1. IMS id do EN NE 13 o EES 16 9 Digital Weigh TEEN 18 10 Maintenance schedule amp Daily check let 22 11 Technical Specilications m cai aaa eee iata gal ai d a ala 23 12 ele RE EE EO le ei oa 26 2 294000 10046 Rev A Oxford Hoyer EMS Elevate 1 The Oxford Hoyer Elevate Patient Lift Push Handle Digital Weigh Spreader Bar Scale optional Cow horns Battery Control Pack Sling Attachment Electric Actuator Points Adjustable Knee Pad Rear Castor SS braked Removable Foot Plate Front Castor non braked 3 294000 10046 Rev A Oxford Hoyer Endlich Elevate ngirs 4 2 Introduction About Your Lift The Oxford Hoyer Elevate is an electrically operated patient lift Each Elevate lift is fully assembled load tested and certified before being packed shipped The packing consists of a strong purpose built carton that is used for both export and domestic markets to ensure the safe arrival of the lift A number of documents are supplied in a wallet and packed with each lift and should be kept safely for future reference e USER MANUAL DEALER GUARANTEE CARD Europe only CUSTOMER SATISFACTION CARD Europe only e PACKING CHECK LIST The TEST CERTIFICATE is an important document and will be required for your insurance records It is valid for six months and after it has expired the lift should be inspected and serviced per the maintenance schedule Servicing
2. Please read and follow the safety precautions listed below The operation and use of Oxford Hoyer patient lifts is simple and straightforward Following these few basic safety precautions will make lifting operations easy and trouble free READ AND UNDERSTAND THE USER INSTRUCTION MANUAL BEFORE USING YOUR ELEVATE AWARNING e ALWAYS plan your lifting operations before commencing e ALWAYS carry out the DAILY CHECK LIST before using the lift ALWAYS familiarise yourself with the operating control and safety features of a lift before lifting a patient DONOT use a sling unless it is recommended for use with the lift e ALWAYS check the sling is suitable for the particular patient and is of the correct size and capacity e NEVERuse a sling which is frayed or damaged e ALWAYS fit the sling according to the instructions provided user instructions e DONOT exceed the safe working load e ALWAYS check the safe working load of the lift is suitable for the weight of the patient e ALWAYS carry out lifting operations according to the instructions in the user manual e ALWAYS utilise the foot tray when standing or sitting a patient NEVER disconnect or bypass a control or safety feature because it seems easier to operate the lift e DONOT lift a patient with the castor brakes on Always let the lift find the correct centre of gravity e DONOT attempt to manoeuvre the lift by pushing on the mast boom or patient e ALWAYS manoeuvre
3. and periodic testing can be carried out by your authorised supplier Please ensure your lift is included in their maintenance schedule If you are at all unsure what your local market servicing requirements are please check with your dealer and or a local government agency The Oxford Hoyer Elevate is suitable for the following CATEGORIES of lift within the working parameters of the lifts specified in the TECHNICAL SPECIFICATIONS e Category A Wheelchair e Category D Toilet Shower Chair 294000 10046 Rev A Enalish Oxford Hoyer ngirs Elevate 3 Assembly and Commissioning Instructions CARTON CONTENTS Place the carton in a clear working area and open carefully The carton contains OXFORD HOYER ELEVATE LIFT WALLET CONTAINING DOCUMENTS HAND CONTROL BATTERY PACK CHARGING LEAD DESK TOP CHARGER STAND A WARNING The Oxford Hoyer Elevate is heavy and will need to be lifted with care You may need assistance to lift the Oxford Hoyer Elevate from the carton ASSEMBLY Remove the Elevate from the carton and place on the floor 5 294000 10046 Rev A Oxford Hoyer Enalish Elevate RI 1 Tighten the mast assembly with the mast locking device which is located at the front of the chassis 2 Turn the locking knob until hand tight 3 Line the handle assembly up to the mast and attach using the fasteners provided these can be found in the mast The wrench needed to attach the
4. and raise up buttons are provided at the front of the control box This is operated by inserting a ballpoint pen into the button highlighted SW This will bring the boom up or down should the handcontrol fail at any time NOTE This is an emergency device and not intended for repetitive use 6 Mechanical Emergency Down In the case of a complete electrical failure the electrical actuator is fitted with mechanical lowering device RED BOSS This will only operate when the lift is under load The device must be pulled upwards to activate and a slow decent will commence NOTE This is an emergency device and not intended for repetitive use 7 Batteries The batteries are protected from deep discharge by a LOW VOLTAGE ALARM This will sound when the batteries need recharging and the handcontrol is being operated It will not sound independently of the handcontrol being operated DO NOT IGNORE THIS WARNING ALARM Complete the lifting operation and place the battery on charge see charging instructions AWARNING Battery or charger is not to be opened by unauthorized personnel Contact your distributor for warranty and repairs 14 294000 10046 Rev A En ale Oxford Hoyer HI Elevate 8 Slings The Oxford Hoyer Elevate is suitable for patients in the SITTING position The slings suitable for this device are the Oxford Hoyer Standing sling and Transport sling as detailed in section 4 Sling Guide 9 Knee pad adjustm
5. safe working condition A list of spare parts is available upon request The LOAD TEST and certification should only be carried out by qualified personnel or an authorised service agent dealer DAILY CHECK LIST Joerns Healthcare strongly recommends the following checks be carried out on a daily basis and before using lift e MAKE sure the lift moves freely and all 4 castors touch the floor e EXAMINE the spreader bar cow horns is firmly attached to the boom e EXAMINE the sling hooks and attachment clips on the cow horn and boom for excessive wear MAKE sure the legs open and close correctly e OPERATE the hand control to confirm the boom raises and lowers satisfactorily e CHECK the operation of the emergency stop button e EXAMINE slings for fraying or other damage DO NOT use any sling if damaged e CONFIRM the lift is not giving a low battery alarm when the hand control is operated If the alarm sounds DO NOT use and place on charge immediately MAINTENANCE INSPECTION AND TEST Joerns Healthcare recommend a thorough inspection and test of the Oxford Hoyer Elevate lift and lifting accessories slings scales etc is carried out on a regular basis Inspection frequency varies from country to country so you must check with your dealer or local government agency as appropriate regarding how often an inspection is required The examination and test should be conducted according to the recommendations and procedures below Joerns Healthcar
6. 0 1 Ibs 59 kg without scale 129 lbs 58 5 kg ae Vd 2 ie SEE atita 6 6 lbs 3 kg ec RO ss EE 136 7 Ibs 62 kg without scale ee ee RR RR ek Ge Ee RR 135 6 Ibs 61 5 kg Base Assembly not inc hatten 40 8 Ibs 18 5 kg Mast amp Boom not inc battery with scale 66 1 Ibs 30 kg without scale 65 Ibs 29 5 kg EO I N OR OE N 23 1 Ibs 10 5 kg All measurements are within a 5 5 degree of tolerance 23 294000 10046 Rev A Oxford Hoyer Enalish Elevate RI ELECTRICAL SPECIFICATIONS BAT TE RIE see ee e il et ant ata ee 24 volt Rechargeable sealed lead acid type BATTERY CAPAC Yo ase ee ene amante ea 3 2 Ampere hours CHARGER RATED INPUT see ee ee ee ee ee ee ee ee ee 100 240 V AC 24 VDC 50 60 Hz CHARGER RATED OUTPUT eer 29 5 VDC Max 19 W Electric Shock Protection e EE CLASS II El cita bu la i Sal n o a ie INTERNAL POWER SOURCE Degree of Shock Protection CHARGER m se sies a ra i ga e a a f TYPE B LEU RT ai ER o ai Ra TYPE B ENVIRONMENTAL CONDITIONS Outside this environment functionality and safety may be compromised Operating Temperature setei ae a ai ia OO EE N 5 C to 40 C Relative humidity EEN 20 to 90 30 C not condensing Atmospheric pressure ee ee ee ee ee Ak RA N AR EA 700 to 1060 hPa Storage Rude 10 C to 50 C Relative humidity EEN 20 to 90 30 C not condensing Atmospheric pressure eee 700 to 106
7. 0 hPa IP RATINGS Boys ee XC da esas etic MEE EE cau ie poa at IP43 ACUO EE IP54 Off Board Charger scosi oa coada da aie IP65 BEG RAT a aa em aa i a pi ti IP65 alie JA N EE EN IP65 DUTY CYCLES PEAT notifica EE 10 2 min 18 min E ce EE EE N Approx 4 hrs ACOUSTICS A Weighted sound power level assesseer 55 6 dB A 24 294000 10046 Rev A En ale Oxford Hoyer ngirs Elevate KEY SYMBOLS The following symbols are used on the charger control unit and battery O Type B equipment as per EN 60601 1 El Class 2 equipment NM S d The disposal of the charging and control unit should not be mixed with general household waste SWZ e The disposal of batteries should not be mixed with general household waste Lx li For indoor use ATTENTION consult accompanying documents gt 25 294000 10046 Rev A Oxford Hoyer Endlich Elevate ngris 26 12 Warranty Joerns Healthcare has an established network of reputable distributors and dealers who will be pleased to handle all your purchasing warranty repair and maintenance enquire Our products are guaranteed for a period of 24 months from the date of manufacture or 24 months from the date of purchase if commissioned by an authorised dealer This guarantee covers the lifts major structure actuator and control box handset and battery for manufacturing defects failures We recommend that all of our products are com
8. Oxford Hoyer Oxford Hoyer Elevate User Instruction Manual amp Warranty To avoid injury read user manual prior to use Oxford Hoyer Elevate Manuel de l utilisateur et garantie Afin d viter tout accident veuillez lire attentivement la notice avant utilisation Oxford Hoyer Elevate Manual de Instrucciones y Garantia para el Usuario Para evitar posibles dafios lea previamente el manual de usuario Me Oxford Hoyer Elevate Benutzerhandbuch und Garantie Um Verletzungen zu vermeiden lesen Sie bitte die Gebrauchsanweisung vor der ersten Benutzung HI Joerns BMHealthcare CH Redefining patient handling Oxford Hoyer lek Elevate ngirs Mianufacturer s Contact Details Oxford Hoyer EUROPE USA Joerns Healthcare Ltd Joerns Healthcare Inc High Street Wollaston Stourbridge 5001 Joerns Drive Stevens Point West Midlands DY8 4PS Wisconsin 54481 5040 ENGLAND 715 341 3600 44 0 1384 44 66 22 800 826 0270 Fax 44 0 1384 44 66 01 Fax 800 457 8827 www joerns co uk www joerns com Contents 1 Oxford Hoyer Elevate Patient LIT se se eee eee enma en eee anna cae 3 2 Introduction About Your Im 4 3 Assembly and Commissioning Instructions nene eee aan 5 A EE el RA OE aan Rs ti i ER a 9 5 Lifting with the Oxford Hoyer Elevate se se ee se se ee RR ee Ge ee ee Ge ee Re Ge ee ek ee Rek ee ee 11 6 Safety Precautions i si on ani ali ee ee eN Ge De ia al ede E 12 1 Operating
9. ch the support straps around the front of the patient This strap need not be tight It is there to hold the sling in position whilst attaching the sling to the Standaid It may be left off altogether if preferred Ensure that the patients arms are outside the sling AWARNING Oxford Hoyer slings and lifters are not interchangeable with other manufactures products Using other manufacturers products on Oxford Hoyer products is unsafe and may result in serious injury to patient or caregiver AWARNING Joerns Healthcare recommends slings are checked regularly and before use for fraying or damage DO NOT use slings that are worn or damaged 10 294000 10046 Rev A Enalish Oxford Hoyer ngirs Elevate 5 Lifting with the Oxford Hoyer Elevate Position the Elevate so that the patient s feet fit in the foot tray and knees rest against the knee pad Attach the loops of the sling to the hooks at the end of the Elevate hand grips The patient s hands should be placed on the handgrips see Fig A or C Then push the UP button on the hand control to raise the patient to the standing position see Fig B or D STANDING SLING AWARNING Always utilise the foot tray when standing or seating a patient Once the patient is in a standing position the foot tray may be removed for gait training 11 294000 10046 Rev A Oxford Hoyer Fottoen Elevate 9 6 Safety Precautions
10. e 9 1 Leg adjustment The legs on the Oxford Hoyer Elevate are electrically adjustable for width The legs can be opened to enable access around armchairs or wheelchairs For transferring and negotiating narrow door ways and passages the lift legs should be in the closed position Electric leg adjustment is achieved by pressing the appropriate buttons on the handcontrol The legs will be locked whenever the handcontrol switch is released 2 Castors and Braking The lift has two braked castors which can be applied for parking When lifting the castors should be left free and un braked The lift will then be able to move to the centre of gravity of the lift If the brakes are applied it is the patient that will swing to the centre of gravity and this may prove disconcerting and uncomfortable 3 Raising and lowering the boom The movement of the boom is achieved by a powerful electric actuator which is controlled by a simple handcontrol unit The handcontrol has two buttons with directional arrows UP and DOWN AY The actuator stops automatically at the limit of travel in both directions The handcontrol plugs into a socket at the base of the control box 4 Emergency Stop The red Emergency Stop Button is located on the front of the control box and is activated by pressing in This will cut all power to the lift and only be reset by twisting the button anti clockwise and releasing 5 Electrical Emergency Down Up Emergency lower down
11. e recommends maintenance inspection and certified testing is carried out by authorised service agent dealers only CLEANING All Oxford Hoyer lifts will when necessary require cleaning The Oxford Hoyer lifts can be cleaned with warm water or a disinfectant cleaning fluid CAUTION Harsh chemicals may dull or remove the paint finish from the lift AWARNING DO NOT spray or submerge the lift in any liquid 22 294000 10046 Rev A EIER Oxford Hoyer ngirs Elevate 11 Techinical Specifications Safe Working Load sms catea ec a a a 440 lbs 200 kg Maximum Overall Length 43 3 inches 1100 mm Minimum Overall eng 41 0 inches 1040 mm Maximum Overall Height ere 65 5 inches 1665 mm Minimum Overall Hegoht ere 48 4 inches 1230 mm Maximum Height to attachment point 64 7 inches 1644 mm Minimum Height to attachment pont 39 2 inches 995 mm dig ede GIE ca e aa ala 48 2 inches 1225 mm Legs Open External Wd 39 1 inches 995 mm Legs Open Internal With 34 3 inches 870 mm Legs Closed External Width eee 24 8 inches 630 mm Legs Closed Internal Wu 20 0 inches 510 mm Widest Point between support handles 29 0 inches 738 mm Overall Height of Les 4 7 inches 120 mm Ground Clearance eee ee eee ee ee 1 4 inches 35 mm Goebel 4 0 inches 100 mm Rear Braked Caetors EEN 4 0 inches 100 mm Weights Mast Base amp Boom Assembly with scale 13
12. ent The Elevate has an adjustable kneepad It is recommended for safety reasons that adjustment is carried out by holding the top of the adjustment handle The range of travel is approx 7 inches Adjustment is achieved by following two easy steps STEP 1 pull handle towards you STEP 2 either push handle downwards or pull handle upwards to select the kneepad position Once the ideal position is found release handle and the kneepad will automatically lock into position 10 Removable footplate The Elevate has a removable footplate To remove the footplate move to the front of the product and lift the footplate upwards from the middle of the assembly see Fig E Additionally you can also remove the footplate cover to aid in cleaning and disinfecting of the footplate area This is achieved by removing the footplate and unclipping the cover from the back of the footplate see Fig F NOTE Be careful when lifting the footplate from its low seated position AWARNING Always utilise the foot tray when standing or seating a patient Once the patient is in a standing position the foot tray may be removed for gait training 15 294000 10046 Rev A Oxford Hoyer olie Elevate ng is 8 Charging Instructions The batteries are located in the battery pack and are charged via an off board desktop charger unit Hand Control Legs Open Close Boom Raise Lower Control Box Emergency Stop Raise Lower When the battery pack
13. ents weight When the HOLD sign appears the weight can be recorded AWARNING To restart the scale be sure to push the ON ZERO If the scale starts and the pad is pushed again the scale may go to zero 0 0 and the patient s weight may be lost This may require the reweighing of the patient 4 The RECALL feature is designed to retain in the memory the last stable weight over 10 kg 22lbs To access this weight the scale must be on Press the RECALL pad The display will flash between RECL and the retained weight MAINTENANCE It is recommended that twice yearly inspections of the connections on the scale be scheduled and performed to assure trouble free operation Look for wear or any irregularities that may contribute to scale failure If any wear or irregularity is seen DO NOT USE THE LIFT and call a competent engineer to access the assembly TECHNICAL SPECIFICATIONS Electronics Microprocessor controlled Power 9 volt alkaline battery PP3 e Battery life Exceeds 70 hours continuous operation e Display LCD liquid crystal display 63 X 18 mm Characters 15 mm high e Weighing units Kilograms kgs or Lbs and kgs North America only e Load cell Rated at 300 kgs 660 Ibs AWARNING Do not exceed the safe working load of the lift 19 294000 10046 Rev A Oxford Hoyer Endlich Elevate 9 A 9 volt battery powers the Oxford Hoyer Electronic Digital Scale A new battery should provide approxima
14. handle is kept in the user instruction wallet for safe keeping CAUTION Ensure that the handle is secure and in place prior to using lift 6 294000 10046 Rev A Enalish Oxford Hoyer ngirs Elevate 4 Fit power pack to the lift and make sure the latch holding the pack in place is fully engaged Click in place 5 Fit the hand control to the lift as shown Once complete check the hand control is functioning correctly by referring to page 8 DISASSEMBLY The lift should not be disassembled unless for service repair or transport if necessary Therefore follow the assembly instructions in reverse sequence if 294000 10046 Rev A Oxford Hoyer Enalish Elevate RI ALWAYS CHECK THE FOLLOWING BEFORE OPERATION e The mast is fully locked into position 8 294000 10046 Rev A En ale Oxford Hoyer ngirs Elevate 4 Sling Guide The Oxford Hoyer Elevate is suitable for patients in the SITTING position The slings suitable for this device are listed as follows Oxford Hoyer Transport sling Oxford Hoyer Standing sling USER GUIDE FOR STANDAID SLINGS The Transport and Standing sling is an easy fit sling suitable for standing and supporting It is not a general purpose sling and patients must be assessed for suitability by a qualified person Transport Sling Attachment Loop Straps Shoulder Chest Supports and Buckle Leg Supports Attachment L
15. missioned by your dealer and are supported by them for future servicing The dealer or distributor operates the warranty Programme so it is important to keep a record of their name address and telephone number so they can be contacted should any problem arise Failure to comply to the lifts servicing schedule may result in your warranty being invalid If you are in doubt where your lift was purchased Joerns Healthcare can trace the supplier if you quote the serial number of the lift REMEMBER Contact your distributor for purchases warranty repairs servicing and certified maintenance Your distributor 294000 10046 Rev A Oxford H j English xford Hoyer Mm Elevate 27 294000 10046 Rev A Joerns Healthcare Inc Joerns Healthcare Ltd 5001 Joerns Drive High Street Wollaston Stevens Point WI 54481 5040 Stourbridge West Midlands USA DY8 4PS 715 341 3600 ENGLAND 800 826 0270 44 0 1384 44 66 22 Fax 715 341 3962 2008 Joerns Healthcare 294000 10046 Rev A
16. needs charging it is removed from the lift and fitted to an off board charging unit 1 Remove the power pack from the lift The pack is retained by a simple latch at the top of the power pack Lift the latch and the power pack will be released 2 Fit the power pack to the charging unit The location and latching of the power pack to the charger is the same system as used on the lift 3 Plug the charger mains plug into a suitable mains outlet and switch the mains supply ON 4 Charging is automatic and will fully charge the batteries over a period of eight to twelve hours Note Even if the charger is left plugged in for extended periods it will not allow the batteries to overcharge 5 To return the lift to service disconnect power supply remove the power pack from the charger Fit the power pack to the lift and make sure the latch holding the pack in place is fully engaged Click in place The charging of Oxford Hoyer electric lifts is simple and straightfor ward but it is important to follow the charging instructions closely Please pay particular attention to the following warnings they will help you avoid problems with discharged batteries 16 294000 10046 Rev A En ale Oxford Hoyer ngirs Elevate AWARNING Battery or charger is not to be opened by unauthorized personnel Contact your distributor for warranty and repairs AWARNING DO NOT touch battery charger terminals AWARNING KEEP the batteries full
17. ommendations are in compliance with the requirements of 1998 No2307 Health and Safety The Lifting Operations and Lifting Equipment Regulations 1998 This is a UK regulation Outside the UK please check your local requirements Important Note Europe Requirement Only The Oxford Hoyer Weigh scale is a class 3 compliant weighing device and conforms to the NAWI Directive 90 384 EEC and has been certified by the National Weights and Measures Laboratory NOTE Scale is calibrated prior to shipment This certifies the scale for twelve months Joerns Healthcare s advice is that you contact your local trading standards or government authority for your nearest authorised body who can advise upon recalibration 20 294000 10046 Rev A Enalish Oxford Hoyer RI Elevate THESE CHECKS SHOULD INCLUDE Before Use Initially Service Intervals BOOM Check the attachment of the boom to the mast Make sure there is only minimal side movement of the boom and the boom is free to rotate on the boom bearing MAST Check the operation of the mast locking device Make sure the mast fully engages into the socket Check the bottom actuator ACTUATOR The actuator should require no maintenance other than checking for correct operation and listening for unusual noise POWER PACK Check the function of the emergency stop button and emergency lower BATTERIES The batteries are housed in the power pack and should not require maintenance
18. oop Straps Legs i Feed the sling down the back of the patient leaving the top of the commode aperture at the base of the spine Check the roll part of the sling is square across the patient s back Attach the support strap around the chest of the patient This strap need not be tight It is there to hold the sling in position whilst attaching the loops to the Standaid It may be left off altogether if preferred Ensure patient s arms are on the outside of the sling Raise the patient s leg and feed the leg strap under and up between the legs Ensure the sling is not twisted or creased under the thigh Repeat this procedure for the other leg Attach the loops on the roll parts of the sling to the white hooks at the end of the hand grips Without crossing the loops on the leg straps attach to left and right black knobs on the lifting fork You would normally use the middle of the three loops The patient is now ready to be raised from the seat Once clear of the seat the patient will be more comfortable if lowered back in to the sit ting position NOTE Joerns Healthcare recommends slings are checked regularly and before use for fraying or damage Do not use slings that are worn or damaged 9 294000 10046 Rev A Oxford Hoyer Enalish Elevate ngirs Standing Sling WW Attachment Loop Straps Chest Support Place the sling down behind patient s back between base of shoulder blades and bottom of rib cage Atta
19. other than the regular charging as detailed in the charging instructions Check that the connections remain clean LEG ADJUSTMENT Check the legs operate in both full extensions inward outward CASTORS Check all castors for firm attachment to the legs Check for free rotation of the castor and the wheels CLEANING Clean with ordinary soap and water and or any hard surface disinfectant Harsh chemical cleaners or abrasives should be avoided as these may damage the surface finish of the lift Avoid wetting any of the electrical parts LOAD TEST The load test should be carried out in accordance with the manufacturer s test procedures It is strongly recommended the testing is carried out by an authorised service dealer BASEAND WHEELS Ensure base is even and level all four wheels are on the floor SLINGS Check for wear and fraying LUBRICATION Lubricate pivot joints including mast and boom connections pedal assembly spreader bar joint only if required you can use silicone grease spray HAND SET Ensure plugged fully into controller 21 294000 10046 Rev A Oxford Hoyer Endlich Elevate 9 10 Maintenance Schedule amp Daily Check List All Oxford Hoyer products are designed for minimum maintenance however some safety checks and procedures are reguired A schedule of DAILY tasks are detailed below Daily checks and a six monthly service inspection and test will ensure a lift is kept in optimum
20. sition The CE mark Europe Only The Oxford Digital Scale carries the CE mark and complies with the following EC Directives Medical Device Directive 93 42 EEC EMC Directive 89 336 EEC Low Voltage Directive 73 23 EEC NAWI Directive 90 384 EEC OPERATING INSTRUCTIONS The Oxford Hoyer scale has been designed and certified to weigh up to 200kg or 440lbs in 0 2 increments NOTE For customers or users in North America your scale will measure in either Lbs or Kgs For all other countries outside NA your scale will weigh in Kgs 294000 10046 Rev A En ale Oxford Hoyer HI Elevate To weigh a patient follow the instructions below 1 Assemble the sling to the cow horn and press the ON ZERO pad The display will show 0 0 and the word HOLD will appear in the lower left hand corner This step prepares the scale for weighing The sling can now be removed from the cow horn or cradle and placed around the patient N Place the sling around the patient ensuring the patient s feet are in the foot tray Attach the sling to cow horns and raise the patient so that they are in the standing position They must not be touching anything such as a chair or bed since this will cause an error in weighing oo The scale has been designed to turn itself off after 60 seconds to conserve battery life To restart the scale push the ON ZERO pad once only The display will show the start up screen and then show the pati
21. tely 3000 readings before needing replacement When it needs to be replaced a B will appear on the display To Replace Battery Push black pad on bottom of unit to left Battery holder will slide out Remove old battery and replace with a new one Push holder back into scale ae MY g OPERATION FEATURES All functions are accessible to the user without opening the case e Starting or zeroing the scale is done through a single touchpad located on the front of the case Stable readings are achieved through digital averaging The HOLD message is activated when weight fluctuations decrease to a predetermined range The scale becomes active again when that range is exceeded The held weight is stored in a non volatile memory for later recall if required Display turns off after 60 seconds of inactivity to conserve battery life Recall of the last held weight is available via a touchpad on the front of the case This allows a reading of the last patient s weight after the patient has been removed from the scale Battery change is made easy with external access to the battery holder MAINTENANCE INSPECTION AND TEST Joerns Healthcare recommends that a thorough inspection and test of all Oxford Hoyer lifts and lifting accessories slings etc is carried out every six months Joerns Healthcare recommends maintenance inspection and certified testing is only carried out by competent and authorized service dealers Note These rec
22. the lift with the handle foot push pad provided e ALWAYS lower the patient to the lowest comfortable position before transfers e DONOT push a loaded lift at speeds which exceed a slow walking pace 3 Km hour 0 8 metres second 12 294000 10046 Rev A re Oxford Hoyer ngirs Elevate e DONOT push the lift over uneven or rough ground Particularly if loaded e DONOT attempt to push pull a loaded lift over a floor obstruction e NEVER force an operating safety control All controls are easy to use and do not require excessive force e DO NOT park a loaded lift on ANY sloping surface e DONOT use electric lifts in a shower e DONOT charge an electric lift in a bathroom or shower room e DONOT lift a patient unless you are trained and competent to do so e YOUR lift is for patient lifting DO NOT use it or allow it to be used for any other purpose e DONOT bump the lift down steps loaded or unloaded e DONOT attempt to negotiate a loaded lift on a slope which exceeds 1 12 approximately 5 degrees e DONOT attempt to negotiate a slope without a second helper being present e DONOT use in a wet or corrosive environment such as poolside locations 7 Operating Instructions OPERATING CONTROLS Detachable Emergency Stop Button Battery Pack a uv E oer CT mergency Lower Raise 1 4 Hand Control Actuator Motor Battery Indicator 13 294000 10046 Rev A Oxford Hoyer Endlich Elevat
23. y charged Place the battery on charge whenever it is not in use If it is more convenient to do so place on charge every night The charger will not allow the batteries to overcharge AWARNING NEVER run the batteries completely flat As soon as the audible warning sounds complete the lifting operation in hand and place on charge AWARNING NEVER store the power pack for long periods without regular charging throughout the storage period AWARNING Do not charge an electric lift in a bathroom or shower room AWARNING DO NOT leave charger switched on with battery disconnected 17 294000 10046 Rev A Oxford Hoyer olie Elevate ngris 18 9 Digital Weigh Scale Optional The Oxford Hoyer Elevate as the option of an integrated digital weigh scale ABOUT YOUR SCALE The Oxford Hoyer Digital Scale is a technologically advanced microprocessor controlled digital weighing device It features a large easy to read Liquid Crystal Display LCD that shows the patient s weight The controls are simple and straightforward to use The Oxford Hoyer Digital Scale is powered by a 9 volt disposable battery which will provide approx 3000 weighing operations before replacement will be necessary The Oxford Hoyer Digital Scale is suitable for the following CATEGORIES of lift Category A Wheelchair Category D Toilet Shower Chair The Oxford Hoyer Digital Scale is suitable for patients in the SITTING po