Home
Intel(R) Multi-Flex Server Compute Module MFS5000SI User Guide
Contents
1. 128 Intel Compute Module MFS5520VI User Guide it M RE FIR
2. 9 9 0 NEE END Intel Compute Module MFS5520VI User Guide BG Mr 127 ITE BA BE ITE
3. o FE EIN BEE y N 5V
4. PASSWORD Clear 3 2 v Qu vo ego e AA Clear Defau Password J9A3 2 7 j AF003231 Figure 62 Password Clear Jumper Intel Compute Module MFS5520VI User Guide 5 Replace the compute module cover 6 Insert the compute module into the Intel Modular Server System 7 Power on the compute module and then press lt F2 gt to enter the BIOS Setup Utility menu to check if the password is cleared 8 Repeat steps 1 3 9 Move the Password Clear jumper back to its default position covering pins 1 and 2 10 Replace the compute module cover 11 Insert the compute module into the Intel Modular Server System 12 Power on the compute module and then press lt F2 gt to enter the BIOS Setup Utility menu to check if the password is cleared The password is now cleared and you can reset it by going into the BIOS Setup Utility Intel Compute Module MFS5520VI User Guide 91 Clearing the CMOS If you cannot access the BIOS setup screens you must use the CMOS Clear jumper to reset the configurat
5. FRE AV ME LEE A FER SHORE CEA DE ATR VAE RE LEN o Di VAART EE Eo AIRE REEL ft IR Eitt E Intel Compute Module MFS5520VI User Guide DEREN Intel Compute Module MFS5520VI User Guide 131 132 Intel Compute Module MFS5520VI User Guide D Installation Assembly Safety Ins
6. O m O TT sai DIMM F1 L DIMM D2 DIMM F2 DIMM D1 DIMM E1 DIMM E2 AF003100 Figure 34 Removing DIMMs Intel Compute Module MFS5520VI User Guide 8 Reinstall the processor air duct see Figure 35 AF003080 Figure 35 Reinstalling Processor Air Duct 9 Reinstall the top cover For instructions see Installing the Top Cover on page 16 10 Reinstall the server compute module in the chassis For instructions see Installing a Compute Module into the Chassis on page 14 Intel Compute Module MFS5520VI User Guide 41 Installing and Removing Mezzanine Card Installing the Mezzanine Card To install the mezzanine card follow these steps 1 Observe the safety and ESD information at the beginning of this manual and in the appendices 2 Ifthe compute module is installed in a chassis remove it For instructions see Removing a Compute Module from the Chassis on page 13 Remove the top cover For instructions see Removing the Top Cover on page 14 Holding the mezzanine card by its edges remove it from the packaging Remove the protective connector cover from the mezzanine card NR Locate the mezzanine card connectors on the
7. 2 2545 1640 Thailand 1 800 631 0003 Vietnam 632 6368416 IDD via Philippines Domestic 0120 868686 Outside country 81 298 47 0800 Latin America 102 Argentina Contact AT amp T USA at 0 800 222 1288 Once connected dial 800 843 4481 Brazil 001 916 377 0180 Chile Easter Island Contact AT amp T USA at 800 800 311 Once connected dial 800 843 4481 Mainland and Juan Contact AT amp T USA at 800 225 288 Once connected dial 800 843 4481 Intel Compute Module MFS5520VI User Guide Colombia Contact AT amp T USA at 01 800 911 0010 Once connected dial 800 843 4481 Costa Rica Contact AT amp T USA at 0 800 0 114 114 Once connected dial 800 843 4481 Ecuador Andimate Contact AT amp T USA at 1 999 119 Once connected dial 800 843 4481 Pacifictel Contact AT amp T USA at 1 800 225 528 Once connected dial 800 843 4481 Guatemala Contact AT amp T USA at 99 99 190 Once connected dial 800 843 4481 Mexico Contact AT amp T USA at 001 800 462 628 4240 Once connected dial 800 843 4481 Miami 1 800 621 8423 Panama Contact AT amp T USA at 00 800 001 0109 Once connected dial 800 843 4481 Paraguay 001 916 377 0114 Peru 001 916 377 0114 Uruguay 001 916 377 0114 Venezuela Contact AT amp T USA at 0 800 2255 288 Once connected dial 800 843 4481 Intel Compute Module MFS5520VI User Guide 103 104 Intel Compute M
8. Das System ist f r den Betrieb innerhalb normaler B roumgebungen geeignet W hlen Sie einen Standort der folgenden Kriterien entspricht Sauber trocken und frei von Partikeln in der Luft au er dem normalen Raumstaub Gut bel ftet nicht in der N he von W rmequellen und keiner direkten Sonnenbestrahlung ausgesetzt Nicht in der N he von Vibrations oder Erschiitterungsquellen Abgeschirmt von starken elektromagnetischen Feldern die durch elektrische Ger te erzeugt werden In gewittergef hrdeten Gebieten sollten Sie das System an einen berspannungsschutz anschlie en und bei einem Gewitter die Telekommunikationskabel zum Modem abziehen Eine ordnungsgem geerdete Wandsteckdose mu vorhanden sein Ausreichender Freiraum f r den Zugang zu den Netzkabeln da diese die Hauptvorrichtung zum Trennen des Produkts von der Stromversorgung sind Handhabung von Ger ten Beachten Sie zur Vermeidung von Verletzungen oder Besch digungen an den Ger ten die folgenden Hinweise 114 Halten Sie beim Transportieren und Anheben von Ger ten die rtlichen Gesundheits und Sicherheitsvorschriften ein Verwenden Sie mechanische oder andere geeignete Hilfsmittel zum Transportieren oder Anheben von Ger ten Entfernen Sie alle Komponenten die sich leicht abnehmen lassen um das Gewicht zu reduzieren und die Handhabung zu erleichtern Intel Compute Module MFS5520VI User Guide Warnungen zu Netzspannung und Elektrizit t
9. Vorsicht Durch Bet tigen der mit dem Standby Symbol gekennzeichneten Netztaste wird das System NICHT vollst ndig vom Netz getrennt Es sind weiterhin 5 V aktiv solange das System eingesteckt ist Um das System vollst ndig vom Strom zu trennen mu das Netzkabel aus der Steckdose abgezogen werden Das System verf gt m glicherweise ber mehrere Netzkabel Vergewissern Sie sich in diesem Fall da alle Netzkabel abgezogen sind Wenn Sie Komponenten ein oder ausbauen m chten die nicht hot plug f hig sind stellen Sie sicher da zuvor alle Netzkabel abgezogen sind Nehmen Sie keine nderungen am Netzkabel vor und verwenden Sie kein Kabel das nicht genau dem geforderten Typ entspricht Jedes Netzteil im System mu ber ein eigenes Netzkabel angeschlossen werden Einige Netzteile von Intel Servern verwenden Nullleitersicherungen Vorsicht ist geboten im Umgang mit Netzteilen welche Nullleitersicherungen verwenden um das Risiko eines elektrischen Schlages zu vermeiden Das Netzteil in diesem Produkt enth lt keine Teile die vom Benutzer gewartet werden k nnen ffnen Sie das Netzteil nicht Im Netzteil bestehen gef hrliche Spannungen Str me und Energiequellen Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Wenn Sie ein hot plug f higes Netzteil austauschen ziehen Sie dessen Netzkabel ab bevor Sie es aus dem Server ausbauen Zur Vermeidung von Stromschl gen schalten Sie den Server aus und trenne
10. Compute Module MFS5520VI User Guide NY AF002835 Figure 20 Lifting Processor Socket Handle 10 Push the rear tab with your finger tip to bring the front end of the load plate open slightly see letter A in Figure 21 11 Open the load plate see letter B in Figure 21 AF003096 Figure 21 Opening the Load Plate 12 Remove the processor Note Do not touch the socket pins they are very sensitive and easily damaged Intel Compute Module MFS5520VI User Guide 27 28 AF003097 Figure 22 Removing the Processor Intel Compute Module MFS5520VI User Guide Installing the Replacement Processor 13 If present remove the protective shipping cover from the replacement processor AF002838 Figure 23 Removing Protective Shipping Cover 14 Orient the replacement processor with the processor socket so that the processor cutouts match the socket notches Install the replacement processor see Figure 24 Caution The underside of the processor has components that may damage the socket pins if installed improperly Processor must align correctly with socket opening before installation DO NOT DROP processor into socket AF002839 Figure 24 Orienting and Installing Processor 15 Close the processor load plate see letter A in Figure 25 16 Close the socket lever completely and ensure that the load plate tab engages under the socket lever when fully closed see letter B in Fig
11. Intel Compute Module MFS5520VI User Guide Additional Information and Software If you need more information about this product or information about the modular server systems that can be used with the compute module use the following resources For this information or software Use this Document or Software If you just received this product and you need to install components in your compute module IntePCompute Module MFS5520VI Quick Start User s Guide Available in the product box or for download at http www intel com support motherboards server mfs5520vi For in depth technical information about the compute module including chipset information and mechanical drawings Inte Compute Module MFS5520VI Technical Product Specification Available at http www intel com support motherboards server mfs5520vi If you just received this product and you need to assemble your modular server system and install components Intel Modular Server System MFSYS25 MFSYS35 Quick Start User s Guide Available in the product box or for download at http www intel com support motherboards server mfsys25 Intel Modular Server System MFSYS25 MFSYS35 User s Guide Available at http www intel com support motherboards server mfsys25 For in depth technical information about the modular server system including subsystem overviews and mechanical drawings Intel Modular Server System MFSYS25 MFSY
12. Le nombre de c bles d alimentation CA fournis correspond au nombre de blocs d alimentation du produit Notez que le commutateur CC de mise sous tension hors tension du module n teint pas l alimentation CA du syst me Pour mettre le syst me hors tension vous devez d brancher chaque cable d alimentation de sa prise C est le c ble d alimentation qui est consid r comme le moyen de se d connecter du CA La prise laquelle le syst me est branch doit se situer proximit de l quipement et tre facilement accessible CONSIGNES DE S CURIT Lorsque vous ouvrez le bo tier pour acc der l int rieur du syst me suivez les consignes suivantes 1 Mettez hors tension tous les p riph riques connect s au syst me 2 Mettez chaque module hors tension en mettant l interrupteur en position OFF bouton poussoir 3 D branchez tous les cordons d alimentation c a du syst me et des prises murales 4 Identifiez et d branchez tous les c bles reli s aux connecteurs d E S ou aux acc s derri re le syst me 5 Pour pr venir les d charges lectrostatiques lorsque vous touchez aux composants portez une bande antistatique pour poignet et reliez la la masse du syst me toute surface m tallique non peinte du bo tier 6 Ne faites pas fonctionner le syst me tandis que le bo tier est ouvert Une fois TOUTES les tapes pr c dentes accomplies vous pouvez retirer les panneaux du syst me Pro
13. boot is disabled when you power on the compute module When the BIOS Setup Utility is entered the Main screen is displayed by default If serious errors have occurred the Error Manager screen is displayed instead of the Main screen If You Cannot Access Setup If you cannot access the BIOS Setup you might need to clear the CMOS memory For instructions on clearing the CMOS see Section Clearing the CMOS on page 92 General Layout and Navigation The BIOS Setup page layout is sectioned into functional areas Each occupies a specific area of the screen and has a dedicated functionality The following table lists and describes each functional area Intel Compute Module MFS5520VI User Guide 53 54 Quiet Boot Aptio Setup Utility Copyright C 2009 American Megatrends Inc Disabled Functional Area Description Menu Selection Bar The Menu selection bar is located at the top of the BIOS Setup Utility screen It displays the major menu selections available to the user By using the left and right arrow keys the user can select the listed menus Some menus are hidden and become available by scrolling to the left or right of the current selection Setup Item List The Setup Item List is a set of controllable and informational items Each item in the list occupies the left column of the screen A Setup Item may also open a new window with more options for that functionality on the board I
14. 2 or all cores of the installed processor Processing 1 packages 2 Intel Compute Module MFS5520VI User Guide Table 6 Advanced Processor Configuration Details Setup Item Options Description Execute Enabled Execute Disable Bit can help prevent certain classes Disable Bit i of malicious buffer overflow attacks Disabled Contact your OS vendor regarding OS support of this feature Intel Enabled Intel Virtualization Technology allows a platform to Virtualization Disabled run multiple operating systems and applications in Technology sane independent partitions Intel Enabled Enable Disable Intel Virtualization Technology for Virtualization Disabled Directed I O Technology for Sable Directed I O Hardware Enabled Hardware Prefetcher is a speculative prefetch unit Prefetcher within the processor s Disabled NOTE Modifying this setting may affect system performance Adjacent Cache Enabled Enabled Cache lines are fetched in pairs even Line Prefetch line odd line Disabled Disabled Only the current cache line required is fetched NOTE Modifying this setting may affect system performance Direct Cache Enabled Allows processors to increase the I O performance Access DCA Disabled by placing data from I O devices directly into the Bade processor cache Memory Configuration The Advanced Memory Configuration screen provides information about the installed memory modules
15. Il pulsante non interrompe l alimentazione in c a del modulo Per interromperla necessario scollegare tutti i cavi di alimentazione in c a dalle prese a muro o dall alimentazione di corrente Il cavo considerato il dispositivo d interruzione dell alimentazione principale in c a La presa alla quale si collega il sistema deve essere installata vicino all unit e deve essere facilmente accessibile PASSI DI SICUREZZA Qualora si rimuovano le coperture del telaio per accedere all interno del sistema seguire i seguenti passi 1 Spegnere tutti i dispositivi periferici collegati al sistema 2 Spegnere ciascun modulo usando il pulsante di alimentazione 3 Togliere tutte le spine dei cavi del sistema dalle prese elettriche 4 Identificare e sconnettere tutti i cavi attaccati ai collegamenti I O od alle prese installate sul retro del sistema 5 Qualora si tocchino i componenti proteggersi dallo scarico elettrostatico SES portando un cinghia anti statica da polso che attaccata alla presa a terra del telaio del sistema qualsiasi superficie non dipinta 6 Non far operare il sistema quando il telaio senza le coperture Dopo aver seguito i sei passi di SICUREZZA sopracitati togliere le coperture del telaio del sistema come seque 1 Aprire e rimuovere il lucchetto dal retro del sistema qualora ve ne fosse uno installato 2 Togliere e mettere in un posto sicuro tutte le viti delle coperture 3 Tog
16. Intel Compute Module MFS5520VI User Guide 18 Removing the Heatsink Caution Improper removal can damage the heatsink Pay close attention to the steps and perform each step exactly as indicated to avoid damage Note This procedure assumes that you are removing the heatsink for the first time Note If you are installing only a single processor on your server board do not remove the heatsink and spacer over the second processor 5 Loosen the four captive screws on the heatsink corners in a diagonal manner according to the numbers shown in Figure 9 as follows a Starting with the screw at location 1 loosen it by giving it two rotations in the anticlockwise direction see letter A in Figure 9 and stop IMPORTANT Do not fully loosen b Proceed to the screw at location 2 and loosen it by giving it two rotations and stop c Loosen screws at locations 3 and 4 by giving each screw two rotations and then stop d Repeat steps Sa through Sc by giving each screw two rotations each time until all screws are loosened Lift the heatsink from the board see letter B in Figure 9 Remove and discard the spacer see letter C in Figure 9 Note The system is shipped with a spacer installed between the heatsink and the processor socket to protect the socket protective cover This spacer will need to be removed and discarded before installing the processor AF003161 Figure 9 Removing the Heatsink Intel Co
17. Isolated from strong electromagnetic fields produced by electrical devices e Inregions that are susceptible to electrical storms we recommend you plug your compute module into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm e Provided with a properly grounded wall outlet e Provided with sufficient space to access the power supply cord s because they serve as the product s main power disconnect Equipment Handling Practices Reduce the risk of personal injury or equipment damage e Conform to local occupational health and safety requirements when moving and lifting equipment e Use mechanical assistance or other suitable assistance when moving and lifting equipment e To reduce the weight for easier handling remove any easily detachable components Power and Electrical Warnings Caution The power button indicated by the stand by power marking DOES NOT completely turn off the compute module AC power 5V standby power is active whenever the compute module is plugged in To remove power from compute module you must unplug the AC power cord from the wall outlet Your compute module may use more than one AC power 110 Intel Compute Module MFS5520VI User Guide cord Make sure all AC power cords are unplugged Make sure the AC power cord s is are unplugged before you open the chassis or add or remove any non hot plug components Do not attempt to modify or use an AC power
18. Metallstellen bei der Handhabung der Komponenten zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein Zur ordnungsgem en K hlung und L ftung mu die Geh useabdeckung immer wieder vor dem Einschalten installiert werden Ein Betrieb des Systems ohne angebrachte Abdeckung kann Ihrem System oder Teile darin besch digen Um die Abdeckung wieder anzubringen 1 Vergewissern Sie sich da Sie keine Werkzeuge oder Teile im Innern des Systems zur ckgelassen haben 2 berpr fen Sie alle Kabel Zusatzkarten und andere Komponenten auf ordnungsgem en Sitz und Installation 3 Bringen Sie die Abdeckungen wieder am Geh use an indem Sie die zuvor gel sten Schrauben wieder anbringen Ziehen Sie diese gut an 4 Bringen Sie die Verschlu einrichtung Padlock wieder an und schlie en Sie diese um ein unerlaubtes Offnen des Systems zu verhindern 5 Schlie en Sie alle externen Kabel und den AC Stromanschlu stecker Ihres Systems wieder an Der Mikroprozessor und der K hler sind m glicherweise erhitzt wenn das System in Betrieb ist Au erdem k nnen einige Platinen und Geh useteile scharfe Spitzen und Kanten aufweisen Arbeiten an Platinen und Geh use sollten vorsichtig ausgef hrt werden Sie sollten Schutzhandschuhe tragen Bei falschem Einsetzen einer neuen Batterie besteht Explosionsgefahr Die Batterie darf nur durch denselben oder einen entsprechenden vom Herstel
19. Notes The System Acoustic and Performance Configuration screen allows the user to configure the DIMM thermal management option for the Intel Compute Module MFS5520VI Specifically the System Acoustics and Performance Configuration screen allows the user to set the DIMM throttling mode to Auto default Static Closed Loop Thermal Throttling CLTT or Static Open Loop Thermal Throttling OLTT By default this field is set to Auto When set to Auto the BIOS will configure the system for Static Closed Loop Thermal Throttling CLTT as long as the installed DIMMs have Module Thermal Sensors With the Throttling mode set to CLTT the system is able to accurately control memory temperatures which is necessary to manage system performance within thermal parameters To set the throttling mode select one of the following configuration options e Auto Auto Throttling mode e CLTT Closed Loop Thermal Throttling Mode e OLTT Open Loop Thermal Throttling Mode The OLTT option is shown for informational purposes only If the user selects OLTT the BIOS overrides that selection if the system can support CLTT OLTT is configured only when unbuffered DIMMs UDIMMs UDIMMSs without Thermal Sensors are installed To access this screen from the Main screen press the right arrow key until the Advanced menu is selected then press the down or up arrow key to highlight System Acoustics and Performance Configuration and press lt Enter gt Intel Compute
20. Removing Processor Ar Duct nn 39 RemevingDIMMS esiliati 40 Reinstalling Processor Air Duct Lui 41 Removing Screws from Server Board n 43 Installing Standoffs for Mezzanine Card i 44 Figure 38 Installing and Securing the Mezzanine Card conan cc nnnnnaccnnns 45 Figure 39 Removing Screws from Mezzanine Card 46 Figure 40 Removing Mezzanine Cargd e 47 Figure 41 Removing StandoffS tinta este 48 Figure 42 CMOS Battery Location pp 50 Intel Compute Module MFS5520VI User Guide xi Figure 43 Figure 44 Figure 45 Figure 46 Figure 47 Figure 48 Figure 49 Figure 50 Figure 51 Figure 52 Figure 53 Figure 54 Figure 55 Figure 56 Figure 57 Figure 58 Figure 59 Figure 60 Figure 61 Figure 62 Figure 63 xii P E OO O N ERE A 54 Ma ES el EE EE Ce Red 58 Advanced Screen Vee 60 Advanced Processor Configuration Screen pp 61 Advanced Memory Configuration Screen pp 64 Memory RAS and Performance Configuration Screen 66 Advanced Mass Storage Controller Configuration Screen 67 Advanced Serial Port Configuration Screen 68 Advanced USB Configuration Screen 69 Advanced PCI Configuration Screen cane nc nc nnnnancnnns 71 Advanced System Acoustics and Performance Configuration Screen 73 Security Screen pp 74 Server Management Screen pp 76 Server Management Console Redirection Enabled Screen 79 Ser
21. TE OE MSDN BITS KUBER KINE RRC N RT RER FIRE RER RER Tam AAA 1A A Beas RETREAT BAF RSH RBH ARR eet Intel Compute Module MFS5520VI User Guide 129 ESD E ken ED een ESD E eat Re BIE REESE DEEP EP ESD
22. This screen also provides a link to configure memory RAS Reliability Availability and Serviceability and view memory performance information and settings To access this screen from the Main screen press the right arrow key until the Advanced menu option is selected then select Memory Configuration from the Advanced menu Intel Compute Module MFS5520VI User Guide 63 64 Aptio Setup Utility Copyright C 2009 American Megatrends Inc Memory RAS and Performance Configuration Figure 47 Advanced Memory Configuration Screen Intel Compute Module MFS5520VI User Guide The following table describes the features of the Advanced Memory Configuration screen Table 7 Advanced Memory Configuration Screen Details Setup Item Options Description Total Memory Information only The amount of memory available in the system in the form of installed DIMMs in units of MB or GB Effective Information only The amount of memory available to Memory the OS in MB or GB The Effective Memory is the difference between the Total Physical Memory and the sum of all memory reserved for internal usage RAS redundancy and SMRAM This difference includes the sum of all DIMMs that failed Memory BIST during POST or were disabled by the BIOS during the memory discovery phase in order to optimize memory configuration Current Information only Displays one of the following Confi ti ere Independent Mode System me
23. antes de instalar o mantener el producto de servidor de Intel En el caso de que haya diferencias entre la informaci n para un producto en particular contenida en este documento y la informaci n proporcionada con dicho producto o en el sitio Web la documentaci n del producto es la que prevalece S lo personal t cnico calificado debe montar y prestar los servicios para el servidor Debe ce irse a las directrices de esta gu a y a las instrucciones de montaje de los manuales del servidor para asegurar y mantener el cumplimiento con las certificaciones y homologaciones existentes de los productos Utilice s lo los componentes descritos y homologados que se especifican en esta gu a El uso de otros productos o componentes anular la homologaci n UL y otras certificaciones oficiales del producto pudiendo dejar de ser compatible con las normativas locales de los pa ses en los que se comercializa Advertencias y precauciones sobre seguridad 122 Para reducir la posibilidad de que se produzcan lesiones personales o da os en la propiedad antes de empezar a instalar el producto lea observe y cumpla toda la informaci n e instrucciones de seguridad siguientes Puede que se utilicen los siguientes s mbolos de seguridad en la documentaci n y es posible que aparezcan en el producto o en su embalaje Intel Compute Module MFS5520VI User Guide PRECAUCI N Indica la existencia de un riesgo que podria causar lesiones personales o
24. cord if it is not the exact type required A separate AC cord is required for each compute module power supply Some power supplies in Intel servers use Neutral Pole Fusing To avoid risk of shock use caution when working with power supplies that use Neutral Pole Fusing The power supply in this product contains no user serviceable parts Do not open the power supply Hazardous voltage current and energy levels are present inside the power supply Return to manufacturer for servicing When replacing a hot plug power supply unplug the power cord to the power supply being replaced before removing it from the server To avoid risk of electric shock turn off the server and disconnect the power cord telecommunications systems networks and modems attached to the server before opening it Access Warnings Caution To avoid personal injury or property damage the following safety instructions apply whenever accessing the inside of the product Turn off all peripheral devices connected to this product Turn off the compute module by pressing the power button off e Disconnect the AC power by unplugging all AC power cords from the chassis or wall outlet Disconnect all cables and telecommunication lines that are connected to the compute module Retain all screws or other fasteners when removing access cover s Upon completion of accessing inside the product refasten access cover with original screws or fasteners Do not acc
25. dafios en la propiedad leves si no se tiene en cuenta la PRECAUCION ADVERTENCIA Indica la existencia de un riesgo que podria causar lesiones personales graves si no se tiene en cuenta la ADVERTENCIA Indica un riesgo potencial si no se tiene en cuenta la informaci n indicada Indica riesgo de descargas el ctricas que podrian causar lesiones graves o la muerte si no se siguen las instrucciones de seguridad Indica componentes o superficies calientes Indica que no se deben tocar las aspas de los ventiladores ya que de lo contrario se podrian producir lesiones ESP PP Sa Indica que es necesario desenchufar los cables de alimentaci n de CA para mm desconectar la alimentaci n de CA Es Recicle por favor la bateria Aplicaciones y usos previstos Este producto ha sido evaluado como equipo de tecnologia inform tica ITE que puede instalarse en oficinas escuelas salas de equipos inform ticos o lugares de mbito comercial similares Es posible que sea necesario Ilevar a cabo una evaluaci n adicional para comprobar si este producto es apropiado para otras categorias de productos y entornos adem s de las aplicaciones inform ticas por ejemplo soluciones m dicas industriales residenciales sistemas de alarma y equipos de pruebas Selecci n de la ubicaci n El sistema se ha dise ado para funcionar en un entorno normal de oficinas Seleccione una ubicaci n que est Limpia seca y lib
26. following figure Processor Socket 1 Processor Socket 2 Channel A Channel B Channel C Channel D Channel E Channel F Al A2 B1 B2 C1 C2 DI D2 E1 E2 F1 F2 Figure 28 DIMM Nomenclature The following general rules must be observed when selecting and configuring memory to obtain the best performance from the compute module Mixing RDIMMs and UDIMMs is not supported DIMMs are organized into physical slots on DDR3 memory channels that belong to processor sockets The memory channels from processor socket 1 are identified as Channel A B and C The memory channels from processor socket 2 are identified as Channel D E and F The DIMM slot identifiers on the compute module Quick Reference Label provide information about the channel and therefore the processor to which they belong For example DIMM Al is the first DIMM slot on Channel A on processor 1 DIMM_D1 is the first DIMM socket on Channel D on processor 2 When CPU Socket I is empty any DIMM memory in Channel A through Channel C is unavailable When CPU Socket 2 is empty any DIMM memory in Channel D through Channel F is unavailable If both processor sockets are populated but Channel A through Channel C is empty the platform can still function with remote memory in Channel D through Channel F However platform performance suffers latency due to remote memory The memory operational mode is configurable at the channel level Two
27. front of the compute module Removing or Installing the Top Cover Removing the Top Cover To remove the top cover follow these steps 1 Observe the safety and ESD information at the beginning of this manual and in the appendices 2 Ifthe compute module is installed in a chassis remove it For instructions see Removing a Compute Module from the Chassis on page 13 3 Carefully lay the compute module down on a flat non conductive surface with the cover side up 14 Intel Compute Module MFS5520VI User Guide 4 Press the top cover release button see letter A in Figure 6 and slide the top cover back away from the compute module bezel see letter B in Figure 6 5 Lift the top cover up and off the compute module see letter C in Figure 6 Caution Always install the top cover before installing the compute module into a chassis AF003088 Figure 6 Removing Top Cover Intel Compute Module MFS5520VI User Guide 15 Installing the Top Cover To install the top cover follow these steps 1 Observe the safety and ESD information at the beginning of this manual and in the appendices 2 Place the top cover on the compute module so that it engages the cover guide notches see letter A in Figure 7 Note Before closing the top cover check that all components are installed and seated correctly and that no loose tools or parts are inside the compute module 3 Slide the top cover for
28. hrten Sicherheitshinweise und informationen sorgf ltig lesen und befolgen In dem vorliegenden Handbuch sowie auf dem Produkt und auf der Verpackung werden folgende Sicherheitssymbole verwendet Weist auf eine Gefahrenquelle hin die bei Nichtbeachtung des VORSICHT VORSICHTSHINWEISES zu leichteren Verletzungen bzw Sachbesch digungen f hren kann WARNUNG Weist auf eine Gefahrenquelle hin die bei Nichtbeachtung der WARNUNG zu ernsten Verletzungen f hren kann Weist auf potentielle Gefahr bei Nichtbeachtung der angezeigten Informationen hin Weist auf die Gefahr eines Stromschlags hin der bei Nichtbeachtung der Sicherheitshinweise zu schweren oder t dlichen Verletzungen f hren kann Weist auf Verbrennungsgefahr an hei en Bauteilen bzw Oberfl chen hin Weist darauf hin da das Anfassen des Gebl ses zu Verletzungen f hren kann EOP gt gt Sa Bedeutet alle Netzkabel abzuziehen und das Ger t von der Netzspannung zu trennen Intel Compute Module MFS5520VI User Guide 113 6 Bereiten Sie bitte Batterie auf Zielbenutzer der Anwendung Dieses Produkt wurde in seiner Eigenschaft als IT Ger t getestet das in B ros Schulen Computerr umen und hnlichen ffentlichen R umlichkeiten installiert werden kann Die Eignung dieses Produkts f r andere Einsatzbereiche als IT z B Medizin Industrie Alarmsysteme oder Pr fger te kann u U weitere Tests erfordern Standortauswahl
29. in a chassis remove it For instructions see Removing a Compute Module from the Chassis on page 13 3 Remove the top cover For instructions see Removing the Top Cover on page 14 Intel Compute Module MFS5520VI User Guide 49 50 4 Locate the CMOS battery see letter A in Figure 41 10 O m O HL Ht vo uy 2 7 AF003101 Figure 42 CMOS Battery Location Insert the tip of a small flat head screwdriver or equivalent under the tab in the plastic retainer Gently push down on the screwdriver to lift the battery Remove the battery from its socket Dispose of the battery according to local ordinance Remove the new lithium battery from its package and being careful to observe the correct polarity insert it in the battery socket Reinstall the top cover For instructions see Installing the Top Cover on page 16 Reinstall the server compute module in the chassis For instructions see Installing a Compute Module into the
30. in the associated pick list without displaying the full list F6 Change Value The plus key or the F6 function key is used to change the value of the current menu item to the next value This key scrolls through the values in the associated pick list without displaying the full list lt Enter gt Execute Command The Enter key is used to activate submenus when the selected feature is a submenu or to display a pick list if a selected feature has a value field or to select a sub field for multi valued features like time and date If a pick list is displayed the Enter key will undo the pick list and allow another selection in the parent menu lt Esc gt Exit The ESC key provides a mechanism for backing out of any field This key will undo the pressing of the Enter key When the ESC key is pressed while editing any field or selecting features of a menu the parent menu is re entered When the ESC key is pressed in any submenu the parent menu is re entered When the ESC key is pressed in any major menu the exit confirmation window is displayed and the user is asked whether changes can be discarded lt F9 gt Setup Optimized Defaults Pressing F9 causes the following to display Load Optimized Defaults Load Optimized Defaults If Yes is selected and the Enter key is pressed all Setup fields are set to their default values If No is selected and the Enter key is pressed or if the ESC key
31. inaroeeiiiE a Ea EE ai i E R aE aE 102 JAPAN a EAR N RER T EEAS il 102 Latin AMENCA ee 102 B Product Regulatory Requirements rrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 105 Regulatory and Certification Information i 105 viii Intel Compute Module MFS5520VI User Guide Product Regulatory Compliance and Safety Markings pp 105 Product Environmental Ecology Requirement pp 105 Product Environmental Ecology Markings ee 105 C Safety Information aia avala 107 Efiglish ea 107 Server Safety Information iii 107 Safety Warnings and Cautions iii 107 Intended Application Uses sise 108 Site Selection ss en a 108 Equipment Handling Practices ss 108 Power and Electrical Warnings i ss 108 ACCESS Warnings 0 a i ee 109 Electrostatic Discharge ESD siirretiin iia Ea a aian 110 Other Hazards dmd ei 110 PUR 111 Sicherheitshinweise f r den Server sisi 111 Sicherheitshinweise und VorsichtsmaBnahmen 240unnssnnnnnnnnnnnnnnnnnenannennnnnn mann 111 Zielbenutzer der Anwendung sms a ee 112 Standortauswahl sen a oe rn Perl erinnere 112 Handhabung von Ger ten iii 112 Warnungen zu Netzspannung und Elektrizit t ss 113 Warnhinweise f r den Systemzugang ii 113 Elektrostatische Entladungen ESD conan nnnnnn cc cnn n anar cnn rca ranma 114 Andere Gefahren me a iar aaa aiaa aai iaaa adian 115 FAN EA 116 Consignes de s curit sur le serveur iii 116 S curit avertiss
32. is pressed the user is returned to where they were before F9 was pressed without affecting any existing field values Intel Compute Module MFS5520VI User Guide 55 56 Table 4 Keyboard Commands Press Description lt F10 gt Save and Exit Pressing F10 causes the following message to display Save amp reset Save configuration and reset If Yes is selected and the Enter key is pressed all changes are saved and Setup is exited If No is selected and the Enter key is pressed or the ESC key is pressed the user is returned to where they were before F10 was pressed without affecting any existing values Intel Compute Module MFS5520VI User Guide Setup Menus Each BIOS Setup menu page contains a number of features Except for those features provided only to display automatically configured information each feature is associated with a value field that contains user selectable parameters A user can change these parameters if they have adequate security rights If a value cannot be changed for any reason the feature s value field is inaccessible The following sections describe the look and behavior for the BIOS Setup Utility In these sections tables describe the contents of each screen These tables follow the below mentioned guidelines e The text and values in the Setup Item and Options columns are displayed on the BIOS Setup screens e In the Options column the default values ar
33. on page 97 Specific Problems and Corrective Actions This section provides possible solutions for the following problems Power LED does not light No video display Characters on the screen appear distorted or incorrect No available storage Network problems Try the solutions in the order given If you cannot correct the problem contact your service representative or authorized dealer for additional help 96 Intel Compute Module MFS5520VI User Guide Power LED Does Not Light Check the following Did you press the power on button e Is the compute module operating normally If so the power LED might be defective e Is the chassis power LED lit If not refer to the troubleshooting section of the Intel Modular Server System MFSYS25 MFSYS35 User Guide for additional guidance e Is the compute module fully seated in the chassis No Video Display Check the following e Is the power LED lit If not refer to Power LED Does Not Light on page 97 Verify that the video monitor is turned on and functioning properly Verify that the brightness and contrast controls on the video monitor are properly adjusted Does this video monitor work correctly if plugged into a different compute module Verify that the installed processor s are validated for use in the compute module e If only a single processor is installed verify that it is installed in the first processor socket e Remove and re seat the proces
34. other than normal room dust i No Well ventilated and away from sources of heat including direct sunlight Away from sources of vibration or physical shock Isolated from strong electromagnetic fields produced by electrical devices In regions that are susceptible to electrical storms we recommend you plug your system into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm e Provided with a properly grounded wall outlet e Provided with sufficient space to access the power supply cord s because they serve as the product s main power disconnect 134 Intel Compute Module MFS5520VI User Guide Deutsch Benutzer k nnen am Netzger t dieses Produkts keine Reparaturen vornehmen Das Produkt enth lt m glicherweise mehrere Netzger te Wartungsarbeiten m ssen von qualifizierten Technikern ausgef hrt werden Versuchen Sie nicht das mitgelieferte Netzkabel zu ndern oder zu verwenden wenn es sich nicht genau um den erforderlichen Typ handelt Ein Produkt mit mehreren Netzger ten hat f r jedes Netzger t ein eigenes Netzkabel Der Wechselstrom des Rechenmoduls wird durch den Ein Aus Schalter f r Gleichstrom nicht ausgeschaltet Ziehen Sie alle Wechselstrom Netzkabel aus der Steckdose bzw dem Netzger t um den Stromanschluss des Systems zu unterbrechen Die Stromkabel sind das Unterbrechungsger t zur Hauptstromquelle Die Steckdose in die da
35. 0 Chipset I O Hub CPU2 DIMM Slots Mezzanine Card Connector 1 CPU 1 with Heatsink Mezzanine Card Connector 2 CPU 2 Socket Power Fault LEDs Power Switch Activity and ID LEDs Video Connector USB Ports 2 and 3 USB Ports 0 and 1 CMOS Battery Midplane Power Connector Midplane Signal Connector T Q m O O O gt Olu o Zl r a O Midplane Guide Pin Receptacle CPU 1 DIMM Slots Figure 3 Component and Connector Locations 4 Intel Compute Module MFS5520VI User Guide Configuration Jumpers BIOS Recover Boot from Emergency BIOS Image Default J9B9 PASSWORD Clear 3 2 V o KERI Lu Clear Defaul Password CMOS Clear dt Clear Default CMOS J9A4 BMC Force Update 3 2 7 o O dl Enabled Defau Disab J9A5 AF003078 Figure 4 Configuration Jumper Locations Intel Compute Module MFS5520VI User Guide Table 2 Configuration Jumper Descrip
36. 1 DIMM E2 AF003099 Figure 31 Installing DIMMs 13 Reinstall the processor air duct see Figure 32 Intel Compute Module MFS5520VI User Guide 37 AF003080 Figure 32 Reinstalling Processor Air Duct 14 Reinstall the top cover For instructions see Installing the Top Cover on page 16 15 Reinstall the server compute module in the chassis For instructions see Installing a Compute Module into the Chassis on page 14 Removing DIMMs To remove DIMMs follow these steps 1 Observe the safety and ESD information at the beginning of this manual and in the appendices 2 If the compute module is installed in a chassis remove it For instructions see Removing a Compute Module from the Chassis on page 13 3 Remove the top cover For instructions see Removing the Top Cover on page 14 38 Intel Compute Module MFS5520VI User Guide 4 Remove the processor air duct see Figure 33 AF003080 Figure 33 Removing Processor Air Duct 5 Locate the DIMM socket 6 Gently open the retaining clips at each end of the socket see letter A in Figure 34 This slightly lifts the DIMM from its socket 7 Holding the DIMM by the edges remove it from the socket see letter B in Figure 34 Intel Compute Module MFS5520VI User Guide 39 40 Important Store the removed DIMM in an anti static package DIMM B2 DIMM B1 DIMM A1 DIMM C2 DIMM A2 m DIMM C1
37. 2 Activity LEDs F Drive Activity LED G IDLED H Power Button I Fault LED J Power LED Figure 5 Front Panel Connectors and Indicators Front Panel Indicators The Intel Compute Module MFS5520VI includes a number of diagnostic LEDs on the front of the compute module to aid in troubleshooting The following table lists these LEDs along with a usage description of each LED Table 3 Diagnostic LED Information LED Name Function Color Indicator Power LED Identifies power state Green Off Power is off of compute module On Power on Slow Blink Power is in standby or sleeping mode Fault LED Identifies fault warning Amber Off No Fault On Critical error or non recoverable Slow blink Non critical Fast blink Locate when device does not have an ID LED Double blink Degraded state Intel Compute Module MFS5520VI User Guide Table 3 Diagnostic LED Information LED Name Function Color Indicator ID LED Provides an aid in Blue Use the Intel Modular Server Control identifying a compute software to activate or inactivate the LED module from the front panel Drive activity Indicates drive activity Green Off No drive activity LED Blink Drive activity NIC1 2 Indicates network Green Blink Outbound activity LEDs activity and link 1 0 1 1 0 2 Indicates network Green Off No link Activity LED ivi link of BEDS o On Link established mezzanine car
38. 20 minutes Watchdog Timer is disabled Plug amp Play Enabled If enabled BMC will be detectable by OSs which BMC Detection Disabled support plug and play loading of an IPMI driver Do fable not enable if your OS does not support this driver Intel Compute Module MFS5520VI User Guide 77 Table 11 Server Management Screen Details Setup Item Options Description ACPI 1 0 Enabled Enabled Publish ACPI 1 0 version of FADT in Root Support Disabled System Description Table This may be required for compatibility with OS versions that only support ACPI 1 0 NOTE Set to Enabled for Microsoft Windows Server 2000 support Console lt Enter gt Select Console Redirection to view configure console Redirection redirection information and settings This option takes the user to the Console Redirection screen System lt Enter gt View system information Inf i ne This option takes the user to the System Information screen Console Redirection Console redirection enables a serial port to be used for server management tasks The Console Redirection screen enables the user to either disable console redirection or enable console redirection through the Network Serial Console If Console Redirection is set to Network Serial Console the console redirection configuration options Flow Control Baud Rate Terminal Type and Legacy OS Redirection are displayed on the Console Redirection Setup screen Enabling console re
39. Always handle electronic devices carefully They can be extremely sensitive to ESD Do not touch the connector contacts Installing or removing jumpers A jumper is a small plastic encased conductor that slips over two jumper pins Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers If your jumpers do not have such a tab take care when using needle nosed pliers to remove or install a jumper grip the narrow sides of the jumper with the pliers never the wide sides Gripping the wide sides can damage the contacts inside the jumper causing intermittent problems with the function controlled by that jumper Take care to grip with but not squeeze the pliers or other tool you use to remove a jumper or you may bend or break the pins on the board Reinstalling enclosure cover To protect internal components and for proper cooling and airflow the compute module should not be inserted into the chassis with the cover removed operating it without the enclosure cover in place can damage compute module parts Intel Compute Module MFS5520VI User Guide Contents PRES iii About this Manual sg oe een iii Manual Organization iii Safety Information ara i V Important Safety Instructions ae V Wichtige Sicherheitshinweise nenn V Consignes de SEGUI scalare V Instrucciones de seguridad importantes iii V AAA EE ta tec ccc gece cana EE vi Compute Module Feature
40. Chassis on page 14 Intel Compute Module MFS5520VI User Guide 11 Run the BIOS setup to restore the configuration settings to the RTC Intel Compute Module MFS5520VI User Guide 51 52 Intel Compute Module MFS5520VI User Guide 3 BIOS Setup Utility This section describes the text based BIOS Setup Utility The BIOS Setup Utility is used to view and modify configuration settings for the Intel Compute Module MFS5520VI s built in devices boot manager and error manager You can run the BIOS Setup Utility with or without an operating system present Starting BIOS Setup Utility To enter the BIOS Setup Utility complete the following steps 1 Before you begin either a Start a Remote KVM and CD session with the target compute module through the Intel Modular Server Control UI Refer to the Intel Modular Server System MFSYS25 MFSYS35 User Guide for information on using the Intel Modular Server Control Ul b Or connect a keyboard and monitor directly to the target compute module 2 Power on or reboot the compute module using either the Intel Modular Server Control Ul or by manually pressing the compute module power button 3 Press the lt F2 gt function key when the below message is displayed during boot time Press lt F2 gt to enter SETUP The message above is displayed after POST completes the memory test either below the BIOS splash screen if quiet boot is enabled or on the diagnostic screen if quiet
41. Intel Compute Module MFS5520VI User Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies Products Intel Order Number E60459 003 Disclaimer Information in this document is provided in connection with Intel products No license express or implied by estoppel or otherwise to any intellectual property rights is granted by this document Except as provided in Intel s Terms and Conditions of Sale for such products Intel assumes no liability whatsoever and Intel disclaims any express or implied warranty relating to sale and or use of Intel products including liability or warranties relating to fitness for a particular purpose merchantability or infringement of any patent copyright or other intellectual property right Intel products are not designed intended or authorized for use in any medical life saving or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur Intel may make changes to specifications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that need adequate airflow for cooling Intel s own chassis are designed and tested to meet the intended thermal requirements of these components when the fully integrated system is used together It is the responsibility of the system integrator that ch
42. Module MFS5520VI User Guide Aptio Setup Utility Copyright C 2009 American Megatrends Inc Set Throttling Mode Auto Figure 53 Advanced System Acoustics and Performance Configuration Screen Security The Security screen allows you to enable and set the user and administrative passwords This screen also allows you to enable and activate the Trusted Platform Module TPM security settings Intel Compute Module MFS5520VI User Guide 73 74 To access this screen from the Main screen press the right arrow key until the Security menu option is selected Aptio Setup Utility Copyright C 2009 American Megatrends Inc Set Administrator Password Figure 54 Security Screen Intel Compute Module MFS5520VI User Guide The following table describes the features of the Security screen Table 10 Security Screen Details Setup Item Options Description Administrator Password Status Information only Indicates the status of the administrator password Installed or Not Installed User Password Status Information only Indicates the status of the user password Installed or Not Installed Set Administrator Password 123aBcD An Administrator password is used to control change in access in the BIOS Setup utility Administrator access provides full access to all the setup options Only alphanumeric characters can be used The maximum length is 7 characters and it is case sensitiv
43. S Setup Utility n enonnnneennnneennneeesenreserrnsttenrnttnnntssttresttrnntrnnnnesttrnsetrnnnnnnn rennene 53 If You Cannot Access Setup ansehe 53 General Layout and Navigation u 53 An li aa 57 Ia 58 Advanced ee 60 DOCU snike dead aa eine i ee 73 Server Management ion ela Lai 76 BOOT OPTIONS EE iii tiara 81 Boot Manageriale res nine se oia 84 Error Manager u a ke ns 85 EX 86 Upgrading the BIOS A A o 88 Preparing for the Upgrade bi 88 Clearing the Password su ee 89 Cleaning THE OMS eis ei 92 Troubleshooting si anana aa aaa aa neiaa eini tadaa adian dianas iasa 95 First Steps Checklist een EE 95 Hardware Diagnostic Testing as na Aakre Ge dungete 96 Specific Problems and Corrective Actions pp 96 Power LED Does Not Ligh 00m n a AE EANA EAE A 97 No Video Display au rn ee e E iii 97 Characters are Distorted or Incorrect cece eeeaeeeeeeaeeeeeaaeeeeneeeeeaaeeseeeeeescaeeeseneeeeaas 97 No Available Storage u a nennen hassen de dan iii 97 Cannot Connect to a Compute Module iii 98 Problems with Newly Installed Application Software pp 98 Problems with Application Software that Previously Functioned Properly 99 Devices are Not Recognized within the Operating System pp 99 A Getting Help 0 NEE FRHPEREE REHEEREREREERPRERERRRFEAFRENNEERERTESRRERERREEEPREREFSRRERR 101 World Wide Web auch 101 Telephone anne u 101 Usssand Canada u He a ala ea 101 ET ee EE deen OCAR 101 In Asia P cific regi n 0000
44. S35 Technical Product Specification Available at http www intel com support motherboards server mfsys25 Accessories or other Intel server products Spares Parts List and Configuration Guide Available at http www intel com support motherboards server mfs5520vi or by using the Server Configurator Tool Available at http serverconfigurator intel com default aspx Intel Compute Module MFS5520VI User Guide For this information or software Use this Document or Software Hardware peripheral boards adapter cards and operating systems that have been tested with this product Processors that have been tested with this product DIMMSs that have been tested with this product Hard Drives that have been tested with this product Tested Product Lists Available at http www intel com support motherboards server mfs5520vi or by using Server Configurator Tool Available at http serverconfigurator intel com default aspx Latest drivers Unified Firmware Update packages and utilities Available for download at http www intel com support motherboards server mfs5520vi Click the Software and Drivers link on the left side of the web page For software to manage your Intel Modular Server System Intel Modular Server Control UI The Intel Management Module integrated management interface for the modular server system For instructions and information r
45. Stay Off compute module stays off Last State compute module returns to the same state before the AC power loss Reset compute module powers on Clear System Enabled If enabled this option clears the System Event Log Event Log Disabled All current entries are lost after saving changes and 182018 rebooting the compute module NOTE This option is reset to Disabled after a reboot FRB 2 Enable Enabled Fault Resilient Boot FRB Disabled If enabled the BIOS programs the BMC watchdog timer for approximately 6 minutes If the BIOS does not complete POST before the timer expires the BMC resets the compute module O S Boot Enabled BIOS programs the watchdog timer with the timeout Watchdog Disabled value selected If the OS does not complete booting Timer 190019 before the timer expires the BMC resets the compute module and an error is logged Requires OS support or Intel Management Software O S Boot Power Off If the OS watchdog timer is enabled this is the Watchdog R compute module action taken if the watchdog timer Timer Policy eset expires Reset Compute module performs a reset Power Off Compute module powers off NOTE This option is grayed out when O S Boot Watchdog Timer is disabled O S Boot 5 minutes If the OS watchdog timer is enabled this is the Watchdog 10 minut timeout value BIOS will use to configure the Timer Timeout minutes watchdog timer 15 minutes NOTE This option is grayed out when O S Boot
46. a puede extraer las tapas del sistema Para ello 1 Desbloquee y extraiga el bloqueo de seguridad de la parte posterior del sistema si se ha instalado uno 2 Extraiga y guarde todos los tornillos de las tapas Extraiga las tapas 140 Intel Compute Module MFS5520VI User Guide Para obtener un enfriamiento y un flujo de aire adecuados reinstale siempre las tapas del chasis antes de poner en marcha el sistema Si pone en funcionamiento el sistema sin las tapas bien colocadas puede dafiar los componentes del sistema Para instalar las tapas 1 Aseg rese primero de no haber dejado herramientas o componentes sueltos dentro del sistema 2 Compruebe que los cables las placas adicionales y otros componentes se hayan instalado correctamente 3 Incorpore las tapas al chasis mediante los tornillos extraidos anteriormente tens ndolos firmemente 4 Inserte el bloqueo de seguridad en el sistema y bloqu elo para impedir que pueda accederse al mismo sin autorizaci n 5 Conecte todos los cables externos y los cables de alimentaci n CA al sistema Si el sistema ha estado en funcionamiento el microprocesador y el disipador de calor pueden estar aun calientes Tambi n conviene tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes Por ello se recomienda precauci n y el uso de guantes protectores Existe peligro de explosi n si la pila no se cambia de forma adecuada Utilice
47. ados correctamente e Sujete las cubiertas a la carcasa siguiendo las instrucciones del producto Perif ricos o dispositivos l ser Precauci n Para evitar el riesgo de la exposici n a radiaciones o de da os personales e No abra la caja de ning n perif rico o dispositivo l ser Los perif ricos o dispositivos l ser no pueden ser reparados por el usuario Haga que el fabricante los repare 126 Intel Compute Module MFS5520VI User Guide Intel RAER Intel Intel P Bak Web IRA AH UL o MEER
48. age the screw threads by giving it two rotations in the clockwise direction and stop IMPORTANT Do not fully tighten b Proceed to the screw at location 2 and engage the screw threads by giving it two rotations and stop c Engage screws at locations 3 and 4 by giving each screw two rotations and then stop d Repeat steps 20a through 20c by giving each screw two rotations each time until all screws are lightly tightened upto a maximum of 8 inch Ibs torque Intel Compute Module MFS5520VI User Guide AF002841 Figure 26 Reinstalling Heatsink 31 Intel Compute Module MFS5520VI User Guide 32 Reinstalling Components 21 Reinstall the processor air duct AF003080 Figure 27 Reinstalling Processor Air Duct 22 Reinstall the top cover For instructions see Installing the Top Cover on page 16 23 Reinstall the server compute module in the chassis For instructions see Installing a Compute Module into the Chassis on page 14 Intel Compute Module MFS5520VI User Guide Installing and Removing Memory Modules Supported Memory The compute module provides support for up to twelve DIMMs across six memory channels three channels per processor DIMMs must be populated in pairs across consecutive channels starting with the lowest numbered slot in each channel Memory Map and Population Rules The nomenclature for DIMM sockets implemented on the Intel Compute Module MFS5520VI is detailed in the
49. annel mode both sockets must simultaneously satisfy the DIMM matching rules on their respective adjacent channels Ifthe DDR3 DIMMs on adjacent channels of a socket are not identical the BIOS configures both the processor sockets to default to the Independent Channel mode If DIMM D1 and DIMM EI are not identical then the compute module switches to the Independent Channel Mode Installing DIMMs DIMM slots are numbered as follows DIMM B2 DIMM B1 DIMM Al DIMM C2 DIMM A2 DIMM C1 o o SB 6 6 8 E Go O 9 do O Er E E E E E O og e 3 18 WE Tee 2 DIMM F1 L DIMM D2 DIMM F2 DIMM D1 DIMM El DIMM E2 AF003098 Figure 29 DIMM Slot Order Intel Compute Module MFS5520VI User Guide 36 To install DIMMs follow these steps 1 Observe the safety and ESD information at the beginning of this manual and in the Da appendices If the compute module is installed in a chassis remove it For instructions see Removing a Compute Module from the Chassis on page 13 Remove the top cover For instructions see Removing the Top C
50. assis on page 13 Remove the top cover For instructions see Removing the Top Cover on page 14 4 Remove the processor air duct see Figure 18 AF003080 Figure 18 Removing Processor Air Duct Intel Compute Module MFS5520VI User Guide 25 26 Removing the Heatsink 5 Loosen the four captive screws on the heatsink corners in a diagonal manner according to the numbers shown in Figure 19 as follows a Starting with the screw at location 1 loosen it by giving it two rotations in the anticlockwise direction see letter A in Figure 19 and stop IMPORTANT Do not fully loosen b Proceed to the screw at location 2 and loosen it by giving it two rotations and stop c Loosen screws at locations 3 and 4 by giving each screw two rotations and then stop d Repeat steps 5a through Sc by giving each screw two rotations each time until all screws are loosened Twist the heatsink slightly to break the seal between the heatsink and the processor Lift the heatsink from the processor see letter B in Figure 19 If it does not pull up easily twist the heatsink again Do not force the heatsink from the processor Doing so could damage the processor AF003123 Figure 19 Removing the Heatsink Removing the Old Processor 8 Push the lever handle down and away from the socket to release it see letter A in Figure 20 9 Rotate the lever open all the way see letter B in Figure 20 Intel
51. bled If Quiet Boot is enabled a logo screen is displayed Disabled during POST By default Quiet Boot is enabled in the BIOS setup If the logo is displayed during POST press lt Esc gt to hide the logo and display the diagnostic screen If a logo screen is not present in the flash ROM or if Quiet Boot is disabled the summary and diagnostic screen is displayed during POST POST Error Enabled If enabled the POST Error Pause option takes the Pause Disabled compute module to the error manager to review the critical POST errors when they occur Minor and fatal error displays are not affected by this setting If disabled the compute module attempts to boot and does not go to the Error Manager for critical POST errors System Date Day of week MM DD YYYY System Date has configurable fields for Month Day and Year Use Enter or Tab key to select the next field Use or key to modify the selected field System Time HH MM SS System Time has configurable fields for Hours Minutes and Seconds Hours are in 24 hour format Use the Enter or Tab key to select the next field Use the or key to modify the selected field Intel Compute Module MFS5520VI User Guide 59 Advanced The Advanced screen provides a list of categories that can be configured by the user The categories act as links to the specific configuration screens for each option Configuration changes are note perfor
52. board from its protective wrapper or from the server place the board component side up on a grounded static free surface Use a conductive foam pad if available but not the board wrapper Do not slide board over any surface Other Hazards Battery Replacement Caution There is the danger of explosion if the battery is incorrectly replaced When replacing the battery use only the battery recommended by the equipment manufacturer Dispose of batteries according to local ordinances and regulations Do not attempt to recharge a battery Do not attempt to disassemble puncture or otherwise damage a battery Cooling and Airflow Caution Carefully route cables as directed to minimize airflow blockage and cooling problems For proper cooling and airflow operate the chassis only with the chassis covers installed Operating the chassis without the covers in place can damage chassis parts To install the covers Check first to make sure you have not left loose tools or parts inside the chassis Check that cables add in boards and other components are properly installed e Attach the covers to the chassis according to the product instructions Laser Peripherals or Devices Caution To avoid risk of radiation exposure and or personal injury Do not open the enclosure of any laser peripheral or device Laser peripherals or devices have are not user serviceable 112 Intel Compute Module MFS5520VI User Guide Return to manufactur
53. c dez comme suit 1 Si un cadenas a t install sur l arri re du syst me d verrouillez le et retirez le 2 Retirez toutes les vis des panneaux et mettez les dans un endroit s r 3 Retirez les panneaux 138 Intel Compute Module MFS5520VI User Guide Afin de permettre le refroidissement et l a ration du syst me r installez toujours les panneaux du boitier avant de mettre le syst me sous tension Le fonctionnement du syst me en l absence des panneaux risque d endommager ses pi ces Pour installer les panneaux proc dez comme suit 1 Assurez vous de ne pas avoir oubli d outils ou de pi ces d mont es dans le syst me 2 Assurez vous que les c bles les cartes d extension et les autres composants sont bien install s 3 Revissez solidement les panneaux du bo tier avec les vis retir es plus t t 4 Remettez le cadenas en place et verrouillez le afin de pr venir tout acc s non autoris l int rieur du syst me 5 Rebranchez tous les cordons d alimentation c a et c bles externes au syst me Le microprocesseur et le dissipateur de chaleur peuvent tre chauds si le syst me a t sous tension Faites galement attention aux broches aigu s des cartes et aux bords tranchants du capot Nous vous recommandons l usage de gants de protection Danger d explosion si la batterie n est pas remont e correctement Remplacer uniquement avec une batterie du m me type ou d un ty
54. d alimentation secteur car ils servent de disjoncteur principal d alimentation du produit Pratiques de manipulation de l quipement R duisez le risque de dommages personnels ou mat riels Conformez vous aux exigences de m decine du travail et de s curit lorsque vous d placez et soulevez le mat riel Utilisez l assistance m canique ou toute autre assistance appropri e lorsque vous d placez et soulevez le mat riel Pour r duire le poids en vue de faciliter la manipulation retirez tout composant amovible Intel Compute Module MFS5520VI User Guide 119 Alimentation et avertissements en mati re d lectricit Attention Le bouton d alimentation indiqu par le symbole de mise en veille NE COUPE PAS completement l alimentation secteur du systeme car le courant de veille 5 V reste actif lorsque le systeme est sous tension Pour couper l alimentation du systeme vous devez debrancher le cordon d alimentation secteur de la prise murale Votre systeme peut utiliser plusieurs cordons d alimentation secteur Assurez vous que tous les cordons d alimentation sont debranches Vous devez les debrancher avant d ouvrir le ch ssis d ajouter ou de supprimer un composant non connectable a chaud Les alimentations de certains serveurs Intel sont munies de doubles fusibles p le neutre veuillez observer les precautions d usage afin d viter tout risque d el ctrocution N essayez pas de modifier ou d uti
55. d Blink Activity Hardware Requirements Processor Memory To avoid integration difficulties and possible board damage your server compute module must meet the requirements outlined below The Intel Compute Module MFS5520VI supports up to two Intel Xeon Processors 5500 series in FC LGA 1366 Socket B package with up to 95 W Thermal Design Power TDP 4 8 GT s 5 86 GT s and 6 4 GT s Intel QuickPath Interconnect Intel QPI Enterprise Voltage Regulator Down EVRD 11 1 The Intel Compute Module MFS5520VI supports six DDR3 memory channnels three per processor socket with two DIMMs per channel thereby supporting up to 12 DIMMs with dual processor sockets The compute module supports DDR3 1066 and DDR3 1333 memory technologies and supports both registered DIMMs RDIMMs and unbuffered DIMMs UDIMMs RDIMMs must be ECC only while UDIMMs can be ECC or non ECC Intel Compute Module MFS5520VI User Guide Power Supply A minimum of one 1000 Watt power supply is required to turn on a compute module One power supply supports one compute module plus all other modules in the chassis Two power supplies support two to three compute modules in any slot plus all other modules in the chassis Three power supplies support four to six compute modules in any slot plus all other modules in the chassis Any additional power supplies above the minimum required based on configuration provide redundancy
56. d replacing components It provides step by step instructions and diagrams for installing or replacing components such as the processors memory DIMMs and other components Chapter 3 provides information regarding the BIOS Setup Utility and how to update the compute module BIOS This section includes information on how to access and use the BIOS Setup Utility as well as update the compute module firmware using the Intel Modular Server Control UI and the latest Intel Modular Server System MFSYS25 MFSYS35 Unified Firmware Update UFU Chapter 4 provides information to assist you in troubleshooting the Intel Compute Module MFS5520VI This section also includes information on hardware diagnostics The back of this manual provides technical specifications regulatory information getting help information and the warranty Intel Compute Module MFS5520VI User Guide iii Intel Compute Module MFS5520VI User Guide Safety Information Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions See also Intel Server Boards and Server Chassis Safety Information at http support intel com support motherboards server sb cs 010770 htm Wichtige Sicherheitshinweise Lesen Sie zun chst s mtliche Warn und Sicherheitshinweise in diesem Dokument bevor Sie eine der Anweisungen ausf hren Beachten Sie hierzu auch die Intel Server Boards and Server Chassis Safety Infor
57. de If an installed DDR3 DIMM has faulty or incompatible SPD data it is ignored during memory initialization and is essentially disabled by the BIOS Ifa DDR3 DIMM has no SPD data or is missing SPD information the slot in which it is placed is treated as empty by the BIOS The DIMM parameter matching requirements for memory RAS is local to a socket For example while Channels A B C can have one match of timing technology and size Channels D E F can have a different set of parameters and RAS still functions DDR3 DIMMs on adjacent slots on the same channel do not need to be identical For the Mirrored Channel mode the memory in Channels A and B of Socket 1 must be identical and Channel C should be empty Similarly the memory in Channels D and E of Socket 2 must be identical and Channel F should be empty The minimum population upgrade for the Mirrored Channel mode is DIMM_AI DIMM_B1 DIMM_D1 and DIMM_EI with both processor sockets populated DIMM AI and DIMM B1 as a pair must be identical and so must DIMM_D1 and DIMM El but the DIMMs on different processor sockets do not need to be identical Failing to comply with these rules results in a switch back to the Independent Channel mode If Mirrored Channel mode is selected and the third channel of each processor socket is not empty the BIOS disables the memory in the third channel of each processor socket Intel Compute Module MFS5520VI User Guide Inthe Mirrored Ch
58. direction sets the BIOS option Quiet Boot to Disable The BIOS logo screen is not displayed during POST while console redirection is enabled 78 Intel Compute Module MFS5520VI User Guide To access this screen from the Main screen press the right arrow key until the Server Management menu option is selected then select Console Redirection Aptio Setup Utility Copyright C 2009 American Megatrends Inc Console Redirection Network Serial Con Figure 56 Server Management Console Redirection Enabled Screen Intel Compute Module MFS5520VI User Guide 79 The following table describes the features of the Console Redirection screen Table 12 Server Management Console Redirection Details Setup Item Options Description Console Disabled Console redirection allows a serial port to be used Redirection for server management tasks Network Serial Console If disabled the console redirection configuration options will not be displayed If set to Network Serial Console console redirection is enabled and the configuration options will be displayed NOTE Enabling this option will set Quiet Boot to disable The BIOS logo screen will not be displayed during POST while console redirection is enabled Flow Control None Flow control is the handshake protocol RTS CTS This setting must match the remote terminal application None Configure for no flow control RTS CTS Configure for hardware flow contro
59. dule from the Chassis To remove a compute module from the chassis follow these steps 1 Observe the safety and ESD information at the beginning of this manual and in the appendices 2 Ifthe compute module is operating shut down the operating system and power it down 3 Release the two retention levers by pressing on the release button located between the two lever handles Intel Compute Module MFS5520VI User Guide 13 4 Rotate the two lever handles outward and pull the compute module from the chassis slot 5 Place either a filler or another compute module into the bay within one minute This step is required to maintain proper airflow patterns throughout the chassis and to ensure proper chassis cooling Installing a Compute Module into the Chassis To install a compute module into the chassis follow these steps 1 Observe the safety and ESD information at the beginning of this manual and in the appendices 2 If you have not done so already install any necessary options such as processors memory hard drives and expansion cards in the compute module Note The top cover is a required component of the compute module do not attempt to insert a compute module into a chassis without a top cover installed Make sure the retention levers on the compute module are in the open position 4 Insert the compute module into an open slot in the chassis and slide it in until it stops 5 Close the retention lever handles on the
60. e Clearing the Administrator password also clears the user password NOTE An Administrator password must be set in order to enable the user account Set User Password 123aBcD The User password option is used to control entry access to the BIOS Setup utility only Set User Password is available only if the administrator password is installed The user password has limited access to the setup options This option only protects the setup Only alphanumeric characters can be used Maximum length is 7 characters and it is case sensitive NOTE Removing the administrator password also automatically removes the user password TPM State Enabled and Activated Enabled and Deactivated Disabled and Activated Disabled and Deactivated Information only This Shows the current TPM device state A disabled TPM device does not execute commands that use the TPM functions and TPM security operations are not available An enabled and deactivated TPM is in the same state as a disabled TPM except that setting of the TPM ownership is allowed if it is not present already An enabled and activated TPM executes all commands that use the TPM functions and TPM security operations are also available Intel Compute Module MFS5520VI User Guide 75 Table 10 Security Screen Details Setup Item Options Description TPM No Operation TPM Administrative control can be set to a pene Turn On No Operatio
61. e Module MFS5520VI User Guide 93 94 Intel Compute Module MFS5520VI User Guide 4 Troubleshooting This chapter provides information to assist you in troubleshooting the Intel Compute Module MFS5520VI A common cause of server function issues is outdated BIOS and BMC firmware and outdated operating system level device drivers Before performing extensive troubleshooting steps ensure that the BIOS and BMC firmware code and device drivers are up to date One of the first steps to perform in troubleshooting a compute module is to reboot the compute module Try resetting your compute module using one of the following methods Soft boot reset Shut down the operating system gracefully and restart the compute module to clear the memory and reload the operating system e Cold boot reset Turn the compute module power button off and then turn it back on to clear the memory restart POST reload the operating system and halt power to all peripherals First Steps Checklist e Are the compute module power LEDs on Isthe chassis properly connected to an AC power source e Are the power supplies fully seated in the chassis and the power cables fully seated in the power supplies e Is the compute module fully seated in the chassis Are the processors fully seated in their sockets on the server board Are the installed memory modules fully seated in their sockets on the server board e If installed is the add in mezzanine ca
62. e displayed in bold These values do not appear in bold on the BIOS Setup screen The bold text in this document is to serve as a reference point Changes except Date and Time made in the Setup Utility are not applied until they have been saved and the compute module has been rebooted Intel Compute Module MFS5520VI User Guide 57 Main The Main screen is the first screen that appears when the BIOS Setup is entered unless an error has occurred If an error has occurred the Error Manager screen is displayed instead Aptio Setup Utility Copyright C 2009 American Megatrends Inc Quiet Boot Disabled Figure 44 Main Screen 58 Intel Compute Module MFS5520VI User Guide Table 5 Main Screen Details The following table describes the features of the Main Setup screen Setup Item Options Description Logged in as Information only Displays the current BIOS Setup password level Administrator or User If no passwords are set Administrator is the default mode Platform ID Information only Displays the Platform ID S5520VI System BIOS Information only Displays the current BIOS Version version System BIOS Information only Displays the current BIOS Build Date build date Total Memory Information only Displays the total physical memory installed in the compute module in MB or GB The term physical memory indicates the total memory discovered in the form of installed DIMMs Quiet Boot Ena
63. e the CPU load plate all the way see letter A in Figure 15 17 Close the socket lever completely and ensure that the load plate tab engages under the socket lever when fully closed see letter B in Figure 15 AF002840 Figure 15 Closing the Load Plate Installing the Heatsink Caution Improper installation can damage the heatsink Pay close attention to the steps and perform each step exactly as indicated to avoid damage Caution The heatsink has Thermal Interface Material TIM located on the bottom of it Use caution when you unpack the heatsink so you do not damage the TIM Note New unused heatsinks have adequate TIM on the bottom If you are reusing a heatsink from replacing a processor make sure there is adequate TIM present on the heatsink to support processor cooling 18 Remove the protective film on the TIM if present 19 Orient the heatsink over the processor as shown in Figure 16 The heatsink fins must be positioned as shown to provide correct airflow through the system Airflow goes from front to back of the compute module 22 Intel Compute Module MFS5520VI User Guide Note Figure 16 illustrates the heatsink orientation for CPU 1 The heatsink over CPU 2 should be oriented in a reverse direction so as to provide correct airflow through the compute module 20 Set the heatsink over the processor lining up the four captive screws with the four posts surrounding the processor 21 Loosely scr
64. efer to the Intel Modular Server System MFSYS25 MFSYS35 User Guide Available at http www intel com support motherboards server mfsys25 Intel System Management Software Available at http www intel com go servermanagement Intel Compute Module MFS5520VI User Guide 11 Intel Compute Module MFS5520VI User Guide 2 Hardware Installations and Upgrades Before You Begin Before working with your server product review the safety and ESD information at the beginning of this manual and in the appendices Tools and Supplies Needed Phillips cross head screwdriver 1 bit and 2 bit e 1 4 inch nut driver e Anti static wrist strap and conductive foam pad recommended Installation Guidelines Before installing options 1 Observe the safety and ESD information at the beginning of this manual and in the appendices 2 Remove the compute module from the chassis Before doing so you must first shut down the operating system and turn off the compute module 3 Take note of the following color coding on components Blue on component indicates a touch point where you can grip the component to install or remove it from the server Green on a component indicates that the component may be hot swapped For a complete list of installation or removal steps see the instructions included with the hot swap component Removing and Installing an Intel Compute Module MFS5520VI Removing a Compute Mo
65. ements et mises en garde i 116 Domaines d utilisation pr vus iii 117 S lection d un emplacement iii 117 Pratiques de manipulation de l quipement nano cnn nn nn na nnn cananea 117 Alimentation et avertissements en mati re d lectricit erreren 118 Avertissements sur l acc s au systeme iii 118 D charges lectrostatiques ESD ss 119 AUTOS TISQUES u a ee keinen 119 Espangl A A 120 Informaci n de seguridad del servidor pp 120 Advertencias y precauciones sobre seguridad pp 120 Aplicaciones y USOS previst s nn ii ira 121 Selecci n de la ubicaci n iii 121 Manipulaci n del equipo cnc anna nana nn r arrancan rana nnnnncns 122 Advertencias de alimentaci n y el ctricas narran 122 Advertencias el acceso al sistema nn 122 Descarga electrost tica ESD iii ee 123 Otros peligros uva illa a al 124 D Installation Assembly Safety Instructions ee 131 Intel Compute Module MFS5520VI User Guide ix English ER EE EE AE EEE IE 131 DEUISCh SR a a a a 133 Eraneals onenen a a E E T a aa 136 ESPANDI zen anne 138 liano aaa 140 Intel Compute Module MFS5520VI User Guide List of Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Figure 22 Fig
66. en press the right arrow key until the Boot Options menu option is selected Aptio Setup Utility Copyright C 2009 American Megatrends Inc System Boot Timeout Figure 58 Boot Options Screen Intel Compute Module MFS5520VI User Guide Table 13 Boot Options Details The following table describes the features of the Boot Options screen Setup Item Options Help Text Boot Timeout 0 65535 The number of seconds BIOS will pause at the end of POST to allow the user to press the F2 key for entering the BIOS Setup utility Valid values are 0 65535 Zero is the default A value of 65535 causes the compute module to go to the Boot Manager menu and wait for user input for every boot These settings are in seconds After entering the desired timeout press the lt Enter gt key to register that timeout value Boot Option x Available boot Set system boot order by selecting the boot devices option for this position Network Device lt Enter gt Set network device boot order Order This option takes the user to a separate screen The Network Device Order screen which allows the user to select the boot order for the available network bootable devices Hard Disk lt Enter gt Set the hard disk drive boot order This option Order takes the user to a separate screen The Hard Disk Order screen which allows the user to select the boot order for the available bootable devices Delete B
67. er for servicing Deutsch Sicherheitshinweise f r den Server Das vorliegende Dokument bezieht sich auf Intel Serverplatinen Intel Servergeh use Standfu und Rack sowie installierte Peripherieger te Es enth lt Warnungen und Vorsichtsma nahmen zur Vermeidung von Gefahren durch Verletzung Stromschlag Feuer und Besch digungen von Ger ten Lesen Sie diese Dokument daher sorgf ltig bevor Sie Ihr Intel Serverprodukt installieren oder warten Bei Widerspr chen zwischen den hier vorliegenden Angaben und den Informationen im Lieferumfang des Produkts oder auf der Website des betreffenden Produkts hat die Produktdokumentation Vorrang Die Integration und Wartung des Servers darf nur durch technisch qualifizierte Personen erfolgen Um die Einhaltung der vorhandenen Zulassungen und Genehmigungen f r das Produkt zu gew hrleisten sind die Richtlinien in diesem Handbuch sowie die Montageanleitungen in den Serverhandb chern zu beachten Verwenden Sie nur die beschriebenen zugelassenen Komponenten die im vorliegenden Handbuch angegeben werden Die Verwendung anderer Produkte oder Komponenten f hrt zum Erl schen der UL Zulassung und anderer Genehmigungen f r das Produkt Dadurch kann das Produkt gegen Produktbestimmungen versto en die im Verkaufsland gelten Sicherheitshinweise und Vorsichtsma nahmen Um Verletzungen und Besch digungen zu vermeiden sollten Sie vor dem Beginn der Produktinstallation die nachfolgend aufgef
68. ess the inside of the power supply There are no serviceable parts in the power supply Return to manufacturer for servicing Power down the chassis and disconnect all power cords before adding or replacing any non hot plug component When replacing a hot plug power supply unplug the power cord to the power supply being replaced before removing the power supply from the chassis Caution Ifthe compute module has been running any installed processor s and heat sink s may be hot Unless you are adding or removing a hot plug component allow the compute module to cool before opening the covers To avoid the possibility of coming into contact Intel Compute Module MFS5520VI User Guide 111 with hot component s during a hot plug installation be careful when removing or installing the hot plug component s Caution To avoid injury do not contact moving fan blades If your chassis is supplied with a guard over the fan do not operate the chassis without the fan guard in place Electrostatic Discharge ESD Caution ESD can damage disk drives boards and other parts We recommend that you perform all procedures at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on your server when handling parts Always handle boards carefully They can be extremely sensitive to ESD Hold boards only by their edges After removing a
69. ew in the captive screws on the heatsink corners in a diagonal manner according to the numbers shown in Figure 16 as follows a Starting with the screw at location 1 engage the screw threads by giving it two rotations in the clockwise direction and stop IMPORTANT Do not fully tighten b Proceed to the screw at location 2 and engage the screw threads by giving it two rotations and stop c Engage screws at locations 3 and 4 by giving each screw two rotations and then stop d Repeat steps 21a through 21c by giving each screw two rotations each time until all screws are lightly tightened upto a maximum of 8 inch Ibs torque AF003122 Figure 16 Installing the Heatsink Reinstalling components 22 Reinstall the processor air duct Intel Compute Module MFS5520VI User Guide 23 24 AF003080 Figure 17 Reinstalling Processor Air Duct 23 Reinstall the top cover For instructions see Installing the Top Cover on page 16 24 Reinstall the server compute module in the chassis For instructions see Installing a Compute Module into the Chassis on page 14 Intel Compute Module MFS5520VI User Guide Replacing a Processor To replace a processor follow these steps 1 Observe the safety and ESD information at the beginning of this manual and in the appendices Removing Components 2 If the compute module is installed in a chassis remove it For instructions see Removing a Compute Module from the Ch
70. he Main screen press the right arrow key until the Advanced menu is selected then press the down or up arrow key to highlight PCI Configuration and press lt Enter gt Aptio Setup Utility Copyright C 2009 American Megatrends Inc Maximize Memory below 46B Disabled Figure 52 Advanced PCI Configuration Screen Intel Compute Module MFS5520VI User Guide 71 The following table describes the features of the Advanced PCI Configuration screen Table 9 Advanced PCI Configuration Details Setup Item Options Help Text Maximize Enabled If enabled BIOS maximizes usage of memory Memory below Disabled below 4 GB for an OS without PAE by limiting 4GB Same PCle Extended Configuration Space to 64 buses Memory Enabled Enable or disable memory mapped I O of 64 bit Mapped I O PCI devices to 4 GB or greater address space above 4GB Disabled Onboard NIC1 Enabled Load the embedded option ROM for the ROM onboard network controllers Disabled Warning If Disabled is selected NIC1 cannot be used to boot or wake the system Onboard NIC2 Enabled Load the embedded option ROM for the ROM onboard network controllers Disabled Warning If Disabled is selected NIC2 cannot be used to boot or wake the system NIC 1 MAC Information only 12 hex digits of the MAC Address address NIC 2 MAC Information only 12 hex digits of the MAC Address address System Acoustics and Performance Configuration 72
71. hr Server in Betrieb k nnen die installierten Prozessoren und K hlk rper hei sein Sofern Sie keine Hot Plug Komponenten ein oder ausbauen warten Sie mit dem Abnehmen der Abdeckungen bis das System abgek hlt ist Gehen Sie beim Aus oder Einbauen von Hot Plug Komponenten sorgf ltig vor um nicht mit hei en Komponenten in Ber hrung zu kommen Ber hren Sie nicht die rotierenden L fterfl gel um Verletzungen zu vermeiden Falls Ihr System mit eine L fterabdeckung besitzt darf es nicht ohne diese Abdeckung betrieben werden Elektrostatische Entladungen ESD 116 Vorsicht Elektrostatische Entladungen k nnen zur Besch digung von Festplatten Platinen und anderen Komponenten f hren Daher sollten Sie alle Arbeiten an einer ESD Workstation ausf hren Steht ein solcher Arbeitsplatz nicht zur Verf gung erzielen Sie einen gewissen Schutz vor elektrostatischen Entladungen durch Tragen einer Antistatik Manschette die Sie w hrend der Arbeit zur Erdung an einem beliebigen unlackierten Metallteil des Computergeh uses befestigen Gehen Sei bei der Handhabung von Platinen immer mit gr ter Vorsicht vor Sie k nnen u erst empfindlich gegen ber elektrostatischer Entladung sein Halten Sie Platinen nur an den Kanten fest Legen Sie die Platinen nach dem Auspacken aus der Schutzh lle oder nach dem Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete statisch entladene Unterlage Verwenden Sie dazu sofern ve
72. iliser la batterie Intel Compute Module MFS5520VI User Guide Domaines d utilisation pr vus Ce produit a t test comme quipement informatique ITE et peut tre install dans des bureaux des coles des salles informatiques et des endroits commerciaux similaires L utilisation du present produit dans des cat gories et environnements de produits et domaines d application par exemple le domaine m dical industriel r sidentiel les systemes d alarme et les appareils de contr le autres qu ITE doit faire l objet d valuations suppl mentaires S lection d un emplacement Le syst me est congu pour fonctionner dans un environnement standard de bureau Choisissez un emplacement respectant les conditions suivantes Propre sec et exempt de particules en suspension autres que la poussi re normale d une pi ce Bien ventil et l cart des sources de chaleur telles que la lumi re directe du soleil et les radiateurs l Ecart des sources de vibration ou des chocs physiques Isol des champs lectromagn tiques importants produits par des appareils lectriques Dans les regions sujettes aux orages magn tiques nous vous recommandons de brancher votre syst me un suppresseur de surtension et de d connecter les lignes de t l communication de votre modem pendant les orages Equip d une prise murale reli e la terre quip d un espace suffisant pour acc der aux cordons
73. ing Varoitus The lithium battery on the server board powers the RTC for up to 10 years in the absence of power When the battery starts to weaken it loses voltage and the server settings stored in the CMOS RAM for example the date and time may be wrong Contact your customer service representative or dealer for a list of approved replacement batteries Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the equipment manufacturer Discard used batteries according to manufacturer s instructions Lithiumbatteri Eksplosionsfare ved fejlagtig h ndtering Udskiftning m kun ske med batteri af samme fabrikat og type Lever det brugte batteri tilbage til leverand ren Lithiumbatteri Eksplosjonsfare Ved utskifting benyttes kun batteri som anbefalt av apparatfabrikanten Brukt batteri returneres apparatleverand ren Explosionsfara vid felaktigt batteribyte Anv nd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren Kassera anv nt batteri enligt fabrikantens instruktion Paristo voi r j ht jos se on virheellisesti asennettu Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiin H vit k ytetty paristo valmistajan ohjeiden mukaisesti To replace the battery follow these steps 1 Observe the safety and ESD information at the beginning of this manual and in the appendices 2 If the compute module is installed
74. ion Routez les c bles avec pr caution comme indiqu pour minimiser les blocages de circulation d air et les problemes de refroidissement Afin de permettre une ventilation et un refroidissement corrects ne mettez le systeme en marche que lorsque les panneaux du ch ssis sont en place L utilisation du systeme sans les panneaux peut endommager les composants systeme Pour installer les panneaux Intel Compute Module MFS5520VI User Guide 121 V rifiez tout d abord que vous n avez pas oubli d outils ou de composants d tach s l int rieur du systeme e V rifiez que les c bles les cartes d extension et les autres composants sont correctement install s e Fixez les panneaux au ch ssis en suivant les instructions du produit P riph riques laser Attention Pour viter tout risque d exposition aux rayonnements et ou de dommage personnel Espa ol e N ouvrez pas l enceinte d un p riph rique laser Les p riph riques laser ne sont pas r parables par l utilisateur e Retournez les au fabricant en cas de probl me Informaci n de seguridad del servidor Este documento se aplica a las tarjetas de servidor de Intel los gabinetes de servidor de Intel montaje en rack y en pedestal y los dispositivos perif ricos Para reducir el riesgo de dafios corporales descargas el ctricas fuego y en el equipo lea este documento y preste atenci n a todos las advertencias y precauciones de esta gu a
75. ion RAM The CMOS Clear jumper is located on jumper block J9A4 1 Power down the compute module 2 Remove the compute module from the Intel Modular Server System 3 Remove the compute module cover For instructions refer to Section Removing the Top Cover on page 14 4 Move the jumper J9A4 from the default operating position covering pins 1 and 2 to the reset clear position covering pins 2 and 3 CMOS Clear 3 2 lg Clear Default CMOS J9A4 AF003232 Figure 63 CMOS Clear Jumper 92 Intel Compute Module MFS5520VI User Guide Wait 5 10 seconds Move the jumper back to default position covering pins 1 and 2 Replace the compute module cover oo I OO Insert the compute module into the Intel Modular Server System 9 Power on the compute module The CMOS is now cleared and you can reset it by going into the BIOS setup Intel Comput
76. it Ifthe switch module is configured for multiple VLANS verify that the network cable is securely attached to the correct switch port Try a different network cable e Make sure you are using the correct and most current drivers e Make sure the operating system network settings are configured appropriately for the network the server is physically connected to Diagnostics Pass but Connection Fails e Make sure that an Ethernet switch is properly installed in the bay associated with the network interface card e Verify that the network driver is configured properly within the operating system Controller Stops Working when a Mezzanine Card is Installed Verify that the compute module BIOS and firmware on board network interface card firmware and mezzanine card firmware are all current Try re seating the mezzanine card Mezzanine Card Stops Working Without Apparent Cause Try re seating the mezzanine card e The network driver files may be corrupt or deleted Try re installing the drivers Problems with Newly Installed Application Software Check the following e Make sure the compute module meets the minimum hardware requirements for the software See the software documentation e Make sure the software is properly installed and configured for the compute module See the software documentation 98 Intel Compute Module MFS5520VI User Guide Use only an authorized copy Unauthorized copies often do not wo
77. l Baud Rate 9600 Serial port transmission speed This setting must match the remote terminal application 19 2K 38 4K 57 6K 115 2K Terminal Type PC ANSI Character formatting used for console redirection VT100 This setting must match the remote terminal application VT100 VT UTF8 Legacy OS Disabled This option enables legacy OS redirection that is Redirection Enabled DOS on serial port If it is enabled the associated serial port is hidden from the legacy OS System Information 80 The System Information screen provides the following information for the compute module Board part number Board serial number Asset tag BMC firmware revision SDR revision UUID Intel Compute Module MFS5520VI User Guide To access this screen from the Main screen press the right arrow key until the Server Management menu option is selected then press the down or up arrow key to highlight System Information and press lt Enter gt Aptio Setup Utility Copyright C 2009 American Megatrends Inc Figure 57 Server Management System Information Screen Boot Options The Boot Options screen displays any bootable media encountered during POST and allows you to configure the desired order in which boot devices are to be tried The first boot device in the specified boot order will be used to boot the compute module Intel Compute Module MFS5520VI User Guide 81 82 To access this screen from the Main scre
78. ler empfohlenen Batterietyp ersetzt werden Entsorgen Sie verbrauchte Batterien den Anweisungen des Herstellers entsprechend 136 Intel Compute Module MFS5520VI User Guide Das System wurde f r den Betrieb in einer normalen B roumgebung entwickelt Der Standort sollte sauber und staubfrei sein Hausstaub ausgenommen gut gel ftet und keinen Heizquellen ausgesetzt sein einschlie lich direkter Sonneneinstrahlung keinen Ersch tterungen ausgesetzt sein keine starken von elektrischen Ger ten erzeugten elektromagnetischen Felder aufweisen in Regionen in denen elektrische St rme auftreten mit einem Uberspannungsschutzger t verbunden sein w hrend eines elektrischen Sturms sollte keine Verbindung der Telekommunikationsleitungen mit dem Modem bestehen mit einer geerdeten Wechselstromsteckdose ausger stet sein ber ausreichend Platz verf gen um Zugang zu den Netzkabeln zu gew hrleisten da der Stromanschlu des Produkts haupts chlich ber die Kabel unterbrochen wird Intel Compute Module MFS5520VI User Guide 137 Francais Le bloc d alimentation de ce produit ne contient aucune piece pouvant amp tre r par e par l utilisateur Ce produit peut contenir plus d un bloc d alimentation Veuillez contacter un technicien qualifi en cas de probl me Ne pas essayer d utiliser ni modifier le c ble d alimentation CA fourni s il ne correspond pas exactement au type requis
79. liere le coperture 142 Intel Compute Module MFS5520VI User Guide Per il giusto flusso dell aria e raffreddamento del sistema rimettere sempre le coperture del telaio prima di riaccendere il sistema Operare il sistema senza le coperture al loro proprio posto potrebbe danneggiare i componenti del sistema Per rimettere le coperture del telaio 1 Controllare prima che non si siano lasciati degli attrezzi o dei componenti dentro il sistema 2 Controllare che i cavi dei supporti aggiuntivi ed altri componenti siano stati installati appropriatamente 3 Attaccare le coperture al telaio con le viti tolte in precedenza e avvitarle strettamente 4 Inserire e chiudere a chiave il lucchetto sul retro del sistema per impedire l accesso non autorizzato al sistema 5 Ricollegare tutti i cavi esterni e le prolunghe AC del sistema Se il sistema stato a lungo in funzione il microprocessore e il dissipatore di calore potrebbero essere surriscaldati Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio E consigliabile l uso di guanti di protezione Esiste il pericolo di un esplosione se la pila non viene sostituita in modo corretto Utilizzare solo pile uguali o di tipo equivalente a quelle consigliate dal produttore Per disfarsi delle pile usate seguire le istruzioni del produttore Il sistema progettato per funzionare in un ambiente di lavoro tipo Scegliere una p
80. liser un cordon d alimentation secteur s il ne s agit pas du type exact requis Un cordon secteur est requis pour chaque alimentation syst me Le bloc d alimentation de ce produit ne contient aucun composant r parable par Vutilisateur N ouvrez pas le bloc d alimentation L interieur de celui ci est soumis des niveaux dangereux de tension de courant et d nergie Renvoyez le au fabricant en cas de probleme Lorsque vous remplacez un bloc d alimentation a chaud debranchez le cordon du bloc d alimentation en cours de remplacement avant de le retirer du serveur Pour viter tout risque d electrocution mettez le systeme hors tension et debranchez les cordons d alimentation ainsi que les systemes de telecommunication reseaux et modems reli s au systeme avant d ouvrir ce dernier Avertissements sur l acc s au syst me Attention Pour viter de vous blesser ou d endommager votre quipement les consignes de s curit 120 suivantes s appliquent chaque fois que vous acc dez l int rieur du produit e Mettez hors tension tous les p riph riques connect s ce produit e teignez le syst me en appuyant sur le bouton d alimentation e D connectez l alimentation secteur en debranchant tous les cordons d alimentation secteur du syst me ou de la prise murale D connectez l ensemble des c bles et lignes de t l communication qui sont connect s au syst me Mettez toutes les vis ou au
81. mation unter http support intel com support motherboards server sb cs 010770 htm Consignes de s curit Lisez attention toutes les consignes de s curit et les mises en garde indiqu es dans ce document avant de suivre toute instruction Consultez Intel Server Boards and Server Chassis Safety Information sur le site http support intel com support motherboards server sb cs 010770 htm Instrucciones de seguridad importantes Lea todas las declaraciones de seguridad y Prag de este documento antes de realizar cualquiera de las instrucciones Vea Intel Server Boards and Server Chassis Safety Information en http support intel com support motherboards server sb cs 010770 htm http support intel com support motherboards server sb CS 010770 htm Intel Server Boards and Server Chassis Safety Information Intel Intel Compute Module MFS5520VI User Guide V Warnings vi These warnings and cautions apply whenever you remove the compute module enclosure cover to access components inside the chassis Only a technically qualified person should maintain or configure the chassis Heed safety instructions Before working with your server product whether you are using this guide or any other resource as a reference pay close attentio
82. med directly on the Advanced screen To access this screen from the Main screen press the right arrow key until the Advanced menu option is selected Aptio Setup Utility Copyright C 2009 American Megatrends Inc gt Processor Configuration Figure 45 Advanced Screen The following sections provide detailed information including images of the configuration screens for each of the categories listed on the Advanced menu Processor Configuration The Processor Configuration screen allows you to view detailed information for each installed processor as well as configure several processor options 60 Intel Compute Module MFS5520VI User Guide To access this screen from the Main screen press the right arrow key until the Advanced menu option is selected then select Processor Configuration from the Advanced menu Aptio Setup Utility Copyright C 2009 American Megatrends Inc Intel R Turbo Boost Technology Enabled Figure 46 Advanced Processor Configuration Screen Intel Compute Module MFS5520VI User Guide 61 The following table describes the features of the Advanced Processor Configuration screen Table 6 Advanced Processor Configuration Details 62 Setup Item Options Description Processor Title Configuration Processor Separates processor socket CPU1 and CPU2 Socket information into two columns for the page layout Processor ID Information only Process
83. mientras el sistema est enchufado Para desconectar el sistema debe desenchufar el cable de alimentaci n de CA de la toma de la pared Puede usar m s de un cable de alimentaci n de CA con el sistema Aseg rese de que todos los cables de alimentaci n de CA est n desenchufados Aseg rese de que los cables de alimentaci n de CA est n desenchufado antes de abrir le gabinete agregar o extraer cualquier componente que no es de conexi n en funcionamiento Algunas fuentes de alimentaci n de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje Para evitar riesgos de choques el ctricos use precauciones al trabajar con las fuentes de alimentaci n que utilizan el polo neutral de fuselaje No intente modificar ni utilizar un cable de alimentaci n de CA si no es del tipo exacto requerido Se necesita un cable de CA para cada fuente de alimentaci n del sistema La fuente de alimentaci n de este producto no contiene piezas que puedan ser reparadas por el usuario No abra la fuente de alimentaci n Dentro de la fuente de alimentaci n puede haber niveles de tensi n corriente y energ a peligrosos Devu lvala al fabricante para repararla Al reemplazar una fuente de alimentaci n de conexi n en funcionamiento desenchufe el cable de alimentaci n de la fuente de alimentaci n que va a reemplazar antes de extraerla del servidor Para evitar el riesgo de descargas el ctricas antes de abrir el servidor ap guelo de
84. modes are supported Independent Channel Mode and Mirrored Channel Mode Intel Compute Module MFS5520VI User Guide 33 The memory slots of each DDR3 channel from the Intel Xeon processor 5500 series are populated on a farthest first fashion This holds true even for the Independent Channel mode Therefore if Al is empty A2 cannot be populated or used The BIOS selects the Independent Channel mode by default which enables all installed memory on all channels simultaneously Mirrored Channel mode is not available when only one processor is populated CPU Socket 1 If both processor sockets are populated and the installed DIMMs are associated with both processor sockets then a given RAS mode is selected only if both the processor sockets are populated to conform to that mode The minimum memory population possible is one DIMM in slot A1 In this configuration the compute module operates in the Independent Channel mode RAS is not available If both processor sockets are populated the next upgrade from the Single Channel mode installs DIMM_D1 This configuration results in an optimal memory thermal spread as well as Non Uniform Memory Architecture NUMA aware interleaving The BIOS selects the Independent Channel mode of operation If only one processor socket is populated the next upgrade from the Single Channel mode is installing DIMM_BI to allow channel interleaving The compute module operates in the Independent Channel mo
85. mory is configured for optimal performance and efficiency and no RAS is enabled Mirror Mode System memory is configured for maximum reliability in the form of memory mirroring Current Information only Displays the speed at which the Memory Speed memory is running Memory RAS Select to configure memory RAS Reliability Availability and and Serviceability and view current memory Performance performance information and settings This takes the Configuration user to a different screen DIMM XY Displays the state of each DIMM socket present on the board Each DIMM socket field reflects one of the following possible states Installed There is a DIMM installed in this slot Not Installed There is no DIMM installed in this slot Disabled The DIMM installed in this slot has been disabled by the BIOS in order to optimize memory configuration Failed The DIMM installed in this slot is faulty malfunctioning Note X denotes the Channel Identifier and Y denotes the DIMM Identifier within the Channel Memory RAS and Performance Configuration The Memory RAS Reliability Availability and Serviceability and Performance Configuration screen displays current memory performance information and settings Under capabilities this screen displays whether memory mirroring is possible Yes No and allows the user to enable or disable NUMA optimization Intel Compute Module MFS5520VI User Guide To access this screen f
86. mpute Module MFS5520VI User Guide 19 Installing the Processor 8 Locate the processor socket 9 Push the lever handle down and away from the socket to release it see letter A in Figure 10 10 Rotate the lever open all the way see letter B in Figure 10 NN AF002835 Figure 10 Lifting the Processor Socket Lever 11 Push the rear tab with your finger tip to bring the front end of the load plate open slightly see letter A in Figure 11 12 Open the load plate see letter B in Figure 11 Figure 11 Opening the Load Plate 13 Remove the protective socket cover see Figure 12 Note Do not touch the socket pins they are very sensitive and easily damaged Note Retain the protective socket cover for use when removing a processor that will not be replaced 20 Intel Compute Module MFS5520VI User Guide AF002837 Figure 12 Removing the Protective Socket Cover 14 Remove the processor from the packaging box and remove the protective shipping cover see Figure 13 AF002838 Figure 13 Removing the Processor Protective Cover 15 Orient the processor with the socket so that the processor cutouts match the two socket pins and insert the processor into the socket see Figure 14 Intel Compute Module MFS5520VI User Guide 21 AF002839 Figure 14 Installing the Processor Note Make sure the alignment triangle mark and the alignment triangle cutout align correctly 16 Clos
87. n No changes to current state Turn Off Turn On Enables and activates TPM Clear Turn Off Disables and deactivates TPM Ownership Clear Ownership Removes the TPM ownership authentication and returns the TPM to the factory default state NOTE The BIOS setting returns to No Operation on every boot cycle by default Server Management The Server Management screen allows you to configure several server management features This screen also provides an access point to the screens for configuring console redirection and displaying system information To access this screen from the Main screen press the right arrow key until the Server Management menu option is selected Aptio Setup Utility Copyright C 2009 American Megatrends Inc Assert NMI on SERR Enabled Figure 55 Server Management Screen 76 Intel Compute Module MFS5520VI User Guide The following table describes the features of the Server Management screen Table 11 Server Management Screen Details Setup Item Options Description Assert NMI on Enabled On SERR generate an NMI and log an error SERR i Disabled Assert NMI on Enabled On PERR generate an NMI and log an error PERR Disabled NOTE This option is only active if the Assert NMI on SERR option is Enabled selected Resume on AC Stay Off Set the compute module action to take on AC power Power Loss loss recovery Last state Reset
88. n Sie vor dem ffnen des Ger ts das Netzkabel sowie alle an den Server angeschlossene Telekommunikationssysteme Netzwerke und Modems Warnhinweise f r den Systemzugang Vorsicht Um Verletzungen und Besch digungen zu vermeiden sollten Sie vor Arbeiten im Produktinneren folgende Sicherheitsanweisungen beachten e Schalten Sie alle am Produkt angeschlossenen Peripherieger te aus e Schalten Sie das System mit dem Netzschalter aus e Trennen Sie das Ger t von der Stromquelle indem Sie alle Netzkabel vom System bzw aus der Steckdose ziehen Ziehen Sie alle Kabel und alle an das System angeschlossenen Telekommunikationsleitungen ab e Bewahren Sie alle Schrauben und anderen Befestigungselemente gut auf nachdem Sie die Geh useabdeckung entfernt haben Wenn Sie Ihre Arbeiten im Systeminneren beendet haben befestigen Sie die Geh useabdeckung mit den Originalschrauben bzw befestigungselementen e F hren Sie keine Arbeiten im Netzteil aus Das Netzteil enth lt keine f r den Benutzer wartungsbed rftigen Teile Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck e Schalten Sie den Server aus und ziehen Sie alle Netzkabel ab bevor Sie Komponenten ein oder ausbauen die nicht hot plug f hig sind Intel Compute Module MFS5520VI User Guide 115 Vorsicht Vorsicht e Wenn Sie ein hot plug f higes Netzteil austauschen ziehen Sie dessen Netzkabel ab bevor Sie es aus dem Server ausbauen War I
89. n to the safety instructions You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region s in which the product is sold Compute module power on off The power button turns off only DC power to the compute module standby power is still present in the compute module To remove all power from the compute module uninstall or remove the compute module from the chassis Hazardous conditions devices and cables Hazardous electrical conditions may be present on power telephone and communication cables Turn off the chassis and disconnect the power cord telecommunications systems networks and modems attached to the chassis before opening it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage disk drives boards and other parts We recommend that you perform all procedures in this document only at an ESD workstation If one is not available provide some ESD protection by wearing an anti static wrist strap attached to chassis ground any unpainted metal surface on your chassis when handling parts ESD and handling electronic devices
90. nto the Intel Modular Server System the compute module s BIOS and firmware is automatically updated to the installed UFU version For detailed step by step instructions on how to upgrade the Intel Compute Module BIOS and firmware refer to the UFU release notes Preparing for the Upgrade The following steps explain how to prepare to upgrade the BIOS and include how to Record the current BIOS settings e Obtain the upgrade utility Recording the Current BIOS Settings 1 Boot the compute module and press lt F2 gt when you see the message Press lt F2 gt to enter SETUP 2 Write down the current settings in the BIOS Setup Utility Note Do not skip step 2 You need these settings to configure your compute module at the end of the procedure Obtaining the Upgrade Download the Intel Modular Server System MFSYS25 MFSYS35 Unified Firmware Update UFU package to a temporary folder on your hard drive or a USB flash device See Additional Information and Software for a link to the update software Note Before attempting a system firmware update review the release notes distributed with the UFU package The release notes may contain critical information regarding specific fixes or other information to complete the update Updating the BIOS The Intel Compute Module MFS5520VI BIOS and firmware update is performed as a part of the Intel Modular Server System MFSYS25 MFSYS35 Unified Firmware Update process The Unified Firm
91. nweise ffnen Sie keinesfalls das Geh use von Laser Peripherieger ten oder Laser Komponenten Laser Peripherieger te oder Komponenten besitzen keine f r den Benutzer wartungsbed rftigen Teile e Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Intel Compute Module MFS5520VI User Guide 117 Francais Consignes de s curit sur le serveur Ce document s applique aux cartes serveur Intel au ch ssis de serveur Intel sur pieds et sur rack et aux p riph riques install s Pour r duire les risques de dommages corporels d lectrocution d incendie et de dommages mat riels lisez ce document et respectez tous les avertissements et pr cautions mentionn s dans ce guide avant d installer ou de mettre jour votre produit serveur Intel En cas de conflit entre les informations fournies dans ce document et celles livr es avec le produit ou publi es sur le site Web pour un produit particulier la documentation du produit prime Votre serveur doit tre int gr et entretenu uniquement par des techniciens qualifi s Vous devez suivre les informations de ce guide et les instructions d assemblage des manuels de serveur pour v rifier et maintenir la conformit avec les certifications et approbations de produit existantes Utilisez uniquement les composants d crits et r glement s sp cifi s dans ce guide L utilisation d autres produits composants annulera la liste UL et les au
92. odule MFS5520VI User Guide B Product Regulatory Requirements Regulatory and Certification Information The Intel Compute Module MFS5520VI is evaluated as part of the Intel Modular Server System MFSYS25 MFSYS35 which requires meeting all applicable system component regulatory requirements Refer to the Intel Modular Server System MFSYS25 MFSYS35 User Guide for a complete listing of all system and component regulatory requirements Product Regulatory Compliance and Safety Markings No markings are required on the Intel Compute Module MFS5520VI itself as it is evaluated as part of the Intel Modular Server System MFSYS25 MFSYS35 Product Environmental Ecology Requirements The Intel Compute Module MFS5520VI is evaluated as part of the Intel Modular Server System MFSYS25 MFSYS35 which requires meeting all applicable system component environmental and ecology requirements For a complete listing of all system and component environment and ecology requirements and markings refer to the Intel Modular Server System MFSYS25 MFSYS35 User Guide Product Environmental Ecology Markings The following Product Ecology markings are required on the Intel Compute Module MFS5520VI Requirement Country Marking China Restriction of Hazardous Substance Environmental Friendly Use Period Mark China e Intel Compute Module MFS5520VI User Guide 107 108 Intel Compute Module MFS5520VI U
93. ooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions Intel Corporation can not be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non operating limits Intel Intel Pentium and Intel Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Other names and brands may be claimed as the property of others Copyright 2008 2009 Intel Corporation All Rights Reserved Preface About this Manual Thank you for purchasing and using the Intel Compute Module MFS5520VI This manual is written for system technicians who are responsible for troubleshooting upgrading and repairing compute modules This document provides reference information feature information and step by step instructions for adding and replacing components in the compute module For the latest version of this manual see http www intel com support motherboards server MFS5520VI Manual Organization Chapter 1 provides a brief overview of the compute module This includes a list of the compute module features illustrations of the product and product diagrams to help you identify components and their locations Chapter 2 provides instructions for adding an
94. oot lt Enter gt Remove an EFI boot option from the boot order Option This option takes the user to a new screen titled Delete Boot Option This new screen allows the user to select an EFI boot option from the boot order for deletion If the EFI shell is deleted it is restored on the next compute module reboot It cannot be permanently deleted EFI Optimized Enabled If enabled the BIOS will only load modules Boot required for booting EFl aware Operating Disabled Systems Boot Option Enabled This will continually retry non EFl based boot Retry Disabled options without waiting for user input USB Boot Enabled If enabled newly discovered USB devices will be Priority Disabled put to the top of their boot device category If disabled newly discovered USB devices will be put at the bottom of their boot device catergory Intel Compute Module MFS5520VI User Guide 83 Boot Manager The Boot Manager screen allows you to view a list of devices available for booting and to select a boot device for immediately booting the compute module This list is not displayed in the order configured on the Boot Options menu Use the Boot Options menu to view and configure the compute module boot option order To access this screen from the Main screen press the right arrow key until the Boot Manager menu option is selected Aptio Setup Utility Copyright C 2009 American Megatrends Inc 0400 ID03 LUNO Intel Multi Fig
95. or CPUID Processor Information only Current frequency of the processor Frequency Microcode Information only Revision of the loaded microcode Revision L1 Cache RAM Information only Size of the Processor L1 Cache L2 Cache RAM Information only Size of the Processor L2 Cache L3 Cache RAM Information only Size of the Processor L3 Cache Processor 1 Information only ID string from the Processor Version Processor 2 Information only ID string from the Processor Version Current Intel Information only Current speed used by the QPI QPI Link Speed Link Intel QPI Link Information only Current frequency used by the QPI Frequency Link Intel Turbo Enabled Intel Turbo Boost Technology allows the processor Boost Disabled to automatically increase its frequency if it is running Technology pale below power temperature and current specifications Enhanced Intel Enabled Enhanced Intel SpeedStep Technology allows the SpeedStep Te Disabled system to dynamically adjust processor voltage and chnology SANE core frequency which can result in decreased average power consumption and decreased average heat production Contact your OS vendor regarding OS support of this feature Intel Hyper Enabled Intel Hyper Threading Technology allows multi Threading Tech Disabled threaded software applications to execute threads in BADE parallel within each processor Contact your OS vendor regarding OS support of this feature Core Multi All Enable 1
96. ostazione che sia LE e Pulita e libera da particelle in sospensione a parte la normale polvere presente nell ambiente i N Ben ventilata e lontana da fonti di calore compresa la luce solare diretta Al riparo da urti e lontana da fonti di vibrazione e Isolata dai forti campi magnetici prodotti da dispositivi elettrici In aree soggette a temporali consigliabile collegare il sistema ad un limitatore di corrente In caso di temporali scollegare le linee di comunicazione dal modem Dotata di una presa a muro correttamente installata e Dotata di spazio sufficiente ad accedere ai cavi di alimentazione i quali rappresentano il mezzo principale di scollegamento del sistema Intel Compute Module MFS5520VI User Guide 143 144 Intel Compute Module MFS5520VI User Guide
97. over on page 14 Remove the processor air duct see Figure 30 10 11 AF003080 Figure 30 Removing Processor Air Duct Locate the DIMM sockets Holding the DIMM by the edges remove it from the package Make sure the clips at either end of the DIMM socket s are pushed outward to the open position see letter A in Figure 31 Holding the DIMM by the edges remove it from its anti static package Position the DIMM above the socket Align the notch on the bottom edge of the DIMM with the key in the DIMM socket see letter B in Figure 31 the arrow is pointing to the key in the socket Insert the bottom edge of the DIMM into the socket When the DIMM is correctly positioned push down on the top edge of the DIMM until the retaining clips snap into place see letter C in Figure 31 Intel Compute Module MFS5520VI User Guide 12 Make sure the clips are firmly in place see letter D in Figure 31 Important Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot see letter E in Figure 31 DIMM B2 DIMM A1 m DIMM B1 DIMM C2 DIMM C1 MIT oo ee o o BD DIMM F1 L DIMM D2 DIMM F2 DIMM D1 DIMM
98. packaging Indicates the presence of a hazard that may cause minor personal injury or CAUTION property damage if the CAUTION is ignored Indicates the presence of a hazard that may result in serious personal injury if WARNING the WARNING is ignored Indicates potential hazard if indicated information is ignored Indicates shock hazards that result in serious injury or death if safety instructions are not followed Indicates hot components or surfaces amp Indicates do not touch fan blades may result in injury Intel Compute Module MFS5520VI User Guide 109 aa Indicates to unplug all AC power cord s to disconnect AC power Please recycle battery Es Intended Application Uses This product was evaluated as Information Technology Equipment ITE which may be installed in offices schools computer rooms and similar commercial type locations The suitability of this product for other product categories and environments such as medical industrial residential alarm systems and test equipment other than an ITE application may require further evaluation Site Selection The compute module is designed to operate in a typical office environment Choose a site that is e Clean dry and free of airborne particles other than normal room dust e Well ventilated and away from sources of heat including direct sunlight and radiators Away from sources of vibration or physical shock e
99. pe quivalent recommand par le fabricant Disposez des piles us es selon les instructions du fabricant Le syst me a t con u pour fonctionner dans un cadre de travail normal L emplacement choisi doit tre e Propre et d pourvu de poussi re en suspension sauf la poussi re normale Bien a r et loin des sources de chaleur y compris du soleil direct A l abri des chocs et des sources de vibrations e Isol de forts champs lectromagn tiques g en r s par des appareils lectriques Dans les r gions sujettes aux orages magn tiques il est recomand de brancher votre syst me un supresseur de surtension et de d brancher toutes les lignes de t l communications de votre modem durant un orage Muni d une prise murale correctement mise la terre e Suffisamment spacieux pour vous permettre d acc der aux c bles d alimentation ceux ci tant le seul moyen de mettre le syst me hors tension Intel Compute Module MFS5520VI User Guide 139 Espanol El usuario debe abstenerse de manipular los componentes de la fuente de alimentaci n de este producto cuya reparaci n debe dejarse exclusivamente en manos de personal t cnico especializado Puede que este producto disponga de m s de una fuente de alimentaci n No intente modificar ni usar el cable de alimentaci n de corriente alterna si no corresponde exactamente con el tipo requerido El numero de cables suminist
100. pute Module MFS5520VI is shown in the following pictures AF003075 Figure 1 Intel Compute Module MFS5520VI Intel Compute Module MFS5520VI User Guide Figure 2 Server Board Intel Compute Module MFS5520VI User Guide Feature Overview The following table summarizes the major features of the compute module Table 1 Compute Module Features Feature Description Processor Support for one or two Intel Xeon Processors 5500 Series in FC LGA 1366 Socket B package with up to 95 W Thermal Design Power TDP 4 8 GT s 5 86 GT s and 6 4 GT s Intel QuickPath Interconnect Intel QPI Enterprise Voltage Regulator Down EVRD 11 1 Memory Twelve DIMMs across six memory channels three channels per processor Support for 1066 1333 MT s ECC registered RDIMM or unbuffered UDIMM DDR3 memory Chipset Intel 5520 Chipset I O Hub Intel 82801Jx I O Controller Hub Video On board ServerEngines LLC Pilot II Controller Integrated 2D Video Controller 32 MB DDR2 Memory LAN One 10 100 1000 Intel 82575 Gigabit Ethernet Controller Hard Drive LSI 1064e SAS Controller Server Management On board ServerEngines LLC Pilot II Controller Integrated Baseboard Management Controller Integrated BMC IPMI 2 0 compliant Integrated Super I O on LPC interface Intel Compute Module MFS5520VI User Guide Connector and Component Locations AF003077 Intel 552
101. rados se corresponden con el n mero de fuentes de alimentaci n de corriente alterna que tenga el producto N tese que el interruptor activado desactivado en el panel frontal no desconecta la corriente alterna del m dulo de computaci n Para desconectarla deber desenchufar todos los cables de corriente alterna de la pared o desconectar la fuente de alimentaci n Estos cables act an como dispositivo de desconexi n La toma de corriente deber estar situada cerca del equipo y ser de facil acceso INSTRUCCIONES DE SEGURIDAD Cuando extraiga la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos perif ricos conectados al sistema 2 Apague el m dulo de computaci n presionando el interruptor encendido apagado 3 Desconecte todos los cables de alimentaci n CA del sistema o de las tomas de corriente alterna 4 Identifique y desconecte todos los cables enchufados a los conectores E S o a los puertos situados en la parte posterior del sistema 5 Cuando manipule los componentes es importante protegerse contra la descarga electrost tica ESD Puede hacerlo si utiliza una mufequera antiest tica sujetada a la toma de tierra del chasis 0 a cualquier tipo de superficie de metal sin pintar 6 No ponga en marcha el sistema si se han extrafdo las tapas del chasis Despu s de completar las seis instrucciones de SEGURIDAD mencionadas y
102. rboards server Telephone All calls are billed US 25 00 per incident levied in local currency at the applicable credit card exchange rate plus applicable taxes Intel reserves the right to change the pricing for telephone support at any time without notice For an updated support contact list see http www intel com support 9089 htm U S and Canada Europe 1 800 404 2284 Belgium 02 714 3182 Denmark 38 487077 Finland 9 693 79297 France 01 41 918529 Germany 069 9509 6099 Holland 020 487 4562 Taly us meriton 02 696 33276 Norway 23 1620 50 Russia 7 495 642 8537 Spain 91 377 8166 Sweden 08 445 1251 United Kingdom 0870 607 2439 Intel Compute Module MFS5520VI User Guide 101 In Asia Pacific region Japan Australia 1800 649931 Cambodia 63 2 636 9797 via Philippines China 800 820 1100 toll free sa 8 621 33104691 not toll free Hong Kong 852 2 844 4456 India 0006517 2 68303634 manual toll free You need an IDD equipped telephone Indonesia 803 65 7249 Korea 822 767 2595 Malaysia 1 800 80 1390 Myanmar 63 2 636 9796 via Philippines New Zealand 0800 444 365 Pakistan 632 63684 15 IDD via Philippines Philippines 1 800 1 651 0117 Singapore 65 6213 1311 Taiwan
103. rd fully seated in the connectors on the server board Are all jumper settings on the server board correct Are the configuration settings defined in the BIOS Setup correct Is the operating system properly loaded Refer to the operating system documentation Are all device drivers properly installed Are all installed components and the installed operating system listed in the Intel Modular Server System MF SYS25 MFSYS35 and Intel Compute Module MFS5000SI MFS5520VI Tested Hardware and Operating System List Intel Compute Module MFS5520VI User Guide 95 Hardware Diagnostic Testing This section provides a more detailed approach to identifying and correcting a hardware problem 1 2 Turn off the compute module Connect a keyboard and video monitor to the USB and video ports located on the front of the compute module Turn on the video monitor and set the brightness and contrast controls to at least two thirds of the maximum range see the documentation supplied with your video display monitor Verify that the chassis power supplies are properly installed and connected to grounded AC outlets and the chassis power LEDs are on Turn on the compute module 5 Ifthe power LED does light but will not boot the operating system from the hard drive attempt to boot from a bootable media in either a USB floppy drive or a USB CD ROM drive Ifthe power LED does not light see Power LED Does Not Light
104. re de macropart culas en suspensi n en el aire que no sean el polvo habitual de la habitaci n Bien ventilada y alejada de fuentes de calor incluida la luz solar directa y los radiadores Alejada de fuentes de vibraci n o de golpes f sicos Aislada de campos electromagn ticos producidos por dispositivos el ctricos En zonas propensas a tormentas el ctricas se recomienda que conecte el servidor a un supresor de sobretensiones y desconecte las l neas de telecomunicaciones al m dem durante una tormenta el ctrica Provista de una toma de corriente alterna correctamente conectada a tierra Provista de espacio suficiente para acceder a los cables de la fuente de alimentaci n ya que constituyen la desconexi n principal de la alimentaci n Intel Compute Module MFS5520VI User Guide 123 Manipulaci n del equipo Reduzca el riesgo de dafios personales o en el equipo e Respete los requisitos de sanidad y seguridad laborales de su pa s cuando traslade y levante el equipo e Utilice medios mec nicos u otros que sean adecuados al trasladar o levantar el equipo Para que el peso sea menor para manipularlo con m s facilidad extraiga los componentes que sean de f cil extracci n Advertencias de alimentaci n y el ctricas Precauci n El bot n de encendido indicado con la marca del modo de reposo o stand by NO DESCONECTA completamente la alimentaci n de CA del sistema ya que el modo de reposo de 5 V sigue activo
105. rf gbar eine leitfahige Schaumstoffunterlage aber niche die Schutzh lle der Platine Ziehen Sie die Platine nicht ber eine Fl che Intel Compute Module MFS5520VI User Guide Andere Gefahren Batterieaustausch Vorsicht Wird die Batterie unsachgem ausgetauscht besteht Explosionsgefahr Verwenden Sie als Ersatz nur die vom Ger tehersteller empfohlene Batterie Beachten Sie bei der Entsorgung von Batterien die g ltigen Bestimmungen Versuchen Sie nicht eine Batterie aufzuladen Versuchen Sie nicht eine Batterie zu ffnen oder sonstwie zu besch digen K hlung und Luftstrom Vorsicht Verlegen Sie Kabel sorgf ltig entsprechend der Anleitung um St rungen des Luftstroms und K hlungsprobleme zu vermeiden Zur Gew hrleistung des ordnungsgem en K hlungs und Luftstromverhaltens darf das System nur mit angebrachten Geh useabdeckungen betrieben werden Die Inbetriebnahme des Systems ohne Abdeckung kann zur Besch digung von Systemkomponenten f hren So bringen Sie die Abdeckung wieder an e Vergewissern Sie sich zun chst da Sie keine Werkzeuge oder Teile im Geh use vergessen haben e Pr fen Sie ob Kabel Erweiterungskarten sowie weitere Komponenten ordnungsgem angebracht sind e Befestigen Sie die Abdeckungen am Geh use des Produkts wie in dessen Anleitung beschrieben Laser Peripherieger te oder Komponenten Vorsicht Beachten Sie zur Vermeidung von Strahlung und Verletzungen die folgenden Hi
106. rk If you are running the software from a diskette CD ROM or DVD ROM try a different media e Make sure the correct device drivers are installed If the problems persist contact the software vendor s customer service representative Problems with Application Software that Previously Functioned Properly Check the following e Uninstall and reinstall the software Make sure all necessary files are installed If you suspect that a transient voltage spike power outage or brown out might have occurred reload the software and try running it again Symptoms of voltage spikes include a flickering video display unexpected reboots and the compute module not responding to user commands Note Random errors in data files If you are getting random errors in your data files they may be getting corrupted by voltage spikes on your power line If you are experiencing any of the above symptoms that might indicate voltage spikes on the power line you may want to install a power conditioner between the power outlet and the compute module power cord Devices are Not Recognized within the Operating System Operating systems include a limited set of device drivers by default Ensure that you install all necessary drivers at the time you install the operating system Intel Compute Module MFS5520VI User Guide 99 100 Intel Compute Module MFS5520VI User Guide A Getting Help World Wide Web http support intel com support mothe
107. rom the Main screen press the right arrow key until the Advanced menu is selected then select Memory Configuration From the Memory Configuration screen select Memory RAS and Performance Configuration and press lt Enter gt Aptio Setup Utility Copyright C 2009 American Megatrends Inc NUMA Optimized Enabled Figure 48 Memory RAS and Performance Configuration Screen Mass Storage Controller Configuration The Mass Storage Controller Configuration screen allows you to enable or disable the SAS controller By default the SAS controller is set to Enabled This enables the compute module to access the system storage If the SAS controller is set to Disabled the compute module will not be able to access storage 66 Intel Compute Module MFS5520VI User Guide To access this screen from the Main menu press the right arrow key until the Advanced menu is selected the press the down arrow key until Mass Storage Controller Configuration is highlighted and press lt Enter gt Aptio Setup Utility Copyright C 2009 American Megatrends Inc SAS controller Enabled Figure 49 Advanced Mass Storage Controller Configuration Screen Serial Port Configuration The Serial Port Configuration screen enables the user to configure the Network Serial Console and the Debug Serial Port To configure both the Network Serial Console and the Debug Serial Port the user can modify the following settings Enable or Disable the serial po
108. rt Network Serial Console or Debug Serial Port Select the base I O address Select the interrupt request IRQ line Intel Compute Module MFS5520VI User Guide 67 To access this screen from the Main screen press the right arrow key until the Advanced menu is selected then press the down or up arrow key until Serial Port Configuration is highlighted and press lt Enter gt Aptio Setup Utility Copyright C 2009 American Megatrends Inc Network Serial Console Enabled Figure 50 Advanced Serial Port Configuration Screen USB Configuration The USB Configuration screen allows you to configure the USB controller options 68 Intel Compute Module MFS5520VI User Guide To access this screen from the Main screen press the right arrow key until the Advanced menu is selected then press the down or up arrow key until USB Configuration is highlighted and press lt Enter gt Aptio Setup Utility Copyright C 2009 American Megatrends Inc USB Controller Enabled Figure 51 Advanced USB Configuration Screen Intel Compute Module MFS5520VI User Guide 69 The following table describes the features of the Advanced USB Configuration screen Table 8 USB Configuration Details PCI Configuration Setup Item Options Description Detected USB Information only Displays the number and Devices general description of USB devices detected for the compute module USB Controller Enabled By default
109. s ESD Attention Les decharges electrostatiques ESD peuvent endommager les lecteurs de disque dur les cartes et d autres pieces Il est fortement conseill d effectuer l ensemble des proc dures decrites a un poste de travail protege contre les ESD Au cas o aucun poste de ce type ne serait disponible protegez vous contre les ESD en portant un bracelet antistatique reli la masse du ch ssis n importe quelle surface m tallique non peinte de votre serveur lorsque que vous manipulez les pieces Manipulez toujours les cartes avec pr caution Elles peuvent tre extr mement sensibles aux ESD Ne tenez les cartes que par leurs bords Apres avoir retir une carte de son emballage de protection ou du serveur placez la sur une surface reli e la terre exempte de charge statique composants orient s vers le haut Utilisez si possible un tapi de mousse conducteru mais pas l emballage de la carte Veillez ce que la carte ne glisse sur aucune surface Autres risques Remplacement de la pile Attention Il existe un risque d explosion si la pile n est pas correctement remplac e Lors du remplacement de la pile utilisez uniquement celle recommandee par le fabricant du materiel Mettez la pile au rebut en vous conformant aux reglementations locales N essayez pas de recharger une pile N essayez pas de d monter de percer ou d endommager la pile d une quelconque facon Refroidissement et ventilation Attent
110. s To do this 1 Unlock and remove the padlock from the back of the system if a padlock has been installed 2 Remove and save all screws from the covers 3 Remove the cover s Intel Compute Module MFS5520VI User Guide 133 For proper cooling and airflow always reinstall the chassis covers before turning on the system Operating the system without the covers in place can damage system parts To install the covers 1 Check first to make sure you have not left loose tools or parts inside the system 2 Check that cables add in boards and other components are properly installed 3 Attach the covers to the chassis with the screws removed earlier and tighten them firmly 4 Insert and lock the padlock to the system to prevent unauthorized access inside the system 5 Connect all external cables and the AC power cord s to the system A microprocessor and heat sink may be hot ifthe system has been running Also there may be sharp pins and edges on some board and chassis parts Contact should be made with care Consider wearing protective gloves Danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the equipment manufacturer Dispose of used batteries according to manufacturer s instructions The system is designed to operate in a typical office environment Choose a site that is LE Clean and free of airborne particles
111. s ai 1 Feature WON EN om ee E E a a EAEE E SANAR EE 3 Connector and Component Locations us 4 Configuration JumpPers lla 5 Front Panel Connectors and Indicators pp 7 Front Panel Indicators u a de nennen a E Raiti 7 Hardware Requirements ee a deere 8 PIOCESSO en ee ce ini ati 8 MEMON oe co clan 8 POWER SUPPLY ahead 9 Additional Information and Software a 10 Hardware Installations and Upgrades nes 13 Before You Begin Luse 13 Tools and Supplies Needed pp 13 Installation Guidelines essentiel nn dd 13 Removing and Installing an Intel Compute Module MFS5520V pp 13 Removing a Compute Module from the Chassis i 13 Installing a Compute Module into the Chassis pp 14 Removing or Installing the Top Cover visitan 14 Removing the Top Cover daa 14 Installing the Top GoVer unu i n oiana iaa 16 Installing or Replacing a Processor eu en ae 17 stalling a Processor ww 17 Replacing Processor sd en ds 25 Installing and Removing Memory Modules pp 33 Supp rled Memory ET 33 Memory Map and Population Rules ss 33 Inst lling DIMMS 4 se ee ee naine es titine 35 Removing IE 38 Intel Compute Module MFS5520VI User Guide vii Installing and Removing Mezzanine Card 42 Installing the Mezzanine Card naar 42 Removing a Mezzanine Card iii 46 Replacing the CMOS Battery aa eu a nt 49 BIOS Setup Utility NEEERFFEREREEEREFENFE EEE BR RE FAR DELENNPRFF EHER 53 Starting BIO
112. s System gesteckt wird sollte sich in der N he des Ger tes befinden und leicht zug nglich sein SICHERHEITSMASSNAHMEN Immer wenn Sie die Geh useabdeckung abnehmen um an das Systeminnere zu gelangen sollten Sie folgende Schritte beachten 1 Schalten Sie alle an Ihr System angeschlossenen Peripherieger te aus 2 Schalten Sie das Rechenmodul mit dem Hauptschalter aus 3 Ziehen Sie den Stromanschlu stecker Ihres Systems aus der Steckdose 4 Auf der R ckseite des Systems beschriften und ziehen Sie alle Anschlu kabel von den I O Anschl ssen oder Ports ab 5 Tragen Sie ein geerdetes Antistatik Gelenkband um elektrostatische Ladungen ESD ber blanke Metallstellen bei der Handhabung der Komponenten zu vermeiden 6 Schalten Sie das System niemals ohne ordnungsgem montiertes Geh use ein Intel Compute Module MFS5520VI User Guide 135 SICHERHEITSMASSNAHMEN Immer wenn Sie die Geh useabdeckung abnehmen um an das Systeminnere zu gelangen sollten Sie folgende Schritte beachten 1 Schalten Sie alle an Ihr System angeschlossenen Peripherieger te aus 2 Schalten Sie das System mit dem Hauptschalter aus 3 Ziehen Sie den Stromanschlu stecker Ihres Systems aus der Steckdose 4 Auf der R ckseite des Systems beschriften und ziehen Sie alle Anschlu kabel von den I O Anschl ssen oder Ports ab 5 Tragen Sie ein geerdetes Antistatik Gelenkband um elektrostatische Ladungen ESD ber blanke
113. s bordes Una vez extra da la tarjeta de su envoltorio de protecci n o del servidor col quela con el lado de los componentes hacia arriba sobre una superficie con toma de tierra y sin carga est tica Utilice una Intel Compute Module MFS5520VI User Guide 125 almohadilla de espuma conductora si dispone de ella pero nunca el envoltorio de la tarjeta No deslice la tarjeta sobre ninguna superficie Otros peligros Sustituci n de la bateria Precauci n Existe el peligro de explosi n si la bateria no se reemplaza correctamente Al reemplazar la bater a utilice s lo la bater a recomendada por el fabricante del equipo Deseche las bater as respetando la normativa local No intente recargar la bater a No intente desmontar pinchar o causar cualquier otro desperfecto a una bater a Enfriamiento y circulaci n de aire Precauci n El tendido de los cables debe realizarse cuidadosamente tal y como se le indica para reducir al m nimo los problemas de obstrucci n de la ventilaci n y de refrigeraci n Para conseguir una refrigeraci n y corriente de aire adecuadas compruebe que cuando sistema est funcionando las cubiertas de la carcasa est n instaladas Si utiliza el sistema sin las cubiertas podr a da ar sus componentes Para instalar las cubiertas Compruebe primero que no ha dejado herramientas o piezas sueltas dentro del sistema Compruebe que los cables tarjetas adicionales y otros componentes est n instal
114. sconecte el cable de alimentaci n los sistemas de telecomunicaciones las redes y los m dems conectados al mismo Advertencias el acceso al sistema Precauci n Para evitar lesiones personales o da os en la propiedad se aplican las siguientes instrucciones de seguridad siempre que se acceda al interior del producto Apague todos los dispositivos perif ricos conectados a este producto Pulse el bot n de alimentaci n para apagar el sistema Desconecte la alimentaci n de CA desenchufando los cables de alimentaci n de CA del sistema o de la toma de corriente alterna 124 Intel Compute Module MFS5520VI User Guide Desconecte todos los cables y l neas de telecomunicaci n que est n conectados al sistema Guarde todos los tornillos o elementos de fijaci n cuando retire las cubiertas de acceso Cuando termine de operar en el interior del producto vuelva a colocar los tornillos o los elementos de fijaci n originales de la cubierta de acceso No acceda al interior de la fuente de alimentaci n No hay elementos en la fuente de alimentaci n que usted pueda reparar y utilizar Devu lvala al fabricante para repararla e Apague el servidor y desconecte todos los cables de alimentaci n antes de agregar o reemplazar cualquier componente que no es de conexi n en funcionamiento e Al reemplazar una fuente de alimentaci n de conexi n en funcionamiento desenchufe el cable de alimentaci n de la fuente de alimentaci n q
115. ser Guide C Safety Information English Server Safety Information This document applies to Intel server boards Intel server chassis and installed peripherals To reduce the risk of bodily injury electrical shock fire and equipment damage read this document and observe all warnings and precautions in this guide before installing or maintaining your Intel server product In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product the product documentation takes precedence Your server should be integrated and serviced only by technically qualified persons You must adhere to the guidelines in this guide and the assembly instructions in your server manuals to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL Listing and other regulatory approvals of the product and may result in noncompliance with product regulations in the region s in which the product is sold Safety Warnings and Cautions To avoid personal injury or property damage before you begin installing the product read observe and adhere to all of the following safety instructions and information The following safety symbols may be used throughout the documentation and may be marked on the product and or the product
116. server board 42 Intel Compute Module MFS5520VI User Guide 7 Using a Phillips screwdriver remove four screws from the server board see Figure 36 AF003090 Figure 36 Removing Screws from Server Board Intel Compute Module MFS5520VI User Guide 43 8 Using a 1 4 inch nut driver install the four standoffs that shipped with the mezzanine card see Figure 37 AF003082 Figure 37 Installing Standoffs for Mezzanine Card 44 Intel Compute Module MFS5520VI User Guide 9 Position the mezzanine card above the mezzanine card connectors on the server board and align the four screw holes with the standoffs taking care to position each connector housing on the mezzanine card with the connectors on the server board see letter A in Figure 38 10 Carefully press the mezzanine card into place until it is fully seated in the connectors and resting on the standoff supports 11 Secure the mezzanine card to the standoffs with the four screws previously removed see letter B in Figure 38 AF003083 Figure 38 Installing and Securing the Mezzanine Card 12 Reinstall the top cover For instructions see Installing the Top Cover on page 16 13 Reinstall the server compute module in the chassis For instructions see Installing a Compute Module into the Chassis on page 14 Intel Compute Module MFS5520VI User Guide 45 Removing a Mezzanine Card 46 To remove a mezzanine card follo
117. solamente pilas iguales o del mismo tipo que las recomendadas por el fabricante del equipo Para deshacerse de las pilas usadas siga igualmente las instrucciones del fabricante El sistema esta disefiado para funcionar en un entorno de trabajo normal Escoja un lugar LE Limpio y libre de part culas en suspensi n salvo el polvo normal i Bien ventilado y alejado de fuentes de calor incluida la luz solar directa e Alejado de fuentes de vibraci n Aislado de campos electromagn ticos fuertes producidos por dispositivos el ctricos En regiones con frecuentes tormentas el ctricas se recomienda conectar su sistema a un eliminador de sobrevoltage y desconectar el m dem de las l neas de telecomunicaci n durante las tormentas e Provisto de una toma de tierra correctamente instalada e Provisto de espacio suficiente como para acceder a los cables de alimentaci n ya que stos hacen de medio principal de desconexi n del sistema Intel Compute Module MFS5520VI User Guide 141 Italiano Rivolgersi ad un tecnico specializzato per la riparazione dei componenti dell alimentazione di questo prodotto E possibile che il prodotto disponga di pi fonti di alimentazione Non modificare o utilizzare il cavo di alimentazione in c a fornito dal produttore se non corrisponde esattamente al tipo richiesto Ad ogni fonte di alimentazione corrisponde un cavo di alimentazione in c a separato
118. sor s Verify that the installed memory is validated for use in the compute module Verify that the installed memory has been populated according to the compute module requirements e Remove and re seat the memory e Is the keyboard functioning Test it by turning the Num Lock function on and off to see if the Num Lock light is working e Is the on board video controller enabled in the BIOS Characters are Distorted or Incorrect Check the following e Is the video monitor properly adjusted See the manufacturer s documentation for operating instructions Are the video signal and power cables connected properly Does this video monitor work correctly if plugged into a different compute module No Available Storage Check the following Intel Compute Module MFS5520VI User Guide 97 Verify in the Intel Modular Server Control GUI that virtual drive s are assigned to the compute module e Ensure drive s assigned to the compute module are installed and operating properly Make sure the installed drives are validated for use with the Intel Modular Server System MFSYS25 MFSYS35 Refer to the Intel Modular Server System MFSYS25 MFSYS35 and Intel Compute Module MFS5000SI MFS5520VI Tested Hardware and Operating System List for validation information Cannot Connect to a Compute Module e Ensure that the Ethernet switch module is properly installed the power LED is lit and the error LED is not l
119. tem Specific Help Area The Item specific Help area is located on the right side of the screen and contains help text for the highlighted Setup Item Help information may include the meaning and usage of the item allowable values effects of the options and so on Keyboard Command Bar The Keyboard Command Bar is located at the bottom right of the screen and continuously displays help for keyboard special keys and navigation keys Figure 43 Setup Layout Intel Compute Module MFS5520VI User Guide Table 4 Keyboard Commands describes the keyboard commands you can use in the BIOS Setup menus Table 4 Keyboard Commands Press Description lt F1 gt Help Pressing F1 on any menu invokes the general Help window gt The left and right arrow keys are used to move between the major menu pages The keys have no effect if a submenu or pick list is displayed Select ltem up The up arrow is used to select the previous value in a menu item s option list or a value field pick list Pressing the Enter key activates the selected item Select Item down The down arrow is used to select the next value in a menu item s option list or a value field pick list Pressing the Enter key activates the selected item F5 Change Value The minus key or the F5 function key is used to change the value of the current item to the previous value This key scrolls through the values
120. the BIOS Setup Utility without saving changes A confirmation prompt will be displayed before exiting Setup if any Setup values were modified The compute module will not be rebooted The Esc key can also be used Save Changes Saves changes without exiting the BIOS Setup Utility Saved changes may require the compute module to be rebooted before taking effect Discard Changes Discards all changes made since the last save change operation was performed without exiting the BIOS Setup Utility The lt Esc gt key can also be used Load Default Values If Load Default Values is selected the factory default settings noted in bold in the tables in this chapter are applied The lt F9 gt key can also be used Save as User Default Values Saves current BIOS Setup Utility values as a custom set of user defined default BIOS values Note Clearing CMOS or NVRAM will cause the user default values to be reset to the factory default values Load User Default Values If Load User Default Values is selected the BIOS settings are restored to a previously saved user defined set of default values Intel Compute Module MFS5520VI User Guide 87 Upgrading the BIOS The Intel Compute Module BIOS and firmware is updated when the Intel Modular Server System MFSYS25 MFSYS35 Unified Firmware Update UFU is installed The Intel Modular Server System UFU updates all system firmware When an Intel Compute Module is inserted i
121. the USB Controller is enabled When Disabled enabled all on board USB controllers are turned Bee on and accessible by the OS If disabled all on board USB controllers are turned off and inaccessible by the OS If disabled the remaining configuration options on this screen are grayed out Legacy USB Enabled USB device boot support and PS 2 emulation for Support USB keyboard and USB mouse devices Disabled A If auto is selected Legacy USB support is uto enabled if a USB device is attached Port 60 64 Enabled I O port 60h 64h emulation support uulalon Disabled NOTE This may be needed for legacy USB keyboard support when using an OS that is USB unaware Make USB Enabled Exclude USB in Boot Table Devices Non Disabled If enabled this will remove all USB Mass Storage Bootable devices as Boot options If disabled this allows all USB Mass Storage devices as Boot options Device Reset 10 sec USB Mass Storage device start unit command time out time out 20 sec 30 Setting to a larger value provides more time for a SES mass storage device to be ready if needed 40 sec USB 2 0 Enabled When enabled on board USB ports are enabled controller Disabled to support USB 2 0 mode Contact your OS vendor regarding OS support of this feature The PCI Configuration Screen allows you to configure the memory usage and on board NIC controllers 70 Intel Compute Module MFS5520VI User Guide To access this screen from t
122. tion Jumper Name Pins What happens at reset J9B9 BIOS 1 2 These pins should have a jumper in place for normal operation Recover Default 2 3 If these pins are jumpered the compute module boots from the emergency BIOS image These pins should not be jumpered for normal operation J9A3 Password 1 2 These pins should have a jumper in place for normal operation Clear Default 2 3 If these pins are jumpered administrator and user passwords are cleared immediately These pins should not be jumpered for normal operation J9A4 CMOS 1 2 These pins should have a jumper in place for normal operation Clear Default 2 3 If these pins are jumpered the CMOS settings are cleared immediately These pins should not be jumpered for normal operation To clear the CMOS you must only momentarily move the jumper to position 2 3 You must then move the jumper back to the default position 1 2 and reinstall the compute module into the chassis J9A5 BMC Force 1 2 BMC Firmware Force Update Mode Disabled Default Update 2 3 BMC Firmware Force Update Mode Enabled Intel Compute Module MFS5520VI User Guide Front Panel Connectors and Indicators CIO 2 E GO AA vo AF003079 A USB Ports 0 and 1 B USB2 Ports 2 and 3 C Video Connector D 1 0 1 and I O 2 Activity LEDs E NIC1 and NIC
123. tres approbations r glementaires du produit et le produit peut ne pas tre conforme aux autres lois et r glementations locales applicables au produit S curit avertissements et mises en garde 118 Pour viter de vous blesser ou d endommager votre quipement lisez et respectez toutes les informations et consignes de s curit avant de commencer l installation du produit Les symboles de s curit suivants peuvent tre utilis s tout au long de cette documentation et peuvent figurer sur le produit ou sur son emballage Indique la pr sence d un risque pouvant entra ner des blessures physiques ATTENTION mineures ou endommager l g rement le mat riel si la mise en garde n est pas prise en compte AVERTISSEMENT Indique la pr sence d un risque pouvant entra ner des blessures corporelles graves si l avertissement n est pas pris en compte Indique un risque potentiel si les informations signal es ne sont pas prises en compte Indique des risques d lectrocution pouvant entra ner des blessures corporelles graves ou mortelles si les consignes de s curit ne sont pas respect es Signale des composants ou des surfaces soumis des temp ratures lev es Indique de ne pas toucher aux pales de ventilateur car cela peut entra ner des blessures Sa Indique de d brancher tous les cordons d alimentation secteur pour d connecter l alimentation 31 OE gt Veuillez r ut
124. tres attaches de c t lorsque vous retirez les panneaux d acc s Une fois que vous avez termin d acc der l int rieur du produit refixez le panneau d acces avec les vis ou attaches d origine e N essayez pas d acceder l int rieur du bloc d alimentation Il ne contient aucune pi ce r parable Renvoyez le au fabricant en cas de probl me e Mettez le serveur hors tension et d branchez tous les cordons d alimentation avant d ajouter ou de remplacer tout composant non connectable chaud e Lorsque vous remplacez le bloc d alimentation chaud d branchez le cordon du bloc d alimentation en cours de remplacement avant de retirer le bloc du serveur Intel Compute Module MFS5520VI User Guide Attention Si le serveur a t utilise les processeurs et dissipateurs de chaleur install s peuvent tre chauds moins que vous n ajoutiez ou ne retiriez un composant connectable chaud laissez le systeme refroidir avant d ouvrir les panneaux Pour viter tout risque d entrer en contact avec un composant chaud lors d une installation chaud prenez toutes les pr cautions n cessaires lorsque vous retirez ou installez des composants connectables chaud Attention Pour viter de vous blesser ne touchez pas les pales de ventilateur en mouvement Si votre systeme est fourni avec une protection sur le ventilateur ne mettez pas le systeme en route sans la protection en place Decharges lectrostatique
125. tructions English The power supply in this product contains no user serviceable parts Refer servicing only to qualified personnel Do not attempt to modify or use the supplied AC power cord if it is not the exact type required A product with more than one power supply will have a separate AC power cord for each supply The power button on the compute module does not turn off system AC power To remove AC power from the system you must unplug each AC power cord from the wall outlet or power supply The power cord s is considered the disconnect device to the main AC power The socket outlet that the system plugs into shall be installed near the equipment and shall be easily accessible SAFETY STEPS Whenever you remove the chassis covers to access the inside of the system follow these steps 1 Turn off all peripheral devices connected to the system 2 Turn off each compute module by pressing the power button 3 Unplug all AC power cords from the system or from wall outlets 4 Label and disconnect all cables connected to I O connectors or ports on the back of the system 5 Provide some electrostatic discharge ESD protection by wearing an antistatic wrist strap attached to chassis ground of the system any unpainted metal surface when handling components 6 Do not operate the system with the chassis covers removed After you have completed the six SAFETY steps above you can remove the system cover
126. ue va a reemplazar antes de extraerla del servidor Precauci n Si el servidor se ha estado ejecutando los procesadores y disipadores de calor estar n recalentados A no ser que est instalando o extrayendo un componente de conexi n en funcionamiento deje que el sistema se enfr e antes de abrir las cubiertas Para que no llegue a tocar los componentes que est n calientes cuando est realizando una instalaci n de conexi n en funcionamiento tenga cuidado al extraer o instalar los componentes de conexi n en funcionamiento Precauci n Para evitar posibles da os no toque las aspas en movimiento de los ventiladores Si el sistema se le ha suministrado con una protecci n para el ventilador aseg rese de que cuando est funcionando el sistema la protecci n est en su sitio Descarga electrost tica ESD Precauci n Las descargas electrost ticas pueden da ar las unidades de disco las tarjetas y otros componentes Recomendamos que realice todos los procedimientos en una estaci n de trabajo protegida contra descargas electrost ticas En caso de que no haya una disponible prot jase de alguna forma contra las descargas llevando un brazalete antiest tico conectado a la toma de tierra de la carcasa cualquier superficie de metal que no est pintada del servidor cuando manipule las piezas Manipule siempre las tarjetas con el m ximo cuidado Pueden ser sumamente sensibles a las descargas electrost ticas Suj telas s lo por lo
127. ure 23 Figure 24 Figure 25 Figure 26 Figure 27 Figure 28 Figure 29 Figure 30 Figure 31 Figure 32 Figure 33 Figure 34 Figure 35 Figure 36 Figure 37 Intel Compute Module MFS5520V non coran conocia 1 Semel Boll em A NE EE eee eter 2 Component and Connector LocationNnS i 4 Configuration Jumper Locations nt hage 5 Front Panel Connectors and IndicatorS 7 Removing Top COV GY nee 15 Installing TOO OV sse ne eg 16 Removing Processor Air Duct scia aa 18 AP nnn 19 Lifting the Processor Socket Lever nu 20 Opening the Load Plate nennen 20 Removing the Protective Socket Cover Nt 21 Removing the Processor Protective COVver 21 Installing the Processor ansehen en nee 22 Closing the Load Plate aan ee 22 Installing the Aegisinie scri 23 Reinstalling Processor Ar DUC i 24 Removing Processor Air Duct nn 25 Removing the HeatsinK a sen an 26 Lifting Processor Socket Handle er 27 Opening the Load Plate u en aa 27 Removing P don once 28 Removing Protective Shipping Cover i 29 Orienting and Installing Processor issues 29 Closing the Load Plate and Socket Lever sssssenssssrrreeesrreseeressrrrnnerrnnnrrnnnnesene 30 Reinstalling FE oss nee ee 31 Reinstalling Processor Air DUCt non nnncnccnrnnnnnns 32 DIMM Nomenclature svenn 33 DIMM S Order Ae A 35 Removing Processor Ar Dublin 36 Installing DIMMS ee 37 Reinstalling Processor Ar Dubai 38
128. ure 25 Intel Compute Module MFS5520VI User Guide 29 30 Caution Caution Note Note AF002840 Figure 25 Closing the Load Plate and Socket Lever Installing the Heatsink Improper installation can damage the heatsink Pay close attention to the steps and perform each step exactly as indicated to avoid damage The heatsink has Thermal Interface Material TIM located on the bottom of it Use caution when you unpack the heatsink so you do not damage the TIM New unused heatsinks have adequate TIM on the bottom If you are reusing a heatsink from replacing a processor make sure there is adequate TIM present on the heatsink to support processor cooling 17 18 Remove the protective film on the TIM if present Orient the heatsink over the processor as shown in Figure 26 The heatsink fins must be positioned as shown to provide correct airflow through the system Airflow goes from front to back of the compute module Figure 26 illustrates the heatsink orientation for CPU 1 The heatsink over CPU 2 should be oriented in a reverse direction so as to provide correct airflow through the compute module 19 20 Set the heatsink over the processor lining up the four captive screws with the four posts surrounding the processor Loosely screw in the captive screws on the heatsink corners in a diagonal manner according to the numbers shown in Figure 26 as follows a Starting with the screw at location 1 eng
129. ure 59 Boot Manager Screen 84 Intel Compute Module MFS5520VI User Guide Error Manager The Error Manager screen displays any errors encountered during POST To access this screen from the Main screen press the right arrow key until the Error Manager menu option is selected Aptio Setup Utility Copyright C 2009 American Megatrends Inc Figure 60 Error Manager Screen Intel Compute Module MFS5520VI User Guide 85 Exit The Exit screen provides the user with the ability to save or discard changes before exiting the utility to save changes as a user defined default configuration and to load either the factory or user defined default settings To access this screen from the Main screen press the right arrow until the Exit option is selected Aptio Setup Utility Copyright C 2009 American Megatrends Inc Save Changes and Exit Figure 61 Exit Screen The following table describes the options available on the Exit screen Table 14 Exit Screen Details Setup Item Description Save Changes and Exit If any of the setup fields were modified a confirmation prompt will be displayed before the changes are saved After saving changes and exiting the BIOS Setup Utility the compute module will be rebooted if required The lt F10 gt key can also be used 86 Intel Compute Module MFS5520VI User Guide Table 14 Exit Screen Details Setup Item Description Discard Changes and Exit Exit
130. ver Management System Information Screen 81 Boot Options Screen 82 Boot Manager Screen aan eu 84 Error Manager Screen ee nee 85 SES a A EAE REE AE RE RRE 86 Password Clear Jumper esse ne 90 CMOS Clear Jumper ausm air 92 Intel Compute Module MFS5520VI User Guide List of Tables Table 1 Compute Module Features ss 3 Table 2 Configuration Jumper Description ssssssssssrneeeerersstrrsssrrrnertrnttrtrtrnsstrnnsetennnrnnn nenne 6 Table 3 Diagnostic LED Informatiom ss 7 Table 4 Keyboard Commands a ah 55 Table 5 Main Screen Details iii 59 Table 6 Advanced Processor Configuration Details 62 Table 7 Advanced Memory Configuration Screen Details 65 Table 8 USB Configuration DetailS eee 70 Table 9 Advanced PCI Configuration Details ennnnneeessneeeenneeesrtrrnerrrnrrrrnnnrsrnrrnserrrnserrnne 72 Table 10 Security Screen Details ann a enmasnnnat 75 Table 11 Server Management Screen Details pp 77 Table 12 Server Management Console Redirection Details 80 14618 13 Boot Options Deals a ee en 83 Table 14 Exit Screen Details issus 86 Intel Compute Module MFS5520VI User Guide xiii xiv Intel Compute Module MFS5520VI User Guide 1 Compute Module Features This chapter briefly describes the main features of the Intel Compute Module MFS5520VI as well as provides illustrations showing the location of important components and connections on the compute module The Intel Com
131. w these steps 1 Observe the safety and ESD information at the beginning of this manual and in the appendices 2 If the compute module is installed in a chassis remove it For instructions see Removing a Compute Module from the Chassis on page 13 Remove the top cover For instructions see Removing the Top Cover on page 14 4 Locate the mezzanine card Nn Using a Phillips screwdriver remove the four screws securing the mezzanine card to the standoffs see Figure 39 Non AF003091 Figure 39 Removing Screws from Mezzanine Card Intel Compute Module MFS5520VI User Guide 6 Holding the mezzanine card by its edges gently lift it from the connectors and store it in an anti static package see Figure 40 AF003092 Figure 40 Removing Mezzanine Card Intel Compute Module MFS5520VI User Guide 47 7 Using a 1 4 inch nut driver remove the standoffs see Figure 41 AF003093 Figure 41 Removing Standoffs 8 Using a Phillips screwdriver secure the four screws that were previously removed into the holes vacated by the standoffs 9 Reinstall the top cover For instructions see Installing the Top Cover on page 16 10 Reinstall the server compute module in the chassis For instructions see Installing a Compute Module into the Chassis on page 14 48 Intel Compute Module MFS5520VI User Guide Replacing the CMOS Battery Warning Advarsel Advarsel Varn
132. ward to the closed position until the retention latch fully engages see letter B in Figure 7 AF003089 Figure 7 Installing Top Cover 16 Intel Compute Module MFS5520VI User Guide Installing or Replacing a Processor Caution Processor must be appropriate You may damage the compute module if you install an inappropriate processor Caution ESD and handling processors Reduce the risk of electrostatic discharge ESD damage to the processor by doing the following 1 Touch the metal chassis before touching the processor or compute module Keep part of your body in contact with the metal chassis to dissipate the static charge while handling the processor 2 Avoid moving around unnecessarily Caution Protective socket cover needs to be removed for proper cooling of the processor failure to remove the cover could result in damage to the compute module Installing a Processor To install a processor follow these steps 1 Observe the safety and ESD information at the beginning of this manual and in the appendices Removing Components 2 If the compute module is installed in a chassis remove it For instructions see Removing a Compute Module from the Chassis on page 13 3 Remove the top cover For instructions see Removing the Top Cover on page 14 Intel Compute Module MFS5520VI User Guide 17 4 Remove the processor air duct see Figure 8 AF003080 Figure 8 Removing Processor Air Duct
133. ware Update process is started from within the Intel Modular Server Control UI Refer to the Intel Modular Server System MFSYS25 MFSYS35 User Guide for information on how to access and use the Intel Modular Server Control UI 88 Intel Compute Module MFS5520VI User Guide Caution Do not power down the system during the BIOS update process Note You may encounter a CMOS Checksum error or other problem after reboot If this happens shut down the compute module and boot it again CMOS checksum errors require that you enter Setup check your settings save your settings and exit Setup Clearing the Password If the user or administrator password s is lost or forgotten moving the password clear jumper into the clear position clears both passwords You must restore the password clear jumper to its original position before you can set a new password s The password clear jumper is located on jumper block J9A3 1 Power down the compute module 2 Remove the compute module from the Intel Modular Server System 3 Remove the compute module cover For instructions refer to Section Removing the Top Cover on page 14 4 Move the jumper J9A3 from the default operating position covering pins 1 and 2 to the password clear position covering pins 2 and 3 Intel Compute Module MFS5520VI User Guide 89 90
Download Pdf Manuals
Related Search
Related Contents
argomenti per i Capitoli Zug Télécharger - Economie Politique 2.2 SG 03.3 - SG 05.3 AUMA NORM Instrucciones de servicio - NovAtel Inc. KPN Samsung Ch@t 335 2.4" 100g Black 60-007型 60-008型 取扱説明書 保証書付 ガス衣類乾燥機 乾太くん PDF file - LFCS - University of Edinburgh VarioCooking Center® Samsung UD46A User Manual Samsung M192DNR Инструкция по использованию Copyright © All rights reserved.