Home
VERSION: V 3.0
Contents
1. The projector must be installed in a location with adequate ventilation at least 50cm 20inches from adjacent surfaces Be sure that no ventilation slots are blocked USER MANUAL LASER SAFETY WARNINGS SAFETY WARNINGS Y Potential laser injury hazard exists with this product Read these Instructions carefully which include important information about installation safe use and service AN Caution Avoid direct eye contact with laser J light Never intentionally expose your eyes or others to direct laser radiation AN Caution This laser product can potentially cause instant eye injury or blindness if laser light directly strikes the eyes AN Caution t is illegal and dangerous to shine this laser into audience areas where the audience or other personnel could get direct laser beams or bright reflections into their eyes AN Caution Itis a US Federal offense to shine any laser at aircraft A N Caution There are no user serviceable parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact the dealer nearest to you AN Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure NON INTERLOCKED HOUSING WARNING This unit contains high power laser devices internally Do not open the laser housing due to potential exposure to unsafe levels of laser r
2. LSX 300SRGB LASER EFFECT UNIT VERSION V 3 0 This manual contains important laser system safety and operation information Read and understand all instructions prior to powering on laser unit the first time to avoid laser eye injury and to avoid breaking the law Keep this manual in a safe place for future reference USER MANUAL WARNING DATA DATA Lasers can be hazardous and have unique safety considerations Permanent eye injury and blindness is possible if lasers are used incorrectly Pay close attention to each safety REMARK and WARNING statement in the user manual Read all instructions carefully BEFORE operating this device A Attention a Important A N Caution A Laser A Recycle A fx Indoor Wastebin r Location Indicates a skill or other useful information for special situation Indicates important information to protect people from laser incident or damage Prevent damage or injury from incorrect operation Laser safety warming labels To protect the environment recycle packing material wherever possible The projector is for indoor use only IP20 Use only in dry locations Keep this device away from rain and moisture excessive heat humidity and dust Do not allow contact with water or any other fluids or metallic objects Don t throw this product away just as general trash please dispose of this product following the abandon electronic product regulation in your country
3. DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system e The DXM output and input connectors are pass through to maintain the DMX circuit when power is disconnected to the unit e Each fixture needs to have a DMX address to receive the data from the controller The DMX address number which could be read from rear panel of each fixture is between 000 511 e The end of the DMX 512 chain should be terminated to reduce signal errors Proper Laser Set Up amp Usage This fixture has been designed to be hung It is recommended for safety purposes your lighting effect are properly mounted using a suitable hanging clamp and 10 USER MANUAL safety cable Items appropriate for safe and effective mounting are easily sourced from your lighting vendor International laser safety regulations require that lasers must be operated in the fashion illustrated below with a minimum of 3 meters 9 8 ft of vertical separation between the floor and the lowest laser light vertically Additionally 2 5 meters of horizontal separation is required between laser light and audience or other public spaces 3 Meters CAUTION Use of controkb adjustments or performance of procedures other than what is specified herein may result in hazardous radiation exposure Rigging the Fixture CAUTION Please consider the respective national norms durin
4. mounting plugs rear view 1 Shield 2 Signal 3 Signal A Caution At the laser fixture the DMX cable has to terminate with a terminator Solder a 120 Ohm resistor between Signal and Signal into a 3 pin XLR plug and plug and plug it in the DMX output of the last fixture PIN 3 BIN 2 USER MANUAL Building a serial DMX chain nl nn I uy shy i a DMX 512 t L a Co o o _ 12002 il Controller operation ye JE ii a T TAT i Mastenslave t i AL saaneena SS te operation e If you are using the standard DMxX controllers you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMxX chain If you wish to connect DMxX controllers with other XLR outputs you need to use adapter cables e Connect the DMX output of the first fixture in the DMX chain with the DMxX input of the next fixture Always connect output with the input of the next fixture until all fixtures are connected e If you use a controller with 5 pins DMX connector you need to use a 5 to 3 pins adopter e At last fixture the DMX cable has to be terminated with a terminator Solder a 120 Ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pins XLR plug and plug it in the DMX output of the last fixture e Connect the fixture together in a daisy chain by XLR plug cable from the Output of the fixture to the input of the next fixture The cable cannot be branched or split to a Y cable
5. the user to follow the safety instructions and warning notes written in this manual e The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the device USER MANUAL Front Panel no nae FUNCTION a Laser output Laser output aperture B POWER Main power indicated LED Red is ON MUSIC IR Synchronize to detected music signal IR indicator flashing for each signal received af Infrared Remote Receiver HANGING with 2 knobs on both sides to fasten the unit and BRACKET a mounting hole to fix a mounting hook 5 Cooling fan Cooling and never cover this fan outlet USER MANUAL Rear Panel E E E E a o T wet AA C a r omn Swich ovand of ipower a enema van soest ana rregi taeae o keyswnen Make sure te professional person use P10 meros For emergency serso Ci LED contro Panet wialioent LED contro paner or tne system 2 sateyeye Atachtiesney cade is omino 3P male XUR pon usna oron 1a pmxouput 3P Female XLR por using or Dux CONTROL amp FUNCTION e Regular breaks during operation are essential to maximize the life of this device as it is not designed for continual use e Do not switch the unit on and off in short time intervals e Always unplug the unit when it is not used for a longer time Or before replacing the bulb or start servicing e Inthe event of serious operation problems stop using the
6. the mains with particular caution Make sure that the available voltage is not higher than stated on the rear panel Always plug in the power plug least Make sure that the power switch is set to off position before you connect the device to the mains The power plug has to be accessed after installing the device Make sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time Always disconnect from the mains when the devise is not in use or before USER MANUAL cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord e tis essential to connect the yellow green conductor to earth e The electric connection repairs and servicing must be carried out by a qualified employee e Do not switch the fixture on and off in short intervals as this would reduce the laser diode life e For replacement please use fuses of same type and rating only e f the device has been exposed to drastic temperature fluctuation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature e Do not shake the device Avoid brute force when installing or operating the device e When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your
7. CT The label indicates the laser beam output aperture LASER EMISSION DATA Laser Classification Class 3B Cooling TEC amp Fan Cooling As measured under IEC measurement conditions for classification Note The laser diode is exposed to extreme conditions due to the high output power and therefore only has a limited life Like all wear parts the laser diode is not subject to any guarantee claims 5 USER MANUAL LASER COMPLIANCE STATEMENT This laser product complies with EN IEC 60825 1 Ed 2 2007 03 GENERAL SAFETY INSTRUCTIONS Every person involved with installation and maintenance of this device has to Be qualified Follow the instructions of this manual CAUTION Be careful with your operations With a high voltage you can suffer a dangerous electric shock when touching the wires This device has left out premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Y Important The manufacturer will not accept liability for any resulting damage caused by the non observance of this manual or any unauthorized modification to the device Please consider that damages caused by manual modifications to the devise are not subject to warranty Never let the power cord come into contact with other cables Handle the power cord and all connections with
8. adiation The laser power levels accessible if the unit is opened can cause instant blindness skin burns and fires USER MANUAL LASER SAFETY AND OPERATING INSTRUCTIONS a STOP AND READ ALL LASER SAFETY DATA Laser light is different from any other light source witch you may be familiar The light from this product can potentially cause eyes injury if not set up and used properly Laser light is thousands of times more concentrated than light from any other kind of light source This concentration of light power can cause instant eye injuries primarily by burning the retina the light sensitive portion at the back of the eye Even if you can not feel heat from a laser beam it can still potentially injure or blind you or your audience Even very small amounts of laser light are potentially hazardous even at long distances Laser eye injuries can happen quicker than you can blink It is incorrect to think that because these laser entertainment products split the laser into hundreds of beams or laser beam is scanned out in high speed that an individual laser beam is safe for eye exposure This laser product uses dozens of milliwatts of laser power Class 3B levels internally Many of the individual beams are potentially hazardous to the eyes lt is also incorrect to assume that because the laser light is moving it is safe This is not true Nor do the laser beams always move Since eye injuries can occur instantly it is c
9. ction Optional EFFECT PAUSE CHANGING PATTERN SOUND SENSITIVITY FIAED PATTERN FROM 1 TO 48 PATTERN REPEATING USER MANUAL ergs In REM mode to turn ON OFF laser In any ON OFF standalone mode excepted SLA mode pressing 2 seconds for activate REM mode H AUTO AUTO running show MUSIC SOUND activated show The blue music LED indicator is flashing when sound signal is detected Sound Sensitivity In Sound Activated Show press MUSIC B an 1 9 to do sensitivity setting 9 is the most 0 0 0 0 _ sensitive COLOR Cycle through Programmed Color Color 3 amp Color CHANGING 2 Color 1 TR PATTERN Ney To show and change patterns CHANGING O FIXED Choose favorite PATTERN from 1 to 48 PATTERN PATTERN Last PATTERN and current PATTERN cycle REPEAT repeating y Attention Any control or setting in remote will be saved in ram until A the system is rebooted The system is in AUTO show in any first remote mode after reboot DMX Channels Chart CHANNEL VALUE FUNCTION 000 049 Laser OFF D 050 099 AUF 100 149 AUS 150 199 250 255 DMX MODE USER MANUAL 000 051 1 Group Patterns 052 103 2 Group Patterns CH 2 104 055 3 Group Patterns GROUP 156 207 4 Group Patterns 208 255 5 Group Patterns ee corer Light Blue Color Rolling d j _ 000 Full pattern without clipping CH5 CLIPING 001 127 0 99 fixed patter
10. e DMX Connections DMX Channels Measurement N Weight AC100 240V 50 60Hz 250V 1A Slow Blow 20mm Glass 15W 20 Audio Sound Activated 150mW 650nm red 50mW 532nm green 80mW 450nm blue Class 3B EN60825 1 2007 10 40 C 3 pins XLR Male Female Max 17 channels See picture below 1 5Kg 190mm _ Every information is subject to change without prior notice The availability of particular products may vary by region Please check with the dealer A 4a MONACOR MONACOR INTERNATIONAL GmbH amp Co KG Zum Falsch 36 28307 Bremen Germany INTERNATIONAL Copyright by MONACOR INTERNATIONAL All rights reserved 22
11. e laser appears to be emitting only one or two beams e Do not use laser if housing is damaged or open or if optics appear damaged in any way e Never open the laser housing The high laser power levels inside of the protective housing can start fires burn skin and will cause instant eye injury e Never leave this device running unattended e The operation of a Class 3B laser show laser is only allowed if the show is controlled by a skilled and well trained operator familiar with the data included in this manual e The legal requirements for using laser entertainment products vary from country to country The user is responsible for the legal requirements at the location country of use e Always use appropriate lighting safety cables when hanging lights and effects overhead LASER EXPOSURE WARNING LASER LIGHT A AROVID DIRECT EYE EXPOSURE Further guidelines and safety programs for safe use of lasers can be found in the ANSI Z136 1 Standard For Safe Use of Lasers available from www laserinstitute org Many local governments corporations agencies military and others require all lasers to be used under the guidelines of ANSI Z136 1 Laser Display guidance can be obtained via the International Laser Display Association www laserist org USER MANUAL LASER SAFETY LABEL REPRODUCTIONS Caution Class 3B LASER RADIATION WHEN OPEN AVOID EXPOSURE TO BEAM LASER RADIOATION AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODU
12. fixture and contact your dealer immediately USER MANUAL Operating Mode Attention Once after every power on laser the VERSION and MANUFACTURE INFORMATION will be shown in LCD monitor of rear panel When laser is powered on LCD monitor on rear panel shows the current operating standalone mode or DMX address of DMX mode With help of LCD control panel is very easy to set and change the operating mode of laser After every resetting and saved the new mode information will be shown on LCD monitor at next power on FUNC Mode Option to choose the operating mode of laser ENTER Confirmation to confirm the laser to show the present mode at the next operation UP DOWN to change operating mode parameter or DMX address DOWN BIG gt OPERATION SCAN S 50G RE SCAN S 100G RE SCAN S 400B RE FUNC L F AuP 5 6 gt mS 5 AEE BH o u L 7 SoP IS 0 ENTER ENTER ENTER Eg ae Lo cJ i ico on F ENTER ENTER wn wn Oo O C ENTER SOS SOUND ACTIVATED SHWO fast AUP Auto running pattern effect show SOP Sound activated pattern effect show USER MANUAL rrr Attention In preprogrammed standalone MUSIC SHOW mode the A laser beam will be blank out in 3 seconds without AUDIO MIC activated signal DMX MODE e Press FUNC to enter MODE selection e Till to LED panel shows 001 e Press ENTER to confirm setting n The laser is working in DMX MODE Wit
13. g the installation The installation must only be carried out by an authorized employee or dealers e The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation e The installation must always be secured with a secondary safety attachment e g an appropriate catch net This secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main attachment fails USER MANUAL e Make sure the area below the installation place is free from unwanted persons during rigging de rigging and servicing e The operator has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another time e The operator has to make sure that safety relating and machine technical installations are approved by a skilled person once a year e The fixture should be installed in the position where persons cannot reach and where persons may walk by or be seated CAUTION When installing the device make sure there is no highly in inflammable material decoration articles etc in between a distance of min 0 5 meter PRODUCT OVERVIEW e This device has left out premise in absolutely perfect condition In order to maintain this condition and to ensure safe operation it is necessary for
14. h help of UP and DOWN button the DMX FUNC UP DOWN ENTER address could be set I 4 Attention In DMX MODE once the DMX cable is connected with laser and DMX controller the DMX LED in front panel of laser will be ON SLAVE MODE e Press FUNC to enter MODE selection e Till to LED panel shows SLA e Press ENTER to confirm setting The laser is working in SLAVE MODE Connect MASTER laser with several SLAVE laser with DMX cable SLAVE lasers are doing exactly the same laser show as MASTER laser Please check chapter for DMX cable connection for reference REM MODE Remote Optional e Press FUNC to enter MODE selection e Till to LED panel shows REM e Press ENTER to confirm setting Please check Remote Instruction for remote control details A Attention In any standalone mode excepted REM and SLA press ON OFF for 2 second to activate remote function USER MANUAL PATTERN MIRROR REVERSE SETTING e Press FUNC to enter MODE selection e Till to below LED display is y shown in LED panel and the x laser will show pattern right m side it e e Press ENTER to confirm the om See ee setting e With help of UP button the IS 4 Y i X laser scanned world in x DMX 512 direction could be reversed 0 ra as the graphic as below FUNC UP DOWN ENTER e With help of DOWN button the laser scanned world in y GE direction could be reversed aie ra as the graphic as below e i FUNC UP DOWN ENTER Remote Instru
15. ight case contain following items a ty Laser Light 1 PCS KEYs for key switch 2PCS Interlock Connector Power Cord USER MANUAL Power Supply To determine the power requirements for a particular fixture see the label affixed to the back plate of the fixture of refer to the fixture s specifications chart A fixture s listed current rating is its average current draw under normal conditions All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture check that the source voltage matches the fixture s requirement USER MANUAL The unit is supplied with a power plug appropriate to its voltage and destination Should any other connections be required they must be carried out with the following configuration FUSE 5mmx20mm FUSE F 1 A 250V L CableEU CabietUs Light blue White Neutral N Yellow Green Green Earth DMX 512 connection between fixtures The fixture is equipped with 2 pin XLR sockets for DMX input and output The sockets are wired in parallel Only use a shielded twisted pair cable designed for 3 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another Occupation of the XLR connection DMX output DMX input XLR mounting sockets rear view XLR
16. n clipped 128 255 Clipping Speed poo USER MANUAL 100 5 fixed pattern zoomed ZOOMING 000 255 F 7 M ast to Slow CH 8 0004127 127 0 359 0 359 degree fixed Y axis rolled fixed 0 359 degree fixed Y axis rolled axis rolled Y AXIS 128 191 Clockwise rolling ROLLING 192 255 Anticlockwise rolling i 0 255 OOO O ROLL Fast to Slow CH 10 000 127 0 359 degree fixed X axis rolled X AXIS a 191 Clockwise ma O ROLLING 1 192 255 255 Anticlockwise Anticlockwise rolling si CH 11 ROLL 0 255 Fast to Slow CH 12 000 127 0 359 degree fixed Z axis rolled Z AXIS 128 191 Clockwise rolling ROLLING 192 255 Anticlockwise rolling CH 13 jae ROLL Fast to Slow CH 14 000127 127 128 different fixed 128 different fixed position on X axis on 128 different fixed position on X axis axis X AXIS E J 191 Clockwise aaa I MOVING 192 255 255 Anticlockwise moving si moving CH 15 0 255 Fast to Slow CH 16 000 127 128 different fixed position on Y axis X AXIS 128 191 Clockwise moving MOVING 192 255 Anticlockwise moving CH 17 0 255 Fast to Slow MOVE 20 USER MANUAL PATTERN LIST 000 015 032 047 048 063 064 079 080 095 112 127 160 175 176 191 192 207 a Ge music PRATY 224 239 21 USER MANUAL SPECIFICTAIONS Mains Input Fuse Total Power X Y Axis Beam Angle Music Control Laser Power Laser Classification Laser Safety Standard Condition Temperatur
17. own and the safety of others e The minimum distance between the fixture and surrounding walls must be more than 50cm e Always fix the fixture with an appropriate safety rope Fix the safety rope at the safety rope only e The ambient temperature must be between 10 C to 40 C e Please use the original packaging if the device is to be transported e Please consider that unauthorized modifications on the device are forbidden due to safety reasons CAUTION Operate the device only after having familiarized with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation CAUTION If this device will be operated in any way different to the one described in this manual the product may suffer damages and the warranty word USER MANUAL BEFORE OPERATION OPERATION Unpacking Instructions A N CAUTION Immediately upon receiving a fixture carefully unpack the carton check the contents to ensure that all parts are present and have been received in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear damage from shipping or the package itself shows signs of mishandling Save the package and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing What is included The carton or fl
18. ritical to prevent the possibility of any direct eye exposure In the laser safety regulation it is not legal to aim Class 3B lasers in areas which people can get exposed This is true even if it is aimed below people s faces such as on a dance floor e Do not operate laser without first reading and understanding all safety and technical data in this manual e Always set up and install all laser effects so that all lasers light is at least 3 meters 9 8 feet above the floor on which people can stand See Proper Laser Set up amp Usage section later in this manual e After set up and prior to public use test laser to ensure proper function Do not 3 USER MANUAL use if any defect is detected Do not use if laser emits only one or two laser beams rather than dozens hundreds as this could indicate damage to the diffraction grating optic and could allow emission of higher laser levels e Do not point lasers at people or animals e Never look into the laser aperture or laser beams e Do not point lasers in areas in which people can potentially get exposed such as uncontrolled balconies etc e Do not point lasers at highly reflective surfaces such as windows mirrors and shiny metal Even laser reflections can be hazardous e Never point a laser at aircraft this is a federal offense e Never point un terminated laser beams into the sky e Do not expose the output optic aperture to cleaning chemicals e Do not use laser if th