Home

ND1 - First start

image

Contents

1. Do not supply the analyser from networks near the devices generating pulse noises in the supply network and do not use common grounding circuits with them All shields should be earthed unilaterally near the analyser Avoid a common earth conductor with other devices Apply the general principle that wires group of wires leading different signals should be LED in the longest possible distance between them and crossing of such groups should be made at right angle A switch or a circuit breaker should be installed in the building installation and located near the analyser easy accessible by the operator and suitably marked It is not allowed to disassemble the analyser Protections ensuring the device safety can be less effective in case of exploitation inconsistent with manufacturer s indications and principles of a good engineering practice Preparing the Device to Work 1 4 Unpacking A Take the ND1 analyser out from the shipping packing The data plate with the version code factory serial number and supply parameters are placed on the analyser casing Check the conformity of the analyser version with your order B Take accessories out from the shipping packing SanDisk Ultra CompactFlash 75 ve Samisk 1 Users manual First Start 1 pc 2 CompactFlash memory card 1 pc F Fixing brackets 4 pcs 4 Keys 2 pcs 5 USB cable of 1 8 m long shielded 1 pc
2. G A w General Inputs Alarrns Analog settings outputs oy E Si Power Visualization Archivization Ethernet quality s E Xx 6 Modbus File browser Security System information General information 1 1 Introduction The aim of this document is to help in the quick preparation to work of the ND1 Analyser of 3 phase Power Network Parameters so called first start lt is an integral part of the whole documentation delivered with the device The complete user s manual has been placed on the CD enclosed to the delivered device and constitutes fundamental information about the product and its usage and possible applications The complete users manual is also available on the manufacturer s web page at http www lumel com pl 1 2 Device Application The ND1 analyser is applied for the measurement and analysis of 3 phase 3 or 4 wire power networks parameters in balanced or unbalanced systems 1 3 Selected Remarks Related to the Device Installation Note You must acquaint with the full list of remarks related to safety principles included in the user s manual in the chapter 3 3 Analyser Work Conditions In its scope it is recommended to observe following recommendations All operations concerning mounting and preparing electrical connections must be carried out by personnel with suitable entitlement Moreover national regulations for the prevention of accidents must be observed
3. Jo s U 1 24 33 4 Sa U 6 U Ta 8 a 9a 10 1 Hey U 12 o Fig 1 3 Three wire network Indirect measurement with the use of 2 current transformers and 2 or 3 voltage transformers 10 Fig 1 4 Four wire network Indirect measurement with the use of 3 current transformers and 2 or 3 voltage transformers RS485 1 Fig 1 5 Three wire network Semi indirect measurement 11 RS485 1 wire network Direct measurement Fig 1 6 Three a o tT r o o q Se lol e cs e e e e e elo a RS485 1 A I Y4 PYTA NP iY 4 gt 4 A gt l A gt l A gt 4 L 11 L774 L eqj4 L N N m st wo co o 2 a L1 L2 L3 Fig 1 7 Four wire network Direct measurement 12 Fig 1 8 Four wire network Semi indirect measurement Fig 1 9 Four wire network Indirect measurement with the use of 4 current transformers 13 First Start and Basic Analyser Configuration 1 After turning on the power supply the manufacturer s logo with the start screen appears The logo is displayed during the time necessary for the initialization of analyser processes Next the data visualization screen appears a 2302 230 2 230 2 u 230 2 LUMEL 2 Please touch any place on the screen to bring the
4. 1 2 3 4 5 6 7 8 9 AL4 6 AO3 AO4 E RS485 2 Ethernet RS485 and Ethernet interfaces Symbol of terminal Terminal description group Connection sockets of the measuring package L1 L2 L3 N acc to the order and version code Connection sockets Alarms AL 1 6 6 relays NC or NO Binary input BI 1 12 12 inputs Analog outputs AO 1 4 4 outputs L N PE Connection sockets of the supply voltage Sz 85 230 253 V a c d c 24 V d c 30 mA Object feeders destined to supply external systems RS485 1 RS485 2 Communication interfaces RS485 Master RS485 Slave Ethernet Ethernet 10 Base T Functional earthen terminals to connect screens 1 7 1 Mounting of the Power Supply Filter During the device installation apply the delivered power supply filter when connecting the supplying wire to the analyser To mount the power supply filter one must reeve all the three supplying wires L N PE through the filter core creating a full loop around it Fig 1 1 Fig 1 1 Connection of the power supply filter 1 7 2 Connection of Measuring Signals Note 1 To connect measuring signals use the plug in strip from ZA ND1 accessories 2 Signal connections are presented on figures in the view from the ND1 terminal plate side ND1 a io a gt ta Fig 1 2 Four wire network Indirect measurement with the use of 4 current transformers and 2 or 3 voltage transformers
5. Context Menu up Urms L1 Urms L2 El o gt E AE 3 To switch to the analyser configuration please select the following icon Go to the analyser configuration menu 14 4 The users selection window appears MARES ES 8 39 who carries the given configuration out At the first start there is only the Administrator user The logging FE follows without the password after simply accepting the window The Administrator can edit another user s name and access password to the analyser after transiting into the ND1 Control Panel 5 Next select the kind of analyser EEE ela EEE parameter configuration For now please Configuration select Edit current configuration p Open configuration from file 6 The ND1 control panel appears This is the startin oint to carry out a full Ea E e E i G MA w configuration of the ND1 analyser kaka Tl Ngee a dio settings outputs ND1 Control Panel E kl ks Sa Power Visualization Archivization Ethernet quality s E RO Modbus File browser Security System information 7 Please select the Inputs icon The configuration dialogue of available current inputs appears NDI Contre Zenel ch Inputs a Nominal TU thiwi 5 A f 230 W General Analog settings s outputs Base frequency 50 Hz A a La 3 d k oh 1 Connection type 4 wire input 3 EF Power Visualization Archivization Ethernet l quality Voltage ra
6. OF INTEGRATION SYSTEMS ACCESSORIES for MEASURING INSTRUMENTS SHUNTS CUSTOM MADE PRODUCTS ACCORDING CUSTOMER S REQUIREMENTS WE ALSO OFFER OUR SERVICES IN THE PRODUCTION OF ALUMINIUM ALLOY PRESSURE CASTINGS PRECISION ENGINEERING and THERMOPLASTICS PARTS SUBCONTRACTING of ELECTRONIC DEVICES SMT PRESSURE CASTINGS and OTHER TOOLS QUALITY PROCEDURES According to ISO 9001 and ISO 14001 International Requirements All our instruments have CE mark For more information please write to or phone our Export Department Lubuskie Zaktady Aparatow Elektrycznych LUMEL S A ul Sulechowska 1 65 022 Zielona Gora Poland EU http www lumel com pl Export department Tel 48 68 329 53 02 Fax 48 68 325 40 91 e mail export lumel com pl 2009 LZAE Lumel S A All right reserved ND1 09A 4 08 03 10
7. 6 Seal ND1 casing panel 1 pc 7 Set of plugs 1 pc 8 CD with the software and user s manual 1 pc 9 Power supply filter 1 pc Guarantee card Note Before unpacking the memory card you have to carry away electrostatic charges from the body 1 5 Installation in the Panel min 144 Put the seal from the standard accessory set on the casing see section 1 4 After fixing the analyser into the panel the seal protecis the part behind the panel against the influence of risks appearing from the panel frontal side resulting from the IP65 protection grade The ND1 analyser is fixed to the panel by means of four screwed fixing brackets from the standard accessory set see section 1 4 Basic fixing and panel cut out dimensions are presented on the above figure 1 6 Analyser Operating Conditions The analyser can work at ambient temperature 0 50 C 32 122 F and max 5 of relative humidity without condensation The device in the shipping packing can be transported and stored in the temperature 20 60 C 4 140 F 1 7 Terminal Plate Binary inputs Bl1 12 Alarm outputs AL1 6 ND1 measuring Analog outputs AO1 4 package HE gt g ND1 supply o 2 m e m Ba Object supply feeders AL1 3 AO2 EL EH EEIELEEEEET E
8. ANALYSER OF 3 PHASE POWER NETWORK PARAMETERS ND1 TYPE BIE FE SEE Urrms L1 Urrns 230 2 EM oo 24 230 2 4 230 2 230 2 E 230 2 First Start Ce LZAE Lumel S A Sulechowska 1 65 022 Zielona G ra Poland UE Caution Before approaching to fit and activate the device you must become absolutely familiar with safety requirements see section 1 3 Quick Start ND1 analyser Accessory set Prepare the supply wire using the delivered plug and the power supply filter do not connect to the supply Prepare the connection of measuring signals using the plug strip delivered with the ND1 accessory set ND1 2 80 an oO U A wD 4 p lt Pp P lt gt P lt gt D lt AILYAKIYAIYAIY N L3 r L2 Lim Hi KE L2 L2 Ls N E 4 Install and fix the analyser in the panel by means of delivered brackets and the seal 138 JI i z OSA DRZE BM NGN i E f v 16 155 E em O Connect the power supply O Carry the first configuration on M Ums L1 umsiz E ENA gui z 230 2 Li Jum o i si 1 230 2 230 2 02 230 24 z 230 2 28 08 09 12 38 56 ND1 Control Panel
9. configuration in ND1 data are presented in the graphic form chosen by a user You can carry out the selection of the screen type and parameters from the given or programmed data sets They may be changed from the Context menu and the Information bar of the currently displayed screen The operation of buttons is as follows The button of the group selection and parameter set in the Context menu display tables with available options After marking the element and acceptation the screen switches to the chosen settings Selection from the information bar switches cyclically between available views screen types or parameter seis 17 Selection of the screen type Selection of the parameter set 28 08 09 12 38 56 Example of screen selection Select the screen type Select the parameter set to display on the screen O Urms L1 Urms L2 Urns L Uawg O Irms L1 Irms L2 Irms L3 Iavg O PLI PLZ PL3 EP Uef Li Uc L2 Ucf L3 CO vector diagram O IcF Li Icf L2 Icf LS F LE A 420 0 AKT SZ A DOC L3 1 Urms 380 0 18 CONTROL MEASUREMENT RECORDING LUMEL SALES PROGRAM DIGITAL and BARGRAPH PANEL METERS MEASURING TRANSDUCERS ANALOG PANEL METERS DIN INSTRUMENTS DIGITAL CLAMP ON METERS INDUSTRIAL PROCESS and POWER CONTROLLERS CHART and PAPERLESS RECORDERS 1 PHASE and 3 PHASE WATT HOUR METERS LARGE SIZE DISPLAY PANELS ELEMENTS
10. tio 1 0 ID Ss oe Current ratio 1 0 E Modbus File browser Security System information 15 8 Now you can set the suitable configuration in the compliance with the type of carried out connection in the Connection type option On the same dialogue tab you may also set the voltage and current ratios Select one option serze Setting acceptation Select one option O 3 wire input 4 wire input 3 ground General Nominal IfU thw Base frequency Connection type ESP NA voltage ra p 0 Current ratis 9 The dialogue closure follows through the acceptation push button 16 10 In order to save and set the new configuration you must firstly press the closure button of the ND1 Control Panel and next select the Save and set configuration option J Confiourstion ee ree q l ko Save and set configuration D Ta On General Inputs Alarms Analog settings outputs Export to file l WL 4 y KAI k cn Configuration file name Power Visualization Archivization Ethernet Config_20090629_123516 quality s E RO Modbus File browser Security System information 11 The analyser transits into the measuring mode and you can directly observe results on the device screen according to your configuration Urms L1 Urns L2 E a 14 34 55 a un gt 0 gt 4 230 2 2 Basic operating in the measurement mode After programming settings and saving a new