ADEMCO 61 ADEMCO 6160PX INSTALLATION AND SETUP GUIDE
Contents
1. Reader Address Mode NOTE This mode can be entered only if the green and yellow data wires are disconnected 1 After exiting Keypad Address mode the Prox Reader begins communicating with the Keypad and the Keypad displays Prox Addr XX on the first line cursor will be under the tens digit 1 XX the current ECP Address The Prox Reader T If only the red and black wires are connected press within 5 y address cannot be the same as the Keypad seconds of power up If more than 5 seconds elapses before address Select an address between 01 and 30 QD default address 23 2 pressing the 1 and 3 keys the Keypad automatically N enters Prox Reader Address Mode Make sure you enable the Prox Reader address as a keypad in the control panel After all wires are connected press and hold the 1 and 3 keys within 60 seconds of power up 2 Enter the appropriate address Enter the proper 2 Enter the keypad s address Enter the proper tens tens digit of the address The cursor moves to the digit of the keypad s address The cursor will move to ones digit position Enter the proper ones digit of the ones digit position Enter the proper ones digit of the keypad s address Press to save the displayed address e If only the red and black wires are connected the Keypad now enters Prox Reader address mode e If all wiring is connected the system exits address mode the address Press the k
2. case release snaps at the bottom of the Keypad with the blade of a medium screwdriver then pull that side of the case back away Insert the screwdriver in the side of the Keypad between the front and back case and gently twist to release the side locking tab Repeat for the other side Refer to Figure 1 for location of the case back release snaps and locking tabs NOTE OVE CASE BACK PUSH IN THE TWO MOUNTING 2 Route wiring from the control panel through the opening in SNAPS LOCATED ALONG THE BOTTOM OF THE KEYPAD A the case back AND LIFT UP 3 Mount the case back to a wall or electrical box 4 Wire directly from the Keypad s terminal block to the terminal block on the control panel See Wiring Table below Connect only the red and black Aux Power connections at this time RETAINING gt LOCKING TAB Figure 1 Removing the Case Back 6150 006 VO Wiring Table Do not connect the ECP Data In or Data Out until directed Keypad Control Panel Wire Color A to do so If the keypad s Prox Reader detects the presence AG Data In Green Y of ECP Data In and Out connections during address Aux Pwr GND Black programming mode it will exit to normal mode Aux Pwr Red vY Data Out Yellow NOTE No more than one wire per terminal may be See the control panel s Installation and Setup Guide for connected If daisy cha
3. 4 digit security code To arm or disarm the system present the prox tag at the location ane lt gt ALC of the Proximity Label bulls eye on the front of the keypad The ne tess Bt system beeps to confirm that it is has been armed or disarmed cl Arming if system is disarmed System arms in the AWAY mode Ee DE Disarming if system is armed System disarms and if an alarm HERE occurred alarm sounding is silenced FUNCTION KEYS s160PX 001 V0 Programmable Function Keys The keypad features function keys that may be programmed for panic alarms or other special functions such as macros See the control s instructions for details Wa e Function keys must be held down for at least 2 seconds to activate the programmed function e f functions other than panics are assigned to the Function Keys Equivalent Key Pairs programmable function keys programmed panics A 1 and must be initiated by pressing the programmed key B and palir C 3 and D NONE Function Key Labels A set of adhesive backed labels with some typical function symbols i e fire police personal emergency etc is provided These labels can be placed on or next to the keys to identify each key s function for the end user as determined by the control panel s capability and programming see the control s instructions Keypad Displays and LEDs The Keypad provides a two line alphanumeric LED Funct
4. Honeywell ADEMCO 6160PX AlphaProx Keypad INSTALLATION AND SETUP GUIDE GENERAL INFORMATION The ADEMCO 6160PX is an addressable Remote Keypad with a built in Proximity Reader and is intended for use with ADEMCO control panels Basic features of the Keypad Installation Notes e 2 line Alpha display e The Keypad can only be used on addressable systems e Backlit Display programmable as permanent on and must be set for address 00 30 16 23 for some controls see the control s instructions for VISTA 15P VISTA 20P and VISTA 21iP controls details e The Prox Reader uses an additional keypad address e Continuously Backlit Keys for convenience which must be enabled at the control panel see e Programmable Function Keys control panel installation instructions for allowable e Built in Sounder speaker keypad addresses e Arm Disarm via Prox Tag e The partition used for the Keypad Prox Reader and e LED Indicators for Armed and Ready To Arm user security code must be the same e The Prox Tags will only arm and disarm one partition The Prox Reader cannot be used to perform global arming operations e For optimal performance use only the Prox Tags provided For additional Prox Tags order PROXTG BK Black or PROXTG GY Gray e Supervised by control panel if supported e Uses two keypad addresses MOUNTING AND WIRING The Keypad can be surface mounted directly to a drywall or to a single or double gang electrical box 1 Push the two
5. Melville NY 11747 800 04917V1 4 10 Rev A www honeywell com security
6. ey to save the entry The Keypad beeps three times confirming the address is accepted and the first digit of the address flashes You can re enter the address if needed Power down the Keypad and remove the case back Refer to step 7 of the Mounting and Wiring section and complete the green and yellow wiring connections VIEWING THE KEYPAD ADDRESS During normal operation press and hold down the 1 and 3 keys at the same time for about 3 seconds The current keypad address is displayed No key entry is allowed Press any key to exit or wait 10 seconds to exit viewing mode ENROLLING PROX TAGS Each Prox Tag is enrolled as a User in the alarm system When enrolling the Tags the last four digits of 4p Swiping a Prox Tag when the system is in the Tag s serial number is used as the User Code Refer al programming mode may cause programming fields to to the control s User Guide for instructions on receive invalid entries programming user codes When programming is complete test the system to ensure that each Prox Tag arms and disarms the system as specified KEYPAD OPERATION For detailed system operating instructions refer to the User Guide for the control panel used with this keypad Prox Tag Operation DISPLAY Prox tags are used to alternately arm and disarm the system eS Presenting a prox tag is functionally equivalent to entering a ae a
7. h the four digit serial number located on the tag s packaging 9 90 ND Aw SETTING THE KEYPAD AND PROX READER ADDRESSES The Keypad requires two unique device addresses a Keypad address and a Prox Reader address Addresses range from 00 30 default address is 31 and must be changed to an appropriate address To initially set the addresses make sure that only the red and black wires are connected to the Keypad then follow the steps below for Keypad Address Mode and Prox Reader Address Mode When both the Keypad address and Prox Reader address have been programmed power down the control and complete the wiring connections see step 7 in Mounting and Wiring section After the installation is completed only the keypad address can be changed NOTES e The Prox Reader address can be set only when the green and yellow data wires are disconnected e The keypad will not enter address mode if the panel to which it is connected is in programming mode e If 10 seconds have passed with no key entry the keypad automatically exits address mode You must power down power up and start address mode again e Defaults Keypad address 31 Prox Reader address 23 Keypad Address Mode 1 Enter keypad address mode Power up the Keypad Immediatelyt press and hold down the 1 and 3 keys at the same time for 3 seconds If unable to enter address mode power up and try again The current keypad address is displayed and the Prox
8. ined configuration is required pigtail more complete details wires together so that only one wire is terminated under the screw Use 16 24 AWG wire only 5 Reattach the Keypad to its case back 6 If the Keypad and Prox Reader addresses have not yet been programmed refer to the Setting the Keypad and Prox Reader Addresses section and set the two addresses 7 After the Keypad and Prox Reader addresses have been programmed remove the Keypad from its back plate again see step 1 above and connect the green and yellow data in data out wires from the control 8 Reattach the Keypad to its case back SUMMARY OF PROGRAMMING STEPS 1 Connect only the red and black wires to the Keypad Program the Keypad address 01 31 Press to save Prox Addr XX displays Enter an unused keypad address for the Prox Reader Press to save Power down the panel Connect the green and yellow wires and complete the installation Power up the panel In control panel programming configure the programmed Prox Reader address as a keypad a If using a Vista 128 Vista 50 or like panels go to device programming and program the Prox Address as an Alpha Console b If using a VISTA 15P VISTA 20P use an address between 17 and 23 Go to location 190 to 196 and enter the partition in which the Keypad is being used 10 Exit control panel programming mode 11 Enroll the Prox Tag by programming a new User code wit
9. ion ee m Pe ale The i ARMED Lights red when the system is armed in any mode i a ies the Keypad s s and associate READY Lights green when the system is ready to be armed unctions SPECIFICATIONS Physical 5 5 16 H x 7 3 8 W x 1 3 16 D Displays 2 x 16 alpha numeric supertwist LCD backlit Sounder Speaker fire alarm is loud pulsing single tone burglary alarm is loud continuous dual tone Voltage 12VDC power limited Current 165mA ARMED LED lit LCD backlight and sounder on reduces to 40mA when panel is operating in standby mode backlight off NFPA 72 Compliant REFER TO INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM FEDERAL COMMUNICATIONS COMMISSION FCC PART 15 STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User s Manual Unauthorized changes or modifications could void the user s authority to operate the equipment CLASS B DIGITAL DEVICE STATEMENT NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the in
10. structions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help INDUSTRY CANADA IC STATEMENTS This device complies with RSS210 of Industry Canada Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada Prox Tag User Log Use this form to keep a record of system users and their associated Prox Tag USER AUTHORITY 4 DIGIT TAG NUMBER USER NAME NUMBER LEVEL Tag s User Code 2 Corporate Center Drive Suite 100 oneywell P O Box 9040