Home

EndFaceData2 (2.2) User Manual

image

Contents

1. Documents and Settings E DRIVERS E E EFD Customer H n Ej EndFaceData E E EndFaceImage E E EndFaceImage 1109 e New Batch E EndFaceImage 2011 lE EndFaceImage 100723 v Location Make New Folder Batch EndFaceData2 2 2 User Manual Rev 1 5 2 2 Create New Directory in EndFaceData You can even create new directories in EndFaceData cx Mew Hatch Location AEFD Cusztomerz Batch DI D004 FIA DRIVERS H E EFD Customer E EFD Customer2 123123 E HUO1 DD01 EFD dn QCDS 1004 EFD F 0c09 1005 EFD Ej OC09 1006 EFD C x 01 0001 EFD e 2 FFR Peka Make New Folder Type the new folder name here EndFaceData2 2 2 User Manual Rev 1 5 3 QC Workflow in Manufacturing Industry In the QC department of a factory the following workflow can be used to screen out and put aside those fail fiber modules while keeping only those passed good fiber modules in the batch Produce Batches of Fiber Devices in Convenient Batch Size of 100 Pieces Each yy Open Main Batch to recerve TZ Image Analysis Ed Image Data C EFO Factery QCO9 1001 FIA Ne ASS fiber devicez AXE J ry ir Fie Options Help p T eari i Lnedimaga _LoadVidea lm 0 wet EE GOusB CAM to do check MM MINER s Keep all PASS devices m Main Total econ 18 menara TAS UT xv ng Ti quegli Batch Record 18 v mia V Fiberld
2. 1 2 Main Screens at Work 1 2 1 Image Analysis Screen the control panel EF Image Analysis EE File Options Help Load Image Load video USE LAM Image Sources for Analysis Record t Fiber ldi e Gotot Result Record Navigation Editing Total Record 14 Result Record Compilation C p Result Views Result Record in MA EndFaceData2 2 2 User Manual Rev 1 1 2 2 Image Data Screen the analysis result data amp thumb nails This screen defaults to show only one result record or the batch header at a time Image Data C MEndFacelmageWC X02 001 6 FIA Image File Name Defects Fass Date Time HPEGOOOS PNG Diameter Defects size Count Limit Count However user can double click at its top to expand it fully to show multiple result records at a time Image Data C EndFacelmage XX02 0016 FIA A Company Eternal Science 5 Location Hk Cable ID 54221 Job 123 Fibers From 1 To 14 Technician FH Date Time 2011 1014 v 131821 Notes All very dirty need extensive cleaning Fiber Face Image Analysis Batch Report Wire Image File Name Defects Pass Date Time MPEGODO2 PNG 24 Fail 11 10 14 Zone Diameter Defects Size Count Limit Count Pass 25uM 2uM so 2 Fail B 120uM 2uM lt 5 12 Fai B 120uM gt 5uM lt D g Fail C 130uM 88uM 99 0 Pass D 25
3. Jah B Fiba Frag Ta Tadinl clan Data Tima INI I Id 13 Hgtas leas Tram mut mazda Flla Haad Cant Lisit HETA PH Dl gta Infact Sira MPEn I7 PH Dims Dafasts Slo EndFaceData2 2 2 User Manual Rev 1 3 3 2 3 3 3 Soft Copies of Press Quality Batch Reports in PDF Format Files Alternatively user can also print an analysis result batch to an Adobe PDF printer User can select the Press Quality option while printing The soft copy report thus produced will allow zoom out to reveal very fine details of the end face image in Adobe PDF Reader on any PC However user must have obtained the Adobe PDF printer from Adobe and installed it on the PC printing the report On the PC reading the report the Adobe PDF reader must have been installed Sophisticated Report Viewing by Distributing Result Batch Files User can directly distribute the analysis result batch files to their clients This will allow the finest details and the greatest reviewing flexibility for the report receiver The report receiver can install the EndFaceData2 on their own PC and use its Reader mode to review and compile the reports in various flexible ways Please see the previous section 3 2 Analysis Result Filing Reviewing and Compilation for details The report receiver needs to obtain and install the free EndFaceData2 in Reader Mode Please see the following section 4 2 Reader Mode To distribute the batch XX01 0100 FIA us
4. 2100010035527 L Goot Gata Fiber 1D Wield 18 CAE ndF scelmage MIN 0002 4D Upon FAIL Move to B2 batch Lilies va Then Discard from Main Batch STAN EndFaceData2 2 2 User Manual Rev 1 5 4 Picking Samples from a Batch for Delivery When picking sample fiber modules from a pre checked batch the corresponding analysis result records can also be picked out and put together into a new batch to be ready for delivery with the modules Pick for Sub Batch Delivery with Data Files m EF Image Analysis TP e Load Image Load Video D Open the main batch from the factory store C09 1001 usBCAM Total Record 18 Create a new B2 batch to recerve the fiber devices to be delivered the location directory can be on a removable medium e g the USB Memory Stick at E P d DN01 0002 Pick each Fiber Device Double click at the prebvious Fiber Id TI Scan the bar code to goto the Fiber Id automatically it UN Discard 8 Copy tto 82 Copy ANH to BZ Move io Move ad sto B2 B2 E DNOT DOOC FiA Image Data CEO Factory 2009 1001 FA Move the Record from the main batch to the B2 batch Repeat 3 n until all fiber devices has been picked Company ETERHALSDEHCE Location Job H Technician Notesi Cave Profiles usedi o MO Optionally open the completed B2 batch as main batch Fiber Face Image Analvsis Batc
5. Cr a Clicking the following buttons will select different views of the end face image result shown in the Fiber End Face screen Red Spot button will highlight the detected defects of each defect class in each zone in red in turn Spots button will toggle showing the defect spots markup on and off Zones button will toggle showing the four zone circles the cross hair rulers and the scale ruler on and off The following are samples of the different views 2010 04 16 12 10 33 20151 04 16 12 10 33 TES Fiber End Face EX 2011 04 16 12 10 33 2010 04 16 12 10 33 EndFaceData2 2 2 User Manual Rev 1 3 2 5 Result Data Views Zones mummE Result Data Views Clicking the following buttons will select different views of the end face result data shown in the Image Data screen Details button will show the detail result records Image Data C MEndFacelmage XX02 0016 FIA Location ne p Cable ID LR Job Fromm J Tao A Toci I 7 Notes images from VSM3BU Fiber Face Image Analysis Batch Report Image File Name Defects Pass Date Time HPEGUOO PNG Diameter Defects Size Count Limit Count Pass gt full gt Full gt Y99uM 1 DuM Image File Name Defects Fass MPEGDODNOS PNG Diameter Defects Size Count Limit Image File Name Defects Pass EndFaceData2 2 2 User Manual Rev 1 Summary button will show the summary resu
6. 2 2 Create New Directory in EndFaceData ooooooWW 35 5 3 QC Workflow in Manufacturing Industry ooooo XX 36 5 4 Picking Samples from a Batch for Delivery Woo 37 5 5 Sample Check and Prita E 38 PROC ae aa aa tmm 39 AV III r E 39 Al Instal the BNA ata ema aman gama 39 A 1 2 Setup Default Company Name and Logo oooooW WWW 40 A2 Supported Fiber Scope Model Soo 40 152 ADEM MEG Fiber PEOM OS en men et en tete aan Sai 40 A 3 1 SM Fiber IPC 8497 1 for Single Mode Fiber 125um diameter 40 A 3 2 MM Fiber IPC 8497 1 for Multi Mode Fiber 125um diameter 4 A 3 3 SM 125um Fiber 250um Zone D for Single Mode Fiber 42 A 3 4 SM 125um Fiber 1 25mm Zone D for Single Mode Fiber 42 EndFaceData2 2 2 User Manual Rev 1 1 1 1 Overview Functions The main purpose of EndFaceData2 is to analyze the fiber end face images and to eive a quantitative measure of any defects on the fiber end face semi automatically It also provides facility to allow easy compilation filing reporting reviewing and distribution of the analysis results It stores all the analysis results 1n a collection called a batch User must open a batch before doing any analysis Everything can be traceable by respective ids and date time stamp like fiber id fiber image captured date time and analysis date time EndFaceData2 2 2 User Manual Rev 1
7. Opening a Batch User must open a batch first either new batch or an existing batch before any fiber end face analysis will be allowed User can create a new batch by clicking File New Batch Report or open an existing batch by clicking File Open Batch Report E Image Analysis Sele Options Help Mew Batch Report Open Batch Report Open Batch 2 Be Close Batch 2 Exit Scope Profiles A Scope Profile also called Camera Profile defines the various attributes of the fiberscope that will capture have captured the end face image for analysis Different models of fiberscope give different zoom size and various quality of images of fiber end faces The EndFaceData2 can accept fiber end face images from a number of defined models of fiberscope Please see the list of the supported models in the appendix A2 Supported Fiber Scope Models Before starting an analysis the matching Fiberscope Profile must be selected first EndFaceData2 2 2 User Manual Rev 1 ES Camera Profile Camera Profile is EE Picture Width Pixel Picture Height Pixel oom ull Pi el 1 381 097561 Horizontal Stretch 0 532 Moe Filter 2 3 1 Correct Camera Profile Selection A correct camera profile should give the result image as below with the fiber cladding perimeter lies between the Zone B and Zone C circles EndFaceData2 2 2 User Manual Rev 1 2 3 2 Incorrect Camera Profile
8. Selection An incorrect camera profile will give a wrong magnification scale ruler wrong zone areas and wrong defects classification The following are examples with wrong camera profile selection 2 3 3 Extremely Wrong Camera Profile Selection In case of an extremely mismatch camera profile the system will fail to recognize the fiber at all as shown below Shenzhen Eternal Science Development Co Ltd EndFaceData2 2 2 User Manual Rev 1 2 4 Fiber Profiles Fiber Profiles define the passing criteria of the fiber endface under test It defines the diameters of the four zones of interest of a fiber endface It also defines the allowable size and quantity of defects in each zone Four Fiber Profiles are defined Please see the definitions in appendix A 3 Defined Fiber Profiles Before starting an analysis the required Fiber Profile must be selected first FZ select Fiber Profile Seles Diameter Defects Size Limit Defects Count Limit EndFaceData2 2 2 User Manual Rev 1 2 5 Fiber End face Image Sources Three input sources of fiber end face images are accepted 1 e image files video files and real time video captures from a fiberscope connected as a USB CAMERA FZ Image Analysis E OJK Fille Options TEN P Total Record 14 2 5 1 Capture Image by Loading Image File Click the Load Image button and a window will show up to allow selecting the image file After selecting the reguired fi
9. in EFO Reader mode Press EndFaceData2 2 2 User Manual Rev 1 In Reader Mode user cannot do any end face image analysis work F2 Image Analysis Seles EZ Image Analysis Sele i Fie Options Help Options Help PETA rend A RN p E v Mew Batch Report I n m m oad Image Lr jad s Ideo Open Batch Report USE CAM Open Image Total Record Goto Open Batch 2 B2 Close Batch 2 Exit Summary Summary EZ Image Analysis EBR La Sa Select Fiber Profile Set Company amp Logo Total Record r M Usca H ae Ht PA Panu ali LU H Wo to B ce Ll I jn AI Summary EndFaceData2 2 2 User Manual Rev 1 9 5 1 5 1 1 Usage Tips New Batch Creation Batch name consists of a four character Batch Prefix followed by the second part which can be a sequence number or any meaningful short text string e g CUO1 0001 FIA CU01 0002 FIA CU01 BEIJING 110930 FIA Batch Prefix You can create your own four character Batch Prefix e g NEWP Simply type it in the New Batch screen when you need it It will be remembered once it is used But please don t create more than 20 Batch Prefix on a PC workstation Ez Image Analysis Seles l Options Help Mew Batch Report Open Batch Report e Mew Batch E E Location L SEFD Factary v Batch Cancel EndFaceData2 2 2 User Manual Rev 1 5 1 2 Quick Batch Creation with Batch Serial Number Batc
10. 0uM gt 10uM lt D Fai Wire Image File Name Defects Pass Date Time 2 2 WPEGOOO5 PNG 40 Fai 11 10 14 Zone Diameter Defects Size Count Limit Count Pass aA 5 AW ai EE 3 F B 120uM 2uM 5 18 Fail B 120uM gt 5ull lt D 18 Fail C 130uM gt 99uM 99 Pass D 250uM 1 0uM lt 0 Fail Wire Image File Name Defects Pass Date Time 3 3 MPEGOOO PNG 16 Fail 11 10 14 Diameter Defects Size Count Limit Count Pass EndFaceData2 2 2 User Manual Rev 1 1 2 3 Fiber End Face Screen the analysis result image MM Fiber End Face E Ak 04 16 12 03 19 Shenzhen Eternal Science Development Co Ltd EndFaceData2 2 2 User Manual Rev 1 2 2 1 Fiber End face Analysis System Startup Note the operation mode There are two working modes in the EndFaceData the full function mode and the Reader mode User must plug in the License Dongle first before starting the EndFaceData in order to enjoy the full functions of the software The following splash screen indicates that a valid License Dongle has been detected After showing for three seconds it will go on to show the main screens the Image Analysis screen and the Image Data screen e About EndFace Data FEE Z Ale SCIENCE EndFace Data 2 2 version 2 2 0 7 2011 07 Copyright 2011 ETERNAL SCIENCE All rights reserved License Number 15028440 80004300 EndFaceData2 2 2 User Manual Rev 1 2 2 2 3
11. Copy Record to B2 This will copy the valid current record in the primary batch to the secondary batch Copy All Record to B2 This will copy all the valid records in the primary batch to the secondary batch Move Record to B2 Move All Record to B2 In the primary batch after a record has been moved out to the secondary batch it will be shown with strike through lines and become invalid Any invalid record will not be copied out or moved out to any secondary batch again Image Data C EndFacelmage CU01 0001 FIA 1 Caml1 032211 233850 PNG B Vire ET File Name Defects Pass Fail Wire Image File Name Defects Pass 8 3 MPEG0003 48 PNG 27 Fall Zone Diameter Defects Size Count Limit Count Pass Z5uM gt ZuM lt 0 0 Pass B 120uM 2uM 5 16 Fail B 120uM gt 5uM lt I Fail 130uM gt 99uM 99 0 Pass D 250uM 1 uM D 0 Pass Date Time 11 09 02 Date Time 11 09 02 4 HEN i h d MS ME E gt z re Ee bet gt ra T C t VE A O Aeg EndFaceData2 2 2 User Manual Rev 1 3 3 Analysis Result Reporting and Distribution 3 3 1 Hard Copies of Batch Reports Simplest Way of Distribution User can print a result batch in full on paper for review and for hardcopy distribution This 1s the simplest way to distribute a batch of analysis results Flbar Fasa maga analis Bata Raprt Lama Etamal xl anc Lati m Gabla 10
12. EndFaceData2 2 2 User Manual ETERNAL EndFaceData2 2 2 User Manual Rev 1 Contents D ul ae 1 1 1 Benoa UU EE E I 1 Lo Nia Screen WN oa a a 2 1 2 1 Image Analysis Screen the control panel 2 12 Image Data Screen the analysis result data amp thumb nails 3 1 2 3 Fiber End Face Screen the analysis result 1mage 4 2s Fib nat Aa E 5 2 1 System Startup Note the operation mode ooooooWo oo 5 2 2 Opening o PIT one en Um 6 29 Scope BO Eno ee nun DR DR CODE Ded 6 23 1 Correct Camera Profile Selection 1 1 240002000vv si ata Pri V vb Skal um aran a alana 7 2 2 2 Incorrect Camera Profile Selection oooaaa 8 2 3 3 Extremely Wrong Camera Profile Selection aaaaiiiaaissssaaisasassssaaaaaaaa 8 P ber On ES RR ETE EE 9 23 Fiber End Taice Image SOUECES sn aa some ete AP ebi 10 2 5 1 Capture Image by Loading Image File ooooo 10 252 Capture Image by Loading Video File aaaaaaiiiaaassssati asasssnnaaaaaasaaa 1 2 5 3 Capture Image Real Time from USB Camera 12 2 6 Amal Ss Se SUB aos om neon n an mm sat AA an BAD ses ap 13 3 Analysis Result Management oo Woo aa 14 3 1 Major Terms and COnceptS o o co Woo o o iooo o oo moo o cco o w 0 Wo mo o m o i 14 3 1 1 Report Baki an l a a s E 14 2 2 Fiber Id amp End Face Image File Name 15 3 1 3 Anal
13. e files remain in the batch director If this is not desired when distributing reports user can use Copy All Record to B2 to copy only all the valid result data and images to a brand new batch for distribution Wire Id Edit Wire Id is a number used to identify a fiber end face It is assigned sequentially by the EndFaceData upon image analysis It can also be changed by the user anytime Whereas the Fiber Id is assigned while image capturing and cannot be changed afterwards Wire Id is useful when the user cannot dictate the Fiber Id during image capturing and has to assign an Id afterwards EndFaceData2 2 2 User Manual Rev 1 3 2 8 Analysis Result Compilation User can extract any result records from any batch and append them into another batch either for report printing or for batch report distribution later User can call up any result record from the primary open batch and then copy the record to the end of the secondary batch that has been opened or created via the B2 button e Image Analysis Sele Fie Options Help Load Video USB CAM Total Record 15 Record H 15 v Geto amp gt Goto Fiber ID Copy toB2 Copy All to B2 Result Record Move All to B2 Compilation C sEndFacelmage 2 001 7 Secondary Batch B2 CN a 2 New Open Batch File 2 Bil Location C EndFacelmage sm Mew Batch 2 Open Batch 2 Batch DNI 0001 FIA EndFaceData2 2 2 User Manual Rev 1
14. er should also distribute the directory XX01 0100 EFD together EndFacelmage m E File Edit View Favorites Tools KsAD1 0100 EFD amp n1 0101 EFD 2 401 0100 FIA 401 0101 FTA EndFaceData2 2 2 User Manual Rev 1 4 License Dongle and Reader Mode 4 1 License Dongle To enable the full functioning of the EndFaceData2 you need to plug the license control dongle into a USB port of your PC all the time The license control dongle can be purchased through our sales channels Please see the appendix With the license dongle plugged in the following splash screen will be shown for 3 seconds during start up Ez About EndFace Data m Ed ETERN IZ Ale SCIENCE EndFace Data 2 2 version 2 2 0 7 2011 0 Copyright 2011 ETERNAL SCIENCE All rights reserved License Number 15026440 80004300 EndFaceData2 2 2 User Manual Rev 1 4 2 Reader Mode The Reader Mode is designed for any user who has received end face image analysis result batches from others to review report and even to re compile the received result batches If the EndFaceData starts up without the license control dongle then it can only work in Reader Mode with the following start up screen IZ AN SCIENCE E EndFace Data 2 2 version 2 2 0 7 2011 07 Copyright 2011 ETERNAL SCIENCE All rights reserved Yo License Dongle Please plug in bup it now Press Retry after plugging in the dongle Fress Header to enter
15. ev 1 Appendix A 1 System Installation A 1 1 Install the EndfaceData The release contents may come in the form of a CD or in the form of a downloadable zip file that should be unzipped to a CD or any convenient directory Then the installation procedures will be the same as the following Contents of the release CD EndFaceData2 EFD 2 2 0 7 ReleaseDoc txt This Document setup exe The installer for the EndFaceData2 2 2 0 7 application and some pre requisites EM2820 USB Video 5 7 0129 The USB Video Driver for the Fiber Scope Probe To install the application To install the EndFaceData2 simply insert the CD into your CD drive It will auto run the installer However if the auto run does not happen simply double click the setup exe on the CD e g ENsetup exe You should substitute the letter E with your CD s drive letter in this case Then simply follow the on screen prompts until the installation is completed To install the USB Video Driver 1 Plug the Fiber Scope Probe into a USB port 2 When the PC prompts you for the USB device driver for the new detected USB hardware Device 2820 ask it to search the relevant directory in your inserted CD for the driver 1 e if Eis your CD s drive letter enter the directory ENEM2820 USB Video 5 7 0129 3 Follow the on screen prompts until the installation is completed EndFaceData2 2 2 User Manual Rev 1 A 1 2 Setup Default Company Name and Logo Every time
16. h File name can be a Batch Prefix followed by a Serial Number which is auto incremented e g CUO1 0001 FIA CU01 0002 FIA In this case no typing reguired just click click and the new file name and the new batch will be created automatically A Image Analysis SEE File Options Help New Batch Report Open Batch Report Location C EndF acelmage h Batch cum 0002 FIA a Image Data C EndFacelmage CU01 0002 FIA Company BEE Location Cable ID Job Fibers From To Technician Date Time 2011 0903 v 21 05 44 Notes 5 1 3 Meaningful Text for Batch Name Alternatively user can choose to use a short text as the batch file name e g CUOI BEIJING 110930 FIA e Mew Batch Location CE ndF acel mage v Batch CUO w BEIJING 10930 FIA EndFaceData2 2 2 User Manual Rev 1 5 2 Working Directory Upon installation the default working directory is C EndFaceImage However user can use other directories or even create more new directories in EndFaceData 5 2 1 Select Other Directory You can select other directories and elect to use them whenever you like The directories up to the 10 most recently used directories will be remembered once you have used them FZ New Batch ox Location CNEndF acel mage LJ Browse For Folder Batch CUM 0002 FIA TEM PRELOAD Cr
17. h Report Tire Image Fila Hane amp enter any delivery notes into its batch header EndFaceData2 2 2 User Manual Rev 1 5 5 Sample Check and Print When sample checking fiber modules from a batch the corresponding analysis result records can also be picked out and put together into a new batch ready to be print together in a nice looking report Sample Check and Print ma aras I HAS oen LET ih T Loadimage Load idea D Open the main batch USECAM Total Record 18 Record 18 Create a new B2 batch to recerve the fiber devices for Sample Check and Print Fiber g Goot Wield 18 Edi Discard 8 eee ee eee Copy tto 82 Copy ANH to BZ _Move to Move Al toB2 SAEFD acton xD1 0003 FIA Pick each Fiber Device Sample 3 Double click at the previous Fiber Id HHA Scan the bar code to goto the Sample Fiber Id automatically Move the Record from the mam batch to the E2 batch Image Data CEO Factory 2009 1001 FA Company ETERHALSCENCE 5 Repeat 3 ali S Location Job H T 6 Open the completed B2 batch as main batch i Technician TIT TI a HE irr Prof los vad O amp optionally enter notes mto batch header Ti Camera Hl CE dUU D 5um FPi 17 Fiber Face image Analvsis Batch Report B Tire maze Fila Hane 9 Print the Sample Batch Report J i EndFaceData2 2 2 User Manual R
18. le the analysis result will be shown in a second EndFaceData2 2 2 User Manual Rev 1 2 5 2 Capture Image by Loading Video File Click the Load Video button and a window will show up to allow selecting the video file and then capturing Snap Shot the reguired frame for analysis FZ image Analysis EBR File Options Help Load Video FZ Open Video File USB CAM Video Fie Total Record 14 E Video Oe P EI File name MPEGO037 AVI v etwork Files of type Video Files AVI v ff My N FZ Open Video File Seles Video File JReNVSM3EDASVideoNMPEGUD7 AVI fiber End Face When a nice image appears simply click the Snap Shot button to capture the image the analysis result will be shown in a second EndFaceData2 2 2 User Manual Rev 1 2 5 3 Capture Image Real Time from USB Camera Click the USB CAM button on the Image Analysis screen the Capture from Camera screen will show up together with the Fiber End Face screen FZ image Analysis E OJK Fie Options Help Load Video USB CAM Total Record 14 Capture from Camera Camera Ma 1 L Fiber End Face Enter the Fiber Id and click the Snap Shot button to capture the image on screen The Fiber Id can be entered manually as well as by a barcode scanner Many models of barcode scanner will also send an enter character at the end of sendi
19. lt records Image Data C NMEndFacelmageVWX X0 2 001 6 FIA Com pany Eternal Science Location Cable ID Job d Fibers From To Technician Date Time 2011 10 14 v 13 18 21 Notes images from YSMAKU Fiber Face Image Analysis Batch summary Report Pass Date Time MPEG UUUZ PNG 11 10 14 13 HPEGOUOS PNG 11710714 13 HPEGOUO PNG 11 10 14 13 MPEG UUUS PNG 11710714 13 MPEGO029 165 PNG 11 10 14 13 HPEGUD28 328 PNG 11710714 13 HPEGOO29 99 PNG 11710717 MPEGUD28 48 PNG 11210217 MPEGOO029 73 PNG JA SED De MPEGUD28 53 PNG 11 10 17 MPEGUD28 48 PNG 1110717 MPEGUDZ8 48 PNG 11 10 17 EndFaceData2 2 2 User Manual Rev 1 3 2 6 Print Preview ES Print preview SP EPOD ES EH s Flbar Fa mas nalis Batch Fapart ONDE Etamal Sol aca Last qn Gabla 10 Jah B Fillers From Ta Tani alan Wty Tim z li Im id 13 Hata laga Tram VAM mga Fila H ng Dafa sta zd MEERE Luk o ila EndFaceData2 2 2 User Manual Rev 1 3 2 7 Analysis Result Record Discard amp Wire Id Edit Total Record 14 h Record H Fiber Id e Goto wire Id Result Record Record Discard Any unwanted result record can be deleted from the batch by first calling up the record then press the Discard button Notes for hidden discarded image files Discarded records and images will no longer show up in any report or screen review However the imag
20. ng the barcode numbers That will trigger the Snap Shot button automatically If not simply click the Snap Shot key M F EF Capture from Camera Lok Camera No 1 Fiber ID 2100010036827 EndFaceData2 2 2 User Manual Rev 1 2 6 Analysis Result Upon capturing the image from either source the analysis will start and complete in a second The following result screens will be shown 2 Image Analysis 1 X Image Data C EFD Factory QC09 1001 FIA Options Image File Name Defects Pass Date Time 18 2100010036827 110903 095036 PNG 0 Pass 11 09 03 I Wire Diameter Defects Size Count Limit Count Pass ann nnn nr nn nr nnn nnn een lee Mea Laju lu Zone Total Record 18 Record t Fiber Id 2100010036827 Wield Copy to B2 Copy Alldto B2 Move H to Move All to 62 MESE Red Spot 4 2uM nea T Aw el nnmanf t MN I NCC I CVCIO p ment CO LU QE ucl nis Tirai Cain Shenzhen Eternal Scie EndFaceData2 2 2 User Manual Rev 1 3 Analysis Result Management 3 1 Major Terms and Concepts 3 1 1 Report Batch All related analysis results are stored in a collection called a batch A batch consists of a text file with extension FIA and a directory with extension EFD The directory contains all the original end face images and the fully markup images showing the analysis resul
21. p D 1500uM gt 10uH lt B 1 0 Contact us Email gary szetn com Face Book gary szetn com Company website http en szetn com Eternal International Company A division of Shenzhen Eternal Science Development Co Ltd
22. t the defects the four zone circles the cross hair rulers and a scale ruler at the corner EndFaceData2 2 2 User Manual Rev 1 3 1 2 Fiber Id amp End Face Image File Name Fiber Id User can define unigue Fiber Id for each piece of fiber end face This can be abar code label attached to the end face Image File Name When the image source is captured real time from an attached fiberscope the user can manually enter or scan the Fiber s Id and used it to form the end face image Tile name in the format nnnnnnnnn Y YMMDD HHMNSS PNG where nnnnnnnmn is the Fiber Id Y YMMDD is the date of capture and HHMNSS is the time of capture e g 2100010036827 110830 164102 PNG The end face image file name thus can both uniquely identify the fiber end face and the particular capture of the end face image Screens Accepting Barcode Fiber Id Capture from Camera e Capture from Camera PEE TT VILI Al Fiber ID 2100010036827 U T Nu n Snap Shot 2100010036827 Go to Fiber ID e Image Analysis Cok Fie Options Help Load Video USB CAM Total Record 16 Record t All 2100010036827 EndFaceData2 2 2 User Manual Rev 1 3 1 3 Analysis Result Record amp Result Record Identification Each instance of analysis will give out an analysis result record that consists of a text block of quantitative result with a fully marked up end face image thumbnail Image Data C EFD Factor
23. ticular result record either by Specifying the record number and go to it directly or Going to the next record sequentially or Going to the previous record sequentially or Searching by Fiber Id e Image Analysis Sele File Options Help Total Record 14 a J2 Record x Result Record Fiber d MPEGOOOS Navigation Lee gt Goto Fiber ID EndFaceData2 2 2 User Manual Rev 1 3 2 3 Searching by Fiber ID In the case of searching by Fiber Id if multiple result records exist in the batch each record will be found in turn for each press of the Search button a Image Analysis SERI File Options Help You can go directly to any record by specifying the Record Number Or the Total Record 18 Record tt 18 2100010036027 S CD Gan M MM 18 Fiber Id Bar code Scanner supported NA MNNN Imagje Data C EFD Fatory QC09 1001 FIA Hire Inmagg File Name Defects Pass Date Time 18 18 2100010036827 110903 095036 PNG 0 Pass 11 09 03 Zone Diameter Defects Size Count Limit Count Pass T 82 gt u ee O Pass A bbull gt bul lt 0 D Pass one B 120uM gt 2uM 6 be 0 Pass cl Red Spot A gt 2uM B 120uM gt Sul lt 0 Pass C 130uM 88uM 99 0 Pass D 250uM gt 10uM lt D 0 mes _ NNNM EndFaceData2 2 2 User Manual Rev 1 3 2 4 Result Image Views Result Image Views Spots Zones
24. when a new batch is created its batch header will be automatically entered the default company name and logo To setup the default company name and logo go to the Image Analysis screen click Options Set Company amp Logo the following screen will be shown FZ Set Default Company Name and Logo Company ETERNAL SCIENCE ee A 2 Supported Fiber Scope Models Currently the following fiber scope models from Eternal Science are supported A 3 Defined Fiber Profiles A 3 1 SM Fiber IPC 8497 1 for Single Mode Fiber 125um diameter EndFaceData2 2 2 User Manual Rev 1 SM Fiber IP C 8437 1 fone Diameter Defects Size Limit Defects Count Limit 25uM gt Zuk lt B 12 Luk gt zuk amp B B 1 2 uM Ful amp C 130uM 248uH amp d3 D 2 5l uM s1 DuM amp A 3 2 MM Fiber IPC 8497 1 for Multi Mode Fiber 125um diameter MM Fiber IP C 8437 1 EndFaceData2 2 2 User Manual Rev 1 A 3 3 SM 125um Fiber 250um Zone D for Single Mode Fiber sM 125um Fiber 5lum Zone D fone Diameter Defects Size Limit Defects Count Limit A 25uM gt Zuk lt B 120 uM gt uM amp 5 B 1 20 uM gt Ful lt D C 1380 uM 1DuM D z5DuM IDuM amp A 3 4 SM 125um Fiber 1 25mm Zone D for Single Mode Fiber SM 125um Fiber 1 25mm Zone D fone Diameter Defects Size Limit Defects Count Limit A 25uM 2UM amp B 1 20 uM gt 2UM amp B B 120 uM gt Gul amp C 1380 uM S1 DuM am
25. y QCO9 1001 FIA Hire Image File Name Defects Pass Date Time la z100010035827 110803 085035 PNG Zone Diameter Defects Size Count Limit Count Pass hhuM 1 rrr 3 3 P EE n maan Scu pucr Ke e SS ero uM Mari aa 1 An end face image file can be analyzed for multiple times e g each time with a different Fiber Profile selected each time gives out its own analysis result record In the text block of the result record it contains the date and time of the analysis which can be used to uniquely identity the particular analysis record EndFaceData2 2 2 User Manual Rev 1 3 2 3 2 1 Analysis Result Filing Reviewing and Compilation Analysis Result Filing All related analysis result records are saved in a collection called a batch A batch consists of a text file with extension FIA and a directory with extension EFD Batch name consists of a four character Batch Prefix followed by the second part which can be a sequence number or any meaningful short text string e g CUO1 0001 FIA CU01 0002 FIA CUOI BEIJING 110930 FTA Upon installation the default working directory is C EndFaceImage However user can use other directories or even create more new directories for EndFaceData to use EndFaceData2 2 2 User Manual Rev 1 3 2 2 Analysis Result Reviewing and Result Record Navigation A batch can be open to review the analysis result record User can call up a par
26. ysis Result Record amp Result Record Identification 16 3 2 Analysis Result Filing Reviewing and Compilation 17 3 2 1 Analysis Result ln Sa ma sae stan oa aan 17 2 2 2 Analysis Result Reviewing and Result Record Navigation 18 202 SOM CM by eilore Dada ulasan 19 3 24 Resule DEI e VON So an ae E 20 3 2 FR SUE Datt VION cect om maa asa lada 21 3 2 6 lagi uiii ra cree E NN A E A PAI n 23 3 2 7 Analysis Result Record Discard amp Wire Id Edit 24 3 2 8 Analysis Result Compilation 222 isiiscsccrsrisistssnasdsrssansssna sbunaaananda av rnnusnur 25 3 3 Analysis Result Reporting and Distribution oo XX 21 3 3 1 Hard Copies of Batch Reports Simplest Way of Distribution 21 3 3 2 Soft Copies of Press Quality Batch Reports in PDF Format Files 28 3 3 3 Sophisticated Report Viewing by Distributing Result Batch Files 28 4 License Dongle and Reader Mode o oooooo ooo Woman 20 4 IE Tesi BONUM cm 20 4 2 hindi rT P 30 EndFaceData2 2 2 User Manual Rev 1 35 Usage Tips metan l na S anis 32 5 1 NOW Bare TIROL 32 5 1 1 Bare te a IMUNU E UUEUUUE 22 5 1 2 Quick Batch Creation with Batch Serial Number 33 5 1 3 Meaninetul Text tor Batch Name o oo oocoooocccmusaskesn 33 MEE OR Dir etos aa ea ET 34 5 2 1 edge Other DI CO al UT 34 2