1. air hose must be inspected on every occasion before use to ensure that no damage of any kind is evident e g chemical damage splits or broken stitching which could cause leakage or reduced levels of protection A monthly inspection of the apparatus is a mandatory requirement in the UK under COSHH regulations and inspection on a monthly basis is strongly recommended for all other countries Protection will only be obtained if the unit is fitted correctly Protection levels may be reduced if wind speed exceeds 2 metres per second In the unlikely event that T POWER or the T A LINE air supply fails while in a hazardous area a depletion of oxygen and increase in carbon dioxide will occur within the hood THE HELMET HOOD MUST BE REMOVED AS SOON AS POSSIBLE TO AVOID DANGER OF SUFFOCATION LEAVE THE AREA IMMEDIATELY TORNADO head tops can be used in certain explosive and flammable atmospheres when used with T IPOWER which is marked as intrinsically safe It is the employer s responsibility to ensure that the intrinsic safety approval is compatible with the particular environment At very high work rates pressure in the device may become negative at peak inhalation flow Filters must not be fitted directly to the helmet hood TORNADO T9 SPECIFICATION Description Full Hood Classification when used with TIPOWER EN 12941 TH3 TIA LINE EN 1835 LDH3 Minimum Design Flow Rate 140 L min Assigned Nominal Protectio
2. the Exhale Valve 1 Pull the valve cover from the valve and pull the exhale valve flap from its housing 2 Fit the replacement valve and check that the valve flap lies flat on the frame Align the valve cover with the slots in the valve and snap it onto the valve TORNADO T9 WARRANTY The products manufactured at our factories in Skelmersdale and Vaasa carry a warranty of 12 months unless stated otherwise for parts labour and return to site The warranty period runs from the date of purchase by the end user These products are warranted to be free from defects in materials and workmanship at the time of delivery SCOTT will be under no liability for any defect arising from wilful damage negligence abnormal working conditions failure to follow the original manufacturer s instructions misuse or unauthorised alteration or repair Evidence of purchase date will need to be provided for any claims arising during the warranty period All warranty claims must be directed through SCOTT Customer Services and in accordance with our sales return procedure NOTIFIED BODIES Inspec International Limited 0194 56 Leslie Hough Way Salford Greater Manchester M6 6AJ England BSI Product Services 0086 Kitemark House Maylands Avenue Hemel Hempstead HP2 4SQ England
3. A A A A A A A A A A A A A A A TORNADO T9 Operating and Maintenance Instructions WARNINGS Before using this equipment read the contents of EN 529 2005 and familiarise yourself with the requirements for respiratory protective devices and their potential effects on the wearer TORNADO system users must be familiar with workplace hazards prior to using the equipment and must be fully trained in the use of the apparatus TORNADO head tops must be used with a T POWER blower or T A LINE Read this Manual and the T A LINE or T POWER and T FILTER User Manuals prior to using the equipment T POWER must be fitted with filters selected from the TORNADO range of filters which are appropriate for the workplace hazard This product must only be used with Protector branded filters manufactured by Scott Health and Safety Limited The use of any other filters will negate the approval and will be likely to reduce the level of protection provided DO NOT confuse the EN 12941 and EN 12942 TORNADO filter markings with filter markings relating to other EN standards DO NOT use T9 in confined spaces oxygen deficient atmospheres lt 19 5 oxygen enriched atmospheres gt 23 or where there is an immediate hazard to life or health DO NOT use if the ambient temperature is outside of the range 10 C to 50 C Humidity levels up to 95 RH do not present any operational problems DO NOT use if the apparatus is damaged The head top and
4. an 65 RH MAINTENANCE Carry out a thorough inspection of all component parts before and after each occasion of use paying particular attention to the exhale valve flap The valve flap must be replaced annually regardless of condition Valve flaps in storage have a shelf life of five years after which time they should be discarded Exhalation valve flaps are marked with a code indicating the year of manufacture The code 07 corresponds to 2007 and a dot is added each year thereafter so 07 would equate to 2008 TORNADO T9 RECORD INSPECTION AND MAINTENANCE DETAILS Record test and maintenance details on the Inspection and Maintenance Record Sheet provided at the back of this Manual Information recorded usually includes Name of employer responsible for the apparatus Make model number or identification mark of the apparatus together with a description of any distinguishing features sufficient to enable clear identification Date of the inspection maintenance together with the name signature or unique authentication mark of the examiner Condition of the apparatus details of any defects found and any remedial action taken TORNADO T9 SPARE PARTS TA2134 Item No Description Complete Hood amp Hose Assembly T9 Exhale Valve Flap Pack of 2 TORIVALVE Exhale Valve Cover Pack of 5 2017146 FITTING SPARES To Replace
5. g Pass the free ends of the white plastic tape through the holes at the front of the outer head piece and tie in a bow across your chest Do not over tighten the bow 5 Please refer to the T POWER or T A LINE User Manual for further information AFTER USE WARNING DO NOT remove the face piece until safely clear of the hazardous area In applications where this equipment is exposed to or in contact with a hazardous material national or local regulations specific to that material must be followed when decontaminating the equipment before cleaning and maintaining it 1 Taking care not to scratch or crease the transparent areas of the head piece sponge the inner and outer surfaces of the head piece Disinfect with TriGene solution if required CAUTION DO NOT use solvent or detergent cleaners as they may cause damage DO NOT allow water to enter the breathing hose 2 Check the head piece exhale valve draw string and straps for wear and damage If the head piece is torn or it is difficult to see through the transparent areas the head piece must be discarded 3 Ensure that the head piece is thoroughly dry prior to storing 4 Hang the head piece by its top loop off the floor so that it is not creased or scratched STORAGE When not in use the equipment should be stored in a clean dry environment away from direct heat sources between 10 C and 30 C at a humidity of less th
6. n Factor when used with T IPOWER 40 500 TIA LINE 40 200 Operating Temperature Limits 10 C to 50 C Material PVC Weight According to EN 529 2005 MARKINGS AND MEANINGS The T9 head top markings are in conformance with EN 12941 as follows Marking Meaning Manufacturer Scott Health amp Safety T9 Product name CE CE mark 0086 Certifying body EN12941 Standard powered respirator EN1835 Standard air supplied TH3 Class designation EN 12941 LDH3 Class designation EN 1835 WEARING CAUTION Whilst the materials which may come into contact with the wearer s skin are not known to be likely to cause skin irritation or other adverse effects to health they may cause allergic reactions in particularly susceptible individuals 1 Loosen the draw string at the neck of the inner skirt and check that each white plastic tape passes through one of the holes in rear of the outer skirt then through the loop at the end of each the tape 2 Insert head into the head piece with the air hose positioned at the back of the head so that it trails freely down the back and is not kinked 3 Hold the draw string rubber toggle and pull both ends of the draw string to give a snug comfortable fit around the neck 1000 Grams 4 Arrange the head piece inner skirt under your outer clothing e g overall jacket or sweater with the outer skirt over your outer clothin