerous voltage levels If these instructions are not strictly adhered to severe bodily injury and material damage can result Only appropriately qualified personnel may work on this equipment or in its vicinity This personnel must be completely knowledgeable about all the warnings and service measures according to this User Manual The su
3. User Manual ECB instructions Siemens AG Dk Nr 287140 Edition 05 95 7 SIMADYN D Hardware User Manual ECB instructions Drives and Standard Products Motors and Drives Systems Group Postfach 3269 D 91050 Erlangen System Based Technology 8 Edition 05 95 Siemens AG Dk Nr 287140 SIMADYN D Hardware User Manual
4. SIMADVN D User Manual Digital Control Svstem Interface board SU11 Edition 05 95 DK Nr 287140 User Manual Interface board SU11 Interface board SU11 11 93 Interface board SU11 09 94 Interface board SU11 05 95 Copying of this document and giving it to others and the use or communication of the contents thereof is forbidden without express authority Offenders are liable to the payment of damages All rights are reserved in the event of the grant of a patent or the registration of a utilitv model or design We have checked the contents of this Manual to ensure that they coincide with the described hardware and software However deviations cannot be completely ruled out so we cannot guarantee complete conformance However the information in this document is regularly checked and the necessary corrections included in subsequent editions We are thankful for any recommendations or suggestions Contents Contents Warnin iinformatio ni nissen eis Hierin 1 1 Ordering information tad 3 2 EFUnCton descriptions tn een enr Alt HH 3 ABONA A At ee AN A 3 4 Application Informatica a HEBT ta nt nt 3 bu Technical dat idi A dieti ib GA a a Al ata Al tee An A an NA E 3 6 Gonnector ASA Md Ass nn dt ete le ne ae nn fete ce 4 6 1 Assignment of flat connector X1 terminal block X2 4 7 Attachments sms fa AE tat ta tuta 5 Ac OVernview diagram ns a et a 5 12 DIMENSION drawing ebda A a Ta l L
5. ccessful and safe operation of this equipment is dependent on prope handling installation operation and maintenance Siemens AG Dk Nr 287140 Edition 05 95 1 SIMADYN D Hardware User Manual Warning information Definitions x QUALIFIED PERSONNEL For the purpose of this User Manual and product labels a Qualified person is someone who is familiar with the installation mounting start up and operation of the equipment and the hazards involved He or she must have the following qualifications 1 Trained and authorized to energize de energize clear ground and tag circuits and equipment in accordance with established safety procedures 2 Trained in the proper care and use of protective equipment in accordance with established safety procedures 3 Trained in rendering first aid DANGER For the purpose of this User Manual and product labels Danger indicates death severe personal injury and or substantial property damage will result if proper precautions are not taken WARNING For the purpose of this User Manual and product labels Warning indicates death severe personal injury or property damage can result if proper precautions are not taken CAUTION For the purpose of this User Manual and product labels Caution indicates that minor personal injury or material damage can result if proper precautions are not taken NOTE For the purpose of this User Manual Note indicates information about the produ
6. ct or the respective part of the User Manual which is essential to highlight CAUTION This board contains components which can be destroyed by electrostati discharge Prior to touching any electronics board your body must be electrically discharged This can be simply done by touching a conductive grounded object immediately beforehand e g bare metal cabinet components socket protective conductor contact WARNING Hazardous voltages are present in this electrical equipment during operation Non observance of the safety instructions can result in severe personal injury or property damage It is especially important that the warning information in all of the relevant Operating Instructions are strictly observed 2 Edition 05 95 Siemens AG Dk Nr 287140 SIMADYN D Hardware User Manual Ordering information 1 Ordering information SU11 6DD 1681 OEA1 2 Function description Using the SU11 interface board 20 pin terminal block conditioned binary analog SIMADYN D process signals are connected through to the SIMADYN D specific system boards by changing over from terminal connection to ribbon cable connection The process signals are connected through without any additional signal processing 3 Board design 20 pin transfer board which can be snapped onto a mounting rail 20 terminals X2 for process signals 4 terminal connections X2 unassigned 2 10 pin ribbon cable connector X1 4 Application information
7. min Overview diagram 7 2 Dimension drawing Dimension drawing Siemens AG Dk Nr 287140 Edition 05 95 SIMADYN D Hardware User Manual Attachments 3SE 465 681 9040 10 MB ECB instructions 8 ECB instructions Components which can be destroyed by electrostatic discharge ECB Generally electronic boards should only be touched when absolutely necessary The human body must be electrically discharged before touching an electronic board This can be simply done by touching a conductive grounded object directly beforehand e g bare metal cubicle components socket outlet protective conductor contact Boards must not come into contact with highly insulating materials e g plastic foils insulated desktops articles of clothing manufactured from man made fibers Boards must only be placed on conductive surfaces When soldering the soldering iron tip must be grounded Boards and components should only be stored and transported in conductive packaging e g metalized plastic boxes metal containers If the packing material is not conductive the boards must be wrapped with a conductive packing material e g conductive foam rubber or household aluminum foil The necessary ECB protective measures are clearly shown in the following diagram a Conductive floor surface d ECB overall b ECB table e ECB chain c ECB shoes f Cubicle ground connection 6 Edition 05 95 Siemens AG Dk Nr 287140 SIMADVN D Hardware
Download Pdf Manuals
Related Search
Related Contents
Accessory Power PowerUP DC User Manual - LTT 取扱説明書 Aube Technologies TH109PLUS User's Manual PDFファイル/1.83MB DUCATISPORTTOURING ELF User Manual Samsung SUHD TV з діагоналлю 55" Copyright © All rights reserved.