User Manual Swiss Garde 3100 IR (26450)
Contents
1. fluores cent lamps electronic ballast etc in order not to overload the internal relay We recommend connecting a maximum of three to four motion detectors in paral lel If the number of switching cycles is above average or in the event of increa sed inductive loads we recommend using the short pulse function on the motion detector and switching the load via an external staircase timer switch or contac tor Wiring diagrams Standard installation Optional push button to remote switch detector for 1 minute by phase interruption power supply to L for 0 5 sec Keep wire as short as pos sible to ensure best results L Bewegungs melder N D tecteur de 1 mouvements Several devices in parallel in short impulse mode max 3 to 4 devices connec ted to a staircase timer switch Minuterie Bewegungs Bewegungs melder melder Treppenhaus 5 f 4 automat D tecteur de D tecteur de mouvements mouvements Detectors connected in parallel with additional wall switch to enable permanent lighting Bewegungs Bewegungs Bewegungs melder melder melder D tecteur de D tecteur de D tecteur de mouvements mouvements mouvements Installation of an RC element between neutral conductor N and switched phase L in case of interferences by fluorescent lamps switch off sparks or by several detectors connected in parallel caused by capacitive current in the wi res Varistor between neutral
2. User Manual 200 Outdoor Motion Detector Swiss Garde 3100 IR 26450 Warning Any work on the main power supply must only be completed by trained specia lists The product must be installed in accordance with installation guidelines stan dards specific to your country Disconnect the 230V power supply before starting the installation process As aprecautionary measure the power supply of the light should always be fit ted with a 250VAC 10A type C fuse in accordance with EN60898 1 Faulty lamps may cause a short circuit and thereby permanently damage the device Disconnect power prior to replacing a lamp To ensure the operational reliability of the detector keep a minimal distance of 1m to lamps installed on the same height level Lamps installed underneath the detector or in the detection area may disturb the functionality Keep the detector away from heating devices In case of malfunction such as continuous lighting or false triggering please refer to the troubleshooting section on page 7 Function The detector reacts to the motion of heat positive or negative in relation to the environment If a person approaches the monitored area the device will turn on the connected light automatically If the person leaves the area the light will be switched off after the preset duration short impulse 10 sec to 20 min The connected light will be turned on only when the ambient light value is below the ad
3. conductor N und phase L to reduce mains voltage peaks Bewegungs melder D tecteur de s4 mouvements Accessory 3 button remote control Functions e AUTO automatic operation default D ON lights permanently ON OFF lights permanently OFF 6 hours duration after which the detector D will go be back to automatic mode ON cannot be activated in short impulse mode Zublin Potentiometer controls overview Red LED flashing once upon detection three times upon adjusting TIME or LUX or receiving a command from the remote control N Accessory P IR remote control EN o on oop O For functions plea se refer to separate P remote control ma nual Attention Manipulating LUX or TIME VR during a stable working condition values will be stored and become valid Any values adjusted by remote control will be overridden Either manual values or values by remote control may be active mixing is not possible SENS sensitivity detection range adjustable by remote control Detection range adjustment max approx 14 m frontal walking person Should the detector be too sensitive triggering without movement in the detection range the sensitivity range can be reduced TIME The timer determines for how long the lights will remain on following the last mo vement in the detection area Choices are between short impulse approx 1 sec approx 20 sec 60 sec break selectable by remote contro
4. justed value Installation The optimal installation height is approx 2 to 5 m Standard mounting height is 2 5 m Wire the detector as follows phase outer conductor L brown neutral neutral conductor N blue switching output switched phase outer conductor L red The detector can be remotely switched for 1 minute by phase interruption po wer supply L for 0 5 sec Should a push button be used that is not installed next to the detector intersper sions may disturb this function Proper functioning is subject to site installation conditions and cannot be guaranteed In case of a disturbed push button function a condensator or an RC element can be connected in parallel L to N The device is operational after approx 1 minute from connecting to mains volta ge After this duration the detector can be programmed either by P IR remote control or by manipulating potentiometers The programming mode needs to be activated by remote control Potentiometer adjustments will only be accepted during a stable working state Important Notice Pointing the detector in the sky can cause faulty detection Potentiometers pointing to the sky are not watertight Connecting electrical loads High inrush currents will considerably shorten the lifetime of the detector s in built relay Please verify the technical data provided by the lamp or luminaires manu facturer concerning inrush currents specifically with compact fluorescent
5. l only and time delay approx 10 30 sec 1 2 6 10 20 min Recommendation approx 2 min in staircases 10 min in restrooms etc LUX twilight sensor The twilight sensor regulates the operating threshold light value of the detector determining when the device should be activated Minimum value 5 lux moon symbol The detector will turn on the light at night Maximum value 2000 lux sun symbol The detector will turn on the light during daytime as well Recommendation approx 5 lux in staircases 200 lux in office spaces Detection range The 200 detection range with 360 creep zone protection as well as the tight de tection area allow for an optimal function The range depends on the installation height and walking direction high sensitivity when cutting or changing a switching segment Since the detector reacts to temperature differences between heat source and ambient temperature the response may vary depending on the installation site floor heating hot environment etc top view frontal detection NOT SENSITIVE detection range approx 50 max 14m tangential detection SENSITIVE max 14m ide view 5m d 2x h Troubleshooting error cause amendment light does not turn on twilight adjustment value too low connected lamp defective check mains power fuses detector triggers without check detection area for potential reason light never turns causes of false triggeri
6. lux memory via remote ctrl AUTO ON OFF 4 to 6 m range 200 horizontal 360 creep zone protection 14 m max frontal 7 m max lateral 5 m creep zone protection 2to4m 86 x 86 x 68 mm SG 3100 IR on frame 70 x 70 x 88 mm SG 3100 IR on wall mount socket IP 55 class Il Induction in long installation wires if several detectors connected in parallel may generate a considerable capacitive current on the switched phase For electric loads using only a small control current such as staircase timer switches this may lead to permanent switching or general malfunctions In order to minimise the capacitive current an RC element may be connected in parallel to the load Alternatively a contactor which is more tolerant to Capacitive currents may be installed before the load We recommend a maximum of four detectors connected in parallel Do not dispose of electrical appliances in your waste bin use Z the collecting point of your municipality or return the old device to your dealer ab CE Zublin
7. ng draught ani off mals heating etc may all provoke faulty switching detector is too sensitive reduce the detec tion range sensitivity by remote control or VR or cover disturbing segments on the lens by adhesive tape check distances to lamps heat reflection or direct light influence connect RC element in parallel to transfor mers relais electric ballast light flashes periodically non compensated fluorescent lamps need detector doesn t reach an RC element or compensation conden proper working condition ser installed triggers or blocks at mains install a Varistor between phase L and voltage peaks neutral N wires light turns off even if motion increase the TIME value to maximum if is detected needed turns the light on during twilight adjustment set too high set to daytime a lower value Respect 1 min start up detector is installed in the shade consider changing the location of detector After mains connection the detector takes approx 1 min to reach a stable working condition Technical data Nominal power Switching power Time adjustment Twilight switch IR remote control Detection area Detection range Rec install height Dimensions IP protection Electronic Control 230V 50Hz 2300W 10A max cos p 1 1150VA 5A max inductive cos 0 5 short impulse approx 1 sec 20 60 sec break approx 10 sec to 20 min 5 to 2000 lux or