YELLOW JACKET ® - RW Refrigeration Wholesale Ltd

image

Contents

1. Response Time feature takes the guesswork out of whether or not to repair a small leak Unlike the more traditional LED bar graphs that copy or mimic the audio alarm signal the SmartAlarm digital leak size indicator measures registers and displays the leak size independently from both the audio alarm and the sensitivity level The ACCUPROBE UV also features a 3 LED UV light system that works with 395 415nm wavelength leak tracing dyes The sleek ergo nomic design of these YELLOW JACKET leak detectors makes them easy to use in close areas and extendable into hard to reach areas e Automatic calibration and reset to ambient e Detects HFC HCFC and CFC refrigerants see page 6 e Long life stable sensor utilizing Heated Electrochemical Sensor HES technology e 3 selectable sensitivity level settings e Sleek ergonomic design e Low battery indicator e Temp Range 24 to 125 F 4 to 52 C e Humidity 0 to 95 RH noncondensing e SAE J2791Certified e CE Marked e True mechanical pump Parts and Controls ri CN UV LEDs J 0 Digital SmartAlarm UV LED Sensitivity adjust select Power ON OFF JUDE Power ON OFF A Audio mute L a I i 7 Heated sensor Tr i H Fisting LED i ee E _ Flexible probe I A C adapter jack AccuProbe UV Tip AccuProbe UV Battery Installation AccuProbe UV Loosen battery door screw located on the bottom of the detector a
2. or distributor If the sensor is not working correctly the AccuProbe Leak Detector will not come out of the warm up mode Some competitive units without this function will not alert you that the sensor is malfunctioning or has failed Sensor replacement Remove sensor by pulling out of socket Install the new sensor by aligning the notch in the sensor cover with the raised keyway on the sensor socket holder see Figure 2 If the AccuProbe detector does not come out of warm up first be sure the sensor is plugged in all the way If that does not correct the situa tion replace the sensor Note Do not force sensor into socket Misalignment can damage the sensor pins Push straight on do not twist to install sensor Unscrew tip to replace filter Filter Keyway alignment Pull straight out do not twist to remove sensor Figure 2 Partial list of detectable SNAP listed refrigerants R 12 ALTERNATIVES R 22 ALTERNATIVES R 134a R 401A MP 39 R 401B MP 66 R 401C MP 52 R R 407C R 410A R 410B R 507 406A GHG R 414A GHG X4 R 414B Hot Shot R 416A Frig C FR 12 R 113 R 13B amp R 503 ALTERNATIVES R 409A FX 56 Freeze 12 Free Zone GHG X5 GHG HP R 403B R 508A R 508B IKON 12 R 502 R 500 ALTERNATIVES HC REFRIGERANTS not SNAP approved R 402A amp B R 404A R 407A R 408A R 411A amp B R 507 R 290 R 600A R 170 R 290 R 600A R 290 SNAP Significant New Alternatives Program an
3. light is necessary please use UV filtered glasses to avoid damage by the UV light Z CAUTION ULTRAVIOLET LIGHT HAZARD Use with UV shield or wear eye and face protection Before leak checking with the UV light a Make sure the A C system is properly charged with sufficient dye see manufacturer s specifi cations for proper dye charge b Run the A C system long enough to thoroughly mix and circulate the dye with the refrigerant and lubricating oil 1 Turn on UV light by pressing the UV light ON OFF button see diagram on left 2 Holding the leak detector approximately 10 to 14 away shine the UV light beam slowly over the components hoses and metal lines that make up the A C system When the UV light shines on the fluorescent dye that has escaped from the system the dye will glow a bright yellow green 4 The UV LEDs will automatically turn off after five minutes 3 UV LED Lights Using the SmartAlarm Display 1 The SmartAlarm will not display a num ber 1 through 9 until a leak is sensed Once a leak is sensed the numbers on the display will gradually increase 2 Use the SmartAlarm display to Zero in on the leak source by watching the num bers climb higher as the leak source is approached 3 Once the leak source has been located always wait for the maximum number to be displayed to determine the size of the leak 4 Lower numbers approximately 1 to 3 indicate that the l
4. EPA program for ozone depleting refrigerants for mobile and stationary A C systems Replacement Parts Parts kit sensor filters and leak standard bottle 69383 AccuProbe UV Sensor and filter 69384 and AccuProbe Il Sensor filters package of 5 69385 Leak standard bottle 69386 A C Adapter Input 115V 60Hz UL listed 69380 A C Adapter EU UK Plug Input 230V 50Hz 69381 CE amp TUV Approved AccuProbe UV A C Adapter AU NZ Plug Input 230V 50Hz 69378 CE amp TUV Approved Carrying case blow molded with inserts 69387 AccuProbe Il Carrying pouch 69361 Troubleshooting Guide PROBLEM CHECK REPAIR OR REPLACE No power e Check for weak or reversed e Replace batteries batteries Stays in warm up e Sensor not plugged into socket e Make sure sensor is pushed all the mode correctly way down into socket Sensor open defective e Replace sensor No detection Check sensor with leak standard e Replace sensor bottle Check if the filter is dirty or sensor e Replace filter or clean out opening opening is plugged Slow recovery after e Check if filter is dirty or sensor e Replace filter or clean out opening detection opening is plugged No beeping e Nothing e Press mute button if equipped to turn speaker back on Certified to the European Standard EN 14624 Section 13 Minimum sensitivity R 134a fixed position 1 gram year Maximum sensitivity R 134a fixed position gt 50 gram year romsa 18 MONTH LIMITED WARRANTY Rit
5. YE LLOW eh Sea VER Bloomington MN 55438 2623 M Ve 31 www yellowjacket com Telephone 800 769 8370 or 952 943 1333 Fax 800 322 8684 or 952 943 1605 EOM a E mail custserv yellowjacket com COMPANY INC Web www yellowjacket com Copyright 2006 2010 Printed in U S A P N 400399 Rev A
6. YELLOW JACKET ACCUPROBE UV and ACCUPROBE II Refrigerant Leak Detector with Heated Sensor Instruction and Operation Manual Models 69336 69337 69338 69339 and 69354 YELLOW C JACKET RITCHIE Design Certified to meet psiapi SAE J2791 for R 134a Made in U S A Introduction The YELLOW JACKET ACCUPROBE UV and ACCUPROBE II Hand held Leak Detec tors detect all HCFC refrigerants such as R 22 and R 124 The ultra sensitive long life sensor with exclusive Heated Electrochemical Sensor Technology HES also detects the more cur rent difficult to detect HFC refrigerants such as R 134a R 404A R 407C and R 410A see page 6 for a more complete chart of detectable refrigerants The ACCUPROBE UV is equipped with the unique digital SmartAlarm LED display the first digital leak size indicator in a hand held heated sensor leak detector This Features e Advanced digital SmartAlarm leak size indicator AccuProbe UV e Flashing visual alarm indicator at probe end AccuProbe UV e Audio mute button AccuProbe UV e Operates on 4 AA alkaline batteries AccuProbe UV can also use AC power e 3 LED UV light system that works with 395 415nm wavelength leak tracing dyes AccuProbe UV e Microcontroller technology e Ultra high sensitivity to detect 0 06 oz 1 7g yr of R 134a and 0 03 oz 0 9g yr of R 22 Sensitivity Power Probe Length Calibration Sensor Life Length body Weight Battery Life
7. chie Engineering guarantees YELLOW date of sale ACCUPROBE leak detectors have a JACKET AccuProbe Leak Detectors to be free of date of manufacture serial number located on the defective material and workmanship that would label on the bottom of the unit affect the life of the product under normal use for the purpose for which it was Correction in the manner provided above shall designed This warranty does not cover items that constitute a fulfillment of all liabilities with have been altered abused misused improperly respect to the quality material and workmanship maintained or returned solely in need of field of the product service maintenance This warranty excludes the sensor which is warranted for one year THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER If found defective we will upon compliance with WARRANTIES OF QUALITY WHETHER the following instructions credit replace or WRITTEN ORAL OR IMPLIED repair at our option the defective leak detector provided it is returned within 18 months of the Cross Sensitivity to Automotive Chemicals Some automotive solvents and chemicals have similar hydrocarbon properties as R 134a and may elicit a positive response lt 30 seconds from the AccuProbe Before leak checking clean up any chemicals in the list below that elicit a positive response YELLOW JACKET Products Division For tips on searchin Ritchie Engineering Co Inc f k wi 8 10950 Hampshire Avenue South
8. eak size is less than 0 1 oz yr and may not require repairing at this time depending on the amount of gas in system NOTE Multiple small leaks in a system are cumulative and may require that all system leaks should be repaired AccuProbe II 1 TURN ON Press the ON OFF button once to turn on and again to turn off 2 WARM UP The detector automatically starts heating the sensor During the heat ing cycle the detector will sound a slow beep Warm up is generally less than 20 seconds 3 READY The detector is ready to begin searching for leaks when the green sensi tivity LED turns on The audio beep increases in frequency YELLOW JACKET AccuPRoseE Il Lo Bat Sensitivity O level mdi cators Lo Norm Hi Sensitivity adjust Power ON OFF AccuProbe II Keypad Adjusting the sensitivity levels To choose another sensitivity level press the Sensitivity button The LED below each level will change indicating the new setting The leak detector will default to the NORM sensitivity level automatically once the unit comes out of the warm up cycle and the green LED turns on Using the Leak Standard Use the leak standard to determine that the leak detector performs to specifications 1 Lift off the plastic sealing cap on the top of the LEAK STANDARD 2 POWER ON the unit After WARM UP and when READY expose the sensor directly to the small hole in the top of the bottle ca
9. nd remove door Install 4 AA alkaline batteries observing the proper battery polarity as labeled AccuProbe II 1 Loosen screw located at rear end of unit and pull down hinged battery door to open as shown 2 Always insert all four batteries with the proper polarity 3 Alarm speaker aN Low battery indicator Sensitivity level indicators AccuProbe Il inside the battery compartment and shown above Reinstall the battery door and tighten the screw I Operating Instructions AccuProbe UV 1 POWER ON The detector is turned ON and OFF by pressing the POWER button see figure 1 below 2 WARM UP The detector automatically starts heating the sensor to condition it for use While in this WARM UP phase and until ready the instrument will signal audibly by beeping slowly and visually by flashing the sensitivity LEDs and the zero 0 in the SmartAlarm display window Warm up time is usually about 20 SECONDS or less 3 SEARCH The detector is ready for leak searching when the sensitivity LEDs stop flashing and the beep rate increases At this time the zero in the display window stops flashing When a leak is detected the beeping sound and flashing LED in the probe will increase in frequency and the SmartAlarm digital LED display will turn on indicating the leak size If no leak is detected go to HI sensi tivity and continue
10. p The beep rate should increase to an alarm For the AccuProbe the SmartAlarm should display a number greater than 2 If the SmartAlarm fails to display 2 or above leave the detector on for approximately 15 to 30 seconds longer and retest This indicates that the sensor and electronic circuit are functioning properly 3 Replace plastic cap seal after leak test Note Replace the leak standard when the green color is no longer visible Removable sealing cap d Non removable cap with leak opening Non ozone depleting chemical has green color Leak Standard Bottle Low battery indication Maintenance Replace the batteries when the red low battery Batteries Replace the batteries when the LED comes on see page 3 Follow instruc red low battery LED turns on See BATTERY tions under section titled BATTERY IN INSTALLATION on page 3 STALLATION on page 3 Audio alarm mute AccuProbe UV Sensor filter replacement Unscrew the sensor tip as shown to replace the filter For optimum performance replace filter whenever it becomes visibly dirty with grease or oil or every 2 3 months depending on use To silence the audio alarm press the MUTE button Press a the MUTE button again to K lt restore the audio alarm Sensor failure mode Note Never clean dirty filters with a solvent or soap and water Always replace with a new filter supplied with the leak detector or they can be re ordered from your supplier
11. searching SmartAlarm Display The SmartAlarm LED Display is a digital leak size indicator that numerically displays the leak size on a scale of 1 to 9 for all HFC and HCFC refrigerants regardless of the sensitivity setting This value helps you decide whether or not the leak is large enough to require repair For example when in the HI sensitivity mode the detector may sound a full audio alarm but the Smar tAlarm Display may show a low number indicat ing that the leak is very small In contrast when in the LO sensitivity mode a full audio alarm may not sound but the SmartAlarm may show a high num ber indicating that the leak is large YELLOW JACKET Low battery indicator a Sensitivity UV LED n indicators Power ON OFF B Sensitivity Audio 7 aoust j prema mute Power ON OFF 4 Figure 1 SmartAlarm DISPLAY LEAK SIZE DISPLAY OZ YR lt 0 1 2 82 1 TO 3 4TO6 0 1 to 0 5 2 8 14g 7TO9 gt 0 5 14 1g HFC and HCFC Refrigerants The maximum value displayed once the source of the leak is located indicates the leak size This value helps you decide whether or not a leak is large enough to require repair The table above shows the leak rates corresponding to the SmartAlarm numeri cal display UV LIGHT OPERATION N CAUTION EMITS ULTRAVIOLET RADIATION e This UV LED during operation radiates UV light e Avoid direct eye and skin exposure to UV light e If viewing the UV