Home

User Guide (Integrated Solid) - U-Line

image

Contents

1. ERATING INSTRUCTIONS e MAINTENANCE SERVIC Hinge by Hinge Installation Mullion When installing two units hinge by hinge 13 16 22 mm is required for integrated models Additional space may be needed for any knobs pulls or handles installed j 13 16 22 mm Stainless steel models which include the standard stainless handle will require 4 9 16 116 mm to allow both doors to open to 90 at the same time ei 116 mm Side by Side Installation 1 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP Water Hookup PREPARE PLUMBING Please use the braided stainless steel water supply line which comes attached The water line is fitted with a standard 1 4 6 35 mm compression fitting Prior to installation determine if this product contains a gravity style drain or factory installed drain pump Products without a drain pump may only use a gravity style drain Failure to connect water supply or drain line connections properly may result in water leakage personal injury and or property damage Disconnect power and turn off water to the unit before attempting to alter these connections These connections are the responsibility of the owner and must be connected per local plumbing code If you are uncertain of how to safely and properly install this pr
2. Disposal Assembly P60 Pump Required Air Gap Optional Hook Up f Fi l Waste Hl 3 gt li lt Cold i lt Hot Water Water r Shut Off Valve ERATING INSTRUCTIONS e MAINTENANCE SERVIC Y Branch Tailpiece P60 Pump Required Air Gap Optional Hook Up 0 23 gt waste Shut Off Valve Cold lt Hot Water NOTICE The maximum lift for the P60 drain pump is 10 feet This must be done as close to the rear of the unit as possible Drain 2 USERAGUIDE U LINE SAFETY e INSTALLATION amp INTEGRATION OP Drain Pump NOTICE PLEASE READ this instruction completely before attempting to install or operate the unit Improper hook up can result in substantial property damage If you are unsure of your ability to safely connect the drain pump to the unit consult a licensed plumber for assistance Use these instructions to install the U Line P60 00 drain pump in the U Line Clear Ice Machine unit The drain pump should be installed before installing the unit e The U Line P60 00 drain pump is designed to be used exclusively on the U Line Clear Ice Machine and is UL recognized only for use on the U Line Clear Ice Machine e U Line Corporation assumes no warranties or responsibility whe
3. NANC S RVIC Ice 2 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION e OPERATING INSTRUCTIONS MAINI Sabbath Mode 1 2 a 4 5 6 as Z Z L e o o o o o une amp B4 9 avert Up Select alr ome oL D U Line Clear Ice own Machine models are Star K certified and can be used during the Sabbath View a full list of Star K certified U Line u To prepare the u nits at www star k org nit for the Sabbath 1 Press and 2 No new ice wil made ice will hold the until the unit turns off form when the unit is off but previously still be accessible present for over 24 hours Pump equipped models will continue to remove water as needed even if the unit is off Sabbath Mode re and the unit turn mains active until 5 is pressed again s on NANC e SERVIC Sabbath Mode 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille at any time or the unit will not perform as expected Do not install the unit behind a door
4. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Warranty 6 2014 Rev G NANC e SERVICE Warranty 2
5. eS Grille Rail 5 Pull grille plinth strip base fascia free from unit ERATING INSTRUCTIONS MAINT NANC eS RVIC Installing the grille plinth strip base fascia 1 Align slots in grille plinth strip base fascia rail with Slide grille p screw heads in base of unit Push grille plinth strip base fascia rails towards the center of the unit and set rails over screw head inth strip base fascia into position Using included 7 64 Allen wrench tighten grille plinth strip Oc screws aal base fascia ADJUSTING GRILLE PLINTH STRIP BASE FASCIA The grille plinth strip base fascia has an automatic vertical plane adjustment and can also be adjusted on its horizontal plane as well To adjust your grille plinth strip base fascia to match your surrounding furniture follow th e instructions below Grille Skirt Loosen but do not remove the lock screws on the inside of the grille plinth strip base fascia rails Lock screws are located on the inside of each grille plinth strip base fascia rail Pull grille plinth strip base fascia out to desired position and secure lock screws The grille plinth strip base fascia skir
6. Open door completely Make certain door clears surrounding cabinetry Anti Tip Bracket 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINT NANCE e SERVIC 5 Using a 3 32 drill bit drill 3 pilot holes 5 8 16 mm deep into cabinetry frame using the anti tip bracket as a template 6 Install the 3 remaining 8x5 8 screws into the plate using a 2 Phillips head screwdriver Anti Tip Bracket 2 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINTENANCE e SERVIC General Installation 1 Use a level to confirm the unit is level Level should be placed along top edge and side edge as shown 2 If the unit is not level K Ne remove grille and U J adjust legs as A AS necessary Use included tool to adjust the height of the rear legs ro GA U o A e Ph A A 2 Cog Rotate Front Legs to Adjust 7 Rotate Clockwise to raise rear leg Rotate Counter Clockwise to lower leg 3 Confirm the unit is level after each adjustment and repeat the previous steps until the unit is level INSTALLATION TIP If the room floor is higher than the floor in the cutout opening adjust the rear legs to achieve a total unit rear height of 1 8 3 mm less than
7. and 2 for all Marine RV and Domestic U Line products sold and serviced in the United States including Alaska and Hawaii and Canada U Line shall be responsible for the labor costs incurred in connection with the replacement of any defective part of the sealed system All other charges including transportation charges for replacements under this warranty and labor costs not specifically covered by this warranty shall be the responsibility of the purchaser This warranty extends only to the original purchaser of the U Line product The Product Registration Card included with the product should be promptly completed by you and mailed back to U Line or you can register on line at www u lineservice com The warranty listed above does not apply to floor display models The warranty for these models shall be 30 days from the date of retail purchase and only if U Line s Product Registration Card included with the ERATING INSTRUCTIONS MAINTENANCE SERVICE unit is completed and mailed back or electronically submitted to U Line This 30 day warranty does not apply to cosmetic damages A proof of purchase may be required The following conditions are excluded from this limited warranty use of cleaners other than the recommended stainless steel cleaners and U Line Clear Ice Maker cleaner installation charges damages caused by disasters or acts of God such as fire floods wind and l
8. and away from heat generating equipment In climates where high humidity and dew points are present condensation may appear on outside surfaces This is considered normal The condensation will evaporate when the humidity drops Damages caused by ambient temperatures of 40 F 10 C or below are not covered by the warranty Environmental Requirements 1 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINT Electrical SHOCK HAZARD Electrical Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong grounding adapter Altering cutting or removing power cord removing power plug or direct wiring can cause serious injury fire loss of property and or life and will void the warranty Never use an extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit breaker is recommended A GFCI ground
9. Menu Poor Ice Quality Unit may not be level Check if unit is level ce maker may be dirty Clean ice maker Troubleshooting 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OP ERATING INSTRUCTIONS MAINT Not Enough Ice Problem Possible Cause and Remedy No Ice Ensure water is being supplied to the unit Production Verify the ice making unit is turned on Ensure the condenser coil is clean and free of any dirt or lint buildup Water in Bin Ensure the unit is plugged in Check if the drain is restricted Ensure drain is free of foreign debris and hose is not kinked or twisted Hear Running Water During ice creation the water evaporator may be heard running over the Hear Ice Falling nto the bin After each harvest ice will fal ERROR NOTIFICATION The 3000 model series continuously monitors a series of inputs and parameters to ensure proper and efficient operation of your unit Should the system detect a fault an error notification will be displayed on the user interface See below for a list of errors ID Description Solution No Comm Unit lost Disconnect and communication to reconnect power to the display unit Contact Customer Care if persistent Zone T Open Left or right zone Contact Customer thermistor circuit Care open Amb Thrm Open Ambient thermistor Con
10. display will show a countdown to switching the unit off To power your unit on simply press and the unit will immediately switch on NANC S RVIC First Use 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC Control Operation Up Zone Toggle Select 8 U LINE F i Power Down f U Select Lighting CONTROL FUNCTION GUIDE FUNCTION COMMAND DISPLAY OPTIONS OFF Press and hold Display will count down from 5 to off ON Press and release Unit will come on immediately Adjust lighting Press to adjust lighting Press 4 or a to set low medium or high Customer menu Press and hold for 5 seconds Press 4 or amp to scroll through menu Service menu Press 4 or and hold for 5 seconds Press 6 or to scroll through menu U SELECT CONTROL Digital Display The 3000 Series units are controlled by a feature rich advanced OLED display control unit The control panel allows adjustment to temperature set point access to Energy Saver Mode internal temperature readings and many other features U Select Lighting Up Select Down U Select Lighting 1 To begin press E4 to enter the lighting menu 2 Press B or amp to cycle through each available brightness setting Low Medium or High Press GJ to cy
11. fault circuit interrupter is usually not required for fixed location appliances and is not recommended for your unit because it could be prone to nuisance tripping However be sure to consult your local codes See CUTOUT DIMENSIONS for recommended receptacle location NANC e SERVIC Electrical 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINTENANCE e SERVIC Cutout Dimensions PREPARE SITE Your U Line product has been designed exclusively for a built in installation When built in your unit does not require additional air space for top sides or rear However the front grille must NOT be obstructed The Modular 3000 Series units are engineered with a variety of adjustment features to help ensure a seamless installation Adjustable doors leveling legs and grille will assist in fine tuning the installation All 3000 Series models fully integrate into overlay face frame inset or European frameless cabinet styles and install seamlessly into standard 24 610 mm depth cabinet base NOTICE Unit can NOT be installed behind a closed cabinet door U Line products are designed and manufactured to be seamlessly installed in the specified cut out openings shown and variance to the floors or cabinetry must be accounted for in your installation CUT OUT DIMENSIONS Preferre
12. has been altered or repaired in the field without prior written approval from U Line claims will not be eligible SERVICE INFORMATION Answers to Customer Frequently Asked Questions are available at u line com under Customer Care or you may contact our Customer Care group directly contact information below GENERAL INQUIRIES SERVICE amp PARTS ASSISTANCE U Line Corporation Monday Friday 8 00 am to 5 30 pm CST 8900 N 55th Street T 1 800 779 2547 ilwaukee Wisconsin 53223 USA F 1 414 354 5696 onday Friday 8 00 am to 4 30 pm CST Service Email onlineservice u line com T 1 414 354 0300 Parts Email onlineparts u line com F 1 414 354 7905 Email sales u line com u line com CONNECT WITH US f wW D Q rub in S Y blog Designed engineered and assembled in WI USA Introduction 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION e OPERATING INSTRUCTIONS MAINTENANCE SERVIC Safety and Warning NOTICE Please read all instructions before installing operating or servicing the appliance Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide SAFETY ALERT DEFINITIONS Throughout this guide are safety items labeled with a Danger Warning or Caution based on the risk type A DANGER Danger means that failure to follow this safety statement will result in severe personal
13. injury or death Warning means that failure to follow this safety statement could result in serious personal injury or death Caution means that failure to follow this safety statement may result in minor or moderate personal injury property or equipment damage Safety and Warning 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC Disposal and Recycling A DANGER RISK OF CHILD ENTRAPMENT Before you throw away your old refrigerator or freezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refrigeration appliances and follow these steps completely 1 Remove all consumable contents from the unit 2 Unplug the electrical cord from its socket 3 Remove the door s drawer s Disposal and Recycling 1 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINTENANCE SERVIC Environmental Requirements This unit is designed to operate between 50 F 10 C and 100 F 37 C High ambient temperatures 100 F 37 C or higher may reduce the unit s ability to reach low temperatures For best performance keep the unit out of direct sunlight
14. mm to 1 25 mm eS RVIC Side Integrated Panel U Line Unit 7F 3 5 16 89 mm to 1 25 mm Integrated Panel Dimensions 5 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP Extended Integrated Panel Dimensions BACK SURFACE MUST HAVE AMPLE FLAT SURFACE TO MOUNT INTEGRATED PANEL FLAT AND WITHOUT INTERFERENCE 3 4 y 20 mm A 17 1 2 445 mm gt K 30 to 33 7 8 762 mm to 860 mm Y Integrated Panel A minimum of 1 25 mm is required from the floor to the bottom of the extended integrated panel frame for proper ventilation ERATING INSTRUCTIONS MAINT NANC eS RVIC Integrated Panel Dimensions 6 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINTENANCE e SERVIC Integrated Grille Plinth INTEGRATED GRILLE PLINTH STRIP BASE i FASCIA DIMENSIONS Dimensions PREPARE AND INSTALL INTEGRATED GRILLE T PLINTH STRIP BASE FASCIA 5 1 Use the dimensions provided in the diagram to cut and SE shape your integrated grille plinth strip base fascia a panel Recommended panel thickness is between 1 4 Te y 6 mm and 3 8 9 mm Height will vary from 3 5 16 A 84 mm to 4 5 16 110 mm based on your g
15. reduced toe kick grille application 1 Cut the panels to the dimensions listed in the appropriate diagram on the next page 2 Optional Stain or finish panel to desired stain or color Be sure to closely follow the instructions provided by the manufacturer 3 Optional Install handles and hardware NOTICE The door panel must not weigh more than 20 Ibs 10 kg It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed Appliance will need up to 34 1 2 876 mm to the underside of the counter to leave room for leveling adjustments When applying an integrated panel to a unit ensure that both sides are finished in order to prevent warping In some installations the panel may be visible through the glass while the door is open Integrated Panel Dimensions 4 USERAGUIDE U LINE u line com SAF Panel can extend beyond the door frame A minimum of 1 25 mm from the floor is required for proper ventilation ETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANC Front Side Integrated Panel Integrated Frame Integrated Panel Cabinet U Line Unit 3 5 16 89 mm y 3 5 16 89 mm gt 3 5 16 to t to gt 89 mm 4 5 16 114 mm 4 5 16 114 mm Floor Front Extended Integrated Panel Extended Integrated Frame i j 3 5 16 89
16. result in an integrated panel solution wherein the size of the panel may result in a height dimension taller than what we specify This can be achieved provided the additional height is positioned above the appliance door NOTICE The integrated panel aligns with the surrounding cabinetry and due to differences in cabinetry may not align perfectly with the door The appliance will need up to 34 1 2 876 mm to the underside of the counter to leave room for leveling adjustments A single prepared panel with insert must not weigh more than 20 Ibs 10 kg Integrated Panel Preparation 1 Cut the main panel to the dimensions below For details see the drawings on the next page ERATING INSTRUCTIONS e MAINTENANCE e SERVIC Main panel width Main panel height 17 1 2 445 mm 28 13 16 732 mm 2 Create the top design for the handleless feature and the 1 8 3 mm notch for the insert s indicated on the Top Detail drawing on the next page 3 Prepare the insert s that will back up the handleless design Wooden Insert Cut 1 8 3 mm thick wooden insert s to the dimensions below Wooden insert width 17 1 2 445 mm Wooden insert height 3 1 2 89 mm a Wooden Insert kK Top Design and Insert Notch x Main Panel Integrated Panel 4 Optional Stain or finish panel and wooden insert to desired stain or color Be sure to closely
17. sound like boiling liq owing through an evaporator uid Condenser Fan Air movi be heard ng through a condenser may Solenoid Valves An occasional clicking sound may be heard as solenoid valves are operated TROUBLESHOOTING GUIDE A DANGER ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the unit before disconnecting the main electrical power Troubleshooting What to check when problems occur Problem Possible Cause and Remedy Digital Display Ensure power is connected to the unit and Light Do If the unit is cooling it may be in Sabbath ot Work mode nterior Light If the unit is cooling it may be in Sabbath Does Not mode or manually set to off Illuminate Light Remains Lighting may be set to on reset to with door on When Door s Closed Unit Develops The unit is exposed to excessive humidity Condensation oisture will dissipate as humidity levels on External decrease Surfaces Digital Display Ensure the unit is not in Showroom Mode Functions But Momentarily unplug or interrupt power supply Unit Does Not to the unit Produce Ice Digital Display Door indicates the door may be opened too Shows an ong Ensure the door is closing properly For Error other error codes contact U Line Customer Service Ice Is Too ce Adjust not set to user s preference Adjust Thick Thin ice thickness via Customer
18. the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Adjust the front legs to level the unit after it is correctly positioned in the opening INSTALLATION 1 Plug in the power electrical cord 2 Gently push the unit into position Be careful not to entangle the cord or water and drain lines 3 Re check the leveling from front to back and side to side Make any necessary adjustments The unit s top surface should be approximately 1 8 3 mm below the countertop 4 Install the anti tip bracket 5 Remove the interior packing material and wipe out the inside of the unit with a clean water dampened cloth General Installation 1 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP Integrated Panel Dimensions INTEGRATED PANEL NOTICE Due to differences in surrounding cabinetry the panel may not perfectly align with door The procedure below is designed to provide a finished integrated panel that seamlessly integrates with surrounding cabinetry Panel Preparation A full integrated door panel completely covers the door frame and provides a built in appearance NOTICE The door panel must not weigh more than 20 Ibs 10 kg It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when ha
19. Drawer h Align Panel lt Against Door Drawer Edge First ERATING INSTRUCTIONS MAINT NOTICE NANCE e S RVIC Due to differences in floor construction or surrounding cabinetry the panel may not sit flush with the top of the door drawer Panel y Door 6 Secure integrated panel to door drawer using clamps A robust tape may also be used U Line recommends the use of bar clamps to secure the panel to the door drawer If using tape be certain the tape will not damage panel finish upon removal 7 Using a 7 64 3 mm drill bit drill 6 pilot holes into the wood panel Bar Clamp Door Drawer Wood Panel Bar Clamp 1 2 12 mm deep using the holes in the door frame as a guide NOTICE It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardwood is installed 8 Locate 6 of the 6x 1 1 2 38 mm screws provided with your unit Integrated Panel Installation 1 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINTENANCE SERVIC 9 Using a Phillips screwdriver place one screw into each of the 6 pilot holes and screw down Do not overtighten Screws 10 Be sure the screws force their way past the opening on the gasket chann
20. GRAVITY DRAIN Normal Proper Drain With Trap Poor Drainage Water Will Back Up With Trap and Vent Proper Drain A gravity drain may be used if Drain line has at least a 1 drop per 48 approximately 2 cm drop per 100 cm of run Drain line does not create traps and is vented per local code Cut the pre installed drain tube to length Connect to your local plumbing per the local code If necessary insulate drai condensation n line to prevent Test the drain system per the test procedure under Final Installation Failure to connect water supply or drain line connections properly can result in personal injury and property damage Gravity drain connections must be routed downward from the rest of the unit at the rate of 1 4 per foot 1 cm per 50 cm Drain 1 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP FACTORY INSTALLED DRAIN PUMP If your drain line will run up to a stand pipe disposal or spigot assembly or does not otherwise meet the requirements for a gravity drain you may have ordered a pre installed U Line P60 drain pump If you need to install a P60 drain pump into your unit see Drain Pump See below for typical installations requiring a drain pump Stand Pipe P60 Pump Required gt i Jon Waste Shut Off
21. L Pe 7 Airflow and Product Loading 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP Cleaning EXTERIOR CLEANING Stainless Models Stainless door panels and handles can discolor when exposed to chlorine gas pool chemicals saltwater or cleaners with bleach Keep your stainless unit looking new by cleaning with a good quality all in one stainless steel cleaner and polish monthly For best results use Claire Stainless Stee Polish and Cleaner which can be purchased from U Line Corporation Part Number 173348 Comparable products are acceptable Frequent cleaning will remove surface contamination that could lead to rust Some installations may require cleaning weekly Do not clean with steel wool pads Do not use stainless steel cleaners or polishes on any glass surfaces Clean any glass surfaces with a non chlorine glass cleaner Do not use cleaners not specifically intended for stainless steel on stainless surfaces this includes glass tile and counter cleaners If any surface discoloring or rusting appears clean it quickly with Bon Ami or Barkeepers Friend Cleanser and a nonabrasive cloth Always clean with the grain Always finish with Claire Stainless Steel Polish and Cleaner or comparable product to prevent further problems Using abrasive pads such as ScotchBrite will cause the graining in the stainless
22. NG SOUNDS and TROUBLESHOOTING GUIDE sections below to help you quickly identify common problems and possible causes and remedies Most often this will resolve the problem without the need to call for service IF SERVICE IS REQUIRED If you do not understand a troubleshooting remedy or your product needs service contact U Line Corporation directly at 1 800 779 2547 When you call you will need your product Model and Serial Numbers This information appears on the Model and Serial number plate located on the interior of your product or can be accessed through Help in the Customer Menu NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components Despite this technology your model may make sounds that are unfamiliar Normal operating sounds may be more noticeable because of the unit s environment Hard surfaces such as cabinets wood vinyl or tiled floors and paneled walls have a tendency to reflect normal appliance operating noises Listed below are common refrigeration components with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed NANC e SERVICE ERATING INSTRUCTIONS MAINT Compressor The compressor makes a hum or pulsing sound that may be heard when it operates Evaporator Refrigerant f may
23. TS EE p z Water trough 6 Clean the Interior Bin as follows Dilute one packet of CLR cleaner into two quarts of water Using a sponge or cloth clean interior of ice bin tubing and door This cleaner will remove all mineral deposits and other contaminants from the surfaces Using a bottle brush clean out the trough drain tube and pump tubing where needed e e o Ww a BOA 7 Switch on unit on by pressing 8 Place unit in cleaning mode See CONTROL OPERATION for more detail Cleaning 2 USER GUIDE U LINE u line com SAF ETY e INSTALLATION amp INT 9 When water begins flowing over the evaporator approximately 3 minutes pour 1 packet of CLR cleaner into the water trough The cleaning process will last approximately 45 minutes 10 Dilute 1 tablespoon 15 ml bleach in 1 gallon 3 8 liters of warm water Apply this solution to the entire inside of the storage area Then rinse thoroughly with water The unit will resume operation approximately 15 minutes after the automated cleaning process is completed The water fill valve will energize fill the water reservoir and shut off after three minutes The com
24. TY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINTENANCE e SERVIC 4 Turn on water and check for leaks 5 Route water supply line in cable clamp and secure with screw Water Hookup 2 USERAGUIDE LINE u line com U SAF ETY e INSTALLATION amp INTEGRATION OP Drain Models ending in O0A 01A will not be equipped with factory installed drain pump Models ending in 40A 41A will have the factory installed drain pump DRAIN CONNECTION If your U Line unit did not come with a factory installed drain pump you must use a gravity style drain connection For assistance in determining if your unit has a pump please contact U Line The floor drain must be large enough to accommodate drainage from all attached drains Follow these guidelines when installing drain lines to prevent water from flowing back into the ice maker storage bin and or potentially flowing onto the floor which may result in personal injury or property damage NOTICE Drain can NOT be located directly below the unit Unit has a solid base that will not allow the unit to drain below itself There is a possibility that hose connections may have loosened during shipment Verify all connection and fitting are free from leaks NANC e SERVIC ERATING INSTRUCTIONS MAINT
25. USER GUIDE SAF ETY e INSTALLATION amp INT U LINE RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 1962 Modular 3000 Series EGRATION e OP e 3018CLR ERATING INSTRUCTIONS e MAINT NANC RVIC 18 Clear Ice Machine USER GUIDE LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC Contents Intro Maintenance Safety Cleaning Safety and Warning Cleaning Condenser Disposal Extended Non Use Installation Service Environmental Requirements Accessories Electrical Troubleshooting Cutout Dimensions Warranty Product Dimensions Side by Side Installation Water Hookup Drain Drain Pump Anti 1 Gene Integ Integ Integ Grille Door Door Door Tip Bracket ral Installation rated Panel Dimensions 3 rated Grille Plinth Dimensions rated Panel Installation Plinth Installation Swing Stop Adjust Operating Instructions First Use Control Operation Ice Sabbath Mode Airflow and Product Loading USER GUIDE U LINE u line com WELCOME TO U LINE Congratulations on your U Line purchase Your product comes from a company with over five decades and three generations of premium modular ice making refrigeration and wine preservation experience U Line continues to be the American leader delivering versatility and flexibility for m
26. cle through each available timer setting Selections include On With Door On 3 Hours On 6 Hours or On 24 Hours 4 To exit press or simply wait for the menu to time out CUSTOMER MENU The 3000 Series of U Line undercounter refrigeration appliances contains a feature rich customer menu The Customer Menu allows access to a series of advanced features including Energy Saver Mode Sabbath Mode actual temperature readings as well as a method to restore factory defaults Control Operation 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC 3000 Series Customer Menu Up Select GBA 4 WELCOME TO THE CUSTOMER MENU USE UP DOWN ARROWS TO U LINE SCROLL SETTINGS uy ae w Down 1 To access the Customer Menu hold for 5 seconds 2 Press B or amp to scroll through available selections 3 Press to enter selected sub menu 4 To exit Customer Menu press to scroll to the bottom of the display and press to select Exit Actual Temps Up Select ae TO MENU ACTUAL TEMPS BIN TEMP 1 6 COND TEMP 45 5 U LINE ae fa Can be displayed in Celsius Down The Actual Temps option displays the actual temperature of the ice bin and condenser as well as ambient temperature 1 To view actual temperature press and selec
27. d location for drain water line and receptacle is in adjacent 5 8 cabinet 16 mm lt 17 3 4 gt 450 mm Cutout Dimensions 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINTENANCE e SERVIC 24 610 mm Product Dimensions Includes 3 4 20 mm Integrated Panel 33 11 16 to 34 11 16 856 mm to 881 mm 8 3 5 8 to 4 5 8 92 mm to 118 mm mE 17 3 4 450 mm Product Dimensions 1 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP Side by Side Installation OTHER SITE REQUIREMENTS Side by Side Installation Units must operate from separate properly grounded electrical receptacles placed according to each unit s electrical specifications requirements Cutout width for a side by side installation is the total of the widths listed under Cutout Dimensions in each unit s Installation Guide Each door can be opened individually one at a time without interference However to ensure unobstructed door swing opening both doors at the same time 1 4 6 4 mm of space needs to be maintained between the units j 1 4 6 mm
28. d through this menu Once the cleaning cycle starts the cycle cannot be stopped until complete To initiate a clean cycle select Clean Cycle from the Customer Menu Please refer to CLEANING section regarding proper cleaning procedure 1 Press to select Clean Cycle 2 Press The clean cycle will now begin 3 Refer to CLEANING section regarding proper cleaning procedure Silent Mode 4 RETURN TO MENU SILENT MODE gt SILENCE Users can halt ice production for 3 hours with an option called Silent Mode in the Customer Menu Silent Mode will begin once the current ice making cycle is complete After 3 hours in Silent Mode normal ice production will continue NOTE Silent Mode will not silence any alerts To initiate Silent Mode enter Silent Mode Menu from within the Customer Menu To activate Silent Mode 1 Press amp to select Silence 2 Press Silent Mode will now begin To cancel Silent Mode 1 Press to select Cancel 2 Press Silent Mode will end Ice Adjust Up RETURN TO MENU ICE ADJUST gt ICE ADJUST 0 6 U LINE H Down The Ice Adjust option adjusts ice thickness by adding or subtracting up to 5 minutes of ice production To change the ice thickness enter the Ice Adjust Menu from within the Customer Menu To adjust thickness 1 Press to s
29. e sure the door gasket is not pinched on the hinge side of the door Do not attempt to use the door to raise or pivot your unit This would put excessive stress on the hinge system If door being adjusted houses the display unit remove cable from display by pressing in the release tab on the cable connector Press Tab Down ERATING INSTRUCTIONS MAINT NANC e SERVIC Alignment and Adjustment Procedure 1 Remove integrated panel if installed Using a T 25 Torx Bit loosen each pair of Torx head screws on both the upper and lower hinge plates Square and align door as necessary Tighten Torx head screws on hinge If necessary re connect display T 25 Torx Screw T 25 Torx Screw Door Adjustments 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION e OPERATING INSTRUCTIONS MAIN First Use All U Line controls are preset at the factory Initial startup requires no adjustments NOTICE U Line recommends discarding the ice produced during the first two to three hours of operation to avoid possible dirt or scale that may dislodge from the water line When plugged in the unit will begin operating under the factory default setting Follow the on screen prompt for language selection and temperature units To turn the unit off press and hold for 5 seconds and release The
30. e the clamp for pump installation To prevent damage to the pump leave sufficient space between leveling leg and pump ERATING INSTRUCTIONS MAINT NANC e SERVIC Note Slide clamp on hose end before installing hose Do not tighten clamp until pump and hoses have been installed 4 Install the 3 hoses and hose clamps to the pump assembly as shown below Do not tighten clamps at this time Drain Tube f Vent Tube Remove the protective paper from the adhesive strip and carefully set pump inside of unit Unplug jumper block from ice machine wiring harness jumper block has a single pink wire Discard jumper block Jumper Block Connect pump wiring plug to the ice machine wiring harness connector where the jumper block was removed The connector is keyed and can only be inserted one way Drain Pump 2 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINTENANCE e SERVIC 8 Route the vent tube up Ye the back of the unit next to the insulated tubes When working with tools inside of unit be Secure vent tube vertical careful so as not to nick or damage any to the insulated tubes refrigerant lines pipes or wires using plastic tie wraps Connect pump drain tube to storage bin drain nipple with clamp removed from oO The back pan
31. el and sit flush against the bottom of the channel i Integrated Panel Integrated Panel A 11 Remove clamps from door NOTICE If panel requires additional adjustment after removing clamps slightly loosen each screw and adjust panel as necessary Tighten screws upon completion Do not overtighten screws bulges in plastic frame might be visible if tightened too much 12 Starting at the corners re install the gasket into the gasket channel in the frame Make sure the gasket is fully seated This may take some force Integrated Panel Installation 2 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP Grille Plinth Installation REMOVING AND INSTALLING GRILLE PLINTH STRIP BASE FASCIA Disconnect electrical current to the unit before removing the grille plinth strip base fascia Edges of sheet metal may be sharp Removing the grille plinth strip base fascia 1 Disconnect electrical current to unit 2 Using the included 7 64 Allen wrench loosen but do not remove both grille plinth strip base fascia lock screws See below a Grille Mounting Screws 3 Gently pull grille plinth strip base fascia away from unit until it stops 4 Push grille plinth strip base fascia rails towards the center of the unit to lift rails off lock screws LJ
32. el serves as a guard Do not put step 3 Ensure that no your hands inside the ice machine cabinet or kinks are present in the attempt to touch any components except the tube discharge tube during testing 10 Tighten the clamps on the drain discharge and vent tubes with a screwdriver or 1 4 nut driver Failure to properly secure the vent tube will result in water damage to the unit and surrounding areas Do not allow vent tube to kink bend or be obstructed in any way Note The discharge tube will need to be trimmed Cut back the tube MAX of 1 4 on each end so that no kinks are formed in drain tube Vent tube must be straight and parallel to insulated tubes Do not over tighten the plastic tie wraps Over tightening can pinch vent tube closed or cut into insulation Drain Pump 3 USERAGUIDE LINE u line com U SAF ETY e INSTALLATION amp INTEGRATION OP Anti Tip Bracket The the anti tip bracket must be installed to prevent unit from tipping when doors are fully opened or excess weight is placed on the front of the unit The anti tip bracket has multiple mounting options Mounting will depend on your particular cabinet configuration Follow the instructions below to secure the anti tip plate to the unit Locate your anti tip bracket and 5 8x5 8 screws included with your unit TOP MOUNT Top mount configurations work well wi
33. elect Ice Adjust 2 Press The selection will begin to flash 3 Press B to make the ice thicker or amp to make the ice thinner 4 Press to confirm your choice Control Operation 4 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION e OPERATING INSTRUCTIONS MAINI Help Up Select gt RETURN TO MENU Help Model 3018CLR 1 800 779 2547 amp U LINE Down To access the Help Menu select Help from the Customer Menu Press B or amp to scroll through available information To return to the Customer Menu press B to select Return to Menu and press to confirm NANCE e SERVIC Control Operation 5 USER GUIDE U LINE u line com SAFETY Ice ICE CUBE NOTICE INSTALLATION amp INTEGRATION e OPERATING INSTRUCTIONS MAINTENANCE SERVIC THICKNESS ADJUSTMENT Ice thickness adjustment should only be made one increment at a time Allow ice maker production to stabilize for 24 hours before rechecking ice thickness Remove al ice from the storage bin Ice cubes in any given batch will vary so it is necessary to choose cubes from the sample area for comparison when making adjustments The ice cube thickness is factory set for best overall performance The factory setting 0 is designed to maintain an ice bridge of approximately 1 16 to 1 8 1 6 m
34. follow the instructions provided by the manufacturer NOTICE If finishing panel or wooden insert all sides must be finished to prevent warping 5 Attach the insert to the panel Wood glue or equivalent adhesive should be used to attach insert to panel Attach Wooden Insert Integrated Panel Dimensions 2 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINTENANCE e SERVIC Handleless Integrated Panel Dimensions 1 8 3 mm gt lt y s Top Design 1 4 6 mm A 7 8 22 mm Ref y 2 3 8 60 mm 17 1 2 gt 445 mm i Y X Insert Notch gt lt Wooden Insert Notch Depth 1 8 3 mm Top Detail gt lt 3 4 20 mm Wooden Insert Dimensions He 17 1 2 445 mm gt gt lt 1 8 3 mm F som 89 mm ye Integrated Panel Dimensions 3 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINTENANCE e SERVIC EXTENDED INTEGRATED PANEL NOTICE Due to differences in surrounding cabinetry the panel may not perfectly align with door The procedure below is designed to provide a finished panel that seamlessly integrates with surrounding cabinetry Panel Preparation An extended integrated panel can be used to maintain alignment with an adjacent extended cabinet height or a
35. followed In addition P60 drain pumps in clear ice m according to the followi 1 Remove the drain p Ng 2 Drain the water in t pump upside down and achines must be drained procedure ump from the ice machine allowing the water to drain through the pump s inlet and vent tube fittings 3 After water is drained reinstall the drain pump and reattach all connections ERATING INSTRUCTIONS MAINTENANCE SERVIC For questions regarding winterization please call U Line at 1 800 779 2547 Damage caused by freezing temperatures is not covered by the warranty Do not put anti freeze in your unit he pump s reservoir by turning the Extended Non Use 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION e OPERATING INSTRUCTIONS MAINTENANCE SERVICE Accessories 80 5 1002 00 23054 01 Accessories Clear Ice Accessories Clear Ice Accessories Stainless Steel Maker Refresh Kit Machine Cleaner 1 Box of PRO Style Door Handle US 98 99 6 packets 1 1 4 in diameter US 39 00 US 49 00 Accessories 1 USER GUIDE LINE u line com U ETY e INSTALLATION amp INT SAF EGRATION OP Troubleshooting BEFORE CALLING FOR SERVICE If you think your U Line product is malfunctioning read the CONTROL OPERATION section to clearly understand the function of the control If the problem persists read the NORMAL OPERATI
36. ightning damages incurred or resulting from shipping improper installation unauthorized modification or misuse abuse of the product customer education calls food loss and spoilage door and water level adjustments except during the first 30 days from the date of installation defrosting the product adjusting the controls door reversal and cleaning the condenser U Line product are designed to operate in ambient temperatures between 50 F and 100 F unless otherwise noted in the product manual Exposure to temperatures outside this range may cause degradation of performance and issue such as lower ice production or spoiled contents are not covered under the terms of this warranty as a result of that exposure U Line product may not be subjected to temperatures below 40F without following the winterization and vacation shutdown procedures in the user guide U Line s Outdoor Limited Warranty set forth in this Paragraph 6 shall apply to U Line models deemed suitable for outdoor use by Underwriters Laboratory UL as noted in the U Line Product Catalog U Line s website and or on the serial tag located inside the product A Outdoor product may come into contact with rain by virtue of outdoor use Exposure to other sources of water shall also cause this warranty to be void including flooding of the area in proximity of the unit greater than 1 8 deep in water hurricanes splashing of pool water or directing a spra
37. in Your unit s door s will open 115 straight from the factory If you would like the door stop at 90 follow these instructions NOTICE If your unit is already undercounter it will need to be moved out to access the hinge With the 90 stop pin in place you will not be able to replace the hinge cover 1 Open door approximately 90 4 To fully seat the pin tap it lightly with a hammer 5 Carefully slide your unit back in place NOTICE The pin can be removed to return the door swing back to its original 115 swing by tapping the pin out from the bottom of the hinge 2 Remove hinge cover by lifting top and bottom of hinge CLOSER cover and sliding the cover inwards to remove from The door hinge has a self closing feature that engages hinge when the door is open approximately 6 150 mm about 25 Door Stop 1 USERAGUIDE LINE u line com U SAF ETY e INSTALLATION amp INTEGRATION OP Door Adjustments DOOR ALIGNMENT AND ADJUSTMENT Align and adjust the door if it is not level or is not sealing properly If the door is not sealed the unit may not cool properly or excessive frost or condensation may form in the interior NOTICE Properly aligned the door s gasket should be firmly in contact with the cabinet all the way around the door no gaps Carefully examine the door s gasket to ensure that it is firmly in contact with the cabinet Also mak
38. m to 3 2 mm under normal conditions resulting in a dimple of approximately 1 4 to 1 2 6 4 mm to 12 7 mm i results in a n depth A fuller cube with less of a dimple thicker ice bridge As the ice bridge thickens the tendency for the cubes to stay together as a slab increases A bridge thicker than 1 8 3 2 mm may cause cubes to overfill the ice bucket ICE BRIDGE DIMPLES Ice Bridge and Dimples Your clear ice machine is pre set to produce ice between the optimal dimensions illustrated below Cube Types 1 4 TO 1 2 1 16 TO 1 8 6 4 mm to 12 7 mm 1 6 mm to 3 2 mm DIMPLE ICE BRIDGE THIN BRIDGE THICK BRIDGE LITTLE OR DEEP DIMPLE NO DIMPLE _ l l LJ Ice 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION e OPERATING INSTRUCTIONS MAIN ICE ADJUST Up Select RETURN TO MENU ICE ADJUST amp U LINE N gt ICE ADJUST 0 Down Adjust ice thickness as follows 1 Press 4 and and hold for 5 seconds to enter the Customer Menu 2 Press amp to select Ice Adjust 3 Press The selection will begin to flash 4 Press 4 to make the ice thicker or amp to make the ice thinner Press to confirm your choice The total range of adjustment is 5 thinest to 5 thickest If further adjustments are desired repeat Steps 1 through 4
39. oduct contact a licensed plumber Water Supply Connection Review obey and understand the local plumbing codes before you install your unit Connect to the cold water supply The water pressure should be between 20 and 120 psi 138 and 827 kPa The water line MUST have a shut off valve on the supply line ERATING INSTRUCTIONS e MAINTENANCE SERVIC Do not use any plastic water supply line The line is under pressure at all times Plastic may crack or rupture with age and cause damage to your home Do not use Teflon tape or joint compound on the water fitting The rubber washer provides an adequate seal Other materials could cause blockage of the valve Failure to follow recommendations and instructions may result in damage and or harm flooding or void the product warranty Turn off water supply and disconnect electrical supply to unit prior to installation 1 Turn off water supply and disconnect electrical supply to product prior to attempting installation 2 Locate the desired cold water supply location 3 Locate braided stainless steel water supply line and connect to your cold water supply The water line should be looped into 2 coils This will allow the unit to be removed for cleaning and servicing However make certain that the tubing is not pinched or damaged during installation Water Hookup 1 USER GUIDE U LINE u line com SAFE
40. pressor begins to operate and water flows over the evaporator assembly ice mold Initially the water flow may not be uniform causing uneven sized cubes or water to spill into the ice storage bin This is a normal situation that will correct itself within the first 24 hours of operation NOTICE Discard all ice produced in the first harvest Should power to the unit be interrupted during the self clean cycle the complete cleaning cycle will repeat after power is restored REFRESH KIT Due to variations maintenance your unit may become excessively coated in lime scale or calcium U Line offers a cost effective refresh kit which replaces many interior components and will return your unit to like new condition Refresh kits may be ordered from your local distributor and installed by your local service company For information on your local distributor or service company please visit www u line com in water quality or inadequate EGRATION e OP ERATING INSTRUCTIONS MAINTENANCE S RVIC Cleaning 3 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINTENANCE SERVIC Cleaning Condenser INTERVAL EVERY SIX MONTHS To maintain operational efficiency keep the front grille plinth strip base fascia free of dust and lint and clean the condenser when necessary Depending on environmental conditions more or le
41. rdware is installed 1 Cut the panels to the dimensions listed in the diagram below 2 Optional Stain or finish panel to desired stain or color Be sure to closely follow the instructions provided by the manufacturer 3 Optional Install handles and hardware NOTICE When applying an integrated panel to a unit ensure that both sides are finished in order to prevent warping In some panel installations the panel may be visible through the glass while the door is open ERATING INSTRUCTIONS e MAINTENANCE SERVIC Integrated Panel Dimensions BACK SURFACE MUST HAVE AMPLE FLAT SURFACE TO MOUNT OVERLAY PANEL FLAT AND WITHOUT INTERFERENCE 3 4 y 20 mm 17 1 2 kK 445 mm gt A 30 762 mm Integrated Panel Integrated Panel Dimensions 1 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP HANDLELESS INTEGRATED DOOR PANEL The following procedure is designed to provide a finished handleless solid panel for an 18 450 mm door that seamlessly integrates with its surrounding cabinetry NOTE Many cabinet manufacturers provide a ready solution for a handleless integrated design that can be easily applied to your U Line 3000 Series model Consult your cabinet manufacturer for applicable design and installation details The cabinet manufacturer s solution to this design and integration detail will often
42. rille E plinth strip base fascia height 2 Finish or stain your grille plinth strip base fascia panel to match your surrounding furniture Finish J i front back and edges to prevent warping Carefully E E follow the manufacturer s recommendations for finish 8 aS application and cure times 3 Apply double sided tape to the backside of the integrated grill plinth strip base fascia Use the diagram below for reference U Line recommends 3M VHB tape a high strength bonding tape sek e Y Apply Tape To Shaded Area 4 Remove backing paper from double sided tape 5 Carefully align grille plinth strip base fascia over integrated panel and press into position Integrated Grille Plinth Dimensions 1 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP Integrated Panel Installation 1 Fully open door drawer _ gt 2 Starting at corner pull gasket away from door 3 Continue to pull gasket free from gasket channel 4 Upon removal lay gasket down on a flat surface NOTICE If the door drawer houses the display make certain the display cable remains securely seated in the inner door channel see below Display Inner Door Cable Channel X 5 The panel should be aligned with the outside edge opposite the hinge and high enough to align with the highest point in the door drawer Align Top Of Panel With Highest Point Of Door
43. s English will begin to flash 4 Press B or amp to cycle through the available languages 5 Press to confirm your choice Sound Level Up Select amp p m G U LINE amp e High Down Audible alarms and alert tones support four different Sound Level settings High Medium Low and Off To select a new tone level enter the Sound Level Menu from the Customer Menu 1 Press B or amp to select the current sound level 2 Press The current setting will begin to flash 3 Press B or amp to select a different level 4 Press to confirm your choice Fahrenheit Celsius Up Select RETURN TO MENU FARENHEIT CELSIUS 6 U LINE DEGREES F JS BGA Down Temperature and set point information can be displayed in either Fahrenheit or Celsius To change from Fahrenheit to Celsius enter the Fahrenheit Celsius Menu from within the Customer Menu 1 Press to select Degrees 2 Press The selection will begin to flash 3 Press B or amp to select between F Fahrenheit or C Celsius 4 Press to confirm your choice Control Operation 3 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC Clean Cycle RETURN TO MENU CLEAN CYCLE gt CLEAN Down A clean cycle can be initiate
44. ss frequent cleaning may be necessary Disconnect electric current to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condenser unit Condenser may be cleaned using a vacuum soft brush or compressed air 1 Remove the grille plinth strip base fascia See GRILLE PLINTH INSTALLATION 2 Clean the condenser coil using a soft brush or vacuum cleaner 3 Install the grille plinth strip base fascia Condenser Cleaning Condenser 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION e OP Extended Non Use VACATION HOLIDAY PROLONGED SHUTDOWN The following steps are recommended for periods of extended non use 1 Remove all consumable content from the unit 2 Disconnect the power cord from its outlet socket and leave it disconnected until the unit is returned to service 3 Turn off the water supply 4 If ice is on the evaporator allow ice to thaw naturally 5 Clean and dry the interior of the cabinet Ensure all water has been removed from the unit 6 Disconnect the water and drain line if applicable making sure all water is removed from the lines 7 The door must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be exposed to temperatures of 40 F 5 C or less the steps above must be
45. steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible ERATING INSTRUCTIONS MAINTENANCE e SERVIC Integrated Models To clean integrated panels use household cleaner per the cabinet manufacturer s recommendations INTERIOR CLEANING Disconnect electric current to the unit Clean the interior and all removed components using a mild nonabrasive detergent and warm water solution applied with a soft sponge or non abrasive cloth Rinse the interior using a soft sponge and clean water Do not use any solvent based or abrasive cleaners These types of cleaners may transfer taste to the interior products and damage or discolor the lining CLEAR ICE MAKER CLEANING CYCLE The 3000 series ice maker is equipped with an automatic clean alert function Cleaning cycles should be run as notified Otherwise to maintain operational efficiency the unit should be cleaned every three months Depending on water conditions more frequent cleaning may be necessary If the ice maker requires more frequent cleaning consult a plumber to test the water quality and recommend appropriate treatment Wear rubber gloves and safety goggles and or face shield when handling Ice Machine Cleaner NOTICE Discard all ice produced in the first harvest Should electricity to the unit be interrupted during the self clean cycle
46. t Actual Temps from the Customer Menu 2 Press B or amp to scroll through available information 3 To return to the Customer Menu press and select Return to Menu Energy Saver Mode Up Energy Saver Mode Indicator Select t Ske U LINE 12m remaining Down Energy Saver mode reduces overall energy consumption by reducing the amount of ice stored in the bin along with decreasing the lighting 1 To enter Energy Saver Mode first select Energy Saver from the Customer Menu 2 Press amp to select Off in the menu w 3 Press 4 Press B or amp to change the selection from Off to On 5 Press to confirm your selection ec 6 To return to the Customer Menu press amp and select Return to Menu 7 To cancel Energy Saver Mode simply return to the Customer Menu select Energy Saver and change On to Off Control Operation 2 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVIC Languages LANGUAGES gt ENGLISH B RETURN TO MENU E 7 Down The U Line 3000 Series of models supports a number of display languages including English Spanish French German and Italian 1 To change display language select Languages from the Customer Menu 2 Press to select English 3 Pres
47. t may be manually adjusted to the height of your floor Simply raise or lower the skirt as needed Grille Plinth Installation 1 USERAGUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP Door Swing For Integrated models that are installed adjacent to a wall 1 4 6 mm clearance is recommended from wall on hinge side to allow the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated panel frame Stainless Steel models that are installed adjacent to a wall require 2 1 4 57 mm door clearance on hinge side to allow for door handle Units have a zero clearance when installed adjacent to cabinets ERATING INSTRUCTIONS e MAINTENANCE e SERVIC Wall 1 4 6 mm le 90 Door Swing Space i For any Knobs or Pulls Integrated 2 1 4 MIN 57 mm MIN Wal 90 Door Swing Stainless Door Swing 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OPERATING INSTRUCTIONS e MAINTENANCE e SERVIC Door Stop 3 Once cover is removed slide hinge pin into hole as shown Pin should slide into place stopping the door at Your U Line unit was shipped to you with the optional 90 90 if the pin does not go into the hole shown hold pin the door less than 90 open and try aga
48. tact Customer circuit open Care Zone T Short Left or right zone Contact Customer thermistor circuit Care shorted NANC e SERVICE Troubleshooting 2 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION OP Warranty U LINE CORPORATION LIMITED WARRANTY 1 U Line Corporation U Line warrants each U Line product to be free from defects in materials and workmanship for a period of one year two years on Modular 3000 Series from the date of purchase U Line further warrants the sealed system consisting of the compressor condenser evaporator hot gas bypass valve dryer and connecting tube in each U Line product to be free from defects in materials and workmanship for a period of five years from the date of purchase During the initial one year warranty period two years on Modular 3000 Series for all U Line products U Line shall 1 repair any product or replace any part of a product and 2 for all Marine RV and Domestic U Line products sold and serviced in the United States including Alaska and Hawaii and Canada U Line shall be responsible for the labor costs performed by a U Line authorized service company incurred in connection with the replacement of any defective part During years two through five of the warranty period for the sealed system U Line shall 1 at U Line s option repair or replace any part of the sealed system
49. th fully secured wood or laminate countertops 1 Align the bracket on top of your unit as shown above The bracket must be used to ensure a secure mount Using 2 of the supplied 8x5 8 screws install screws into the plate using a 2 Phillips head screwdriver Completely slide the unit into its position in the cabinet Be certain unit height is properly adjusted See GENERAL INSTALLATION Open door completely Make certain door clears surrounding cabinetry ERATING INSTRUCTIONS MAINT 5 6 NANC e SERVIC Using a 3 32 drill bit drill 3 pilot holes 5 8 16 mm deep into bottom of countertop Use the anti tip bracket as a template Install the 3 remaining 8x5 8 screws into the plate using a 2 Phillips head screwdriver SIDE MOUNT Left Hinged Cabinet Right Hinged Cabinet Side mount configurations work well if you have a granite countertop or do not wish to mount the bracket to the underside of your countertop Align the bracket to the hinge side of the unit as shown above Using 2 of the supplied 8x5 8 screws install screws into the plate using a 2 Phillips head screwdriver Completely slide the unit into its position in the cabinet Be certain unit height is properly adjusted See GENERAL INSTALLATION
50. the complete cleaning cycle will repeat after electricity is restored Cleaning 1 USER GUIDE U LINE u line com SAFETY e INSTALLATION amp INTEGRATION OP Use only U Line Ice Machine Cleaner Part No 37050 available from your dealer or direct from your local parts distributor To locate a parts distributor near you visit www u line com It is a violation of federal law to use this solution in a manner inconsistent with its labeling Use of any other cleaner can ruin the finish of the evaporator and will void the warranty Read and understand all labels printed on the package before use U Line Ice Machine Cleaner is used to remove lime scale and other mineral deposits Refer to the following steps to initiate the self cleaning cycle Never use anything to force ice from the evaporator Damage may result 1 Switch the ice maker off and allow any ice to melt off of the evaporator Evaporator cover 2 Remove all ice from the storage bin 3 Remove evaporator cover 4 Remove the standpipe by lifting it up while using a Slight back and forth motion to loosen it from the drain hole The water in the reservoir will flow down the drain ERATING INSTRUCTIONS MAINTENANCE S 5 Re install the standpipe RVIC into the water trough Li E
51. ther express or implied if the P60 00 drain pump is used on another ice machine or product for which it is not UL recognized or listed e Modification of the P60 00 drain pump will void all warranties NOTICE Keep your proof of purchase for warranty purposes u line com ERATING INSTRUCTIONS e MAINTENANCE e SERVIC INCLUDED IN KIT 1 1x S shaped Drain Tube 2 1x Straight Drain Tube Not used 3 1x Vent Tube so 4 1x Braided Discharge Tube Not included in pump kit 2x Vent tube Zip Ties 2X Small Worm Gear 1x Large Worm Gear 1x P60 Pump Ice Machine ships with discharge tube installed Clamps Clamp 1x Discharge Tub Used on older models only TOOLS REQUIRED 1 4 x 6 Blade Screwdriver Adjustable Pliers 1 4 Nut Drive Drain Pump 1 USER GUIDE LINE u line com U SAF ETY e INSTALLATION amp INTEGRATION OP Discharge Tube Connector Drain Tube Connector Vent Tube Connector INSTALLATION PROCEDURE To prevent accidental electrocution make certain that the floor surfaces surrounding the unit are dry whenever power electricity is removed from or applied to the unit 1 Disconnect your unit from its electrical outlet socket Using a screwdriver or 1 4 nut driver remove the 9 screws from the back panel Remove the drain line pipe from the storage bin drain nipple Sav
52. ultiple applications including residential light commercial outdoor and marine use U Line s complete product collection includes modular Wine Captain Models Beverage Centers Clear Ice Machines Crescent Ice Makers Glass amp Solid Door Refrigerators Drawer Models Freezers and Combo Models U Line has captivated those with an appreciation for the finer things with exceptional functionality style inspired innovations and attention to even the smallest details We are Known and respected for our unwavering dedication to product design quality and selection U Line is headquartered in Milwaukee Wisconsin with a west coast office located in Laguna Beach California and European support in Dublin Ireland U Line has shipped product to five continents for over two decades and is proud to have the opportunity to ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Quick Reference Guides CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u line com under Documentation PROPERTY DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U Line product please take the following steps 1 U Line Customer Care must be contacted immediately at 1 800 779 2547 2 Service or repairs performed on the unit without prior written approval from U Line is not permitted If the unit
53. y from a hose or similar device into and around the unit Warranty 1 USER GUIDE U LINE u line com SAFETY INSTALLATION amp INTEGRATION e OPERATING INSTRUCTIONS MAINT 7 If a product defect is discovered during the applicable warranty period you must promptly notify either U Line at 8900 N 55th Street Milwaukee Wisconsin 53223 USA or at 1 800 779 2547 or the dealer from whom you purchased the product In no event shall such notification be received later than 30 days after the expiration of the applicable warranty period U Line may require that defective parts be returned at your expense to U Line s factory in Milwaukee Wisconsin for inspection Any action by you for breach of warranty must be commenced within one year after the applicable warranty period 8 THIS LIMITED WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ALL OF WHICH ARE DISCLAIMED U Line s sole liability and your exclusive remedy under this warranty is set forth in the paragraphs above U Line shall have no liability whatsoever for any incidental consequential or special damages arising from the sale use or installation of the product or from any other cause whatsoever whether based on warranty express or implied or otherwise based on contract tort or any other theory of liability

Download Pdf Manuals

image

Related Search

Related Contents

Torque-Hub® Planetary Final Drive W6 Series Service Manual  SurCode for Dolby® Pro Logic II  Lincoln Electric IM658-A User's Manual    Guía de referencia rápida  "Overview of Receptors from Combinatorial Nucleic Acid and Protein  Clack Water Specialist 1.5 User Manual  2 - Graco  GOMA LACA  Sony VAIO VPCEE23FX  