Home

TM-LCD FLAT-PANEL TECHMOUNT OWNERS MANUAL

image

Contents

1. SCREWS NOTE For small screens ensure you have turned the bolts into the screen mounting points gt 5 times For large screens ensure you have turned the bolts at least 10 times HANG FLAT PANEL 6 TM LCD_manual_en SPECIFICATIONS INDIVIDUAL BRACKET DIMENSIONS 56 x 36 x 10mm WEIGHT 310g SAFE WORKING LOAD 4 x 12 5kg 50kg COLOUR Aluminium WARRANTY This product comes with a 2 year return to base warranty effective from the date of purchase This warranty applies only to the original purchaser and is not transferable For the avoidance of doubt this will be taken from the information held by the appointed national distributor at the point of sale The liability of the manufacturer and its appointed service company is limited to the cost of repair and or replacement of the faulty unit under warranty except for death or injury EU85 374 EEC This warranty protects you against the following e Faulty welds resulting in the product not safely performing its task within the recommended SWL safe working load e Poor finishing resulting in the product not being able to be assembled e External corrosion if identified within 24 hours of purchase Some parts of the product are not powder coated or painted so light corrosion may develop over time This is normal and does not adversely affect the load bearing capability of the product therefore it is not covered in this warranty If you find you do have a problem with this produc
2. Wo da E 7 F 491 ts Be 17 ae t DS Ny gt A D 4 M ZE Ep V TM LCD FLAT PANEL TECHMOUNT OWNERS MANUAL TM LCD_manual_en www visionaudiovisual com techmount tm lcd 2 TM LCD_manual_en DECLARATION OF CONFORMITY Where applicable Vision products are certified and comply with all known local regulations to a CB Certification standard Vision commits to ensure all products are fully compliant with all applicable certification standards for sale in the EU and other participating countries The product described in this owner manual is in compliance with RoHS EU directive 2002 95 EC and WEEE EU directive 2002 96 EC standards This product should be returned to the place of purchase at the end of its useful life for recycling WARNINGS During installation take care to adhere to workplace health and safety laws e Attach the bracket to a rated load bearing structure Ensure the correct fixtures are used to attach the Techmount to the wall or A ceiling The fixtures provided may not be suitable for your application e Do not cut or drill any parts above head height This should all be done using the correct safety equipment at floor level e Avoid overstretching which might result in the ladder tipping over e SWL safe working load 4 x 12 5kg 50kg e Ensure it is installed in an appropriate place for example not obstructing an emergency exit e Check stab
3. ility after installation e Installation must be done by a specialist audio visual installer e Allow 500mm x 500mm space around the bracket e Avoid installing in a moist environment or in direct sunshine or near corrosive gas or liquid e Routing of cables through the bracket must comply with local regulations ENSURE POWER CABLE IS NOT TWISTED SQUEEZED OR SHEARED All products are designed and imported into the EU by Vision who is wholly owned by Azlan Logistics Ltd Registered in England Nr 04625566 at Lion House 4 Pioneer Business Park Clifton Moor York YO30 4GH WEEE Registration GD0046SY WKoHs 2002 95 DECLARATION OF ORIGIN All Vision products are made in the People s Republic of China PRC 3 TM LCD_manual_en CONTENTS 4 x Wall Bracket Zamak3 Painted Silver 4 x M4x12 Finger Bolts Q235 Nickle plated strength grade 4 8 4 x ST8x50 Screws Strength grade 4 8 Zinc plating 4 x M8 square washers SPCC 1 5mm Zinc plating 4 x RT expansion tube 6 5x45 HDPE 4 x ST4x25 Cross recessed Pan head Self tapping Screws Strength grade 4 8 Nickle plated 4 x M4 square washers SPCC 1 5mm Zinc plating 4 x RT expansive tube 4x30 HDPE 1 x Large Paper Template 1 x Small Paper Template 1 x Spirit Level with plastic clip Optional Additional Bolt Kit available separately 4 x M5x12 Finger Bolts Q235 Nickle plated 4 x M6x14 Finger Bolts Q235 Nickle plated 4 x M8x16 Finger Bol
4. t you should contact the AV reseller you purchased this product from The original purchaser is responsible for shipment of the product to the manufacturer s appointed service centre for repair We will endeavour to return repaired units within 5 working days however this may not always be possible in which case it will be returned as soon as practically possible This warranty does not protect this product against faults caused by abuse misuse or incorrect installation which might be caused by ignoring the guidelines set out in this manual If failure is not covered by this warranty the owner will be given the option to pay for labour and parts to repair the unit at the service company s standard rate LEGAL DISCLAIMER Because we are committed to improving our products the details above may change without prior warning This User Manual is published without warranty and any improvements or changes to the User Manual necessitated by typographical errors inaccuracies of current information or improvements to programs and or equipment may be made at any time and without notice Such changes will be incorporated into new editions of the User Manual 7 TM LCD_manual_en
5. ts Q235 Nickle plated 4 TM LCD_manual_en INSTALLATION 1 IDENTIFY PATTERN USED Vesa is a standard mounting hole layout which most flat panels use When mounting holes are 100mm x 100mm apart this is called VESA 100 2 MARK TEMPLATE Do this step if the flat panel does not use a Vesa pattern Lay flat panel face down Put paper template on screen and mark holes on template f PAN gt X N eS k 3 3 STICK TEMPLATE TO WALL Use a spirit level as you fix the template to the wall Low tack stickers included avoid paint damage NOTE All four brackets need to be positioned fixed to load bearing structures If this is not possible wood can be used to span studs 4 ATTACH BRACKETS TO THE WALL using appropriate fixtures Ensure the correct fixtures are used to attach the Techmount to the wall or ceiling The fixtures provided may not be suitable for your application The diagram shows ST8x50 screws being used which are appropriate for attaching gt 10kg flat panels to masonry To install lt 10kg flat panels to masonry use the ST4x25 screws included 1 ST8x50 Screw 2 M8 Square Washer 3 Wall Bracket 4 RT expansion tube 6 5x45 5 TM LCD_manual_en REMOVE TEMPLATE ATTACH FINGER SCREWS TO FLAT PANEL Fit finger screws to mounting points on rear of panel Turn until finger tight If the flat panel requires a larger finger screws M5 6 8 screws are sold separately P N TM LCD

Download Pdf Manuals

image

Related Search

Related Contents

Northern Industrial Tools 9560CV User's Manual  PDR-W839 - Pioneer Europe - Service and Parts Supply website  User Manual - Geringhoff  Fios Rígidos para Fixação de Fragmentos  Pinzas de perfiles, tubos, bloques, rieles GP-PL-PR  mode d`emploi pour accéder aux formations en ligne - CClin Sud-Est  Hotpoint FZ-91P User's Manual      AMX TX-MLCD User's Manual  

Copyright © All rights reserved.
Failed to retrieve file