User`s Manual - IngMar Medical
Contents
1. disengaged gt C 50 15 Both outer springs engaged gt C 20 6 All 3 springs engaged gt C 10 3 mlL cmH20 Calibration Calibrated QuickLung information is shown in Technical Data below Please contact IngMar Medical for information on purchasing a calibrated version of the QuickLung IngMar Medical recommends annual re calibration Maintenance This device is maintenance free Please contact IngMar Medical for information on replacement parts Technical Data Compliance Note Static compliance is measured as the change in unit Volume per change in unit Pressure in steady state isothermal condition of a ventilation cycle including compliance resulting from gas compressibility QuickLung Jr in parenthesis C50 C15 0 5 0 15 L kPa 10 at 500 200 mL tidal volume C20 C6 0 2 0 06 L kPa 10 at 500 200 mL tidal volume C10 C3 0 1 0 03 L kPa 10 at 300 100 mL tidal volume Resistance Note Parabolic orifice resistor pressure drops selected from ASTM F1100 K values for inspiratory flows at 2 1 and 0 5 L s respectively Rp5 K 2 70 20 equivalent orifice size 8 48mm pressure drop 10 80 cmH20O at 2 L s Rp20 K 17 61 20 equivalent orifice size 5 31mm pressure drop 17 61 cmH20O at 1 L s Rp50 K 108 70 20 equivalent orifice size 3 37mm pressure drop 27 20 cmH20 at 0 5 L s pursuant definitions of ASTM F1100 and IEC 60601 2 12 Weight 3 Ibs 8 oz 1 6 kg Dimension
2. Legal Information Product Warranty Products manufactured or distributed by IngMar Medical Ltd are fully warranted covering materials and workmanship for a period of one year from the date of shipment except for products with stated warranties other than one year IngMar Medical reserves the right to perform warranty service s at its factory at an authorized repair station or at the customer s installation IngMar Medical s obligations under this warranty are limited to repairs or at IngMar Medical s option replacement of any defective parts of our equipment except fuses and batteries without charge if said defects occur during normal service Claims for damages during shipment must be filed promptly with the transportation company All correspondence concerning the equipment must specify both the model name and number and the serial number as it appears on the equipment Improper use mishandling tampering with or operation of the equipment without following specific operating instructions will void this warranty and release IngMar Medical from any further warranty obligations The above is the sole warranty provided by IngMar Medical Ltd No other warranty expressed or implied is intended Representatives of IngMar Medical are not authorized to modify the terms of this warranty For factory repair service call Toll free 1 800 583 9910 International 412 441 8228 Facsimile 412 441 8404 Limitation of Liability IngMar Med
3. ical Ltd s liability whether arising out of or related to manufacture and sale of the goods their installation demonstration sales representation use performance or otherwise including any liability based upon above defined product warranty is subject to and limited to the exclusive terms and conditions as set forth whether based upon breach of warranty or any other cause of action whatsoever regardless of any fault attributable to IngMar Medical and regardless of the form of action including without limitation breach of warranty negligence strict liability or otherwise THE STATED EXPRESSED WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY FITNESS FOR ANY PARTICULAR PURPOSE OR NONINFRINGEMENT IngMar Medical Ltd shall not be liable for nor shall buyer be entitled to recover any special incidental or consequential damages or for any liability incurred by buyer to any third party in any way arising out of or relating to the goods Intended Use The QuickLung test lung may be used for ventilator performance verification The user has to bear in mind however that the design of modern ventilators is complex and these devices incorporate a great variety of features and performance parameters The purpose of the lung simulator within the context of ventilator performance verification is solely to assist in implementing test procedures mandated o
4. r recommended by the ventilator manufacturer Principle of Operation QuickLung is a precision lung simulator that operates with a combination of springs and orifices to represent a number of different settings for the respiratory parameters Resistance and Compliance The maximum volume is limited by a mechanical limit to the opening angle of the bellow panels Resistances are parabolic by virtue of their design as simple orifices Compliance is linear since extension springs and a torsion bar are used to create recoil forces Optionally leaks are created by an orifice venting to atmosphere and controlled through a stopcock Operation Always ensure that the elbow connector is fully inserted into the connector port on top of the QuickLung You will feel a snap action when it is properly engaged To remove the elbow pull straight out vertically while holding down the QuickLung with your other hand To change the setting of Resistance either turn the elbow connector so that its R 50 gg V pe black triangle is aligned with the arrows on the QuickLung panel v or a turn the leak adapter connector so that the stopcock attachment is aligned with the respective arrows on the QuickLung panel It is the responsibility of the user to use only 90 positions in between positions will yield undefined results The following spring combinations result in the recommended Compliance settings QuickLung Jr in parenthesis All springs
5. s 11 x 7 3 x 2 inches 280 x 185 x 52 mm Contact Information www ingmarmed com info ingmarmed com voice 412 441 8228 toll free 800 583 9910 fax 412 441 8404 L APA 6 0 OL SI INGMAR MEDICAL www ingmarmed com QuickLung Precision Test Lung For calibrated and non calibrated versions of QuickLung and QuickLung Jr User s Quick Reference
Download Pdf Manuals
Related Search
Related Contents
AT03 User Manual - wireless charging led flashlight,a torch,scuba Motor System for Satellite Receiver Digitus AL-9E2000-01I fiber optic cable LE LOMBOSTAT OBD link connector and tester user manual Fuente de alimentación estabilizada 13505.93 Sony A3802LENSBDL How to Use Copyright © All rights reserved.