Home

PLEASE READ FIRST

image

Contents

1. PLEASE READ FIRST AIR O SWISS amp Finding the ideal location for your The unit should be placed in an The mist outlet must not be pointed WARNING Do not remove the unit Do not place the humidifier elevated position e g on a table directly at plants or other objects water tank during operation Switch directly next to a heating or air vent chest etc at least 3 ft off the floor Keep a distance of at least 20 in off the unit first Place the Hydro ie it away from doors or win ches 50cm Cell in the water tank of the unit OWS Soak the demineralization cartridge in a water bath 24 hours before the first use the resin has to absorb water to reach maximum performance WARNING If the cartridge is soaked in the tank make sure to exchange the water and empty the water from the base before using the humidifier Take off the water tank cap to fill Fill the tank with clean cold water Do not pour water into the mist Close the cap of the water tank Insert the plug into the socket and the tank with water from the tap outlet of the appliance securely place the water tank onto switch on the appliance using the the base The water is now running On Off button from the tank into the base The red empty indicator light may stay illuminated for some seconds until the base is filled with water QUICK OPERATION DESCRIPTION 7144 On Off Button Mist output indicator LO ME HI Hygros
2. eds to be replaced before using the unit e Exchange the demineralization cartridge after 1 2 months when you use very hard water for softer water after 2 3 months No matter how hard your water is exchange the cartridge at the very latest after 6 months e Don t use water from a pre installed water softener or sodium instead of calcium will be emitted from the unit Use distilled water instead and remove the demineralization cartridge e For very hard water areas use only distilled water and remove the demineralization cartridge e Use reverse osmosis water R O water instead of distilled water and remove the demineralization cartridge Cleaning light is on Switch off the unit and unplug it Empty the water in the base Rinse the base with hot clean water Do not sub merge the base Visually inspect the base for dirt or mineral build up If soft water is used decalcifying the unit every 4 Max IL Max 0 5L 320z HOT 140z HOT AlR O SWISSH Switch off the appliance and For best results use EZCal and Do not submerge base in water The unplug it from the socket before EZCal Pro custom cleaning agents cleaning indicator still appears on the cleaning it Clean the water tank to remove deposits from the humidi display after cleaning To reset hold and the base regularly Use water fier base Do NOT run the unit when down the ON OFF button until the only no detergents using EZCal and EZCal Pro This clean light st
3. ops flashing Thoroughly can cause damage to the product rinse the base with tap water and and voids the warranty make sure no EZCal and EZ Cal Pro residues remains in the base There is a sample of EZCal included in the packaging of your humidifier Only use 1 packet for 320z of water Do not change the ratio Thoroughly rinse the base with tap water and make sure no EZCal residue remains in the base Instructions for use are on the packet Please note EZCal and EZCal Pro are the only recommended cleaning and descaling solution Do NOT use any other cleaning solutions since it can damage the product Any use of cleaning solutions apart from EZCal and EZCal Pro will void the warranty EZCal and EZCal Pro descaling agents are available at selected retail stores and online at www airoswiss net TROUBLE SHOOTING Humidity level is not changing or does not reach the desired humidity level e If the water tank needs refilling more than once per day the unit is working properly and the climatic condition in the room has an influence on the humidity Reasons for low humidity level e air circulation is very high air is fully exchanged several times per day the humidifier needs to starts its work from scratch e insulation of home see air circulation e open space with high ceilings not only the footage of the room counts but also the height high rise buildings require more humidification e open windows works similar to air circ
4. ow them away Used granules must go in the waste ACCESSORIES Do I need to keep any parts before I replace the weeks with EZCal and EZCal Pro is suggested If hard water No mist unit is not working empty indicator demineralization cartridge is used the unit should be decalcified every 2 weeks Do not keeps flashing e Yes always keep the water tank cap this is the piece that forget to reset the cleaning light afterwards e Fill up the water tank Check to see if water is flowing attaches the demineralization cartridge to the water tank through the demineralization cartridge attached to the Reset cleaning light water tank cap If the water tank is full but there is only litle What is the Hydro Cell and how long is it e The cleaning light does not automatically reset Hold down water in the base it indicates that the water is now flowing good for the On Off button button A in instruction manual until the through the demineralization cartridge e The Hydro Cell keeps humidifiers operating at their highest light disappears The light automatically comes on approx e Wait for 15 minutes to allow the mist to come out of the unit level between recommended cleaning Good for approxi 14 days after of plugging in the unit e If the unit is not working and the empty light is not flashing mately one to two months depending on the water quality you might have set the desired humidity too low and the the Hydro Cell ensures the humidifier s functionali
5. roswiss net for further information 37519 02
6. tat setting the humidity level Pre heating indicator Timer Automatic mode indicator Sleep mode indicator Empty indicator Cleaning indicator Mist output regulating mist output Operation with pre heating warm mist Automatic mode and Sleep mode Timer indicator 1 8h or CO onmgn nwD SrAC tr Water Quality Maintenance The Hydro Cell keeps humidifiers operating at their highest level between recommended cleanings Good for approximately one to two months depending on the water quality the Hydro Cell ensures the humidifier s functionality while providing fresh humidification performance Refer to the user manual for proper cleaning instructions DO NOT DISCARD Safe for future reference Please read the manual or check our website www airoswiss net for further information FURTHER INFORMATION RECOMMENDED TO CLEAN WITH EZCal AND EZCal PRO AIR O SWISS ADVANCED AIR TREATMENT SYSTEMS What is EZCal and EZCal Pro EZCal and EZCal Pro are cleaning and descaling agents recommended for all humidifiers The decalcification ingre dients cleans the mineral build up in the humidifier base White dust is emitted from the unit White dust particles are minerals that are broken up in tiny pieces by the ultrasonic process Solve the problem e Soak the demineralization cartridge in a bowl of water for a minimum of 24 hours If the cartridge is soaked in the water tank the water in the tank and the base ne
7. ty while Use of distilled water current humidity level in the room is higher That is why the providing fresh humidification performance It needs to be e For best results with your ultrasonic humidifier use distilled unit switches off automatically replaced every one to two months water and remove the demineralization cartridge e Ifthe empty indicator keeps flashing and the tank is full the water is not flowing through the cartridge Exchange the Refer to the user manual for proper cleaning instructions The hygrometer on unit reads a different humidity cartridge or the granules in the cartridge after 2 3 months Depending on the water quality level than external hygrometer in areas with hard water exchange the cartridge after 1 2 e Not all hygrometers are calibrated the same and most are months However the demineralization cartridge and or the Placement of the Hydro Cell off by 5 Plus the humidity level is not the same in the granules must be exchanged at the latest after 6 months or Please see the instruction manual for detailed placement of whole room The air circulation and temperature are diffe the unit does not reach its full performance anymore the Hydro Cell rent in every corner of the room and may affect the humidity level The unit should not be placed near a heat vent or a radiator as the heat will absorb all of the moisture DO NOT DISCARD Safe for future reference Please read the manual or check our website www ai
8. ulation if it is very cold outside don t open the window more than 2 times per day for 3 minutes e big difference between outside temperature and inside temperature the colder the air the less moisture it is capable of holding The more the air is heated up the lower the percentage of relative humidity the amount of water vapor in the air compared to the amount the air could hold if it was totally saturated e position of the unit if it is placed close to a door window or air vent This increases the air circulation If the granules are new see the following instructions Make sure the cartridge and or granules were soaked for 24 hours dry granules take even longer for water to filter through the cartridge and into the base Next please remove a tablespoon of granules from the cartridge and throw them away When there are too many granules in the cartridge it does not allow water to flow from the tank to the base Unit is running intermittently How long has it been since the contents of the cartridge were replaced If 2 3 months have passed it is time to replace the contents of the cartridge However the demine ralization cartridge and or the granules must be exchanged at the latest after 6 months or the unit does not reach its full performance anymore If the contents of the cartridge were just replaced there are probably too many granules in the cartridge Remove a tablespoon of granules from the cartridge and thr

Download Pdf Manuals

image

Related Search

Related Contents

    User Manual - Projector Central  Shrink-Wrap Licenses of Mass Marketed Software  Weider WEBE1038 User's Manual  車両情報ユニット DROP−006 取扱説明書  取付・取扱説明書  Manuale di installazione ed istruzione d`uso per  Whirlpool LA5380XS User's Manual  

Copyright © All rights reserved.