1. 11 VOISPEED LTD VOISPEED V 6016 IP Address 192 168 0 230 MAC Address 00 00 45 60 b4 b9 Gateway 192168035 SIP Phone Number 6 2 Network Setting This section displays LAN connection settings The first table shows the actual settings whilst the second table enables the user to choose the connection Static or DHCP LAN Configuration MAC Address 00 09 45 60 b4 b9 Current Gateway 197 168 0 254 Static A new form is displayed when Static is selected Static IP IP address to assign to the adapter Subnet Mask Gateway IP address DNS Domain DNS domain Primary DNS Primary DNS IP address Alter DNS Alternative DNS IP address 6 3 SIP Setting Two similar SIP setting sections enable the user to setup both lines of the V 6016 adapter In the Basic Setting section you will need to enter the same parameters defined at the server PBX for the user connected to the relevant line UsER MANUAL VOISPEED LTD 12 Basic Setting 192 168 0 209 Account User Name lutente 1001 Regist status Registration status at the server PBX IP address of the server PBX connected to the Server Address adapter Server Por Allocated port number on the server PBX for SIP traffic default is 5060 When enabled the V 6016 adapter will regularly ENADE REJISIEN register at the PBX Reported below are the Advanced SIP settings We recommend not changing the default settings unless you are very familiar with
2. VO sptrro ANALOGUE ADAPTER VOISPEED V 6016 User Manual 2007 VOlspeed Ltd All rights reserved Total or partial reproduction of this document is prohibited without prior written consent of the publisher Such consent will only be granted in those instances when the source of the document is clearly stated Revision 1 0 Released on 22 08 2007 Declaration of conformity can been found at this internet address http www voispeed com products contormity V 6016 DDC pdf USER MANUAL O VOISPEED LTD 2 1 Index 1 A HUP CHE VASE A S 3 SECUN IDTOFIIGTIOTI icio dtd a danas lateness hu ed o Ha mda KR Ou AA od wo a cau cw id is 3 1 How to use tlie device Correctly inicia 5 5 2 Qualified Personnel iii 5 3 Se ACCOSSOLIOS iris 5 35 4 Waterproor guidellfi8S iia lies 5 3 5 Connecting other deViC S ni ng ng 5 3 0 DEVICE POSITION mee 5 3 7 Connecting to power Supply 3 5 isis 5 3 0 Cleaning th deVICO 5 2 5223890915222 0220 SX 031209 Cea ELO spe occu M Deoa nao Us Cu SR tacna 6 5 9 Product DIS POS A o e re o 6 A ds A Git 1 aiiiic42010212220662102aa2316n s2fa55466102gs2810aEi4g38853586532068 e 5 EasdsiSasEifsg 6 4 Gener l INTO dert ON 00d AA a ARAS 4 1 General specifications cm ng ng KH BH BE 8 4 2 Main TUN CUOM ANTICS m 8 4 3 List of components in the package cm ng km mm nen 9
3. Ao A a e ES Ea a SE 9 As SINS tala me p 9 AOA LEDS oa o O a O 9 5 Basic OPErallONS EE CON Pr CIO Eaa ia DS 10 Dil Mantial contguralloti ooa dioc e DI Recreo eet ioa cavis dope Cu Qu vu do eeu ode Por e oU UD 10 6 Configuration using the web interface mm mm nh nen 10 6 T Gurrent static 11 O 2 Network elu p Xm 12 0 3 SIPP SOU RN 12 6 4 Advanced settings esc coabrditoisiaitgiiaiswiilxsalikasaosglsksaslbwubnkabissusxkliViskiaisagies 14 6 4 1 SIG ITAA eer E 14 6 4 2 DSP CO TT sae iter EE 16 643 ACCOUNT CODTIO sosida iosian 6n buie zu iade sg Dude S oauiau o0 20b Runde rata 18 3 VOISPEED LTD VOISPEED V 6016 D44 Tune A Ea 18 6 5 System Mana aras 19 6 5 1 WED UID CALC Mc E 19 6 5 2 FTP Upal anian is 19 6 537 Aut Update sicrie aeiia aiea aoia ea aaee aa irapa 20 094 Clear Conti a 20 6 5 5 Backup CONIO iia 20 69 0 KRODOOE unici O 20 USER MANUAL O VOISPEED LTD 4 2 Introduction We would like to thank you for your purchase and for having chosen one our products This manual provides general guidelines for a correct use of the product In case you require further information on this product or to receive technical assistance please visit our website www voispeed com 3 Security information Please read the security rules below that you should follow when using this device Please comply with these guidelines to avoid
4. User Name 6 4 4 Time config Here you can specify a SNTP server that the adapter can use to sync its internal clock SNTP Time Set 207 46 130 100 GMT 01 00 Amsterdam Berlin Bern Rome Stockholm Vienna bal as In timeout you should specify the sync time in seconds with the SNTP server Alternatively it is possible to enter the time manually USER MANUAL VOISPEED LTD 18 6 5 System manage In this section are gathered all those functionalities useful to the administrator to configure the adapter They are devided into cathegories that are easily accessible 6 5 1 Web update Using this function it is possible to upload a configuration file that was previously saved As there are no cotrols on the file format you should take extra care in not uploading config files of other adapters Update Setting Select file Stoglia _ 2 txt2 au Update You can use this option to upload firmware updates provided by the manufacturer 6 5 2 FTP Update It is possible to use a FTP or TFTP server connected to the same network to update configuration files and firmware of the adapter You simply need to fill in the fields below and specify the operation you would like the server to perform e Application update to update the adapter s internal firmware e Config file export to export the adapter s configuration file into a text file e Config file import to upload a new config
5. and the environment 3 10 Product Warranty The Manufacturer Harpax Srl warrants its products to be free from defects in material and workmanship during the warranty period The product is covered by warranty only if it is used in compliance with the guidelines contained in this manual This warranty will be invalidated in case of manumission wrong use of the product or accidental damage This product is compliant with CE regulations The warranty period starts from the date the product has been purchased stated on the invoice and will last for twelve 12 months thereafter If a product proves to be defective UsER MANUAL VOISPEED LTD 6 in material or workmanship during the warranty period The Manufacturer will at its sole discretion repair or replace the product with a similar one new or re conditioned The replacement unit will be covered by a new warranty period that will last the remaining time on the customer s original limited warranty The old equipment substituted will automatically become property of Harpax Srl In order to have access to the warranty the user must fill out the online form that can be found on www prontopbx com or www voispeedltd com please also contact the customer support department on 01727 848186 The user must provide a valid invoice to claim warranty on the product Exclusions The warranty will be invalidated in the following cases e Damages to any parts that are meant to ware out with
6. the SIP protocol Advanced SIP Setting Register Expire Time Detect Interval Time User Agent VOlspeed adapter DTMF Mode DTMF RFC2833 L Enable PRACK Time interval in seconds between two registrations This setting is only used when Enable Register is activated Register Expire Time The adapter regularly checks whether the server is active or not This setting determines the delay between two detections User Agent Adapter s name as recognised by the server PBX DTMF Mode DTMF mode of operation during an active call RTP Initial Port Port used by the adapter to negotiate the initial Detect Interval Time 13 VOISPEED LTD VOISPEED V 6016 audio setting Enable PRACK Enables SIP signalling for message acknowledgment When enabled it signals the server to send information packets on the same port where Enable Via rport messages are received Useful when there is a NAT server between the PBX and the adapter Call Service Setting configures specific services on the line In this setting you can specify the number called when the handset is lifted By entering the Line Busy number a line free dial tone will be heard by lifting the handset No Disturb Incoming calls are rejected Ban Outgoing No outgoing calls are allowed All incoming calls are accepted This setting is Accept Any Call used when the PBX routes to the adapter a call initially directed to an extension other than
7. be connected to the local area network It is provided of two RJ11 ports to connect standard analogue telephone devices telephones or faxes These devices will be controlled by the PBX as traditional SIP extensions The V 6016 is also provided of a switch that is particularly useful in case of multiple installations 4 1 General specifications 110 220V AC Power supply OUT 12V DC 2A 1 10 100Base T RJ 45 Ports 1 10 100Base T RJ 45 2 RJ11 for telephones TET Operan lamparas o0 103mm 113mm 40mm 4 2 Main functionalities e Network protocols TCP UDP IP HTTP DHCP Client FTP TFTP e Switch port PC e VoIP protocols SIP RFC3261 RFC3262 RFC3264 RFC3265 e Voice Codec G 711 A law U law G 723 1 G 729A B e The system supports standard voice functions such as Caller ID On Hold Call Transfer Do Not Disturb DTMS Tones Hot Keys Hotline Autodial to dial a number as soon as the handset is lifted e Manual configuration through web interface or automatic through TFTP o HTTP e Remote firmware update through TFTP FTP e HTTP USER MANUAL O VOISPEED LTD 8 e Pass through fax and T 38 fax 4 3 List of components in the package e One V 6016 SIP adapter e One power supply e One Ethernet UTP5 cable with RJ 45 connectors e One RJ 11 telephone cable e User manual 4 4 Getting started Before connecting the V 6016 adapter to the network please make sure that both your network and VOlspeed server are
8. bers between 1000 and 8999 e Oxxxxxxx Any 8 digit numbers starting with 9 e 30x T4 Any 3 digit numbers starting with 30 It is also important to add a timeout at the end so that the adapter will start a call if no digits are entered within the next 4 seconds Digital map table All rules entered are displayed in the Digital Map Table To delete a rule you can simply select it from the drop down menu and press Del 6 4 2 DSP config Here you can configure the advanced settings relating to the devices connected to either lines and the protocols used Phone Port Select Select first the port whose advanced settings you want to modify and then click Load Port1 is FXS1 and Port2 is FXS2 Below are the advanced settings for each port Coding Rule Input Volume Output Volume Fax Mode USER MANUAL Audio Codec used e g 11Alaw64k e g 11Ulaw64k e g 29 Incoming audio volume level sent to the device connected to the port Outgoing volume level sent to the PBX When a fax is connected to the port here you can define the standard used e Bypass A e Bypass U VOISPEED LTD 1 6 There are some additional DSP settings that do not relate to the individual ports but affect e Relay T38 lf no fax is connected you can select Disable In case you have selected Relay T38 in the setting above here you can define how to use Fax TCF Mode TCF These are possible values e LocalT CF e rasferredT CF Caller
9. ected to the adapter The list of commands is reported in the table below Description Restarts the adapter 000 Resets network configuration 400 Setup a static IP address default address 192 168 1 179 Requests an IP address from the diis DHCP server H 144H A recorded message will notify the adapter s IP address Manual configuration of the adapter s IP address with as a separator For 50 IP example to configure 192 168 0 113 you will need to enter 50192 168 0 113 51 P Manual configuration of the Gateway s IP address as above Manual configuration of the primary pena DNS IP address as above 5O3 NE TMASK To setup the Sub net mask As default once connected to the network the device requests a valid IP address to the DHCP server It is possible to verify this IP address by typing 71112 In case the recorded message provides a null address 0 0 0 0 it means that the procedure has been unsuccessful In this case you will first need to enter the command 100 to allocate the standard IP address 102 168 1 179 On a web browser you will then need to access the following web page to reconfigure the system http 192 168 1 179 6 Configuration using the web interface It is possible to display the web interface by accessing the following web page on a web browser http IP ADDRESS The IP address is the address of the V 6016 adapter This address is generally allocated by the DHCP server A
10. lD Tx It specifies the standard used for CallerlD on Mode incoming calls Polarity This checkbox needs to be selected only if a POS Reversal device is connected to the port in question It enables echo cancellation on an analogue line Echo Canceller You should disable this option only if a FAX is Enable connected to the port DSP Configuration CodingRule g 14Alaw64k x Fax Mode Disable some main functionalities of the adapter 17 Global D5P Configuration 7729 Payload Length Signal Standard Hook Flash Timer Min DTMF Payload Type 401 When choosing the G729 codec here you can G729 Payload select the payload length Below are the possible Length values e 10ms e 20ms Signal Standard t determines the standard of analogue signalling Possible values are VOISPEED LTD VOISPEED V 6016 e United States e China Hook Flash Timer Min Max It is the delay of time between replacing and lifting the handset that determines a Flash event This event places the active call on hold and allows the user to start a second call DTMF Payload ldentification code for DTMF tones in compliance Type with the RFC 2833 standard It is recommended not to change it 6 4 3 Account config Here it is possible to modify username and password to access the adapters web interface User Set admin v To modify username or password simply click on Modify Account o
11. lternatively you need to associate a static IP address to the adapter UsER MANUAL VOISPEED LTD 10 Username Password Please consult section 5 to retrieve the IP address allocated to the device by the DHCP server or to assign the IP address manually In order to access the web interface you will need to enter a username and password As default the V 6016 offers two levels of access of the web interface The highest level will allow a complete configuration of the device Username Password High level access admin admin Low level access guest guest Username and password can be easily changed if needed 6 1 Current status In this status the system summarises the adapter s configuration settings and its internal status network connection and server PBX interface Extension number and registration status are also displayed for both ports Determines whether the IP address was allocated by the DHCP server or Connect it was configured manually in the Mode latter case the IP address will not change when the adapter is restarted IP Address V 6016 adapter s IP address V 6016 adapter s physical address MAC Address MAC Network gateway s IP address It shows if the line was correctly SIP LINE 1 registered Registered or not Failed followed by the error signalled by the PBX It also shows the extension number associated to that line SIPLINE2 WB Line 1 relates to port FXS1 and Line 2 to port FXS2
12. ons above is selected In addition to these events it is possible to define a set of rules to enable the adapter to recognise specific numbers regardless of the events above occurring Digital map table Set In the textbox you need to enter the rule in question and then press Add to save it Using the sintax explained in the table below you can describe how the adapter recognises numbers It is any number of variable length It must be used in conjunction with Tn to setup the timeout following the last digit or otherwise the call will never start It is a digit within the predefined range You can define this range using the syntax min max or alternatively by listing the digits separated by commas For example 1 5 9 means that only 1 5 and 9 are allowed whereas 1 5 means that all numbers between 1 and 5 are allowed namely 1 2 3 4 and 5 It determines the delay of time after which a call is started following the last key being pressed The value n is expressed in seconds 15 NB this value Tn must be placed at the end of the rule VOISPEED LTD VOISPEED V 6016 Some examples e 365 By dialling 365 the adapter will start a call to this number without waiting any delay This means that it will not be possible to make any calls to numbers starting with 365 It is therefore recommended to add a delay when specifying any rules similar to this in this case of 2 sec 365T2 e 1 8 xxx Any four digit num
13. remove any security devices Always disconnect the telephone from the 5 VOISPEED LTD VOISPEED V 6016 power supply during storms All maintenance work should be carried out by qualified personnel 3 8 Cleaning the device We suggest cleaning the equipment only using a slightly dump cloth 3 9 Product Disposal Our products are compliant with the European Directives 2002 95 CE 2002 96 CE and 2003 108 CE regarding the limitation of use of lead mercury cadmium chromium VI as well as some flame retardants and hazardous material within electric and electronic equipment and disposal 1 mm The sign above representing a crossed waste bin indicates that the product once no longer utilised must be disposed of by separating it from any normal waste The user must ensure that the product once reached its end life is given to qualified organisations responsible for the collection of electronic and electrical waste The user may otherwise choose to return the equipment to the manufacturer when purchasing a new equivalent device In this case the product returned must correspond to the one being purchased ouitable disposal of the equipment in accordance with relevant recycling guidelines helps the environment and fosters sustainable development Unlawful disposal of this equipment is an offence and may lead to prosecution in accordance with the Country s laws in which the disposal takes place Correct disposal benefits us
14. taking unnecessary risks 3 1 How to use the device correctly Use the device only in the standard working position 3 2 Qualified personnel Any installations or repairs on the product should be carried out only by qualified and fully trained personnel 3 3 Accessories Use only accessories that are fully approved by The Manufacturer Do not connect to any non compatible products 3 4 Waterproof guidelines The device is not waterproof Avoid contact with liquids 3 5 Connecting other devices lf you connect the device to other devices please read the user guide of the new equipment first Do not connect the device to any non compatible products 3 6 Device position Avoid prolonged exposure to direct sunlight Do not place the device near sources of intense heat e g radiators fire etc and near electronic equipment producing strong magnetic fields Speakers microwaves ovens etc Do not install the device in humid rooms and avoid contact with liquids Do not expose the device to aggressive gas and do not use it in too dusty environments Never use the device in presence of any explosive gas e g methane Refrain from opening any parts of the product and do not touch the plugs with metal or sharp objects 3 7 Connecting to power supply Please make sure that the power supply complies with the voltage setting of your equipment If you have any doubts about the voltage setting please call the technical support Do not
15. that assigned to the line in question No Answer Time Ringing time in seconds after which the adapter rejects an incoming call Call Service Setting No Answer Time seconds 20 6 4 Advanced settings In advanced settings you will find a comprehensive list of settings to personalise the use of the adapters based on your requirements PSP Config Account Config j lime Config 6 4 1 Digital Map The digital map determines the adapter s behaviour when dealing with an incoming call An analogue telephone usually transfers numbers on a line one digit at a time As this is not possible using the SIP protocol whole numbers need to be transferred This means that it is required a procedure to determine when the user has finished entering digits on the keypad UsER MANUAL VOISPEED LTD 14 End with Fixed Length 11 Time out There are three ways to determine when a number is complete selected by a checkbox The adapter starts a call to the dialled number as soon as the ash key is pressed on the keypad The adapter starts a call after a number of keys Fixed Length have been dialled This number is entered in the Time out adjacent textbox The adapter starts a call after a predetermined delay following the last key being pressed This delay between 3 and 30 sec is entered in the adjacent textbox NB no outgoing calls are allowed unless at least one of the opti
16. time No support maintenance or replacement will be provided for these components e Damages resulting from using a wrong power supply e Damages resulting from misuse or actions that do not comply with the guidelines of this manual e Damages resulting from lack of maintenance as advised by The Manufacturer e Damages resulting from installing or using the product without complying with the relevant standards legal health and safety technical etc that are in place in the Country where the product is utilised e Damages resulting from misuse negligence unauthorized product modification repair or attempted repair by anyone not authorized by The Manufacturer including the user or failure to follow instructions supplied with the product e Damages caused during product transportation or delivery due to insufficient or inappropriate packaging e Damages caused by accident fire water any acts of nature insufficient ventilation or other causes that don not fall under the control of The Manufacturer e Damages caused from any unintentional or deliberate human acts e Damages caused from manumission or in conjunction with warranty labels being broken T VOISPEED LTD VOISPEED V 6016 e Damages to Software or any Hardware component not supplied by The Manufacturer with the product This warranty is only valid within the European Community 4 General Information The V 6016 is a stand alone device that needs to
17. uration file 19 VOISPEED LTD VOISPEED V 6016 6 5 3 Auto Update Auto Update Setting Protocol Type FTF m Disable Iv It is possible to setup the adapter so that it will regularly check for updates by connecting to an external FTP or TFTP server In Update Mode you can choose whether to enable or disable this option You can otherwise configure the adapter to check for updates on a regular basis in this case you need to enter the delay in hours in Update Interval Time or only when the system restarts The latest version is displayed in Current Version Based on this version the adapter will decide whether to update to a new version or not 6 5 4 Clear Config By pressing Clear the adapter will reset to its default settings Clear Configuration Press the Clear button to Clear the configuration files Clear 6 5 5 Backup config This function creates a backup copy of the configuration file Here you simply need to right click on the link and save the file Backup Config Save all Network and VoIP settings 6 5 6 Reboot By pressing Reboot the adapter will restart Reboot Phone Press the Reboot button to reboot Phone UsER MANUAL VOISPEED LTD 20
18. working correctly NB before you can use any analogue devices connected to the V 6016 adapter you will need to create additional users at the server PBX 4 5 Installation Connections e Connect the devices LAN Ethernet port to a switch router hub using an UTP5 Ethernet cable not cross cable e Connect any devices or additional V 6016 adapters to the PC Ethernet port using an UTP5 Ethernet cable not cross cable e Connect any analogue devices telephone fax to the FXS1 and FXS2 ports e Connect the power supply to the Power plug This device is provided with a ground connection Use the device only in a fully earthed electric system with Residual Current Device RCD and relevant safety measures as prescribed by law Please also make sure that the voltage complies with that required by the device Contact technical support if in any doubts 4 6 LEDs There are four LEDs mounted on the V 6016 They display the status of the resources connected to the device The table below reports the colours associated to each resource status Green Of Flashing green LAN Local network UP Local network DOWN Data flow PC Connection UP Connection DOWN Data flow Registered user Active call Registered user Unregistered user Active call 9 VOISPEED LTD VOISPEED V 6016 5 Basic operations 5 1 Manual configuration It is possible to send commands to the V 6016 adapter by entering a sequence of keys on the keypad of the device conn