Home

User Manual - Austin Hughes

image

Contents

1. TM Cybe rView dedicated KVM switch and rackmount screen technology User Manual IP S101 Combo KVM Extender m CyberView IP KVM EXTENDER IP S101 REACH 751 Designed and manufactured by Austin Hughes UM CV 751 IP S101 Q315V3 www austin hughes com Legal Information First English printing October 2002 Information in this document has been carefully checked for accuracy however no guarantee is given to the correctness of the contents The information in this document is subject to change without notice We are not liable for any injury or loss that results from the use of this equipment Safety Instructions Please read all of these instructions carefully before you use the device Save this manual for future reference m Unplug equipment before cleaning Don t use liquid or spray detergent use a moist cloth E Keep equipment away from excessive humidity and heat Preferably keep it in an air conditioned environment with temperatures not exceeding 40 Celsius 104 Fahrenheit m When installing place the equipment on a sturdy level surface to prevent it from accidentally falling and causing damage to other equipment or injury to persons nearby m When the equipment is in an open position do not cover block or in any way obstruct the gap between it and the power supply Proper air convection is necessary to keep it from overheating E Arrange the equipment s power cord in such a way that others won t t
2. www austin hughes com Contents lt Part 1 gt IP S101 1 1 Package Contents P 1 1 2 Specification P 2 lt Part 2 gt Application 2 1 Connection to KVM console port over IP Pa 2 2 Connection to computer over IP P 4 lt Part 3 gt IP Initial Setup P 5 7 Before Installation m Itis very important to mount the equipment in a suitable cabinet or on a stable surface m Make sure the place has a good ventilation is out of direct sunlight away from sources of excessive dust dirt heat water moisture and vibration Unpacking The equipment comes with the standard parts shown in package content Check and make sure they are included and in good condition If anything is missing or damaged contact the supplier immediately lt Part 1 gt IP S101 lt 1 1 gt Package Contents IP S101 unit X 1 CE 6 6ft Combo KVM cable X 1 Power adapter w power cord for receiver X 1 UM CV 751 IP S101 Q315V3 P 1 www austin hughes com lt 1 2 gt Specification USB Mouse KB VGA Virtual KVM PC Media Serial LAN Front PS 2 Power Mouse KB rer 100 IP S101 Specification IP Connection Console connection PC connection Virtual Media Serial Power Operation Temperature Storage Temperature Humidity Dimension Weight Environmental UM CV 751 IP S101 Q315V3 1 x RJ 45 Ethernet 10 100 1 XDB 15 VGA up to 1600 x 1200 2 x USB type connector f
3. eyboard keeps repeating keys when it is plugged into the KVM Please follow either one below a Enable key release timeout if you experience duplicated keystrokes during poor network performance login to IP KVM remote console goto Interfaces KVM settings gt Keyboard Mouse click the Key Release Timeout adjust Timeout after if necessary b Reduce video bandwidth usage if you experience duplicated keystrokes during poor network login to IP KVM remote console goto Interfaces KVM Settings gt User Console gt Transmission Encoding select Manually adjust Compression to O none and Color depth to 8 bit 256 col UM CV 751 IP S101 Q315V3 P 6 www austin hughes com Important Preconfiguration for IP console IP S101 2 REMOTE CLIENT COMPUTER SETUP The remote client computer must have a web browser such as Microsoft Internet Explorer Mozilla Firefox and Netscape Navigator and a Java Virtual Machine version 1 4 or higher installed Enable Java on the web browser A JAVA Security Issue Due to the changes from Java security customer may facing the JAVA Block message while accessing the remote console over IP Application Blocked by Java Security el For security applications must now meet the requirements for the High or Very High security settings or be part of the Exception Site List to be allowed to run More Information Reason Your security settings have blocked a self sig
4. he sites listed below will be allowed to run after the appropriate security i Do you want to run this application Publisher UNKNOWN Location httio 192 168 1 22 Running this application may be a security risk Riske ci a te men Di your computer and information at personal risk The information provided is unreliable or unknown sa it is recommended not to run this applica ton unless you are famikar with its source More Information Select the box below then click Rum to start the application EINEN mm Prompts hito 192 168 1 22 UM CV 751 IP S101 Q315V3 P 7 www austin hughes com The company reserves the right to modify product specifications without prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners Copyright 2015 Austin Hughes Electronics Ltd All rights reserved UM CV 751 IP S101 Q315V3 www austin hughes com
5. ice setup as below Device Setup Device Network Configuration Device MAC address C8 EE 08 00 00 7E x IP auto configuration None Refresh Devices IP address 192 168 1 22 Device Type Subnet mask 295 255 255 0 C Enable WLAN Configuration WLAN Devices only Gateway 0 0 0 0 Authentication Wireless LAN Configuration Super user login eless LAN ESSIT Super user password IL Enable WEP encryption New super user password ireless LAN WEP Key New password confirm Status Ready 3 Click Refresh Device to search the connected IP KVM Extender 4 Select the M A C address which you want to setup then click Query Device 5 Enter Super user login The default is super 6 Enter Super user password The default is pass 7 Enter the new super user password 8 Re enter the new password 9 Change the desired IP address Subnet mask Gateway then click Setup Device to confirm the setting to IP KVM Extender 10 The default address is http 192 168 1 22 1 Open Internet Explorer I E version 6 0 or above Authenticate Username and Password 12 Enter the IP KVM Extender address into the address bar For Single IP http 192 168 1 22 Username 13 Enter username default is super Password Password default is pass 14 After successful login to IP KVM Extender the user will enter the main page of IP KVM Extender A The setting is en
6. ned application from running If it said so here is the workaround solution Customer can use the Exception Site list feature to run the applications blocked by security setting Adding the URL of the blocked application to the Exception Site list allows it to run with some warnings Steps to Add URLs to the Exception Site list m Go to the Java Control Panel On Windows Click Start and then Configure Java Click on the Security tab Click on the Edit Site List button Click Add in the Exception Site List window Click in the empty field under the Location field to enter the URL URL should begin with http or https General Update Java Securty Advanced Appicabors leunched from the sites isted below mil be alowed to run after the appropriate secunty prompts W Enable Java content in the browser Een Y 3 192 163 1 22 Security level for applicators not on the Excepton Site list Very High Only Java applications identified by a certificate from a trusted authority are allowed to run and only if the certificate can be verified as not revoked be FILE and HTTP protocals are considered e security risk We recommend using HTTPS sites where available High Java applications identified by a certificate from a trusted authority are alowed to run even if the revocation status of the certificate cannot be verified ox ums Exception Site List Applications launched from t
7. or keyboard amp mouse 2 x PS 2 mini Din 6 pin for keyboard amp mouse 1 x DB 15 combo KVM port USB type B receptacle 1 x DB9 male 12V power adapter 0 55 C 5 60 C 0 80 Non Condensing 203 5W x 113 3D x 27 3H mm 1 7 kg 3 74 lb RoHS2 amp REACH compliant IP S101 P 2 www austin hughes com lt Part 2 gt Application IP S101 lt 2 1 gt Connection to KVM console port over IP B Consol percal KVM switch TTY BR CE 6 combo CAT 5 6 cable max 100m Network device lt gt hub or router NIS YA UM CV 751 IP S101 Q315V3 P 3 www austin hughes com lt 2 2 gt Connection to computer over IP IP S101 Computer me HE CE 6 combo KVM cable CAT 5 6 cable max 100m Network device hub or router UM CV 751 IP S101 Q315V3 P 4 www austin hughes com lt Part 3 gt IP Initial setup IP S101 After the cable connection please take the following steps to configure the IP KVM Extender 1 Download IPKVMsetup exe from the link www austin hughes com support utilities cyberview IPKVMsetup exe 2 Double click IPKVMsetup exe to configure the IP KVM Extender by dev
8. ough for intranet If the users access KVM GUI via internet please ask MIS for assistance and download IP KVM user manual from the link www austin hughes com support usermanual cyberview UM CV IP pdf UM CV 751 IP S101 Q315V3 P S www austin hughes com Important Preconfiguration for IP console IP S101 A You must complete the following tasks after the IP console setting is performed 1 TARGET SERVER SETUP Servers connected to KVM Resolution The IP KVM remote console recognizes several varieties of video display formats with resolutions up to 1600 x 1200 60Hz Refer to the User Manual for a list of supported video formats Minimize bandwidth by setting the target server s video resolution to the minimum setting required for your remote monitoring application The following video modes are recommended i 800 x 600 60Hz ii 1024 x 768 60Hz ii 1280 x 1024 60Hz On a Windows target server system select Control Panel gt Display gt Settings Modify the screen resolution value as necessary Mouse Use generic mouse drivers for optimum mouse control during remote sessions Set the mouse pointer speed to a middle setting with no acceleration or snap to effects On a Windows target server system select Control Panel gt Mouse gt Pointer Options Set the pointer speed to medium and disable Enhanced pointer precision For Linux GUls set the mouse acceleration to exactly 1 and the threshold to exactly 1 A If your k
9. rip or fall over it E If you are using a power cord that didn t ship with the equipment ensure that it is rated for the voltage and current labeled on the equipment s electrical ratings label The voltage rating on the cord should be higher than the one listed on the equipment s ratings label m Observe all precautions and warnings attached to the equipment m If you don t intend on using the equipment for a long time disconnect it from the power outlet to prevent being damaged by transient over voltage E Keep all liquids away from the equipment to minimize the risk of accidental spillage Liquid spilled on to the power supply or on other hardware may cause damage fire or electrical shock m Only qualified service personnel should open the chassis Opening it yourself could damage the equipment and invalidate its warranty E If any part of the equipment becomes damaged or stops functioning have it checked by qualified service personnel What the warranty does not cover m Any product on which the serial number has been defaced modified or removed m Damage deterioration or malfunction resulting from O Accident misuse neglect fire water lightning or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product Repair or attempted repair by anyone not authorized by us Any damage of the product due to shipment Removal or installation of the product Causes external to
10. the product such as electric power fluctuation or failure Use of supplies or parts not meeting our specifications Normal wear and tear Any other causes which does not relate to a product defect mM Removal installation and set up service charges OOOOO00O Regulatory Notices Federal Communications Commission FCC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation Any changes or modifications made to this equipment may void the user s authority to operate this equipment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures m Re position or relocate the receiving antenna E Increase the separation between the equipment and receiver m Connect the equipment into an outlet on a circuit different from that to which the receiver is connected UM CV 751 IP S101 Q315V3