1. All testing values recorded Press M button or wait for in the memory have been 3 minutes to turn off the shown meter An error message indicat Press the meter reset button ing a problem with the cod and check the meter again with the Glucode Chip If the problem persists contact Tyson Bioresearch Inc Cus tomer Service for help ing of the Meter Other problems that may occur ACTION The Test Strip has not been inserted into the Meter properly Review the instructions and re insert the Test Strip correctly white side face up Defective Test strip Replace with a new Test Strip Insufficient blood sample Repeat the test with a new Test Strip Test Strip remains in the test port for more than 3 minutes prior to testing Meter will automatically turn off Re insert the Test Strip to the test port LCD Screen on the Meter is blank when trying to preform a test Contact Tyson Bioresearch Inc Customer Service for help 35 Specifications Meter Operating Conditions Temperature Relative Humidity Hematocrit Test Sample Sample Volume Measuring Range Test Time Memory Capacity Average Power supply Battery Life Size Weight 36 10 C 40 C 50 F 104 F 10 90 35 55 Capillary Whole Blood from Fingertip Palm and Forearm gt 1 5 pl 20 600 mg dL 1 1 33 3 mmol l 10 sec 300 most recent results 14 days average
2. 2 Smart 608 Blood Glucose Monitoring System CE 0537 User s Manual For in vitro diagnostic use only 2Smart 608 User s Manual Table of Contents Important Information eeeesseeseeeseseeeeeeen eee nnnnnnn nennen nnne 3 Introductio aseina Naaa aaiae aar Saa AAE Sean anaa KXERRRRERFARRRS 7 About the Product 8 About the EZ Smart 608 Meter 9 About the EZ Smart 608 Test Strip 10 About the EZ Smart 608 Test Strip vial nenene ener nn rsrsserrr rn 11 About the Glucode Chip eene 11 Installing Replacing the battery 12 setting Up the Meter oie tee eene nn tee eterne 13 Checking the performance of your EZ Smart 608 Meter 15 Coding your EZ Smart 608 Meter sss 15 The Control Solution Test 16 Testing your Blood Glucose Level eee 20 Preparing the Test Strip 21 Obtaining a blood sample 22 Applying blood sample to the EZ Smart 608 Test Strip 23 Memory Featutes ener iaia 25 PG LinicEunctlon rentrer erret ai res e es RA ERES 26 Gare andi Storage i ina ini 28 Display M6Ssagpes einem repere 30 Specifications 5 ret erit eee texto e eere ri aient Era Ee rua s 36 Limitations of the ProCeCUure ccccccecceeeeeeeeeeeececeeeeeeeeseeseneiaaeeeeeeee
3. Twist and remove the protective lancet cover to expose the sterile needle tip 4 Recapping and screwing the endcap to the body of the lancing device 5 Pull back on the cocking mechanism until it comes to a stop 6 Place the lancing device firmly against the finger tip and press the release button PERFORM THE TEST 7 After sampling remove the endcap containing the used lancet carefully 8 Remove the lancet from the lancing device Discard the used lancet prop erly in accordance with local state and federal law Applying Blood Sample to the EZ Smart 608 Test Strip 3 As soon as enough blood has filled the Confirmation Window see picture of the V JA 1 After obtaining a blood sample place the drop L onto the test well Test Strip the Meter will of the Test Strip beep and begin counting down from 8 to 1 Confirmation Window 2 Blood is auto w 4 Your blood glucose 5 matically drawn f l Da result will appear on into the Test th LI the LCD panel and e Strip B t 8 36 will be stored into the Meter memory automatically Note To ensure accurate results make sure the Confirmation Window of the Test Strip is dai Jai completely filled with your blood sample 23 5 The EZ Smart 608 results range between 20 to 600 mg dL 1 1 to 33 3 mmol l If a HI message appears on your display your Met
4. Bring the tip of the Test Strip to lightly touch the drop of Control Solution Control Solution is automatically pulled into the strip through the tip Hold until the meter beeps The meter will now being counting down from 8 to 1 and the Control Solution test result will appear Lo de Caution Please remember that in order to prevent contamination follow the above instructions for preforming the Control Solu tion test Comparing Control Solution Results The EZ Smart 608 Meter is functioning properly if the result falls inside the specified range printed on the Test Strip vial If the test result falls outside the specified range repeat the test Results falling outside the specified range may be caused by m Error in performing the test m The Control Solution temperature is lower than15 C 59 F or higher than 35 C 95 F m Expired or contaminated Control Solution m Expired or contaminated EZ Smart 608 Test Strips m Improper coding of the EZ Smart 608 Meter m EZ Smart 608 Meter malfunction Note The result will not be stored into the memory and will not be incor porated into the average in the ctl mode DO NOT use the system if the problem persists Please call Tyson Bioresearch Inc Customer Services at 886 37 585998 or website of www tysonbio com 19 20 Testing your Blood Glucose Level Before testing blood glucose you need the following items 1 EZ Smart 608 Meter 2 EZ
5. Confirmation Window This is where you can confirm that enough blood has been applied to the target area 2 Target Area This is where blood is drawn into the Test Strip 3 Contact Bar This end of the Test Strip is inserted into the meter Test Port to activate the Meter white side face up FRONT BACK I e le About the EZ Smart 608 Test Strip Vial VIAL LABEL TEST STRIP VIAL Do not refrigerate Re cap immediately E2Smart 608 For in vitro diagnostic use Blood Glucose Test Strips C o537 Do not store test strips outside this vial Lot G3T131036 7 Lot Number Store at 4 30 C 39 86 F Exp May 2010 _ cH For the measurement of P y Expi ration Date glucose in whole blood Control Solution Range L 31 61 mg dL 1 7 3 4 mmol l IN 84 144 mg dL 4 7 8 0 mmol l Code 1 0 Test Strips 956 IH 348 438 mg dL 19 3 24 3 mmol l Use EZ Smart 608 only Code Number Control Solution Range About the Glucode Chip The Glucode Chip is used to ensure that your EZ Smart 608 Meter provides you with accurate results Before perform ing the blood glucose test or starting a new strip vial please check your Meter with the Glucode Chip to ensure proper performance further instructions for use of the Glucode Chip is provided on page 15 After checking your Meter the Glu CODE Number code Chip is also used to code setting 11 m Note Always use the Glucode Chip to ensure yo
6. Smart 608 Test Strip 3 Glucode Chip 4 Adjustable Automatic Lancing Device 5 Sterile Lancet Caution To reduce the chances of infection m Never share a lancing device and lancet with another person m Always use a new and sterile lancet Lancets are for single use only m Always use a new EZ smart 608 Test Strip Test Strips are for single use only m Do not get lotion oil dirt or debris in or on the lancet and lancing device Preparing the Test Strip 1 Wash hands using soap and warm water Rinse and dry thoroughly Fig 1 2 Pull out the Test Strip from the vial and re cap the vial immediately Fig 2 3 Insert the Test Strip white side face up into the test port Fig 3 4 A beep will sound and the code number will appear followed by a flashing e symbol Now you are ready to obtain a blood sample Fig 4 M Vola ual 612 Fig 3 Fig 4 Reminder Make sure that the code number on the display matches the code number displayed on the Test Strip vial If the code number on the dis play does not match the code number on the Test Strip vial code the Meter by using Glucode Chip accordingly See page 15 21 22 Obtaining a Blood Sample SAMPLE MAY BE OBTAINED FROM FINGER PALM or FOREARM For further instructions please see the insert provided with lancing device 1 Unscrew and remove the endcap of the lancing device 2 Insert the lancet into the lancet holder 3
7. advice of a physician or healthcare professional is not recommended e Severe dehydration and excessive water loss may cause false low results If you believe you are suffering from severe dehydration consult your phy sician immediately Introduction Thank you for choosing the EZ Smart 608 Blood Glucose Monitoring Sys tem the latest advancement in biosensor technology As you already know self monitoring of blood glucose SMBG is a necessary part of the treatment plan of people with diabetes mellitus The Diabetes Control and Complica tions Trial DCCT has confirmed the significant benefits from SMBG when practiced as part of a larger intensive strategy to tightly control blood glucose concentrations Adapted for its ease of use and quick response time the EZ Smart 608 Sys tem has the ability to process accurate results utilizing only a small volume of blood for in vitro diagnostics The EZ Smart 608 Blood Glucose Monitoring System is intended for use in the home and in professional settings to moni tor whole blood glucose levels obtained from the fingertip palm and forearm This is an over the counter OTC product Please read the entire User s Manual carefully before using this prod uct About the Product Your EZ Smart 608 System is made up of several components This booklet is designed to guide you through the operation of the system with detailed directions and pictures Your EZ Smart 608 System contains m EZ Sm
8. results 3 Volt lithium battery CR 2032 Approximately 1000 tests 102 x50 x15 mm 4 0 x 1 9 x 0 6 in 55g mThe EZ Smart 608 Meter and EZ Smart 608 Test Strips are in conformity with the IVDD 98 79 EC Manufacturer Authorized representative in the EU Tyson Bioresearch Inc Medical Device Safety Service GmbH 5F 22 Ke E Road III Science Based Schiffgraben 41 D 30175 Hannover Industrial Park Chu Nan 350 Germany Miao Li County Taiwan R O C TEL 49 511 62628630 TEL 886 37 585998 mThe Lancets are in conformity with the MDD 93 42 EEC Manufacturer Authorized Representative in the EU Wuxi Xinda i l EMDAR BV Medical Device Co Ltd ljsselburecht 3 Postbus 5486 No 42 Xixin Road Zhangjing 6802 EL Arnhem Netherlands Wuxi Jiangsu 214194 PRC TEL 31 263 653 375 TEL 86 510 379 3149 37 38 mThe Lancing Device is being clasified as MDD Class I Manufacturer Authorized Representative in the EU Wuxi Xinda EMDAR BV Medical Device Co Ltd A lisselburecht 3 Postbus 5486 No 42 Xixin Road Zhangjing 6802 EL Arnhem Netherlands Wuxi Jiangsu 214194 PRC 31 263 653 375 TEL 86 510 379 3149 Limitations of the Procedure Caution The EZ Smart 608 System is designed for in vitro use only and is not intended to test on newborns The EZ Smart 608 Test Strips are designed for use with fresh capillary whole blood samples obtained from the fingertip palm and forearm False results may occur when performing t
9. 1 Control Solutions are required but not supplied 2 There are three Control Solutions at different desired range of aqueous glucose Low Normal or High For more information about the Control Solution please read your Control Solution package insert Two sets of control solution should be used a high level and a low level control solu tion of your choice To perform a Control Solution Test 1 Insert the Test Strip white side face up Contact Bar s end first into the test port The Meter will automatically turn on Mem mmol l mg dL 88 8 808 8 885 2 All segments of the LCD display will ap pear indicating that the Meter is function ing properly 17 18 3 A beep will sound and the code number will appear fol lowed by a flashing symbol Be sure the code number on the display matches the code number on the Test Strip vial If the code numbers do not match code the Meter by using Glucode Chip accordingly After the e symbol appears press the S button for 3 sec to switch ctl mode The ctl symbol indicates that the Meter will mark your current test as a Control Solution test Now you are ready to apply the Control Solution Discard the first drop of Control Solution and squeeze a small drop of Control Solution on a clean nonabsorbent surface such as a clean piece of wax paper Do not apply Control Solution to the Test Strip directly from the bottle
10. art 608 Meter m One vial of EZ Smart 608 Test Strips 10 strips m One Glucode Chip outside the strip vial m One Lancing Device Optional m Ten Lancets Optional m One carrying case m User s Manual m Log book Optional m Quick Reference Guide m One vial of Control solution Optional Note 25 50 test strips vial can be purchased individually About the EZ Smart 608 Meter The FRONT The BACK 1 Display Your test results are displayed here The large easy to read screen guides you through the test by using numbers and symbols 2 M Button The M mode button is used to set the year month day time enters the memory mode to show the consec utive 14 day average results and turns the Meter on and off S Button The S select set button is used to select the year month day time memory of results and control solution mode Test port This is where you insert the Test Strip into the Meter Unit Switch Switch for mmol l or mg dL 6 Battery Cover 7 Label Reset Button Press this button to re set the system Glucode Chip Insert the Glucode Chip for coding 0 Data port Connect interface cable to transfer data C 000 f 10 About the EZ Smart 608 Test Strip The EZ Smart 608 Test Strip is used to perform the blood glucose test in conjunction with the EZ Smart 608 Meter Each strip can be used only once The EZ Smart 608 Test Strip consists of the follow ing parts 1
11. er has detected that your blood glucose level is higher than 600 mg dL 33 3 mmol l It is suggested that you review your testing procedure and test again with a new Test Strip to confirm the result If the same result oc curs consult your healthcare professional immediately 6 If a LO message appears on your display your Meter has detected that your blood glucose level is lower than 20 mg dL 1 1 mmol l It is suggested that you review your testing procedure and test again with a new Test Strip to confirm the result If the same result occurs consult your healthcare professional immediately If no further tests are performed the Meter will automatically shut off after 4 minutes After finishing the test we recommend using a tissue paper to remove the Test Strip from the Meter for proper disposal Caution Any change or administer of medication based on the EZ smart 608 blood glucose test results without the consent advice of a physician or healthcare professional is not recommended Memory Features The EZ Smart 608 Meter automatically stores the 300 most recent blood glucose results with date and time in its memory It also provides you with a consecutive 14 day average of your blood glucose test results 1 Press the M button to turn on the Meter All segments of the LCD display will ap pear Fig 1 2 The date and time will appear first Fig 2 followed by the Control Solution test re sult Fig 3 3 Wait a few second
12. es 38 Service and Warranty ine 39 Customer Service s iiii een eor deo kegae ra oa Ra ea basaa aaa 41 Important Information Available Alternative Sites Testing Palm and Forearm EZ Smart 608 Blood Glucose Monitoring System provides you alternative sites testing AST This system provides you to test on the palm and the forearm with the equivalent results to fingertip testing There are limitations for doing AST Please consult your healthcare profes Palm xd sional before you do AST Forearm Alternative site results differ from fingertip results when glucose levels are changing rapidly such as after a meal after taking insulin during exercise or when you are ill or under stress Use blood from a fingertip rather than an alternative site if e you think your blood glucose is low e you don t regularly have symptoms when your blood glucose is low or e how you feel doesn t match the results from the alternative site e When you have just taken insulin or any time during or after exercise e When there are unknown variables occurring in your day such as illness e Whenever you are about to drive 1 Physiologic differences in the circulation between the finger and other test sties like the forearm and palm may result in differences in blood glucose measurements from the other test sites and your fingertips Changes in blood glucose may be observed in finger blood samples sooner than blo
13. he test while severely dehydrated severely hypotensive in shock or in a hyperglycemic hyperosmolar state If you believe you are suffering from any of the above symptoms consult a healthcare professional immediately Service and Warranty IMPORTANT The EZ Smart 608 Blood Glucose Monitoring System is designed for in vitro diagnostic use only Tyson Bioresearch Inc cannot endorse the performance of the EZ Smart 608 System when used with Test Strips other than those designed for the EZ Smart 608 Meter The EZ Smart 608 System manufacturer warranty is valid only when used properly within the guidelines of the provided User s Manual and is invalid when the EZ Smart 608 System and EZ Smart 608 Test Strip are used improperly Manufacturer Warranty Tyson Bioresearch Inc guarantees that this de vice will be free of defects in materials and workmanship for a period of three years from the date of original purchase During the stated three year period our company shall repair or replace any EZ Smart 608 Meter found defective with a new EZ Smart 608 Meter 39 40 This warranty does not apply to the performance of a EZ Smart 608 Meter that has been accidentally damaged altered misused tampered with or abused in any way In no event shall our company be liable to the purchaser or any other person for any incidental consequential or punitive damages arising from or in any way connected with the purchase or operation of the EZ Smart 608 Mete
14. is advised that you store the Meter and its accessories into the provided carrying case For healthcare professionals using this system on multiple patients please be aware that all items that come in contact with human blood should be handled as potential biohazards Users should follow the guidelines for prevention of blood borne transmittable diseases in a healthcare setting for potentially infectious human blood specimens as recommended in the National Committee for Clinical Laboratory Stan dards Protection of Laboratory Workers from Instrument Biohazards and Infectious Disease Transmitted by Blood Body Fluids and Tissue Approved Guideline NCCLS document M29 A ISBN 1 56238 339 6 29 Display Messages DISPLAY WHAT IT MEANS ACTION ag ctl Code QUE lt u LO CES Mem mmol l mg dL 88 8 8x58 8 8 8m System check verifying that all segments of the Meter are functioning This message appears im mediately if your Meter has not been encoded This is the current code number in use No Action Necessary Code Meter see page 15 This code number should match the code number printed on your Test Strip vial DISPLAY WHAT IT MEANS ACTION Lo dE mg dL 5e The system is ready to ac cept a blood sample The system is ready to accept a Control Solution sample The Meter detects blood glucose level is higher than 600 mg dL 33 3 m
15. mol l You may now apply a blood sample You may now apply a drop of Control Solution sample Indicates high blood glu cose level Repeat test If result still occurs consult your physician immedi ately DISPLAY WHAT IT MEANS ACTION The Meter detects blood Indicates low blood glucose glucose level is lower than level Repeat test If result 20 mg dL 1 1 mmol l still occurs consult your physician immediately Temperature is too low to Repeat the test in a warm perform the test er setting 10 40 C or 50 104 F Wait 15 minutes before re testing Temperature is too high to Repeat the test in a cooler perform the test setting 10 40 C or 50 104 F Wait 15 minutes before re testing DISPLAY WHAT IT MEANS ACTION An error message indicat Review the instructions ing a problem with the Test and try again with a new Strip Test Strip Battery power is too low Replace with a new 3 Volt for further usage lithium battery CR 2032 An error message indicat Press the meter reset button ing a problem with th and check the meter again i P 9 with the Glucode Chip If the eter problem persists contact Tyson Bioresearch Inc Cus tomer Service for help DISPLAY WHAT IT MEANS ACTION Battery power is low Me Replace with a new 3 Volt ter will provide approxi lithium battery CR 2032 mately 50 more measure ments
16. od samples from the forearm and other alternate sites Rub the alternate test sties about 20 seconds before lancing If you are testing for hypoglycemia low blood glucose or if you suffer from hypoglycemia unawareness we recommend that you test on your fingertips 2 Talk to your doctor to see if alternative site testing is right for you With a little bit of education you can give your fingertips a rest and maybe test more often than you do now For people with diabetes more frequent test ing is a good thing Just remember any time you want to be sure of an ac curate up to date blood glucose reading test on your fingertip 3 We strongly recommend you do AST ONLY in the following intervals e In a pre meal or fasting state more than 2 hours since the last meal e Two hours or more after taking insulin e Two hours or more after exercise e Low or high blood glucose readings can indicate a potentially serious med ical condition If your blood glucose reading is unusually low or high or if you do not feel the way your reading indicates repeat the test with a new test strip If your reading is not consistent with your symptoms or if your blood glucose result is less than 60 mg dL 3 3 mmol L or higher than 240 mg dL 13 3 mmol L you should contact your healthcare professional and follow his or her treatment advice e Any change or administer of medication based on the EZ Smart 608 blood glucose test results without the consent and
17. of www tysonbio com 2 Install the software on a computer Follow the instructions provided with software to install the software 3 Get ready to transfer test results Setting the meter to the PC link mode see page 13 PC will appear on the display Connect the interface cable to a serial LI i port on your computer Then connect the other end of interface cable to the data port located on the side of the meter 4 Transfer data Follow the instructions provided in the software to download the results from the meter After finishing the data transfer press M button to turn off the meter Note While in the communication mode you will be unable to perform a blood glucose test If the meter is not in the PC link mode it will not respond to computer commands 27 28 Care and Storage 1 Handle the EZ Smart 608 Meter with care Dropping or throwing the Me ter may cause damage to the device 2 Do not expose the Meter Test Strips and Control Solution to extreme con ditions such as high humidity heat freezing cold or dust 3 Always wash hands with soap and water and rinse and dry completely be fore handling the Meter and Test Strips 4 When cleaning the Meter gently wipe the exterior surface using a damp soft cloth DO NOT USE ANY ORGANIC SOLVENT for cleaning 5 The Meter should be stored at room temperature in a dry and clean space DO NOT STORE IN DIRECT SUNLIGHT OR AREAS WITH HIGH HUMIDITY AND OR DUST It
18. or start a new strip vial please Mem mmoll mga continue the coding procedure 88 8 8x08 8 8 Br Coding your EZ Smart 608 Meter Each batch of EZ Smart 608 Test Strip is encoded with a number that must match one of the code numbers stored in the EZ Smart 608 Meter In or der to ensure an accurate result the code number on the display must also match the code number found on the Test Strip vial 1 Insert the Glucode Chip into the Glucode Chip slot The Meter will auto matically be encoded Note Code the Meter whenever you start a new test strip vial 2 All segments of the LCD display will appear indi Sca cating that the Meter is functioning properly Then a beep will sound followed by the code number T 9 19 3 Match the code number on the Meter display with Mem mmoll mg dL 88 BB85 88 885 the code number on the Test Strip vial label If the code matches you may begin to test Code WP um UP 4 f the meter code and vial code do not match Li L L please ask the store distributor to replace a new Fre 20 20 6 8 vial The Control Solution Test The Control Solution is used to check and ensure that the EZ Smart 608 Meter and EZ Smart 608 Test Strip are working together properly and that you are performing the test correctly For an accurate reading check the system with the Control Solution on a routine basis approximately once a 16 week NOTE
19. r or its parts For manufacturer warranty services purchaser must contact Tyson Bioresearch Inc for help Customer Service If you have any questions or concerns regarding this product and or its op eration or any attempt to correct a problem fails please call our Customer Service Unit Our trained specialists will be happy to assist you train you or even reaffirm your results Customer Service Hotline 886 37 585998 our office hours are from 8 30am GMT0030 5 30pm GMT0930 or E Mail us at service tysonbio com When you call our Customer Service Unit please have your EZ Smart 608 Meter EZ Smart 608 Test Strip and all other system supplies available This will allow us to answer any of your questions with speed and efficiency 41 Tys nBio Manufacturer Tyson Bioresearch Inc 5F 22 Ke E Road III Science Based Industrial Park Chu Nan Taiwan Tel 886 37 585998 Fax 886 37 585996 ID B03E106357 www tysonbio com Made in Taiwan Revision 02
20. s and the consecutive 14 day average will automatically appear and a 14 DAY AVG symbol will flash Fig 4 gt CO ctl Code Voti LL an BEEN Led 154 124 CALI th 98 8928 8 8 8s B i2 8 38 em Moya Fig 1 Fig 2 Fig 3 Fig 4 25 lt 9 Wait a few seconds and the most recent test result will automati I DN cally appear Each time you press the S button the Meter will re u L LI call the last 300 test results accordingly When the memory is full Ble Bb the oldest result is removed and replaced with the newest result Note If there is no test result during this stage it will directly appear the most recent test result Exiting the Memory Mode 1 Press the M button to turn off the meter 2 Meter will shut down automatically after 3 minutes with no further action Note The consecutive 14 day average is calculated from the blood glucose results obtained during the last consecutive 14 days To Record Your Results We have provided a log book for your recording convenience To learn more about how to record your results please refer to the log book for further in structions PC Link Function You can use your meter with TysonBio Link Diabetes Management Software 26 to transfer test results to your personal computer Obtain the required sofeware and cable For order information please call Tyson Bioresearch Inc Customer Service at 886 37 585998 or website
21. sh 4 Press and release the S button until the correct day appears With the correct day on the display press and release the M button to bring up the hour and minute display 13 5 Press and release the S button until the correct hour appears With the correct hour on the display press the M button and the minute display will flash 6 Press and release the S button until the correct minute appears When the correct minute is on the display press the M button to move on to PC link mode If you press S button yes it will appear PC link mode for transferring test data Further instruction of transferring test data see page 22 To finish setting press M button no to turn off the meter Your programmed settings will be shown on the display every time you use the Meter N q C m za ca uc m un Code Setting and Unit Selection 1 Select unit mg dL or mmol l on the back The mg dL is the standard unit in the United State 2 Plug the Glucode Chip into the Glucode gt Chip slot for strip coding Checking the Performance of your EZ Smart 608 Meter The Glucode Chip is used for checking and coding your EZ Smart 608 Meter To Check your Meter 1 Insert the Glucode Chip into meter s Glucode Chip slot as T ur All segments of the LCD display will appear indicating Li Li Li that the Meter is functioning properly jx ist jel 2 If you are a first time user
22. ur EZ Smart 608 Meter is performing properly m DO NOT misplace your Glucode Chip Installing Replacing the battery The EZ Smart 608 Meter uses one 3 Volt lithium battery CR 2032 When to Replace the Battery When the battery is low the Meter will show a warning sig c nal When this display appears it is time to replace a new battery When the low battery warning signal is shown the L EZ smart 608 Meter will provide accurate results for ap proximately 50 more measurements How to Replace the Battery 1 From the back of the Meter gently slide and remove the battery cover 2 Insert a 3 Volt lithium battery CR 2032 with the side facing up 12 3 Slide battery cover back into place Setting Up the Meter To turn the Meter on first put the battery into the battery chamber then press the reset button located at the back of the Meter and proceed with the following instructions Setting Up the Date Time Unit and Enter PC Link Mode 1 Press and hold the M button for 3 seconds The Meter is now in the setting mode 2 The Year setting will be the first to appear Press and release the S button until the correct year appears With the correct year on the display press the M button and the month and date setting will appear 3 Press and release the S button until the correct month appears With the correct month on the display press and release the M button and the day setting will fla