Home
EM Series_Basic_User..
Contents
1. Clarity Factor M Show Color H Default User Manual 2 Video Marker Setup gt Video Overlay gt Marker Video Overlay Overlay Type CrosstRectangle VY Cross Width Cross Height 90 90 Rectangle Width Rectangle Hei 50 50 x Offset Offset o F 0 z Rotate 0 Color E Default 25 9lum A Tece 50 71 18 16 um Angle 54 48um Point 68 87um 41 85um 58 31deg Line Parallel E 49 60um Don Two Parallels N 23 58um Vertical 31 POu Rectangle RoundRect Ellipse 60 1 Circle Annulus Two Circles G are EA 68 62um Text Polygon Z Order 2D measurement Measurement Sheet Index Name Center Radius Area Length Angle Start End Distance 1 Al 25 02 23 25 58 31 27 02 5 98 36 54 31 67 2 Fi 50 71 18 16 3 Li 101 20 22 59 54 48 0 93 128 43 22 14 73 96 23 03 4 vi 41 85 25 91 179 3 171 39 6 64 171 17 32 55 5 Ri 31 89 64 88 1537 69 161 20 56 69 80 38 7 09 49 38 6 Rri 99 09 56 58 3306 42 227 175 File Import T Ei 98 43 60 89 11 63 10 83 388 19 69 95 File Save 8 E2 171 28 59 23 23 58 20 70 1533 92 139 28 3 ci 28 49 108 02 21 53 1456 26 135 28 Export to Hind 10 Ant 17 28 108 50 26 44 22 64 585 36 166 13 142 28 H 11 Tel 16 50 16 44 855 40 849 24 103 68 103 30 149 13 120 24 99 87 179 14
2. Calibrate Magnification 10X Before definition Actual Length 1000 Pixel H 100 Ms Pixel 2868 000 Resolution 2868000 Pixel Meter Pixel After definition micron Cum 100 5098 Actual Length 3 Calibrate the gray values of image This function can make image brightness stable and uniform results with a lot of shooting or in differe nt time shooting achieve the requirement of the continuity of the shooting Method of use use the Image Select tool to select a reference region as the brightness setting in the video window background click on the menu bar input menu gray scale then pop up dialog box scroll and display current mean value of brightness and gray then adjust the brightness of microscope light source until close to the preset value click OK and finish The recommended value is 200 Acquire Edit View Image Process a Live Capture gt Gray Calibraion Video Watermark Ctrl W Move Watermark gt Average Gray Rotate Watermark gt Grey Calibration lt 5 Manual Fusion Twain Select Device Twain Acquire Special Function and tools of ToupView 1 Video Overlay Setup gt Video Overlay gt Overlay Video Overlay Position Mode Font Size Larger v Font Weight Scale M Show M Show magnification Color fl Default Date Time Type YYYY MM DD HH MM SS Second Color D Default
3. 135 08 68 62 Export to Microsoft Excel 12 rl 166 61 112 70 26 18 60 14 131 63 154 56 89 46 191 98 119 13 ace 13 Tl 92 67 143 82 v Auto Hightlight 14 Pyl 132 68 18 17 350 61 137 86 i Settings Capture and save ToupView provides a variety of image or video recording mode and can easily achieve a single picture sequence images video capture and preservation 1 Taking single picture and video During the video showing you can always use the Snap button or use the shortcut key F8 to freeze a picture can also use the Record button or use the shortcut key F9 to record movies The pictures can be saved to the specified directory by the menu bar File menu Save as leaflet and can also be saved one time through the Batch Save Note during the video it may lose frames seriously by setting resolution depending on the transmission and recording performance of computer User Manual 2 Capture a sequence of pictures Time Lapse This function can capture a sequence of pictures with the same interval of time after setting time interval you can precisely set the time interval 2 to 3600 seconds and the total number of shots Open path the menu bar Capture menu Time lapse Time lapse Auto Capture S Cancel File Capture Image Process Layer Me Name Format yyyy mm dd HH MM SS Snap F8 File Prefix m Himerlapse Auto Capt
4. If the automatic setting and actual result still has deviation turn to color adjustment manually to correct 2 The viewfinder should be placed in blank background in regulating white balance 3 In automatic exposure mode when the Exposure amp Gain property sheet is open The viewfinder marked with Exposure appear The area of viewfinder will be regarded as the reference region of judging brightness target values of the image Move it to the dark position image will be the overall light Conversely move it to lighter area image will be the overall dark 1 Set hue saturation brightness parameters according to the requirement 2 Adjust the contrast and gamma values according to the user preference and output device 4 Frame Rate Low Move the slider to the right to ensure that the camera plays live video at the fastest frame rate that the computer USB hub supports If live video fails to display move the slider to the left to decrease the frame rate I Color Gray Color Gray Ab Flip Horizontal Vertical Q Power Frequency AC 50 Hz AC 60 Hz SDC Sampling Bin skip Histogram 2 Calibrate the magnification User Manual Different frame rates are available You can select proper frame rate according to your computer performance Select the fastest frame rate if your computer is good enough If you need to observe color
5. TOUPTEK PHOTONICS and shall be required to prepay such costs TOUPTEK PHOTONICS shall use reasonable effort to repair or replace any accessory covered by this warranty within thirty days of receipt In the event repair or replacement shall require more than thirty days TOUPTEK PHOTONICS shall notify the customer accordingly TOUPTEK PHOTONICS reserves the right to replace any product which has been discontinued from its product line with a new product of comparable value and function License Agreement The software and accompanying documentation are protected by the International copyright laws Any use of this software in violation of copyright laws or the terms of this agreement will be prosecuted to the best of our ability TOUPTEK PHOTONICS authorizes you to make archival copies of this software for the sole purpose of back up and protecting your investment from loss Under no circumstances may you copy this software or documentation for the purposes of distribution to others You may not distribute modify adapt translate reverse engineer recompile disassemble or otherwise attempt to discover the source code of the Software Any information supplied by TOUPTEK PHOTONICS or obtained by you as permitted hereunder may only be used by and may not be disclosed to any third party or used to create any software which is substantially similar to the Software
6. place for future reference User Manual Warnings and Precautions Precautions when using your EM Series Microscope Camera AN Keep camera away from the following e High temperatures and excessive humidity e Direct sunlight or other heat sources e Dust e Extreme vibration If the imaging sensor lens becomes dirty first try blowing dust particles from it Next use a lint free cloth or proper lens cleaning cloth to wipe the lens gently Only use approved lens cleaning fluids Never touch the lens with your fingers Do not allow the camera to come into contact with water or any other liquid If water or a foreign substance should get in the camera unplug the camera immediately and do not attempt to plug in until after a long period of time to allow for drying This does not necessarily mean it will work again Do not open the camera case or attempt your own repairs Internal components may create risk of electrical shock or fire There are no user serviceable components inside Clean the outside of the camera by wiping with a clean dry cloth Never use harsh or abrasive cleaners or organic solvents on the camera or any of its parts If you notice smoke or a strange smell coming from the camera immediately unplug the camera and consult an authorized dealer User Manual System Requirements PC running either Windows 32 bit amp 64 bit XP Vista 2008 and 7 Mac OSX and Linux Performance is not guaranteed if the foll
7. Acrobat Reader 8 Click to select the Install Image Software the installation image software ToupView for example PF ToupView 3 4 Setup Welcome to the ToupView 3 4 Setup Wizard This wizard will guide you through the installation of ToupView 3 4 It is recommended that you close all other applications before starting Setup This will make it possible to update relevant system files without having to reboot your computer Click Next to continue 9 Click the Next 10 Click the I Agree f 7 ToupView 3 4 Setup License Agreement Sua Please review the license terms before installing ToupView 3 4 5 Press Page Down to see the rest of the agreement TOUPTEK SOFTWARE LICENSE TERMS These license terms are an agreement between ToupTek Corporation or based on where you live one of its affiliates and you Please read them They apply to the software named above which includes the media on which you received it if any The terms also apply to any ToupTek pere Fr o If you accept the terms of the agreement click I Agree to continue You must accept the agreement to install ToupView 3 4 lt Back TAgree a ToupView 3 4 Setup Choose Install Location Gun Choose the folder in which to install ToupView 3 4 gt Setup will install ToupView 3 4 in the following folder To install in a different folder click Browse
8. User Manual EM Series Microscope Digital Cameras QUICK GUIDE INSTALLATION MANUAL Version 3 5 User Manual CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO OR BAG THE Sac ER SERVICEA SHOCK DO NOT VALE RVICEABLE PARTS INSIDE G TO QU LIFIED OPLENIG SERVICE PERSONNEL REMOVE C vine REFER SERVICI The lightning flash with an arrowhead symbol within an equilateral A triangle is intended to alert the user of the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to A alert the user of the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance WARNING TO AVO ID THE RISK OF FIRE OR ELECTRICAL SHOCK N EVER EXPOSE THIS PRO DUCT TO WATER OR OPERATE IN AHIGH HU MID IT YEN VIRONME NT Keep camera away from the following High temperatures and excessive humidity Direct sunlight or other heat sources Dust Extreme vibration If the camera lens becomes dirty first try blowing dust particles from it Next use a lint free cloth or proper lens cleaning cloth to wipe the lens gently Only use approved lens cleaning fluids Never touch the lens with your fingers Do not allow the camera to come into contact with water or any other liquid If water or a foreign substance shoul
9. a T EF 200 300 400 500 600 700 Camera List UCMOS10000KPA BA Capture amp Resolution Auto Exposure Exposure Target Exposure Time kh White Balance Temperature E Measurement Sheet UCMOS10000KPA Frame Rate 18 5 Frame 814 896 x 684 Pixel 0 Pixel Camera Initialization Settings On the first use of camera for video preview the following settings are available for adjustment to make the camera work in the preset condition 1 Buttons and Icons 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 Gd B Pir Elna Go Sl Mlle 2 77GZl 0000 O V HR G 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 1 Open Ctrl O 7 Zoom 13 Track 19 Two Parallel 26 Two Circles 2 Save Ctrl S 8 Video Source Properties 14 Object Select 20 Vertical 27 Arc 3 Browse Ctrl B 9 Video Stream Format 15 Angle 21 Rectangle 28 Text 4 Camera List 10 Capture Image 16 Point 23 Ellipse 29 Polygon 5 Unit 11 Calibrate 17 Line 24 Circle 30 Manual Fusion 6 Magnification 12 lmage Select 18 Parallel 25 Annulus 31 Gray Calibration amp Capture amp Resolution x Snap O Record Live 896 684 v Snap 3584 2748 v 4 Exposure amp Gain Auto Exposure Exposure Target Exposure Time H Exposure Time Range 0 400 2000 000 ms R ms v lw White Balance a Temperature 6719 U Tint 1070 Q Move the ROI Marked by a red
10. allation Destination Folder C Program Files ToupT ek ToupCam Space required 3 6MB Space available 61 4GB fc ToupCam 2 0 Setup Installing Sua Please wait while ToupCam 2 0 is being installed Execute C Windows System32 regsvr32 exe s C Program Files ToupTek ToupCam x86 Execute C Windows System32 regsvr32 exe s C Program Files ToupTek Toup 4 Output folder C Windows twain_32 Extract ucmos05100kpa ds Output folder C Program Files ToupTek ToupCam x86 Extract ucmos08000kpa ax Execute C Windows System32 regsvr32 exe s C Program Files ToupTek Toup Output folder C Windows twain_32 Extract ucmos08000kpa ds Output folder C Program Files ToupTek ToupCam x86 Extract ucmos08000kpb ax 4 The progress of installation User Manual User Manual 7 ToupCam 2 0 Setup Completing the ToupCam 2 0 Setup Wizard ToupCam 2 0 has been installed on your computer Click Finish to close this wizard ci ee 7 Click Finish the end of the installation If using Vista please plug the digital eyepiece into the USB slot before installing camera driver and skip step 3 a ToupCam Microscope Camera ToupCam Digital Camera Solution Disk Install Camera Driver Install Image Software Driver Installation Guidance Image Software User Guide Browse the CD Get
11. and select another folder Click Install to start the installation Destination Folder C Program Files ToupTek ToupView Space required 31 9MB Space available 61 4GB ToupCam 2 0 Setup Installing Please wait while ToupCam 2 0 is being installed Extract uhccd05100kpa ds e Output folder C Program Files ToupTek ToupCam x86 Extract uhccd05000kpa ax Execute C Windows System32 regsvr32 exe s C Program Files ToupTek Toup Output folder C Windows twain_32 Extract uhccd05000kpa ds Output folder C Program Files ToupTek ToupCam x86 Extract uhccd05100kpa ax Execute C Windows System32 regsvr32 exe s C Program Files ToupTek Toup Output folder C Windows twain_32 Extract uhccd05100kpa ds ToupCam 2 0 Cancel The progress of installation User Manual User Manual 7 ToupView 3 4 Setup Completing the ToupView 3 4 Setup Wizard ToupView 3 4 has been installed on your computer Click Finish to close this wizard 7 Run ToupView 3 4 12 Click the Finish end of the installation after the success of installation the shortcut icon y ToupView will appear on the desktop Ay Connect the camera to a Microscope The left hand holds the camera and makes the dust cover down the right hand rotate the dust cover clockwise Keep the interface vertically downward in the process Connec
12. cified error O aA A O Fault reason The light source of the microscope is closed The position of the splitter lever of the microscope is in the wrong position to make the photography channel closed The preset exposure time is too short USB cable disconnects accidentally USB cable connection is bad or lack of power supply The driver is not installed properly Image motion lag slow moving Fault reason Preview resolution is set too high Light source is closed or lighting level is inadequate automatic exposure mode The preset exposure time is too long manual exposure The preset frame rate is low Computer performance does not meet the requirements Color noise on the screen Fault reason Analog gain value is too large and lighting is poor The exposure time setting is too long use continuously long exposure for a long time The brightness of light is too low beyond the camera ability User Manual Solution Open light source and adjust the brightness Switch the splitter lever to open to photography channel Reset the exposure time Reconnect and open video Change to another USB interface or USB cable Reinstall the driver Solution Set the smaller size for video preview resolution Cancel auto exposure open or increase the brightness of light and shorten the exposure time Shorten the exposure and increase the brightness of light Adjust the frame rate in the Frame Rate proper
13. d get in the camera unplug the camera immediately and do not attempt to plug in until after a long period of time to allow for drying This does not necessarily mean it will work again Do not open the camera case or attempt your own repairs Internal components may create risk of electrical shock or fire There are no user serviceable components inside Clean the outside of the camera by wiping with a clean dry cloth Never use harsh or abrasive cleaners or organic solvents on the camera or any of its parts If you notice smoke ora strange smell coming from the camera immediately unplug the camera and consult an authorized dealer User Manual Trademark and Copyright information COPYRIGHT 2012 TOUPTEK PHOTONICS All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of TOUPTEK PHOTONICS The information contained in this document is subject to change without notice TOUPTEK PHOTONICS shall not be liable for errors contained herein or for consequential damages in connection with the furnishing performance or use of this material Microsoft and Windows are U S registered trademarks of Microsoft Corporation Welcome Thank you for buying EM Series high quality digital cameras We suggest you spend a few minutes carefully reading this user manual before installing and using your camera Please keep this user manual in a safe
14. image select Color If you need to observe black and white image select Gray If the image on the screen appears in different direction from what is viewed under the microscope check the level and vertical option to correct screen square Choose the right light source power frequency Optional sampling mode in low resolution Bin or Skip Bin will allow more sensor sensitivity and Skip will give faster video frame rate Histogram property 1 By dragging the pink line on both sides of the histogram to the proper position the histogram distribution of image is changed make the contrast and brightness curve of image improved 2 You can also input directly the accurate value in the number box of chart and make extension of histogram 3 Click Refresh button to update the histogram information if the vision is moved or the scene is changed Put the TS M1 stage micrometer in the view field and find the scale set the live resolution Max and zoom to 100 display Click on the Calibrate button and a red line calibrate tool appeared Put the 2 ends of the red line on the scale measuring the scale corresponding to the pixel value Select or input the magnification of current objective and input the actual length of the selected scale in the pop up dialog box Click the OK button to finish the magnification calibration User Manual Live 3584 2748 z swp Saas 3 B
15. ons before starting Setup This will make it possible to update relevant system files without having to reboot your computer A Click Next to continue ToupCam 2 0 Setup License Agreement Sua Please review the license terms before installing ToupCam 2 0 gt Press Page Down to see the rest of the agreement TOUPTEK SOFTWARE LICENSE TERMS These license terms are an agreement between ToupTek Corporation or based on where you live one of its affiliates and you Please read them They apply to the software named above which includes the media on which you received it if any The terms also apply to any ToupTek PEN Fr Ne If you accept the terms of the agreement click I Agree to continue You must accept the agreement to install ToupCam 2 0 lt 8ack tAgree User Manual 3 ToupCam 2 0 Setup Choose Products Sua Check the products you want to install and uncheck the products you don t want to install Click Next to continue Select products EAE UCMOS Series H UHCOD Series EM EXCOD Series 7 EXCCD01400KPA Space required 3 6MB a ToupCam 2 0 Setup Choose Install Location ne Choose the folder in which to install ToupCam 2 0 gt Setup will install ToupCam 2 0 in the following folder To install in a different folder click Browse and select another folder Click Install to start the inst
16. owing specification cannot be reached A DirectX 9 0 or later installed 2 0 GHz minimum processor Recommend dual core 2 8GHz or more USB 2 0 Port CD ROM drive 2GB RAM Recommend 2GB or more 200 MB Free HDD Performance is dependent on the PC s graphics card USB 2 0 is supported on Windows XP 2003 Vista 2008 and 7 also Mac OSX Linux Kernel 2 6 or Above Windows XP Pro must have Service Pack 2 or later installed in order for the camera to function correctly To check if you have USB2 0 installed on your computer goes to Start gt Settings gt Control Panel gt System or right click on My Computer and select properties from the context menu Click on the Hardware tab and then onto the button Device Manager Within Universal Serial Bus controllers USB controllers you will see a list of USB devices installed on your machine In this example the red arrow is indicating the USB2 0 device USB2 0 controllers may be labeled as USB2 0 controllers however they may also be labeled as Enhanced or Standard Enhanced controllers The so called Standard or Standard Universal controllers are for the slower USB1 x system a ia Sh res frn i Standard Universal PCI to USB Host Comroller Intern ER CHS j kla USE Enhanced Hosi Controller hen Controller oat Controller USE Root Hub User Manual Package Contents If you find any contents missing or damaged contact the
17. place of purchase CO 5 As 2 NA Software CD USB Cable Manual Calibration slide D 3 ce Lens adaptor for USB Cable eyepiece tube 90 connector Fixed Focusable 1 lens adaptor Lens adaptor CS Mount Ring marked parts are optional accessories ToupSee is a free basic software supporting DirectShow and Twain interface which can facilitate the video preview preservation video record and picture management operation ToupView Advanced measurement and analysis is available for option at extra cost Not in the standard package ToupSee ToupView Product safety information This product is in compliance with the low voltage EMC Health and Safety Regulation 26 95 EC EN62471 2008 2004 108 EC EN61326 1 2006 EN 61000 3 2 2006 A2 2009 EN 61000 3 3 2008 Installing the Driver and Software 1 Insert CD into CD ROM drive the CD Autorun will pop up the start interface 2 Select Install Camera Driver 3 Select Next 4 Select I Agree a ToupCam Microscope Camera ToupCam Digital Camera Solution Disk Install Camera Driver Install Image Software Driver Installation Guidance Image Software User Guide Browse the CD Get Acrobat Reader A ToupCam 2 0 Setup Welcome to the ToupCam 2 0 Setup Wizard This wizard will guide you through the installation of ToupCam 2 0 It is recommended that you close all other applicati
18. rectangle to a pure white or gray object and click White Balance to establish the white balance for future video See White Balance Exposure 7 viewfinder amp Color Adjustment x Hue 0 Saturation 128 Dj Brightness 0 Dj Contrast 0 Dj Gamma 100 I User Manual Snap Capture single image Record Capture video stream Resolution settings Choose suitable resolutions will get both smooth video and high resolution still images 1 Advanced users unselected automatic exposure button enter the manual exposure mode 2 Tune the microscope light source to a bright state and then pull exposure time block left and right until the brightness of the image is in the best visual effects If and only if the microscope light source brightness can not meet the demand of imaging increase the analog gain value appropriately in order to meet the requirements for increasing the brightness 3 You can also input precise exposure time in the pop up dialog box Region of interest property 1 Click the White Balance bar to open the property sheet and the view finder appears in the preview window marked with White Balance You can drag the mouse to move the viewfinder image to find the region of concern If the viewfinder is placed in the blank background click on White Balance button the software regard background area selected as white reference for calibration of image color parameters
19. t the camera with the optical adaptor of microscope photography channel note try to keep the camera and adaptor in a horizontal position during the installation to prevent tiny dust due to friction to pollute camera sensor surface and optical center of lens of internal interface To Connect Camera Connect the USB cable into a free USB slot on the computer Requires USB 2 0 interface A New Hardware Found or Installing device driver software displays at the bottom right of your PC screen The camera is recognized gt The found new hardware wizard would start Select Install the software automatically I Installing device driver software gt oA UCMOS10000KPA x Click here for status Device driver software installed successfully gt Finish If unidentified publisher Windows Logo Testing appear select continue anyway NOTE 1 Plug the USB connector to board USB2 0 port directly on the back of the PC is recommend 2 Do NOT use anything to extend the USB cable User Manual Using the camera 1 Double click on the desktop icon and start ToupView 2 If the camera is connected with the computer correctly click the device on the camera list of left sidebar and then preview window will be open File Edit View Setup Capture Image Process Layer Measurements Plugin Options Window Help Sd B Pie Elm El Haaman 2 774 41 0000 OP V OR EG Camera vg
20. ty Use computer with high performance Solution Reduce the gain and increase the brightness of the light source set gain to the minimum if the brightness Is sufficient Long exposure function will lead to thermal noise of the photosensitive chip if the camera without refrigeration device it is recommended to shortens working time Switch to a more sensitive camera such as the EXCCD series If you have any other problems please visit our website to get help information http www touptek com User Manual Warranty TOUPTEK PHOTONICS Three Year Limited Warranty TOUPTEK PHOTONICS warrants its products to be free from the date of purchase this product for three years TOUPTEK PHOTONICS will repair or replace such product or part thereof which upon inspection by TOUPTEK PHOTONICS is found to be defective in materials or workmanship As a condition to the obligation of TOUPTEK PHOTONICS to repair or replace such product the product must be returned to TOUPTEK PHOTONICS together with proof of purchase satisfactory to TOUPTEK PHOTONICS All returns must be accompanied by a written statement setting forth the name address and daytime telephone number of the owner together with a brief description of any claimed defects Parts or product for which replacement is made shall become the property of TOUPTEK PHOTONICS The customer shall be responsible for all costs of transportation and insurance both to and from the factory of
21. ure File type png Option Start Record F9 Sample 2012 02 08 10 20 46 png Time slot second 6 v Limit the total times 100 The file name saved automatically can be a serial number or the date and time and can be coupled with the prefix There are a variety of file storage format available For example when choosing JPG format you can set the parameters of Options and adjust compression quality of pictures saved Trouble Shooting WARNING Please do not attempt to open the camera case There are no user serviceable parts inside USB Device Conflicts When there are a number of USB devices installed at the same time unexpected errors can arise The cause can be insufficient available USB bandwidth or possibly too much combined current being drawn by USB devices To test for these conditions you should uninstall and unplug as many other USB devices as possible This should help to rule out the above and eliminate possible conflicts with other cameras If you are using an extended USB cable please make sure the cable s bandwidth is good enough to support High Speed USB 2 0 standard Once the camera is not working well please remove it Image Preview Is Black Screen Capture Problems If communication fault of the camera and computer occurs the error message Error o Error during capture please re plug the device or try another USB port and try again hr 0x80004005 Unspe
Download Pdf Manuals
Related Search
Related Contents
Descargar documento PDF - Revista Técnica Pecuaria en México User Manual - VIAIR Corporation DZK – User Manual Planar Systems PLL2770W Samsung SGH-X650 Kullanıcı Klavuzu Télécharger le document Copyright © All rights reserved.
Failed to retrieve file