Home

AIRREX PLATE HEATER

image

Contents

1. e e m t Temperature Sensor AC 380V 3ph 50Hz ee Plate ol Far inrared Rays Plate of Far nrared Rays TERMINAL BLOCK Tilt Sensor ol Piate ol Far rrared Rays E LE Overheat Sensor HALOGEN LAMP iz AC 290 1ph 50Hz 000 Front Controller DISPLAY Power 380Va c 3ph TERMINAL BLOCK Temperature Sensor 50Hz Deo TERMINAL BLOCK o GHP rw Sensor J Ho Overneat Sensor Piate ol Far Inared Rays AC 230V 1ph 50Hz Ol amp xm 0000 Front Controller PTC HEATER Wiring diagram ALON A n AIRREX Q Specification Model no classification AH 720 AH 765 AH 780 Heating Capacity BTU h 9 200 23 900 34 500 Power Consumption kW 2 7 7 10 1 Space for use m 17 20 47 55 70 78 230Va c 50Hz 1ph or Power supply 230Va c 50Hz 1ph 380Va c 50Hz 3ph Consumption Current A MAX 11 7 MAX 30 4 10 6 MAX 44 15 3 Size mm WxLxH 540x290x800 670x290x920 970x290x920 z Product weight kg overheating safety device conductivity safety device over temperature prevention device abnorma
2. n AIRREX AIRREX PLATE HEATER Users Manual AH 720 AH 765 AH 780 SNOILNVIAYd JSN JO mod dm f N gt Thank you for purchasing Airrex Plate Heater Please read the instructions thoroughly before using your heater gt After reading the instructions please keep them in a place accessible to all users gt Ensure you read Safety Precautions in advance and use the product correctly gt The product is specified for use with a power supply of 230v 50Hz gt This manual includes the product warranty gt Specifications and contents of this manual may be changed without prior notice in accordance with our commitment to product quality design and control ALON HEPHZIBAH CO LTD A 6 AIRREX lt Q Contents Safety Precautions Precautions for installation and before use Precautions for install How to install How to use power Configuration and name Main body Indication and operation part Remote control How to exchange dry cell of remote control How to use Operation stop and automatic operation function Manual operation function On Timer function How to stop How to operate stop fan How to dianose safety device Storage Instructions Troubleshooting Specification Product warranty n AIRREX Q Safety Precautions These precautions are designed for keeping users safe
3. power Operate heater normally after 5 250V15A allowing to cool down a MEMO 4Sn 40 NOlLdldOS3d S AIRREX Q Storage Instructions e Disconnect from power supply e Ensure main body is clean e Cover the heater with the and dry covering supplied when you purchased the unit Keep it in a well ventilated dry place AIRREX HEATER 4 p precautions for examination and handling Handle heater when it is completely cooled down and power is cut off Never disassemble for operation devices including safety ones are not properly operated Troubleshooting Is electricity supply working X Check the main power supply is working Check that the power plug is plugged in gt Tum on the product once again after plugging in AH 720 Is the circuit breaker off gt Reset circuit breaker AH 765 780 CJ AIRREX Wiring diagram Power AC 230Va c 50Hz Plate of Far Infrared Rays POWER CODE AC 230V 50Hz HALOGEN LAMP Pite ol Farintred Rays gy o ooo o Ground H Sem c5 Connection Temperature Sensor Power S W 250V 16A Tilt Sensor FRONT CONTROLLER wei J Poe AH 765 380Va c 3ph 120 TERMINAL BLOCK
4. and preventing material damage Be sure to read them and use the product correctly e There are 3 classifications of safety precautions and they are listed in the box below A RISK Possiblity of death or severe injury in the event of mishandling A WARNING Possiblity of death or severe injury in the event of mishandling A CAUTION Possiblity of injury and or material damage in the event of mishandling x Meaning of picture signs aD Indicate prohibition Q Indicate contents that people must carry out After reading this be sure to keep it at a place where other users can refer to it at any time Do not leave or use pressure vessel around heater Can cause explosion SNOILNVIAYd 3 AIRREX After reading this be sure to keep it at a place where other users can refer to it at any time Use specific 230V 13 amp socket to prevent fire amp electric shock Ensure that the circuit breaker or fuse supplying the socket is fit for the capacity required incorrect breaker could cause a risk of breakdown or fire Ensure you hold the power plug properly when either plugging in or unplugging Always turn off the unit by use of its on off switches and never by just pulling the mains plug or tripping the circuit breaker al i I l je Never place the unit near combustible products such as curtains carpets etc This can cause a fire Ensure both plug and socket is clean and free from dust when u
5. d even surface NM fmm 9 JI 9 GE Do not try to take the unit apart or repair it Never jar the product Do not touch hot parts whilst in use do not place hands on the unit as it gets very hot during its heating operation Always turn it off and allow it to cool before handling Children must be kept away from the heater Keep heater away from other electric domestic appliances They could get damaged due to high heat um 0 T e EC When thunder and lighting is present turn off the unit and disconnect from the power supply Disconnect from power supply when the unit is not being used for a long period m Im Ja Il Do not place heavy objects on the product can cause breakdown or electric shock and you can get injured when objects fall down Do not use the unit on unstable or unsafe surfaces a aD Do not clean the product before disconnecting from power and allowing it to cool down Store the product in dry indoor locations and not in hot or humid locations CNY t T S a 150 9 AIRREX Q Precautions for installation and before use After reading this be sure to keep it at a place where other users can refer to it at any time D Install the product at places where bottom is solid a Install the product at places that are visible to and even the product cannot be working at tilted people f
6. eater 8 Auto lamp If you select Auto Auto lamp is on 9 Fan lamp If you select Fan Fan lamp is on 10 Operation lamp Operation lamp is on during heater operates n AIRREX m Point the remote control towards the receiver whilst using it operation stop button gt m Remote control will not work from a distance when strong lighting or sunlight is present automatic manual gt a button for controlling In this case use the remote control just in E the amount of heat front of the control panel button ventilation button gt and temperature m When you select a function with the remote control you will hear a bleep InfraPlate m When the remote control is not used for a long period please remove the battery to avoid leakage and damage m Do not allow water or liquid to get into AIRREX gt AH 765 780 the remote control m Use the magnet which is in the remote control to fix it to the side panel of the unit M On Timer button m When using the remote control for the first time remove the vinyl covering at the lower part of the control unit 3S dO NOlLdldH2S3d KAH 720 w Bed 1 Open over of dry cell Press part toward the direction shown by arrow Pull part toward the direction shown by arrow 2 Exchange dry cell Put dry cell in the indication of 3 Close cover Push cover on a level until it sounds click AIRREX Q How to use 1 S
7. facilitate return Return to customer will be at dealers cost if genuine warranty claim DESCRIPTION AIRREX HEATER MODEL AH 720 765 780 PRODUCT Warranty Period Months DISTRIBUTOR Telephone No CUSTOMER i Telephone AIRREX e 2 AIRREX HEPHZIBAH CO LTD 1385 15 JUAN DONG NAM GU INCHEON KOREA TEL 82 32 509 5834 FAX 82 32 502 5519 E mail airrex airrex co kr Website www airrex co kr
8. lity sensing device Controlling method Digital micom controlling and remote control On Timer function AH 720 automatic manual operation function Controlling function 4 steps heat amount control fan on off selection function room temperature function abnormality and operation indication function Safety device Designs and specifications of this product can be changed without any prior notice to improve the quality and enhance efficiency ca n AIRREX WARRANTY Applicable to first retail purchaser only AIRREX HEATER give more reliable performance comfort and durability the more they are used They are built under a strict quality assurance regime which includes inspection both during and after production and exhaustive reliability testing In the unlikely event you have any problems please contact your dealer or distributor If the problem is as a result of a production fault or failure repairs will be undertaken free of charge during the period of warranty subject to the following warranty conditions 1 The warranty period is 12 months from the date of first purchase 2 If the problem has been caused by customer error or misuse abuse or damage then all repairs will be charged for 3 Proof and date of purchase must be supplied 4 Please complete the details below and keep this warranty in a safe place 5 All transport charges back to the dealer are at the customers cost Keep all original packaging to
9. n 1 hour and 24 hours for one second X without entering separate buttons ree the setting is kept three seconds later and 2 The timing is automati is lighted cally cancelled when you cancel operation by pressing operation stop button LE IP CONTROL AUTO PITTTHE LT UJON FAN D a 1 If you press operation stop button during operation 2 If you leave the unit unattended for a long period the operation is immediately stopped ensure that it is switched off and remove the plug from the power socket circuit breaker AH 765 780 4Sn dO NOlLdldMOS3d n AIRREX 2 When you press fan button while fan is is turned off and fan is stopped 1 When you press fan button while heater is in operation amp fs is indicated in window and in operation e fan is operated Lem coniu mi mg ex AUTO TEMP SETTEMP nme DON F mim Kc AIRREX e serp mI Cic o E Auto Kx will PL L H L H a fe 2 When you press fan button while fan is in operation oF is indicated in 1 When you press fan button while heater window and fan is stopped is in operation on is indicated in window and fan is operated AIRREx s AIRREX um Q How to diagnose safety device Xx perceive abnormality of temperature sensor overly heated room temperature prevention device indicated as E 1 n the event that present indoor temperature a n the e
10. requently observe the product for safety Bx c o titedplaces Install the product at places where users always reside and be sure to equip fire extinguisher Jal Use the product at places without sulfurous acid gas emulsified gas or chlorine gas AJ BS X i i Keep packaging parts because they are necessary in maintaining the heater for a long time gt Use the unit in places with easy access to X Always leave a clear power sockets and that are well ventilated space of at least 20cm from the left right and gt Never use connecting terminals in the power rear panels of the unit lead Always directly connect the unit to the The unit must also have p power atleast 1 5m clear space Cold air above it Never put any obstacles nearer than 1 5m to the front of the unit SNOILNVIAYd 3 AIRREX X When using 230V AH 720 Put plug into specific outlet for 230V with earth terminal MEMO Q Configuration and Name safety grille control panel handle side reflector far infrared rays plate rear reflector base reflector fan castor near infrared rays lamp AH 765 safety net indication operation part handle side reflector far infrared rays plate rear reflector base reflector fan rubber foot for controlling the level 9 AIRREX g
11. sing Never remove the plug from the socket by pulling the mains lead Never touch the plug with wet hands risk of electrocution and or fire Do not kink or place the main power lead under heavy objects risk of electric shock or fire Ensure that the unit is properly earthed through the mains power circuit Never put hands or objects into the main body of the product Never touch it immediately after use risk of fire burns or electric W Jn Hi Never use with a damaged power lead plug or loose wall socket this can cause electric shock short circuiting or fire AH 720 Do not extend the power cord risk of breakdown or fire CHER Do not overload the dedicated power socket with other equipment Do not install use or place any combustible liquids or gases near the product risk of fire or explosion Never place combustible objects on the product such as vinyl and plastic items can cause a risk of fire E 9 AIRREX After reading this be sure to keep it at a place where other users can refer to it at any time Never use the unit in places such as bathrooms shower rooms near swimming pools or anywhere near water electrocution and or electric leakage can easily occur Never allow water to get into the unit by leaving it exposed to the rain or careless cleaning this could ca
12. t AH 720 Wil LM LI LI room temperature E sensor power switch gt AH 765 780 i sensor to perceive indoor temperature earth connection terminal x External appearance can be changed without prior notice for improving quality JWYN GNV NOILVYNDIANOD n AIRREX gt AH 720 gt AH 765 780 AIRREX TEMP SET TEMP Lic Oo Auto Sf POLL L H TEMP CONTROL AUTO U ON e FAN Signal receiver of remote control LED display Various conditions are indicated such as temperature time and abnormal condition button for temperature control Use the button used to control temperature or the amount of heat automatic manual button Use the button when you select automatic or manual operation FAN button Use for turning fan on or off On Timer button Use the button when you select On Timer button for operation stop Use the button when you turn on or off the heater LED Display Various conditions are indicated such as temperature time and abnormal condition Signal receiver of remoe control Heat Grade Lamp Heat amount is displayed from step 1 4 button for temerature control Use the bton sed to control temperature or the amount of heat automatic manual button Use the button when you select automatic or manual operation 6 FAN button Use for turning fan on or off T button for operatino stop Use the button when you turn on or off the h
13. tart operation by 2 Heater is turned on and operation is started l 3 press operation stop pressing operation with the sound of beep button once again to stop stop button AUTO DON FAN c5e Auto amp mil repetition x TEMP CONTROL TEMP CONTROL TEMP CONTROL AUTO AUTO AUTO 1 Start operation by 2 Select automatic operation 3 Control temperature you want by pressing pressing operation by pressing auto button temperature control button The range of set stop button AUTO lamp is turned on temperature can be controlled between 10X and 32X The amount of heat is automatically controlled and operated to be suit able for set temperature TEMP CONTROL tl A AUTO P CONTROL me sme IN FAN AUTO TES E tll E UJON FAN 1 t p 9 AIRREX 1 Start operation by 2 Select manual operation by pressing 3 Select the amount of heat you want pressing operation auto button AUTO lamp is turned off by pressing temperature control stop button button Selected amount of heat is operated regardless of temperature AUTO TEMP CONTROL AIRREXx UJON FAN cs AUTO 7 LES E E a i P CONTROL H N DA M E mw NC E s AUTO POO L H H UJON FAN 1 Press On Timer button 2 Set the time you want by pressing key of x Cancellation when operation is stopped Controlling up and down A V setting is 1 Press button On Timer possible betwee
14. use fire or electric shock If the power cord is damaged it must be replaced by a qualified electrician risk of electric shock or fire Never leave the product Switched on if it is covered by any objects or placed improperly as the programmer may automatically operate the unit and cause a fire Never move the product Do not use the unit other than for whilst it is switched on its intended use do not use for Always turn it off and allow drying clothing or for keeping itto cool down before animals or plants warm etc touching Jul Never spray water directly ab The safety grille does not onto the unit nor attempt to protect children or frail clean it with any solvents or people completely flammable liquids use under strict supervision this could cause electric shock ou y Do not use the product Do not place the heater whilst sleeping or away close to the electric socket from the premises risk of fire s The heater must not be located immediately below a socket outlet ba Do not use this heater in the immediate surroundings of a bath a shower or a swimming pool m f the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard FSN dO NOlLdldH2S3d n AIRREX After reading this be sure to keep it at a place where other users can refer to it at any time When in use the heater must be on a flat an
15. vent that sensor of present indoor exceeds 43 E2 is indicated and all activities are stopped temperature does not work properly E1 is indicated and all activities are stopped Note When causes of abnormality are resolved the X prevent overheating and perceive abnormality of conductivity safety product is automatically powered on Beep is stopped when you press operation stop button When indoor temperature exceeds 130 c while heater is in operation power of the product is cut off When the product is fallen down conductivity safety sensor is operated and power of the product is cut off 9 AIRREX Airrex heater is equipped with diverse safety device preventing a risk of fire In the event that heater is not working properly safety device is operated and heater is automatically stopped If heater falls over or is given a sharp jolt it will The unit will automatically stop if there is a power failure automatically switch off You must press the On button to continue use m After checking that there is no damage switch on again and operate normally during power failure a l If a power surge or unusually If the unit overheats and If the room temperature exceeds high current is induced in the the temperature inside the unit is 43 the unit will automatically turn off heater then the fuse and abnormally high it will automatically circuit breaker cuts off turn off the