Home

USER MANUAL - Camboard Electronics

image

Contents

1. Get front panel locking state LOCK FP LOCK FP LOCK MODE Parameter Description LOCK MODE Front panel locking state 0 or off to unlock front panel buttons 1 or on to lock front panel buttons Switch to protocol 2000 P2000 P2000 OK Protocol 2000 has a command to switch back to ASCII protocol like Protocol 3000 9 3 6 Machine Information Commands Syntax Response Read in out count INFO IO INFO IO IN NPUTS COUN OUT OUTPUTS COUN Read max preset count INFO PRST INFO PRST VID PRESET VIDEO COUNT Reset to factory default FACTORY FACTORY RESUL configuration zv 88F ame www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 9 3 7 Identification Commands Command Response Protocol handshaking CR OK CRLF Read device model MODEL MACHINE MODEL Read device serial number 7 SN SERIAL NUMBER Read device firmware version VERSION VERSION MAJOR MINOR BUILD REVISION Set machine name NAME MACHINE_NAME RESULT MACHINE NAME Reset machine name to factory NAME RST NAME RST VACHINE FACTORY NAME default RESULT Note The machine name is not the same as the model name The machine name is used to identify a specific machin
2. 5 Change the parameters as required and then click Save www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 7 Technical Specifications OPERATING TEMPERATURE 0 to 40 C 32 to 104 F WEIGHT 2 6kg 5 7lbs approx ACCESSORIES Power cord rack ears and IR remote control transmitter OPTIONS External remote IR receiver cable SFP OPTIONS SFP IN OUT 2KM SFP Fiber Optic Module SM 2km 3G HD SDI Tx Rx SFP IN OUT 30KM SFP Fiber Optic Module SM 30km 3G HD SDI Tx Rx SFP IN OUT 40KM SFP Fiber Optic Module SM 40km 3G HD SDI Tx Rx Video SFP supports pathological patterns Specifications are subject to change without notice at http www kramerelectronics com www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 88FO Technical Specific im Vertrieb von CAMBOARD Electronics 8 Default Communication Parameters Protocol 2000 Protocol 3000 Default Baud Rate to Input 1 Switching Protocol P2000 P3000 Front Panel Ethernet IP Address Subnet Mask 0x01 0x81 0x81 0x81 0x38 0x80 0x83 0x81 Press and hold Output 1 and Output 3 simultaneously 192 168 1 39 255 255 255 0 Baud Rate Data Bits Stop Bits Parity Command Format Example Output 1 to Input 1 P3000 P2000 Command Front Panel TCP Port UDP Port 115 200 ASCII HAV 1 gt 1 lt CR gt P2000 lt CR gt Press
3. Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 5 7 Controlling Using the Ethernet Port You can control the VS 88FO over the RS 232 RS 485 port or the Ethernet using the Kramer K Router application If you are controlling a standalone unit using RS 232 or the Ethernet configure the unit as master MACH 1 see Section 5 2 1 5 8 Using the Ethernet Reset Button To reset Ethernet parameters to the factory defaults 1 Turn the power switch OFF then while pressing the FACTORY RESET button turn the power switch ON 2 The unit powers up and loads its memory with the factory default definitions 3 The unit also erases all stored presets returns to the default Protocol 3000 and indicates F rst on the 7 segment display VS 88FO Cc cting the VS 88FO ilk 9 i www camboard de Tel 07131 911201ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 6 6 1 Operating the VS 88FO You can operate your VS 88FO using e The front panel buttons e RS 232 RS 485 serial commands transmitted by a touch screen system PC or other serial controller e The RC IR3 infrared remote control transmitter Operating the VS 88FO from the Front Panel Use the front panel buttons to perform the following operations Power On Display When the VS 88FO is powered on the display briefly shows the 4 digit firmware version number and the genlock timing setting Then the display changes to its normal
4. TCP IP Properties x General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 192 168 1 2 Subnet mask 255 255 255 0 Default gateway Use the following DNS server addresses Preferred DNS server Alternate DNS server Advanced em Figure 7 Internet Protocol TCP IP Properties Window E VS 88FO Connecting the VS 88FO www camboard de Tel 07131 911201ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 5 5 2 Connecting the Ethernet Port to a Network Hub Straight Through Cable You can connect the Ethernet port of the VS 88FO to the Ethernet port on a network hub or network router using a straight through cable with RJ 45 connectors 5 6 Configuring the Ethernet Port Initially To initially configure the Ethernet port download the K UPLOAD Ethernet configuration software from the Kramer Web site at http www kramerelectronics com Extract the file to a folder and create a shortcut on your desktop to the file To configure the Ethernet port 1 Double click the desktop icon The K UPLOAD screen appears KK K UPLOAD File Help Device Properties Upload File Connection Not connected Select File OEM File Typ
5. HD SDI Fiber Optic Matrix Switcher VS 88F0 Feature Function The yellow LED illuminates when receiving signals from the infrared remote control transmitter POWER LED Illuminates when the unit is ON ALL Button Pressing ALL followed by an INPUT button connects that input to all outputs OFF Button Pressing OFF OUT disconnects that output from the inputs pressing OFF ALL disconnects all the outputs IN SELECT Buttons Select the input to switch to the output long presses on buttons N 1 to IN 5 change the genlock timing see Section 5 4 OUT SELECT Buttons Select the output to which the input is switched pressing OUT 1 OUT 2 selects Protocol 2000 pressing OUT 1 OUT 3 selects Protocol 3000 STO STORE Button Pressing STO followed by an N OUT button stores the current setting RCL RECALL Button Pressing the RCL button and the corresponding N OUT key under the selected button recalls a setup from the non volatile memory LOCK Button A long press toggles activation inactivation of the front panel buttons TAKE Button Pressing TAKE toggles the mode between the CONFIRM mode and the AT ONCE mode user confirmation per action is unnecessary INPUT STATUS LEDs Illuminate green when an active input is detected 7 segment Display Displays the selected input switched to the output marked above each input www camboard de Tel 07131 911201 ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics FH OPAO OU
6. and hold Output 1 and Output 2 simultaneously 5000 or 10001 or 50000 50000 www camboard de Tel 07131 911201ce info cambo Fax 07131 911203 ult Communication Par e ird de im Vertrieb von CAMBOARD Electronics 9 9 1 Kramer Protocol 3000 The VS 88FO can be operated using serial commands from a PC remote controller or touch screen The unit communicates using the default Kramer Protocol 3000 but can also use Kramer Protocol 2000 This section describes e How to switch between Protocol 3000 and Protocol 2000 see Section 9 1 e Kramer Protocol 3000 syntax see Section 9 2 e Kramer Protocol 3000 commands see Section 9 3 Switching Protocols Protocols can be switched either from the front panel buttons or by transmitting protocol commands To switch protocols using the front panel buttons e To choose Protocol 2000 press OUT 1 and OUT 2 at the same time e To choose the Protocol 3000 press OUT 1 and OUT 3 at the same time To switch protocols using protocol commands e To switch from Protocol 3000 to Protocol 2000 send the following command P2000 lt CR gt e To switch from Protocol 2000 to Protocol 3000 send the following command 0x38 0x80 0x83 0x81 Note If you are using Kramer s Windows based control software it operates only with Protocol 2000 If the VS 88FO is set to Protocol 3000 it automatically switches to Protocol 2000 Download the latest software from our Web site at http ww
7. any device equipped with an RS 485 port for example a PC For successful communication you must set the RS 485 machine number and bus termination www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics To connect a device with a RS 485 port to the VS 88FO e On the PC connect the A pin on the RS 485 port to the A pin on the RS 485 port on the rear panel of the VS 88FO e Onthe PC connect the B pin on the RS 485 port to the B pin on the RS 485 port on the rear panel of the VS 88FO e Onthe PC connect the G pin on the RS 485 port to the G pin on the RS 485 port on the rear panel of the VS 88FO 5 3 1 Setting the Machine Number Switches To set the MACH DIP switches as shown in Section 5 2 2 e For a master machine assign MACH 1 with the address 0 0000 or 1 0001 set in the DIP switches e For the slave units assign a unique MACH from 2 to 15 for each VS 88FO slave The units do not have to be sequentially numbered but they must have unique addresses 5 3 2 Setting the Line Termination To ensure correct operation the RS 485 line must be terminated at both ends The master unit may be located at any part of the line but when it is at the end of the line the termination switch must be set ON To set line termination as shown in Figure 5 e For the VS 88FO units located at the ends of the RS 485 line set the RS 485 TERM DIP switch ON e
8. connecting the Ethernet port configure your PC as follows 1 Right click the My Network Places icon on your desktop 2 Select Properties 3 Right click Local Area Connection Properties 4 Select Properties The Local Area Connection Properties window appears YE Tel 07131 911201ce info camboard de Fax 07131 911203 8FC www camboard de im Vertrieb von CAMBOARD Electronics 5 Select the Internet Protocol TCP IP and click the Properties Button see Figure 6 Local Area Connection Properties General Advanced Connect using E9 Intel R PRO 100 VE Network Conne Configure This connection uses the following items M E Client for Microsoft Networks al File and Printer Sharing for Microsoft Networks vi E QoS Packet Scheduler 4 Internet Protocol TCP IP Description Transmission Control Protocal Internet Protocol The default wide area network protocal that provides communication across diverse interconnected networks Show icon in notification area when connected Notify me when this connection has limited or no connectivity Figure 6 Local Area Connection Properties Window 6 Select Use the following IP Address and fill in the details as shown in Figure 7 You can use any IP address in the range 192 168 1 1 to 192 168 1 255 excluding 192 168 1 39 that is provided by your IT department 7 Click OK Internet Protocol
9. have a unique machine number Mach DIP SWITCH 1 2 1 Single or OFF master unit ON OFF o 8FO Connecting the V www camboard de Tel 07131 911201ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics After changing the address reset the device by turning it OFF and ON 5 2 2 Setting the DIP Switches When controlling a unit using the RS 232 or RS 485 ports set the DIP switches on the rear of the unit accordingly Figure 5 defines the DIP switches The default address is 0 All DIP switches are OFF Mach RE os o EL EL REI RII Yo O 1234 B E on TF ON Figure 5 DIP Switch Settings DIPS Function Description RS 485 TERM RS 485 line OFF for no RS 485 line termination termination ON for RS 485 1200 line termination PROG Firmware update Set ON only to update device firmware Sets the MACHINE see Section 5 2 1 MACH 1 2 3 4 Self Address The RS 485 TERM DIP switch is used only when the RS 485 port is connected see Section 5 3 The first and last units on the RS 485 line for example the controller and the last VS 88FO must be terminated The units in between must not be terminated Set the PROG DIP switch ON only while updating the unit firmware otherwise the switch must be OFF 5 3 Connecting a PC or Controller to the RS 485 Port You can operate the VS 88FO over the RS 485 port from a distance of up to 1200 meters 3900ft using
10. the reply would be the decimal value of the INPUT and OUTPUT the INPUT representing the number in front of the decimal point and the OUTPUT representing the number after it For example for version 3 5 the reply to the request to send the version number would be HEX codes 7D 83 85 81 i e 12844 3s for 2 byte 128400 Sec for 3 byte If the OUTPUT is set as 1 then the ASCII coding of the lettering following the machine s name is sent For example for the VS 7588YC the reply to the request to send the first suffix would be HEX codes 7D D9 C3 81 i e 128 ASCII for Y 128dec ASCII for C NOTE 14 The number of inputs and outputs refers to the specific machine which is being addressed not to the system For example if six 16X16 matrices are configured to make a 48X32 system 48 inputs 32 outputs the reply to the HEX code 3E 82 81 82 i e request the number of outputs would be HEX codes 7E 82 90 82 i e 16 outputs NOTE 15 When the OVR bit 4 byte is set then the video commands have universal meaning For example instruction 1 SWITCH VIDEO will cause all units including data etc to switch Similarly if a machine is in FOLLOW mode it will perform any video instruction NOTE 16 The reply to the REQUEST WHETHER PANEL IS LOCKED is as in NOTE 4 above except that here the OUTPUT is assigned with the value 0 if the panel is unlocked or 1 if it is locked NOTE 19 After t
11. 2 Getting Started 2 2 1 Achieving the Best Performance 2 2 2 Safety Instructions 2 2 3 Recycling Kramer Products 3 3 Overview 4 3 1 Defining the SFP 5 3 2 Defining the VS 88FO 8x8 3G HD SDI Fiber Optic Matrix Switcher 5 4 Installing in a Rack 8 5 Connecting the VS 88FO 9 5 1 Installing the SFP Modules 11 5 2 Connecting the RS 232 Port 12 5 3 Connecting a PC or Controller to the RS 485 Port 13 5 4 Switching Genlocked Video Signals 14 5 5 Connecting the Ethernet Port 15 5 6 Configuring the Ethernet Port Initially 17 5 7 Controlling Using the Ethernet Port 19 5 8 Using the Ethernet Reset Button 19 6 Operating the VS 88FO 20 6 1 Operating the VS 88FO from the Front Panel 20 6 2 Using Serial Commands 23 6 3 Using the Infrared Remote Controller 23 6 4 Upgrading the Firmware 24 6 5 Changing the Device Parameters 24 7 Technical Specifications 25 8 Default Communication Parameters 26 9 Kramer Protocol 3000 27 9 1 Switching Protocols 27 9 2 Kramer Protocol 3000 Syntax 28 9 3 Kramer Protocol 3000 Commands 31 10 Hex Table Protocol 2000 34 11 Kramer Protocol 2000 35 Figures Figure 1 VS 88FO 8x8 3G HD SDI Fiber Optic Matrix Switcher Front Panel 6 Figure 2 VS 88FO 8x8 3G HD SDI Fiber Optic Matrix Switcher Rear Panel 7 Figure 3 Connecting the VS 88FO 10 Figure 4 Installing the SFP Modules 11 Figure 5 DIP Switch Settings 13 Figure 6 Local Area Connection Properties Window 16 Figure 7 Internet Protocol TCP IP Properties Window 16 Figure 8 K U
12. 5 0 0 Gateway 0 0 0 0 First disconnect the power cord and then connect it again while pressing the Factory Reset button The unit powers up and loads its memory with the factory default definitions and erases all stored preset AC connector enabling power supply to the unit switch that turns the power to the unit ON 1 and OFF 0 Tel 07131 911201 Fax 07131 911203 ce info camboard de im Vertrieb von CAMBOARD Electronics 4 Installing in a Rack This section provides instructions for rack mounting the unit Before installing in a rack be sure that the environment is within the recommended range OPERATING TEMPERATURE STORAGE TEMPERATURE HUMIDITY 0 to 40 C 32 to 104 F 40 to 70 C 40 to 158 F 10 to 90 RHL non condensing CAUTION When installing on a 19 rack avoid hazards by taking care that 1 It is located within the recommended environmental conditions as the operating ambient temperature of a closed or multi unit rack assembly may exceed the room ambient temperature 2 Once rack mounted enough air will still flow around the machine 3 The machine is placed straight in the correct horizontal position 4 You do not overload the circuit s When connecting the machine to the supply circuit overloading the circuits might have a detrimental effect on overcurrent protection and supply wiring Refer to the appropriate nameplate ratings for information For example
13. For all other VS 88FO units in the middle of the line set the RS 485 TERM DIP switch OFF 5 4 Switching Genlocked Video Signals The genlock feature lets you switch genlocked video signals according to the timing of the GENLOCK reference input According to SMPTE RP 168 the sources must be genlocked to the GENLOCK input in order to switch cleanly 1 Connect the GENLOCK cable www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 2 To set the genlock timing press and hold for 3 seconds the appropriate input button as follows To Set Press and Hold Setting for 3 Seconds Displayed 1080i 60Hz 1080 60H 1080i p 50Hz IN2 1080 50H 720p S0HZ 720P 60H PAL 50Hz IN 4 PAL 50H Note When turning the machine ON the last stored setup is shown in the 7 segment display 5 5 Connecting the Ethernet Port You can connect the VS 88FO over the Ethernet in the following ways e For direct connection to the PC use a crossover cable see Section 5 5 1 e For connection using a network hub or network router use a straight through cable see Section 5 5 2 5 5 1 Connecting the Ethernet Port Directly to a PC Crossover Cable You can connect the Ethernet port of the VS 88FO to the Ethernet port on your PC via a crossover cable with RJ 45 connectors This type of connection is recommended for identifying the VS 88FO with the factory configured default IP address After
14. Insert the SFP module in an open slot and push it inward until it clicks 3 Remove the protective SFP cap from the end ofthe SFP 2 To remove an SFP module 1 Pullthe bail downward to release the SFP 3 2 Pull the SFP module out by the bail 4 3 If needed replace the protective cap over the fiber connectors Note When transporting or storing an unconnected device replace the SFP caps to protect against dust Figure 4 Installing the SFP Modules VS 88FO Connecting the VS 88FO Ja www camboard de Tel 07131 911201ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 5 2 Connecting the RS 232 Port You can connect to the VS 88FO using an RS 232 connection using for example a PC Note that a null modem adapter connection is not required To connect to the VS 88FO using RS 232 e Connect the RS 232 9 pin D sub rear panel port on the VS 88FO to the RS 232 9 pin D sub port on your PC Use a 9 wire straight cable only pin 2 to pin 2 pin 3 to pin 3 and pin 5 to pin 5 need to be connected 5 2 1 Determining the Machine Number Each unit must be identified by a unique machine number MACH Determine the machine number according to the following table e When using a single unit set the unit to Machine 1 e A master unit must be Machine 1 When connecting more than one VS 88FO set a different Machine for each unit The units do not have to be numbered sequentially but each unit must
15. NOTES on the above table NOTE 1 When the master switcher is reset e g when it is turned on the reset code is sent to the PC If this code is sent to the switchers it will reset according to the present power down settings NOTE 2 These are bi directional definitions That is if the switcher receives the code it will perform the instruction and if the instruction is performed due to a keystroke operation on the front panel then these codes are sent For example if the HEX code 01 85 88 83 was sent from the PC then the switcher machine 3 will switch input 5 to output 8 If the user switched input 1 to output 7 using the front panel keypad then the switcher will send HEX codes 41 81 87 83 to the PC When the PC sends one of the commands in this group to the switcher then if the instruction is valid the switcher replies by sending to the PC the same four bytes that it was sent except for the first byte where the DESTINATION bit is set high NOTE 3 SETUP 0 is the present setting SETUP 1 and higher are the settings saved in the Switcher s memory i e those used for Store and Recall NOTE 4 The reply to a REQUEST instruction is as follows the same instruction and INPUT codes as were sent are returned and the OUTPUT is assigned the value of the requested parameter The replies to instructions 10 and 11 are as per the definitions in instructions 7 and 8 respectively For example if the present status of mac
16. NSTRUCTION NO is the value to be set for N5 NO 2 BYTE Bit 7 Defined as 1 16 10 INPUT When switching i e instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switched Similarly if switching is done using the machine s front panel then these bits are set with the INPUT NUMBER which was switched For other operations these bits are defined according to the table 3 BYTE Bit 7 Defined as 1 O6 00 OUTPUT When switching i e instruction codes 1 and 2 the OUTPUT 7 bits is set as the output number which is to be switched Similarly if switching is done using the machine s front panel then these bits are set with the OUTPUT NUMBER which was switched For other operations these bits are defined according to the table 4 BYTE Bit 7 Defined as 1 Bit 5 Don t care OVR Machine number override M4 M0 MACHINE NUMBER Used to address machines in a system using their machine numbers When several machines are controlled from a single serial port they are usually configured together with each machine having an individual machine number If the OVR bit is set then all machine numbers will accept implement the command and the addressed machine will reply For a single machine controlled using the serial port always set M4 MO 1 and make sure that the machine itself is configured as MACHINE NUMBER 1 Note All values in the table are decimal u
17. P An SFP is a small form factor pluggable transceiver that is a compact hot swappable input output transceiver used in data communication and telecommunications networks The SFP interfaces between communication devices like switches routers and fiber optic cables and performs conversions between optical and electrical signals The SFP transceiver is specified by the SFP Transceiver Multisource Agreement MSA which was developed and is followed by different transceiver manufacturers SFP transceivers have a wide range of detachable interfaces to multimode single mode fiber optics that allows users to select the appropriate transceiver according to the required optical range for the network The VS 88FO supports use of non MSA SFP Transceiver Multisource Agreement video modules and MSA communication modules The optical transceiver modules are engineered for exceptional performance in the presence of SDI pathological patterns The transceivers feature best in class optical receiver sensitivity for SMPTE 259M SMPTE 344M SMPTE 292M and SMPTE 424M serial rates to provide superior optical link budget and robustness 3 2 Defining the VS 88FO 8x8 3G HD SDI Fiber Optic Matrix Switcher This section defines the VS 88FO www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics e O O 3 M9IAJ9AQ o 9 Waa OOOODDODOO DO O sbo o oo oo s 8x8 3G
18. PLOAD Main Screen 17 Figure 9 Connect Screen 18 Figure 10 Device Properties Screen 18 www camboard de Tel 07131 91120 1ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 1 Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront the video audio presentation and broadcasting professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Routers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters and GROUP 11 Sierra Products Congratulations on purchasing your Kramer VS 88FO 8x8 3G HD SDI Fiber Optic Matrix Switcher which is ideal for the following typical applications e Professional broadcasting and production studios e Presentation applications www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 2 2 1 2 2 www ca Getting Started We recommend that you e
19. ROTOCOL TCP UDP transport layer protocol PORT Ethernet port that accepts Protocol 3000 commands 1 65535 User defined port 0 Reset port to factory default 50000 for UDP 5000 for TCP www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 10 Hex Table Protocol 2000 The following table lists the Hex values for a single machine MACHINE 1 out1 jour2 ours oure our ours IN 1 01 01 01 01 01 01 01 34 VS t Hex Table Protocol 2000 www camboard de Tel 07131 91120 ce info Qcamboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 11 Kramer Protocol 2000 The VS 88FO is compatible with Kramer s Protocol 2000 version 0 50 This RS 232 RS 485 communication protocol uses four bytes of information as defined below The default data rate is 9600 baud with no parity 8 data bits and 1 stop bit MSB LSB DESTI INSTRUCTION NATION 1 BYTE Bit 7 Defined as 0 D DESTINATION 0 for sending information to the switchers from the PC 1 for sending to the PC from the switcher N5 NO INSTRUCTION The function that is to be performed by the switcher s is defined by the INSTRUCTION 6 bits Similarly if a function is performed using the machine s keyboard then these bits are set with the INSTRUCTION NO which was performed The instruction codes are defined according to the table below I
20. Recalling an Input Output Configuration To recall an input output configuration do the following 1 Press the RCL button The RCL button flashes 2 Press the appropriate IN or OUT SELECT button the button number corresponds to the preset number The chosen preset configuration is restored from memory Note Recalling an undefined setup gives an error indication ALL 0 6 1 8 Locking the Front Panel Lock the front panel buttons to prevent unwanted key presses from changing the existing setup e To lock the front panel press and hold the LOCK key for three seconds The LOCK key illuminates and the front panel keys are inactivated e To unlock the front panel press and hold the illuminated LOCK key until the light turns off The front panel keys are activated Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 6 1 9 Switching Protocols You can operate the VS 88FO using either the KRAMER 2000 or the default KRAMER 3000 serial protocol e To choose the Kramer 2000 protocol instead of the default Protocol 3000 press OUT 1 and OUT 2 at the same time OUT 1 flashes briefly if the change was made correctly e To revert to the Kramer 3000 protocol press OUT 1 and OUT 3 at the same time OUT 1 flashes briefly if the change was made correctly If an error is indicated retry the previous action or choose a new action 6 2 Using Serial Commands To operate the VS 88FO using serial commands Kramer provides free control sof
21. Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual e Use Kramer high performance high resolution cables Use only the power cord that is supplied with this machine Go to http www kramerelectronics com to check for up to date user manuals application programs and to check if firmware upgrades are available where appropriate Achieving the Best Performance To achieve the best performance Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Do not secure the cables in tight bundles or roll the slack into tight coils e Avoid interference from neighboring electrical appliances that may adversely influence signal quality Position your Kramer VS 88FO away from moisture excessive sunlight and dust This equipment is to be used only inside a building It may only be connected to other equipment that is installed inside a building Safety Instructions Caution There are no operator serviceable parts inside the unit 5 Warning Use only the power cord that is supplied with the unit Warning Do not open the unit High voltages can cause electrical shock Servicing by qualified personnel only Warning Disconnect the power and unplug the unit from the wall before installing mboard de Te
22. ace Parameters A sequence of alphameric ASCII characters 0 9 A Z a z and some special characters for specific commands Parameters are separated by commas Message string Every command entered as part of a message string begins with a message starting character and ends with a message closing character Note A string can contain more than one command Commands are separated by a pipe character Message starting character f For host command query For machine response Device address Optional for K NET K NET Device ID followed by Query sign follows some commands to define a query request Message closing character CRI For host messages carriage return ASCII 13 ICRLF For machine messages carriage return ASCII 13 line feed ASCII 10 Command chain separator character When a message string contains more then one command a pipe character separates each command Spaces between parameters or command terms are ignored ocol www camboard de Tel 07131 911201ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 9 2 7 Entering Commands You can directly enter all commands using a terminal with ASCII communications software such as HyperTerminal Hercules etc Connect the terminal to the serial Ethernet or USB port on the Kramer device To enter ICRI press the Enter key LF is also
23. air and restore this product to its proper operating condition Kramer Electronics will also pay the shipping costs necessary to return this product once the repair is complete 2 Replace this product with a direct replacement or with a similar product deemed by Kramer Electronics to perform substantially the same function as the original product 3 Issue a refund of the original purchase price less depreciation to be determined based on the age of the product at the time remedy is sought under this limited warranty What Kramer Electronics will not do Under This Limited Warranty If this product is returned to Kramer Electronics or the authorized dealer from which it was purchased or any other party authorized to repair Kramer Electronics products this product must be insured during shipment with the insurance and shipping charges prepaid by you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of this product from or into any installation Kramer Electronics will not be responsible for any costs related to any setting up this product any adjustment of user controls or any programming required for a specific installation of this product Howto Obtain a Remedy underthis Limited Warranty To obtain a remedy under this limited warranty you must contact either the authorized Kramer Electronics reseller from wh
24. any installation any unauthorized tampering with this product any repairs attempted by anyone unauthorized by Kramer Electronics to make such repairs or any other cause which does not relate directly to a defect in materials and or workmanship of this product This limited warranty does not cover cartons equipment enclosures cables or accessories used in conjunction with this product Without limiting any other exclusion herein Kramer Electronics does not warrant that the product covered hereby including without limitation the technology and or integrated circuit s included in the product will not become obsolete or that such items are or will remain compatible with any other product or technology with which the product may be used How Long Does this Coverage Last Seven years as of this printing please check our Web site for the most current and accurate warranty information Whois Covered Only the original purchaser of this product is covered under this limited warranty This limited warranty is not transferable to subsequent purchasers or owners of this product What Kramer Electronics will do Kramer Electronics will at its sole option provide one of the following three remedies to whatever extent it shall deem necessary to satisfy a proper claim under this limited warranty Elect to repair or facilitate the repair of any defective parts within a reasonable period of time free of any charge for the necessary parts and labor to complete the rep
25. e 3G HD SDI video players connected to a Kramer 690T transmitter www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 5 Connect the OUT connectors to up to eight fiber optic acceptors for example a Kramer 690R receiver connected to 3G HD SDI displays 6 Set the Machine and termination DIP switches see Section 5 2 1 7 Optionally connect Agenlock source to the GENLOCK BNC connector The LOOP BNC connector to the GENLOCK connector of the next unit in the line and release the TERM button for looping Push in to terminate the input Release when the input extends to another unit 8 Connect a PC and or controller if required to the RS 232 port see Section 5 3 and or the RS 485 port see Section 5 3 and or the Ethernet connector see Section 5 5 9 Connect the power cord We recommend that you use only the power cord that is supplied with this machine RS 232 woot 0 dn woo oi dn P gt Control PC i i 3G SDI Video 3G SDI Video 3G SDI Video 3G SDI Video T Player 2 Player 1 Display 1 Display 2 Figure 3 Connecting the VS 88FO EUM VS 88FO Connecting the VS 88FO www camboard de Tel 07131 911201ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 5 1 Installing the SFP Modules To install an SFP module 1 Make sure the bail removal handle is closed in an upward position as shown in 1 2
26. e UNKNOWN Unit Model File CRC UNKNOWN Serial Number Progress UDP Local Port 0 TCP Local port Donot check CRC J K Net ID MAC IP Gateway Mask Firmware Figure 8 K UPLOAD Main Screen 2 Click the Connect button The Connect screen appears VS 88FO Connecting the VS 88FO Nez www camboard de Tel 07131 91120 1ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics Connection Method Ethernet iP 192 168 001 039 Port 50000 C Serial C0M3 z C uss COMIO CB CB Figure 9 Connect Screen 3 Connect a USB cable from a USB port on the PC to the USB port on the VS 88FO You can also connect to the PC using the Ethernet or a serial connector 4 Check USB as the connection method and select the COM port from the USB drop down list 5 Click Connect The K UPLOAD screen appears as in Figure 10 Mi K UPLOAD x Fie Heb Device Properties Upload File Connection UDP on 192 168 001 039 SelectFile Unit Name KRAMER_1225 Fil le Type UNKNOWN a Unit Model File CRC UNKNOWN Serial Number Progress 0 UDP Local Port 50000 TCP Local port 5000 T Donot check CRC CEE K NetID 01 MAC IP 192 168 001 039 Galeway 000 000 000 000 Mask 255 255 000 000 Firmware Figure 10 Device Properties Screen 6 If required make changes and click Save If not click Exit EE VS 88FO Connecting the VS 88FO www camboard de Tel 07131 911201ce info camboard de
27. e or a network in use with DNS feature on MACHINE NAME Up to 14 alphameric chars Machine factory name Model name last 4 digits from serial number 9 3 8 Network Setting Commands yntax Response Set IP address NET IP IP ADDRESS NET IP IP ADDRESS RESULT Short form NTIP Read IP address NET IP NET IP IP ADDRESS Short form NTIP Read MAC address NET MAC NET MAC VAC ADDRESS Short form NTMC Set subnet mask NET MASK SUBNET MASK NET MASK SUBNET MASK RESULT Short form NTMSK Read subnet mask NET MASK NET MASK SUBNET MASK Short form NTMSK Set gateway address NET GATE IGATEWAY ADDRESS NET GATE GATEWAY ADDRESS Short form NTGT RESUL Read subnet mask NET GATE NET GATE GATEWAY ADDRESS Short form NTGT Set DHCP mode NET DHCP DHCP MODE NET DHCP bHCP MODE RESULT Short form NTDH Read subnet mask NET DHCP NET DHCP DHCP MODE Short form NTDH DHCP MODE 0 Don t use DHCP Use IP set by factory or IP set command T Try to use DHCP if unavailable use IP as above Change protocol ETH PORT PROTOCOL POR ETH PORT PROTOCOL PORT RESULT Ethernet port Short form ETHP Read protocol ETH PORT PROTOCOL ETH PORT PROTOCOL PORT Ethernet port Short form ETHP P
28. ect damages or the limitation of liability to specified amounts so the above limitations or exclusions may not apply to you Exclusive Remedy TO THE MAXIMUM EXTENT PERMITTED BY LAW THIS LIMITED WARRANTY AND THE REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES REMEDIES AND CONDITIONS WHETHER ORAL OR WRITTEN EXPRESS OR IMPLIED TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IF KRAMER ELECTRONICS CANNOT LAWFULLY DISCLAIM OR EXCLUDE IMPLIED WARRANTIES UNDER APPLICABLE LAW THEN ALL IMPLIED WARRANTIES COVERING THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL APPLY TO THIS PRODUCT AS PROVIDED UNDER APPICABLE LAW IF ANY PRODUCT TO WHICH THIS LIMITED WARRANTY APPLIES IS A CONSUMER PRODUCT UNDER THE MAGNUSON MOSS WARRANTY ACT 15 U S C A 82301 ET SEQ OR OTHER APPICABLE LAW THE FOREGOING DISCLAIMER OF IMPLIED WARRANTIES SHALL NOT APPLY TO YOU AND ALL IMPLIED WARRANTIES ON THIS PRODUCT INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR THE PARTICULAR PURPOSE SHALL APPLY AS PROVIDED UNDER APPLICABLE LAW Other Conditions This limited warranty gives you specific legal rights and you may have other rights which vary from country to country or state to state This limited warranty is void if i the lab
29. el bearing the serial number of this product has been removed or defaced ii the product is not distributed by Kramer Electronics or iii this product is not purchased from an authorized Kramer Electronics reseller If you are unsure whether a reseller is an authorized Kramer Electronics reseller please visit our Web site at www kramerelectronics com or contact a Kramer Electronics office from the list at the end of this document Your rights under this limited warranty are not diminished if you do not complete and return the product registration form or complete and submit the online product registration form Kramer Electronics thanks you for purchasing a Kramer Electronics product We hope it will give you years of satisfaction mr VS 88FO Kramer Protocol 2000 www camboard de Tel 07131 911201ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com KRAMER E mail info kramerel com SAFETY WARNING Disconnect the unit from the power m supply before opening and servicing Laser Compliance LASER PRODUCT Laser Class acc 21 CFR 1040 and Class 1 per IEC 60825 1 2900 300097 Rev 3 www camboard de Tel 07131 911201ce info camboard de Fax 07131 911203
30. esponse is sent for each command after processing S 88FO Kramer Protocol 30 www cambo rd de Tel 07131 911201ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 9 3 4 Preset Commands Command Store current connections to PRST STO PRESET PRST STO PRESET RESULT preset Short form PSTO PRESET Recall saved preset PRST RCL PRESE PRST RCL PRESET RESULT Short form PRCL Delete saved preset PRST DEL PRESE PRST DEL PRESET RESULT Short form PDEL PRESE Read video connections from PRST VID PRESET OUT PRST VID PRESET Saved preset Short form PVID PRESET OUT PRST VID PRESET PRST VID PRESET Read saved presets list PRST LST PRST LST PRESET PRESET Short form PLST Parameter Description PRESET Preset number OUT Output in preset to display for all Examples Store current video connections PRST STO SICH PRST STR 5 OKICRLF to preset 5 Recall video connections from PRCL 3 PRST RCL 3 OKICRLF preset 3 Show source of video output 2 PRST VID 3 2 PRST VID 3 422 CRLF from preset 3 9 3 5 Operation Commands Command Response Lock front panel LOCK FP LOCK MODE LOCK FP LOCK MODE RESULT Short form LCK LOCK MODE
31. for fuse replacement see the value printed on the product label 5 The machine is earthed grounded in a reliable way and is connected only to an electricity socket with grounding Pay particular attention to situations where electricity is supplied indirectly when the power cord is not plugged directly into the socket in the wall for example when using an extension cable or a power strip and that you use only the power cord that is supplied with the machine To rack mount a machine 1 Attach both ear brackets to the machine To do so remove the screws from each side of the machine 3 on each side and replace those screws through the ear brackets 2 Place the ears of the machine against the rack rails and insert the proper screws not provided through each of the four holes in the rack ears Note In some models the front panel may feature built in rack ears Detachable rack ears can be removed for desktop use Always mount the machine in the rack before you attach any cables or connect the machine to the power If you are using a Kramer rack adapter kit for a machine that is not 19 see the Rack Adapters user manual for installation instructions available from our Web site www camboard de VS 88FO Installing in a Rack Tel 07131 91120 1ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 5 Connecting the VS 88FO This section describes how
32. hine number 5 is breakaway setting then the reply to the HEX code 0B 80 80 85 would be HEX codes 4B 80 81 85 NOTE 8 The reply is as in TYPE 3 above except that here the OUTPUT is assigned with the value 0 if the setup is not defined no valid input is detected or 1 if it is defined valid input is detected gt l 2000 Tel 07131 911201ce en de Fax 07131 911203 www camboard de im Vertrieb von CAMBOARD Electronics NOTE 9 An error code is returned to the PC if an invalid instruction code was sent to the switcher or if a parameter associated with the instruction is out of range e g trying to save to a setup greater than the highest one or trying to switch an input or output greater than the highest one defined This code is also returned to the PC if an RS 232 instruction is sent while the machine is being programmed using the front panel Reception of this code by the switcher is not valid NOTE 13 This is a request to identify the switcher s in the system Ifthe OUTPUT is set as 0 and the INPUT is set as 1 2 5 or 7 the machine will send its name The reply is the decimal value of the INPUT and OUTPUT For example for a 2216 the reply to the request to send the machine name would be HEX codes 7D 96 90 81 i e 1284ect 22dec for 2 byte and 1284ec 164 for 3 byte If the request for identification is sent with the INPUT set as 3 or 4 the appropriate machine will send its software version number Again
33. his instruction is sent the unit will respond to the ASCII command set defined by the OUTPUT byte The ASCII command to operate with the HEX command set must be sent in order to return to working with HEX codes NOTE 25 For units which detect the validity of the video inputs Instruction 16 will be sent whenever the unit detects a change in the state of an input in real time For example if input 3 is detected as invalid the unit will send the HEX codes 10 83 84 81 If input 7 is detected as valid then the unit will send HEX codes 10 87 85 81 if amer Protocol 2 mer Protocol 2000 JE ir ard de Tel 07131 91120 1ce info camboard de Fax 07131 911203 www cambo im Vertrieb von CAMBOARD Electronics LIMITED WARRANTY The warranty obligations of Kramer Electronics for this product are limited to the terms set forth below Whatis Covered This limited warranty covers defects in materials and workmanship in this product What is Not Covered This limited warranty does not cover any damage deterioration or malfunction resulting from any alteration modification improper or unreasonable use or maintenance misuse abuse accident neglect exposure to excess moisture fire improper packing and shipping such claims must be presented to the carrier lightning power surges or other acts of nature This limited warranty does not cover any damage deterioration or malfunction resulting from the installation or removal of this product from
34. im Vertrieb von CAMBOARD Electronics KRAMER ELECTRONICS LTD KRAMER USER MANUAL MODEL VS SSFO 8x8 3G HD SDI Fiber Optic Matrix Switcher P N 2900 300097 Rev 3 www camboard de Tel 07131 91120 1ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics This guide helps you install and use your product for the first time For more detailed information go to http www kramerelectronics com support product_downloads asp to download the latest manual or scan the QR code on the left Step 1 Check what s in the box X VS 88FO 8x8 3G HD SDI i Rubber feet Fiber Optic Matrix Switcher 1 Quick Start sheet A 1 Power cord 1 Set of rack ears Step 2 Install the VS 88FO Mount the machine in a rack using the included rack ears or attach the rubber feet and place on a table Step 3 Connect the inputs and outputs Fiber Optic Receiver Computer Network Controller Control Step 4 Connect the power u Connect the power cord to the VS 88FO and plug it into the mains electricity Step 5 Set the VS 88FO Set the machine number and RS 485 termination DIP switches zz 7 A amp a m 2 MACH Step 6 Operate the VS 88FO Operate via the front panel network RS 232 or RS 485 controllers www camboard de Tel 07131 911201ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics Contents 1 Introduction 1
35. is device Parameter is out of range ERROO3 Unauthorized access command run without the ERROO4 matching login 9 3 3 Basic Routing Commands Command Syntax Response Switch video VID N oUT ee VID IINPIOUT IIN gt JOUT RESULT Short form V IN gt OUT ID Read video connection VID V Short form V VID VID N 1 N22 IN gt OUT Parameter Description in Input number or 0 to disconnect output gt Connection character between in and out parameters OUT Output number or for all outputs Examples Switch video input 2 to output 4 v 2 gt 4ICRI VID 2 gt 4 OKCRLF Switch video input 4 to output 2 6 VID 4 gt 2 6 VID 4 gt 2 OKICRLF in machine number 6 Disconnect video output 4 AV 0 gt 4 OKICRLF RL Switch video input 3 to all VID 3 gt OKICRLF outputs Chaining V 1 gt V 324 222 2 gt 1 0 gt 2 V 3 gt 9 V CR multiple 1 Switch video from input 1 to all outputs VID 1 gt OKICRLF commands 2 Switch video input 3 to output 4 video input 2 to 7VID 3 gt 4 2 gt 2 2 gt 1 022 output 2 video input 2 to output 1 and disconnect video OKICRLF output 2 3 Switch video input 3 to output 9 non existent VID ERR003 CRLF 4 Get status of all video links VID 2 gt 1 022 1 gt 3 3 gt 4 CRLF Command processing begins after entering CR A r
36. l 07131 911201ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 2 3 Recycling Kramer Products The Waste Electrical and Electronic Equipment WEEE Directive 2002 96 EC aims to reduce the amount of WEEE sent for disposal to landfill or incineration by requiring it to be collected and recycled To comply with the WEEE Directive Kramer Electronics has made arrangements with the European Advanced Recycling Network EARN and will cover any costs of treatment recycling and recovery of waste Kramer Electronics branded equipment on arrival at the EARN facility For details of Kramer s recycling arrangements in your particular country go to our recycling pages at http Avww kramerelectronics com support recycling www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 3 Overview The VS 88FO is a high performance matrix switcher for fiber optic signals It can switch any or all inputs to any or all outputs simultaneously In particular the VS 88FO features A maximum data rate of up to 3Gbps enabling it to be used for standard definition high definition and the new 3G high definition serial digital video signals 3G HD SDI A range of up to 40km depending on the SFP module used HDTV compatibility A single mode SFP small form factor pluggable SDI fiber optic connector for the input and the output A looping analog sync for genlock bi leve
37. l and tri level sync compatible Selectable sync signal termination Automatic reclocking and equalization Active input reporting where each input LED on the front panel automatically lights when the unit detects a video signal on that input Multiple memory locations that store multiple switches as presets salvos to be recalled and executed when needed A Take button that executes multiple switches all at once Vertical interval switching that synchronizes either to an external reference or to the incoming video in compliance with SMPTE RP 168 Flexible control options including front panel RS 232 K router Windows based software is included RS 485 Ethernet and IR Laser Class acc 21 CFR 1040 and Class 1 per IEC 60825 1 compliance The VS 88FO is housed in a 19 1U rack mountable enclosure and is fed from a 100 240V AC universal switching power supply www camboard de Tel 07131 911201ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics The unit can be controlled using the front panel buttons or using e An RC IR3 infrared remote control transmitter included e Remotely by RS 232 or RS 485 serial commands transmitted by a PC touch screen system or other serial controller e The Ethernet By default the VS 88FO is controlled using the Kramer 3000 protocol see Section 6 1 9 for details of how to switch to Protocol 2000 and Section 9 for the relevant protocol commands 3 1 Defining the SF
38. lowing 1 Press an OUT SELECT button from 1 to 8 or the ALL button The 7 segment display flashes 2 Press an IN SELECT button from 1 to 8 or the OFF button for immediate switching The selected input switches to the selected output The digits displayed in the 7 segment display the appropriate change 6 1 5 Switching in the CONFIRM Mode To switch in the CONFIRM mode when the TAKE button is illuminated do the following 1 Press an OUT IN combination The 7 segment display flashes The timeout lasts for 10 seconds 2 Press the TAKE button to confirm the action The 7 segment display stops flashing The TAKE button stays lit To confirm several actions in CONFIRM mode do the following 1 Press each OUT IN combination in sequence The 7 segment display flashes www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 2 Press the TAKE button to confirm all the actions The 7 segment display stops flashing The TAKE button stays lit 6 1 6 Storing an Input Output Configuration You can store up to 16 configurations in memory and recall them as presets using the eight IN SELECT buttons and the eight OUT SELECT buttons To store the current configuration do the following 1 Press the STO button The STO button flashes 2 Press one of the IN or OUT SELECT buttons The current configuration is stored in memory at the chosen preset number 6 1 7
39. nless otherwise stated VS 88FO Kramer Protocol 2000 ES www camboard de Tel 07131 911201ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics INSTRUCTION DESCRIPTION INPUT OUTPUT RESET DEVICE 0 1 SWITCH VIDEO Set equal to video input which is to Set equal to video output which is 2 15 be switched to be switched DEFINITION FOR SPECIFIC INSTRUCTION STORE VIDEO STATUS RECALL VIDEO STATUS 0 disconnect 0 to all the outputs Set as SETUP 0 to store 1 to delete Set as SETUP 2 3 15 2 3 15 REQUEST STATUS Set as SETUP Equal to output number whose 4 3 OF A VIDEO OUTPUT status is required REQUEST WHETHER SETUP 0 for checking if setup is defined 8 SETUP IS DEFINED 1 for checking if input is valid VALID INPUT IS DETECTED ERROR BUSY For invalid valid input i e 0 error 9 25 OUTPUT byte 4 or OUTPUT byte 1 invalid instruction 5 2 out of range this byte is set as the input 3 machine busy 4 invalid input 5 valid input LOCK FRONT PANEL 0 Panel unlocked 2 1 Panel locked REQUEST WHETHER 16 PANEL IS LOCKED joo 8 Protocol 30001 19 1 video machine name 0 Request first 4 digits 13 3 video software version 1 Request first suffix IDENTIFY MACHINE DEFINE MACHINE 1 for video 14 3 for SDI 4 for remote panel 5 for RS 422 controller 1 number of inputs 2 number of outputs 3 number of setups
40. om you purchased this product or the Kramer Electronics office nearest you For a list of authorized Kramer Electronics resellers and or Kramer Electronics authorized service providers please visit our web site at www kramerelectronics com or contact the Kramer Electronics office nearest you In order to pursue any remedy under this limited warranty you must possess an original dated receipt as proof of purchase from an authorized Kramer Electronics reseller If this product is returned under this limited warranty a return authorization number obtained from Kramer Electronics will be required You may also be directed to an authorized reseller or a person authorized by Kramer Electronics to repair the product If itis decided that this product should be returned directly to Kramer Electronics this product should be properly packed preferably in the original carton for shipping Cartons not bearing a return authorization number will be refused Limitation on Liability THE MAXIMUM LIABILITY OF KRAMER ELECTRONICS UNDER THIS LIMITED WARRANTY SHALL NOT EXCEED THE ACTUAL PURCHASE PRICE PAID FOR THE PRODUCT TO THE MAXIMUM EXTENT PERMITTED BY LAW KRAMER ELECTRONICS IS NOT RESPONSIBLE FOR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION OR UNDER ANY OTHER LEGAL THEORY Some countries districts or states do not allow the exclusion or limitation of relief special incidental consequential or indir
41. operating display Using the AT ONCE and CONFIRM Modes Choose to work in either the AT ONCE or the CONFIRM modes In the AT ONCE mode pressing an OUT IN combination switches the unit immediately The AT ONCE mode is faster since execution requires no user confirmation however there is no protection against pressing a wrong button In the CONFIRM mode the change does not take place until the TAKE button is pressed e You can key in several actions and then confirm them by pressing the TAKE button to simultaneously activate the multiple switches e Every action requires user confirmation This protects against erroneous switching due to human error pressing the wrong button e Execution is delayed until the user confirms the action www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 6 1 3 Toggling Between Modes To toggle between the AT ONCE and CONFIRM modes do the following 1 Press the TAKE button to toggle from the AT ONCE mode in which the TAKE button is not lit to the CONFIRM mode in which the TAKE button illuminates Actions now require user confirmation and the TAKE button illuminates 2 Press the illuminated TAKE button to toggle from the CONFIRM mode back to the AT ONCE mode TAKE button turns off and actions no longer require user confirmation 6 1 4 Switching in the AT ONCE Mode To switch an input to an output in the AT ONCE mode do the fol
42. rIN1 Ourin2 OUTN3 OUTIN4 SFP SFP UNT OurNB Deere RS 485 ETHERNE Feature GENLOCK BNC Connector TERM HI Z 75Q Pushbutton LOOP BNC Connector SFP SFP Out In Receptacles PROG UPDATE USB connector RS 232 9 pin D sub F Port MACH and PROG RS 485 TERM DIP switches RS 485 Terminal Block Port Ethernet RJ 45 Connector SFP SELECT Button FACTORY RESET Button lt rk Power Connector Power Switch and lt Fuse www camboard de Connects to the genlock source Function Press to terminate the genlock source 75Q or release for looping Connects to a display or the next chained Genlock connector Holds an SFP module in each OUT IN receptacle 1 8 Each SFP connects a double fiber cable to an input and output Connects to a computer to upgrade machine firmware Connects to the PC or the remote controller MACH DIP switches 1 4 set the Machine Number of the unit PROG DIP switch enables a microcontroller firmware upgrade RS 485 TERM DIP switch terminates the RS 485 line with a 120Q load Pins B and A are for RS 485 Pin G may be connected to the shield if required Connects to the PC or other serial controller through computer networking LAN Press for non MSA SFP Transceiver Multisource Agreement video module release for MSA communication module Press to reset to factory default definitions IP number 192 168 1 39 Mask 255 25
43. sent but is ignored by command parser For commands sent from some non Kramer controllers like Crestron some characters require special coding such as X Refer to the controller manual 9 2 8 Command Forms Some commands have short name syntax in addition to long name syntax to allow faster typing The response is always in long syntax 9 2 9 Command Chaining Multiple commands can be chained in the same string Each command is delimited by a pipe character When chaining commands enter the message starting character and the message closing character only once at the beginning of the string and at the end Commands in the string do not execute until the closing character is entered A separate response is sent for every command in the chain 9 2 10 Maximum String Length 64 characters 9 2 11 Backward Support Protocol 2000 is transparently supported by Protocol 3000 You can switch between protocols using a switch protocol command from either platform www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 9 3 Kramer Protocol 3000 Commands 9 3 1 Device Initiated Messages Command Syntax Switcher actions Video channel has switched breakaway mode VID IN gt OU 9 3 2 Result and Error Codes Syntax Command ran successfully no error ICOMMAND PARAMETERS OK Protocol Errors Syntax error ERROO1 Command not available for th
44. to connect the VS 88FO The VS 88FO can switch one of the eight fiber optic inputs to any or all of the eight fiber optic outputs as the example in Figure 3 shows Always switch off the power to each device before connecting it to your VS 88FO After connecting your VS 88FO connect its power and then switch on the power to each device The customer can replace any SFP module with a standard SFP module but Kramer guarantees correct operation only with Kramer supplied modules All SFP modules up to eight must be of the same type either MSA or non MSA Only modules Laser Class acc 21 CFR 1040 and Class 1 per IEC 60825 1 are allowed in this product SESS The following optional SFP modules are tested and approved for use with the VS 88FO e SFP IN OUT 2KM SFP Fiber Optic Module SM 2km 3G HD SDI Tx Rx e SFP IN OUT 30KM SFP Fiber Optic Module SM 30km 3G HD SDI Tx Rx e SFP IN OUT 40KM SFP Fiber Optic Module SM 40km 3G HD SDI Tx Rx To connect the VS 88FO do the following 1 If SFP modules are preinstalled in your unit go to step 4 below and ignore Steps 1 to 3 If not continue with step 2 2 Insert an SFP module into each IN OUT slot to be used see Section 5 1 3 Setthe SFP Select button on the rear panel depending on the type of SFP used Press in for Non MSA and release for MSA The setting is saved after powering the device ON 4 Connect up to eight fiber optic sources to the IN connectors for exampl
45. tware that you can download from the Kramer Electronics Web site e For an explanation of all KRAMER 3000 commands see Section 9 e For an explanation of all KRAMER 2000 commands see Section 10 6 3 Using the Infrared Remote Controller To operate the VS 88FO using the RC IR3 infrared remote controller see the User Manual packed with the remote controller See also the Kramer Web site www kramerelectronics com Note e You cannot change genlock timing from the remote control only from the front panel e The IR remote controls only 8 preset configurations equivalent to OUT 1 to OUT 8 www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 6 4 Upgrading the Firmware The VS 88FO uses a microcontroller that runs firmware located in FLASH memory The latest version of firmware and upgrade instructions can be downloaded from the Kramer Web site at www kramerelectronics com and updated in minutes using K UPLOAD The USB port is used for connecting the VS 88FO to a PC to transfer the data 6 5 Changing the Device Parameters To change the device parameters do the following 1 Connect a PC to the VS 88FO see Section 5 3 2 Open K UPLOAD see Section 5 6 3 Click the Connect button to open the Connect window 4 Choose the appropriate type of connection Ethernet Serial or USB and click Connect The Connect window disappears and the Device Properties become visible
46. w kramerelectronics com www camboard de Tel 07131 911201ce infio camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 9 2 Kramer Protocol 3000 Syntax Protocol 3000 communicates at a data rate of 115200 baud no parity 8 data bits and 1 stop bit 9 2 1 Host Message Format Start Address optional Body Delimiter 9 2 2 Simple Command Command string with only one command without addressing Body Command SP Parameter 1 Parameter 2 9 2 3 Command String Delimiter Formal syntax with commands concatenation and addressing Delimiter Destination_id Command 1 Parameter1_1 Parameter1_2 __ CR Command 2 Parameter2 1 Parameter2 2 DS Command 3 Parameter3 1 Parameter3 2 9 2 4 Device Message Format Start Address optional Body delimiter Send u Message LE 9 2 5 Device Long Response Echoing command Start Address optional Body l Delimiter I Sender_id Command SP Param1 Param2 result CRLF CRI Carriage return ASCII 13 0x0D LF Line feed ASCII 10 0x0A ISP Space ASCII 32 0x20 28 Kramer Protocol 3000 www camboard de Tel 07131 911201ce info camboard de Fax 07131 911203 im Vertrieb von CAMBOARD Electronics 9 2 6 Command Terms Command A sequence of ASCII letters A Z a z and Command and parameters must be separated by at least one sp

Download Pdf Manuals