Home

POWERWARE® EXPANSION CHASSIS

image

Contents

1. POWERWARE EXPANSION CHASSIS User s Guide www powerware com Powerware is a registered trademark and X Slot is a trademark of Powerware Corporation Modbus is a registered trademark of Modicon Copyright 2002 Powerware Corporation Raleigh NC USA All rights reserved No part of this document may be reproduced in any way without the express written approval of Powerware Corporation CHAPTER 1 INSTALLATION The Powerware Expansion Chassis is a connectivity device that contains a Modbus Card and two slots for other X Slot connectivity devices providing greater power management control and flexible monitoring Refer to the respective user s guide for operation of the X Slot cards to be used in the chassis Inspecting the Equipment If any equipment has been damaged during shipment keep the shipping cartons and packing materials for the carrier or place of purchase and file a claim for shipping damage If you discover damage after acceptance file a claim for concealed damage To file a claim for shipping damage or concealed damage 1 File with the carrier within 15 days of receipt of the equipment 2 Send a copy of the damage claim within 15 days to your service representative Safety Precautions Read the following precautions before you install the Expansion Chassis CAUTION e To reduce the risk of fire or electric shock install the chassis in a temperature and humidity controlled indoor environmen
2. Mount the chassis in the rack Continue to Step 4 ER eg Figure 3 Attaching the L Bracket Connect the supplied serial cable Powerware part number 124102022 to the communication port on the chassis rear panel see Figure 4 Connect the other end of the serial cable to the communication port on the UPS Input Connectors Communication Port to UPS Figure 4 Expansion Chassis Rear Panel Powerware Expansion Chassis User s Guide e 164201336 Rev A Uncontrolled Copy Installation 6 Locate the Voltage Selector switch on the bottom of the external power supply see Figure 5 Verify that the proper input voltage is selected either 115 or 230V The default is 230V O O Input e Connector Voltage Selector Switch IM gt 230V Position O O amp y DC Power Cord Je Figure 5 External Power Supply 7 Plug the DC power cord from the external power supply into one of the input connectors on the chassis rear panel 8 Plug the supplied power cord either 110V or 220V cord into the external power supply input connector Plug the other end of the power cord into a power outlet NOTE It is recommended that you plug the power supply cord into one of the outlets on the back of your UPS or an outlet powered by the UPS This allows the chassis to be protected during a power outage NOTE For UPSs with load segments it is recommen
3. and on the Bill Of Lading if applicable Use the original packaging or request packaging from the Help Desk or distributor Units damaged in shipment as a result of improper packaging are not covered under warranty A replacement or repair unit will be shipped freight prepaid for all warrantied units NOTE For critical applications immediate replacement may be available Call the Help Desk for the dealer or distributor nearest you 10 Powerware Expansion Chassis User s Guide e 164201336 Rev A Uncontrolled Copy Troubleshooting Two Year Limited Warranty US and Canada Only Powerware Corporation warrants the electronics of the Expansion Chassis to be free from defects in material and workmanship for a period of two years from Date of Purchase If in Powerware Corporation s opinion the electronics fails to meet its published specifications due to a defect in material and workmanship covered by this warranty Powerware Corporation will repair or replace the warranted Unit at no cost to the customer for parts and labor Equipment supplied by Powerware Corporation but not manufactured by Powerware Corporation is warranted solely by the manufacturer of such equipment Powerware Corporation does not warrant equipment not manufactured by Powerware Corporation This warranty does not apply to any Unit that has been subject to neglect accident abuse misuse misapplication incorrect connection or that has been subject to repair or al
4. from Powerware Corporation for your UPS Information pertaining to these services should be available in the shipping container along with this manual If not or if you would like more information call the Powerware Corporation Help Desk and ask about warranty services Powerware Expansion Chassis User s Guide e 164201336 Rev A Uncontrolled Copy 11 Troubleshooting International Limited Warranty Powerware Corporation warrants the electronics modules manufactured by Powerware Corporation Unit and batteries originally packaged in the Unit or in battery packs manufactured by Powerware Corporation against defect in material or workmanship until the earlier of 1 18 months from date of shipment or 2 12 months from date of initial start up is performed by Powerware Corporation field personnel or field personnel authorized by Powerware Corporation to carry out such service efforts on its behalf and provided that startup occurs no later that 6 months after shipment If the unit does not function in accordance with its published specification the user should give Powerware Corporation prompt notice thereof and if requested by Powerware Corporation the user shall return the warranted Unit or parts thereof to the plant or service station designated by Powerware Corporation for inspection by Powerware Corporation Any Unit which may require repair and or replacement of parts as the result of defects in workmanship or material within the stated wa
5. are Corporation shall not be liable for any delays or defaults hereunder by reason of fire floods acts of God labor troubles accidents to machinery delays of carriers or suppliers inability of suppliers to supply the impositions of priorities restrictions or other acts of government or other causes beyond its reasonable control This Warranty shall be governed by the laws of the State of North Carolina USA in all respects 12 Powerware Expansion Chassis User s Guide e 164201336 Rev A Uncontrolled Copy Class A EMC Statements FCC Part 15 NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 ofthe FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense ICES 003 This Class A Interference Causing Equipment meets all requirements of the Canadian Interference Causing Equipment Regulations ICES 003 Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouill
6. ded to plug the Expansion Chassis into the last group to be powered down This allows the chassis to be powered as long as the UPS before it shuts down completely 9 Verify that the chassis is operating normally the X1 indicators should illuminate and flicker when the chassis is communicating with your UPS see Figure 6 If the indicators are not on verify that the UPS is powered on and check the power cord and serial cable connections 10 If you installed additional X Slot cards the X2 and X3 indicators for Slot 2 and Slot 3 respectively should illuminate and flicker when the chassis is communicating with your UPS Powerware Expansion Chassis User s Guide e 164201336 Rev A Uncontrolled Copy 7 Installation 11 In some situations it may be necessary for a UPS to communicate directly to the card in Slot 3 instead of the default Slot 1 card In this case attach the UPS to the communication port on the chassis front panel and move the switch to the AUX position see Figure 6 UPS Communication Port Power Indicator NORM AUX l 1 2 Co EDO 3 O O 1 Ly3I Auxiliary Switch Figure 6 Expansion Chassis Front Panel 12 Refer to the individual X Slot card user s guide to set up the card for communication with your serial devices or network 8 Powerware Expansion Chassis User s Guide e 164201336 Rev A Uncontrolled Copy CHAPTER 2 TROUBLESHOOTING Problem Possible Cause The Power indica
7. eur du Canada EN50091 2 Some configurations are classified under EN50091 2 as Class A UPS for Unrestricted Sales Distribution For these configurations the following applies WARNING This is a Class A UPS Product In a domestic environment this product may cause radio interference in which case the user may be required to take additional measures Requesting a Declaration of Conformity Units that are labeled with a CE mark comply with the following harmonized standards and EU directives Harmonized Standards EN 50091 1 1 and EN 50091 2 IEC 950 Second Edition Amendments Al A2 A3 and A4 e EU Directives 73 23 EEC Council Directive on equipment designed for use within certain voltage limits 93 68 EEC Amending Directive 73 23 EEC 89 336 EEC Council Directive relating to electromagnetic compatibility 92 31 EEC Amending Directive 89 336 EEC relating to EMC The EC Declaration of Conformity is available upon request for products with a CE mark For copies of the EC Declaration of Conformity contact Powerware Corporation Koskelontie 13 FIN 02920 Espoo Finland Phone 358 9 452 661 Fax 358 9 452 665 68 164201336 A
8. rranty period will be replaced or repaired at Powerware Corporation s option without charge for replacement parts The cost of shipment duties or all other expenses associated with shipment of repaired or replaced items is for the account of the user Powerware Corporation will not be responsible or liable for work done or expense incurred in connection with repair or replacement except as expressly authorized by Powerware Corporation Raleigh NC USA in writing If a service engineer is required labor at current published rates and all travel and living expenses are for the account of the user Powerware Corporation does not warrant equipment not manufactured by Powerware Corporation including any battery not originally packaged with the Unit or in battery packs manufactured by Powerware Corporation The manufacturer of all such equipment shall solely warrant that equipment and Powerware Corporation shall have no responsibility or liability thereof IT IS AGREED THAT POWERWARE CORPORATION ITS PARENT COMPANY OR ANY OF THEIR AFFILIATES SHALL HAVE NO LIABILITY FOR INDIRECT INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES AND THAT THERE IS NO WARRANTY EITHER EXPRESSED OR IMPLIED BY LAW OR THE PARTIES HERETO OTHER THAN THOSE EXPRESSLY SET FORTH HEREIN THIS WARRANTY DOES NOT COVER DAMAGE TO THE UNIT CAUSED BY MISUSE ABUSE NEGLECT UNAUTHORIZED MODIFICATIONS IMPROPER MAINTENANCE ACCIDENTS OR OTHER ABNORMAL CONDITIONS Force Majeure Powerw
9. t free of conductive contaminants Ambient temperature must not exceed 40 C 104 F Do not operate near water or excessive humidity 95 max e For rack installations only The rack should be connected to a reliable earth ground in accordance with local regulations Powerware Expansion Chassis User s Guide 164201336 Rev A Uncontrolled Copy 3 Installation Installing Additional X Slot Cards O NOTE Refer to the individual X Slot card user s guide before installation There may be specific instructions that need to be completed first such as changing default jumpers Also verify that the X Slot card you are using with the chassis is compatible with the communication port on your UPS For the Powerware 9315 UPS The Powerware 9315 UPS is not compatible with the Relay Interface Adapter or the Single Port Serial Card Both cards require open collector signals AC Fail and Low Battery and the 9315 only provides RS 232 serial data through the communication port Only the RS 232 capability of the Single Port Serial Card is supported Refer to the UPS user s guide for more information The Modbus Card is factory installed in Slot 1 and must remain in Slot 1 To install additional X Slot cards 1 Remove the X Slot cover on the chassis rear panel Retain the screws see Figure 1 2 To prevent electrostatic discharge ESD place one hand on an unpainted metal surface such as the UPS rear panel Align the X Slot card with
10. teration not authorized in writing by Powerware Corporation s personnel THIS WARRANTY IS THE PURCHASER S USER S SOLE REMEDY AND IS EXPRESSLY IN LIEU OF ANY OTHER WARRANTY AND THERE ARE NO OTHER EXPRESSED OR IMPLIED GUARANTEES OR WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PURPOSE In no case will Powerware Corporation s liability under this contract exceed the value of the Unit furnished In no event shall Powerware Corporation be liable for any indirect incidental special or consequential damages Powerware Corporation shall not be responsible for failure to provide service or parts due to causes beyond Powerware Corporation s reasonable control THIS LIMITED WARRANTY IS VOID UNLESS USER RETURNS TO POWERWARE CORPORATION THE INCLUDED WARRANTY REGISTRATION CARD WITHIN THIRTY 30 DAYS OF DELIVERY Any advice furnished the Purchaser User before or after delivery in regard to use or application of Powerware Corporation equipment is furnished without charges and on the basis that it represents Powerware Corporation s best judgement under the circumstances The use of any such advice by the Purchaser User is solely and entirely at his or her own risk This limited warranty applies only to equipment installed in the fifty United States of America and Canada In other countries consult your local distributor Extended Service Coverage A full complement of warranty extensions and enhancements are available
11. the slot guides and slide the card into the slot until it is firmly seated 3 Secure the card with the screws removed in Step 1 Figure 1 Installing Additional X Slot Cards 4 Powerware Expansion Chassis User s Guide e 164201336 Rev A Uncontrolled Copy Installation Installing the Expansion Chassis The Expansion Chassis can be installed three different ways e asa freestanding device e wall mounted e rack mounted using only lU of valuable rack space To install the chassis perform the following steps 1 Freestanding Installations Only Attach the supplied adhesive feet to the bottom corners of the chassis Position the chassis close to your UPS Skip to Step 4 2 Wall Mount Installation Only Using a Phillips screwdriver remove the four screws on each side of the chassis Retain the screws Attach the supplied wall brackets to each side of the chassis using the removed screws see Figure 2 The chassis may be mounted in either orientation to the wall Attach the chassis to the wall using customer supplied screws and wall anchors Skip to Step 4 Figure 2 Attaching the Wall Bracket Powerware Expansion Chassis User s Guide e 164201336 Rev A Uncontrolled Copy 5 Installation Rack Mount Installations Only Using a Phillips screwdriver remove the four screws on each side of the chassis Retain the screws Attach the supplied L brackets to each side of the chassis using the removed screws see Figure 3
12. tor is The power cord is not not on connected Corrective Action Verify the power cord connections are secure The UPS is not powered on If the power cord is plugged into the UPS verify that the UPS is powered on Xn indicators are not If the first indicator is not on on the chassis may need to be reset Unplug the power cord from the chassis for several seconds then plug the power cord back in If the second indicator is not on the UPS is not responding Verify that the serial cable is securely attached to the chassis and to the UPS Verify that the UPS is powered on Service and Support If you have any questions or problems with the Expansion Chassis call your Local Distributor or the Help Desk at one of the following telephone numbers and ask for a Expansion Chassis technical representative In the United States Europe Middle East Africa Asia Australia 1 800 365 4892 or 1 919 870 3149 44 17 53 608 700 852 2830 3030 61 3 9706 5022 Please have the following information ready when you call the Help Desk Model number e Date of failure or problem e Symptoms of failure or problem e Customer return address and contact information Powerware Expansion Chassis User s Guide 164201336 Rev A Uncontrolled Copy Troubleshooting If repair is required you will be given a Returned Material Authorization RMA Number This number must appear on the outside of the package

Download Pdf Manuals

image

Related Search

Related Contents

アースバーセット 〔RD89〕 取扱説明書  Manuel de 1400 EH - Autowrap  設計図面 - 玉城町  Moxa VP-IR2 Series User`s Manual  Paraissait li Hsreredi et lt Samedi à la Gïau-de-Fondi  Massive Spot light 54243/53/18  Campbell Hausfeld CHN70200 Nail Gun User Manual  Wilo-Sub TWU 4…, TWU 4-…-QC, TWU 4-…-P&P  Owner`s Manual  AN2154/D: Low-Cost, 3-Phase, AC Motor Control System with  