1. Technical Note Regarding Usage of Manual Input of PRV Area AFFTAC 4 00 Beta 07 Patch 01 November 25 2013 Scott R Runnels Ph D If you choose to input the area of a PRV manually it will override the area computed internally by AFFTAC and in so doing override part of the Vapor Flow Test Data that you specify for the PRV Below is an explanation for why that is the case There are two key flow models in AFFTAC for the PRV the choked vapor flow model and the two phase liquid flow model Since PRVs have historically been tested and specified for vapor flow it is that test data that has historically provided the inputs for AFFTAC to describe the PRV Specifically if a PRV is tested for vapor flow at a given pressure AFFTAC uses the following to describe the flow characteristics of the PRV It is referred to here as the Vapor Flow Test Data Vapor Flow Test Data 1 The pressure at which the test was performed standard temperature is assumed 2 The volumetric flow rate of air at that pressure 3 The coefficient of vapor discharge which is used to scale the choked flow model so that it matches the experimental data The equation below is the choked vapor flow model that AFFTAC uses during the simulation of the fire event y 1 E w 144C A P 2 ij ZRT y 1 where w mass flow rate lbs sec A minimum cross sectional area of the valve ft P upstream gas pressure psia T upstream gas temperature a
2. bsolute deg R g gravitational constant ft sec constant R gas constant equal to 1 545 molecular weight ft deg R constant Coy valve discharge coefficient user input Z gas compressibility factor user input y ratio of specific heats user input During the simulation pressure and temperature are known and mass flow rate is sought The one value that is not typically known by the user is the area and so AFFTAC computes it using the same equation above but while inserting the Vapor Flow Test Data to provide values for some of the variables Specifically the equation above is rearranged to solve for area WvaporFlow Test Data AS y y gy D 144C py PaporFlowTest Data ZRT F il VaporFlow Test Data Once the value for area is known it can be used in the two phase liquid flow model as well The key point is In all flow calculations the same value of area is used Therefore overriding AFFTAC s area estimator above with manual input also affects the vapor flow model In fact it overrides the role of the Vapor Flow Test Data in the equation above That stated if exactly the same value for area as would be computed above is specified manually the computations will work out the same So if you want to specify the area manually and also ensure the PRV model honors the Vapor Flow Test Data you must calculate the area by hand using the equation above and enter that value If you choose to do tha
3. t please refer to the User s Manual which provides a detailed discussion of the units There is one minor rather obscure heuristic in AFFTAC that is based on the volumetric flow rate data Because of that the GUI does not disable the PRV volumetric flow rate data when you choose to enter the area manually However for reasons described here it is essentially ignored when the area is entered manually
Download Pdf Manuals
Related Search
Related Contents
Massive Studio Table lamp 66606/93/10 Integral 8GB DDR3-1333 マイク付きイヤホン+イヤホンケーブル巻取りホルダー取扱説明書 MODÈLES - General & General International TP-Link TL-POE10R V3 Quick Installation Guide Whirlpool MT0060XB User's Manual Samsung KFR-25G/SWA 用户手册 0E-211 PLÁSTICO PROFESIONAL 2G TAP User Manual Copyright © All rights reserved.
Failed to retrieve file