User Manual for WireXpert WX4500 (Fiber Testing)
Contents
1. MPO Light Source Adapter MPO Type A Tail Cords MPO Cleaning Kit WX AD MPO LS WX AC MPO CORD AUP WX AC CKIT MPO MPO Power Meter Adapter MPO Type A Reference Cord WX AD MPO PM WX AC MPO CORD AUU MPO Type B Reference Cord WX AC MPO CORD BUU Type A Connector WX AC CONNECTOR SCSC Optional EF Compliant Kit WX AD MPOEF KIT available www psiberdata com Psiber Data WireXpert User Manual Key differences between WX4500 and WX500 Feature WX4500 WX500 Frequency of measurement 2500 MHz 500 MHz Accuracy Specification Level V Level 2G Level IV Fiber Testing option Yes Class FA CAT 8 options Yes Patch Cord Test adapters Yes www psiberdata com EI Psiber Data WireXpert User Manual WireXpert Overview Power ON OFF button Touch sensitive color LCD screen USB device port Audio port USB host connector for flash drive RJ 45 Ethernet port for remote control Power supply port 12V One Touch access buttons Brightness control button Navigation scroll buttons Context sensitive Help button Probe interface connector Battery compartment ITA O Functionality Power ON OFF Button Powers on or shuts down the device Press and hold for 5 seconds to power on device Press and hold for 2 seconds to shut down device Turns red when charging USB device port Enables remote connection to the PC for firmware o Audio port Enables vocal communicatio
2. All test adapters are designed to fit onto every WireXpert units The device automatically detects adapters when connected and configures its interface to the matching parameters and limits Adapter Configuration Warnings WireXpert will display a warning a potential conflict is detected between the adapter and the test settings It is important to use the appropriate adapters as accuracy of measurements will be affected Cabling Certification and Tests Certification testing with WireXpert is highly intuitive and simple The autotest function performs a series of measurements between the Local and Remote devices and analyses the results to determine if the cabling run passes or fails the selected standards Fiber Optic Certification Testing One of the most crucial step when installing a fiber optic network is testing the newly installed and terminated fiber optic cables ensuring they are functioning properly The two basic categories in which typical indoor fiber optic cables are tested e Continuity A good unbroken fiber cable is able to transmit the necessary data i e a broken or imperfect fiber within a cable causing the far end to be not visibly lit there will be interruption to data transmission This can be tested using the Visual Fault Locator VFL e End to End Optical Loss Optical Loss is the difference between the emitting optical power that is sent into a cable s transmitting end and the actual amount that is
3. Psiber Data WireXpert For Fiber Testing User Manual User Guide WireXpert v6 2 6 for Fiber Testing 0 Last updated on 01 Dec 2014 Copyrights 2014 Psiber Data Pte Ltd www psiberdata com M Psiber Data WireXpert User Manual WX Series WX4500 Wire pert www psiberdata com NS Psiber Data WireXpert User Manual Notices No part of this manual may be reproduced in any form or by any means including electronic storage and retrieval or translation into a foreign language without prior agreement and written consent from Psiber Data as governed by international copyright Laws Warranty The material contained in this document is provided as is and is subject to being changed without notice in future editions Further to the maximum extent permitted by applicable law disclaims all warranties either express or implied with regard to this manual and any information contained herein including but not limited to the implied warranties of merchantability and fitness for a particular purpose Psiber Data shall not be liable for errors or for incidental or consequential damages in connection with the furnishing use or performance of this document or of any information contained herein Should Psiber Data and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these Terms the warranty terms in the separate agreement shall c
4. gt Start Software Upgrade gt ER i Load Custom Limits gt a gt Load Cable Labels for List Based Test gt 5 Launch eXport software 6 Go to File gt Create New Project to create new project space 7 Goto Import gt USB Flash Drive and select the flash drive Click Import 8 Select database and click Import Selected to import or click Import All for all databases www psiberdata com Psiber Data WireXpert User Manual Tools Help Languages Cable Label Open Project 7s Save Project Close Project Recent Exit Import Export Settings Tools Help Languages DOB Ob i j Jj Reference Psiber PRX files Organize v New folder Photos Name Presentations Pull Out Banne Reference Fluke JDSU Nordic Psiber List Based 1 PRX files Sample Tes y lt File na New Project prx Save as type Test Project File prx X AlienCrossTalk prx X Demo prx X Elements Holdings prx X fail prx x fiber prx X Franklin prx X Great City Mall prx X Project Hospital prx X with AXT prx Hide Folders www psiberdata com v CO Search PRX files Date modified 4 4 10 1 23 10 4 10 4 10 4 10 16 09 4 10 07 AM 14 4 41 PM 14 4 34 PM 25 08 14 10 47 AM 14 11 50 AM 14 10 07 AM 14 10 02 AM 14 10 01 AM 14 2 14 PM
5. s global presence ensures our customers receives sales and technical support anywhere around the world Americas Canada Softing North America 29 Water Street Suite 301 Newburyport MA 01950 Phone 1 978 499 965 Email wirexpert softing com Asia Pacific Psiber Data Pte Ltd 3 Science Park Drive 03 09 The Franklin Singapore Science Park 1 Singapore 118223 Phone 65 6569 6019 Fax 65 6899 1016 Email wireXpert psiberdata com Europe Psiber Data GmbH Germany Munich Lise Meitner Str 3 82152 Krailling Phone 49 89 89136060 Fax 49 89 89136066 E mail info psiber data com Psiber Data Ltd United Kingdom Faygate Unit 14 New House Business Centre Old Crawley Road Faygate West Sussex RH12 4RU Phone 44 0 1293 852306 Fax 44 0 1293 852298 E mail info psiber data co uk www psiberdata com ES Psiber Data China China Shanghai Room 208 Building 1 No 388 Tianlin Road Xuhui District 200233 Shanghai China Email chinasales psiberdata com Psiber Italy Via Gaslini 20052 Monza MI Phone 39 039 2844287 Fax 39 039 2844286 E mail info psiber it Psiber Data France France Paris Phone 33 660 970910 E mail infofr psiber data com
6. The fundamental philosophy behind the WireXpert User Interface is simplicity in its ease of use The main functions of the One Touch access buttons as follows www psiberdata com Psiber Data WireXpert User Manual AUTOTEST The AUTOTEST button will perform an immediate certification test on the last configured settings If no settings were configured default settings will be used Test results will be generated automatically after the test is completed AUTOTEST You will receive any of the following 3 results after the AUTOTEST e Green PASS Good test result in accordance to pre defined settings e Green PASS Marginal pass result with some disturbance Acceptable results e Red FAIL Unacceptable results with sever disturbance on one or more test parameters e Red FAIL unacceptable results with slight disturbance on one or more test parameters You will be given the option to View a more detailed result or Cancel test result If Detailed test results is chosen additional test parameters will be displayed and plot will be generated when parameter is chosen If Cancel is chosen you will be prompted to Save the test result or continue with Cancel An AUTOTEST will fail in the event of missing connection at the near end Local or far end Remote or wrong settings configured 7 November 2014 11 28 7 November 2014 11 28 7 November 2014 11
7. 27 Fiber 1 Fiber 1 Fiber 1 2 2 ft Fiber 2 2 2 ft Fiber 2 Limit Settings Limit Settings TIA 568 3 TIA 568 3 A Connections 0 Connections 0 0 Splices 0 f Splices 1310nm Fiber 1 Fiber 2 1550nm Fiber 1 Fiber 2 2 2 ft Fiber 2 Limit Settings TIA 568 3 Connections 0 0 A Splices f 1310nm Margin vf 1550nm Margin Loss 0 25 dB 0 25 dB Loss 0 17 dB 0 17 dB Limit 1 50 dB 1 50 dB Limit 1 50 dB 1 50 dB vf Length Of Fiber Margin 1 25 dB 1 25 dB Margin 1 33 dB 1 33 dB Refractive Index AUTOTEST results for Detailed test result for Detailed test result for Single ended SMF 1310nm 1550nm www psiberdata com Psiber Data WireXpert User Manual r EZ 9997 477 8 October 2014 10 46 8 October 2014 10 45 Loss L R Margin AUTOTEST results for Dual ended MMEF 850nm Polarity gt Connection Map Type Channels Abs Power dBm Loss dB OD O NO OH amp amp NHN a h ad gt C J AUTOTEST results for MPO Polarity using Type A OM3 cord Local Rx Channel Remote Tx Channel Loss L R Loss R L Detailed test result for 1300nm Coca ABC Auto Test PASS Connection Map Type Local Rx Channel Remote Tx Channel 9 9 9 9 GBSEGOCOOOCOO008 Fiber map The type of results will diffe
8. Dual Ended Horizontal link Cable Manufacturer 1 me F Measurement Direction Single Direction A TIA 606 A Class 2 Single building Horizontal link Type Connector Name Site Label Source Cable Manufacturer Generic MMF TIA 606 A Class 2 Single building Backbone cable Cable Name OM gt TIA 606 A Class 3 Campus Backbone cable Refractive Index 1 493 Customized hierarchical cable labels Connector Name SMLC gt it UNSPECIFIED FX Custom Cable ID s imported from PC Software Label Source Simple Labels AA Operator Operator Unspecified gt Current Label _4 Typical Fiber Test Settings MPO Test Settings None Manual input of label names is required for every saving of result Simple Auto Increment Labels Simple Label Provides simple numeric increments to a prefix www psiberdata com gp M Psiber Data WireXpert User Manual c EZ ue Simple Cable Label Label Name Label Name pnm G EIE s enm Simple Cable Label Start End Value Auto Increment Cable Label suggest the next sequential Cable Id in Testing Auto Increment Start End Value EM 999 Enter Start Value Enter End Value TIA 606 A Class 1 Single Room Horizontal Link TIA 606 A Class 1 standard labelling scheme mainly used to support labelling for a building or premises that is served in a single equipment room uc EM
9. M Psiber Data WireXpert User Manual To set reference Connect matching adapters to the Local and Remote units 2 If MPO connect only the Local adapter to the Local unit and Remote adapter to the Remote unit Connect the 2 units together using the correct cords provided in the kit Press the TOOLS button Set Reference Click next to begin set reference 9998 ERG e 59981 October 2014 10 38 8 October 2014 10 38 8 October 2014 10 38 Site UNSPECIFIED FX Probe Type Fiber MM EF i Limit TIA 568 3 H Configuration Dual Ended L R 1300nm 19 68 dBm 20 46 dBm 850nm 19 42 dBm 19 38 dBm Connect the Reference Cords as above Proceed to Set Reference Set Reference Success Set Reference for MMEF Cocal ABC 10000 Local Set Reference Abs Power dBm Abs Power Channels dBm Information MPO Set Reference In Progress Please Wait Set Reference for MME 6 Set Reference will fail in the event of e Adapter probe mismatch i e one SM and one MM adapters e Firmware version mismatch e Noconnection between Local and Remote units e Time out www psiberdata com Psiber Data WireXpert User Manual How do perform a certification test AUTOTEST Press the AUTOTEST button once settings and limits have been selected WireXpert will use the last configuration or factory settings to perform the AUTOTEST if new settings are not config
10. Settings Sleep Interval LCD Display will be switched off in Sleep mode to save power Sleep Interval minutes 10 2 Never Sleep Power Off Interval minutes 30 gt 10Minutes 49 Audio Settings gt 5 Operator Unspecified gt 5 3Minutes 5 5 Restore Default Settings 1Minute Plot Y axis Direction Auto Save Results Touch Screen Calibration I Language Settings How do I change the Auto Power off time setting Press the SETUP button System Settings Auto Power Off Interval minutes to select the idle duration before WireXpert performs an automatic shutdown 1 3 E mn em Ooo System Settings Auto Power off interval Time amp Date 10 28 43 07 27 2014 gt Length Unit Never Auto Power Off Sleep Interval minutes 30 20 Minutes 9 Audio Settings 10 Minutes gt Operator Unspecified gt m 2 5 Restore Default Settings E Plot Y axis Direction 5 Auto Save Results Touch Screen Calibration l Language Settings www psiberdata com E Psiber Data WireXpert User Manual How do I restore my WireXpert to default settings Press the SETUP button System Settings Restore Default Settings to restore WireXpert to factory settings Click YES to begin restoration CAUTION Restoring WireXpert to default settings is an irreversible action All user defi
11. Test Project File Test Project File Test Project File Test Project File Test Project File Test Project File Test Project File Test Project File est Project File 0 Connected 0 Connected Psiber Data WireXpert User Manual Export Settings Tools Help Languages Device y j Cable Label i USB Flash Drive wi From PC 3 Other Devices 0 Connected File Import Export Settings Tools Help Languages ID A H T cable Label Please choose the desired USB Flash drive you would like to i 0 Connected www psiberdata com Psiber Data WireXpert User Manual File Import Export Settings Tools Help Languages 27 H 0 d Cable Label E Please mark the desired site s you would like to import Site pw20100717 UNSPECIFIED pw20100003 UNSPECIFIED pw20100003 UNSPECIFIED FX pw20100003 NEW SITE pw20100003 DA CH PL pw20100003 DA PC PL pw20100003 DA CH CH pw20100003 PHASE DATA _ pw20201471 REGRESSION TEST 14 OCT 0 Connected File Import Export Settings Tools Help Languages DAB 0 4 1 Device Lint Margin 88 57 REGRESSION TEST 14 C Wix4500 Wx4500 Wx4500 Wix4500 Wax4500 Wix4500 Wix4500 Wx4500 Wx4500 Wx4500 TIA PatchCord Cat6 2m 68 2GHz
12. default WireXpert creates an UNSPECIFIED site for default saving if new sites are not created EZ D Site List nS TIA 568 3 gt re A m o EM m Loss Limit lt Channel Selector Remote Configuration Dual Ended Cable Manufacturer Measurement Direction Single Direction as Cable Manufacturer Generic MMF seFiber Type Cable Name oM Connector Refractive Index 1 493 Site Connector Name SMLC Reference Method One Jumper gt Site UNSPECIFIED FX T Source Label Source Simple Labels aa Operator Operator Unspecified gt m i ee ee Typical Fiber Test Settings MPO Test Settings www psiberdata com EJ A Psiber Data WireXpert User Manual New Site Name New Site Name Site Properties ede de de 9 E23 de de 0 Ud 167 1 Site Contact IZ X C V ilic space gt cer 90 How do I change the labelling scheme for saving test results Press the SETUP button Test Settings Label Source to choose from a list of scheme S Limit Loss Limit Channel Selector TIA 568 3 gt None user key in label manually gt Simple Auto Increment Labels gt Reference Method One Jumper gt TIA 606 A Class 1 Single room Remote Configuration
13. format with prefix to support infrastructure with multiple or without floors telecom rooms racks patch panels and ports positions in a single building generated using eXport software only Ideal for project managers with specified labelling format Field testers can choose which labels to test from the imported labels 1 Select or create a Site where the custom list will be used 2 Insert USB flash drive to USB port on WireXpert 3 Device will automatically detect USB flash drive 4 Select Load Cable Labels for List Based Test 5 Click YES to begin import Click the ok button to proceed 6 Press the SETUP button Cable Label Source 7 Select Custom Cable ID s Imported from PC Software 8 Select label source file and click ok to continue Da WEBI ceo USB Flash Drive Attached USB Flash Drive Attached This operation will copy all saved test records This operation will copy all saved test records from tester to USB flash drive from tester to USB flash drive H Copy Test Records to USB Flash Drive gt This USB Flash Drive Contains a New Software Version 6 1 11 s Start Software Upgrade gt Load Custom Limits gt gt Load Custom Limits gt gt Load Cable Labels for List Based Test gt gt Load Cable Labels for List Based Test gt 11 3 INS Raj USB Flash Drive Attached This operation will copy all saved test records from tester to USB flash drive z gt Load Custom Limits
14. ges Class 1 Horizontal Link A A Floor TIA 606 A Class 1 Single Room Horizontal Link Auto Increment Start End Value Start Value Floor NNI 2 End Value Floor co E o Class 1 Horizontal Link A A Telecom Room TIA 606 A Class 1 Single Room Horizontal Link Auto Increment Start End Value Start Value Telecom Room End Value Telecom Room a i3 IE omn Class 1 Horizontal Link ga Panel TIA 606 A Class 1 Single Room Horizontal Link Auto Increment Start End Value Start Value Panel h End Value Panel ic Class 1 Horizontal Link A A Port Position TIA 606 A Class 1 Single Room Horizontal Link Auto Increment Start End Value Start Value Panel Port 9999 End Value Panel Port TIA 606 A Class 2 Single Building Horizontal Link Single Building Backbone Cable TIA 606 A Class 2 standard labelling scheme mainly used to support labelling of infrastructure with one or more telecommunication spaces in a single building EZ o Class 2 Horizontal Link Floor TIA 606 A Class 2 Single Building Horizontal Link Auto Increment Start End Value Start Value Floor End Value Floor www psiberdata com BET 1 3 EIN 85 en Class 2 Horizontal Link 4 5 As Telecom Room TIA 606 A Class 2 Single Building Horizontal Link Auto Increment Start End Value Start Value Telecom Room End Value Tele
15. or any other volatile liquid to clean the device Do not permit any blockage of the ventilation holes of the device Environmental Conditions This instrument is designed for indoor use and in an area with low condensation The table below shows the general environmental requirements for this instrument Environmental conditions Requirements Operating Temperature C to 50 Operating humidity 20 to 85 RH non condensing Storage temperature 20 C to 70 Storage humidity 5 to 90 RH non condensing The WX4500 WX500 complies with the following Safety and Regulatory requirements DIN EN 55024 Edition 2003 10 IEC CISPR 24 1997 modified A1 2001 A2 2002 EN 55024 1998 A1 2001 A2 2003 DIN EN 55022 VDE 0878 22 2008 05 IEC CISPR 22 2005 modified A1 2005 EN 55022 2006 A1 2007 Regulatory Markings The CE mark is a registered trademark of the European Community This CE mark shows that the product complies with all the relevant European Legal Directives www psiberdata com ed Psiber Data WireXpert User Manual Declaration of Conformity Manufacturer s Name Psiber Data Pte Ltd Manufacturer s Address 3 Science Park Drive 03 08 The Franklin Singapore Science Park 1 Singapore 118223 Declares under sole responsibility that the product as originally delivered Model Number WireXpert WX4500 FA WX500 Description Class FA Copper Certification Kit Equipment Cable Certifier Compl
16. received at the far end This can be tested using a Light Source and a Power Meter Single Mode and Multi Mode There are two main types of fiber optic cables the Single Mode fiber SMF and the Multi Mode fiber MMF The main difference is in the size of its core with MMF having a wider 62 5 or 50 um allowing multiple modes or rays of lights to propagate and SMF having a narrow 9 um allowing only a single mode of light to propagate They carry different properties with its own advantages and disadvantages www psiberdata com gp Psiber Data WireXpert User Manual Wavelength 1310nm 1550nm 1300nm Up 30km Up to 60km Up to 3km Up to 10km eee 0 25dB km 3 5dB km 1 0dB km General Usage Telecom amp CATV Networks LAN security systems general fiber networks Encircled Flux EF Compliant Certification of MMF has been a contentious issue to the inherent uncertainties in the measurement process ISO IEC and TIA have recently adopted an Encircled Flux EF standard to characterize launch conditions to ensure certification testing can be conducted with more accurate and repeatable results Multi fiber Push On MPO The need of bandwidth continues to rise with next technologies such as 40GbE and 100GbE in line Generally used in data centres MPO provides higher density and bandwidth for 10G 40G and 100G applications which minimizes space requirements reduces air flow congestion improves cooling
17. 100m TIA 2GHz Series 6 46m 2GHz Series 6 46m COAX 2GHz 100m TIA 2GHz Series 6 46m COAX 2GHz 100m TIA 2GHz Series 6 46m COAX 2GHz 200m TIA 1GHz Series 11 100m TL og Oe oe x Overall Result Local Ser No pw20201471 Measurement Value Margin Remote Ser No pw20201472 Length m 19 Cable Manufacturer Generic UTP Delay ns 11 0 Cable Name CAT 6A UTP Cable NVP 68 Cable Type UTP Resistance Ohms 0 0 Connector Manufacturer Un Shielded Connector Insertion Loss dB 40 Connector Name UTP Mod Jack 6A Return Loss dB A Connector Type UnShielded NEXT dB 42 Limit TIA PatchCord Cat6A 2m PSNEXT dB 125 ACRF dB 6 3 Al PSACRF dB 95 Total Records 18 Selected Record No 1 0 Connected www psiberdata com Psiber Data WireXpert User Manual Device Direct connection via USB cable 1 ee Connect WireXpert to your PC using a mini USB cable Launch eXport software Go to File gt Create New Project to create new project space Go to Import gt Device Select database and click Import Selected to import or click Import All for all databases www psiberdata com EJ Psiber Data WireXpert User Manual File Import Export Settings Tools Help Languages DOoOBUdqoe x J Please mark the desired site s you would like to import PHASE DATA UN
18. 50nm Margin 147dB 2 blk flr tell rck2 p nl 3 porl Jf 1300nm Margin 131dB blk f 1r0 tell rck3 p nl 0 porl Jf Length Of Fiber blk flr tell rck3 p nl l porl blk flrO0 tell rck3 p nl 2 porl bik flr0 tel1 rck 1 pni bik flr0 tel1 rck 1 pni bik flr0 tel1 rck2 pni bik flr0 tel1 rck2 pni bik flr0 tel1 rck2 pni bik flr0 tel1 rck2 pni bik flr0 tel1 rck3 pni vv M oM bik flr0 tel1 rck3 pnl 13 Press the back or AUTOTEST button to return to the list www psiberdata com M A Psiber Data WireXpert User Manual How do export test results into eXport eXport is a data management software designed to work seamlessly with WireXpert Saved results can be exported using the following methods USB Flash Drive 1 Insert USB flash drive to USB port on WireXpert 2 Device will automatically detect flash drive 3 Select Copy Test Records to USB Flash Drive to begin copy 4 Click OK to proceed a e a a USB Flash Drive Attached Copy To USB Copy To USB This operation will copy Test results for This operation will copy Test results for both Copper and Fiber Applications both Copper and Fiber Applications from tester to USB flash drive Copying time depends on the number of Copying time depends on the number of Information This USB Flash Drive Contains a New Software 14 Test Results Copied Version 6 1 11
19. SPECIFIED FX AC COUPLE POE DEMO 0 Connected File Import Export Settings Tools Help Languages __ ______ Test Device Type Type Wx4500 bik firDtel1 1ck 1 pni 2 por1 Wx4500 bik fir0tel1 1ck2 pni O port Wx4500 bik firtel1 rck2 pni 2 port Wx4500 PRBLHAAXZA Wx4500 PRBLHAAY ZA Wx4500 PRBLHAAZZA Wx4500 A2 Wx4500 Wx4500 Wx4500 None iit c Qn amp WH Overall Result Local Ser No pw20100003 Measurement Value Margin Remote Ser No Length m 84 Cable Manufacturer Generic UTP Delay ns 428 0 Cable Name CAT 6A UTP Cable NVP 68 Cable Type UTP Resistance Ohms 15 1 Connector Manufacturer Un Shielded Connector Insertion Loss dB 0 6 Connector Name UTP Mod Jack 6A Return Loss dB 79 Connector Type UnShielded NEXT dB 32 Limit Cat 6A Channel PSNEXT dB 5 7 ACRF dB 15 2 bIk flrO tel 1 rck1 pnl O por1 PSACRF dB 16 5 Total Records 14 Selected Record No 1 0 Connected Refer User Manual eXport for more information on how to use the software www psiberdata com 41 Psiber Data WireXpert User Manual How do I change the Sleep mode setting Press the SETUP button System Settings Sleep Interval minutes to select the idle duration before WireXpert enters the sleep power saving mode Lj NIE mn es Oho System
20. ally detects which adapters are attached and selects matching test parameters Adapter Insertion Counts Every WireXpert adapter is installed with a memory chip to keep track of the number of tests performed This data ensures up to date information on the adapter s lifespan WireXpert will indicate a warning when the adapter insertion counts has expired the specified insertion counts lifespan Memory 1Giga byte internal flash memory 1Giga byte USB Flash Drive included allows for flexible test record storage www psiberdata com EJ Psiber Data WireXpert User Manual Memory Requirements The amount of memory that each test result takes up depends on the options that is configured before starting the test If plots are saved with each test file size of test results will be generally larger than one that has plots option omitted WireXpert allocates approximately 1 GB of internal flash memory for test result storage The exact amount of memory available depends on the size of the WireXpert software The maximum memory size of the USB stick is limited to 4 GB Battery Information WireXpert units are powered by Lithium lon rechargeable batteries These batteries contain circuitry that reports their state of charge to WireXpert The units can be powered by external AC DC power adapters Connecting the adapters will charge the batteries concurrently A fully charged battery can operate WireXpert for five to eight hours befor
21. as device s and probe s serial number firmware version calibration date probe type and probe test count a em a un System Settings Local Unit Time amp Date 10 28 43 07 27 2014 gt Unit SNo pw20100003 Hardware Rev 1 0 Software Ver 6 2 Calibration Date 27 April 2012 Auto Power Off interval minutes 30 gt Prise Toga Fiber MM Length Unit Meter m gt Sleep Interval minutes 10 gt gt Probe SNo PMMB 4024 Probe Test Count 196 9 Audio Settings amp Operator Unspecified gt Remote Unit 55 Restore Default Settings Unit SNo pw20100004 Plot Y axis Direction Hardware Rev 1 0 Software Ver 6 2 Calibration Date 20 December 2013 Touch Screen Calibration Probe Type Fiber MM Probe SNo PMMC 9123 L Language Settings gli Probe Test Count 103 5 Auto Save Results System Settings Device Information for SM MM MMEF www psiberdata com Site Name char 11 Records List of Test Records pr Limit Label RESULT 1 coax link 96m coax link zm coax chn 96m coax chn 2m pc tia pc iso 10 41 46 Saved test results Psiber Data WireXpert User Manual List of Sites amp Number of Records 8 Unspecified 0 Records 11 Records 0 Records Saved Sites Note Deleting a site will also delete its containing test results Requires Local and Remote Set Reference Set Reference Establish test conditions between referen
22. ce cords and cord to be tested to ensure low insertion loss using Power Meter and Light Source Requires Local and Remote SM MM MMEF Only MPO MTP Switches device to MPO mode to perform single fiber Power Meter test www psiberdata com Requires Local and Remote Power Meter Power Meter Tests for loss when paired with a Light Source Available in Local unit only Requires Local or Remote 73199 Only VFL Visual Fault Locator Emits light for visual detection of broken fiber location The DATA button provides archive and data management ability to saved sites and test results Saved test results can be renamed or deleted in this option 15 0 er List of Sites amp Number of Records a Unspecified 0 Records E char ll Records Warning This will delete selected Site and all itsTest results Deleting of Sites The TOOLS button provides advanced options for in depth troubleshooting and expert WireXpert users These options include Requires Local and Remote VUES SM MM MMEF Only Light Source Emits light source to determine loss on a Power Meter Available in Fiber Mode only Requires Local or Remote Fiber Probe Inspect Fiber Inspect Fiber Performs visual verification of fiber s quality using an external scope probe Psiber Data WireXpert User Manual Requires Re
23. cheme mainly used to support labelling for multiple buildings in a single site o Class 3 Campus Backbone Iw Tw Location 1 Building 1 Name EZ me Class 3 Campus Backbongy_ A Location 2 Building 2 Name c EE ue Class 3 Campus Backbongs 4AJA 434A 1 3 Backbone Cable Auto Increment Cable Label suggest the next sequential Cable Id Testing Auto Increment Start End Value Class 3 Campus Backbongy_ A A A Cable Auto Increment Cable Label suggest the next sequential Cable Id Testing Auto Increment Start End Value Start Value Cable Start Value Backbone Cable End Value Backbone Cables 1 Telecom Room 1 Floor 1 Telecom Room 2 Floor al End Value Cable Telecom 1 Telecom Room 2 Room Customized Hierarchical Cable Labels Customized Labels Customized labelling scheme in hierarchical format with prefix to support infrastructure with multiple floors telecom rooms racks patch panels and ports positions in a single building Field tester required to perform certification in sequential order EM amp Customized Hierarchial Cable Labels Select the fields to be included in cable label Prefix PR Building Floor Telecom Room Rack Panel Port Position www psiberdata com EJ uc EM Customized Hierarchial Cable Labels Building Floor Room Rack Panel Port Name of Buil
24. com Room B i 1 EM de Class 2 Horizontal Link Panel TIA 606 A Class 2 Single Building Horizontal Link Auto Increment Start End Value Start Value Panel ho _ End Value Panel EU Class 2 Horizontal Link A A Port Position TIA 606 A Class 2 Single Building Horizontal Link Auto Increment Start End Value Start Value Panel Port fb 9999 End Value Panel Port de Class 2 Backbone Cable d Telecom Room 1 Specify the Two Telecom Rooms between which Backbone Cables Telecom Room 1 Floor m Telecom Room 1 Name Psiber Data WireXpert User Manual Class 2 Backbone Cable A A7 Telecom Room 2 Specify the Two Telecom Rooms between which Backbone Cables Telecom Room 2 Floor E Telecom Room 2 Name uc Eae Class 2 Backbone Cable amp A A3 77 Backbone Cable Auto Increment Cable Label suggest the next sequential Cable Id Testing Auto Increment Start End Value Start Value Backbone End Value Backbone Cables gy ic Class 2 Backbone Cable A A Cable Auto Increment Cable Label v suggest the next sequential Cable Id Testing Auto Increment Start End Value Start Value Cable bo o End Value Cable TIA 606 A Class 3 Campus Backbone Cable TIA 606 A Class32 standard labelling s
25. d Connectors No of Connections Loss Per Connection dB No Of Splices Loss Per Splice dB 0 30 Cable Loss 850nm 3 5 Cable Loss 1300nm 1 5 dBiKm Press the SETUP button gt Test Settings gt Cable Manufacturer choose from list of cable manufacturers If unsure of manufacturer choose Generic MMF or Generic SMF or Customized Cable to create custom cable ae Test Settings TIA 568 3 gt gt sal Reference Method One Jumper gt Remote Configuration Dual Ended gt Measurement Direction Single Direction Cable Manufacturer Generic MMF Cable Name OM1 gt Refractive Index 1 493 Connector Name SMLC gt Site UNSPECIFIED FX Label Source Simple Labels 3 Operator Unspecified gt Cable List me 4 Cable Manufacturer Generic MMF gt Cable Name OM1 Modal Bandwidth 400 MHz km gt focal ABC Cable Manufacturers Belden Berk Tek CommScope Systimax Multimedia Connect ES ees 1 4 1 4 gt i gt gt i gt 2 3 How do I set reference between Local and Remote units It is recommended to perform a set reference measurement if the Local and Remote units are being used for the first time If there is a mismatch in firmware versions or expired calibrations WireXpert will require you to perform a set reference www psiberdata com
26. ding If you need a Separator between fields please enter below ES Building c EZ ue Customized Hierarchial Cable Labels Floor Auto Increment Cable Label suggest the next sequential Cable I Testing Auto Increment Start End Value Start Value Floor ho End Value Floor Floor Building cE Customized Hierarchial Cable Labels Room Auto Increment Cable Label suggest the next sequential Cable I Testing Auto Increment Start End Value Start Value Telecom Room End Value Telecom Room A 5 Telecom Room M Psiber Data WireXpert User Manual 5 eu Customized Hierarchial Cable Labels Auto Increment Cable Label suggest the next sequential Cable Testing Auto Increment Start End Value Start Value Rack SS z End Value Rack Telecom Rack Room 2 EIS a ez Customized Hierarchial Cable Labels Panel Auto Increment Cable Label suggest the next sequential Cable I Testing Auto Increment Start End Value Start Value Panel End Value Panel 1 3 EIE 88 ez Customized Hierarchial Cable Labels Auto Increment Cable Label suggest the next sequential Cable Testing Auto Increment Start End Value Start Value Cable End Value Cable Port Position Custom Cable ID s Imported from PC Software List Based Testing Customized labelling scheme in hierarchical
27. e requiring recharging Reducing the screen brightness and enabling the sleep function allows WireXpert to run longer on a charge WARNING Do not calibrate or operate WireXpert while the battery is hot immediately after charging If the environment is causing the temperature rise move the unit to a suitable environment Contact your nearest Technical Support centre if in doubt CAUTION Use only the supplied power supplies with the WireXpert kit Using other powers may damage the tester and void its warranty Battery Safety 1 To avoid the risk of fire burns or damage to your battery pack do not allow metal objects to touch the battery contacts 2 The battery pack is suitable for use only with compatible WireXpert devices 3 Do not disassemble the battery pack There are no user serviceable parts inside Do not dispose the battery pack in fire or water 4 Handle a damaged or leaking battery with extreme care If you come into contact with the electrolyte wash the exposed area with soap and water If the electrolyte contacts the eye flush the eye with water for 15 minutes and seek medical attention 5 Do expose the battery pack to high storage temperatures above 55 www psiberdata com M Psiber Data WireXpert User Manual 6 When discarding a battery pack contact your local waste disposal provider regarding local restrictions on the disposal or recycling of Lithium lon batteries 7 To
28. ecember 2013 Fiber MM 9123 103 How do I know if have the correct adapter for testing Press the SETUP button gt Test Settings to check the test options available to determine if the right adapter has been installed How do upgrade the firmware To upgrade WireXpert s firmware e Download and install the latest build of eXport software from psiberdata com e Export the firmware using an USB flash drive e Backup the test results in the device e Insert the flash drive to the USB port on WireXpert e Choose the upgrade firmware option and click Yes to begin upgrade www psiberdata com EJ 4 Psiber Data WireXpert User Manual USB Flash Drive Attached This operation will copy all saved test records from tester to USB flash drive Copy Test Records to USB Flash Drive gt This USB Flash Drive Contains a New Software Version 6 1 11 L Start Software Upgrade gt Load Custom Limits gt gt Load Cable Labels for List Based Test gt How do setup date and time Press the SETUP button System Settings and select the Time and Date option Time and date display format can be selected and time can be manually configured to match your local settings uos EO ue System Settings C Time amp Date 13 52 05 11 15 2013 gt Length Unit 1 3 Sleep Interval minutes Auto Power Off Interval minutes 4 9 Audio Settings amp Operator 55 Restore Defa
29. efficiency and reduces cost as compared to regular Single Mode feasible for longer links and Multi Mode require parallel optical connections fiber optics installations Depending on requirements different geometries SMF MMF 62 5um MMF 50um OM2 OM3 amp OMA and polarity management can be done with MPO www psiberdata com M A Psiber Data WireXpert User Manual WireXpert User Interface Touch Screen Layout The touch screen interface of WireXpert can be divided into three groups 1 The Information group at the top provides hardware information such as the device Information Local Remote name battery level etc 2 The Functionality group provides setting options necessary to conduct an AUTOTEST 3 The Navigation sub group provides functional settings in the functionality group T DNE Information Group zm y Test Settings Functionality Group P Loss Limit Ed Channel Selector Reference Method One Jumper sa Remote Configuration Dual Ended Cable Manufacturer Measurement Direction Single Direction p Cable Manufacturer Generic iber Type L2 Connector Name A Site E Label Source Label Source Simple Labels Operator Unspecified i Navigational Group L Operator Test Setting screen for SMF Test Setting screen for MPO MMF and MMEF The One Touch Access Buttons AUTOTEST
30. gt Load Cable Labels for List Based Test gt www psiberdata com ES Psiber Data WireXpert User Manual 1 3 IE c mn em OCO Raj ez Cable Label Source List Based Test Label Source Files None LLSXF User key in label manually Simple Auto Increment Labels TIA 606 A Class 1 Single room Horizontal link 606 Class 2 Single building Horizontal link TIA 606 A Class 2 Single building Backbone cable TIA 606 A Class 3 Campus Backbone cable Customized hierarchical cable labels gt A Custom Cable ID s Imported from PC Software Refer User Manual eXport for more information on generating list based labels 9 Press the AUTOTEST button to display the loaded cable list 10 Select label from list to begin autotest 11 WireXpert will automatically save a PASS result and return to the list or allows you to save or conduct a re test for a FAIL result manually 12 Select a tested label to view the results A tick indicates a PASS and a cross indicates a FAIL result A re test can be conducted by pressing Retest Ome Wh Maj E cz Site Name NEW SITE Site Name DEMO Fiber 1 2 bik fir0 tel1 rck1 pni MS bIk flr tel1 rck1 pni 2 blk flr tell rckl p 0 0 ft Fiber 2 nl 2 porl Q blk flr tell rckl p Limit Settings TIA 568 3 blk f 1r0 tell rck2 p nl 0 porl Connections blk flr tell rck2 p Splices nl l porl 2 2 blk flr tell rck2 p nl 2 porl f 8
31. hernet Certification kit for testing WX AD M12XCH 8 KIT Certification Kit industrial Ethernet M12 or M12 X coded channel connections WX AD VNA KIT Laboratory Setup Certification Certification kit for vector Kit network analysing WX AD SM KIT Single Mode Fiber Certification kit for testing Certification Kit 1310nm and 1550nm single mode fiber SC links Also available in LC links WX AD MM KIT VCL Multi Mode Fiber Certification Certification kit for testing 850nm Kit and 1300nm VCSEL based multi mode fiber SC links Also available in LC links WX AD MMEF KIT Encircled Flux EF Compliant Certification kit for testing EF Multi Mode Fiber Certification compliant 850nm and 1300nm Kit multi mode fiber FC links WX AD MPO KIT Multi Fiber Push On MPO Certification kit for MPO testing Certification Kit WX AD MPOEF KIT Encircled Flux EF Compliant Certification kit for EF Compliant Multi Fiber Push On MPO MPO testing Certification Kit Please contact Psiber Data for more comprehensive product offerings and catalogue www psiberdata com pete Psiber Data WireXpert User Manual Dual Control System DCS WireXpert consists of two identical devices for dual end testing and certification Both devices utilise easy to use LCD touch screen technology and graphical user interface The DCS enables quick and real time data retrieving on both ends improving efficiency and productivity significantly WireXpert Adapters
32. ies with the essential requirements of the following applicable European Directives and carries the CE marking accordingly DIN EN 55024 Edition 2003 10 IEC CISPR 24 1997 modified A1 2001 A2 2002 EN 55024 1998 A1 2001 A2 2003 DIN EN 55022 VDE 0878 22 2008 05 IEC CISPR 22 2005 modified 1 2005 EN 55022 2006 A1 2007 Valo Signature Arvind C Patel Quality Management Psiber Data Pte Ltd www psiberdata com Date December 14 2010 www psiberdata com IE Psiber Data WireXpert User Manual Contents Chapter 1 Introduction Unpacking the kits 7 Key differences between WX4500 and WX500 9 WireXpert Overview 10 WireXpert Kits 11 Dual Control System DCS 12 WireXpert Adapters 12 Adapter Configuration Warnings 12 Cabling Certification and Tests 12 Fiber Optic Certification Testing 12 Single Mode and Multi Mode 12 Encircled Flux EF Compliant 13 Multi fiber Push On MPO 13 WireXpert User Interface 14 Memory 20 Battery Information 21 Power Supply 22 Dimension 22 Environment Conditions 22 Chapter 2 Using WireXpert How do check the firmware version 23 How do I know if have the correct adapter for testing 23 How do upgrade the firmware 23 How do setup date and time 24 How do select the limit 25 How do I select the cable type for certification 25 How do set reference between the Local and Remote units 25 How do I perform a certification test AUTOTEST 26 How do I sa
33. n between Local and Remote units when connected to talkset headphones USB Host port Enables results to be exported and firmware upgrade via USB flash drive Enables loading of custom limits and labels for list based testing RJ 45 Ethernet port Enables communication between two sets of WireXpert n Power Supply port Performs charging of device when connected to power One touch access buttons Main functional buttons for WireXpert Enables quick ee teeta tng asin ce o o Context sensitive help Provides simple explanation relevant to the functionality on the current screen www psiberdata com EU M Psiber Data WireXpert User Manual Probe interface connector When connected with different probe adapters e g CAT6A channel or Permanent Link WireXpert will enable specified certification test to be conducted Battery compartment Battery storage compartment Unscrew to replace battery WX AC BATT WireXpert Kits The following kits can be ordered to perform more certification tests using WireXpert Product Number Description WX AD 6ACH KIT Copper Certification Kit Certification kit for testing WX AD 6APL KIT channel or permanent link connections up to Cat6A WX AD FACH TERA KIT Class FA Certification Kit Certification kit for testing WX AD FAPL TERA KIT channel or permanent link connections for Class FA in TERA connector Also available in GG45 connector WX AD M12CH 4 KIT Industrial Et
34. nector Name Choose from a list of connector names for more specific test parameters Site Create a new site for a new project or choose from a list of saved sites Saved sites can be deleted on this option Label Source Choose from a list of cable labelling style Operator Create or choose the operator operating the device System Settings Time amp Date Determines how time and date will be displayed Length Unit Determines Meters m or Feet ft will be used as the default length unit displayed Sleep Interval Determines the inactivity period before the LCD enters sleep power saving mode Auto Power off Interval Determines the inactivity before the device performs an auto shutdown Psiber Data WireXpert User Manual e Audio Settings Determines the volume and sound option to the device e Operator Determines the name of the operator to the device e Restore Default Settings Erases all user defined settings and reloads default factory settings e Plot Y axis Direction Determines the presentation of the Y axis on viewing detail test results e Auto Save Results If enabled WireXpert will automatically save all PASS test results with reference to the label source configured e Touch Screen Calibration Performs touch calibration to the device e Language Settings Determines the language used on the device Device Information Displays device information such
35. ned settings and stored restores will be erased and cannot be recovered 13 EIE ou em System Settings Restore Default Settings or Format Restore Default Settings or Format Time amp Date 11 26 38 11 05 2014 gt Restore Default Settings Restore Default Settings Length Unit Restore the default settings that were loaded Restore the default settings that were loaded when Unit was shipped from the factory when Unit was shipped from the factory Sleep Interval minutes Warning Below operation will erase Auto Power Off Interval minutes all current settings of this device Restore Default Settings 49 Audio Settings This operation will delete the current settings and all Test Data from this device Do you wish to continue Plot Y axis Direction ad YES no H Auto Save Results amp Operator Unspecified gt 55 Touch Screen Calibration I Language Settings How do replace an old battery The batteries are located and secured at the bottom of the WireXpert units for safety reasons To remove the batteries Switch off WireXpert and disconnect external power supplies Unscrew the battery compartment and remove the cover Remove and replace a new battery into the compartment Close fasten and secure the screw onto the compartment cover I AAA www psiberdata com EJ Psiber Data WireXpert User Manual Technical Support Psiber Data Worldwide Offices Psiber Data
36. obtain a replacement battery part number N2641A 135 contact your local dealer 8 Do charge the battery pack if the ambient temperature is above 40 C Power Supply e Removable rechargeable Li lon batteries provide more than 8 hours of continuous operation e AC power 100 240 AC plugs directly into the battery Can be recharged separate from the instrument Dimension Size 220mmH x 110mmW x 53mmD Jii e Weight approx 1 0 kg approx 2 2 165 8 pe Ns Environmental Conditions e Operating temperature OC to 40C e Storage Temperature 10C to 55C H e Relative humidity 10 to 80 eee 4 ee le lt gt qm W www psiberdata com Psiber Data WireXpert User Manual Chapter 2 Using WireXpert How do I check the firmware version Press the SETUP button Device Information to check the software version and hardware version numbers The device information page also display the last calibrated date You are reminded to recalibrate your device after one year Ls EA zn Local Unit Unit SNo Hardware Rev Software Ver Calibration Date Probe Type Probe SNo Probe Test Count Remote Unit Unit SNo Hardware Rev Software Ver Calibration Date Probe Type Probe SNo Probe Test Count pw20100003 1 0 6 2 27 April 2012 Fiber MM PMMB 4024 196 pw20100004 1 0 6 2 20 D
37. on Up gt 9 Auto Save Results Touch Screen Calibration Language Settings System Settings Select the site where the test results are saved Click ok to proceed Select result and click view to view results Select the next page if for more results G ge Data 0 Records gt List of Test Records pr Limit Label To delete a saved result 1 Pressthe DATA button 2 Select the site where the test results are saved Click ok to proceed 3 Select result and click delete to delete result www psiberdata com EJ EE List of Sites amp Number of Records EI UNSPECIFIED 14 Records 0 Records i 5 8 G g ge Site Name UNSPECIFIED 14 Records List of Test Records Limit Label b 7 Ab 2 Ab 1 None 6 6 Psiber Data WireXpert User Manual EU Geo Site Name UNSPECIFIED 14 Records List of Test Records Limit Label b 7 2 Ab 1 14 43 12 I How do I add select delete a new site 1 Press the SETUP button gt Test Settings gt Site to begin adding a new site Click the new button to add a new site Click on the empty field and enter new site name using the keypad on the screen Click OK to continue Site properties are optional but they provide additional information of the site 2E E E Click ok to save site and proceed By
38. ontrol CAUTION A CAUTION notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met Operating procedure practice if not correctly performed or adhered to could result in personal injury or death Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met General Safety Information Do not use the device if it is damaged Before you use the device inspect the casing Look for cracks or missing plastic Do not operate the device around explosive gas vapor or dust Always use the device with the cables provided Observe all markings on the device before establishing any connection Turn off the device and application system power before connecting to the 1 0 terminals When servicing the device use only the specified replacement parts Do not operate the device with the cover removed or loosened Use only the power adapter provided by the manufacturer to avoid any unexpected hazards www psiberdata com Psiber Data WireXpert User Manual CAUTION If the device is used in a manner not specified by the manufacturer the device protection may be impaired Always use dry cloth to clean the device Do not use ethyl alcohol
39. quires Local and Remote Local or Remote ZUM SM MM MMEF Only MPO Only a Switch Fiber Switches device Fiber Map Performs About Displays worldwide back to Fiber mode to perform test to determine contact information for Psiber standard tests mapping of fiber optic Data WireXpert Firmware Adapter Detection WireXpert firmware automatically detects which adapters are connected to the local and remote units and configures the testing program to match these adapters Conflicts between the installed and testing selections generate an error message Digital Fault Finding WireXpert software automatically pinpoints cable fault locations and causes speeding problem resolution and increasing operator productivity System Requirements WX 4500 provides complete certification solutions to major copper cabling and fiber optic installations Depending on requirements separate kits components or customised adapters can be purchased to provide more specialised tests and certifications For a list of available adapters please visit www psiberdata com Data Management WireXpert data management software eXport enables management of saved results such as finding renaming deleting printing and creating custom labels Please refer to User Manual eXport for more information Adapter Probe Configuration WireXpert uses different adapters to test and certify different cabling runs The device automatic
40. r depending on the Test Limits and type of cable These options include Test Settings The SETUP button provides setting options necessary to conduct an AUTOTEST e Limit Choose from alist of standards to determine the performance criteria in a given category or class www psiberdata com EO Psiber Data WireXpert User Manual www psiberdata com Length Limit SM MM MMEF only Determine the length of the fiber optic under test Loss Limit MPO only Displays the Loss Limit when Custom Limit is selected Reference Method SM MM MMEF only Choose 1 2 or 3 jumper s on single ended loopback or dual ended configuration when Set Referencing is conducted Remote Configuration SM MM MMEF only Displays the selected Set Reference configuration Measurement Direction SM MM MMEF only Choose Single or Bi directional measurements are taken when doing Autotest Channel Selector MPO only Choose which channel s to have Loss Limit included during Autotest calculations Disabled channels will be Yellow on test results Connector Manufacturer Choose from a list of connector manufacturers for more specific test parameters If unsure of manufacturer choose Generic SMF or Generic SMF for SM MM MMEF probes Cable Name SM MM MMEF only Select the cable from the selected manufacturer Refractive Index SM MM MMEF only Determines how fast light will be propagated Con
41. ult Settings E Plot Y axis Direction Auto Save Results Touch Screen Calibration l Language Settings www psiberdata com ET Time 24 hour clock 12 hour clock hh mm ss Upgrade Software This operation will load the Software from USB flash drive to this tester All Test Results in this Unit may be lost Please copy all test records to USB flash drive before upgrading Software Do you wish to continue Time amp Date Setup Time amp Date Setup 24 hour clock Time Hours Minutes Seconds hh mm ss AM hh mm ss PM Psiber Data WireXpert User Manual How do I select the limit Press the SETUP button gt Test Settings gt Limits to choose from a list of commonly used limits Three recently used limit will be on top of the list Test Settings Limit TIA 568 3 gt Length Limit gt gt Reference Method One Jumper gt Remote Configuration Dual Ended Measurement Direction Single Direction Cable Manufacturer Generic MMF Cable Name OMi gt Refractive Index 1 493 SM LC gt Connector Name 2 UNSPECIFIED FX Label Source Simple Labels 3 Operator Unspecified gt i Network Limits gt Link Validation 2 Ethernet Standard gt Fiber Channel Custom Limits How do I select the cable type for certification Indicate the Number of Connections within the Test Link excluding the En
42. ured WireXpert will display summarized result with PASS or FAIL once autotest is completed Press the view details button to view the comprehensive result 8 October 2014 10 42 s Site UNSPECIFIED FX 17 3 ft 447 3 ft Limit Settings Limit Settings TIA 568 3 TIA 568 3 Probe Type Fiber MM EF f Limit TIA 568 3 EH Configuration Dual Ended Connections 0 Connections 0 Splices 0 Splices 0 850nm Margin 0 58 dB gt f 1300nm Margin 0 75 dB Test In Progress Jf Length Of Fiber 17 3 ft Refractive Index Result for MMEF autotest Typical result screen for SM and MM Click on the wavelength to display a more comprehensive individual result Abs Power dBm Information MPO Set Reference In Progress Please Wait Result for MPO autotest Click on the different options to display a more comprehensive individual result www psiberdata com M Psiber Data WireXpert User Manual Polarity Loss Limit 1 90 dB Connection Map Type A Channels Local Rx Channel Remote Tx Channel 1 on wm amp amp N C Geeoocoooooo N 1 90 dB Loss dB 5 J How do I save view delete test results Test results can be manually saved by pressing the save button after an autotest is completed When prompted key in the record name to continue saving Simple Cable Label To change the C
43. urrent Label sequence Edit below Current Label Ab 6 gt Loss Limit 1 90 dB Channels Abs Power dBm Loss dB Save Result Saving Auto Test Result For Label Ab 6 on NO amp Bw NM JJ NL amp J Typical Fiber result screen MPO result screen If auto saving is enabled SETUP System Settings Auto Save Results test results will be automatically saved with reference to the selected Label Source SETUP gt Test Settings gt Label Source when autotest is completed www psiberdata com Psiber Data WireXpert User Manual Reference Method gt Remote Configuration TIA 568 3 gt Ld One Jumper Dual Ended gt Measurement Direction Single Direction If Cable Manufacturer Connector Name Cable Name Refractive Index Generic MMF OM1 gt 1 493 Label Source Operator SMLC gt UNSPECIFIED FX Simple Labels Unspecified i Typical Fiber Test Settings To view saved results Z8 Press the DATA button Loss Limit M Channel Selector Cable Manufacturer 2 Connector Name Site E Label Source Y Operator MPO Test Settings C Time amp Date 10 28 43 07 27 2014 gt Length Unit 49 Sleep Auto Power Off Interval minutes 4 9 Audio Settings Operator Unspecified gt 5 5 Restore Default Settings gt 7 Plot Y axis Directi
44. ve view delete test results 28 How do add select delete a site 30 How do I change the labelling scheme for saving test results 31 How do export test results into eXport 36 How do I change the Sleep mode setting 42 How do I change the Auto Power off time setting 42 How do I check if my WireXpert is running in demonstration demo mode 43 How do restore my WireXpert to default settings 43 How do I replace an old battery 43 Technical Support Psiber Data Worldwide Offices 44 www psiberdata com ET Psiber Data WireXpert User Manual Chapter 1 Getting Started Unpacking the kits Single Mode Fiber WX_AD_SM_KIT m Single Mode Adapters Single Mode Duplex Cords SC Cleaning Kit WX AD SM WX AC SM CORD SCSC WX AC CKIT SC SC Connector WX AC CONNECTOR SCSC Multi Mode Fiber WX AD MM KIT S Multi Mode Adapters Multi Mode Duplex Cords SC Cleaning Kit WX AD MM WX AC MM CORD SCSC WX AC CKIT SC Mandrels WX AC MM MANDREL SC Connector WX AC CONNECTOR SCSC www psiberdata com IE Psiber Data WireXpert User Manual Encircled Flux Compliant Multi Mode Fiber WX_AD_MMEF_KIT ww Multi Mode Adapters MMEF Reference Cords SC Cleaning Kit WX_AD_MMEF WX AC MMEF CORD FCSC WX AC CKIT SC MMEF Tail Cords WX AC MMEF SCSC SC Connector WX AC CONNECTOR SCSC Optional LC Cord Kit WX AD MMEF KIT LC available Multi fiber Push On WX AD MPO KIT