Home

User Manual - ICP DAS USA`s I

image

Contents

1. Each time you finish editing a Rule will go back to the Rules Setting main page All statements of edited Rules will be displayed Rules Setting main page is shown as below yey Web Inside Smart Engine 1 Basic Setting 2 Advanced Setting 3 Rules Setting yj ts Web Anywhere Automation Anywhere Channel Status Upload from Module Download to Module Rule Overview Rule Manager copy Reset Rule1 Enable Reorder swap reg Reorder lt IF gt Internal Register 1 123 AND Enable No Edit Status Internal Register 1 1 7016 1 AIO AND Rule OK Internal Register 1 Internal Register 1 lt THEN gt Internal Register 1 123 One Time Internal Register 1 1 7016 1 AIO One Time Internal Register 1 7016 1 AOO One Time lt ELSE gt Internal Register 1 Internal Register 1 One Time Rule2 OK S Rule3 S Rule4 S Rule5 S Rule6 S Rule2 Enable Description lt IF gt Timer 1 Not Timeout AND Timer 1 Timeout lt THEN gt Timer 1 Reset One Time Timer 1 Start One Time Rule7 S a Rules S Rule9 S Rule10 S Rule11 S Rule12 Rule13 Rule3 Enable Rule14 Description lt IF gt Tate Edit Schedule 1 Out of Range AND Schedule 1 In Range lt THEN gt Schedule 1 Disable One Time S
2. Power On Value OFF M oC Enable Pulse Output o P T a Pulse High 10ms Pulse Low 10ms Channel Power On Value Enable Pulse Output F Pulse High 10ms Pulse Low 10ms Figure 4 8 XW Board DO attribute setting page The settings are as follow Nickname for you to define nicknames for each I O channel this nickname will be displayed on the Channel Status page You can specify the initial status to be ON or to be OFF when the WISE 580x is power on Select the value from the dropdown list of Power On Value field The default value is OFF If you check the Enable pulse output checkbox it will allow this DO channel to perform pulse output and form a periodic pulse cycle In Pulse Output mode the selected DO channel will generate a square wave according to specified parameters Pulse High and Pulse Low Pulse High and Pulse Low are required and has to be entered in multiples of 10ms Pulse High indicates the ON time duration and Pulse Low indicates the OFF time duration in a periodic Pulse cycle After all DO channel settings are completed click Save button to save the changes Pleas
3. 11 111 1V In the Sync Interval field select the time interval to specify how often will the WISE 580x automatically connect to SNTP time server for time synchronization through the network If you select disable it means the time synchronization function will not be performed In the SNTP Time Server field input the IP address or domain name of the SNTP Time Server Please refer to the link time windows com this is a standard SNTP server from Microsoft for Windows operating system to synchronize the system time In the Port field input the port number which the SNTP time server open for connection the default port number will be 123 In the Time Zone field select the time zone from the dropdown list http wise icpdas com 25 ICP DAS WISE User Manual After all settings are completed click Save button to save the changes And please remember all settings will take effect only when they have been downloaded to modules if you close the Web page before finishing Download to Module all settings will be disappeared as well 4 3 Communication Setting Communication Setting allows you to make a change to network configuration web server port or Modbus settings on the controller The following figure illustrates the configuration interface Gateway Enable Modbus RTU Slave from COM1 Figure 4 4 Communication setting page Each time when you enter this p
4. Upload from Module to start the upload process When the upload process is finished the window showing progress status will notify you the process is completed The uploading process is completed Figure 8 1 Message showing a successful upload Click close to close the upload process window to finish upload Now the rules have been uploaded from hardware devices to the web page you can modify and download the edited rules to the hardware devices later again http wise icpdas com 106 ICP DAS WISE User Manual 9 Channel Status Channel Status function offers an easy to view monitoring page that allows you to view important controller information in real time without SCADA software The Channel Status page is shown as below Channel Status Page Le DI Channel DO Channel Figure 9 1 Channel Status page On the Channel Status page select the I O module that is connected to the WISE 580x the I O channel values of XW Board I 7000 module Modbus RTU Slave module and the Internal Register will be displayed If you give nicknames to the I O channels or Internal Registers the nicknames will be shown on this page as well You can modify the values of the DO channels for the I O modules by clicking on the value buttons or input a new AO channel value on this page This page will be updated once every 10 seconds showing the latest data of the controllers http wise icpdas com
5. WISE Firmware Uploader Installer built on 2011 12 16 at PF 02 44 49 lt Back Mext gt Figure 10 3 Display installation progress http wise icpdas com 109 ICP DAS WISE User Manual When the installation is completed click Finish to close the process 6 WISE Finmware Uploader version 2 2 Setup Completing the WISE Firmware Uploader version 2 2 Setup Wizard WISE Firmware Uploader version 2 2 has been installed on your computer Click Finish to close this wizard Figure 10 4 Complete the installation 10 2 2 Uninstall WISE Firmware Uploader Follow the steps below to uninstall WISE Firmware Uploader Click Start gt All Programs gt ICPDAS WISE and then click Uninstall under the WISE category ox oe bs contro rane ae eee A Paint a Accessories gt as Startup gt E2view E2view amp Internet Explorer FA PIso ps4o0 All Programs fem ICPDAS Log OFF Lo Til A PIso ps4o00 EN ET M8194H fam WISE Fiomware Uploader Br WISE Firmware Uploa Figure 10 5 Start to uninstall WISE Firmware Uploader You will see a window pop up as below click Next to continue BEE WISE Firmware Uploader Uninstall Welcome to the WISE Firmware Uploader version 2 2 Uninstall This wizard will guide you through the uninstallation of WISE Firmware Uploader version 2 2 Before starting the uninstallation make sure WISE Firmware Uploader versio
6. 0x EEEE 781 Number After all Discrete Input settings of the Modbus RTU Slave module are completed click Save button to save the changes http wise icpdas com 47 ICP DAS WISE User Manual 4 7 3 Modbus RTU Slave Module Input Register Setting The Modbus RTU Slave module Input Register Setting page is shown as follow Modbus RTU Module Setting Polling Timeout 30 milliseconds Timeout Retry Interval 5 seconds Data Model Input Register 3x Start Address Continuous Data Number Data Type 16 bit Signed Integer Figure 4 26 Modbus RTU Slave Module Input Register Setting Page The detailed information of the parameters are as follow http wise icpdas com Please refer to section 4 7 for detailed information of the Address Name Polling Timeout and Timeout Retry Interval fields Data Model WISE 580x offers 4 Data Model selections to match the Modbus RTU Slave module configuration Please refer to the section 4 7 1 for detailed information In this case please select Input Register 3x Start Address Allows to set up the starting address of Input Register 3x on the Modbus RTU Slave module you would like to retrieve Continuous Data Number After finishing the Start Address setting specify the Continuous Data Number it is the number of Input Register data you would like to retrieve from the Start Address Data Type WISE 580x support 6 kinds of data type setti
7. field When the Rule status matches the specified status the evaluation result will be true ii Click Save button to save the settings The Rule Status Condition Setting page will be closed and return to the Rule setting page 6 1 12 SMS Command The SMS Command variable status can included in IF Condition as part of logic rules It allows to modify the SMS Command variable status for remote control The setting page is shown as below SMS Command Condition Setting Figure 6 15 SMS Command setting page Please follow the steps below i In the Index field specify the SMS command variable index number you want to use in IF condition from the dropdown list ii In the Value field set the SMS command variable status to be 0 or 1 Once when the variable matches this pre set status value the evaluation result will be TRUE The default pre set status value is http wise icpdas com g7 ICP DAS WISE User Manual 0 Click Save button to save the settings The popup window will be closed and will return to the rule setting page http wise icpdas com g8 ICP DAS WISE User Manual 6 2 THEN ELSE Action In the THEN ELSE Action statement the following values or status can be included AO DO DI Counter Coil Output Holding Register Internal Register Timer Schedule Email CGI Recipe Rule Status Data Logger SMS Alarm Apply to WISE 5801 only 06004000
8. wise icpdas com 123 ICP DAS WISE User Manual By Channel AI Ch 1 30142 N 2 Float l Type Setting By Channel AI Ch 2 30144 N 2 Float l Type Setting By Channel AI Ch 3 30146 N 2 Float Type Setting By Channel AI Ch 4 30148 N 2 Float Type Setting By Channel AI Ch 5 30150 N 2 Float Type Setting By Channel AI Ch 6 30152 N 2 Float Type Setting By Channel AI Ch 7 30154 N 2 Float Type Setting Please note for different modules of I 7017 and I 7018 the numbers of channel might be different the address of each channel will follow in sequences By Channel 40140 N 2 Float Type Setting 11 7022 2 AO channel 1I 7021 1 AO channel Holding Register Unit Register 16 Bits By Channel AO Ch 0 40140 N 2 Float Type Setting By Channel AO Ch 1 40142 N 2 Float Type Setting http wise icpdas com 124 ICP DAS WISE User Manual D I 7024 4 AO channel co tete Float Type Setting oat By Channel Float Type Setting oat By Channel Float Type Setting By Channel Float Type Setting iscrete Inputs Unit Discrete Input 8 Bits DI Ch 0 DI Ch 1 DI Ch 2 DI Ch 3 DI Ch 4 10144 N 1 Byte Byte Byte Byte Byte O OFF 1 ON O OFF 1 ON O OFF 1 ON O OFF 1 ON O OFF 1 ON Input Register Unit Register 16 Bits DI Counter 0 30140 N DI Counter 1 30141 N DI Counter 2 30142 N DI Counter 3 DI Counter 4 1 1 1 30143 N 1 30
9. Click Firmware File button browse the file through the File Dialog Box to select the appropriate WISE firmware version as shown in the following figure WISE Firmware Uploader version 2 2 Module Type WiISE 580x de IP Address 192 168 100 212 Upload Firmware Select a HEX file Look in ICPDAS O eea 5 My Recent Documents O sktop gt My Network Files of type Hex Files hex v Figure 10 12 Select the WISE firmware vi Upload WISE firmware program Click Upload Firmware button to start update WISE firmware to the WISE module WISE Firmware Uploader version 2 2 Module Type WISE 580h 4 IP Address 197 168 100272 DAICPDASWISE 5801v220 HEX Upload Firmware About WISE Figure 10 13 Upload firmware http wise icpdas com 113 ICP DAS WISE User Manual The status of WISE firmware update progress will be shown as below Package Installation Status Installing File Jc t ao htm Figure 10 14 Display firmware update progress 1 When the following figure is displayed please wait for about 10 Secs the WISE module is arranging the firmware files Please note this message will be displayed 4 times during the update process Package Installation Status Installing File Pd Figure 10 15 Display firmware update progress 2 When the update of WISE firmware is completed a pop up window will appear to inform you
10. L 2m o o a Figure 4 19 1 7000 module AO attribute setting page The settings are as follow Polling Timeout The time for WISE 580x to send command to the I 7000 module and wait for the response the unit will be ms Nickname For you to define nicknames for each I O channel this nickname will be displayed on the Channel Status page Type Select the appropriate AO signal output type After all AO channel settings are completed click Save button to save the changes Please note please use DCON Utility to set up the Power On Value for each AO channel on I 7000 modules 4 7 Modbus RTU Modules Setting In addition to XW Board and I 7000 I O modules WISE 580x also allows to connect with devices that support Modbus RTU Slave protocol for I O control Through Modbus RTU protocol it enables to read back 4 types of Modbus data Coil Output Discrete Input Input Register and Holding Register from the Modbus RTU Slave modules to the WISE 580x And by WISE IF THEN ELSE rule engine it allows to perform automation control Operation on the devices And with SCADA software it also allows to monitor and control the Modbus RTU device retrieved information on the WISE 580x http wise icpdas com 39 ICP DAS WISE User Manual In Modbus RTU Modules Setting page it allows to perform parameters settings and related con
11. Start the DCON Utility and verify if the COM Port value is accurate Pam Select the COM Port and Baud Rate EJ DCON UTILITY ER519 select CO File COM Pot Search Run Terminal Len COM to search Time Out Setting COM 200 ME Baud Rate Option 4608 r 220 115200 M 57600 36400 f 19200 9600 M 4800 M 2400 M 1200 Select All Clear All PDSSPPDS 700 Protocol Option i OCON Modbus ATU Modbus ASCII Checksum Option W Disable Enable Panty Option Iw None N 8 1 Even E 6 1 home M82 F Odd 0 8 1 Industry Computer AS 485 Port Option ATS_CONTROL_TOGGLE Se RTS for Vision Box Cancel Figure 2 6 Check COM port Baudrate and DCON Protocol settings 111 Perform Search to find all I 7000 modules that are connected to the PC Fd DCON_UTILITY ER519 select COM Port File COM Port Search Eun Terminal Language adamm 2 ml E module Address Eaudrate Checksum DCON_UTILITY_ ER 520 beta 4 The Found Out I 7000 8009 module m i File COM Port Search Run Terminal Language Help ean CE A tat 0 End 16 Address 0255 Description module Address Baudrate Checksum format Status Description 024 1 1 115200 Disable NE 4 40 m VIIDCON 7065D 2 2 115200 Disable N8 1 4 Dl 5 DO DCON 70172 104 115200 Disable N81 10 20 Allm my VIDifferential Single Ended D CON Figure 2 7 l 7000 module Searc
12. 10mA plus the Deadband value 2mA as shown in following figure IF Al lt 10mA THEN DO ON ELSE DO OFF 12mA 10mA DO OFF lt DO OFF lt DO ON Figure 4 11 Al Deadband Operation lt or lt a numerical value c In the IF Condition when AI a numerical value Assuming the Deadband value is set to be mA and the following statements are defined in the related logic Rule IF AIO 9mA THEN DO ON ELSE DO OFF that means when AIO receives a signal between 8mA 9mA minus the deadband value ImA and 10mA 9mA plus the deadband value ImA the DO channel will change to ON immediately However when the AIO channel value http wise icpdas com 32 ICP DAS WISE User Manual exceed 10mA or is lower than 8mA the DO channel will change to OFF as shown in following figure IF Al 9mA THEN DO ON ELSE DO OFF 10mA 9mA 8mA lt DO OFF DO DO OFF DO ON lt DO OFF Figure 4 12 AI Deadband Operation a numerical value After all AI channel settings are completed click Save button to save the changes 4 5 4 XW Board AO Channel Settings The XW Board AO Channel Setting page is shown as follow using XW304 as an example ooe Remove Power On Value O 5 Min 5 My Figure 4 13 XW Board AO attribute setting page The settings are as follow Nickname For you to define nicknames for each I O channel this nickname wil
13. 11 Set up the expression statement for this channel value Select an ee 99 99 99 99 299 99 operator from gt lt lt gt or lt ii And then ns the evaluation value If this Holding Register value match the evaluation criteria the result of this condition evaluation will be true iv Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 1 8 Internal Register Internal Register value can be used as evaluation criteria for IF condition statement the editing page for Internal Register Condition Setting is shown as follow _ Save Figure 6 11 Internal register condition setting page Follow the following steps 1 Select the Internal Register that you are going to use the value as evaluation criteria for IF condition statement Specify the Internal Register Index from the dropdown list of Index field 11 Set up the expression statement for this Internal Register value co 99 99S 99 99 299 99 99 Select an operator from gt lt lt gt or lt and then specify the evaluation value li this Internal Register value match the evaluation criteria the result of this condition evaluation will be true You can compare the Internal Register value with the following 3 values for condition evaluation Self Defined value Giving a self defined value to compare with the Internal Register value
14. 11 There are two data arrangement types for the I O Data Table Coil and Register and Register Merge Coil into Register In the Coil and Register type The I O module s DI DO Modbus Coil data will be saved in the Coil area of the I O Data Table and the I O module s AI AO Modbus Register Internal Register data will be saved in the Register area of the I O Data Table If you select the Register Merge Coil into Register type then the I O module s DI DO Modbus Coil data will be saved in the Register area of the I O Data Table in binary format Each Register can store http wise icpdas com 67 ICP DAS WISE User Manual 111 Address es om O 2 AI0 en Pee 2 AI2 G o S O O a OOS 16 Coils data The Module field allows to select specific I O module or Internal Register that will be used in the I O Data Table select the Channel and Index number from the drop down lists to edit the table configuration of the I O module s channel 1 0 Data Table Configuration Coil and Register 7 Register Merge Coil into Register SE SC O Receiver Start Address Receiver Start Address Figure 5 13 The I O Data Table for Coil and Register type When you complete the setting of Module Channel and Index please click the Add button to add the channel of the I O module into the I O Data Table You can use
15. 7000 module with RS 485 Address 2 is 2 1 40 40 the N value of I 7000 module with RS 485 Address 3 is 3 1 40 O and the N value of I 7000 module with RS 485 Address 16 is 16 1 40 600 The I 7000 module Modbus Address Table is shown as below 7011 1 7012 I 7014 1 DI 2 DO 1 AI channel Coils Output Unit Coil 8 Bits DO Ch 0 00140 N 0 OFF 1 ON DO Ch 1 00141 N 0 OFF 1 ON http wise icpdas com 122 ICP DAS WISE User Manual Discrete Input Unit Discrete Input 8 Bits Input Register Unit Register 16 Bits By Channel AI Ch 0 30140 N 2 Float Type Setting DI Counter 0 30142 N 0 65535 I 7013 1 DI channel Discrete Input Unit Discrete Input 8 Bits DI Ch 0 10140 N 0 OFF 1 ON Input Register Unit Register 16 Bits DI Counter 0 30140 N Int 0 65535 I 7015 6 AI channel A Ae a A S ore LUT A j UC BS JIT Input Register Unit Register 16 Bits By Channel AI Ch 0 30140 N 2 Float l Type Setting By Channel AI Ch 1 30142 N 2 Float l Type Setting By Channel AI Ch 2 30144 N 2 Float l Type Setting By Channel AI Ch 3 30146 N 2 Float Type Setting By Channel AI Ch 4 30148 N 2 Float Type Setting By Channel AI Ch 5 30150 N 2 Float Type Setting I 7005 I 7017 I 7018 I 7019 8 AI channel 11 27 JUL ae Input Register Unit Register 16 Bits By Channel AI Ch 0 30140 N 2 Float Type Setting http
16. Close the window to finish firmware upload Information I Firmware Upload Successful Figure 10 16 Complete firmware update vil Module reboot automatically After complete the firmware update process WISE module will automatically reboot The new updated firmware will take effect after the reboot http wise icpdas com 114 ICP DAS WISE User Manual Appendix I Modbus Address Table WISE allows you to retrieve data on hardware devices via Modbus TCP RTU protocol WISE 580x register addresses are specified according to Modbus register mapping tables more detailed information will follow Please Note The addresses are in Base 0 format The addresses are in Decimal format The default value of NetID is 1 and you can modify the NetID value in the Ethernet Setting page Please refer to 4 3 Ethernet Setting If the data is displayed in Floating format or 32 bits AI channel value AO channel value or Internal Register Input Register and Holding Register etc each record of data will take two registers to hold the data The following code example demonstrates how to join the two registers into one floating point value float register_to_float short rl short r2 float f int a amp f a rl a tSr return f Please note for the compilers are different big endian or little endian the floating point composing order might be different For example if rl represent the address o
17. Continuous Data Number setting click on Add button A new Discrete Input address block will be added to the Modbus address mapping table shown as below All added address blocks will be located in sequences staring from the Starting Address Please note The address number on the first column WISE 580x Local Address means the local Modbus address of WISE 580x to keep the retrieved Discrete Input data The following is an example about Discrete Input setting for a Modbus RTU Slave module The starting Modbus address of the Discrete Input block is 10020 10000 20 it requires to set 6 continuous Discrete Input data in the setting So that the WISE 580x can access the 10020 10021 10022 10023 10024 and 10025 Discrete Input address of the module and these retrieved Discrete Input data will be kept in WISE 580x Modbus Address 10780 10781 10782 10783 10784 and 10785 46 ICP DAS WISE User Manual Modbus RTU Module Setting 5 onds Data Model Discrete Input 1x paires Coil Output Discrete Input Input Register Holding Register Address a _ on Figure 4 25 Modbus RTU Slave Module Discrete Input Setting Example To modify the starting address or quantity setting please move the cursor to the setting the function buttons such as Edit or Remove will appear Click Edit or Remove for modification WISE 5800 Local Address Coil Output Discrete Input
18. DI Counter Discrete Input Coil Output Input Register Holding Register Internal Register Timer Schedule Rule Status SMS Command Apply to WISE 5801 only The AI channels DI channels Discrete Input Coil Output Input Register and Holding Register on WISE 580x will automatically appear on the list To include subjects other than I O channels in the IF Condition statement they have to be pre defined in Advanced Setting first The subjects that already being defined in Advanced Setting will appear on the dropdown list of IF Condition Select the subject you want to use and then click right side button a window will pop up for you to edit detailed information 6 1 1 Al shown as below Al Condition Setting AI channel value from XW Board or I 7000 module can be included in the IF condition statements the editing page for AI Condition Setting 1s eo Assign Value as M Figure 6 4 Al condition setting page Follow the following steps http wise icpdas com 78 ICP DAS WISE User Manual 1 Specify the module and channel from the dropdown list of the Module amp Channel section that you are going to include its value in the IF condition statements The Module amp Channel section of XW Board is shown as below use X W304 AI channel 0 as an example Module amp Channel XW304 M Channel 0 The Module amp Channel section of I 7000 is shown as below use I 7005 Add
19. Index field 11 Specify the Rule status to be Disable or Enable from the dropdown list of the Status field When the Action being executed the Rule status will be changed to specified status i Click Save button to save the settings The Rule Status Action Setting page will be closed and return to the Rule setting page 6 2 13 Data Logger You can execute One Time Log Start or Stop for one time log recording start period recording or stop period recording in the Action statements The three actions are described below One Time Log Perform data recording one time only when an THEN ELSE action event is triggered Stop Stop period recording data During the stop recording http wise icpdas com 98 ICP DAS WISE User Manual interval if the current Log file reached the Close Log File time interval and the file 1s closed the file will still be sent via FTP or Email The system will create a new Data Log file for One Time Log recording Start Start period recording data The editing page for Data Logger Action Setting is shown as below Data Logger Action Setting One Time Log Figure 6 29 Data Logger action setting page Follow the following steps i In the Action field select One Time Log Start or Stop from the drop down list ll Click Save button to save the settings The popup window will be closed and return to the Rule settings p
20. Input Input Register Holding Register Address ue 1x iii i Edit Remove M i After all Coil Output settings of the Modbus RTU Slave module are completed click Save button to save the changes 4 7 2 Modbus RTU Slave Module Discrete Input Setting The Modbus RTU Slave module Discrete Input Setting page is shown as follow Modbus RTU Module Setting Polling Timeout 300 milliseconds Timeout Retry Interval 5 seconds Data Model Discrete Input 1x M Continuous Data Number Figure 4 24 Modbus RTU Slave Module Discrete Input Setting Page The detailed information of the parameters are as follow http wise icpdas com Please refer to section 4 7 for detailed information of the Address Name Polling Timeout and Timeout Retry Interval fields Data Model WISE 580x offers 4 Data Model selections to match the Modbus RTU Slave module configuration Please refer to the section 4 7 1 for detailed information In this case please select Discrete Input 1x 45 ICP DAS WISE User Manual http wise icpdas com Start Address Allows to set up the starting address of Discrete Input 1x on the Modbus RTU Slave module you would like to retrieve Continuous Data Number After finishing the Start Address setting specify the Continuous Data Number it is the number of Discrete Input data you would like to retrieve from the Start Address After finishing the Start Address and
21. Internal Register Input a value if you want to set a default value for the Internal Register and set the nicknames for the Internal Register this nickname will be displayed on the Channel Status page After you finish all the Internal Registers selections and settings click Save button to save the settings 5 2 Timer Setting WISE provides 12 groups Timer for timing functions The Timer status can be Not Timeout or Timeout They can be included in the IF Condition statements The Timer Action can be Start or Reset The Start Action will start to run the Timer and if the Start Action is triggered one more time when the Timer is running the Timer will restart again The Reset action will reset the Timer and stop running the Timer The Timer will be in Timeout status only when the Timer is running and reached the setting time http wise icpdas com otherwise the status of Timer will remain in Not Timeout The 55 ICP DAS WISE User Manual Timer setting interface is shown as below Timer Setting Page SON Ferd Initial Status PE Figure 5 2 Timer setting page Follow the following steps Timer Amount field is required Select the total number of timer you are going to use from the dropdown list Specify the timer you want to set up by selecting its index number from the dropdow
22. Modify the value of SMS Command variable 2 to be 1 The SMS message which WISE 5801 replies GET ON 8 7 4 3 Replies real time channel data SET I 7024 2 AO Channel 1 as 2 5 Replies that the value on AO channel 1 on the I 7024 has been modified to 2 5 SMS Command 2 set as 1 Replies that the value of SMS command variable 2 has been modified to 1 In additional to edit the SMS command by command coding rules WISE 5801 also provides an user friendly interface for editing a SMS Quick command a simple self defined command string to replace the original complex SMS command applies to Firmware v2 3 or later version When WISE 5801 receives the SMS Quick Command it will automatically translate it to the SMS original command and execute the SMS command The SMS setting page is as follow http wise icpdas com 72 ICP DAS WISE User Manual SMS Setting Page cooo D E Enable WISE to accept SMS Command Authorized Phone Number Note Please input country area code and number Quick Command SMS Alarm Sending from WISE Unicode Message Note The length of the message cannot exceed 160 characters Figure 5 17 SMS Setting Page Please follow the steps below 1 In the PIN field input the 4 digit SIM card PIN code If the PIN code 1s not required leave the field blank ii Enable the Enable WISE to accept SMS Command function to sta
23. OFF I ON O OFF 1 ON O OFF 1 ON O OFF 1 ON O OFF 1 ON 0 65535 0 65535 0 65535 0 65535 0 65535 0 65535 0 65535 0 65535 0 65535 0 65535 0 65535 0 65535 0 65535 1 p lt ICP DAS WISE User Manual DI Counter 13 30033 Int 0 65535 DI Counter 14 30034 Int 0 65535 DI Counter 15 30035 Int 0 65535 3 RS 485 Module Information This block stores all module information that are connected with the WISE 580x through RS 485 COM2 Addre Input Register Unit Register 16 Bits I 7000 Module Name 30040 1 Int 7011 7088 re ame Modbus RTU Module 30056 1 Int 1 Connected 4 RS 485 Module Error Code This block stores the Error Code that is generated during the operation of modules that are connected with the WISE 580x through RS 485 The Error Code helps to quickly identify problems when experience communication difficulties H T Ai altiCLEr 1N AHC CILS UI AA a as IU Input Register Unit Register 16 Bits Error Code of I 7000 30060 0 65535 address 1 16 30075 Error Code of Modbus 30076 RTU Slave 1 Int 0 65535 30079 address 17 20 http wise icpdas com 120 ICP DAS WISE User Manual The Error Code list is as follow 9 Addr Error The 1 7000 modules definition in WISE is not the same which WISE 580x really connects with 5 Internal Register Data This block stores 48 sets of Internal Register data provided by WISE controller Parameter Name Modbus Length Data Range A
24. Schedule condition Setting is shown as follow schedule Condition Setting er Figure 6 13 Schedule condition setting page Follow the following steps i Select the schedule that you are going to use its status as evaluation criteria for IF condition statement Specify the schedule index from the dropdown list of the Index field 1 Define the evaluation criteria of the status in IF statement to be Out of Range or In Range If the status of the schedule matches the evaluation criteria the result of this condition evaluation will be true lil Click Save button to save the settings The popup window will closed and return to the rule settings page 6 1 11 Rule Status The Rule Status 1f the Rule is disabled or enabled can be used as evaluation criteria for IF condition statement Please note there must be at least one edited rule on WISE controller for setting up Rule Status in the IF Condition Setting page The editing page for Rule Status Condition Setting is shown as below http wise icpdas com 26 ICP DAS WISE User Manual Rule Status Condition Setting er 7 sats Figure 6 14 Rule Status condition setting page Follow the following steps i Specify the index number of the Rule that is going to be used in the IF Condition statement from the dropdown list of the Index field 11 Specify the Rule status to be Disable or Enable from the dropdown list of the Status
25. WISE User Manual Modbus RTU Module Setting Polling Timeout Timeout Retry Interval Data Model Start Address Continuous Data Number Data Type WISE 5800 Local Address Coil Output Ox Input Register 3x v Figure 4 27 Modbus RTU Slave Module Input Register Setting Example Please note If the Data Type is set as 16 bit HEX the retrieved HEX data from Modbus RTU Slave module would be and these transformed data can be used in IF THEN ELSE rule setting transformed to floating point automatically To modify the starting address or quantity setting please move the cursor to the setting the function buttons such as Edit or Remove will appear Click Edit or Remove for modification Coil Output 0x After all Input Register settings of the Modbus RTU Slave module WISE 5800 Local Address Discrete Input 1x Input Register Holding Register 4 780 781 782 783 32 bit Floating Point are completed click Save button to save the changes 4 7 4 Modbus RTU Slave Module Holding Register Setting The Modbus RTU Slave module Holding Register Setting page is shown as follow http wise icpdas com 50 ICP DAS WISE User Manual 300 miliseconds Start Address Data Model Holding Register 4x M Continuous Data Number Data Type 16 bit Signed Integer Figure 4 28 Modbus RTU Slave Module Holding Register Sett
26. directed to the Channel Monitoring page the Channel Monitoring page is shown as below Wy Web Inside Smart Engine ie Web Anywhere Automation Anywhere Login Password al Go to Logic Settin ICP DAS Co Ltd All Rights Reserved Figure 3 5 The Channel Monitoring page before login You can input the password to get into the Channel Monitoring page or select the Go to Logic Setting page to perform logic settings After you login into the page it will show WISE 580x module name and will list all I O devices currently connected to the WISE 580x such as the XW Board I 7000 modules and Modbus RTU modules The interface is shown as below uy _ Web Inside Smart Engine ow Web Anywhere Automation Anywhere WISE 5801 WISE Controller 1 WISE Engine Version 2 20 Internal Register XW Board XW107 G l 7000 Module Address 4 Address 5 l 7021 o l 7088 Address 16 l 7080 Modbus RTU Module Figure 3 6 The Channel Monitoring page after login http wise icpdas com 99 ICP DAS WISE User Manual If you login into the Channel Monitoring page as a Guest you can only view the channel data You will not be allowed to modify the data You are required to login as Administrator to modify the channel output data such as DO AO Internal Register Coil Output and Holding Register value The following figure shows the interface that will be displayed when login as an Adm
27. http wise icpdas com 84 ICP DAS WISE User Manual Channel value Using AI channel values from other modules XW Board or I 7000 to compare with the Internal Register value Internal Register Using another number of internal register value to compare with the Internal Register value Internal Register M i Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 1 9 Timer Timer condition can be used as evaluation criteria for IF condition statement the editing page for timer condition setting is shown as follow Timer Condition Setting Not Timeout Figure 6 12 Timer condition setting page Follow the following steps 1 Select the timer that you are going to use its status as evaluation criteria for IF condition statement Specify the timer index from the dropdown list of the Index field 1 Define the evaluation criteria of the timer status in IF statement to be Not timeout or Timeout If the timer status match the evaluation criteria the result of this condition evaluation will be http wise icpdas com g5 ICP DAS WISE User Manual true i Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 1 10 Schedule Schedule condition can be used as evaluation criteria for IF condition statement the editing page for
28. icpdas com 130 ICP DAS WISE User Manual The allocation of the Modbus Address in WISE 580x for the Discrete Input setting of this Modbus RTU module Devicel is shown as below The allocation of the Modbus Address in WISE 580x for the Input Register setting of this Modbus RTU module Devicel is shown as below The allocation of the Modbus Address in WISE 580x for the Holding Register setting of this Modbus RTU module Devicel is shown as below http wise icpdas com 131 ICP DAS WISE User Manual Appendix Il Reset to Factory Default Setting During the operation of WISE 580x if the hardware system setting data is lost or encounters any abnormal problem that you would like to reset the system to factory default please follow the steps below 1 Power off the WISE 580x make sure the Init Switch is in the OFF position Rotary Switch 2 Switch Rotary Switch to position to restore to factory default the position of Rotary Switch indicates Execute WISE 580x firmware Restore Web Page display language to factory default English Restore network settings to factory default 192 168 255 1 255 255 0 0 192 168 0 1 Connect WISE 580x to the power when the L2 green light turns to be ON it indicates that the setting is completed http wise icpdas com 132 ICP DAS WISE User Manual icr WISE 5800 1111111 DEL EL DELL EL D DL E1 Ethernet 10 100 Bas COM1 RS 232
29. page is shown as follow using XW 107 as an example http wise icpdas com 28 ICP DAS WISE User Manual XW Board Setting Page ce o Add Remove Counter Initial Value C ee CS Counter Initial Value a Figure 4 7 XW Board DI attribute setting page The settings are as follow Nickname For you to define nicknames for each I O channel this nickname will be displayed on the Channel Status page Counter Type Specify the counter type to be Falling edge detection ON to OFF or Rising edge detection OFF to ON if you select Disable indicates that the counter of this DI channel will not function Counter Initial Value You can set the initial value of the counter in the Counter Initial Value field This counter will start counting from the initial count value The default initial value is O After all DI channel settings are completed click Save button to save the changes 4 5 2 XW Board DO Channel Settings The XW Board DO Channel Setting page is shown as follow using XW 107 as an example http wise icpdas com 29 ICP DAS WISE User Manual XW Board Setting Page Remove Channel p i Ch 3
30. select the time interval to close a data log file There are eight options hour 2 hours 3 hours 4 hours 6 hours 8 hours 12 hours 24 hours For example if the Close Log File time interval is set as 3 hours and Sampling Period is set as 5 mins it means WISE 580x will record data every 5 mins And the log file is created at 0 o clock 3 o clock 6 o clock 9 o clock 12 o clock 15 o clock 18 o clock and 21 o clock When the system time reached these specified time the Data Log file will be closed automatically the time interval of this first file will be shorter than 3 hours and create a new data log file to record another 3 hours and so on Click the check box to specify the Log file to be sent by Email or FTP You can select both ways to send the Log file If no option is selected the data file will not be sent If you select the option to send file by Email select the Email index you are going to send to when the data file 1s closed The Email of http wise icpdas com 65 ICP DAS WISE User Manual this index has to be previously set and the file will be sent as an attachment Vill If you select the option to send file by FTP input the FTP Server IP address port number login ID password FTP path and Timeout information There are two options for Time to Upload you can choose to upload the file when the time of the Log file reached the Closed File time interval via FTP or up
31. the Control Panel in the right bottom of the I O Data Table to Move or Delete the channel setting of the I O Data Table The Clear All button is used to clear all channel settings in the I O Data Table Trim button is used to remove all the excess space between the channel settings to make all channel settings of the I O Data Table to be more compact In the I O Data Table the Local Address in the left side is the address for saving I O Data Table in the WISE Modbus Address Table The starting address is 1230 Base 0 amp Decimal format The maximum length is 300 Therefore SCADA software can connect to the WISE Modbus address 01230 to inquire the first Coil data in the I O Data Table and connect to the WISE Modbus address 41230 to inquire the first Register data in the I O Data Table If the http wise icpdas com 68 ICP DAS WISE User Manual Active sending of I O Data Table function is enabled the Receiver Start Address in the upper area of the I O Data Table is the address of the Receiver s SCADA software Modbus starting address The content of the I O Data Table that WISE 580x send actively to Receiver s SCADA software with Modbus TCP Slave function will be saved from the starting address The naming rule of the channel inside the I O Data Table is RS 485 Address Channel Type Channel Index For example 1 DIO is for the DIO channel of the I O module with RS 485 address 1 The fo
32. the controller via COM2 Please note to ensure a proper connection make sure when you use DCON Utility to set up the Baudrate and the checksum for each I 7000 module the Baudrate and the checksum have to be set the same as WISE 580x settings as previous setup http wise icpdas com 34 ICP DAS WISE User Manual In addition to Auto Search you can add the I 7000 module one by one complete Module Type Address and Polling Time field and then click Add button to add a new I 7000 module An example of the I 7000 module list is shown as below l 7000 Module Setting Page Baudrate COM2 115200 v pps Address ee Jofopofs 5 ose te Le oo m 2 2 Le Lo Figure 4 15 1 7000 modules list Select an I 7000 module and click on Setting button to edit detailed parameters for each module To remove the I 7000 module select the module you would like to remove and click Remove button to remove the specific module To relocate I 7000 to other address click Move Up or Move Down to move the I 7000 module to desired address After all I 7000 module settings are completed click Save button to save the changes Please refer to the following sections for more detail on I 7000 module DI DO AI and AO channel configurations Please note currently WISE 580x only connect to I 7000 via COM2 please make sure if the I 7000 modules are connected to WISE 580x CO
33. user to press the Download to Module 105 Figure 7 2 Message showing a successful download ccccccesseeeseeceeeeeeeeeeeeees 105 Figure 8 1 Message showing a successful upload 106 Fisur 91 s Chamel Status pa oie ne AS ns ane Nes te 107 Figure 10 1 Install WISE Firmware Uploader 109 Firre 1027 Select installation direcione San ue 109 Figure 10 3 Display installation progress ss 109 Figure 10 4 Complete the installation ss 110 Figure 10 5 Start to uninstall WISE Firmware Uploader cc esseeeeeeeeeeeees 110 Figure 10 6 Uninstall WISE Firmware Uploader 1 110 http wise icpdas com ICP DAS WISE User Manual Figure 10 7 Uninstall WISE Firmware Uploader 2 111 Figure 10 8 Complete uninstalling WISE Firmware Uploader 111 Figure 10 9 Launch WISE Firmware Uploader 112 Figure 10 10 Select the WISE module type ss 112 Figure TOII ASS Om IP AdSense id 113 Preure 10 12 Select the WISE Titi w ane Han ide does 113 Figure TO 18 Upload Tir W AT meet 113 Figure 10 14 Display firmware update progress 1 114 Figure 10 15 Display firmware update progress 2 114 Figure 10 16 Complete firmware update nine nain ieitaasam iene 114 http wise icpdas com g ICP DAS WISE User Manual 1 Introduction WISE 580x Web Inside Smart Engine PAC Controller is an Intelligent Data Logger PAC designed by ICP
34. 0 Module Data RS 485 address 15 I 7000 Module Data RS 485 address 16 Modbus RTU Module Data Modbus RTU address 17 Modbus RTU Module Data Modbus RTU address 18 Modbus RTU Module Data Modbus RTU address 19 Modbus RTU Module Data Modbus RTU address 20 http wise icpdas com 1 p lt 6 ICP DAS WISE User Manual The memory block for the I O Table Data The I O Data Table Configuration setting of the Active I O Sending function will be 1230 1529 stored in this block The maximum address length is 300 There are two data arrangement options Coil and Register and Register Merge Coil into Register 1 WISE 580x System Data This block stores the system information of WISE 580x shown as below Parameter Name Modbus Length Data Range Address Type Coil Output Unit Coil 8 Bits SMS switch 00001 0 OFF 1 ON Input Register Unit Register 1 6 Bits Web Port Modbus TCP NetID micro SD free space Holding Register Unit Registe Ethernet IP 1 Ethernet IP 2 Ethernet IP 3 Ethernet IP 4 Subnet Mask 1 Subnet Mask 2 Subnet Mask 3 Subnet Mask 4 http wise icpdas com r 16 Bits 0 60000 0 255 0 100 117 ICP DAS WISE User Manual Gateway 3 40010 Int 0 255 2 XW Board Data This block stores information of XW Board For different XW Board modules the data will be store in different address the following sections shows corresponding add
35. 00 0 0 0 0 The AO channels DO channels Coil Output and Holding Register on WISE 580x will automatically appear on the list To include subjects other than I O channels in the THEN ELSE Action statement they have to be pre defined in Advanced Setting first The subjects that already being defined in Advanced Setting will appear on the dropdown list of THEN ELSE Action Select the component for Action statement from the combo box and then click the right side button a window will pop up for you to edit detailed information The THEN Action statement will be executed only when the result of IF condition statement is found true otherwise the ELSE Action statement will be executed In order to meet application requirement for some Actions WISE offers options to execute the Action one time or repeatedly One Time when the IF Condition is TRUE this Action will be executed once and only once This Action will not be executed again until the IF Condition turns to be TRUE again Repeat when the IF Condition is TRUE this Action will be executed repeatedly until the IF Condition turns to be FALSE http wise icpdas com 89 ICP DAS WISE User Manual ala A Condition ISE Bl 2 One Time O Repeat One Time O Repeat Figure 6 16 One Time Action amp Repeat Action Items gt lt 6 2 1 AO You can execute an action in AO channel of XW Board o
36. 107 ICP DAS WISE User Manual 10 Firmware Update 10 1 Introduction WISE Firmware Uploader is a software tool provides a user friendly interface to easily update WISE firmware that runs on WISE hardware devices With a few clicks you could upload the latest WISE firmware to the hardware System Requirements Operating System Windows Server 2003 Windows Server 2008 Windows XP Windows Vista and Windows 7 Make sure you have installed Microsoft NET Framework Version 2 0 or later B You can download Microsoft Net Framework Version 2 0 from the link below http www imicrosoft com downloads details aspx FamilyID 0856ea cb 4362 4b0d 8edd aab 1 5c5e0415 amp DisplayLang en B You can download Microsoft Net Framework Version 3 5 from the link below http www microsoft com downloads details aspx familyid 333325F D AE52 4E35 B531 508D977D32A6 amp displaylang en Please note Make sure you use WISE Firmware Uploader V2 2 or later to perform WISE 580x firmware update 10 2 Install Uninstall WISE Firmware Uploader 10 2 1 Install WISE Firmware Uploader Follow the steps below to install WISE Firmware Uploader Obtain the WISE Firmware Uploader V2 2 setup file WISE Firmware Uploader Setup V2 2 exe or later Double click the setup file to install the file you will see a window pop up as below click Next to continue http wise icpdas com 108 ICP DAS WISE User Manual a WISE Firmware Uploader versio
37. 144 N 1 Holding Register Unit Register 16 Bits 10140 N 40142 4N 101444N 401464 N http wise icpdas com N es T T T pi pi pi pi Q Q Q Q amp amp amp amp NO Int 0 65535 Int 0 65535 Int 0 65535 Int 0 65535 Int 0 65535 By Channel Type Setting By Channel Type Setting By Channel Type Setting By Channel Type Setting 125 ICP DAS WISE User Manual 1 7033 3 AI channel Parameter Name Modbus Length Data Range Address Type Input Register Unit Register 16 Bits By Channel AI Ch 0 30140 N 2 Float Type Setting By Channel AI Ch 1 30142 N 2 Float l Type Setting By Channel AI Ch 2 30144 N 2 Float Type Setting 1 7000 DI DO Module Maxinum 16 DI channel 16 DO channel According to the channel numbers of I 7000 DI DO Module you can look up the address of the I 7000 DI DO Module channel from the following table Parameter Name Modbus Length Data Range Address Type Coil Output Unit Coil 8 Bits http wise icpdas com 126 ICP DAS WISE User Manual DI Ch 1 10141 N DI Ch 2 10142 N DI Ch 3 10143 N 0 OFF 1 ON DI Ch 4 10144 N Eu OFF 1 Di Counter0 3040 N 1 m O6 Di Gouner1 301eN 1 m 0265535 Di Counter 3082N 1 m os Di Gounter3 303eN 1 m 0265535 Di Gounter4 3014an 1 m os Di Gounters 30185 N 1 m os Di Gounter 3064N 1 m 065 Ci fn Ci fm Ci om O O 1 I n
38. 2 SMS alarm settings It allows to send pre set SMS alarm to specific phone numbers For SMS command receiving function WISE 5801 allows to set up maximum 3 authorized phone numbers to receive SMS commands WISE 5801 will execute the commands received from authorized phone numbers only There are three types of SMS commands Retrieve real time channel data you can retrieve specific channel real time data one SMS command message can require up to 10 channel data values To retrieve the channel data of WISE 5801 follow http wise icpdas com 70 ICP DAS WISE User Manual the following coding rules to send a SMS command to WISE 5801 Initiate each data string with a the symbol indicates the string following after is real time data A indicates the module type B Real Time Data Code indicates module location A can al be set as x m n For X W board SAB aiC put x in A skip B For I 7000 di modules put m in A put its location address in B 1 16 For ci DI Counter or RTU Modbus RTU device put n in A and put its location address in co B 17 20 For Internal Register Data skipped both A and B ri RTU Input Register Data the channel don t input a oo ir Internal Register non existing index number Data ro RTU Holding C indicates the index number of Register Data Figure 5 16 SMS Command Data Retrieve Coding Rules Modify channel data WISE 5801 al
39. 3 Proute le Naime Se Ue DAC ad nude 24 Figure 4 2 The Name location on WISE Web Page ccecccccccccceeeeeeeeeeeeeeeeeeeees 24 Preure 45 Time Sethi Pag Cs nn a mien nine 25 Figure 4 4 Communication setting page ss 26 Fig re 4 5 Password Sete DAS Use midi 21 Froure 4 0 XW Board seting DAS ie ner T EEE 28 Figure 4 7 XW Board DI attribute setting page cccccccccccccssssseeeeeceeeeeeeaeeseeseeeees 29 Figure 4 8 XW Board DO attribute setting page 30 Figure 4 9 XW Board AI attribute setting page 31 Figure 4 10 AI Deadband Operation gt or gt a numerical value eeeeeeeees 32 Figure 4 11 AI Deadband Operation lt or lt a numerical value seeeeecesssessssss 32 Figure 4 12 AI Deadband Operation a numerical value 33 Figure 4 13 Figure 4 14 Figure 4 15 Figure 4 16 Figure 4 17 Figure 4 18 XW Board AO attribute setting page 33 FF7000 mod le setine p l renosicern MA ARE 34 7000 modules MSC sn Mn nn eras 35 I 7000 module DI attribute setting page eoonosssssoerrssssssssseerssssssssse 36 I 7000 module DO attribute setting page 37 I 7000 module AI attribute setting page 38 http wise icpdas com 5 ICP DAS WISE User Manual Figure 4 19 I 7000 module AO attribute setting page 39 Figure 4 20 Modbus RTU Slave Module Setting Page ec eeccccccceasseeeeeeeeees 40 Figure 4 21 Modbus RTU Slave Module List 42 Figure 4 22 M
40. 5 6 AO 7 8 In the SMS Amount field specify the total number of SMS alarm messages you are going to use from the dropdown list In the Index field specify the SMS index number to be set up from the dropdown list In the Phone Number field input the phone numbers to receive the SMS alarm messages The SMS can be sent to multiple receivers Separate the phone number by Enter the content in the Message field If the Unicode mode is adopted the length of the content cannot exceed 70 characters If the Unicode mode is not selected support English characters the length of the content limit is 160 characters To quickly add a real time I O channel value into the SMS content use the I O channel selection interface shown as figure above to add the I O channel value encoded string into the SMS content Repeat steps iv vi After all SMS alarm settings are completed click Save button to save the changes http wise icpdas com 75 ICP DAS WISE User Manual 6 Rules Setting After finishing all Advanced Setting configurations you can start to edit IF THEN ELSE rules Click the Rules Setting button a Rule Manager table will appear and the list of rules will be displayed on the left side of the page At the left side of the page the status of each rule will be displayed And at the right side of the page will show detailed content of each rule that was previously defined The rule settin
41. COM2 RS 485 Link Y L1 Speed G VEEL N 3 Power off WISE 580x and switch Rotary Switch back to 0 position Power on WISE 580x again the WISE 580x will be restored to factory default settings http wise icpdas com 133
42. Command setine Piger E tenais 87 Figure 6 16 One Time Action amp Repeat Action Items 90 Figure 0 17 AO action Setting pa Ce Meet nn aide sen 90 Fisure 618 DOactonse nE DAS Ru elodie 91 Figure 6 19 DI Counter action setting PASS ren nn mena nine 92 Figure 6 20 Coil Output action setting page 92 Figure 6 21 Holding Register action setting page ccccccccsssseesseeceeeceeaaeesseseeeess 93 Figure 6 22 Internal Register action setting page ccccccccccssssseeseeceeeeeeaeeeseeeeeess 94 Preure 6 23 Timer ACH ON setting Pa SO cnaissi does 95 Figure 6 24 Schedule action setting page nn tiennent 96 Figure 6 25 Email action setting page ss 96 Figure 6 26 CGI Command action setting page cccccccccccccsseeeseeceeeeceaaeesseeeeeees 97 Figure 6 27 Recipe action setting 9d GC ies SL LAN Re oeusteuuniaeee 97 Figure 6 28 Rule Status action setting page 00 cceecssscccccccceesseeeeeceeeeeeaeeeeseeeeeess 98 Figure 6 29 Data Logger action setting page 99 Figure 6 30 SMS Alarm Action Setting Page 99 Fiere 0517 Clear Say CK NCS Ra dt dci eau ae 101 Figure 6 32 Rule Setting main Page nie tee este and 101 Figure 6 33 Rule Manager setting pages santa eMaiiinedaealisnee 102 Figure 6 34 Rule Copy setine pase siere e a a i 102 Preure 6 33 R le Reset SENS PASS nn Monnier A 103 Figure 6 36 Rule Reorder setting page ss 103 Figure 6 37 Rule Swap setting page ss 104 Figure 7 1 Remind the
43. DA software WISE 580x provides I O Data Table Configuration function It allows to rearrange the I O channels data from different I O modules and puts them into a continuous Modbus address memory block and then SCADA software can retrieve all I O channels data http wise icpdas com 66 ICP DAS WISE User Manual from different modules by using one single Modbus command Comparing to traditional polling mechanism it will greatly save time and polling attempts In addition to the I O Data Table Configuration function WISE 580x also provide the Active sending of I O Data Table function It allows WISE 580x to actively send the content of I O Data Table to SCADA software through Modbus TCP protocol without polling mechanism from SCADA software Please note The SCADA software must equip the Modbus TCP Slave function to receive the content of I O Data Table that sent by WISE 580x Active I O Setting Page Enable I O Data Table configuration Active sending of I O Data Figure 5 11 Active I O Setting page Follow the following steps 1 Select Enable I O Data Table configuration to enable the I O Data Table function then the I O Data Table and the configuration UI will be shown as follow Register Merge Coil into Register nn Receiver Start Address co ey Receiver Start Address ET 1 No Coil or Register exist Figure 5 12 1 0 Data Table configuration UI
44. DAS WISE User Manual Real time monitoring system status of controllers WISE 580x supports Modbus TCP RTU Protocol for you to perform real time monitoring and control of the controllers Please refer to Appendix for the mapping table of controller system information and Modbus Address In addition WISE provides an easy to view HMI web interface for real time monitoring It allows you to get important real time system information even without SCADA software Password protection for access control WISE HMI web page offers password protection After getting in the webpage you will be required to input the password before editing logic rules In addition WISE 580x provides monitoring web pages specifically designed for cell phone The access control restricts the access to the webpage to prevent unauthorized modification it allows to set up passwords for guest and administrator only the authorized users will be allowed to modify the channel data Provides SMS command receiving function and alarm notification function Only apply to WISE 5801 WISE 5801 equips SMS command receiving and alarm message notification function It allows to include SMS alarm sending action into logic rules to send a pre set SMS message to related personnel when an event occurs In addition WISE 5801 allows to receive the SMS commands sending by specific phones numbers to perform tasks such as real time channel monitoring channel data modification and log
45. DAS that functions as control units for use in remote logic control and monitoring in various industrial applications WISE 580x offers a user friendly and intuitive HMI interface that allows you to implement control logic on controllers just a few clicks away no programming is required With this powerful and easy to use software it will minimize the learning curve shorten time to market and dramatically reduce the labor and cost spent on system development Through Web browser you can access Web Server on WISE 580x to perform tasks such as logic rule edition and download WISE 580x equips an IF THEN ELSE rule engine that will check whether the rules are valid or not and determine the execution of actions under specific conditions for examples setting up I O channel values perform scheduled and Timer tasks sending Email under a specific condition In addition through the Modbus TCP Protocol it enables SCADA software to control and monitor I O channel or system status on controllers in real time In addition to merits inherited from the previous WISE series WISE 580x even provides more supports in I O functions It allows to connecting with a wide range of the XW Board I 7000 Remote I O modules and Modbus RTU Slave modules enables to freely choose the most suitable I O modules With the microSD card it provides Data Logger function to real time record the I O data of the controller and allows to send the data files by FTP or Email at a schedu
46. ICP DAS WISE oy lee Manual ISE 580x Series Version 1 30 Sas ICP DAS WISE User Manual Warning ICP DAS Inc LTD assumes no lability for damages consequent to the use of this product ICP DAS Inc LTD reserves the right to change this manual at any time without notice The information furnished by ICP DAS Inc is believed to be accurate and reliable However no responsibility 1s assumed by ICP DAS Inc LTD for its use or for any infringements of patents or other rights of third parties resulting from its use Copyright and Trademark Information Copyright 2009 by ICP DAS Inc LTD All rights reserved worldwide Trademark of Other Companies The names used for identification only maybe registered trademarks of their respective companies License The user can use modify and backup this software on a single machine The user may not reproduce transfer or distribute this software or any copy in whole or in part http wise icpdas com 9 ICP DAS WISE User Manual 10 Table of Contents TTPO CU CHON SSSR de diese che le eat 9 Belore COnMe CUO ESS RS E 14 2 1 Network CONTISUTATON 225 558 re en e E EE 14 2 2 7000 Module Parameter Settings cccccccccccccssssesseeeceeeceeseneeeseeeeeees 16 WISE Web Pace OVNI nn NN NE 19 3 1 Kocie Sete ue kes anar E TA A 19 32 Channel Monitoring PASS anis een 22 BASIC SEE net rea ain na A ae E ae dut 24 4 1 Name SOURIS A een nie r a aneoideentusue a
47. M CNE 0 mV 30 mV UN R 15 mV 15 mV vi 0 0 mV 30 mV ma ms 15 mV 15 mV v 0 mV 30 mV 15 mV 15 mV 0 mV 30 mV Figure 4 18 1 7000 module Al attribute setting page The settings are as follow Polling Timeout The time for WISE 580x to send command to the I 7000 module and wait for the response the unit will be ms Temperature Unit Specify temperature measurement unit for modules that allows for temperature measurement such as I 7005 I 7011 I 7013 I 7015 I 7018 and I 7019 the temperature units can be set as degree Celsius or degree Fahrenheit Nickname For you to define nicknames for each I O channel this nickname will be displayed on the Channel Status page Type Select the appropriate AI signal input type Deadband Please refer to section 4 8 XW Board AI channel settings for Deadband settings Scale Please refer to section 4 8 XW Board AI channel settings for Scale settings After all AI channel settings are completed click Save button to save the changes http wise icpdas com 38 ICP DAS WISE User Manual 4 6 4 1 7000 module AO channel setting I 7000 module AO Channel Setting page is shown as follow using I 7024 as an example l 7024 Module Setting mn x Polling Timeout 300 milliseconds e E o o Goom
48. M2 http wise icpdas com 35 ICP DAS WISE User Manual 4 6 1 l 7000 module DI channel setting The I 7000 module DI Channel Setting page is shown as follow using I 7052 as an example 1 7052 Module Setting name mn Polling Timeout 300 milliseconds Reset Counter When 0 Figure 4 16 l 7000 module DI attribute setting page The settings are as follow Polling Timeout The time for WISE 580x to send command to the I 7000 module and wait for the response the unit will be ms Nickname For you to define nicknames for each I O channel this nickname will be displayed on the Channel Status page Reset Counter When Power On When the Reset Counter When Power On is selected it means the system will reset the DI counter of this I 7000 module to the default value when WISE 580x power on After all DI channel settings are completed click Save button to save the changes Please note the DI channel counter of I 7000 module is counting by default Falling edge detection ON to OFF if you would like to select other counting type please use DCON Utility to set up the counting type 4 6 2 l 7000 module DO channel setting I 7000 module DO Channel Setting page is shown as follow using I 7060 as an example http wise icpdas com 36 ICP DAS
49. RD DWORD 128 ICP DAS WISE User Manual 7 Modbus RTU Module Data This block stores all Modbus RTU modules I O channel data in WISE 580x In addition to I 7000 modules and XW Board each WISE 580x supports up to 4 Modbus RTU Slave modules Modbus RTU Address Range 17 20 The starting Modbus address of the data block is 780 and each Modbus RTU module takes 100 addresses Please refer to the following table 780 879 Modbus RTU Module Data Modbus RTU address 17 880 979 Modbus RTU Module Data Modbus RTU address 18 980 1079 Modbus RTU Module Data Modbus RTU address 19 1080 1179 Modbus RTU Module Data Modbus RTU address 20 The allocation of the Modbus address of I O channel for each Modbus RTU module is in sequence arrangement from the module starting address Please refer to the following example The Modbus RTU module s name is Devicel the following figure shows the settings of this module For this Modbus RTU module s address is 17 its starting address in WISE 580x Modbus address table will be 780 http wise icpdas com 129 ICP DAS WISE User Manual Modbus RTU Module Setting 1300 mi liseconds WISE 5800 Local Address Coil Output 0x 780 Address 782 Ty pe 783 32 bit Floating Point Expand All Collapse All mi on T The allocation of the Modbus Address in WISE 580x for the Coil Output setting of this Modbus RTU module Devicel is shown as below http wise
50. SE 580x COM2 all I 7000 modules Baudrate have to be set the same as well Checksum set to be Disable The default setting on WISE is Disable You can change to Enable but the setting on WISE also has to be changed to Enable to ensure this function Data format set to be 2 s Complement Except for I 7024 it only uses Engineering Unit format Parity Option set to be None Parity N 8 1 Complete the other settings as required http wise icpdas com 18 ICP DAS WISE User Manual 3 WISE Web Page Overview WISE 580x equips v2 20 or later firmware it provides two web page interfaces Logic Setting page and Channel Monitoring page The Logic Setting page allows to perform logic setting on WISE controller And the Channel Monitoring page allows to monitor or modify the I O channel data on WISE Controller 3 1 Logic Setting Page When you connect to WISE 580x by Web browser IE Firefox or Chrome browser WISE will automatically connect to the Logic Setting page In order to get a better operation experience 1280x1024 resolution is recommended The Logic Setting page of WISE 580x controller is shown as below Login ev _ Web Inside Smart Engine Password aE Webpage Logic Setting Channel Monitoring E Remember me j SD w Web Anywhere Automation Anywhere ad Welcome to ICP DAS WISE Logic Setting page WISE Web page is a web based user interface for use in s
51. WISE User Manual 1 7060 Module Setting Polling Timeout 300 milliseconds Niko i Sn Sam Figure 4 17 l 7000 module DO attribute setting page The settings are as follow Polling Timeout The time for WISE 580x to send command to the I 7000 module and wait for the response the unit will be ms Nickname For you to define nicknames for each I O channel this nickname will be displayed on the Channel Status page After all DO channel settings are completed click Save button to save the changes Please note 1 To setup the Power On Value on DO channel for each I 7000 module please use the DCON Utility to setup the value 2 The DO channels on I 7000 modules do not provide Pulse Output function 3 The DO channels on I 7000 modules do not provide Counter function 4 6 3 l 7000 module Al channel setting I 7000 module AI Channel Setting page is shown as follow using I 7018 as an example http wise icpdas com 37 ICP DAS WISE User Manual l 7018 Module Setting Polling Timeout nas i 15 mV 15 mV vi 0 mV 30 mV M S 15 mV 15 mV v 0 mV 30 mV mm 15 mV 15 mV v Ld 0 mV 30 mV E 15 mV 15 mV v 0 30 mV 15 mV 15 mV
52. age 6 2 14 SMS Alarm WISE 5801 allows to send a specific SMS Alarm message in an Action The setting page is show as below SMS Alarm Action Setting O index O SMS Alarm Infomation Phone Number 0918765432 The devices temperature is too high Figure 6 30 SMS Alarm Action Setting Page Please follow the steps below 1 In the Index field specify the SMS Alarm index number you want to execute in Action from the dropdown list 11 The selected SMS Alarm message such as phone numbers and message content will be displayed for you to verify if this is the http wise icpdas com 99 ICP DAS WISE User Manual SMS Alarm you want to send i Click Save button to save the settings The popup window will be closed and will return to the rule setting page http wise icpdas com 100 ICP DAS WISE User Manual 6 3 Summary of the Rules After you finish editing all IF condition and THEN ELSE action statements for a rule return to the Rules Setting page and click Save to save all settings of this rule Please note if you want to clear previous settings after you click Clear button you have to click Save to make sure this Clear status is saved Rules ons page is shown as below DO Condition1 Al F4 es fi ston O Ah nb eee Condition2 Action None B T LUER None Bl Actions 3 Action3 ne B Figure 6 31 Clear Save Rules
53. age it will display current network configuration and Modbus settings that are automatically read from the hardware devices For Ethernet settings you can modify IP Mask Gateway Web Server Port DNS Server IP configuration of the hardware devices in this section After you finish modification click Save and then all changes will be saved and written back to the hardware For Modbus settings you can also modify the Modbus NetID in the same way WISE http wise icpdas com 26 ICP DAS WISE User Manual Firmware v2 l and later supports Modbus RTU Slave function and it enables to communicate with Modbus RTU Master devices for data transmission via WISE 580x COMI To enable Modbus RTU Slave function for communicating with devices that equip Modbus RTU Master function click Enable Modbus RTU Slave from COM1 and set up COM1 settings After finishing the settings click Save to save the change Please note i WISE adopts Google DNS server as system default DNS server the default IP is 8 8 8 8 the IP can be modified to other DNS server IP 11 If you make any modification to the network configuration the hardware device will reboot and re connect to the web page automatically about 5 seconds later 4 4 Password Setting Password Setting allows you to change the password that is required when access the controller The Password Setting page is as follow Password Setting Page Admin Password Original Passwo
54. age is shown as below There are three operation styles for AI Deadband Detailed description is as below The AI Channel setting in following examples is OmA 20mA a In the IF Condition when AI gt or gt a numerical value Assuming the Deadband value is set to be 2 mA and the following statements are defined in the related logic Rule IF AI0O gt 10mA THEN DO ON ELSE DO OFF that means when AIO receives a signal that exceed 10mA the DO channel will change to ON immediately however when the AIO channel value drops and becomes lower than 10mA the DO channel will not change back to OFF immediately until the value reaches 8mA 10mA minus the Deadband value 2mA as shown in following figure http wise icpdas com 31 ICP DAS WISE User Manual IF Al gt 10mA THEN DO ON ELSE DO OFF 10mA 8mA F ivsseernsssernsssnsnisssrsnsssennisssrnnssersnass lt DO OFF lt DO OFF lt DO ON Figure 4 10 Al Deadband Operation gt or gt a numerical value b In the IF Condition when AI lt or lt a numerical value Assuming the Deadband value is set to be 2 mA and the following statements are defined in the related logic Rule IF AIO lt 10mA THEN DO ON ELSE DO OFF that means when AIO receives a signal which is lower than 10mA the DO channel will change to ON immediately however when the AIO channel value exceed 10mA the DO channel will not change back to OFF immediately until the value reaches 12mA
55. allows to meet various requirements from the clients Provide Timer and Schedule operation WISE 580x features two kinds of timing functions Timer and Schedule It allows you to perform specific tasks such as time delay or schedule specific date or time for control logic execution To ensure the accuracy of the WISE controller clock it also has the ability to sync the clock to an SNTP time server for time synchronization through the network Provide Email message and CGI command sending functions WISE 580x supports Email message and CGI command sending functions Email and CGI command functions are important function for real time message communication The sending action can be added to the logic edition as part of logic control to provide real time message transmission or sending CGI command for device control in response to specific events Recipe function for Group Action operation WISE 580x provides Recipe function that allows to execute a sequence of actions previously saved in the Recipe to response to IF THEN ELSE logic rules Conditions You can create different Recipe sets to meet various requirements for different applications Data Logger function With the microSD card WISE 580x provides Data Logger function to real time record the I O data of the controller and sends the data files by FTP or Email to the control center for further administration management or data analysis http wise icpdas com 11 ICP
56. chedule 1 Enable One Time Rule16 Rule17 Rule18 Rule19 Figure 6 32 Rule setting main page Click Rules Setting button to display detailed rules description Rules can be downloaded to the hardware device immediately after you successfully set up one or more rule s http wise icpdas com 101 ICP DAS WISE User Manual 6 4 Rule Manager The Rule Manager allows easy modification and deployment with existing rules By a few simple steps you can easily change the rule orders or make modification with previously edited rules The Rule Manager table is shown as below Rule Manager Figure 6 33 Rule Manager setting page Rule Manager offers 4 functions Copy Copy the content of previously edited rule to another rule Click Copy button a window as shown below will pop up Select the source rule from the first field and then select the destination s from the second fields multiple rule destinations is allowed Click Save button to copy the content of the source rule to all destination rules Rule Copy Figure 6 34 Rule Copy setting page http wise icpdas com 102 ICP DAS WISE User Manual Reset Allows to clear rule content of previously edited rules Click Reset button a window as shown below will pop up Rules that are previously edited will be listed on the page select the rule to be cleared and then click Save button the rule you select will be
57. d click Save button to save the changes 5 4 Email Setting WISE supports up to 12 Email messages This function allows sending pre input Email message s to pre set Email receiver s under certain conditions The configuration page is shown as below Email Setting Page Email Amount SMTP Server IP IP or Domain Name E Authentication Login ID Password Sender Email Address Andy icpdas com 2nd Receiver Email Address 3rd Receiver Email Address 4th Receiver Email Address Temperature Report The Device Temperature is Report 3 Content Note The length of the message cannot exceed 160 characters Yv Insert Real Time Variable Module 7017 1 Chl 4 Figure 5 5 Email setting page http wise icpdas com 59 ICP DAS WISE User Manual Follow the following steps i Specify the numbers of email messages you want to set up from the dropdown list of the E mail Amount field li Specify the email group number from the dropdown list of the Index field ii Enter the IP or the domain name of the SMTP server in the SMTP Server field iv If SMTP server requires account and password validation please select the Authentication Checkbox and continue steps v vi to login into the SMTP server If SMTP server don t need account and password validation uncheck the Authentication Checkbox and skip steps v vi go directly to step vil v Enter the SMTP se
58. ddress Type Holding Register Unit Register 16 Bits 2 Internal Register 08 40054 Internal Register 09 40056 Floating Point Floating Point http wise icpdas com 121 ICP DAS WISE User Manual 6 1 7000 Module Data This block stores all I 7000 modules I O channel data Each WISE 580x supports up to 16 I 7000 modules The starting Modbus address of the data block is 140 and each I 7000 module takes 40 addresses The Modbus address of I O channel of each module is in sequence arrangement from the starting address The following is an example of an I 7000 module using RS 485 Address 1 AI Channel DO Channel DI Channel AO Channel 140 179 Value amp DI Value Value Value Counter Vale I 7000 module Modbus Address starts from different initial address therefore the I O channels Modbus Address of the modules will also be different if it starts from different RS 485 address To calculate the I O channels Modbus Address of I 7000 module please follow the steps below Get the RS 485 address of the I 7000 module Calculate the parameter N by the following format N I 7000 RS 485 address 1 x 40 Check the I 7000 module Modbus TCP Address Table to calculate the I O channel Modbus TCP Address with N value for the I 7000 module According to I 7000 module RS 485 addresses each module s N value is different For example The N value of I 7000 module with RS 485 Address 1 is 1 1 40 O the N value of I
59. e 6 2 4 Coil Output You can execute an action in Coil Output channel of Modbus RTU module in the THEN ELSE Action statement the editing page for Coil Output Action is shown as follow Coil Output Action Setting Module amp Address Address 0 Address Value Figure 6 20 Coil Output action setting page Follow the following steps 1 Select the Coil Output from the dropdown list of channel field in the Module amp Address section 11 Specify the output value of Coil Output from the dropdown list of the Address Value field The output value can be OFF or ON http wise icpdas com 92 ICP DAS WISE User Manual i Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 2 5 Holding Register You can execute an action in Holding Register channel of Modbus RTU module in THEN ELSE Action statement the editing page for Holding Register Action is shown as follow Module amp Address Devicei 17 M Save Figure 6 21 Holding Register action setting page Follow the following steps i From the dropdown list of the Module amp Address field select the Holding Register address index to execute actions 11 Specify the Operator in the Operator field The 3 operators are as follow Indicate assign the new Holding Register address value as the value in Value field Indicate assign
60. e note the DO channel of XW Board does not offer Counter function 4 5 3 XW Board Al Channel Settings The XW Board AI Channel Setting page is shown as follow using XW304 as an example http wise icpdas com 30 ICP DAS WISE User Manual XW Board Setting Page JI Attribute DO Attribute AO Attribute i Il p 0 0 0 0 0 0V 5V 0V 5V 0V 5V 0V 5V 0V 5V 0V 5V MIN 0 MIN 0 MINO MINO MINO MNo MAX 0 MAX 0 MAXO MAX0 MAX0 MAX Deadband Figure 4 9 XW Board Al attribute setting page The settings are as follow Nickname For you to define nicknames for each I O channel this nickname will be displayed on the Channel Status page In the Scale field AI channel raw data can be set to operate with linear proportion between MIN and MAX values The IF Condition will use the adjusted value in the logic Rule operation and the AI value retrieved from Modbus TCP and Channel Status page would be the adjusted value The default value for MAX and MIN is 0 it means the Scale function is disabled Deadband In order to avoid signal oscillation that may result in instability to the status changes you can set up a Deadband value for the AI channel to reduce the oscillation effect to the channel value The AT attribute configuration p
61. ecute this sequence of actions that was previously stored in the Recipe when an IF condition is matched A Recipe contains a sequence of actions therefore we can say a Recipe is a macro for Actions The configuration page for Recipe Setting is shown as below Recipe Amount Recipe Setting Page Add Figure 5 8 Recipe setting page Follow the following steps 1 Select the total number of Recipe you are going to use from the dropdown list of the Recipe Amount field 11 Assign an index number to the Recipe from the dropdown list of the Index field iii Select an Action type from the dropdown list of the Action field IV Click the Add button An Action Setting page will appear for you to set up related Action Settings please refer to THEN ELSE Action V After you finish setting up Action Settings the page will refresh automatically and the Actions will be listed on Recipe One Time Repeat One Time One Time Figure 5 9 Recipe Action Management http wise icpdas com 62 ICP DAS WISE User Manual In order to meet application requirement for some Actions WISE offers options to execute the Action one time or repeatedly One Time When the IF Condition is TRUE this Action will be executed once and only once This Action will not be executed again until the IF Condition turns to be TRUE again Repeat When the IF Condition is TRUE this Action will be executed repeatedly until the IF Condi
62. edule you want to set up by selecting its index number from the dropdown list of the Index field iii Specify the initial status of each schedule from the dropdown list of the Initial Status field Start indicates the schedule will be activated as soon as the hardware device is power up Stop indicates the schedule will remain inactive when the hardware device is power up it will not be activated until being triggered under certain conditions iv Set up the Year and Month for this Schedule execution duration After you specify the Year and Month in the Date section the calendars corresponding to the Year and Month you specified will appear as shown below http wise icpdas com 57 ICP DAS WISE User Manual Vi fe lo mo wr2vo mjo m Remove ma mjo mo mhie mo mjo m Remove Clear All Mark All _ iIin Range Weekday 2011 6 3 0 w GE R 2 m TS BEEBE mn al ES a _ 5 Q 5 D n n amp gt 4 Q 5 j c n n re n SES RCE Base f N e BREN BRae v Figure 5 4 Schedule Calendar setting page In the Time field input the schedule In Range time You can input up to 12 time zones in a specific date Select the start time and the end time from the dropdown list Click Add button to add a new time zone Please note the time zones y
63. ements the editing page for Input Register Condition Setting is shown as below Input Register Condition Setting Device1 17 M Assign Value as M vw Address 2 v 10 Figure 6 9 Input Register condition setting page Follow the following steps 1 Specify the module and address from the dropdown list of the Module amp Address section that you are going to include its value in the IF condition statements 11 Set up the expression statement for this channel value Select an 99 99 299 99 operator from gt lt gt or lt ii And then specify the evaluation value If this Input Register value match the evaluation criteria the result of this condition evaluation will be true iv Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 1 7 Holding Register Holding Register value from Modbus RTU module can be included in the IF condition statements the editing page for Holding Register Condition Setting is shown as below Device1 17 Address LL Figure 6 10 Holding Register condition setting page Follow the following steps i Specify the module and address from the dropdown list of the Module amp Address section that you are going to include its value http wise icpdas com 83 ICP DAS WISE User Manual in the IF condition statements
64. etting up logic function performing upload or other operations run on ICP DAS hardware devices English Hardware Information Traditional Chinese Et 2 20 O Simplified Chinese REX 2 04 11 a WE Sa PU 01 y Onine 5 7088 online 16 1 7080 Online adress mame swns 18 Device 1 Offline 19 Device 2 Online 20 Device 3 Online l 7000 Module Modbus RTU Module Configuration Procedure Set up Name Time Network Password and configuration for oe connected I O modules Figure 3 1 Main page of the Logic Setting page You will be required to enter the password to login into the page before performing logic settings The login section is on right upper corner as shown below http wise icpdas com 19 ICP DAS WISE User Manual Login Password as Webpage Logic Setting Channel Monitoring Submit E Beene Figure 3 2 Login page of the Logic Setting page Both default passwords set for Administrator and Guest are wise You can follow the instruction in 4 4 Password Setting section to modify the password Please note that the Logic Setting page only allows Administrator to log in If you only need to view the channel data please select the Channel Monitoring option under the Web Page selection It will automatically be directed to the Channel Monitoring page The Logic Settin
65. f 30040 register and r2 represent the address of 30041 register to join rl and r2 to a floating point in the system is big endian system you will need to call float value register_to_float r1 r2 Instead 1f the system is little endian system you will need to call float value register_to_float r2 r1 Please note 1 If you are not sure your editor belongs to which system try both systems to find the accurate one 2 The way to join the two registers value into DWORD is similar to Floating point change the return value to DWORD or Unsigned Long http wise icpdas com 115 ICP DAS WISE User Manual WISE 580x Modbus Register Address Table Modbus 00000 10000 30000 40000 Address Coils Output Discrete Input Input Registers Holding Registers WISE 580x System Data XW Board Data RS 485 module information RS 485 module Error Code Internal Register Data W I 7000 Module Data RS 485 address 1 I 7000 Module Data RS 485 address 2 I 7000 Module Data RS 485 address 3 I 7000 Module Data RS 485 address 4 I 7000 Module Data RS 485 address 5 I 7000 Module Data RS 485 address 6 I 7000 Module Data RS 485 address 7 I 7000 Module Data RS 485 address 8 I 7000 Module Data RS 485 address 9 I 7000 Module Data RS 485 address 10 I 7000 Module Data RS 485 address 11 I 7000 Module Data RS 485 address 12 I 7000 Module Data RS 485 address 13 I 7000 Module Data RS 485 address 14 I 700
66. figuration of the Modbus RTU Slave modules for use in the IF THEN ELSE rules edition Each WISE 580x controller can connect up to four Modbus RTU Slave Modules The Modbus RTU address range starts from 17 to 20 The setting page is shown as follow Modbus RTU Module Setting Page Baudrate COM2 19600 bps Silent Interval 48 milliseconds De Polling Timeout 300 _milliseconds Range 1 10000 Timeout Retry Interval 5 seconds Range 3 65535 Modbus RTU Module List of COM2 No Modbus RTU Module Exist Figure 4 20 Modbus RTU Slave Module Setting Page Follow the following steps 1 11 In the Baudrate COM2 field select the WISE 580x COM2 data transmission Baudrate from the drop down list The Baudrate has to be set the same as the Baudrate of Modbus RTU Slave modules Please note on the I 7000 Module Setting page there is a COM2 Baudrate setting as well please note that all I 7000 modules and Modbus RTU Slave modules that are connected to the WISE 580x COM2 must be set to the same Baudrate Select the data transmission Baudrate for WISE 580x COM2 and then the system will automatically provide a proper value in the Silent Interval field For each Modbus RTU Slave device has different Modbus command process capability the response time for sending result from Modbus RTU Slave device to controller might be different User can adjust this value to most appropriate time interval such as extend th
67. g page after login is shown as bellow NU i Web Inside Smart Engine 1 Basic Setting 2 Advanced Setting 3 Rules Setting Web Anywhere Automation Anywhere Channel Status Upload from Module Download to Module d Welcome to ICP DAS WISE Logic Setting page WISE Web page is a web based user interface for use in setting up logic function performing upload or other operations run on ICP DAS hardware devices English Hardware Information Traditional Chinese br WISE Engine Version 2 20 Simplified Chinese 22 ener 2 04 11 WISE 5801 Board XW107 l 7021 Online l 7000 Module Se 7088 Online 7080 Online 19 20 Modbus RTU Module Configuration Procedure Set up Name Time Network Password and configuration for Figure 3 3 After login the Logic Setting page Six buttons will appear on the upper part of the Web page Basic Setting Advanced Setting Rules Setting Channel Status http wise icpdas com 20 ICP DAS WISE User Manual Upload from Module Download to Module The main page will show the version of WISE 580x firmware WISE Engine Version the OS version of the controller and the controller module name A list of I O devices that currently are connected to the WISE 580x such as the XW Board I 7000 modules and Modbus RTU modules will be displayed as well And the connection s
68. g page is shown as below 1 Basic Setting 2 Advanced Setting 3 Rules Setting why _ Web Inside Smart Engine Web Anywhere Automation Anywhere Channel Status Upload from Module Download to Module Rule Manager Enable No d Rule Rule2 Rule3 Rule4 Ruled Rule6 Ei Rule7 Rules Rule9 Rule10 Rule11 Rule12 Rule13 Rule14 Rule15 Rule16 Rule17 Rule18 Rule19 Rule20 Rule21 Rule22 ARAR Figure 6 1 Rules setting page On the left side of the page a Rule Manager table will appear at the top of the page More detailed information for Rule Manager will follow Under the Rule Manager table the list of rule contains four items Enable No Edit Status Rule STAR E cit E E Edit Rule3 Edi Rule4 E Rules Fdit Figure 6 2 Enable rules edit rules and status display http wise icpdas com 76 ICP DAS WISE User Manual Enable A checkbox appears before each rule check the checkbox to enable the rule and this rule will be executed after being downloaded otherwise it will only be stored temporarily No Indicates the identification number of the rule To avoid possible error it is recommended to assign the identification number in sequence Edit Click the Edit button to edit detail logic content of the rule Status OK indicates this rule is successfully defined Error indicates there is error occurs Please note if you make modification in IO
69. ge 6 1 2 DI DI channel value from XW Board or I 7000 module can be used as evaluation criteria for IF condition statement the editing page for DI Condition Setting is shown as below DI Condition Setting Module amp Channel Channel 0 Channel Value Figure 6 5 DI condition setting page Follow the following steps 1 Specify the module and channel from the dropdown list of the Module amp Channel section that you are going to include its value in the IF condition statements 11 Define the evaluation criteria of the status in IF statement to be OFF ON ON to OFF OFF to ON or Change Once the DI channel value matches the evaluation criteria the result of this condition evaluation will be true Please note If the statement involves state transitions ON to OFF OFF to ON and Change the action will be executed only once and only at the moment when the state transition occurs i Click Save button to save the settings This popup window will be closed and return to the Rule settings page 6 1 3 DI Counter DI counter value from XW Board or I 7000 module can be used as http wise icpdas com 80 ICP DAS WISE User Manual evaluation criteria for IF condition statement the editing page for DI Counter Condition Setting is shown as follow DI Counter Condition Setting Module amp Channel Channel 1 Value Figure 6 6 DI Counter condit
70. gurations 5 1 Internal Register Setting WISE provides 48 Internal Registers they can be used to hold temporary variables and to read write data via Modbus address The configuration page is shown as follow http wise icpdas com 54 ICP DAS WISE User Manual Internal Register Setting Page No 07 m No 08 m Vo prenom mn vs E No 1 E No 11 No 12 E No 13 Initial value E No 19 E No 16 Vs pere ell CL E No 27 No 31 Me iil E No 33 No 34 n ma No 37 EDGE ea KANNI TOE No 17 E No 18 No 41 DEEE Figure 5 1 Internal Register setting page The settings are as following steps LOUE A checkbox appears in front of each Internal Register check the checkbox to enable the
71. h http wise icpdas com 17 ICP DAS WISE User Manual iv Click on the I 7000 module to bring up the Configuration Window and setup the parameters such as Address Baudrate Checksum for the module The Configuration Window will be shown as follow I 7017Z as an example 4 Configuration for 70172 Module Yersion B209 Configuration Setting Channel Enable Disable Setting Protocok DEON CHO ff poo foc tom Pf tree fp Forma forme r a Baudrate 115700 gt J CH2 FFE pooo oc 150m TCH Checksum Disab CHS PFFF ponaos OC FER NN y CHA all Dataformat 7 Complement a 000 OO OC 150 nn po Filter Setting GOH v Unt FFFF pooo oos OC 7 150 mi A Mod v CHE frao ey COUR NT y sila Normal Mode v CH FFE 000008 C1 7 150mv PH Pf Parity Option None PantylN 5 1 v CHE ooo foot FEES F7 Setting Exit v CH3 fono 00000 foci d NPP Command Response Delay Time ERIA e ae all ine Select All Clear All Setting Set All as CH Differential Single Ended Delay Time o 0 30 ms Figure 2 8 l 7000 module configuration window Please note The following parameters has to be accurate to connect with WISE 580x properly Communication Protocol has to be set as DCON Address the address has to be set between 1 16 please note the configuration of I 7000 module address on WISE 580x has to be set exactly the same Baudrate the Baudrate has to be set the same as the Baudrate of WI
72. h on the controller ccc cece ec eececescececcececcececcscecesceceses 14 Figure 2 1 Figure 2 2 Figure 2 3 Figure 2 4 Figure 2 5 Figure 2 6 Figure 2 7 Figure 2 8 Figure 3 1 Figure 3 2 Figure 3 3 Figure 3 4 Figure 3 5 Figure 3 6 List of Figures WISE 380x System ATCNRITeCTUr ennemie 9 WISE 580x IO module support list 11 Select Search function on MiniOS7 Utility cc cccccceeeeeeeeeeeees 14 IP Setting button On MiniOS7 Scan 15 Network SEINE S PASS atic suaeetiacrinuneuieatiuneutaeiuinaeuiea 15 I 7000 module connection via RS 485 line 2 0 eecccccceeeeeeeeeeeeeeeeees 16 Check COM port Baudrate and DCON Protocol settings 17 7000mMmOdUIS SAC nn en EA EE 17 I 7000 module configuration window 18 Main page of the Logic Setting page cc eeecccccccccceeesseseeeceeeeeeeaeeeeees 19 Login page of the Logic Setting page cc eeseeseeccececeeeeseeeeeeeeeeeeeeas 20 After login the Logic Setting page 20 WISE 580x Logic Setting Operation Procedures cccccceceeeeeeeeeeees 21 The Channel Monitoring page before login ccccceesseeeeeeeeeeeeeees 22 The Channel Monitoring page after login ccceecccccccceeeeeeeeeeeeeeeeeens 22 Figure 3 7 Login into the Channel Monitoring page as Administrator 0000000een 23 Figure 3 8 Login into the Channel Monitoring page as Guest ccccccessseeeeeeeees 2
73. ic rules execution triggered by SMS etc Active I O Sending function New In addition to the Modbus TCP RTU Slave function that enables SCADA software or HMI device to poll the I O channels value of the WISE controller now WISE 580x provide the new function Active I O Sending for user Based on the Active I O Sending function WISE 580x can send the I O channels value of the controller actively to SCADA software or HMI device by event trigger I O channel value changed or periodic cycle This function will improve the efficient of the data communication between WISE 580x and SCADA software or HMI device Please note The SCADA software or HMI device must equip the Modbus TCP Slave function to receive the I O channels data sent by WISE 580x http wise icpdas com 12 ICP DAS WISE User Manual This document is intended to give you a full range instruction to WISE 580x controllers You will be able to learn how to edit logic of the rules and how to download the rules to the controllers for conditional execution http wise icpdas com 13 ICP DAS WISE User Manual 2 Before Connection Before connecting to WISE 580x Web HMI pages please complete the following steps to implement network configuration and I 7000 modules parameter settings The procedures are as follow 2 1 Network configuration Please make sure the Init Switch on the controller has been switched to OFF position Connect the c
74. ill return to the rule setting page 6 2 2 DO You can execute an action in DO channel of XW Board or I 7000 module in the THEN ELSE Action statement the editing page for DO Action 1s shown as follow DO Action Setting Channel Value Figure 6 18 DO action setting page Follow the following steps i Select the DO channel from the dropdown list of channel field in the Module amp Channel section 11 Specify the output value of DO Channel from the dropdown list of the Channel Value field The output value can be OFF ON or Pulse Output Pulse Output applies to XW Board only For I 7088 belongs to PWM Pulse width modulation modules the DO channel Action will be Start PWM or Stop PWM i Click Save button to save the settings The popup window will http wise icpdas com 9 ICP DAS WISE User Manual be closed and return to the Rule settings page 6 2 3 DI Counter You can reset DI counter in the THEN ELSE Action statement the editing page for DI counter Action is shown as follow Di Counter Action Setting Module amp Channel Channel 0 Save Figure 6 19 DI Counter action setting page Follow the following steps 1 Select the DI channel to reset DI counter from the dropdown list of channel field in the Module amp Channel section 1 Click Save button to save the settings The popup window will be closed and return to the Rule settings pag
75. ing Page The detailed information of the parameters are as follow http wise icpdas com Please refer to section 4 7 for detailed information of the Address Name Polling Timeout and Timeout Retry Interval fields Data Model WISE 580x offers 4 Data Model selections to match the Modbus RTU Slave module configuration Please refer to the section 4 7 1 for detailed information In this case please select Holding Register 4x Start Address Allows to set up the starting address of Holding Register 4x on the Modbus RTU Slave module you would like to retrieve Continuous Data Number After finishing the Start Address setting specify the Continuous Data Number it is the number of Holding Register data you would like to retrieve from the Start Address Data Type WISE 580x support 6 kinds of data type setting for Holding Register data of Modbus RTU Slave module The 6 Data Type options are 16 bit Signed Integer 16 bit Unsigned Integer 16 bit Hex 32 bit Signed Long 32 bit Unsigned Long and 32 bit Floating Point If the 16 bit HEX option is selected please input the HEX max min values and the Real max min values for linear transformation 51 ICP DAS WISE User Manual MIN 0000__ MAX FFFF HEX Data Real 0 me After finishing the Start Address Continuous Data Number and Data Type setting click on Add button A
76. ing steps 1 Select Enable Data Logger to enable the data logger function 11 In the File Name field input the data log file name This name has to be in English the length is limited to 8 characters 111 The Data Format field allows to edit data format and content The I O channel drop down lists help for easy editing data log content http wise icpdas com 64 ICP DAS WISE User Manual iV VI Vil format Following is examples for data log content coding the following coding indicates I 7000 module Address 1 AI4 I 7000 module Address 4 DI5 I 7000 module Address 2 DO4 Smiaid Sm4di5 Sm2do4 Data Format Module 7005 2 Ch 4 M In the data log file current date time and data log type Period recording or Event trigger recording will also be automatically pasted to each data log item The final data log content format will be like this 20110501 12 35 00 XXXX P Date and time of User input data Specify the data log is the Data Log item log content Period recording P or string Event trigger recording E Select Sampling Period to enable period recording function in WISE When the time reaches the period time interval the data will be recorded once in pre set data format The data recording will keep going periodically There are ten options 10 secs 30 secs 1 min 2 mins 3 mins 5 mins 10 min 20 min 30 min 1 hour In the Close Log File field
77. inistrator You can directly enter specific values to output channel data Ch 0 Ch 1 Switch 1 Ch 2 Switch 2 Ch 3 Switch 3 Ch 4 Switch 5 Ch 6 Switch 4 ch 5 Switch 6 Ch 7 Switch 7 Switch amp oS TA n Ed All Minkte Mena reel Figure 3 7 Login into the Channel Monitoring page as Administrator The following figure shows the interface when login as a Guest The Guest can only view the channel data without the permission to modify the data DO Ch 0 Ch 1 Switch 1 Switch 2 E ON E ON Ch 2 Ch 3 Switch 3 Switch 4 E ON E ON Ch 6 Ch 7 Switch 7 Switch amp OFF OFF Go to Logic Setting ng e ICP DAS Co Lid All Rights Reserved Figure 3 8 Login into the Channel Monitoring page as Guest http wise icpdas com 23 ICP DAS WISE User Manual 4 Basic Setting Under the Basic Setting section you can set up Name Setting Time Setting Ethernet Setting Password Setting XW Board Setting I 7000 Module Setting and Modbus RTU Module Setting 4 1 Name Setting Name Setting page is for you to give your controller a name for easy recognition and identification Name Setting page is shown as follow Figure 4 1 Name Setting page If you have already given a name to this controller when you get on this page the name you previously set up will be shown on the page After you modify or input the name click Save to save the change The na
78. ion setting page Follow the following steps 1 Specify the module and channel from the dropdown list of the Module amp Channel section that you are going to include its value in the IF condition statements 11 Set up the expression statement for this counter value Select an 99 99 299 99 99 66 operator from gt lt gt lt or Change If the operator 6699 99099 99 299 99 99 1S gt lt gt or lt an evaluation value has to be specified if the DI counter value match the evaluation criteria the result of this condition evaluation will be true If the operator is Change the condition will be true when there is a change to the counter value The action will be executed only once and only at the moment when DI Counter experience a change i Click Save button to save the settings This popup window will be closed and return to the Rule settings page 6 1 4 Discrete Input Discrete Input value from Modbus RTU module can be used as evaluation criteria for IF condition statement the editing page for Discrete Input Condition Setting is shown as below Discrete Input Condition Setting Module amp Address Address 10 M Address Value Figure 6 7 Discrete Input condition setting page http wise icpdas com g1 ICP DAS WISE User Manual Follow the following steps 1 Specify the module and address from the dropdown list of the Module a
79. is value to make sure every Modbus RTU Slave device connected to the WISE 580x has enough time to http wise icpdas com 40 ICP DAS WISE User Manual 111 iV VI Vil process the Modbus command or shorten this value to improve the efficient of the poll mechanism between Modbus RTU Slave device and WISE 580x Select the address of the Modbus RTU Slave module The address has to be set between 17 20 Please note the configuration of the address must be the same as the Modbus RTU Slave module address setting In the Name field input the Modbus RTU Slave module name This name will be used in IF THEN ELSE rule edition Input the Polling Timeout field The Polling Timeout indicates the time interval for WISE 580x to send command to the Modbus RTU Slave module and wait for the response the unit 1s millisecond Input the Timeout Retry Interval field The Timeout Retry Interval indicates the time interval for WISE 580x to resend command to Modbus RTU Slave module when it s in the timeout status when performing communication between WISE 580x and Modbus RTU Slave module The unit is second After finish the settings of Baudrate COM2 Silent Interval Address Name Polling Timeout and Timeout Retry Interval click Add button The new Modbus RTU Slave module will be added to the module list An example module list is shown as bellow Please note a WISE 580x can connec
80. l be displayed on the Channel Status page You can set the initial value of the AO channel in the Power On Value field WISE 580x will output this value for the AO channel when is power on The default initial value is 0 After all AO channel settings are completed click Save button to save the changes http wise icpdas com 33 ICP DAS WISE User Manual 4 6 l 7000 Modules Setting I 7000 Modules Setting page allows you to select the module types of the I 7000 modules and DL 100T485 connecting to the WISE 580x via COM2 and enables to set up the configuration for each individual I 7000 module Each WISE 580x controller allows to connecting to up to 16 I 7000 modules Module Address setting must be in the range 1 16 The I 7000 Modules Setting page is shown as below l 7000 Module Setting Page Baudrate COM2 9600 y bps Checksum O Enable Disable Auto Search Type Address Polling Timeout 300 milliseconds D raarss saute or 00 m AO Ping menu Figure 4 14 l 7000 module setting page Follow the following steps In the Baudrate field select the WISE 580x COM2 data transmission rate from the drop down list In the Checksum field specify the Checksum setting for the communicate between WISE and I 7000 to be enabled or disabled The default setting is Disable In the Auto Search field click on Scan button to search the I 7000 modules that are connected to
81. l into Register type 69 Figure 5 15 Attribute of Active I O Data Sending cceccccccceeeeeeeeeeeeeeeeeeees 70 Figure 5 16 SMS Command Data Retrieve Coding Rules ci eesseeeeeeeeeeees 71 Fisur 5 17 SIMS Sette PAR nissan ii instant firent Miiirsates 73 Figure 5 18 SMS Quick Command Setting Page cccsssssseeecececeeaeeeseseeeeees 74 Preure Ol Rules setine PAS in sn ind taiccslivac duennniee 76 Figure 6 2 Enable rules edit rules and status display 76 Pistite 623 5 Ru le seting Dae rss den arent Nes ne ate a Nas sn TT Figure 6 4 All Condition seting pafe rerereoneassn aeaa a 78 Figure 6 5 DI condition setting page RS NN ANR 80 Figure 6 6 DI Counter condition setting page sssseeeesssssssseeeressssssseceresssssseeeeeees 81 Figure 6 7 Discrete Input condition setting page 81 Figure 6 8 Coil Output condition setting Page cc ceeecccccccccccesseeeeeeceeeeeeaeesseeeeeees 82 Figure 6 9 Input Register condition setting page 83 http wise icpdas com 6 ICP DAS WISE User Manual Figure 6 10 Holding Register condition setting page 83 Figure 6 11 Internal register condition setting Page sesssssoeeesssssssseerressssssssserees 84 Figure 6 12 Timer condition setting page 85 Figure 6 13 Schedule condition setting page 86 Figure 6 14 Rule Status condition setting page cccccccccccccccsssseeeeeceeeceeeaeeeseeeeeees 87 Fiere 6 15 SMS
82. le Swap swap Figure 6 37 Rule Swap setting page http wise icpdas com 104 ICP DAS WISE User Manual 7 Download to Module When there is a change being made on the Control Logic Setting page such as add new logic or modify the settings the Download to Module button on the right upper corner will change to orange color to remind you to press the button to download the rules to the module the changes will take effect only after being downloaded to the module as shown below 1 Basic Setting 2 Advanced Setting 3 Rules Setting Channel Status Upload from Module Download to Module Please download the setting to module before you leave Figure 7 1 Remind the user to press the Download to Module Click the Download to Module button to download the settings when the download process is finished the popup window will notify you the saving process 1s completed The download process is completed 100 Figure 7 2 Message showing a successful download Click Reboot button to complete the process and reboot the WISE controller Now WISE will start to run the rules that have been downloaded At this time you can still edit or modify the content of the rules http wise icpdas com 105 ICP DAS WISE User Manual 8 Upload from Module Upload from Module button allows you to retrieve Rules Setting information from the hardware devices and edit them at this Rules Setting page Click
83. led time to the control center for further administration management or data analysis Ethernet RS 232 for Serial HMI RS 485 for 7000 Series and Modbus RTU Slave Devices Temperature Analog O Measurement Digital VO Relay Output Modbus RTU Module Module Module Module Slave Device had 0101001 1222 x t aps y r Digital Pulse Frequency RTD Sensor Thermometer Relay Output ON OFF Switch Warning Light Figure 1 1 WISE 580x System Architecture http wise icpdas com 9 ICP DAS WISE User Manual WISE 580x system features IF THEN ELSE logic rules execution ability WISE 580x equips with an IF THEN ELSE logic Rule Engine it offers up to 36 IF THEN ELSE rules for you to set up the logic content After completing rule edition and downloading rules to the WISE controller the Rule Engine will loop execute the rules in order under specific conditions No programming is required to implement logic content on controllers WISE 580x provides user friendly Web UI pages for editing control logic on the controllers It enables to implement logic edition by a few clicks on the mouse to set up and deploy logic rules without writing a single line of code No extra software tool is required all operations can be done through the Web browsers Provides Web based HMI interface runs on regular Web browsers To edit control logic it only requires a browser to connect to the Web server on WISE 580x No extra software to
84. llowing figure shows an example of the data arrangement of the I O Data Table for the Register Merge Coil into Register type Coil and Register Register Merge Coil into Register 1 Local Address 123 Coil 6 Register 2 aix IR Figure 5 14 The I O Data Table for Register Merge Coil into Register type IV Enable the Active sending of I O Data Table then WISE 580x will actively send all the I O Data Table s channels data to the SCADA software http wise icpdas com 69 ICP DAS WISE User Manual Active sending of I O Data Table Attributes of Active I O Data sending Receiver NetID 1 Range 1 255 say 300 milliseconds Range 1 65535 Timing to send out I O When an I O change take place Data Every seconds Figure 5 15 Attribute of Active I O Data Sending It is required to set the Receiver s SCADA software IP address the Modbus TCP Slave s Port number and NetID of the Receiver s the Timeout value and the type of Timing to send out I O Data There are two options for the Timing to send out I O Data one option is to send out the data when an I O channel value change takes place the other is to send out the data at periodic time schedule 5 9 SMS Setting WISE 5801 offers SMS alarm message sending and SMS command receiving functions For SMS alarm message sending function WISE 5801 offers up to 1
85. load all files saved at that day at a scheduled time The upload time can be set from the dropdown list IX After all Data Logger settings are completed click Save button to save the changes Please note 1 The micro SD card will be formatted automatically when it is inserted into WISE 580x at the first time 2 The data logger files inside the micro SD card will be stored by month When the micro SD card s free space is less than 20 WISE 580x will delete the old log files and only keeps the data logger files of the last month Please don t keep any file other than the data logger files in the micro SD card These files will also be deleted by the system according to this rule 5 8 Active I O Setting WISE 580x equips the Active I O sending function There are two parts in this function I O Data Table Configuration and Active sending of I O Data Table Even though WISE 580x allows to connect with up to 16 I 7000 I O modules and 4 Modbus RTU Slave I O modules at the same time however the channel data of each I O module that WISE 580x received is located in the different Modbus Address memory block of WISE 580x Therefore when using SCADA software to retrieve the data the SCADA software must poll each I O module s channel data separately It is impossible to poll all WISE 580x I O module s channels data at one time In order to improve the efficient of the data communication between WISE 580x and SCA
86. low schedule Action Setting Figure 6 24 Schedule action setting page Follow the following steps i Select the pre defined Schedule from the dropdown list of the Index field Please note the Schedule you select has to be enabled in Advanced Setting 11 Specify you want to Enable or Disable this schedule when this THEN ELSE Action statement is executed ii Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 2 9 Email You can send a message to an Email group when executing a THEN ELSE Action statement the editing page is as below Email Action Setting Email Information 1st Receiver Email Address Robert hotmail com 2nd Receiver Email Address Subject Temperature Report Temperature is too high 3rd Receiver Email Address Figure 6 25 Email action setting page Follow the following steps http wise icpdas com 96 ICP DAS WISE User Manual 1 Select the pre set Email group from the dropdown list of the Index field Please note the Email you select has to be enabled in Advanced Setting The Email group information will be displayed for you to verify if this is the Email group you are going to send the message to 1 Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 2 10 CGI You can send a CGI Command to a Remote Server device whe
87. lows to modify output channel and Internal Register data by SMS command Each SMS command message allows to modify one output channel or Internal Register value Specify the output channel or Internal Register by the coding rules as described above add a at the end of the string and then add the data value you would like to change to For DO input 0 or 1 O indicates OFF and 1 indicates ON For AO input the value in floating point format Modify SMS command variable data WISE 5801 offers up to 12 SMS command variables The status of the variables can be set as O or 1 The status of SMS command variable can be included in IF Condition as part of logic rules You can send a SMS command message to modify the status of the variable and then perform the execution of an Action that has been previously set http wise icpdas com 71 ICP DAS WISE User Manual 3 types of SMS command examples are given as follow SMS Command Types Retrieve real time channel data Modify channel data Modify SMS command variable data The SMS Command which user sends GET xdi0 m1ai2 n18ro03 Inquires the value of DIO on XW Board the value of AI channel 2 on I 7000 that locates at address 1 and the value of Holding Register address 18 on Modbus RTU device that locates at address 3 SET m2a01 2 5 Modify the value on AO channel 1 on the I 7024 that locates at address 2 the value is modified to be 2 5 ACT 2 1
88. mand List field Now you can send the SMS Quick command string DATA shown as the Quick Command List in the figure above to WISE 5801 after WISE 5801 receiving the DATA command it will execute its original command GET m1di0 m1dil m1di2 m2ai0 m3ao0 irl to retrieve the DIO DI1 DI2 channel values of I O module Address 1 the AIO channel value of I O module Address 2 the AOO channel value of I O module Address 3 and the IRO Internal Register 0 value and then will send back all the values to you For SET and ACT SMS Command there are two options for SMS Quick Command edition The first option is as the second listed Quick Command on the Quick Command List shown as figure above The AO quick command replaces the original command SET m3a00 2 3 when WISE 5801 receive the SMS http wise icpdas com 74 ICP DAS WISE User Manual iV VI Vil Vill Quick command AO it will set the AO channel O of the I O module Address 3 to be 2 3 The second option is to edit the SMS Quick command AO to be SET m3a00 as the SMS Original command string In this format when use the AO Quick command it is required to append a value to the Quick command string such as AO 2 3 WISE 5801 will set the AO channel 0 of the I O module Address 3 to be 2 3 In this way the output channel value can be modified flexibly as any other values by sending command like AO
89. me you input will appear on the top of the page as shown below Please note the Save button on Name Setting page is for temporary storage only to complete the Name Setting and save the change to the controller please finish the process of Download to Module Name Room 1 1 Basic Setting 2 Advanced Setting 3 Rules Setting QY _ Web Inside Smart Engine N Dy Web Anywhere Automation Anywhere Channel Status Upload from Module Download to Mod J Figure 4 2 The Name location on WISE Web Page 4 2 Time Setting Time Setting is for setting up time on WISE controller It also allows to set up Time Synchronization to sync the clock through network with SNTP Time Server The following figure illustrates the set up interface http wise icpdas com IA ICP DAS WISE User Manual Time Setting Page Year 2011 Month 6 Day8 Ml e me 7 M Time Synchronization SNTP Time Server nn time windows com IP or Domain Name Figure 4 3 Time setting page On every entry you make this page will display current date and time that are read from the hardware device clock You can remotely modify the date time of the hardware device clock here After you finish modification click Save to save all changes to the hardware devices WISE 580x also has the ability to sync the clock to an SNTP time server for time synchronization through the network The Time Synchronization Setting is shown as follow 1
90. mp Address section that you are going to include its value in the IF condition statements 1 Define the evaluation criteria of the status in IF statement to be OFF or ON Once the Discrete Input value matches the evaluation criteria the result of this condition evaluation will be true i Click Save button to save the settings This popup window will be closed and return to the Rule settings page 6 1 5 Coil Output Coil Output value from Modbus RTU module can be used as evaluation criteria for IF condition statement the editing page for Coil Output Condition Setting is shown as below Coil Output Condition Setting Module amp Address Address 2 Address Value Figure 6 8 Coil Output condition setting page Follow the following steps 1 Specify the module and address from the dropdown list of the Module amp Address section that you are going to include its value in the IF condition statements 1 Define the evaluation criteria of the status in IF statement to be OFF or ON Once the Coil Output value matches the evaluation criteria the result of this condition evaluation will be true i Click Save button to save the settings This popup window will be closed and return to the Rule settings page 6 1 6 Input Register Input Register value from Modbus RTU module can be included in the http wise icpdas com g2 ICP DAS WISE User Manual IF condition stat
91. n executing a THEN ELSE Action statement the editing page is shown as below Figure 6 26 CGI Command action setting page Follow the following steps 1 Select the pre set CGI Command action from the dropdown list of the Index field Please note the CGI Command Index you select has to be enabled in Advanced Setting 1 Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 2 11 Recipe You can execute a Recipe action in THEN ELSE Action statement the editing page for Recipe Action is shown as follow Recipe Action Setting hee Figure 6 27 Recipe action setting page http wise icpdas com 97 ICP DAS WISE User Manual Follow the following steps 1 Select the pre set Recipe action from the dropdown list of the Index field Please note the Recipe Index you select has to be enabled in Advanced Setting 1 Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 2 12 Rule Status The Rule Status can be modified to be Disable or Enable in the Action The editing page for Rule Status Action Setting is shown as below Save Figure 6 28 Rule Status action setting page Follow the following steps 1 Specify the index number of the Rule It has to be a previously saved Rule that is going to be changed in the Action Condition statement from the dropdown list of the
92. n 2 2 Setup Welcome to the WISE Firmware Uploader version 2 2 Setup Wizard This wizard will guide you through the installation of WISE Firmware Uploader version 2 2 It is recommended that vou close all other applications before starting Setup This will make it possible to update relevant system Files without having to reboot your computer WARNING Before you install backup you customized Files because they will be overwritten Click Next to continue Figure 10 1 Install WISE Firmware Uploader Choose the installation location to install WISE Firmware Uploader Click Install to start the installation WISE Firmware Uploader version 2 2 Setup Hak Choose Install Location Setup will install WISE Firmware Uploader version 2 2 in the Following Folder To install in a different Folder click Browse and select another Folder Click Install to start the installation Destination Folder CODLCPOASUVISE Firmware Uploader Space required 677 0KE Space available 4GE WISE Firmware Uploader Installer built on 2011 12 16 at FF 02 44 49 Figure 10 2 Select installation directory The installation progress will be shown as below please wait till the installation is completed E WISE Fumware Uploader version 2 2 setup Eo x Installing Please wait while WISE Firmware Uploader version 2 2 is being installed Create shortcut C Documents and Settings nving Lee BAS THEME ICPOAS W
93. n 2 2 is not running Click Next bo continue Cancel Figure 10 6 Uninstall WISE Firmware Uploader 1 http wise icpdas com 110 ICP DAS WISE User Manual Click Uninstall to uninstall the program A WISE Firmware Uploader Uninstall Uninstall WISE Firmware Uploader version 2 2 Remove WISE Firmware Uploader version 2 2 From your computer WISE Firmware Uploader version 2 2 will be uninstalled From the Following folder Click Uninstall to start the uninstallation Uninstalling From CICPDASWISE Firmware Uploader WISE Firmware Uploader Installer built on 2011 12 16 at TF G2 44 49 Figure 10 7 Uninstall WISE Firmware Uploader 2 When the uninstall process is completed click Finish to finish the process A WISE Firmware Uploader Uninstall Completing the WISE Firmware Uploader version 2 2 Uninstall WISE Firmware Uploader version 2 2 has been uninstalled From your computer Click Finish to close this wizard Cancel Figure 10 8 Complete uninstalling WISE Firmware Uploader 10 3 Update WISE firmware Please follow the seven steps below to update the WISE firmware program on the hardware devices i Before update Please visit WISE product web site http wise icpdas com or contact ICP DAS service to obtain the latest version of the http wise icpdas com 111 ICP DAS WISE User Manual WISE 580x firmware program Copy the file to the computer that
94. n list of the Index field Period field is required for each timer please input the period interval in units of seconds Specify the initial status of each timer from the dropdown list of the Initial Status field Select Start indicates the timer will start to count as soon as the hardware device is power up Stop indicates the Timer will remain off when the hardware device is power up it will not be activated until being triggered under certain conditions The default setting of initial Status 1s Stop Repeat steps 11 iv After all timer settings are completed click Save button to save the changes 5 3 Schedule Setting WISE provides 12 groups of Schedules to setup prescheduled routine tasks The status of Schedule function can be In Range or Out of Range they can be included in the IF Condition statements The Action of Schedule can be Enable or Disable Please note if the Schedule is disabled the status will be Out of Range Schedule setting page is shown as below http wise icpdas com 56 ICP DAS WISE User Manual Schedule Setting Page Schedule Amount Initial Status Stop Clear All o MarkAI In Range Weekday HM Oui of Range Figure 5 3 Schedule setting page Follow the following steps 1 Select the total number of schedule you are going to use from the dropdown list of the Schedule Amount field 11 Specify the sch
95. nes 24 TE SE CORRE Re ec dat ou 24 4 3 Commum ation Settings termes 26 Ak Password Sc UNS nr Mb nat en MR ee 2 4 5 PW BO ard SENG cecce eat 28 AO POO Modules Semn is srecess4 5 Den SAT un ces 34 4 7 Modbus RTU Modules Setting ss 39 RC ANC eC CUM ocr de a en et ssa 54 5 1 Infernal ResiSterS CUMS ss ide midi 54 Digs SOU Og hea n en Seared Ds a heres 59 5 3 Sched le SCT G vice deandcradssneseadlenernaacestabediendsaadaneteadianeueadmatebediandeamancaees 56 SA EMSC N Oe ne ne a dd arr treat 59 3 9 CGI Command See RON Sin een ren 61 DO RCMP SCUINS RTS RNA indo eee A RE E 62 5 7 Data LOS S60 Sen ea tee ion 64 5 8 PRCT ECO Se UMC ons aie ne a ds ana en ail 66 5 9 SMS TE LA EU wumlupiautas wd canshalad inva nun taesautaty 70 RICE CHAR DR db inna herent 76 6 1 IF Condos ae rence nee ee 78 0 2 THENELSE ACUO SRE nd ae non mea 89 6 3 SUMMI NY OL Th ROIS nn enr ester 101 OG RUGMINI O RE Me teat mentee E 102 Download UO MOQUE in ns ane 105 Upload Tont MOMIE D ate Aare Mec ln ane 106 Channel Sason SR RS Re d dah Gadd etre 107 Firmware CDG ates ice ide 108 IOA GLE 07018 3 HO ES ne ee ta ee ee te 108 10 2 Install Uninstall WISE Firmware Uploader 108 http wise icpdas com 3 ICP DAS WISE User Manual 10 3 Update WISE firmware Appendix I Modbus Address Table Appendix II Reset to Factory Default Setting http wise icpdas com ICP DAS WISE User Manual Figure 1 1 Figure 1 2 The Init Switc
96. new Holding Register address block will be added to the Modbus address mapping table shown as below All added blocks will be located in Sequences staring from the Starting Address Please note The address number on the first column WISE 580x Local Address means the local Modbus address of WISE 580x to keep the retrieved Holding Register data The following is an example about Holding Input Register setting for a Modbus RTU Slave module The starting Modbus address of the Holding Register block is 40060 40000 60 is requires to set 2 continuous Holding Register data in the setting and the data type is 32 bit Floating Point So that the WISE 580x can access the 40060 and 40062 Holding Register address of the module and these retrieved Holding Register data will be kept in WISE 580x Modbus Address 40780 and 40782 Modbus RTU Module Setting ee Red Coil Output Discrete Input Input Register Holding Register Address 0x 1x 3x 4x Address Type 32 bit Floating Point Expand All Collapse All Figure 4 29 Modbus RTU Slave Module Holding Register Setting Example http wise icpdas com 52 ICP DAS WISE User Manual http wise icpdas com Please note If the Data Type is set as 16 bit HEX the retrieved HEX data from Modbus RTU Slave module would be transformed to floating point automatically and these transformed data can be used in IF THEN ELSE rule setting To modif
97. ng for Input Register of Modbus RTU Slave module The 6 Data Type options are 16 bit Signed Integer 16 bit Unsigned Integer 48 ICP DAS WISE User Manual http wise icpdas com 16 bit Hex 32 bit Signed Long 32 bit Unsigned Long and 32 bit Floating Point If the 16 bit HEX option is selected please input the HEX max min values and the Real max min values for linear transformation MIN MAX HEX Mino MAX 100 After finishing the Start Address Continuous Data Number and Data Type setting click on Add button A new Input Register address block will be added to the Modbus address mapping table shown as below All added address blocks will be located in sequences staring from the Starting Address Please note The address number on the first column WISE 580x Local Address means the local Modbus address of WISE 580x to keep the retrieved Input Register data The following is an example about Input Register setting for a Modbus RTU Slave module The starting Modbus address of the Input Register block is 30010 30000 10 it requires to set 3 continuous Input Register data in the setting and the data type is 32 bit Floating Point So that the WISE 580x can access the 30010 30012 and 30014 Input Register address of the module and these retrieved Input Register data will be kept in WISE 580x Modbus Address 30780 30782 and 30784 49 ICP DAS
98. ng the Start Address and Continuous Data Number setting click on Add button A new Coil Output address block will be added to the Modbus address mapping table shown as below All added address blocks will be located in sequences staring from the Starting Address Please note The address number on the first column WISE 580x Local Address means the local Modbus address of WISE 580x to keep the retrieved Coil Output data The following is an example about Coil Output setting for a Modbus RTU Slave module The starting Modbus address of the Coil Output block is 00050 00000 50 it requires to set 4 continuous Coil Output data in the setting So that the WISE 580x can access the 00050 00051 00052 and 00053 Coil Output address of the module and these retrieved Coil Output data will be kept in WISE 580x Modbus Address 00780 00781 00782 and 00783 Modbus RTU Module Setting Data Model Coil Output 0x x Start Address Continuous Data Number ipee Coil Output Discrete Input Input Register Holding Register Address on i iii reer Expand AL _Colapse Al Figure 4 23 Modbus RTU Slave Module Coil Output Setting Example 44 ICP DAS WISE User Manual To modify the starting address or quantity setting please move the cursor to the setting the function buttons such as Edit or Remove will appear Click Edit or Remove for modification dep sie Coil Output Discrete
99. odbus RTU Slave Module Coil Output Setting Page ee 43 Figure 4 23 Modbus RTU Slave Module Coil Output Setting Example 44 Figure 4 24 Modbus RTU Slave Module Discrete Input Setting Page 45 Figure 4 25 Modbus RTU Slave Module Discrete Input Setting Example 47 Figure 4 26 Modbus RTU Slave Module Input Register Setting Page 48 Figure 4 27 Modbus RTU Slave Module Input Register Setting Example 50 Figure 4 28 Modbus RTU Slave Module Holding Register Setting Page 0000 51 Figure 4 29 Modbus RTU Slave Module Holding Register Setting Example 52 Figure 5 1 Internal Register setting page ss 55 Figure 522 mer setne ACC rea E E 56 Fiere asde Schedule SEIS pat Gacr ree a E E tue 57 Figure 5 4 Schedule Calendar setting page nsossssooenessssssssoerrsssssssseceresssssssseerees 58 Fis re 3 3 Email setg Das ee nes Lane ns tn 59 Figure 5 6 Email encoded string setting ss 60 Figure 5 7 CGI Command setting page soeeeesssssssoeersssssssscteressssssseererssssssseeeeees 6l Figure 3 9 ReCIDE sectio Dae moni denim aoa 62 Figure 5 9 Recipe Action Management ss 62 Figure 5 10 Data Loster setuno pate cenin E rondes 64 Preure 3 Ti 5 Act vel SENE DAS nn a in E E a 67 Figure 5 12 I O Data Table configuration UT 67 Figure 5 13 The I O Data Table for Coil and Register type 68 Figure 5 14 The I O Data Table for Register Merge Coi
100. ol installation is needed on the target PC Support XW Board and I 7000 I O Module WISE 580x allows to connecting with a wide range of the XW Board and I 7000 Remote I O modules that enables to find best solutions to meet the requirements Please refer to the following table for I O modules and functions more to come in near future P Rincon Modes Voltage amp Current I 7012 I 7017 Thermocouple I 7011 I 7018 I 7019 RTD I 7013 I 7015 I 7033 AI AO Analog Output I 7021 I 7022 I 7024 I 7000 DC Digital Input I 7041 I 7051 I 7052 I 7053 Remote AC Digital Input I 7058 I 7059 I O Module DI DO DC Digital Output 1 7042 I 7043 I 7045 DC Digital Input amp Output 1 7044 I 7050 I 7055 Power Relay Output I 7060 I 7061 I 7063 I 7065 I 7067 Relay Solid State Relay Output I 7063A B I 7065A B Output Photomos Relay Output I 7066 Others Counter Frequency I 7080 I 7088 http wise icpdas com 10 ICP DAS WISE User Manual DL Series Temperature and Humidity DL 100T485 new DI DO XW 107 XW 110 XW Board DI DO AI AO Available Soon XW 304 XW 310 Figure 1 2 WISE 580x 10 module support list Support Modbus RTU Slave Module In addition to XW Board and I 7000 I O modules WISE 580x also allows to connect with devices that support Modbus RTU Slave protocol for I O monitoring The ability to connect with Modbus RTU Slave devices enables flexibility and scalability for system implementation and
101. ontroller to power supply and to the network The Init Switch position is shown as below Lock Figure 2 1 The Init Switch on the controller Install and execute MiniOS7 Utility MiniOS7 Utility can be downloaded from the following link Please download version v3 2 4 or later http ftp icpdas com pub cd 8000cd napdos minios7 utility minios7_util ity On toolbar select Connection gt Search shown as below A MiniOS7 Scan window will pop up and automatically start to search controllers in the network MiniOS7 Utility Ferion 3 2 4 Ga Fie Connection ds Command Configuration T Tools x Hew connection F2 Su Last Connection Alt F2 M ame sus Ca DCOM File Folder E Data _Logaer File Folder 2C 4 EzProg l File Folder 2C O MO_104 File Folder 2C a hadi Lilith Fils Faldar 30 Figure 2 2 Select Search function on MiniOS7 Utility http wise icpdas com 14 ICP DAS WISE User Manual After finish searching find the target controller and click TCP Broadcast and then click IP Setting button on the toolbar as shown below FR MiniOS Scan Figure 2 3 IP Setting button on MiniOS7 Scan Click IP Setting button a network settings window will pop up Input the information and click the Set button to complete the settings IP Setting 5j Ed Recommend Settings IF 192 169 100 211 Mask 255 255 256 0 Gateway 1 92 169 100 254 Alia
102. ou specified can t be overlapped If you specify an end time that is earlier than the start time such as 20 00 00 06 00 00 it indicates the end time will be set one day after the start date On the calendars click to toggle highlight on the dates you d like to execute or not execute the operations for this Schedule If the date shows a yellow background it indicates the date is In Range that is that date falls into the range that will execute the operations On the contrary if the date shows a red background it indicates that date is Out of Range that is that date falls out of the range and will not execute the operations By default all dates will be In Range that is during the date range you select the operation will be executed every day Clear All button is used to reset all dates to be In Range http wise icpdas com 58 ICP DAS WISE User Manual whereas Mark All button is for marking all dates to be Out of Range The Weekday button is for you to select all Mondays to Fridays to be In Range and Saturdays and Sundays to be Out of Range that is the operations will be executed during weekdays only On the contrary the Weekend button is for you to set all Saturdays and Sundays to be In Range and all Mondays to Fridays to be Out of Range that is the operations will be executed during weekends only vil Repeat steps ii vi After all schedule settings are complete
103. r I 7000 module in THEN ELSE Action statement the editing page for AO Action 1s shown as follow AO Action Setting 7024 1 Ch 0 si Figure 6 17 AO action setting page Follow the following steps i From the dropdown list of the Module amp Channel field select the AO channel index to execute actions 11 Specify the Operator in the Operator field The 3 operators are as follow Indicate assign the new AO channel value as the value in Value field Indicate assign the new AO channel value as the original AO channel value plus the value in Value field Indicate assign the new AO channel value as the original AO channel value minus the value in Value field iii In the Value field 4 sources can be used as channel value Self Defined Value assign a self defined value Module amp Channel I 7024 1 M Ch Assign Value as M 10 AI Channel value using AI channel values from XW Board or I 7000 http wise icpdas com 90 ICP DAS WISE User Manual Module amp Channel Operator Value Al l 7024 1 Ch 0 co on AO Channel value using AO channel values from XW Board or I 7000 Module amp Channel F 70240 M AO si Internal Register using value of Internal Register iv Click Save button to save the settings The popup window will be closed and w
104. rd New Password Confirm New Password Guest Password New Password Confirm New Password Figure 4 5 Password setting page WISE provide two passwords set one for Administrator the other for Guest To avoid unauthorized access and altering of data it is required to input password before you get on the WISE webpage Both default passwords set for Administrator and Guest are wise You can modify the password on this page Password length is limited to 16 characters http wise icpdas com 27 ICP DAS WISE User Manual 4 5 XW Board Setting XW Board Setting page allows you to set up the configuration of the XW Board that connects to the WISE 580x and function as I O control interface The XW Board Setting is shown as follow XW Board Setting Page Add Figure 4 6 XW Board setting page Select the XW Board you are using from the drop down list and click Add a window for setting up XW Board channel parameters will appear Complete the settings for each XW Board channel Please note i After you complete all configuration for XW Board DI DO AI and AO channels remember to click Save to save the settings 1 WISE 580x allows to connect with one XW Board only however it allows to connect I 7000 modules and Modbus RTU modules via RS 485 interface through COM2 at the same time when connecting to the XW Board 4 5 1 XW Board DI Channel Settings The XW Board DI Channel Setting
105. reset CI Rule1 Rule2 O Rule3 Figure 6 35 Rule Reset setting page Reorder Reorder existing rules Click Reorder button a window as shown below will pop up A menu will appear at the top of the page it contains a drop down list for selecting the target rule and a pair of Move Up Move Down buttons to move target rule to the desired location All rule locations will be listed in sequence currently support 36 rule locations If the rule content of a specific rule location has been previously edited Rule Content X X rule sequence index will appear If the rule content of the rule location is blank it will be specified as None To reorder a rule select the target rule from the dropdown list the corresponding Rule content X font will turn to bold black from its usual black Click on Move Up Move Down buttons to move the selected rule to the desired location and then click Save to save the settings Rule Reorder Rule12 Figure 6 36 Rule Reorder setting page http wise icpdas com 103 ICP DAS WISE User Manual Swap Exchange the Rule content of a pair of rules Click Swap button a window as shown below will pop up From the left side drop down list select the first rule has to be previously edited and select the second rule from the right side drop down list the rule content can be blank click Save to swap the rule content Ru
106. ress 1 AI channel 0 as an example Module amp Channel ch The Module amp Channel section of DL 100T485 1s shown as below select a channel from Humidity Temperature C and Temperature F Module amp Channel DL 100 1 Ch Humidity ve 11 Set up the expression statement for this channel value Select an 6699 990 99 99 299 99 operator from D i And then specify the evaluation value If this AI channel value match the evaluation criteria the result of this condition evaluation will be true You can compare the AI channel value with the following 3 values for condition evaluation Self Defined value Giving a self defined value to compare with the AI channel value Module amp Channel 7005 1 M Ch ee Value as Channel value Using AI channel values from other modules XW Board or I 7000 to compare with the AI channel value Module amp Channel Operator g Al 7005 1 m2 2 1 7005 1 M Ch 2 m f 7017 2 Ch 1 M http wise icpdas com 79 ICP DAS WISE User Manual Internal Register Using the internal register value to compare with the AI channel value Module amp Channel Operator Value Internal Register M iv Click Save button to save the settings The popup window will 7005 1 M Ch be closed and return to the Rule settings pa
107. ress information for different modules XW107 Parameter Name Modbus Length Data Range Address Type Coil Output Unit Coil 8 Bits DO Ch 5 0 OFF 1 ON DO Ch 6 0 OFF 1 ON DO Ch 7 0 OFF 1 ON Discrete Input Unit Discrete Input 8 Bits DI Ch 0 10020 0 OFF 1 ON DI Ch 1 0 0FF 1 0N DI Ch 2 0 0FF 1 ON DI Ch 3 0 0FF 1 0N DI Ch 4 0 OFF 1 ON DI Ch 5 0 OFF 1 ON DI Ch 6 0 0FF 1 ON DI Ch 7 l 0 0FF 1 ON Input Register Unit Register 16 Bits DI Counter 0 1 DI Counter 1 DI Counter 2 DI Counter 3 DI Counter 4 DI Counter 5 a 0 65535 0 65535 0 65535 0 65535 0 65535 0 65535 t t I I I z t t t I I n n n n n n I http wise icpdas com 118 ICP DAS WISE User Manual XWII0 Parameter Name Modbus Length Data FES Discrete Input Unit Discrete Input 8 Bits DI Ch 0 10020 DI Ch 10 DICh 11 DI Ch 12 DI Ch 13 DI Ch 14 DI Ch 15 Input Register Unit Register 16 Bits DI Counter 0 DI Counter 1 DI Counter 2 DI Counter 3 DI Counter 4 DI Counter 5 DI Counter 6 DI Counter 7 DI Counter 8 DI Counter 9 DI Counter 10 DI Counter 11 DI Counter 12 http wise icpdas com t t t I I I I Int t I I Int I z t I I zz I I t n n n n n n nt n n n n n n z 0 65535 0 65535 Range O OFF 1 ON O OFF I ON O OFF I ON O OFF 1 ON O OFF I ON O OFF 1 ON O OFF I ON O OFF I ON O OFF I ON O OFF I ON O OFF 1 ON O
108. rt the SMS command receiving function In the Authorized Phone Number field input the phone numbers you would like to authorize to send SMS commands to WISE 5801 Please note the Authorized Phone Number has to be input in the format Country code area code and number For example if the Authorized Phone Number is a cell phone number 0987654321 in Taiwan area please input the Authorized Phone Number as 886987654321 http wise icpdas com 73 ICP DAS WISE User Manual 111 To use the SMS Quick command edition function please click the Setting button in the Quick Command field then a SMS Quick Command Setting Page will pop up as follow SMS Quick Command Setting lt GET M OES UEC Module XW107 w i v Ch 0 Quick Command List Quick Command Original Command DATA GET m1di0 m1di1 m1di2 m2ai0 m3ao0 ir1 O O AO SET m3a00 2 3 Rule1 ACT 1 1 L Remove Figure 5 18 SMS Quick Command Setting Page Input a simple self defined command string in the Quick Command field and then edit the original SMS command by selecting the command type and I O channel from the dropdown list shown as figure above in the Original Command field Press Add button after finishing the SMS command setting the SMS Quick command and its corresponding SMS Original Command will be shown in the Quick Com
109. rver login ID in the Login ID field vi Enter the SMTP server password in the Password field vii Enter the sender s name in the Sender Name field vili Enter the sender s email address in the Sender Email Address field t th e 1 5 Receiver Email ix Enter the receiver s email address in the address field Please note you can input up to 5 receivers at least one email address has to be entered Please enter the email address in sequence to avoid possible error x Enter the email subject in the Subject field xi Enter the content in the Content field The length of the content cannot exceed 160 characters In addition Email provides an encoded string for you to add current channel value into Email content You can use the I O channel selection interface shown as below to add channel value encoded string into the Email content Device temperature report Device1 s temperature is m2ai6 It is too high Please be careful about jim Content Note The length of the message cannot exceed 160 characters Insert Real Time Variable Module 7017 2 M Chi6 m Figure 5 6 Email encoded string setting http wise icpdas com 60 ICP DAS WISE User Manual xii Repeat steps 11 xi After all email groups settings are completed click Save button to save the changes Please note WISE 580x Email sending function can only work with the SMTP Email ser
110. s WISE 5900 DHCP T Figure 2 4 Network Settings page After finish Network settings reboot the WISE 580x controller for the changes to take effect http wise icpdas com 15 ICP DAS WISE User Manual 2 2 l 7000 Module Parameter Settings To access I O data on I 7000 Modules it is required to complete I 7000 module parameter settings before trying to communicate with I 7000 Modules The I 7000 module parameter settings can be done by DCON Utility You can download DCON Utility from the link below http ftp 1cpdas com pub cd 8000cd napdos driver dcon_utility And you can download DCON Utility manual from the link below http ftp 1cpdas com pub cd 8000cd napdos driver dcon_utility manual Install the DCON Utility on PC and connect the I 7000 Module to the PC for parameter settings please follow the steps below for more detailed information please refer to DCON Utility manual i Connect the I 7000 modules to the PC with DCON Utility installed via RS 485 line make sure the RS 485 line is properly connected For PC to receive RS 485 signals a RS 232 to RS 485 or a USB to RS 485 converter is required For more converter information please refer to ICP DAS converter product page http www icpdas com tw product solutions industrial_ communic ation converter converter selection html Figure 2 5 l 7000 module connection via RS 485 line http wise icpdas com 16 ICP DAS WISE User Manual 11
111. s will affect the data update rate for the Modbus RTU Slave module Please minimize the number of Modbus address setting blocks merge the conjunctive setting blocks to speed up the data update rate for the communication between WISE 580x and Modbus RTU Slave module 4 7 1 Modbus RTU Slave Module Coil Output Setting The Modbus RTU Slave module Coil Output Setting page 1s shown as follow Modbus RTU Module Setting Polling Timeout milliseconds Timeout Retry Interval 5 seconds Data Model Add Figure 4 22 Modbus RTU Slave Module Coil Output Setting Page The detailed information of the parameters are as follow Please refer to section 4 7 for detailed information of the Address Name Polling Timeout and Timeout Retry Interval fields Data Model WISE 580x offers 4 Data Model selections to match the Modbus RTU Slave module configuration The Data Model list is as follow In this case please select Coil Output Ox The Modbus Address of Data Model Modbus RTU Slave Modules http wise icpdas com 43 ICP DAS WISE User Manual http wise icpdas com Start Address Allows to set up the starting address of Coil Output Ox on the Modbus RTU Slave module you would like to retrieve Continuous Data Number After finishing the Start Address setting specify the Continuous Data Number it is the number of Coil Output data you would like to retrieve from the Start Address After finishi
112. setting 1 7000 Module XW Board or Modbus RTU Slave module or in Advanced Setting after finish defining the rules it might cause unexpected error due to the changes some variables may no longer exist Therefore in case you make any modification please double check your settings and Rules definition to make sure no errors are present Click the Edit button the Rules Setting page will appear Le r a ee ee an oy None None nes SL Figure 6 3 Rule setting page The rule number will be displayed at the top of the page The Description field provides a space for you to make a brief description of this Rule An IF THEN ELSE Rule setting table appears under the description section Each Rule offer 3 IF conditions You could create IF condition statements by selecting appropriate operator AND OR from the dropdown list In order to avoid possible errors the design of this table is foolproof You are required to finish setting up Condition before moving on Condition2 and so on Each Rule also offers 3 THEN actions and 3 ELSE actions More detailed information will follow http wise icpdas com 77 ICP DAS WISE User Manual 6 1 IF Condition In IF Condition statement the following values or their status can be included as evaluation criteria 606040040000 0 Al DI
113. t DiCoumer12 301524N 1 m 0 65535 0 65535 0 65535 Int Int Int Int Int Int Int Int Int nt 1 7080 2 Counter Frequency 2 DO channel Parameter Name Modbus Length Data Type Range Address Coil Output Unit Coil 8 Bits http wise icpdas com 127 ICP DAS WISE User Manual DO Ch 0 00140 N DO Ch 1 00141 N Input Register Unit Register 16 Bits DI Counter 0 30140 N DI Counter 1 30142 N 1 7088 8 DI 8 PWM Output channel Modbus Parameter Name Address Data Type 0 0 4294967295 4294967295 Range Coil Output Unit Coil 8 Bits PWM Output Ch 0 00140 N PWM Output Ch 1 00141 N PWM Output Ch 2 00142 N PWM Output Ch 3 00143 N PWM Output Ch 4 00144 N PWM Output Ch 5 00145 N PWM Output Ch 6 00146 N PWM Output Ch 7 00147 N Discrete Input Unit Discrete Input 8 Bits DI Ch 0 DI Ch 1 DI Ch 2 DI Ch 3 DI Ch 4 DI Ch 5 10140 N 10141 N 10142 N 10143 N 10144 N 10145 N DI Ch 6 10146 N DI Ch 7 10147 N l Byte Byte Byte Byte Byte Byte Byte Byte O OFF I ON O OFF 1 ON O OFF 1 ON O OFF 1 ON O OFF I ON O OFF I ON O OFF I ON O OFF I ON Byte Byte Byte Byte Byte Byte Byte Byte O OFF 1 ON O OFF I ON O OFF 1 ON O OFF 1 ON O OFF 1 ON O OFF I ON O OFF I ON O OFF I ON Input Register Unit Register 16 Bits 30140 N 2 http wise icpdas com DWORD DWORD DWORD DWORD DWORD DWORD DWO
114. t to 4 Modbus RTU Slave modules at most http wise icpdas com 4 ICP DAS WISE User Manual Vill 1X Modbus RTU Module Setting Page Baudrate COM2 19600 bps Silent Interval 48 milliseconds Polling Timeout Ga 1 10000 Timeout Retry Interval 5 seconds Range 3 65535 Modbus RTU Module List of COM2 Address Polling Timeout o Co Co B EE Figure 4 21 Modbus RTU Slave Module List Click on the Modbus RTU Slave module on the module list and click Setting button to get in to the Coil Output Discrete Input Input Register and Holding Register setting page to edit settings To remove the Modbus RTU Slave module select the module you would like to remove and click Remove button To relocate Modbus RTU Slave to other address click Move Up or Move Down to move the Modbus RTU Slave module to desired address location After all Modbus RTU Slave module settings are completed click Save button to save the changes Please refer to the following sections for more detailed information of Coil Output Discrete Input Input Register and Holding Register configurations on Modbus RTU Slave module Please note i Currently WISE 580x only allows to connect with Modbus RTU Slave module via COM2 Please make sure the Modbus RTU Slave modules are connected to COM2 on WISE 580x http wise icpdas com 49 ICP DAS WISE User Manual 1 The number of Modbus address setting block
115. tatus will also be shown on this page In addition the general WISE 580x Logic Setting Web UI operating procedures will be Basic Setting Advanced Seiting displayed as follow Rules Setting Download to Module Figure 3 4 WISE 580x Logic Setting Operation Procedures Please note DO NOT refresh or close the web page when you are editing the rules otherwise the contents of all previous settings will be gone And please remember all settings will take effect only when they have been downloaded to modules if you close the web page before finishing Download to Module all settings will be disappeared as well In addition there is a language selection menu on the left region of the main page WISE Web UI offers 3 languages English Traditional Chinese and Simplified Chinese for you to choose your preferred languages The system will memorize previous language selection and will automatically switch to the previously chosen language next time when connected to the WISE Web UI Please note do not change the language setting during the process of rule edition otherwise the previous edited content might disappear It is recommended to perform language selection at the beginning when connected to the Logic Setting page or after finishing Download to Module http wise icpdas com 21 ICP DAS WISE User Manual 3 2 Channel Monitoring Page When you connect to WISE 580x controller by cell phone it will automatically being
116. the new Holding Register address value as the original Holding Register address value plus the value in Value field Indicate assign the new Holding Register address value as the original Holding Register address value minus the value in Value field i In the Value field giving a self defined value iv Click Save button to save the settings The popup window will be closed and will return to the rule setting page 6 2 6 Internal Register You can modify the value of Internal Register in the THEN ELSE Action statement the editing page for Internal Register Action Setting http wise icpdas com 93 ICP DAS WISE User Manual is Shown as below Internal Register Action Setting maes O operator vawe i Figure 6 22 Internal Register action setting page Follow the following steps 1 Select the pre defined Internal Register from the dropdown list of the Index field Please note the Internal Register you select has to be enabled in Advanced Setting 11 Specify the Operator in the Operator field The 3 operators are as follow Indicate assign the new Internal Register value as the value in Value field i Indicate assign the new Internal Register value as the original Internal Register value plus the value in Value field Indicate assign the new Internal Register value as the original Internal Register value minus the
117. tion turns to be FALSE Vi All selected Actions will be listed on the Recipe page Click on the radio checkbox to select the target Action you can edit the selected Action by click on Edit button or delete the Action from the list by click on Delete button To rearrange the order of the Action click the Move Up or Move Down button to move the target Action to the desired order To delete all Actions click on the Clear All button to remove all actions from the list Vil Repeat steps 11 vi After all Recipe settings are completed click Save button to save the changes http wise icpdas com 63 ICP DAS WISE User Manual 5 Data Logger Setting WISE 580x offers one set of Data Logger function that allows system to record I O channel data in Data Log file at a scheduled time or under specific condition In addition it also allows to send the Data Log files by FTP or Email The Data Log file is in CSV format The following figure illustrates the configuration interface Enable Data Logger Data Format Module 1 7005 2 po__ v Ch 4 m Aaa Enable 5 mins M Sampling Period Close Log File Every hour s Log File Sending Attribute eman imde Send as attachment when the log file is closed tee aee oo aa Ce o EAD eooo aomas Password FTP FTPPath BR os O Log file is closed Every day at o clock Figure 5 10 Data Logger setting page Time to Upload Follow the follow
118. value in Value field iii In the Value field 4 sources can be used as value Self Defined Value assign a self defined value index Operator Assign Value as ce ee AI Channel value using AI channel values from XW Board or I 7000 M Al a 70176 Ch 1 AO Channel value using AO channel values from XW Board or I 7000 http wise icpdas com 94 ICP DAS WISE User Manual iv Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 2 7 Timer You can change the Timer status to Start or to Reset the Timer in the THEN ELSE Action statement the editing page for Timer Action Setting is shown as below Timer Action Setting Figure 6 23 Timer action setting page Follow the following steps i Select the pre defined Timer from the dropdown list of the Index field Please note the Timer you select has to be enabled in Advanced Setting 11 Specify you want to Reset or Start this Timer when this THEN ELSE Action statement is executed i Click Save button to save the settings The popup window will be closed and return to the Rule settings page 6 2 8 Schedule You can change the Schedule status to Enable or to Disable the http wise icpdas com 95 ICP DAS WISE User Manual Schedule in the THEN ELSE Action statement the editing page for Schedule Action Setting is shown as be
119. ver that uses port 25 and must be without SSL cryptographic protocols A self hosted SMTP server is recommended for Email sending function or use Yahoo account for free Email service The SMTP server for Yahoo service is smtp mail yahoo com 5 5 CGI Command Setting WISE offers up to 12 sets of CGI Command setting This function allows sending pre input CGI Command to pre set Remote Server device under certain conditions The configuration page is shown as below CGI Command Setting Page Figure 5 7 CGl Command setting page Follow the following steps 1 Specify the numbers of CGI Commands you want to set up from the dropdown list of the CGI Amount field 11 Specify the CGI group number from the dropdown list of the Index field 111 Enter the Remote Server IP Port number and CGI Command in the CGI Command field IV Enter the number in the Retry Count field It means the retry number WISE will try when it can t connect with Remote Server device V Enter the number in the Retry Interval field It means the time interval between each retry connection The unit is Second http wise icpdas com 61 ICP DAS WISE User Manual Vi Repeat steps 11 v After all CGI groups settings are completed click Save button to save the changes 5 6 Recipe Setting WISE offers up to 12 sets of Recipe setting A sequence of actions can be stored and saved in a Recipe you can setup to ex
120. y the starting address or quantity setting please move the cursor to the setting the function buttons such as Edit or Remove will appear Click Edit or Remove for modification pepe pes Coil ae ans airs Input Register Holding Register 3x 1 I Address 32 bit Floating Point After all Holding Register settings of the Modbus RTU Slave module are completed click Save button to save the changes 53 ICP DAS WISE User Manual 5 Advanced Setting Advanced Setting provides additional features and allows you to perform more setting on hardware devices Click the Advanced Setting button a column of buttons will appear on the left of the page Internal Register Setting Timer Setting Schedule Setting Email Setting CGI Setting Recipe Setting Data Logger Setting Active I O Setting OMS Setting Apply to WISE 5801 only R A A A A a A A G Please note In order to avoid possible error when performing rule definition IF THEN ELSE please always finish configuration in Advanced Setting before starting to define Rules Avoid unnecessary change in Advanced Setting after you finish rule definition Unexpected errors might occur if you violate this sequence Advanced Setting gt Rule Setting In case you make any modification please double check your settings and Rules definition to make sure no errors are present The following sections will describe more detailed information for these confi
121. you previously installed WISE Firmware Uploader Connect the WISE 580x the one you are going to update WISE firmware to the network Please verify and make a note of the WISE 580x IP address you will need it later in the process ll Execute WISE Firmware Uploader Taking Windows XP as an example click Start gt All Programs ICPDAS WISE and then click WISE Firmware Uploader under the WISE category to start the program VY Paint E ee EFview EZvrEw FA Accessories HI er Startup amp Internet Explorer FA PISO PS400 All Programs B QG ICPDAS Lag OFF C m sian Br WISE Firmware Uploa t Da FT WISE Firmware Uploader FA PISO PS4o0 FA ET M8194H Figure 10 9 Launch WISE Firmware Uploader iii Select WISE module type Select the WISE module type from the dropdown list Make sure the module type is WISE 580x as shown in the following figure WISE Firmware Uploader version 2 2 IP Address PO Upload Firmware About WISE Figure 10 10 Select the WISE module type iv Set up Module IP Enter the IP address of the module that you are going to update WISE firmware as shown in the following figure http wise icpdas com 112 ICP DAS WISE User Manual WISE Finmware Uploader version 2 2 Sele Module Type WISE 580x b 192 168 100 212 Upload Firmware About WISE Figure 10 11 Assign IP address v Select WISE firmware file