1. y DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support 2datasphere eu 75 DATASPHERE DWRN171 XX User Manual more than distribution File Edit Setup Control Window Help e set wlan ssid rovingi A set wlan pass rubygirl 2 23 save Storing in config 2 23 reboot Reboot iFly Uer 2 23 84 26 2011 on 131G11 AC fiddr 88 06 66 14 5e d7 lease 128s ON 192 168 2 66 2008 2255 255 255 80 192 168 2 1 Listen on 28808 In this example the ip address and the port of the web server is 192 168 2 66 2000 Test of Web Server OEM To test the Web Server OEM you open a web browser and type 192 168 2 66 2000 A web page like in figure 2 is shown Figure 2 Web Server Home page DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 76 E DATASPHERE DWRN171 XX User Manual more than distribution e gt cO WEB SERVER OEM v2 0 OUTI OUT2 OUT3 OUT4 ON OFF 9 ON OFF 9 ON OFF ON OFF 9 SENSI SENS2 SENS3 SENS4 856 0000 407 0000 407 0000 353 0000 Commands and Setting OEM web server The Web Server OEM returns HTTP or XML response By default and if it is not specified the web server returns HTTP response If istyped 192 168 2 66 2000 without GET parameter
2. DATASPH ERE DWRN171 XX User Manual aera ca Figure 18 Scan Showing Access Points in WPS Active Mode eg x d COM3 Tera Term VT Edit File Setup Control Window Help um SSID Ch RSSI Sec MAC Address Suites 1 SensorNet i 52 WPA2PSK 08 22 3f 6b 95 42 AESM AES UPSPB 1104 2 Belkin 48E9 06 28 WPA2PSK 94 44 52 97 20 e9 AESM AES WPSPB A 1184 3 linksys 86 72 Open 88 1e e5 67 73 b1 WPSPB 104 4 default 86 75 Open 88 18 02 70 7e e8 WPSPB 2108 ADHOC NETWORKING MODE There are two types of networks infrastructure and ad hoc Infrastructure networks in which an access point links all Wi Fi devices are the most common The access point keeps track of devices on the local network and directs IP packets In many cases the access point is also a router and forwards packets from the local network to other networks and the Internet It is also very common for the access point to run a DHCP server which tracks and assigns IP addresses Ad hoc networks are point to point networks in that each Wi Fi device is linked directly to every other Wi Fi device on the ad hoc network There is no access point All Wi Fi devices on the ad hoc network participate in keeping the network alive and each keeps track of the other active devices on the network by sending and receiving beacon and probe packets In most cases IP addresses are assigned through automatic IP although one of the Wi Fi devices can be configured as a D
3. Example Set Up the Protocol amp Port Number set ip proto 1 Enable UDP as the protocol set ip host lt address gt Set the remote host s IP address set ip remote lt value gt Set the remote port on which the host listens set ip local lt value gt Set the port number on which the module listens save Save the settings in the configuration file reboot Reboot the module NOTE f you attempt to send data by typing characters on the keyboard or if your microcontroller is not sending data fast enough the module sends out packets with fewer data bytes To avoid this issue set the flush timer to a higher value By default it is set to 10 ms You can disable forwarding based on the flush timer set comm time 0 or set it to a higher value e g set comm time 2000 Because UDP is a connectionless protocol data begins flowing as soon as you reboot the module Unlike TCP you do not need to send an open command to establish the connection The module acts like a data pipe the UART data is sent over the Wi Fi link via the UDP protocol in this case and the data coming from the Wi Fi link via UDP protocol in this case is sent to the UART UDP Auto Pairing With the UDP auto pairing feature the module temporarily stores the host IP address of the first remote device that sends a UDP packet to the module This host IP address is stored in the module s RAM which is cleared when the module sleeps or power cycles This feature
4. Default lt need default Example need example amp desc set q power value This register automatically turns on the sensor power where value is shown in Table 4 This parameter sets an 8 bit register with two 4 bit nibbles If the top nibble is set power is applied upon power up and removed upon power down or sleep If the bottom nibble is set power is applied when a sampling event occurs such as e The UDP broadcast e The automatic web posting of sensor data e The power is removed immediately after sampling is complete Table 4 set q power Command Sensor Pin Voltage Settings Value Sensor pin voltage 0 Turn off the sensor power 1 GROUND the sensor pin 2 1 2V internal regulated reference 3 VBATT input pin 4 3 3V output of on board regulator DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 19 AN DATASPH ERE DWRN171 XX User Manual dpa Default lt need default Example set q power 0x20 Sets power to 1 2 V automatically upon power up set q power 0x02 Sets power to 1 2 V when a sampling event occurs set q power 0x40 Sets power to 3 3 V automatically upon power up set q power 0x04 Sets power to 3 3 V when a sampling event occurs set sys autoconn value This command sets the auto connect timer in TCP mode where value
5. Default 255 255 255 255 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 10 AN DATASPH ERE DWRN171 XX User Manual r AAR Example set broadcast address 255 255 255 255 Sets the broadcast address to 255 255 255 255 set broadcast interval lt mask gt This command sets the interval at which the hello heartbeat UDP message is sent and is specified in seconds The value is a mask that is ANDed with a free running seconds counter if the result is all Os a packet is sent For example e Ifthe interval is 0x1 the module sends one packet every 2 seconds e Ifthe interval is 0x2 The module sends two packets every 4 seconds e Ifthe interval is 0x3 the module sends one packet every 4 seconds e Ifthe interval is 0x6 the module sends two packets every 8 seconds e Ifthe interval is 0x7 the module sends one packet every 8 seconds The minimum interval value is 1 every 2 seconds and the maximum value is Oxff every 256 seconds Setting the interval value to zero disables UDP broadcast messages Default 7 Example set broadcast interval 6 Sets the heartbeat UDP message interval to 6 seconds set broadcast port value This commands sets the port to which the UDP hello heartbeat message is sent where value represents the port number Default 55555 Example set broadcast port 55555 Se
6. 7 GPIO7 Output Blue LED 8 GPIO8 Output Unused 9 GPIO9 Input Ad hoc mode and factory reset 10 GPIO10 Output UART TX 11 GPIO11 Input UART RX 12 GPIO12 Input Throttles the transmitter if hardware flow control is enabled Driving this pin low enables transmitter driving this pin high disables it 13 GPIO13 Output This pin goes high on power up and goes low when the system is ready If hardware flow control is enabled this pin toggles to high to indicate the RX buffer is full 14 GPIO14 Input Setting the Alternate GPIO Functions The GPIOA 6 default function is to control the LEDs You can override the default to allow user programmable I O or alternate I O functionality by using the set sys iofunc mask command where mask is entered as a hex number The hex value represents a bitmask that controls each bit in the mask and represents a particular GPIO pin If a bit is O then the corresponding GPIO pin is driven read by the firmware per the default function The I O function mask is encoded as shown in Table 20 Table 20 GPIO Pin Alternate Function Bitmask Bit Signal Name Direction Function 0 GPIO4 Output Disable the LED function so the I O can be used as a GPIO pin 1 GPIO5 Output Disable the LED function so the I O can be used as a GPIO pin 2 GPIO6 Output Disable the LED function so the I O can be used as a GPIO pin 3 Unused 4 GPIO4 Output This pin goes high af
7. Set the string to port open set comm remote lt string gt This command sets the ASCI string that is sent to the remote TCP client when the TCP port is opened where lt string gt is one or more characters up to a maximum of 32 If you do not wish to use a string use a zero 0 as the lt string gt parameter Default HELLO Example set comm remote welcome Set the string to welcome set comm idle value This command sets the idle timer value where value is a decimal number representing the seconds from 0 to need the max value The idle timer value is the number of seconds during which no data is transmitted or received over TCP before the connection is closed automatically Setting the timer to O the default means the module never disconnects when idle Default 0 Example set comm idle 25 Set the idle timer value to 25 s set comm match value do we want value for this one since it can be decimal or hex Or use value or hex This command sets match character where value is a decimal number from 0 to 127 or a hex number from 0 to 7F When this configuration option is set the module sends an IP packet each time the match character appears in the data You enter value either as the decimal e g 13 or hex e g Oxd equivalent of the of the ASCII character Setting the match character to 0 disables matching A match character is one of three available methods you can use to
8. Solutions GmbH All rights reserved www datasphere eu support datasphere eu 17 AN DATASPHERE DWRN171 XX User Manual more than distribution Figure 3 set ip tcp mode Command Bit Mapped Register 4 312 1 0 Shorten the TCP connect timer use with bit 1 Shorten the TCP connect timer use with bit 0 Forces the module to use DNS first to resolve the IP address even if the host IP is set Reserved Disables remote configuration for security purposes Default 0x0 Example set ip tcp mode 0x4 Forces the module to use DNS set ip tcp mode 0x10 Disables remote configuration set opt jointmr lt value gt This command sets the join timer which is the length of time in ms the join function waits for the access point to complete the association process lt value gt is a decimal number representing the number of ms This timer is also used as the timeout for the WPA handshaking process Default 1000 Example set opt jointmr 1050 Sets the join timer to 1 050 ms set opt format lt flag gt The command sets the HTTP client web server information where lt flag gt is a bit mapped register as shown in Figure 4 See Using the HTML Client Feature on page 54 for more details Figure 4 set opt format Command Bit Mapped Register 4 3 2 1 0 Automatically send an HTML header based broadcast interval Se
9. WEB SERVER OEM v2 0 OUTI OUT2 OUT3 OUT4 ON OFF 9 ON OFF 9 ON OFF ON OFF SENSI SENS2 SENS3 SENS4 856 0000 407 0000 407 0000 Submit In this web page there are 8 sections 4 sections to control the 4 outputs and 4 sections to read the values of the 4 sensors Clicking the radio button of OUT1 OUT2 OUT3 and OUT4 we can activate or deactivate the 4 outputs and clicking in the button Submit we send the request to webserver The webserver receive the request of the client to active or deactivate the outputs in the module and store the new STATE in the eprom memory data then read the 4 sensors input voltage and return the http response to client showing the new STATE of the outputs and sensors in the web page To customize the scale for the sensors input and title and all the parameters is possible to connect at the ip address of the webserver including all the parameters needed as reported in paragraph 5 For example 192 168 2 66 2000 title offt amp scale1 0 34 amp scale2 2 to hide the title set scale1 0 34 and scale2 2 all these configuration parameters are maintained in the webpage content of response after submit request al webserver DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 80 AN DATASPHERE DWRN171 XX User Manual more than distribution XML response webserv
10. amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 31 AN DATASPHERE DWRN171 XX User Manual more than distribution Example get time Show the time server information get wlan This command displays the SSID channel and other WLAN settings Example get wlan Show the WLAN settings get uart This command displays the UART settings Example get uart Show the UART settings ver The command displays the firmware version Example ver Show the firmware version STATUS COMMANDS These commands begin with the keyword show and they return the current values of the system variables In some cases e g IP addresses the current values are received from the network and may not match the stored values Except where noted the show commands do not have any parameters show battery This command displays current battery voltage and is only applicable to datasphere battery powered products such as the RN 370 and temperature sensors ISENSOR CB Example show battery Show the current battery voltage show connection This command displays the connection status in the hex format 8 XYZ where 8 lt XYZ gt is a bit mapped register providing the information shown in Figure 6 lt not sure if this text explains enough gt Figure 6 show connection Command Bit Mapped Register 16 13 12 9 7 6 5 4 3 0 TCP status 0 idle 1 connected 3 No IP 4 conne
11. lt cr gt after the to enter command mode The module replies with CMD to indicate it is in command mode There is a 250 ms buffer before and after the escape sequence If characters are sent before or after the escape sequence within this 250 ms interval the DWRN171 XX module treats them as data and passes them over the TCP or UDP socket and the module will not enter command mode If you want to use different characters to enter command mode not you can set the character to use with the set comm char command Example Enter command mode close This command disconnects a TCP connection Example close Close the TCP connection exit This command exits command mode After leaving command mode the module responds with EXIT Example exit Leave command mode factory RESET This command loads the factory defaults into the module s RAM and writes the settings to the standard configuration file You must type the word RESET in capital letters After you type this command you must reboot the module for the settings to take effect Example factory RESET Reset the configuration settings to the factory defaults join string This commands instructs the WFly module to join the network indicated by string If the network has security enabled you must first set the pass phrase with the set wlan pass command prior to issuing the join command NOTE The string must not contain spaces If the netw
12. support datasphere eu ES AN DATASPHERE DWRN171 XX User Manual more than distribution NOTE The automatically assigned IP address must be on the 169 254 x y subnet otherwise the DWRN171 XX module will not be accessible If your computer has both wireless and wired interface hardware you may need to disable the wired LAN interface hardware before connecting to the ad hoc network If the wired LAN is enabled the computer may assign an IP address that is not on the same subnet as the DWRN171 XX module Once connected with an appropriate IP address telnet into the DWRN171 XX module on port 2000 using the following command telnet 169 254 1 1 2000 The module issues the response HELLO You can now enter command mode using the escape sequence and configure the module In firmware versions 2 28 and higher you can disable remote configuration e g for security To disable remote configuration use bit 4 in the TCP mode register by issuing the command set ip tcp mode 0x10 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 8 AN DATASPHERE DWRN171 XX User Manual more than distribution COMMAND REFERENCE datasphere DWRN171 XX modules support a variety of commands for configuration This section describes these commands in detail and provides examples COMMAND SYNTAX To issue command
13. value is one of the options shown in Table 11 The module uses this policy on powers up including waking up from the sleep timer Table 11 set wlan join Command Options Value Policy 0 Manual Do not try to associate with a network automatically 1 Try to associate with the access point that matches the stored SSID passkey and channel If the channel is set to O the module will scan for the access point Default DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 27 AN run m rr DWRN171 XX User Manual i biii 2 Associate with ANY access point that has security matching the stored authentication mode The module ignores the stored SSID and searches for the access point with the strongest signal You can limit the channels that are searched by setting the channel mask 3 Reserved 4 Create an ad hoc network using stored SSID IP address and netmask You MUST set the channel Unless another ad hoc device can act as DHCP server set DHCP to 0 static IP or use automatic IP You can use this policy instead of the hardware jumper to create a custom ad hoc network Default 1 Example set wlan join 4 Create an ad hoc network set wlan hide lt value gt This command hides the WEP key and WPA passphrase where lt value gt is 0 or 1 If this paramet
14. EE DEPTH ei Eds 34 File 1 0 CoMmMa Tao w cccescessssessssessssesscsesscsesscsessssesscsesssssscsesussesucscsussesscsesvssesscsesussesucscsvesesecsesucsesscsesucscsucsesucaesscssscaesecscsecaeseeaeseeaeseesess 36 Advanced Features amp Settings ccssssessssssssssssssssssssssssnscessnssesasssssaneesenssesesssesanesseuseesenssesasssssnsesssnssssasssee DC Putting the Module to Sleep amp Waking Ito csesesssssssessssessssessssessesessssessssessssessssesussesussessssesussesussesussesussesussesusseseaessseensaeensaees 38 System amp Q Auto Cohinect TIMENS sseste scessccievessiecorssedsdetoiesercastotasensiotoievedsdetevadesedenotedensastotauersisbetevededetorasededetocedeseastojasessdebeseveniaveerae 39 UDP Sleep amp Connection Timers eccsssssssesssssssssssssssssssssssssssssscssssssesssssssssssscsessssssscssssssssecassncassecsesneassucassscassacassscassecaseneasseeaees 40 MGR GO MMe CHOR TIIBES oer Rm Ha Unite mentum imm mdr E 40 Opening a Ee Reese dl p 40 Closing the TCP Connection treten tente tete tente tete tente Enst ENANA nE SEEEN EEES EEES te tete tete te toten te sauf 41 Wake on Sensor Nolo ERR 41 Wake on UART ACEVIEV ii eati e PR ORE EEUU ER E RUE ERE RUE Eade REHEREERUEEEREen 41 UART Receiver amp RTS CTS Hardware Flow Control ettet tntntete tette tete tnte tete teens t tese naE 42 Setting GPIO Direction Alternate Functions amp Dis
15. Example set sys trigger lt need example gt The module wakes up when lt insert desc gt set sys value lt mask gt This command sets the default value of the GPIO pins outputs upon power up where lt mask gt is a hex number representing a bit mapped register The GPIO pins that are configured as outputs can be driven high or low on power up or when the module wakes from sleep The default power up states can be set ONLY for the GPIO pins that are set as outputs Setting the value to 1 makes the default power up state high setting the value to 0 makes the default power up state low To configure GPIO pins as outputs use the set sys mask lt value gt command NOTE GPIO pins 4 5 and 6 are used by the firmware to blink the status LEDs To set the default power up states for these GPIO pins you must first disable their use by the firmware using the set sys iofunc 0x7 command Default 0x0 Example To configure power up states of GPIO8 output by default set sys value 0x0100 Sets GPIO8 high upon power up set sys value 0x0000 Sets GPIO8 low upon power up set sys wake lt value gt This command sets the automatic wake timer where value is a decimal number representing the number of seconds after which the module wakes from sleep from 0 to y get max Setting value to 0 disables See System Timers amp Auto Connect Timers on pagex for more details update ref Default 0 Example set sys w
16. Mbyte ROM 2 Kbyte battery backed memory o 10 general purpose digital I O pins o 8analog inputs 14 bits 400 mV o UART 1 Mbps host data rate and SPI slave 2 Mbps host data rate hardware interfaces o Real time clock for wakeup and time stamping data logging auto sleep and auto wakeup modes e Network support o Supports ad hoc and infrastructure mode connections Push button WPS mode for easy network configuration On board TCP IP stack Over the air firmware upgrade FTP and data file upload support Secure Wi Fi authentication via WEP 128 WPA PSK TKIP and WPA2 PSK AES Configuration over UART or wireless interfaces using simple ASCII commands Built in networking applications DHCP client DNS client ARP ICMP ping FTP TELNET HTTP UDP and TCP Web Server OEM v2 0 only DW RN 171 XCW O O O O O O O CONFIGURATION The DWRN171 XX module operates in two modes data mode and command mode In data mode the module can accept incoming connections or initiate outgoing connections To configure parameters and or view the current configuration you must put the module into command mode also called configuration mode The DWRN171 XCW includes also a web server OEM v2 0 to know the features and configurations looks at the Appendix A DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu Sbs AN DATASPHERE DWRN
17. RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu Ag AN DATASPHERE DWRN171 XX User Manual more than distribution ADVANCED APPLICATIONS This section describes a variety of advanced applications for the DWRN171 XX module such as sending data using UDP associating with access points using the HTML client feature upgrading the firmware over FTP etc SENDING DATA USING UDP UDP is a connectionless protocol there is no initial handshaking between the hosts to set up the UDP connection and the receiver does not send an acknowledgement when it receives UDP packets Therefore UDP is an unreliable protocol because there is no guarantee that the data will be delivered correctly However because it is connectionless UDP is suited for applications that cannot tolerate too much latency but can tolerate some errors in the data e g video transmission To use UDP with the module you must enable the UDP protocol using the set ip proto 1 command You must also specify the remote host s IP address and the local and remote port number that you will use for UDP communications The following example shows the commands you use to enable UDP data transfer Example Associate with a Network set wlan ssid lt string gt Set the network name set wlan phrase lt string gt Set the passphrase for WPA and WPA2 modes
18. You can confirm that the device has properly associated with the ad hoc network using the ping keyword ping 169 254 1 1 10 You can associate with the ad hoc network from a computer by specifying the network name and password if required in the operating system For example choose Control Panel gt Networking and Sharing gt Networking and Sharing Center Windows Vista or Control Panel gt Network Connections Windows XP You can then view available networks and select the name of the DWRN171 XX ad hoc network NOTE Once associated with the ad hoc network Windows Vista may require a few minutes to allocate an IP address To work around this issue assign a static IP address under Network Settings gt TCP IP gt Properties Once your computer is associated with the ad hoc network you can use the module s IP address to open a connection or connect using telnet as you would with an enterprise connection Scanning for Access Points in Ad Hoc Mode The module supports ad hoc and infrastructure network modes but not simultaneously Scanning for wireless networks is a function of infrastructure mode Therefore the module disables ad hoc mode before scanning With firmware version 2 22 and higher the module can scan for networks while in ad hoc mode Issuing the scan command temporarily disables ad hoc model while the module is scanning Ad hoc mode is restored automatically when the scan completes If you are connected to the module ov
19. and data transfer timers and matching characters dns Sets the DNS host and domain ftp Sets the FTP host address and login information ip Specifies the IP settings option Supports optional and infrequently used parameters sys Sets system settings such as sleep and wake timers time Sets the timer server settings uart Specifies the serial port settings such as baud rate and parity wlan Sets the wireless interface settings such as SSID channel and security options set adhoc beacon lt value gt This command sets the ad hoc beacon interval in milliseconds where value is a decimal number from 0 to 65 436 Default 100 Example set adhoc beacon 120 Beacons are sent every 120 ms set adhoc probe lt value gt This command sets the ad hoc probe timeout in seconds where lt value gt is the number of seconds from 0 to lt add max gt The probe timeout is the number of seconds the module waits for probe responses before declaring ADHOC is lost and disabling the network interface Default 5 lt changed to 5 from 60 per the default config settings in section 19 gt Example set adhoc probe 80 Sets the ad hoc probe timeout to 80 s set broadcast address lt address gt This command sets the address to which the UDP hello heartbeat message is sent where lt address gt is an IP address in the form lt value gt lt value gt lt value gt lt value gt with value being a number between 0 and 255
20. are not authorized for use in safety critical applications such as life support where a failure of the datasphere product would reasonably be expected to cause severe personal injury or death unless officers of the parties have executed an agreement specifically governing such use DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 86
21. control TCP IP packet forwarding The other methods are set comm size and set comm time For more information refer to UART Receiver amp RTS CTS Hardware Flow Control UART Receiver on page 42 Default 0 Example set comm match 13 Set the match character to a carriage return set comm size value This commands sets the flush size in bytes where value is a decimal number from 0 to 1 420 at 9600 baud When this configuration option is set the module sends an IP packet each time value bytes are received datasphere recommends that you set this value as large as possible to maximize TCP IP performance NOTE To optimize the link this value is set automatically when the baud rate is set It is assumed that higher baud rates equate to more data hence the flush size is increased Flush size is one of three available methods you can use to control TCP IP packet forwarding The other methods are set comm match and set comm time For more information refer to UART Receiver amp RTS CTS Hardware Flow Control UART Receiver on page 42 Default 64 Example set comm size 1420 Set the flush size to 1 420 bytes DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 212 AN DATASPHERE DWRN171 XX User Manual more than distribution set comm time lt value gt This command sets the flush time
22. gt is the host name for which to search Example lookup roving1 Search for the host roving1 open lt address gt lt value gt This command opens a TCP connection to address where value is the port number and address is an IP address in the form lt value gt lt value gt lt value gt lt value gt with value being a number between 0 and 255 If you do not use the address and value parameters the module attempts to connect to the stored remote host IP address and remote port number address can also be a DNS host name that the module attempts to resolve Default Stored remote IP address and port Example open 10 20 20 62 2000 Open a connection to 10 20 20 62 port 2000 ping string value This command pings a remote host where string is one of the parameters shown in Table 13 and value is the number of pings to send By default the module sends 1 packet The optional value sends value pings at 10 per second Table 13 ping Command Parameter Options Option Description g This option pings the gateway The gateway IP address is loaded if DHCP is turned on otherwise you must set it using the set ip gateway lt address gt command h This option pings the stored host IP address You can set the host IP address using the set ip host lt address gt command i This option pings a known Internet server www neelum com by first resolving the URL This option is use
23. input O 1 Trigger sensor input 1 2 Trigger sensor input 2 3 Trigger sensor input 3 4 Enable WPS function 5 Enable sleep on GPIO8 Table 8 describes how you can wake the module using sensor input Table 8 Sensor Input Trigger Values Wake on Sensor Input Value Command 0 1 set sys trigger 1 1 2 set sys trigger 2 2 4 set sys trigger 4 3 8 set sys trigger 8 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 22 AN DATASPHERE DWRN171 XX User Manual more than distribution NOTE Setting the system trigger value to 0x10 enables WPS functionality WPS is disabled by default Setting the trigger value to 0x20 i e using lt mask gt puts the module to sleep when GPIO8 is pulled high To enable this feature use the set sys trigger 0x20 command This command makes GPIO8 an interrupt pin and puts the module to sleep as soon as it is pulled high regardless of the module s state the module goes to sleep even if it is associating with a network or has an open active TCP connection This command is useful for when the module is failing to associate with network because it is out of range or for any other reason or if the module must be put to sleep quickly NOTE GPIO8 must be low on power up and stay low until you want to put the module to sleep Default 0x1
24. is a decimal number from 0 to 255 as shown in Table 5 Setting this parameter causes the module to connect to the stored remote host periodically as specified by value NOTE To use the auto connect timer you must store the remote host s IP address and port in the DWRN171 XX module using the set ip host address and set ip remote value commands Table 5 Auto Connect Timer Settings Value Description 0 Disable the auto connect timer default 1 Connect to the stored remote host IMMEDIATELY upon power up or when waking from sleep 2 254 Connect to a stored remote host every value seconds 255 Connect to a stored host IMMEDIATELY upon power up or when waking from sleep and go back to sleep IMMEDIATELY as soon as the TCP connection closes Default 0 Example set sys autoconn 5 The module connects to the host every 5 seconds set sys autosleep value This command sets the auto sleep timer in UDP mode where value is a decimal number from 0 to xx lt need max If the protocol is set to UDP ONLY this timer acts as a quick sleep function The module sleeps value ms after transmission of the first UDP packet Setting value to 0 disables the auto sleep timer Default 0 Example set sys autosleep 2 Sets the timer to sleep after 2 ms set sys iofunc mask This command sets the I O port alternate functions where mask is a hex number referring to a bit mapped r
25. packets of data it sends out many packets of small MTU size To avoid this issue set the flush timer to a higher value e g set comm time 5000 By default it is set to 10 ms DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 55 AN DATASPH ERE DWRN171 XX User Manual AE Example Connect to Web Server when UART Data Is Received set ip proto 18 Turn on HTTP mode 0x10 and TCP mode 0x2 set dns name www webserver com Set the web server name set ip host 0 Turn on DNS set ip remote 80 Set the web server port 80 is standard set com remote GETS userprog php DATA Sample server application set uart mode 2 Automatically connect using data trigger mode When the serial UART data comes in the module automatically connects to the web server and sends GET userprog php DATA users serial data n n Post Binary Data Web servers expect ASCII data If the user data is binary the module can convert it to ASCII format before sending it to the web server Example Convert Data from Binary to ASCII set ip proto 18 Turn on HTTP mode 0x10 and TCP mode 0x2 set dns name www webserver com Set the web server name set ip host 0 Turn on DNS set ip remote 80 Set the web server port 80 is standard set com remote GETS userprog php DATA Sample server application set optio
26. pane 67 COMM PARAMETERS erect ERR EIERE R HEN RIENE LUIS E DERE rt tete cce eed 67 alg c 68 leporum M 68 OPTIONAL PARAMETERS israse EEUU IER 68 SYSTEM PARAMETERS EM 69 TIMESERVER PARAMIJTERS neenon sette eroe rhet E E E T EOR 69 UART PARAMETERS a E N N Lo tue ed edd 69 WLAN inus icc Y 69 Restoring Default Configuration Settings cccccsesssssssssesssssssssesessscssesssecsssessssessssessssessssessssesnssessssesussesusssenssesessessaesesseensaeseeaees 70 Boot up Timing VATDBS cu cian cnr ci ene RE i Lan ias ern i Fn rr E Cun e opc caen e ca d ais M Supported Access so 2 GARRETT Known Problems Locas ada suite ene eee eee Caen ne nn een een tecta rece d AppendiK A T RN A USER MANUAL WEB SERVER OEM V2 0 csssssssssesesesesesesesescscscsescsesesesesesssesesesesesenesesesesesesesesesesesesesssssesseseseseseseaeaeseaeaeaeaeeeeeeeeenees 74 Basic Configuration of RN 171 for WEB SERVER OEM ccccccsccsssscssesessssessesessssessescsscscssesesscsessesessesessesescsessescseescseesesseaeseesess 74 Associate with a Secure netWOFK cae teeth se rete es e Eee Ete HERE E REPRE ER ER EE REVENUE ee SH AYER Ee YEAH ERE 75 ueri 76 Commands and Setting OEM web server csccccsssssssssssssssss
27. pin as the threshold is about 500 mV You can use additional pull up to 1 2 V DC if the circuit has an impedance due to leakage current of less than 5 Mohms 500 mv 100nA Leave unused SENSEO to 3 pins disconnected WAKE ON UART ACTIVITY When the module is in sleep mode the UART is disabled However the module can wake on UART activity by connecting the sensor pins to the RX data or CTS pin using the appropriate divider resistors as described in Wake on Sensor Input on page 41 The DWRN171 XX evaluation board has a built in resistor divider connecting SENSEO and SENSE1 to RXD and CTS respectively This setup allows wake on RX and CTS using a 3 3 V signal NOTE Do not apply 3 3 V directly to SENSEO and SENSE1 the voltage on any sensor input CANNOT exceed 1 2 V DC or the module will be permanently damaged To enable wake on RXD use the set sys trig 1 command DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 41 AN DATASPHERE DWRN171 XX User Manual more than distribution It should be noted that the first or possibly multiple byte sent to the module will likely be lost therefore you should take care to send a preamble byte to wake the module before sending valid data bytes Alternatively use the CTS input to wake the module and wait until it is ready to accept data To enable this setting
28. q sensor Oxff The module samples all 8 sensor channels set sys auto 30 Connect every 30 seconds set option format 7 Send the header plus the sampled binary data converted to ASCII format The resulting string sent to the server is DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 56 AN DATASPHERE more than distribution DWRN171 XX User Manual GET userprog php DATA 0F3000001111222233334444555566667777 n n The data format for this example is oe Channel 0 Channel 1 Channel 2 Channel 3 Channel 4 Channel 5 Channel 6 Channel 7 OF30 0000 1111 2222 3333 4444 5555 6666 7777 HTML Client Example Posting Sensor Data Automatically In this example the module connects to the web server at www rovingnetworks com server php value and posts the sensor data to the web server every 60 seconds You set the network connections as described previously and set additional parameters set ip proto 18 Turn on HTTP mode 0x10 and TCP mode Ox2set dns name www rovingnetworks com Set the web server name set ip host 0 Turn on DNS set ip remote 80 Set the web server port 80 is standard set com remote GETS server php value Set up the server application string set sys auto 10 Automatically connect every 10 seconds set option format 7 Send the header and sampled binary data c
29. the UART GET ob php obvar WEATHER n n Where the n is the linefeed character decimal 10 or hex Oxa Two linefeeds are required for the web server to know the page is complete NOTE Some web servers require a carriage return and linefeed to indication the page is complete In this case use r n at the end of the string instead of n n Built In HTML Client Modes You can set up the module to post data to and get data from a web server automatically without an external host CPU You enable these advanced web features using the set option format lt flag gt command where lt flag gt represents a bit mapped register Refer to the set opt format lt flag gt command on page 18 for the bit function descriptions Table 22 describes the wake reason values DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 54 AN crum eae DWRN171 XX User Manual i rae Table 22 Wake Reason Values Value Wake Reason 0 Undefined 1 Power on or hardware reset battery install or power up 2 Sleep wake when the sleep timer is expired 3 Sensor 4 Undefined 5 Button RN 370 serial adapter only 6 Software reboot 7 Watchdog Example HTML Client Modes set option format 1 Automatically send an HTML data header set option format 7 Append sensor data in ASCI
30. use the set sys trig 2 command NOTE On the RN 134 evaluation board revision 2 the resistor pack connecting the RX and CTS signals is not correctly connected to the sensors To wake on UART RX place a jumper from pin 3 on the evaluation board header to pin 2 on the sensor header To wake on UART CTS place a jumper from pin 10 on the evaluation board header to pin 3 on the sensor header UART Receiver amp RTS CTS Hardware Flow Control The UART receive buffer is approximately 1 500 bytes At lower baud rates less than 115 K the system can send data over TCP IP without flow control Depending on the frequency and quantity of the data being sent the comm parameters optimize Wi Fi performance by specifying when the system sends IP packets To minimize latency and TCP IP overhead use the flush size or match character to send data in a single IP packet In most cases you should set the flush timer to a large number to avoid fragmentation For high throughput increase the UART baud rate set the flush size to 1 460 and set the flush timer to a large value so that full IP packets are sent You can control packet forwarding in the following ways e set comm match value sets the value of the packet terminator Each time the module sees the match character it sends an IP packet For example set comm match Oxd forwards a packet when the module sees a Oxd hex character e setcomm size value sets the flush size where value is the nu
31. value from the console where value is a decimal number in seconds from x to y get min and max The RTC ticks at 32 768 Hz Default lt is there a default Example set time raw 1 Need desc set uart baud value This command sets the UART baud rate where value is 2400 4800 9600 19200 38400 57600 115200 230400 460800 or 921600 NOTE The RN 134 evaluation board s RS 232 interface cannot exceed 230 400 baud Default 9600 Example set uart baud 19200 Sets the baud rate to 19 200 baud set uart instant value This command immediately changes the baud rate where value is 2400 4800 9600 19200 38400 57600 115200 230400 460800 or 921600 This command is useful when testing baud rate settings or when switching the baud rate on the fly while connected over TCP via Telnet Using this command does not affect configuration The module returns the AOK response and then the module exits command mode is this true with current version of firmware The note about ver2 2 says Now when this command is issued it returns an AOK over Telnet and does not exit command mode Is it only if you are connected via telnet that it stays in command mode NOTE In firmware version 2 22 and lower the module does NOT return an AOK over Telnet before exiting command mode If used in local mode the baud rate changes and the module sends AOK using the new baud rate if the host switches to the
32. when not connected To configure the module to connect using GPIO5 and GPIO6 use the following commands set ip host address Set the IP address of the remote host set ip remote value Set the IP port of the remote host set sys iofunc 0x70 Set alternate function for GPIO4 6 save Store configuration reboot Reboot the module After executing these commands run your application or other software on the remote host that opens and listens on the specified port Then connect GPIO5 to your embedded processor or other control signal When GPIOS is driven high the module attempts to connect When GPIO5 is driven low the connection is closed NOTE Do not to drive the GPIO pin with more than 3 3 V DC or permanent damage to the module will occur If the connection to the remote host is successful GPIO6 goes high If you have set the COMM OPEN and REMOTE strings the UART displays OPEN and the remote host displays HELLO Figure 9 Controlling Connections with the GPIO Pins shows the process of controlling connection with the GPIO pins Figure 9 Controlling Connections with the GPIO Pins Embedded WiFly Microprocessor Module Event The WiFly module is associated with an access point and has a valid IP address This signal instructs the microprocessor that it is OK to open a TCP connection GPIO4 High by WiFly Module Event the microprocessor wants to open a TCP connection to the stored remote host The WiFl
33. 10 command WPS on GPIOO is disabled by default to avoid accidentally invoking the WPS function DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support 2datasphere eu l AN DATASPHERE DWRN171 XX User Manual more than distribution 2 The WPS application is invoked when GPIO9 goes from low to high You can enable this mode on the RN 134 and RN 174 boards by installing and removing the ad hoc factory reset jumper When the WPS application exists it reboots the module to associate with the WPS enabled access point If GPIO9 is high the module boots in ad hoc mode Care must be taken to drive GPIO9 low before the module reboots A good indicator is the red LED on the RN 134 and RN 174 boards When this LED flashes indicating the module is scanning for a WPS enabled access point you should drive GPIO9 low By default the WPS code prints messages on the UART as it scans channels detects access points and tries to complete WPS You can disable these messages using the set sys print 0 command Example Launching a WPS Application lt add an example Status LEDs during WPS Process In WPS mode the LEDs indicate activity e The red LED flashes while the module is scanning for WPS enabled access points e The yellow LED goes on solid while negotiation is in progress with a WPS enabled access point If the process is successf
34. 123 set ftp user my password Sets the user name to my password DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 14 AN DATASPHERE DWRN171 XX User Manual more than distribution set ip address lt address gt This command sets the DWRN171 XX module s IP address where lt address gt is an IP address in the form lt value gt lt value gt lt value gt lt value gt with lt value gt being a number between 0 and 255 If DHCP is turned on the IP address is assigned and overwritten when the module associates with an access point IP addresses are delimited Default 0 0 0 0 Example set ip a 10 20 20 1 Sets the DWRN171 XX module s IP address to 10 20 20 1 set ip backup lt address gt This command sets a secondary host IP address where lt address gt is an IP address in the form lt value gt lt value gt lt value gt lt value gt with lt value gt being a number between 0 and 255 If the primary host IP is unreachable the module attempts to reach the secondary IP address if set Default 0 0 0 0 Example set ip a 10 20 20 2 Sets the DWRN171 XX module s secondary IP address to 10 20 20 2 set ip dhcp value This command enable disable DHCP mode where value is a decimal number shown in Table 3 If you set this parameter the module requests and sets th
35. 171 XX User Manual more than distribution Entering Command Mode By default the module is in data mode Sending the escape sequence causes the module to enter command mode You must type together quickly with no additional characters before or after You do not need to type a carriage return lt cr gt after the to enter command mode The module replies with CMD to indicate it is in command mode Once in command mode you can configure the DWRN171 XX device using simple ASCII commands each command ends with a carriage return cr Most valid commands return AOK invalid ones return an ERR description To exit command mode type exit lt cr gt The module responds with EXIT indicating that it has exited command mode and entered data mode NOTE There is a 250 ms buffer before and after the escape sequence If characters are sent before or after the escape sequence within this 250 ms interval the DWRN171 XX module treats them as data and passes them over the TCP or UDP socket and the module will not enter command mode You can view various parameters such as the SSID channel IP address serial port and other settings and configure them in command mode You send commands to the module through a terminal emulator connected to the UART or via Telnet When using the UART interface the communications settings should match the DWRN171 XX module s stored settings The default is 9600 baud 8 bits no parity 1 stop bit and har
36. ENET ATRE E EEE 63 Enable Ad Hoc Mode in Hardware cecsssssssssssssssessessesssssssssssssesscsessecncsussucsussusaesnesacsnesussussusssseeaeenecacsussucsesseeaeeneeaeeneeneseees 63 Emable Ad HOGIMOGE Ih SOTEWBEE oorr tre i HE e EE EU S ee EVER EAE e ves eR E Ea 63 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu s AN DATASPHERE DWRN171 XX User Manual e Scanning for Access Points in Ad Hoc Mode ccssssesssssssessssessssesssesussessssesscsesussesussesussesussesusseesssesussesuesesusseenssesussecasaeensseeneaeees 64 Analog Sensor Capability cccsessssesssessssssessessssesessessssesessesussesussesussesussessssesussesnssesussesussesussessssesesseeussesesseenssesesseeusaesesseensseeesseeseaeees 65 Sampling Sensor Pins Automatically essent tette intet ate t tenta teinte tate tate tate tate tates ntes saei 65 Using the Built In Sensor POWEP c ccessessssesessessssesscsessssesecsecnssesussesnssessssessssesscsessssesussessesesusseanssesussesussesessesussesusseaueaessseaseaeeeeaes 65 Default Configuration Firmware Version 2 28 sivcsccstorecesetvecdstevececeiveedvenreterscsceverccetersteercececsterstesveneess OF ADHOC usps c 00 0 0S n 9 GARE 67 BROADCAST PARAMETERS 5 iere IRE REH PERENNE RI eR HERREN PERENNE SETA EUR ENTE RS I erta rie eie inteso pe mre
37. HCP server Configuring Ad Hoc Mode You can configure the module to setup an ad hoc network This mode is useful for point to point communications When in ad hoc mode the device appears like an access point with which other Wi Fi devices can associate NOTE Currently the module only supports the OPEN mode for creating ad hoc networks You can enable ad hoc mode via hardware or software commands Enable Ad Hoc Mode in Hardware To enable ad hoc mode using hardware set GPIO9 high 3 3 V at power up For the RN 134 board GPIO9 is on pin 1 on the jumper block J2 For the RN 174 board GPIOO is on the J6 connector Upon power up with GPIO9 high the DWRN171 XX module creates an ad hoc network with the following settings SSID DWRN171 XX GSX XX where XX is the final two bytes of the device s MAC address Channel 1 DHCP OFF IP address 169 254 1 1 Netmask 255 255 0 0 With the ad hoc jumper in place these settings override any current saved configuration settings Enable Ad Hoc Mode in Software To enable ad hoc mode in software you use the set wlan command with the join ssid and chan parameters For example type the following commands in command mode DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 63 AN DATASPHERE DWRN171 XX User Manual more than distribution set wlan join 4 se
38. I hex format set option format 11 Append all key value pairs to the sensor data Connect to a Web Server Automatically You can configure the module to post data to a webserver automatically using the set sys auto value command where value is a decimal number representing seconds For example you can configure the module to connect to the web server every 10 seconds with the set sys auto 10 command When HTTP mode is set the module automatically appends two linefeeds n n to the end of the packet NOTE If the html header contains spaces you must use the character to indicate spaces in the string A space is the command delimiter When the module s command parser sees the S it converts it to a space character Example Connect to Web Server Every 30 Seconds Use the following commands to configure the module to connect to a web server every 30 seconds set com remote GETS ob php obvar WEATHER Setup the HTML string set sys auto 30 Auto connect every 30 seconds set option format 1 Send header automatically when connection is open set ip proto 18 Turn on HTTP mode 0x10 TCP mode 0x2 Connect to a Web Server Automatically when UART Data Is Received The module supports a mode in which it can connect to the web server when it receives UART data NOTE If you attempt to send data by typing characters on the keyboard or if your microcontroller is not sending data fast enough the module sends out small
39. Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 60 AN DATASPHERE more than distribution DWRN171 XX User Manual The most common mode of WPS is the Push Button Mode PBC in which the user simply pushes a button on both the access point and the wireless client e g the datasphere DWRN171 XX module See Figure 15 Figure 15 Push Button WPS The module supports the WPS feature in firmware version 2 28 and higher To upgrade to the current firmware version and download the WPS application refer to the WPS application note on the Support page of the datasphere web site at http www datasphere eu NOTE Modules that ship with firmware version 2 28 or higher already have the WPS application You can confirm whether your module has the application using the Is command See Figure 16 Figure 16 Confirming WPS Application is Installed Tl COM3 Tera Term VT ZEE D File Edit Setup Control Window Help SIZ FLAGS 1 19 3 MiFly EZ8 2 23 1 18 confi g 19 3 MiFly EZX 2 27 12 3 wps app i ae Boot 31 Backup 11 Launching a WPS Application There are two ways to invoke a WPS function e Using the wps command in the console e Using the ad hoc factory reset pin GPIO9 To invoke a WPS function using the ad hoc factory reset mode 1 Enable the WPS function on GPIO9 using the set system trigger 0x
40. Reboot the module NOTE This example assumes that the FTP server is already set up and configured correctly and that the module is already configured to associate with a wireless network Creating Files on the FTP Server Once the module is configured to connect to the FTP server it can create files on the FTP server To create a file you use the ftp put lt filename gt command where lt filename gt is up to 64 bytes This command creates a file on the FTP server with the name DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 59 AN DATASPHERE DWRN171 XX User Manual more than distribution lt filename gt and prints the open string on the UART By default the open string is OPEN After you see OPEN on the UART you can begin writing data in to the file There are two options to close the file e Send the close string which is CLOS by default e Use the FTP close timer with the command set ftp timer value Once you finish writing to the file this timer begins counting down and closes the file when the timer gets to zero The timer is one eighth of value For example to set a 5 second timer the command is set ftp timer 40 The open and close stings are configurable using the following commands set comm open string Set the open string set comm close string Set th
41. SK If you enter exactly 64 characters the module assumes that the passphrase is an ASCII hex representation of the 32 byte PSK and the value is simply stored For passphrases that contain spaces use the replacement character instead of spaces For example my pass word becomes myS passSword You can change the replacement character using the set opt replace command Default rubygirl Example set wlan phrase my password Sets the phrase to my password set wlan rate value This command sets the wireless data rate where value is a value shown in Table 12 Lowering the data rate increases the effective range of the module Table 12 set wlan rate Command Options Value Wireless Data Rate Mbits second 0 1 1 2 2 5 5 3 11 4 7 Invalid 8 6 9 9 10 12 11 18 12 24 default 13 36 14 48 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 29 AN DATASPH ERE DWRN171 XX User Manual diia i 15 54 Default 12 Example set wlan rate 13 Set the data rate to 36 Mbits second set wlan ssid string This command sets the SSID with which the module associates where string is 1 to 32 characters NOTE lt string gt cannot contain spaces If the SSID has spaces use the character to indicate the space For ex
42. Yam ASPHERE more than distribution DWRN171 XX Command Reference Advanced Features amp Applications incl WEB SERVER OEM v2 0 Manual DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu AN DATASPHERE DWRN171 XX User Manual more than distribution Contents a Heo LUNG iTo g AEP AEN A e n E E AE E EN 2 Feature Se E E E EIE 6 COMPUTATION nnn n RENER RN R RRN R R E ENER RN ENES 6 Entering Command MOe i u ssssssssesssssssessssessssesessssssscssssssssscsesscsesscsessssssscsessssessesessssssscsesessesscsessesesscsessesesscsessesesecsessssesecseesesseseseeses 7 Remote Configuration Using Ad Hoc Mode u ccccesesesesesesssesssssssssssssssssssssscscscsesesesesesesesesesesesesesssssesssssssssssacscseseseseseseseseseaeseaeaes 7 Command Reference AEE EEEE EEEE CERCLE R DEED RES DEEER CERE LEE E EOR BERE ER E LEER ESSE EORR ERE EUER SEE R BEER C ERE E RRSEERa ERE E EE Ft Command SV Ta 553555 etie aaa are eao E e Iris ertet DEP ee Ee Ee Ebo EH CREER EE Rea ue Eee ERR RUN 9 Command Organization rettet tei epe RETE ARE RSNUR RES PIE T NHIEU E WEE SE ES ENEE EAE RENE dS 9 Set COMMANA S d cte eminem nM M 10 casedurp5eee P 30 Status COMMANA M 32 Action Commands ntt ae reri TU PUER HIN HRIRIEHISH EAE EE SENDER HERI RSEN R ADU
43. abling LEDs seen nnne 42 Setting the Alternate GPIO Functions tenente tenete tete tete te tette tete te tete te eb ed 44 Controlling Connections with GPIO Pins tette tnter te tente ttti thiet attt aset tette eats ts aad 45 Setting Debug Print Level RRRRRRRRRRRRRRRRRRRRMMMMEEEEEMEEMMMMM 46 Scan Output FOMA E ooi meri etiem eee ee 46 UART Heartbeat Messages 3 e EROR AE O UIN EROR Re Ud 46 Using the Real Time Clock Function esent tente tete tente tete tete tete tete te tette tete tente te toten te tea ed 47 Witte Stamping Pa Ck ts occi eve itii en oth a tid mI nitet EPI RHET 48 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 1 AN DATASPHERE DWRN171 XX User Manual more than distribution Advanced Applications sssssesossssnsesonsoonsononsoonsononooonsenonsnonsononnnonsononsnonsosonsnonsononsnonsosonsnsnsosonsnsesonoosnsesosossnses T D Sending Data using UDP 3 eei ERU RETE aR EE REAR A ESRR 49 LIP XU tO PAIN RES 49 UDP REUN es UE MEME EUM MU 50 UDP Broadcast economie EHR DIM reme 50 Joining Networks amp Making Connections ccccesssssssssesssssssssessssssssssssssessssesscssssesessssessesesscssssesessssesaesessesessesesssseesesesseseeaeseeseeenes 51 Associate with an Access POint ccsessssssssessessecsesessssessessessessesnesuc
44. ake 5 The module wakes after 5 seconds set time address address This command sets the time server address where address is an IP address in the form lt value gt lt value gt lt value gt lt value gt with value being a number between 0 and 255 This command applies to sNTP servers Default 129 6 15 28 Example set time address 208 109 78 52 Sets the time server address as 208 109 78 52 set time port value This command sets the time server port number where value is a decimal number 123 the default is typically the sNTP server port DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 23 AN DATASPH ERE DWRN171 XX User Manual dpa Default 123 Example set time port 1052 Sets the time server port to 1052 set time enable value This parameter tells the module how often to fetch the time from the specified sNTP time server where value is a decimal number representing minutes from 0 to y get max The default 0 disables time fetching If value is 1 the module fetches the time only once on power up If value is greater than 1 the modules fetches the time every value minutes Default 0 Example set time enable 5 The module fetches the time every 5 minutes set time raw value This parameter setting allows you to set the RTC raw
45. akes the module AWAKE pin When the module wakes up from sleep it takes time in milliseconds to initialize the internal hardware During this time any data that is sent to the DWRN171 XX module over the UART is not processed You can monitor signals that indicate the module is ready to accept data as described in Table 16 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 38 DWRN171 XX User Manual AN DATASPHERE more than distribution Table 16 Signals Indicating the Module Can Accept Data GPIO functions Method Interface Description RTS transition RTS pin When the DWRN171 XX module wakes up the RTS pin goes high Once the module is ready the RTS pin is driven low You can monitor this pin with a microcontroller Monitor GPIO4 Alternative Set the alternative functions for GPIO4 GPIOS and GPIO6 see Setting the Alternate GPIO Functions on page 44 When the module wakes up and connects to an access point GPIO4 goes high indicating the module is ready to receive data over the UART A microcontroller can monitor GPIO4 Sensor power Sensor power You can configure the module to output Vbat or 3 3 V or 1 2 V on the sensor power pin when it pin wakes from sleep indicating it is ready to accept data After the module wakes you can open a TCP
46. allows the module to echo to any client that sends a UDP packet Example Turn on Auto Pairing set ip host 0 0 0 0 Set the host to 0 0 0 0 set ip flags 0x40 Set the flag to need desc here gt DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 49 AN DATASPHERE DWRN171 XX User Manual more than distribution UDP Retry This feature adds a level of reliability to the UDP protocol without adding the complete overhead of TCP protocol When enabled the module waits for a response on every UDP packet that is sent any UDP packet coming back in If the module does not receive the response packet by approximately 250 ms the same UDP packet is sent out This process continues until either e A UDP response is seen e A new UDP packet is sent from the module and is acknowledged Example Enable UDP Retry set ip flags lt value gt Enable UDP retry include what value should be to enable this feature UDP Broadcast You can set up the module to generate UDP broadcast packets automatically which is useful for the following reasons e Some access points disconnect devices that are idle UDP broadcast informs the access point that the module is alive and wants to stay associated e Applications can use this feature to automatically discover and configure the module If an application is l
47. ample yellow brick road becomes yellowSbrickS road When you use the get wlan command to view the SSID the module properly displays is as SSIDzyellow brick road Default roving1 Example set wlan ssid my_network Set the SSID to my_network set wlan tx lt value gt This command sets the Wi Fi transmit power where lt value gt is a decimal number from 1 to 12 that corresponds to 1 to 12 dBm The default 0 corresponds to 12 dB which is the maximum TX power Setting the value to O or 12 sets the TX power to 12dBm NOTE This command applies only to the RN 171 module it is not applicable to the RN 131 The transmit power on the RN 131 is fixed to 18 dBm If you send this parameter to the RN 131 it issues an error message ERR Bad Args Default 0 Example set wlan tx 11 Set the TX power to 11 dBm set wlan window value This command sets the maximum IP buffer window size where value is a decimal number representing the number of bytes Default 1460 Example set wlan 1460 Sets the buffer to 1 460 bytes GET COMMANDS These commands begin with the keyword get and they display the module s current values Except where noted the get commands do not have any parameters get adhoc This command displays the ad hoc settings Example get adhoc Show ad hoc settings get broadcast This command displays the broadcast UPD address port and interval DW RN171 XX User Manual Revision 1 1 Printed in Ge
48. and output is shown below SCAN Found 5 01 01 53 00 0200 1a fc 90 e5 a5 37 QTDFW 02 01 59 04 3104 00 15 f9 38 bd b0 SensorNet 03 11 72 04 3104 00 16 b6 45 63 98 CoolBox 04 11 50 02 3100 00 18 02 70 7e e8 airlink 11 05 11 69 04 3100 00 14 6c 1f f7 5e ap ssid change me The security mode field for the this scan format is described below Security Mode Open WEP WPA PSK WPA2 PSK WPA Enterprise WPA2 Enterprise Code 0 1 2 4 6 8 UART Heartbeat Messages In firmware version 2 22 and higher the module can output UART heartbeat messages The bit mapped message is output periodically while the module is in data mode and not connected to a remote host Messages are not output while in command mode The heartbeat message encodes the module s state for the embedded microprocessor Based on the heartbeat message the microprocessor can choose to change the configuration by going into command mode To enable the UART heartbeat messages use the set sys printlvl 0x10 command The output of this mode is 8b30 8b30 8b30 Table 21 shows the output bit format Table 21 Output Bit Format Bt aa 1312 BENIGNE OS ee ee ERES MED RESERVED RESERVED Authentication TCP status Value 2 Access point mode Unused 0 13 Unused 1 OK 1 OK 0 Idle 3 Ad hoc mode 1 Connected 3 No IP 4 Connecting 5 Challenge for password DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wir
49. ate to 7 200 baud set uart flow lt value gt This command sets the flow control mode where value is O or 1 The default is 0 which disables flow control 1 uses hardware RTS CTS NOTE Once flow control is enabled it is important to drive the CTS pin properly i e active low enabled If CTS is high the module does NOT send data through the UART and further configuration in command mode is problematic because no response is received Default 0 Example set uart flow 1 Enables RTS CTS flow control DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 25 AN DATASPHERE DWRN171 XX User Manual more than distribution set uart mode lt mask gt This command sets the UART mode register where lt mask gt is a hex number masking a bit mapped value as shown in Figure 5 Figure 5 set uart mode Command Bit Mapped Register 574 3 2 1 0 NOECHO Disables RX data echoing while in command mode DATA TRIGGER Makes a connection on RX data Reserved Enable sleep on RX BREAK signal UART RX data buffer Note 1 The version string lt x xx gt r n is replaced with the replace character in the command prompt by default Notes 1 With firmware version 2 27 and higher bit 4 s functionality has changed When a TCP
50. b server name set ip host 0 Turn on DNS set ip remote 80 Set the web server port 80 is standard set com remote GETS server php value Set up the server application string set sys auto 10 Automatically connect every 10 seconds set option format 1 Send a HTML header set uart mode 2 Connect automatically using data trigger mode save Save the configuration in the configuration file reboot Reboot so that the settings take effect With these settings enabled the module connects to the web server every time it receives data on the RX line Serial data is sent to the host web server according to the flush timer and the flush size NOTE You cannot append the sampled sensor data to the UART data Enabling option format 7 with set uart mode 2 results in erroneous data UPGRADING FIRMWARE VIA FTP The module has a file system for storing firmware and configuration files Use the Is command to view files The file size is displayed in sectors and the active boot image is identified in the final message For example FL SIZ FLAGS 11 18 3 DWRN171 XX_GSX 2 21 29 1 10 config 190 Free Boot 11 Backup 0 You can store multiple firmware images and configuration files NOTE The module s flash file system only is used to store firmware and configuration files Currently the file system cannot be used to store data files The module contains a built in FTP client for downloading files and updating the firmware The clien
51. ch corresponds to a maximum 1 19 million waking hours The sleep timer is set with the set sys sleep value command where value is a decimal number representing seconds e Wake timer Used to wake the module It is a 22 bit number which corresponds to a maximum sleep time of 1 165 hours T e wake timer is set with the set sys wake value command where value is a decimal number representing seconds e Auto connect timer Used to open a TCP connection automatically e idle timer Used to close a TCP connection automatically The sleep and wake timers are responsible for putting the module to sleep and waking it up If the sleep timer is enabled the module automatically goes into deep sleep low power mode once the timer counts down to 0 The sleep timer is disabled if the module has an IP connection or is in command mode DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 39 AN DATASPHERE DWRN171 XX User Manual more than distribution For example if you want the module to wake up join a network and be available to accept TCP connections for 30 seconds every 2 minutes you would set the timers as shown in the following example set wlan ssid my_net Set the host name set wlan passphrase my_pass Set the passphrase set sys sleep 30 The module sleeps after being awake for 30 s set s
52. cmd on4 output 4 pin with label OW4 goes High 3 3Volt cmd off4 output 4 pin with label OW4 goes Down OV example 192 168 2 66 2000 out3 0n3 OW3 goes High scale1 lt cmd gt cmd is a scale coefficient of proportionality for sensor 1 range 0 0001 9 The sensor 1 input is an analog input with 10 bit ADC converter range 0 3 3V By default scale1 1 so we have for a voltage on sensor1 of 3 3V the value 1023 000 shown in the web page section SENS1 If we want to show 3 3 V in the section web page SENS1 we have to change the scale value with 0 00322 example 192 168 2 66 2000 scale1 0 00322 scale2 lt cmd gt cmd is a scale coefficient of proportionality for sensor 2 range 0 0001 9 The sensor 2 input is an analog input with 10 bit ADC converter range 0 3 3V DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 78 AN DATASPHERE more than distribution DWRN171 XX User Manual By default scale2 1 then we have for a voltage on sensor2 of 3 3V the value 1023 000 shown in the web page section SENS2 If we want to show 3 3 V in the section web page SENS2 we have to change the scale value with 0 00322 example 192 168 2 66 2000 scale2 0 00322 scale3 cmd cmd is a scale coefficient of proportionality for sensor 3 range 0 0001 9 The sensor 3 input is an analog input with 10 bit ADC con
53. connection is closed if there is RX data in the UART receiver it is flushed by default When you enable bit 4 using the set uart mode 0x10 command the module holds the UART data in the buffer until More characters come in after which the buffer is flushed e No characters come in and a new connection is made after which the characters are forwarded Default 0 Example set uart mode 0x10 Enable the UART data buffer set uart tx lt value gt This command disables or enables the UART s TX pin GPIO10 where value is 1 or O Disabling the pin lt va ue gt 0 sets GPIO10 as an input with a weak pull down NOTE The UART does not support even or odd parity it only supports no parity Default need default Example set uart tx 1 Enable the UART s TX pin set wlan auth value This command sets the authentication mode where value is shown in Fehler Verweisquelle konnte nicht gefunden werden You only need to set this parameter if you are using automatic join mode 2 i e the set wlan join 2 command NOTE During association the module interrogates the access point and automatically selects the authentication mode The firmware supports he following security modes WEP 64 and WEP 128 open mode only NOT shared mode WPA2 PSK AES only e WPA1 PSK TKIP only WPA PSK mixed mode some access points not all are supported DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wire
54. connection to a remote host in a number of ways as described in Table 17 You set the remote host using the following commands set ip host lt address gt OR set dns name lt string gt Sets the host s IP address OR URL set ip remote lt value gt Sets the port number on which the host is listening save Save the settings in the configuration file reboot Reboot the module so that the settings take effect Table 17 Methods of Connecting to a Remote Host Method Type Description Auto connect Internal RTC Connect to the host at specific time intervals based upon the set sys autoconn lt value gt timer command setting Open UART In command mode issue the open command Connect on UART data UART mode 2 This mode is designed for the HTML client feature Use the set uart mode 2 command to connect the to host automatically when UART data is received GPIO5 Alternative Set the alternative functions for GPIO4 GPIO5 and GPIO6 see Setting the Alternate GPIO GPIO functions Functions on page 44 Set GPIO5 high to trigger a TCP connection and low to disconnect SYSTEM amp AUTO CONNECT TIMERS The DWRN171 XX module uses a real time clock RTC to generate timers The RTC is active even when the module is asleep allowing you to put the module to sleep and wake it based on timer intervals The module has the following timers e Sleep timer Used to put the module to sleep It is a 32 bit number whi
55. csessesesussesussesussesnssesussesucsesussesuesessseeeaeeesees 56 HTML Client Example Posting Sensor Data Automatically sese tett tette nte teen 57 HTML Client Example Posting UART Data to a Web server tette tette te teste ttn 58 Upgrading ESI ETCRCR SRM 58 Eel am 59 ero reri io DETTA IRL 59 Creating Files on the FTP Server u ccssssssssssesssssssssesssssssssesssssssssessssessesessesessesssssssesssesuesesussesusaesussessssesesscsuesesusseasaesesseeseaeeeeaees 59 Retrieving Files from the FTP Server c csesesssssssessssessssessssesssesscsessssessssessesessssesussessesessesesussesussesussesussesusseeussesuesesuesesesseeeaeeeesees 60 Wi Fi Protected Setup WPS u ceccssesessessssesessessssesessesssesessessssesussessssesusseenssesussesussesussesussesussessssesusseencsesussessssesesseensaesesseensaeseeseeneasees 60 Launching a WPS Application e 61 Status LEDs during WPS Process c ccssssessessssesessesessesssessssesussessssesessessssesussesussesussesussesussessssesessecsssesussessssesesseesesesesseensaeeesseensaeees 62 Scan Output Format Showing WPS Enabled Access Point essent nte tite tn setate tinens 62 Adhoc Networking MOde c ccccssessssssessessssesessessssesessessssesucsessssesussesussesussesussesussesussesussesussesussessssesusseeussesussesnssesessesnsaeeesseeneseeesseeneaees 63 COMPISUFIMNG AG Hoc Mod er siii ern SE e re aa E r Ei TEENE SaS AI SEENE TEASER SEE E
56. cting Association 1 OK Authentication 1 2 OK DNS server 1 server is contacted DNS found 1 DNS is resolved Channel Value 1 13 Fixed Value 8 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 32 AN DATASPHERE DWRN171 XX User Manual more than distribution show io This command displays the GPIO pins level status in the hex format 8 lt ABC gt For example 8103 indicates GPIO O 1 and 8 are high Example show io Show the GPIO level status show net lt char gt The command displays the current network status association authentication etc where lt char gt is the optional parameter n Using the n parameter displays only the MAC address of the access point with which the module is currently associated Example show net n Show the access point s MAC address show q lt value gt This command display the value of the analog interface pin where lt value gt is 0 to 7 The module returns a value in the format 8xxxxx where xxxxx is the voltage in microvolts sampled on the channel you requested NOTE Ifa web post or UDP broadcast samples the data the data is shifted as described in UDP Broadcast on page 50 Example show q 0 Show the voltage on channel 0 show q 0x1 lt mas
57. d Interface Description sleep command UART Go into command mode using and issue the sleep command Sleep Timer Internal RTC The module sleeps based on the set sys sleep value command setting The module sleeps as soon as GPIO8 is held high 4 usec latency To enable this feature use the Drive GPIO8 high GPIO8 iic 8 set sys trigger 0x20 command setting Table 15 describes the methods for waking the module Table 15 Methods for Waking the Module Method Interface Description Sensor input Sensor pins You can wake the module using sensor pins 0 3 1 2 V DC ONLY Use the set sys trigger value 1 2 V DC only command to enable the sensors Rx pin RX pin via The RX pin on the RN 134 and the RN 174 evaluation boards is tied to sensor pin O via a resistor 3 3 V DC only sensor 0 divider network Use the set sys trigger 1 command to wake the module when it receives RX data NOTE With this method the module may drop the first UART data byte A better method is to wake the module using the CTS pin CTS pin CTS pin via The CTS pin on the RN 134 and the RN 174 evaluation boards is tied to sensor pin 1 via a resistor 3 3 V DC only sensor 1 divider network Use the set sys trigger 2 command to wake the module using the CTS pin Wake Ttimer Internal RTC The wake timer wakes the module based on the set sys wake lt va ue gt command setting FORCE AWAKE FORCE An input pulse of at least 31 psecs 3 3 V w
58. ddress and port when GPIOS goes high and disconnects when GPIOS goes low Similarly you can monitor the connection status by reading GPIO6 When it goes high the connection is open when it goes low the connection is closed Use the command set sys iofunc command to enable GPIO6 changed the above commands from set sys io to set sys iofunc because that s what is in the command reference Please let me know if that s wrong Example Use GPIO6 amp GPIO6 to Control Connections set sys iofunc 0x20 Enable GPIO5 set sys iofunc 0x40 Enable GPIO6 Using DNS Settings The module contains a built in DNS client If you do not specify the host s IP address i e it is set to 0 0 0 0 the module uses DNS protocol When you set the host name using the set dns name string command the module automatically attempts to resolve the host address When the address is resolved the module connects automatically To manually look up a host s IP address use the lookup string command where string is the hostname Example Use DNS set dns name my server Set the DNS host name to my server DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 53 AN DATASPHERE more than distribution DWRN171 XX User Manual Using the Backup IP Address Connect Function The module contains a feature for auto ret
59. distribution set opt deviceid lt string gt This command sets the configurable device ID where lt string gt is up to 32 bytes long You can use lt string gt for serial numbers a product name or to show other device information The module sends the device ID as part of the UDP broadcast hello packet You can view the device ID s current value with the get option or show deviceid commands Default DWRN171 XX GSX Example set opt deviceid my_wifly Sets the device ID to my_wifly set opt password lt string gt This command sets the TCP connection password where lt string gt is up to 32 bytes long This setting provides minimal authentication by requiring any remote device that connects to the module to send and match the challenge string When a connection is opened the module sends the string PASS to the remote host The remote host must reply with the exact characters that match the stored password in one TCP packet otherwise the module closes the connection To disable the password feature use 0 the default Default no password required Example set opt password my password Sets the TCP connection password to my password set q sensor mask This command specifies which sensor pins to sample when sending data using the UDP broadcast packet or the HTTP auto sample function where mask is a bit mapped register NOTE In versions of firmware prior to 2 23 this command is named set option sensor
60. dule can be put to sleep using GPIO8 VERSION 2 21 07 11 2010 The firmware checksum the image and compare to the stored values in the file now before committing it to flash and updating the boot record after download If the checksum fails firmware prints UPDATE FAILED and deletes the image VERSION 2 20 06 14 2010 Fixes e Passphrase is now accepts up to 64 chars A bug introduced in 2 19 causes the wlan passphrase to be truncated to 32 characters making it impossible to enter a 32 byte HEX literal PSK e Fixed DHCP status when link to Access Point AP is lost It was still reporting DHCP OK It is now cleared and new DHCP session will start once AP link is reestablished e Fixed a bug whereby UDP receive becomes disabled no packets are received if AP LOST and then re established e Improved handling of AP disconnect and AP link lost due to linkmon timeout or other disconnect e If TCP connection was active connection could be in hung incorrect state and once AP is regained in some cases this would not recover This has been fixed in this version Refer section set ip flags value for more information e Added new setting to the UART mode set uart mode 0x10 Features Disabled the auto join feature when in command mode Auto join causes DWRN171 XX to become unresponsive to or commands during The period when auto joining when auto joining is failing do to non existent AP making it hard to process or interpret commands O
61. dware flow control disabled You can enter command mode locally over the UART interface at any time when not connected and also when connected if the appropriate settings are enabled NOTE datasphere suggests using either the TeraTerm Windows OS or CoolTerm Mac OS X terminal emulator program When the DWRN171 XX module powers up it attempts to auto associate with the access point stored in its configuration settings If the module cannot find the access point it enters auto association mode and scans and attempts to join a network This mode may cause the UART to become unresponsive briefly To avoid configuration problems the auto associate feature is disabled when the module is in command mode making it easy to configure the module The auto associate mode turns on when you exit command mode NOTE If your module is running firmware version 2 20 or lower the auto associate feature is NOT disabled when the module is in command mode Therefore you may lose data sent to the module while it is unassociated making it difficult enter command mode and configure the module You can disable the auto associate feature using the set wlan join 0 command This command prevents the DWRN171 XX module from attempting to associate with a network that does not exist Alternatively enable ad hoc mode upon power up using the GPIO9 ad hoc factory reset jumper If this jumper is high on power up the module does not associate with a network While in ad hoc m
62. e minutes For example to configure the module to get time upon power up see the following example 2 23 set time enable 1 AOK 2 23 get time ENA 1 ADDR 129 6 15 28 123 ZONE 7 To view a complete listing of the time variable use the following command lt 2 23 gt show tt Time 09 02 10 UpTime 653 s RTC 1293567548 Restarts 1 Wake 6 RAW 2345ab NOTE The RAW value is the 64 bit hex RAW value of the RTC which ticks at 32 768 Hz DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 47 AN DATASPHERE more than distribution DWRN171 XX User Manual TIME STAMPING PACKETS You can use the time stamping feature to append 8 bytes to a TCP or UDP packet automatically The set ip flags 0x87 command enables the time stamp and keeps other default settings The time stamp bits from MSB to LSB are User s TCP or UDP packet data 63 56 55 48 47 40 39 32 31 24 23 16 15 8 7 0 The 8 bytes represents the 64 bit raw value of the real time clock register The data is appended before calculating the TCP checksum so that the data passes through the TCP stack correctly This register counts at 32 768 Hz If the timeserver function is enabled the RTC should accurately reflect the real time This register also counts when the module is in sleep mode DW
63. e IP address gateway netmask and DNS server upon association with an access point Any previously set IP information is overwritten Table 3 DHCP Modes Mode Protocol 0 Turns DHCP off The module uses its stored static IP address 1 Turns DHCP on The module attempts to obtain an IP address and gateway from the access point 2 Enables automatic IP which is generally used with ad hoc networks 3 Turns on DHCP cache mode The module uses a previously set IP address if the lease is not expired or the lease survives reboot 4 Reserved for future use Using DHCP cache mode can reduce the time the module requires to wake from deep sleep which saves power The module checks the lease time if it is not expired the module uses the previous IP settings If the lease has expired the module attempts to associate and uses DHCP to obtain the IP settings The DHCP cached IP address does not survive a power cycle or reset Default 1 Example set ip dhcp 0 Turns DHCP off DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 15 AN DATASPHERE DWRN171 XX User Manual more than distribution set ip flags lt mask gt This commands sets the TCP IP functions where lt mask gt is a hex number referring to a bit mapped register See Figure 1 Figure 1 set ip flags Command Bit Mapp
64. e close string Example Put File on FTP Server ftp put demo txt Upload the file demo txt set ftp timer 40 Close the connection 5 seconds after file uploads Retrieving Files from the FTP Server The module can retrieve files from the FTP server The retrieved file is not stored in module s flash memory the module acts as a transporter and passes the file over the UART interface as the file is being transferred To retrieve a file from the FTP server issue the ftp get filename command The module prints the open string on the UART and the file begins transferring from the FTP serer to the module When the file transfer complete the module prints the close string indicating the file is transferred and the FTP connection is closed Example Retrieve File from FTP Server ftp get demo txt Download the file demo txt from the FTP server WI FI PROTECTED SETUP WPS Wi Fi Protected Setup WPS is a standard for easy and secure establishment of a wireless home network This standard was created by the Wi Fi Alliance and officially launched on January 8 2007 The goal of the WPS protocol is to simplify the process of configuring security on wireless networks The protocol is meant to allow home users who know little of wireless security and may be intimidated by the available security options to configure Wi Fi Protected Access which is supported by all newer Wi Fi certified devices but not older Wi Fi devices DW RN171 XX User
65. e development Leave at default value TIME SERVER PARAMETERS Enable 0 disabled Server address 129 6 15 28 fixed to port 123 SNTP protocol Zone 7 Pacific time USA UART PARAMETERS Baudrate 9600 Flow 0 disabled Mode 0 WLAN PARAMETERS SSID roving1 Channel 0 Automatic scan External antenna O Off use on board chip antenna for RN 131 ONLY Join mode 1 Automatically scan and join based on SSID DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 69 AN DATASPHERE DWRN171 XX User Manual A Authentication mode OPEN Mask Ox1FFF All channels Rate 12 24 Mbit Linkmon 0 Passphrase rubygirl TX Power 0 which implies 12 dBm Applicable to RN 171 module only RESTORING DEFAULT CONFIGURATION SETTINGS You can restore the default factory configuration settings in software and hardware e Software In command mode use the factory RESET command to restore the defaults This command automatically loads the default settings and executes a save command Next send the reboot command so that the module reboots with the default configuration e Hardware Set GPIO9 high on power up to arm the factory reset function Then toggle GPIOO five 5 times which restores the configuration to the factory reset GPIO9 is sampled at about 1 Hz so if you are using a CPU to generate the sig
66. e eu support datasphere eu b50 AN DATASPHERE DWRN171 XX User Manual more than distribution The packet is 110 bytes of data as shown in Figure 10 Figure 10 UDP Broadcast Packet Byte Format Position 0 5 6 7 8 9 10 13 14 15 16 17 18 31 32 59 60 91 92 93 94 110 Access Point s MAC Address 6 Bytes Channel 1 Byte RSSI 1 Byte Local TCP Port 2 Bytes RTC Value MSB to LSB 4 Bytes Pin 20 s Battery Voltage in mV e g 2755 2 Bytes GPIO Pin Value 2 Bytes ASCII Time 13 Bytes Version String with Date Code 26 Bytes Programmable Device ID Set with set option deviceid string 32 Bytes Boot Time in ms 2 Bytes Sensor 0 7 Voltage Readings Enabled with set opt format mask 16 Bytes NOTE To add sensor data to the UDP broadcast message you must enable the sensors using the sensor mask The set q sensor Oxff command enables all sensors Example need example set broadcast insert example describe JOINING NETWORKS amp MAKING CONNECTIONS Configuring the module to make connections involves associating with an access point and opening a connection Before you can configure the module over the WiFi link you must associate the module with a network and program the network settings Therefore the best method is to configure the module u
67. ection open 10 20 20 62 2000 Open host shown in Figure 13 To make a connection from the module you need your server application s IP address and port number A COM port redirector is a simple program you can use to test this functionality This software opens an IP port and transfers all data it receives to a specified COM port on your machine A free COM port redirector program for Windows is available from Pira at http www pira cz eng piracom htm In your COM port redirector program note your computer s IP address e g by typing the ipconfig command in the Microsoft Command Window Go to your terminal emulator and put the module into command mode Type the open lt address gt lt port gt command The server reports that the connection is open and you can type characters into the UART window and see them on the server window or vice versa DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 52 AN DATASPHERE DWRN171 XX User Manual more than distribution Setting up Automatic Connections Some applications require the module to connect to a remote server send data and then disconnect automatically upon power up or wakeup You can configure the module to perform this functionality automatically Set the network SSID and security and set autojoin to 1 When the module wakes up or is powered on t
68. ed Register 7 6 5 4 3 2 1 0 TCP connection status See Notes 1 2 Bypass Nagle algorithm and use TCP_NODELAY TCP retry enabled for a total of 96 packet retries UDP RETRY attempts retry if no ACK from UDP DNS host address caching enabled ARP table caching enabled UDP auto pairing enabled Add 8 byte timestamp to UDP or TCP packets Notes 1 Ifthe module loses the link to an associated access point while a TCP connection is active the TCP connection may hang or be in an inconsistent state In some cases the TCP connection will not recover In firmware version 2 20 and higher if the module regains the link to the access point within 60 seconds the TCP connection will survive 2 In firmware prior to version 2 20 bit O specified the TCP copy function If bit O is set the default TCP connections are kept open when the connection to the access point is lost If bit O is cleared e g by sending set ip flags Ox6 if the module loses the access point connection while TCP is connected the connection is closed Default 0x7 Example set ip flags 0x6 Clear bit O set ip gateway lt address gt This command sets the gateway IP address where lt address gt is an IP address in the form lt value gt lt value gt lt value gt lt value gt with lt value gt being a number between 0 and 255 If DHCP is turned on the gatewa
69. egister For more details see Setting GPIO Direction Alternate Functions amp Disabling LEDs on page 42 Default 0x0 Example set sys iofunc 0x7 Disables the DWRN171 XX evaluation board LEDs DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 20 AN DATASPHERE DWRN171 XX User Manual more than distribution set sys mask lt mask gt This command sets the I O port direction where lt mask gt is a hex number referring to a bit mapped register For more details see Setting GPIO Direction Alternate Functions amp Disabling LEDs on page 42 NOTE To set the GPIO pins as inputs or outputs instantly use the set sys mask OxABCD 1 command which does not require a reboot Default Example Ox20FO0 for RN 131 and Ox21FO0 for RN 171 set sys mask 0x0 Sets all pins as inputs set sys printlvl value This command controls the debug print messages printed by the DWRN171 XX module on the UART where value is one of the values shown in Table 6 Refer to Setting Debug Print Levels on page 46 Table 6 Debug Print Message Settings Value Description 0 Quiet mode Messages are not printed when the module wakes up or powers up 1 Print all status messages 2 Print only critical network access point connection level status e g Associated or D
70. eless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 46 AN DATASPHERE DWRN171 XX User Manual more than distribution USING THE REAL TIME CLOCK FUNCTION The module s real time clock keeps track of the number of seconds since the module was powered on and the actual time when the module synchronized with the sNTP time server By default the module keeps track of up time but does not synchronize with the time server because this synchronization requires the module to be associated with a network that can access the sNTP server The real time clock reads the time in seconds since 1970 which corresponds to the UNIX time In firmware version 2 23 and higher you can set the RTC value in seconds using the set time rtc lt value gt command The default sNTP server is ADDR 129 6 15 28 123 ZONE 7 GMT 7 Use the show time command to see the current time and uptime as shown below lt 2 23 gt show t Time 08 43 10 UpTime 10 s To set the time use the time command lt 2 23 gt show t Time NOT SET UpTime 8 s 2 23 time 2 23 showt Timez08 51 31 UpTime 15 s NOTE The module must be associated with a network for the module to contact the sNTP server Tthe module can also be configured to get the time whenever it powers up using the set time enable 1 command If you set the time enable to a value greater than 1 the module pulls the time continuously every valu
71. er For custom WEB SERVER application is possible to send commands and retrieve the data from DW RN171 XCW in XML format To retrieve XML data you have to use the parameter format xml like is reported in paragraph 4 For example 192 168 2 66 2000 format xml web server response XML 1 It is possible to add more parameters to 1 as is reported in paragraph 4 The OEM web server receives the parameter format xml and return the following XML data params title WEB SERVER OEM DEMO 0 lt title gt out1 1 out1 lt out2 gt 0 lt out2 gt lt out3 gt 0 lt out3 gt lt out4 gt 0 lt out4 gt lt sens1 gt 75 9600 lt sens1 gt lt sens2 gt 406 0000 lt sens2 gt lt sens3 gt 354 0000 lt sens3 gt lt sens4 gt 358 0000 lt sens4 gt lt scale1 gt 0 09 lt scale1 gt lt scale2 gt 1 lt scale2 gt lt scale3 gt 1 lt scale3 gt lt scale4 gt 1 lt scale4 gt lt params gt Example PHP code File Main php lt php DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 81 AN DATASPHERE DWRN171 XX User Manual more than distribution include xmlpars php Sxml file_get_contents http 192 168 1 168 2000 format xml amp title offt amp out1 on1 Sresult xml2array Sxml Stitle Sresult params title Sout1 Sresult params out1 Sout2 Sresult params o
72. er is set to 0 the pass phrase or passkey is displayed If you set this parameter to 1 the module shows for these fields when displaying the WLAN settings To show the pass phrase or passkey re enter the key or pass phrase using the set wlan key or set wlan passphrase command Default 0 Example set wlan hide 1 Hide the pass phrase or passkey set wlan key lt value gt This command sets the 128 bit WEP key where value is EXACTLY 26 ASCII chars 13 bytes in hex without the preceding Ox Hex digits greater than 9 can be either upper or lower case If you are using WPA or WPA2 enter a pass phrase with the set wlan passphase command Default Not applicable Example set wlan key 112233445566778899AABBCCDD Sets the passkey NOTE The module only supports open mode 128 bit keys for WEP WEP 128 shared mode is not supported because it is easily compromised and has been deprecated from the WiFi standards set wlan linkmon value This command sets the link monitor timeout threshold where value is a decimal number from 0 to x need max representing the number of failed scans before the module declares AP is Lost and de authenticates If you set this parameter to 1 or more the module scans once per second for the access point with which it is associated The module re attempts the association based on the join policy setting datasphere recommends setting the threshold to 5 attempts because some access points do no
73. er telnet the scan result is sent over telnet and ad hoc mode is restored DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 64 AN DATASPHERE DWRN171 XX User Manual more than distribution ANALOG SENSOR CAPABILITY The module has 8 analog sensor inputs that can be driven between 0 to 1 2 V DC You can sample the analog inputs and read digital value using the show q lt value gt command where lt value gt is a decimal number representing the channel See show q lt value gt on page 33 for more details WARNING Driving these inputs above 1 2 V can permanently damage the module The channel is the analog sensor input from 0 to 7 The value for the analog sensor input is measured in microvolts and is returned as 8xxxxx where the beginning 8 is a start marker You can also sample multiple channels by using a bit mask using the show q Ox1 mask command where mask is a bit mask of the channels See show q 0x1 lt mask gt on page 33 for more details Example Read Channels 0 1 amp 7 show q 0x183 Read channels 0 1 and 7 The results are in the format 8 channel 0 8 channel 1 gt 8 lt channel 7 gt r n The analog input hardware specification is Input voltage range 0 1 2 V however the analog to digital converter saturates at 400 mV Resolution 14 bits 12 uV Sampl
74. ers The TCP connection timers control when the module opens or closes a socket Opening a TCP Connection In TCP client mode the auto conn timer controls the establishment of a socket connection When set the device periodically attempts to establish a connection when the timer expires The set sys autoconn value command causes the module to connect to the host periodically The timer value determines how often to connect to the stored remote host If set to 1 the module makes one attempt to auto connect upon power up If set to 2 or higher auto connect re opens the connection after the connection is closed The default 0 disables the timer NOTE You must specify the remote host s IP address and port number in the module s configuration file for the auto connect timer to work DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 40 AN DATASPHERE DWRN171 XX User Manual more than distribution Closing the TCP Connection The module supports a disconnect timer in both TCP client and server mode default mode You can use this timer to close a TCP connection automatically after a specified number of seconds of no transmit or receive data To set the disconnect timer use the set comm idle lt value gt command where lt value gt is the number of seconds The default comm idle timer value is 0 w
75. eset high or power good to boot code loaded 70 Initialization Initialize ECOS 50 Ready Load configuration and Initialize application 30 Join Associate using channel 0 full channel scan mask Ox1FFF 80 Associate using channel 0 primary channel scan mask 0x421 15 Associate using channel X fixed channel 5 20 Authentication Authenticate using WPA1 or WPA2 highly dependent on access point response 50 250 Aquire IP DHCP obtain IP address highly dependent on DHCP server response time 30 s DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 71 AN DATASPHERE DWRN171 XX User Manual more than distribution SUPPORTED ACCESS POINTS The module should work with any standard access point datasphere has tested the module with the following access points Cisco Aeronet series Linksys both standard and open WRT Linux Netgear WGR614 v8 Netgear WGN54 DLINK dir 615 Airlink 101 Apple Airport express Buffalo networks Ad hoc mode Apple iPhone Microsoft Windows PC with XP Vista Ubuntu Linux Access points that are set to MIXED mode WPA1 and WPA2 may cause problems during association because some of them incorrectly report their security mode datasphere currently does not support WPA2 Enterprise radius server authentication EAP TLS DW RN171 XX User Manual Revi
76. essssesscsessssessssessesesscssecsssscsuesssucscsessssscsssessssecscsessssesscseeseseescseesesesess 77 Multiple GET paramet r scite eet NEHS OE CREER HIVE EE S EET WERDE E ENE EENG 79 WEB PAGE to control outputs and read SENSOMS secessesessessssesessessssesscsecsssesessesscsessssessesessssessesecssseesssesssseesssesssseensseensseensseees 80 XML response webserver essecessesessessssesessessssesscsesussesuesessssesussessssesussessssesussessssesussessssesusseesssesesseesssesussesuesessesessssesesseensaeeesseensasees 81 Current Firmware Features amp FIXES cesscssssccsccccesssssssssc00ccessssossss000000seese00vDss0000cceeseou00s000ccsesseossnssc000b 4 Version 2 30 10 26 201 RARER E E EEE ID IL DUELDUHLIU LIS MERE LUE 84 Version 2 27 09 08 11 eee eee eee a p e Ee ume eiie esteso eines 84 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 4 AN DATASPHERE more than distribution DWRN171 XX User Manual V6r5i0Rn 2 23 04 037201 1 roine E R ID M MU E M RUE E cece 84 Version 2 21 07 11 20TQ itane ntes testing DN REL oees 85 Versi n 2 20 06 14 2010 erii tt tt nee ttt t eene ete remet nee tit eene teca ee eei bue nne stt ERA 85 dra 85 dre TE 85 DW RN171 XX User Manual Rev
77. etmask 255 255 0 0 Sets the netmask to 255 255 0 0 set ip protocol flag This command sets the IP protocol where flag is a bit mapped register as shown in Figure 2 To be able to connect to the DWRN171 XX module over TCP IP for example using Telnet you must set bit 2 of the IP protocol register For the module to accept both TCP and UDP set bits 1 and 2 value 3 Figure 2 set ip protocol Command Bit Mapped Register 4 3 2 1 0 UDP TCP server and client default Secure mode only receive packets form an IP address that matches the stored host IP TCP client only HTTP client mode Default 2 changed this to 2 which is what it says in section 19 default config settings Example set ip protocol need to get example Sets the IP protocol register to xxx set ip remote value This command sets the remote host port number where value is a decimal number representing the port Default 2000 Example set IP remote 1025 Sets the remote host port to 1025 set ip tcp mode mask This command controls the TCP connect timers DNS preferences and remote configuration options mask is a hex number referring to a bit mapped register as shown in Figure 3 NOTE The TCPMODE register is available in firmware version 2 27 and higher DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp
78. fig default Default config Example save Saves the configuration settings to the config file save my_config Saves the settings to the my_config file boot image lt value gt This command makes a file represented by lt va ue gt the new boot image Example boot image 123 Set the new boot image to a file represented by 123 ftp update lt string gt This command deletes the backup image file retrieves a new image file and updates the boot pointer to the new image where lt string gt is the new image file to retrieve Refer to Upgrading Firmware Via FTP on page 58 for more information Default lt is there a default Example ftp update wifly GSX img Retrieve the file wifly GSX img DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 37 tm DATASPHERE DWRN171 XX User Manual more than distribution ADVANCED FEATURES amp SETTINGS This chapter describes the DWRN171 XX module s advanced features including techniques to put the module to sleep wake up and methods to open a TCP connection when awake It also describes the UART flow control alternative GPIO functions and the real time clock PUTTING THE MODULE TO SLEEP amp WAKING IT Table 14 describes the methods for putting the module to sleep Table 14 Methods for Putting the Module to Sleep Metho
79. ful to demonstrate that DNS is working and that the device has Internet connectivity 0 This option terminates a previously issued ping command DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 35 AN rn m EE DWRN171 XX User Manual i is address Ping a remote host where address is an IP address in the form value value value value with value being a number between 0 and 255 Default 1 packet Example ping 10 20 20 12 10 Ping 10 20 20 12 10 times reboot This command forces the module to reboot similar to a power cycle Example reboot Reboot the module scan value char This command performs an active probe scan of access points on all 13 channels where value is an optional parameter representing the time in ms per channel char represents the optional parameter P which causes the module to perform a passive scan and list all access points it can see in passive mode When you use this command the module returns the MAC address signal strength SSID name and security mode of the access points it finds The default scan time is 200 ms channel or about 3 seconds You can also use this command in ad hoc mode Default 200 ms channel Example scan 30 Scan for 30 ms channel sleep This command puts the module to
80. ge the DWRN171 XX module downloads the file and issues the UPDATE FAIL 3 error Default Example wifly GSX img used for the RN 131 To update the RN 171 use wifly EZX img set ftp filename my_data Sets the firmware image to be retrieved via FTP as my_data set ftp mode lt mask gt This command sets the ftp mode where lt mask gt indicates active or passive mode Default Example 0x0 set ftp mode 0x1 Enables active FTP mode set ftp remote lt value gt This command sets the FTP server s remote port number where value is the port number Default Example 21 set ftp remote 25 Sets the FTP server s remote port to 25 set ftp time value The command sets the FTP timeout value where value is a decimal number that is five times the number of seconds required The module uses this timer to close the FTP connection automatically after the specified time Default Example 40 set ftp timer 40 Sets a 5 second timer set ftp timer 80 Sets a 10 second timer set ftp user lt string gt This command sets the user name for accessing the FTP server where string is up to XX insert max characters Default Example roving set ftp user my username Sets the user name to my username set ftp pass string This command sets the password for accessing the FTP server where string is up to XX insert max characters Default Example Pass
81. he auto connect timer causes the module to attempt a connection to the stored remote IP address and port The sleep timer does not decrement while this connection is open and the idle timer does not decrement while data is flowing When data stops for 5 seconds the connection is closed the sleep timer puts the module in deep sleep The wake timer begins the cycle again one minute later NOTE You can also use ad hoc mode autojoin 4 however there will be a delay connecting to the ad hoc network from the remote computer Therefore make the sleep timer large enough to allow the network to get set up and the auto connect to establish a TCP connection Example Automatic Connection set ip host lt address gt Set up the remote machine s IP address set ip remote_port lt value gt Set up the remote machine s IP port set sys autoconn 1 Automatically connect when ready set com idle 5 Disconnect after 5 seconds with no data activity set sys sleep 2 Sleep 2 seconds after connection is closed set sys wake 60 Wake up after 1 minute of sleep set uart mode 2 Use UART data trigger mode which causes the module to make a TCP HTTP connection upon incoming UART data supported in firmware version 2 19 and higher Controlling Connections using GPIO5 amp GPIO6 You can use GPIOS to control the TCP connection After you configure the pin with the set sys iofunc command the module attempts to connect to the stored IP a
82. hich means the module never disconnects when idle For example to close the TCP connection after 5 seconds of inactivity use the set comm idle 5 command WAKE ON SENSOR INPUT Four sensor inputs 0 to 3 wake the module from sleep These pins have a small current source that is activated in sleep mode This source is approximately 100 nA and causes the input to float up to about 1 2 V DC If for example SENSE1 is enabled pulling the SENSE1 pin to ground wakes the device To enable the sensors to wake the module use the command set sys trigger lt mask gt where lt mask gt is a bit mapped setting of each sensor For example to wake the module using sensor pin 2 use set sys trig 4 Setting the trigger value to 0 disables all sensor pins Table 18 describes the values to wake the module using individual sensor inputs Table 18 Sensor Input Values Wake on Sensor Input Value Command 0 1 set sys trigger 1 1 2 set sys trigger 2 2 4 set sys trigger 4 3 8 set sys trigger 8 WARNING The voltage on any sensor input CANNOT exceed 1 2 V DC or the module will be permanently damaged The sensor inputs are rated 1 2 V DC maximum You must use a resistor divider when driving a sensor pin from the other 3 V pins such as RX You should use a resistor divider network with a minimum of 24 K in series and 10 K to ground from the UART RX or CTS pin An open drain FET is an appropriate device to tie to the sensor
83. ing frequency 35 us Accuracy 596 un calibrated The accuracy of each analog sensor reading can be offset by up to 596 due to variations from chip to chip To improve accuracy datasphere recommends using a precision reference voltage on one of the analog inputs to calculate the offset The offset is the same for all analog inputs For example e Drive precision 200 mV reference on analog input 4 e Read analog input 4 and compute the offset If you read 210 mv you know that the offset is 10 mv When you read input 5 subtract 10 mv from the result Sampling Sensor Pins Automatically The sensor pins can be sampled automatically and data forwarded in two modes e The UDP broadcast packet can contain the sample values e In HTTP mode the sampled pin data can be forwarded to a remote server To enable these modes use the set q sensor mask command Example Sample All Sensor Inputs set q sensor Oxff Sample all sensor inputs Using the Built In Sensor Power The modules contain an on board sensor power pin which is controlled by the set q sensor mask command mask is a bit mask value that determines which sensor pins to sample when sending data using the UDP broadcast packet or the HTTP auto sample function See set q sensor lt mask gt on page 19 for more details NOTE In versions of firmware prior to 2 23 this command is named set option sensor DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphe
84. isconnect from SSID 4 Print the DHCP and IP address status information After you have verified the module s configuration you can turn off this option so that the messages do not interfere with the data 0x4000 Print the new scan format output 0x10 Enables the UART heartbeat message See UART Heartbeat Messages on page 46 for more details lt update reference gt Default 0x1 Example set sys printlvl 2 Sets the debug print messages to only critical network connection status lt The default in section 19 has 0x1 which is hex Do we need to use mask instead of value And what should the example be in hex gt set sys output lt mask gt lt mask gt This command sets the output GPIO pins high or low where lt mask gt is a hex number referring to a bit mapped register The optional lt mask gt sets a subset of the pins Default Example lt need to add gt To toggle GPIO8 use the following commands set sys mask 0x21f0 Set GPIO8 as output set sys output 0x0100 0x0100 Drives GPIO8 high set sys output 0x0000 0x0100 Drives GPIO8 low DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 2s AN DATASPHERE DWRN171 XX User Manual more than distribution set sys sleep lt value gt This command sets the sleep timer where lt value gt is a decimal number fro
85. ision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu bo AN DATASPHERE DWRN171 XX User Manual more than distribution INTRODUCTION The datasphere DWRN171 XX radio module is a complete standalone embedded wireless LAN access device The device has an on board TCP IP stack and applications and it only requires four pins power TX RX and ground Once you have performed the initial configuration the device automatically accesses a Wi Fi network and sends receives serial data over the UART This user manual is applicable to standalone DWRN171 XC DWRN171 XU and DWRN171 XCW as well as datasphere hardware that includes these modules Refer to the DWRN171 XX data sheets on the datasphere website at http www datasphere eu for detailed hardware specifications FEATURES e Fully qualified and Wi Fi Certified 2 4 GHz IEEE 802 11 b g transceiver FCC CE ICS certified and RoHS compliant e Ultra low power o Intelligent built in power management with programmable wakeup o Accepts 3 3 V regulated or 2 to 3 V battery with on board boost regulators o IEEE 802 11 power save and roaming functions o 4uAsleep 35 mA Rx 185 mA Tx at 12 dBm Tx power configurable e Antenna options o DWRN171 XCW On board ceramic chip antenna o DWRN 171 XUW U FL connector for external antenna e Hardware o 8 Mbit flash memory and 128 Kbyte RAM 2
86. istening for the UDP broadcast a number of useful parameters are present in the package that can be used for auto discovery For example the module s IP address and port number are part of the packet thus an application can connect to the module and remotely configure it e The associated access point s MAC address channel and RSSI value are also available in this packet enabling a simple location and tracking function By default the module sends out a UDP broadcast to 255 255 255 255 on port 55555 at a programmable interval You set the broadcast address port and interval using the set broadcast commands NOTE Youcan send the module s sensor data out via UDP broadcast The analog to digital convertor is 14 bits on a 400 mV signal which translates to about 24 uVolts 0x61A80 in hex When you use the show q command in command mode the module displays the raw readings However for HTTP web posting and UDP broadcast packets the module shifts the reading by 4 bits which is a divide by 16 resulting in a 16 bit number Therefore if you want the actual voltage sampled you must take the 16 bit number and shift it left by 4 bits to get the number of microvolts If you the value in millivolts and do not need high accuracy right shift by another 6 bits which is the same as dividing by about 1K DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www dataspher
87. k gt This command displays multiple analog interface values simultaneously where lt mask gt is a bit mask representing the channels For example to read channels 0 1 and 7 use the command show q 0x183 The module returns 8 lt chanO gt 8 lt chan1 gt 8 lt chan7 gt NOTE If a web post or UDP broadcast samples the data the data is shifted as described in UDP Broadcast on page 50 Example show q 0x183 Show values for channel 0 1 and 7 show rssi This command displays the last received signal strength Example show rssi Show signal strength show stats This command displays the current statistics packet RX TX counters etc Example show stats Show the statistics show time This command displays the number of seconds since the module was last powered up or rebooted Example show time Show seconds since last power up DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 33 AN DATASPHERE DWRN171 XX User Manual more than distribution ACTION COMMANDS The action commands allow you to enter and exit command mode join networks etc Except where noted these commands do not have any parameters You use this command to enter command mode You must type together quickly with no additional characters before or after You do not need to type a carriage return
88. less Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 26 AN DATASPHERE DWRN171 XX User Manual more than distribution Table 10 set wlan auth Command Authentication Modes Value Authentication Mode 0 Open Default 1 WEP 128 2 WPA1 3 Mixed WPA1 and WPA2 PSK 4 WPA2 PSK 5 Not used 6 Ad hoc mode join any ad hoc network 8 WPE 64 Default 0 Example set wlan auth 4 Use WPA2 PSK authentication set wlan channel value This command sets the WLAN channel where value is a decimal number from 1 to 13 representing a fixed channel If you set the channel to 0 the modules performs a scan using the SSID for all the channels set in the channel mask Default 0 Example set wlan channel 2 Set the WLAN channel to 2 set wlan ext antenna value This commands determines which antenna is active where value is O use the chip antenna or 1 use the U FL connector Only one antenna is active at a time and the module must be power cycled after changing the antenna setting NOTE This command applies only to the RN 131 module it is not applicable to the RN 171 If you send this parameter to the RN 171 it issues an error message ERR Bad Args Default 0 Example set wlan ext antenna 1 Use the U FL antenna set wlan join value This command sets the policy for automatically associating with network access points where
89. m 0 to xx seconds lt need max gt The sleep timer is the time in seconds after which the module goes to sleep This timer is disabled during an open TCP connection When the TCP connection is closed the module counts down and puts the module to sleep after lt va ue gt seconds Setting the value to 0 disables the sleep timer and the module will not go to sleep based on this counter NOTE Be sure to set the wake timer before issuing the sleep timer if you are not using an external wake up signal otherwise the module will never wake up See System amp Auto Connect Timers on page 39 for more details on using system timers Default 0 Example set sys sleep 5 The module sleeps after 5 s after the TCP connection closes set sys trigger flag or mask pls confirm that the description is correct for this one From text it looked like you use either a flag or mask but wasn t sure if that was correct With this parameter setting the module wakes from sleep state using the sensor input 0 1 2 and 3 where flag is a decimal number referring to a bit mapped register as shown in Table 7 and mask is a hex number You use either flag or mask with this parameter setting This command sets the sensor input s to wake on 0 to 3 Setting flag to 0 disables wake on sensor inputs Table 7 set sys trigger Command Bit Mapped Register Bit Position Description 0 Trigger sensor
90. mber of bytes received before forwarding The maximum is 1 460 bytes which is the size of a single Ethernet frame e set comm time value sets the flush timer which is used to ensure that any partial data sitting the RX buffer something missing here make sure partial data is sent if no additional data is received for value ms For example the set comm time 1000 command causes the module to wait for 1 second after no data was sent If the module will be sending more than a few hundred thousand bytes in a single transaction you should enable hardware flow control Your hardware must actively monitor the CTS pin Flow control is not enabled by default you set it with the set uart flow 1 command It is possible to operate higher baud rates i e greater than 115 K without flow control if the packets are uniform and you use an application protocol to ensure that the packet data is delivered on the remote side before the next packet is sent However given the uncertainty of packet delays in a TCP IP network and the affects of interference and retries inherent in wireless networks flow control is typically required whenever large contiguous quantities of data are being written to the UART to guarantee no data is lost Setting GPIO Direction Alternate Functions amp Disabling LEDs You can control the GPIO pin direction with the GPIO mask using the set sys mask value command where value is entered as a hex number The hex nu
91. mber represents a bitmask that controls each pin where 1 output and 0 input For example set sys mask 0x0 Sets all pins as inputs set sys mask OxcO Set only GPIO6 and GPIO7 If you only need to set one bit in the mask you need to read mask and set the value Otherwise you will overwrite any previous GPIO settings The default mask for the RN 131 module is Ox20f0 which sets GPIO13 GPIO7 GPIO6 GPIO5 and GPIO4 as outputs The default mask for the RN 171 module is 0x21f0 which corresponds to the following settings e GPIOO 3 are used internally on the module e GPIO4 6 are LEDs DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 42 AN DATASPHERE DWRN171 XX User Manual more than distribution e GPIO 9 is reserved as the ARM factory reset ad hoc mode read at power up and otherwise general purpose input detect pin e GPIO10 11 are the UART RX and TX pins TX does not need to be masked as an output e GPIO12is CTS input if used e GPIO13 is RTS output if used NOTE To set the GPIO pins as inputs or outputs instantly use the set sys mask OxABCD 1 command which does not require a reboot The RN 134 evaluation board s LEDs are connected to GPIO4 6 To disable the LEDs enable the alternative functions of the LEDs use the set sys iofunc 0x7 command NOTE Youcan tur
92. n format 1 Convert binary data to ASCII hex format For example if the incoming UART data is 6 bytes of binary data with hex values 0x01 OxAB 0x03 OxFF 0x05 and 0x06 the module sends this string GET userprog php DATA 01AB03FF0506 n n to the web server Post Sensor Data Automatically The module can send the value of the GPIO and sensor pins to the web server automatically The data arrives as 18 bytes of ASCII hex data in the format 2 bytes GPIO gt lt channel 0 thru 7 sensor data NOTE The analog to digital convertor is 14 bits on a 400 mV signal which translates to about 24 uVolts 0x61A80 in hex When you use the show q command in command mode the module displays the raw readings However for HTTP web posting and UDP broadcast packets the module shifts the reading by 4 bits which is a divide by 16 resulting in a 16 bit number Therefore if you want the actual voltage sampled you must take the 16 bit number and shift it left by 4 bits to get the number of microvolts If you the value in millivolts and do not need high accuracy right shift by another 6 bits which is the same as dividing by about 1K Example Post Sensor Data to Web Server set ip proto 18 Turn on HTTP mode 0x10 and TCP mode 0x2 set dns name www webserver com Set the web server name set ip host 0 Turn on DNS set ip remote 80 Set the web server port 80 is standard set com remote GETS userprog php DATA Sample server application set
93. n off the yellow red or green LEDs The RN 134 board s blue LED is the power indicator and cannot be turned off The RN 174 evaluation board s blue LED is connected to GPIO7 which is output by default The board does not drive this because GPIO7 s default power up state is low The get sys command shows the setting of the GPIO mask as shown in the following example 2 21 get sys SleepTmr loFunc 0x0 loMask 0x21f0 Figure 8 shows the bits corresponding to the GPIO pins ws the GPIO pin usage their default state and functionality Figure 8 GPIO Pin Bitmask 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 GPlO14 GPIOO GPIO13 UART RTS GPIO1 GPIO12 UART CTS GPIO2 GPIO11 UART RX GPIO3 GPIO10 UART TX GPIO4 GPIO9 GPIO5 GPIO8 GPIO6 GPIO7 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 43 AN DATASPHERE DWRN171 XX User Manual more than distribution Table 19 GPIO Pin Usage Default State amp Functionality Bit ad EE Default Function 0 GPIOO N A 1 GPIO1 Input Unused 2 GPIO2 Input Unused 3 GPIO3 Input Unused 4 GPIO4 Output Green LED 5 GPIO5 Output Yellow LED 6 GPIO6 Output Red LED
94. nal make sure that GPIO9 transitions high to low or low to high are at least 1 second long With firmware version 2 10 and higher you can specify a user configuration file as the factory reset settings Prior to this firmware version only the hardcoded factory defaults would be restored If you have stored a configuration file named user the module reads it as the factory default instead of using the factory hardcoded defaults If no user configuration file is present the module uses the hardcoded factory defaults You create the user configuration file using the save user command which saves the current configuration settings into a file named user Even if a user configuration file exists arming and toggling GPIO97 times overrides the user settings and restores the module to the factory hardcoded defaults This bypass mechanism allows you to restore the factory defaults in case a bad configuration is saved into the user file NOTE You must reboot the module or reset it for the new settings to take effect DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 70 AN DATASPHERE more than distribution DWRN171 XX User Manual BOOT UP TIMING VALUES Table 23 shows the boot up timing values Table 23 Boot Up Timing Values Description Time ms Power up Power up time from r
95. nce command mode is exited auto join will re enable There are new levels of print out diagnostics that can be enabled disable with the sys print variable Ability to add prefix to HTML client post specifically the ability to append amp id and amp rtc in the HTML message DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 85 DWRN171 XX User Manual Lc DATASPHERE more than distribution datasphere wireless Systems amp Solutions GmbH Mollenbachstrasse 23 71229 Leonberg Germany 49 7152 9266930 www dataphere eu Copyright 2011 datasphere All rights reserved datasphere is a registered trademark of datasphere Apple Inc iPhone iPad iTunes Made for iPhone are registered trademarks of Apple Computer datasphere reserves the right to make corrections modifications and other changes to its products documentation and services at any time Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete datasphere assumes no liability for applications assistance or customer s product design Customers are responsible for their products and applications which use datasphere components To minimize customer product risks customers should provide adequate design and operating safeguards datasphere products
96. nd users binary data converted to ASCII hex Sample the GPIO and ADC pins and format to ASCII hex Appends amp id lt value gt where value is the device ID string that was set using set opt device lt string gt Appends the following key value pairs to the HTTP message amp rtc lt time gt amp mac lt address gt amp bss lt access point address gt amp bat lt battery voltage amp io GPIO in hex amp wake lt wake reason amp seq sequence value where time is the realtime clock value in the message as a 32 bit hex value in format aabbccddeeff and sequence value is a rolling counter of how many web posts have been sent Default 0x00 Example set opt format lt get example gt The module automatically sends an HTML header based broadcast interval set opt replace lt char gt This command sets the replacement character you use to indicate spaces in the SSID and pass phrases where lt char gt is a single character Each occurrence of the replacement character is changed into a space Only the DWRN171 XX command parser uses this replacement character Default S 0x24 Example set opt replace Sets the replacement character to DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 18 AN DATASPHERE DWRN171 XX User Manual more than
97. new baud rate immediately the host may see the AOK string at the new baud rate Depending on the baud rate it takes at least ten times the bit rate for the module to issue the first character Default Not applicable Example set uart instant 19200 Sets the baud rate to 19 200 baud DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 24 AN DATASPHERE DWRN171 XX User Manual more than distribution set uart raw lt value gt This command sets a raw UART value where lt value gt is a decimal number representing the baud rate You use this command to set non standard baud rates The lowest possible baud rate is 2 400 Using non standard raw baud rates with hardware flow control can be more useful at speeds as the microcontroller interfaced to the module may be able to better match the UART speeds and get better results lt Not sure how to rewrite this sentence something s missing after speeds gt Table 9 shows the supported raw baud rates Table 9 Supported Raw Baud Rates Raw Baud Rate Comment 458 333 This is 460 800 500 000 Raw baud rate 550 000 Raw baud rate 611 111 Raw baud rate 687 599 Raw baud rate 785 714 Raw baud rate 916 667 This is 921 600 1 100 000 Raw baud rate Default Not applicable Example set uart raw 7200 Sets the baud r
98. nsor inputs occur or at power up and removed upon power down and sleep e Added a new FTP client mode to get and put files to a FTP server Files retrieved from the server are sent over the UART and files created from the UART are stored on the FTP server e Anew scan output format is implemented in addition to the default output format This new microprocessor friendly format makes string processing of the scan output very easy e Anew UART heartbeat feature is implemented to notify the embedded microprocessor of the state of the DWRN171 XX module The heartbeat message is sent over the UART when the DWRN171 XX module is in data mode and not connected to any remote host DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 84 DWRN171 XX User Manual AN DATASPHERE more than distribution Fixed a bug in the set uart instant lt value gt command wherein the DWRN171 XX module would not return an AOK over telnet Now when this command is issued it returns an AOK over Telnet and does not exit command mode Enabled scanning for wireless networks remotely when in ad hoc mode When the scan command is issued ad hoc is temporarily disabled and results of the scan are sent over telnet The behavior of the auto connect timer has changed Added the ability to set RTC from console Added a feature wherein the mo
99. ode you can configure the network settings Remote Configuration Using Ad Hoc Mode Using ad hoc mode to configure the device eliminates the need for the module to be associated with a network access point In ad hoc mode the module creates its own on demand network to which you can connect via your computer as you would with any other network To enable ad hoc mode using hardware set GPIO9 high 3 3 V at power up For the DWRN171 XX GPIOO9 is on pin 20 look the datasheet Upon power up with GPIO9 high the DWRN171 XX module creates an ad hoc network with the following settings SSID DWRN171 XX GSX XX where XX is the final two bytes of the devices MAC address Channel 1 DHCP Off IP address 169 254 1 1 Netmask 255 255 0 0 With the ad hoc jumper in place these settings override any saved configuration settings From your computer connect to the DWRN171 XX GSX XX network This open network does not require a pass phrase or pass key Currently the DWRN171 XX module only supports OPEN mode for creating ad hoc networks It may take a few minutes for Windows to assign an IP address and connect to the network You can check your computer s IP address by running the ipconfig command in the Command Window If connected this command displays the your computer s IP address and netmask DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu
100. ommand mode and set the commands reported below set comm idle 2 set comm remote 0 save reboot To disable the Web Server OEM connect to ground the pin 5 WEB E of the module see datasheet of DW RN 171 XCW If the Web Server OEM is disabled it is possible to use RN 171 module independently DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 74 AN DATASPHERE DWRN171 XX User Manual more than distribution Associate with a secure network To associate with a secure network you must include the network password The WiFly module determines the security type automatically For example if the ssid of the network is roving1 and the pass is rubygirl In this case enter in command mode and type set wlan ssid roving1 set wlan pass rubygirl save reboot by default is enabled DHCP Then at reboot we have the information reported in fig 1 Figure 1 Connect to a Secure Network e The OEM WEBSERVER is not multithread it can serve only one request at a time e After each request or submit action wait for about 2 sec for the next action this is the time when the TCP socket is completely closed e Place the XCW WiFi module where the strength of the signal of your WiFi network is good otherwise the data transmitted by the XCW can be corrupted and bad web page will be displayed
101. onverted to ASCII set q sensor OxFF Set the sensor mask to sample all channels save Save the configuration in the config file reboot Reboot so that the settings take effect After issuing these commands the web server returns a 200 OK message as shown in Fehler Verweisquelle konnte nicht gefunden werden Figure 14 Figure 14 Server Response 200 OK response form server ICHD OPENMHTTPAI lt gt Date Mon AP SGT 23 56 46 GMT TUM fipache nod fcgid 2 3 5 mod auth passthrough 2 1 mod bulimited 1 4 FrontPage 5 8 2 W Pouered By PHP S 2 13 onnection close ontent Type text htnm D 1233BD1 73C408483DB83F8E06D797B930C630CED data Data in the GET string Sensor Data DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support 2datasphere eu 57 AN DATASPHERE DWRN171 XX User Manual more than distribution HTML Client Example Posting UART Data to a Web server The module can post serial UART data in ASCII or binary format automatically In this example when the serial UART data comes in the module connects and sends data to the web server in the following format GET server php value lt user serial data gt n n Use the following commands to set the parameters set ip proto 18 Turn on HTTP mode 0x10 and TCP mode Ox2set dns name www rovingnetworks com Set the we
102. ork SSID contains spaces use a instead of the space e g MYSNETWORK to represent My Network Default Not applicable Example To join an unsecure network join roving1 Join the network roving1 To join a secure network set wlan pass rubygirl Set the password to rubygirl join roving1 Join the network roving1 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 34 AN DATASPHERE DWRN171 XX User Manual more than distribution join lt value gt Use this command to join a network that is shown in the scan list where lt value gt is the entry number listed for the network in the scan list If network is security enabled you must set the passphrase with the set wlan phrase command prior to issuing the join command Example join 1 Join the network indicated by a 1 in the scan list leave This command disconnects the module from the access point to which it is currently associated Example leave Disconnect from the access point lites This command causes the LEDs on the RN 134 evaluation board and RN 370 DWRN171 XX serial adapter to blink Using this command a second time stops the blinking lt does this command apply to the RN 174 gt Example lites The LEDs begin blinking lookup lt string gt This command causes the module to perform a DNS query where lt string
103. pen 100 1 n open network use the join command to associate with the access point The scan list in Figure 12 shows that roving1 is an open access point Type join roving1 or join 1 to associate with the network as shown in Figure 13 Figure 13 Join the Network 2 03 join rovingi Auto Assoc rovingi chan 1 mode zOPEN SCAN OK 2 03 Associated DHCP in ims Renew 86400 s P ON 10 20 20 62 2000 255 255 255 0 RP RTEEONU indz 10 isten FAIL I D I N G H p M b 1 H If the access point is secure you must set the pass phrase prior to issuing the join command The module attempts to inquire and determine the access point s security protocol you do not need to set the authentication mode To set the WPA pass phrase use the set wlan phrase lt string gt command For WEP set the key using the set wlan key lt value gt command Once the module has joined the network successfully it stores the access point s SSID You can save the SSID and the pass phrase to the configuration file so that the module can associate with the access point each time it boots Making Connections To connect to the module open an IP socket and connect to the module s IP address You can use Telnet to test the connection type open lt address gt lt port gt in a Telnet window After the connection is open you can type characters into the UART window and see them on the Telnet window or vise versa Example Open a Conn
104. r where lt value gt is a decimal number from 0 to lt get max gt representing milliseconds When this configuration option is set the module sends an IP packet if no additional bytes are received for lt value gt ms Setting this value to 0 disables forwarding based on the flush timer The flush timer is one of three available methods you can use to control TCP IP packet forwarding The others are set comm match and set comm size For more information refer to UART Receiver amp RTS CTS Hardware Flow Control UART Receiver on page 42 Default 10 Example set comm time 20 Set the flush timer to 20 ms set dns address lt address gt This command sets the IP address of the DNS sever where lt address gt is an IP address in the form lt value gt lt value gt lt value gt lt value gt with lt value gt being a number between 0 and 255 This address is automatically set when using DHCP you must set the DNS IP address for static IP or automatic IP modes Default 0 0 0 0 Example set dns address 169 64 1 1 Set the DNS server address to 169 64 1 1 set dns name lt string gt This command sets the name of the host for TCP IP connections to lt string gt where lt string gt is up to 32 characters Default server1 Example set dns name roving1 Set the DNS host name to roving1 set dns backup lt string gt This command sets the name of the backup host for TCP IP connections to lt string gt where lt string gt i
105. re wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 65 AN DATASPHERE more than distribution DWRN171 XX User Manual Firmware versions 2 23 and higher support the set q power lt value gt command This command sets an 8 bit register with two 4 bit nibbles that automatically turns on the sensor power See set q power lt value gt on page 19 for more details on using this command Example lt insert example gt DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 66 AN DATASPHERE DWRN171 XX User Manual more than distribution DEFAULT CONFIGURATION FIRMWARE VERSION 2 28 This section describes the default configuration settings for firmware version 2 28 and how to restore them ADHOC PARAMETERS Beacon 100 milliseconds Probe 5 Seconds to look for beacons before declaring ad hoc is lost Reboot O Unused parameter for future development Leave at default value BROADCAST PARAMETERS IP address 255 255 255 255 Port 55555 Interval 7 seconds COMM PARAMETERS Close string Open string Remote string Flush size Match character Flush timer Idle timer Cmd char OPEN CLOS HELLO 64 0 10 milliseconds 0 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wirele
106. rmany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 30 AN DATASPH ERE DWRN171 XX User Manual aa 2 Example get broadcast Show broadcast UDP information get com This command displays the communication settings Example get com Show communication settings get dns This command displays the DNS settings Example get dns Show the DNS information get everything This command displays all of the configuration settings which is useful for debugging Example get everything Show all configuration settings get ftp This command displays the FTP settings Example get ftp Show the FTP setttings get ip lt char gt This command displays the IP address and port number settings where lt char gt is the optional parameter a Using lt char gt returns the current IP address Example getipa Display the current IP address get mac This command displays the device s MAC address Example get mac Show the MAC address get option This command displays the optional settings such as the device ID Example get option Show the optional settings get sys This command displays the system settings sleep and wake timers etc Example get sys Show the system settings get time This command displays the time server UDP address and port number DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems
107. ry and redundancy If the host s first IP address connection fails the module uses the backup IP if set If this fails or is not set the module uses the first DNS name If this fails or is not set the module uses the backup DNS name if set Example Set the Backup IP Address set ip backup lt address gt Set the backup IP address Example Set the Backup DNS Name set dns backup lt string gt Set the backup host name USING THE HTML CLIENT FEATURE The module has a built in HTML client When enabled the module can get or post data to a web server For example you can use the HTML client to post serial and or sensor data to the host web server This feature makes possible to provide Wi Fi capabilities to applications such as GPS units remote sensors weather stations etc Example Retrieve Web Server Data In this example you want to retrieve data from the web server with the format http www webserver com ob php obvar WEATHER To perform this function use the following settings set ip proto 18 Enable the HTML client set dns name www webserver com Set the web server name set ip address 0 Turn on DNS set ip remote 80 Set the web server port 80 is standard set com remote 0 Turn off the REMOTE string so that it does not interfere with the post To make the connection use the open command or you can use open www webserver com 80 The user s microprocessor writes the following string to
108. s the server reply with the home page reported in figure 2 To have the response XML we have to use the GET parameter format how is shown below 192 168 2 66 2000 format xml Following is reported all the GET parameters supported format lt cmd gt cmd html response HTTP cmd xml response XML example 192 168 2 66 2000 format xml web server response XML title lt cmd gt cmd offt don t show the title WEB SERVER OEM v2 0 in the web page fig 2 cmdzont show the title WEB SERVER OEM v2 0 in the web page fig 2 example 192 168 2 66 2000 title offt no title is shown DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support 2datasphere eu 71 AN DATASPHERE DWRN171 XX User Manual more than distribution if not used this GET parameter the title is shown outi cmd cmdzon1 output 1 pin with label OW1 goes High 3 3Volt cmd off1 output 1 pin with label OW1 goes Down OV example 192 168 2 66 2000 out1 0n1 OW1 goes High out2 lt cmd gt cmd on2 output 2 pin with label OW2 goes High 3 3Volt cmd off2 output 2 pin with label OW2 goes Down 0V example 192 168 2 66 2000 0ut2 0n2 OW2 goes High out3 lt cmd gt cmd on3 output 3 pin with label OW3 goes High 3 3Volt cmd off3 output 3 pin with label OW3 goes Down OV example 192 168 2 66 2000 out3 0n3 OW3 goes High out4 lt cmd gt
109. s to the module you send a keyword followed by optional parameters Commands are case sensitive and you cannot use spaces in parameters Use a to indicate a space e g MY NETWORK should be written as MY NETWORK Hex input data can be uppercase or lowercase String text data such as the SSID is case sensitive You can use shorthand for the parameters For example the following commands are equivalent e set uart baudrate 115200 e set uart b 115200 e setu b 15200 NOTE You cannot use shorthand for command keywords For example s uart baudrate 115200 is illegal You can type numbers in decimal e g 115200 or hexadecimal To enter a number in hex use Ox value For example the hex value FF would be entered as OxFF COMMAND ORGANIZATION There are five general command categories as shown in Table 1 Table 1 Command Types Command Type Description Set commands Set commands take effect immediately and are stored to memory when the save command is issued Get commands These commands retrieve the stored information and display it Status commands These commands display the interface status IP status etc Action commands Use these commands to perform actions such as scanning connecting disconnecting etc File I O commands Use these commands to upgrade load and save configuration delete files etc NOTE You must save any changes you make using the save command or the module will load the previous
110. s up to 32 characters Default backup2 Example set dns backup roving2 Set the DNS host name to roving2 set ftp addr lt address gt This command sets the FTP server s IP address of the FTP server where lt address gt is an IP address in the form lt value gt lt value gt lt value gt lt value gt with value being a number between 0 and 255 The default is the datasphere FTP server 208 109 78 34 port 21 Default 208 109 78 34 Example set ftp addr 66 35 227 3 Set the FTP server to 66 35 227 3 set ftp dir string This command sets the starting directory on the FTP server where string is up to 32 characters To read write to subfolders use the V character To indicate the root directory use a period Default public DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 13 AN DATASPH ERE DWRN171 XX User Manual meret Aeon Example set ftp dir demo Sets the FTP server starting directory to demo set ftp dir demo test Sets the FTP server starting directory to demo test set ftp dir Sets the FTP server starting directory to the root directory set ftp filename lt filename gt This command sets the name of the file that is transferred when issuing the ftp u command where lt filename gt is the firmware image If you specify any file other than the firmware ima
111. settings upon reboot or power up When the system boots all configuration data is loaded into RAM variables from the config file The set commands only modify the RAM copy of the system variables In general the IP WLAN and UART settings require you to save and reboot before they take effect because they operate upon power up For example you only associate set the channel and obtain an IP address once at power up Most of the other commands e g COMM settings and timers take effect immediately allowing you to change parameters on the fly minimizing power usage and saving flash re write cycles DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 9 AN DATASPHERE DWRN171 XX User Manual more than distribution Once configuration is complete you must save the settings to store the configuration data otherwise it will not take effect upon reboot or reset You can store multiple configurations using the save lt filename gt command and you can load them using the load lt filename gt command SET COMMANDS These commands begin with the set keyword and include the categories shown in Table 2 Table 2 Set Commands Parameter Description adhoc Controls the adhoc parameters broadcast Controls the broadcast hello heartbeat UDP message comm Sets the communication
112. sing the UART or over the air using ad hoc mode This section describes how to configure the module over the UART using the RS 232 connector or an evaluation board For this mode open a terminal emulator on the COM port associated with the module The default baud rate is 9 600 8 bits and no parity To configure using ad hoc mode refer to Adhoc Networking Mode on page 63 Once in ad hoc mode open a telnet window using the IP address 169 254 1 1 port 2000 Associate with an Access Point From within the terminal window put the module into command mode by typing The module responds with CMD indication that it is in command mode Type show net to display the current network settings as shown in Figure 11 Figure 11 Display Current Network Settings s S C A D Ti Li lt DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 51 AN DATASPHERE DWRN171 XX User Manual more than distribution Find all available networks with the scan command as shown in Figure 12 Figure 12 Find Available Networks a lt 2 03 gt SCAN Found 6 If yoy m SSID Ch RSSI Sec i are roving 1 4 Open Q0 1c df 4f 45 4 NETGEAR O1 Open 1 22 3f 6b 95 42 104 7 conn 7FX12018434 Q6 73 EP 18 3a 7e 71 7 ectin TheLoft 6 51 WPAZPSK M AES 1100 7 airlink 11 11 53 WPAv1 PM TKIP 3100 ac gto sensor 11 52 O
113. sion 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 272 AN DATASPHERE DWRN171 XX User Manual more than distribution KNOWN PROBLEMS The firmware has the following known issues e The UART does not support odd or even parity it only supports no parity Flow control RTS may fail to de assert quickly enough for some high speed CPUs to stop sending data bytes correctly For high speed transfers at baud rates greater than 460 800 datasphere recommends limiting the RX data to the maximum Ethernet frame 1 460 bytes and using a protocol to acknowledge that the remote host receives the data DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 73 AN DATASPHERE DWRN171 XX User Manual more than distribution APPENDIX A USER MANUAL WEB SERVER OEM V2 0 Basic Configuration of RN 171 for WEB SERVER OEM The module RN 171 is by default configured with this parameter set comm idle 2 set comm remote 0 sets the Idle Timer Value This is the number of seconds with no transmit or receive data over TCP before the connection is closed automatically Very important If it is used the Factory Reset input to restore the default configuration of RN 171 To configure the Web Server OEM it needs to enter in c
114. sleep You can wake the module by sending characters over the UART or by using the wake timer Example sleep Put the module to sleep time This command sets the real time clock by synchronizing with the time server specified with the time server set time parameters This command sends a UDP time server request packet Example time Set the real time clock FILE I O COMMANDS You use the file I O commands to save load delete and update configuration and other files del string value This command deletes a file where string is the filename and value is an optional number that overrides the name and uses the sector number displayed by the Is command Example del my old config Delete the file my old config DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 36 AN DATASPHERE DWRN171 XX User Manual A load lt string gt This command reads in a new configuration file where lt string gt is the filename Example load my_config Load the file my_config Is This command displays the files in the system Example Is Display the files in the system save lt string gt This command saves the your configuration settings to a file where lt string gt is an optional filename If you do not specify a filename the module saves the settings to a file named con
115. ss Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 67 AN DATASPHERE DWRN171 XX User Manual more than distribution DNS PARAMETERS IP address Name Backup FTP PARAMETERS 0 0 0 0 server1 backup2 Server address File User Password Dir Timeout FTP_mode IP PARAMETERS 208 109 78 34 datasphere default update server port 21 wifly GSX img for RN 131 use wifly EZX img for the RN 171 roving Pass123 public 40 0x0 DHCP IP address Net mask Local port Gateway Host Remote port ON 1 enabled 0 0 0 0 255 255 255 0 2000 0 0 0 0 0 0 0 0 2000 Protocol 2 TCP server and client MTU 1524 Flags 0x7 TCP mode 0x0 Backup 0 0 0 0 OPTIONAL PARAMETERS Device ID DWRN171 XX GSX Join timer WPA timer 1000 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 68 AN DATASPHERE DWRN171 XX User Manual i dpa Replacement char 0x24 Format 0x00 Password no password enforced Signal 0 Average 5 SYSTEM PARAMETERS Sleep timer 0 Wake timer 0 Trigger Ox1 SENSO pin wakes up the device Auto connect 0 lOfunc 0x0 No alternate functions lOmask Ox20FO0 for RN 131 Ox21FO for RN 171 lOvalue 0x0 Print level Ox1 Print enabled Debug Register 0x0 Unused parameter for futur
116. ster in ad hoc parameters This register is reserved for future development and should not be used Please leave it to default values e Added a new debug register in the system parameters This register is reserved for future development and should not be used Please leave it to default values VERSION 2 27 09 08 11 e Added support for Wi Fi Protected Setup WPS push button mode e Added support for WEP64 encryption e Added support for backup IP address e Added a new TCPMODE register to control TCP connect timers force DNS and remote configuration e Added new bit in UART mode register bit 5 in which replaces the lt 2 23 gt r n in console with the replace character e Fixed the FTP file put mode so it over rides HTTP mode In version 2 23 if HTTP protocol is set and or option format is set extra data would be added to FTP put file data This has been fixed in version 2 28 e Fixeda bug where if the TCP CLIENT mode is set the module would randomly attempt outgoing connections e Fixeda bug in FTP data write mode whereby sometimes the OPEN status string came back over the UART before the file transfer was actually ready This fix also improves the speed of FTP open in write mode such that the OPEN will be faster VERSION 2 23 04 03 2011 e Created new set of sensor commands set q sensor mask and set q sensor value Also sensor power can now be configured and applied either only when sampling of se
117. successful update FL SIZ FLAGS 11 18 3 DWRN171 XX_GSX 2 20 29 1 10 config 30 18 3 DWRN171 XX_GSX 2 21 208 Free Boot 30 Backup 11 After downloading the firmware checks the image and compares it to the stored values in the file before committing the image to flash and updating the boot record If the checksum fails the module displays UPDATE FAILED x and deletes the image NOTE You must reboot or power cycle the module to use the new firmware To boot with different firmware use the command boot image lt value gt which sets the current boot image as lt value gt For example to boot the previous image using the previous example lt 2 20 gt boot image 11 Set Boot Image 11 OK FTP CLIENT In addition to downloading firmware via FTP with firmware version 2 22 and higher the module can get and put files to an FTP server Connect to an FTP Server By default the module is configured to download the latest firmware from the datasphere FTP server To configure the module to connect to your own FTP server you must adjust the parameters as described in the example below Example Connect to an FTP Server set ftp address lt address gt Set FTP server s IP address Default is 208 109 78 34 set ftp dir lt string gt Set the directory in the FTP server Default is public set ftp user lt string gt Set the user name set ftp pass lt string gt Set the password save Save the settings reboot
118. sussucsessecsesnecuccussucsussucaesnessesussussussussessesaeenesussessesaeeaeeateneeneseeeees 51 Making Connections c ccccssssssssssssessssssssesscsesscsessssessssessssesssseenssesucsesussesussesuesesussesussesussessesesussesussesussesussesesseauesesessesusaeeeeaeaneaeeeesees 52 Setting up Automatic Connections ccecsesessesessessssesessessssessssessssessssessssesussessssesussessssesussesnssesssseenssesussesnssesesseesssesesseensaeensseeneaeess 53 Controlling Connections using GPIO5 amp GPIOG eecessssssssssssessssessesessesessesessesussesucsesuesesucsesussesucsesssseseesesuesesecsesssesesseaeaeeeaees 53 Using DNS SettilIgS ius EEUU HERES REO ESTARIA OT EGRE RENDERE VOIR IRURE 53 Using the Backup IP Address Connect Function ccccessssssssssessessessessessesscsucsucsucsecsessessesscaucsucsussecsessecssssesucsucaeesecseesseneessaneanees 54 Using the HTML Client Feat re riter ERE HEATERS ETRAS e RC GEA FE ERAS EROSIE 54 Built In HTML Client Modes essent tnter tette tenete tete tn tette tete te tn tet nte te tete tettetentet 54 Connect to a Web Server Automatically esistente ttn tette tete tti te tete ttti tt tetti tette tease saints aas 55 Connect to a Web Server Automatically when UART Data Is Received essent 55 PostBiliabyJDatd seo n EROR ERRORI IHREN RII HII IURI 56 Post Sensor Data Automatically c eececsssessssessssecsssessssesscseescsessssessssessssessssessssessssesu
119. t always respond to probes If you do not set this parameter there is no way to detect that an access point is no longer present until it becomes available again if ever Default 0 disabled Example set wlan linkmon 5 Set the number of scan attempts to 5 set wlan mask mask This command sets the WLAN channel mask which is used for scanning channels with auto join policy 1 or 2 where mask is a hex number bit O channel 1 This setting is used when the channel is set to 0 You can specify input for this command using decimal or hex prefixed with Ox DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 28 AN DATASPH ERE DWRN171 XX User Manual moe ae Default Ox1FFF all channels Example set wlan mask need example need desc set wlan num value This command sets the default WEP key where value is 1 to 4 Default need default Example set wlan num 2 Sets the default key to 2 set wlan phrase string This command sets the passphrase for WPA and WPA2 security modes where lt string gt is 1 to 64 characters The passphrase is alphanumeric and is used with the SSID to generate a unique 32 byte pre shared key PSK which is then hashed into a 256 bit number When you change either the SSID or the passphrase the module re calculates and stores the P
120. t uses passive mode FTP which allows operation through firewalls and the Internet To connect to datasphere to obtains the latest released firmware use the following settings FTP username roving FTP password Pass123 FTP filename wifly GSX img RN 131 or wifly EZX img RN 171 FTP directory public this parameter cannot be modified NOTE Before using FTP to upgrade the firmware the module must first be associated with an access point that is connected to the Internet To update the firmware issue the command ftp update lt string gt where lt string gt is an optional filename use the optional name to bypass the default firmware file name The module retrieves the file and switches the boot image to the new file resulting in the following messages DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 58 AN DATASPHERE DWRN171 XX User Manual more than distribution lt 2 20 gt ftp update lt 2 20 gt FTP connecting to 208 109 78 34 FTP file 30 NOTE After the module reboots with the new firmware datasphere recommends that you reset the module to the factory default parameters using the factory R command Failure to do so may result in some variables being initialized with random values The previous firmware becomes the backup image The following example shows the file system after a
121. t wlan ssid my_adhoc_network set wlan chan 1 Turn off DHCP so that the module does not attempt to obtain an IP address from another device and set the module s IP address and netmask Because automatic IP assignment fixes the first two bytes of the IP address use 255 255 0 0 as the netmask so that other devices connecting to the module can be reached You can also set the netmask to a smaller subnet if the other device s IP addresses begin statically at the same subnet as the ad hoc device set ip address 169 254 1 1 set ip netmask 255 255 0 0 set ip dhcp 0 Save your configuration and reboot The module will be in ad hoc mode The module can associate with an ad hoc network created by another device Type the commands set wlan ssid my_adhoc_network save reboot To associate with an ad hoc network without saving the changes to the module s flash memory use the join command e g join my_adhoc_network lt cr gt If the module was already associated with another network you must first disassociate with it using the leave command If DHCP is enabled the DWRN171 XX device obtains an IP address automatically when it associates with the ad hoc network By definition auto IP sets the first two bytes of the subnet to 169 254 xxx xxx The DWRN171 XX device requires 2 to 3 seconds to resolve the IP address To set the IP address statically disable DHCP and explicitly assign the IP address set ip dhcp 0 set ip address 169 254 1 2
122. ter the module has associated authenticated and has an IP address 5 GPIO5 Input Set this pin high to trigger a TCP connection and low to disconnect DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 44 AN ee ERE DWRN171 XX User Manual i VET 6 GPIO6 Output This pin goes high when the module is connected over TCP and low when disconnected NOTE Bits 0 3 are mutually exclusive with bits 4 6 i e 0x77 is an illegal value If you disable the LEDs using bits O 1 and 2 you can then use the show i command to read these GPIO pins For example the show i command might return Port 30 To use the alternate LEDs functions use the following commands set sys iofunc 0x70 Enable alternate function for GPIO4 6 save Store configuration reboot Reboot the module Controlling Connections with GPIO Pins In embedded applications it is useful to monitor and control the status of the TCP IP connection To monitor and control the module s connection status enable the alternate function of GPIOA 6 Using the alternate function for these GPIO pins the module connects to the stored remote host IP address and port when GPIOS5 is driven high and disconnects when driven low You can monitor the TCP IP connection status by reading GPIO6 it is high when connected and low
123. ts the port to which the UDP heartbeat is sent to 55555 set comm char This command sets character used to enter command mode to char You typically use this setting when the default string used to enter command mode is a possible data string You must carefully note the new character After you save this setting upon every subsequent reboot the module ignores and looks for char char char to enter command mode Default Example set comm w Sets the string to enter command mode www set comm close lt string gt This command sets the ASCI string that is sent to the local UART when the TCP port is closed where string is one or more characters up to a maximum of 32 If you do not wish to use a string use a zero 0 as the string parameter Default CLOS Example set comm close port closed Set the string to port closed set comm open string This command sets the ASCI string that is sent to the local UART when the TCP port is opened where string is one or more characters up to a maximum of 32 If you do not wish to use a string use a zero 0 as the string parameter Default OPEN DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu zb AN DATASPHERE DWRN171 XX User Manual more than distribution Example set comm open port open
124. ul the WPS application quits and the module reboots If the module is set to use the standard GPIO functions i e not the alternate GPIO4 functions the green LED blinks once per second If the alternate GPIO4 function is enabled the green LED goes high Scan Output Format Showing WPS Enabled Access Point The scan output shows access points that support the WPS feature As shown in Figure 17 access points that support WPS are listed with WPSPB in the security suites Figure 17 Access Points Supporting WPS in Scan List d CONS Tera Term VT File Edit Setup Control Window Help 2 27 CAN Found 7 um SSID Ch RSSI Sec MAC Address Suites 1 g2 01 67 WPA2PSK 88 15 f9 38 bd bB AESM AES 3184 2 SensorNet 81 58 WPA2PSK 88 22 3f 65 95 42 AESM AES UPSPB 1188 3 rovingi i 58 WPA2PSK e 91 5 57 a3 54 AESM AES 3188 4 Belkin 40E9 86 3 WPA2PSK 94 44 52 97 20 e9 AESM AES WPSPB 1104 5 linksys 86 76 Open 88 1e e5 67 73 b1 WPSPB 184 6 default 806 76 Open 88 18 082 70 7e e8 WPSPB 2100 portthru 18 52 Open 42 2b fd 48 d4 8e Adhoc 208 If you press the WPS button on the access point and then perform a scan the scan returns a A to indicate the access point is in WPS active mode See Figure 18 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 62 AN
125. ut2 Sout3 Sresult params out3 Sout4 Sresult params out4 Ssens1 Sresult params sens1 Ssens2 Sresult params sens2 Ssens3 Sresult params sens3 Ssens4 Sresult params sens4 Sscale1 Sresult params scale1 scale2 Sresult params scale2 scale3 Sresult params scale3 Sscale4 Sresult params scale4 echo Stitle echo Sout1 echo Sout2 echo Sout3 echo Sout4 echo Ssens1 echo Ssens2 echo Ssens3 echo Ssens4 echo Sscale1 DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 82 AN DATASPHERE more than distribution DWRN171 XX User Manual echo Sscale2 echo Sscale3 echo Sscale4 gt the File xmlpars php is possible download from web page of the documentation of the DW RN171 XCW DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 83 AN DATASPHERE DWRN171 XX User Manual more than distribution CURRENT FIRMWARE FEATURES amp FIXES VERSION 2 30 10 26 2011 e Added support for incorrect WPA modes namely WAPv1 with AES encryption and WPAv2 with TKIP encryption e Added support for WEP shared mode e Increased FTP filename size to 64 bytes e Added a new reboot regi
126. verter range 0 3 3V By default scale3 1 then we have fora voltage on sensor3 of 3 3V the value 1023 000 shown in the web page section SENS3 If we want to show 3 3 V in the section web page SENS3 we have to change the scale value with 0 00322 example 192 168 2 66 2000 scale3 0 00322 scale4 lt cmd gt cmd is a scale coefficient of proportionality for sensor 4 range 0 0001 9 The sensor 4 input is an analog input with 10 bit ADC converter range 0 3 3V By default scale4 1 then we have for a voltage on sensor4 of 3 3V the value 1023 000 shown in the web page section SENS4 If we want to show 3 3 V in the section web page SENS4 we have to change the scale value with 0 00322 example 192 168 2 66 2000 scale4 0 00322 Multiple GET parameter To send multiple GET parameter use this example to activate the OUT1 deactivate the OUT2 and set the scale1 0 34 we have to type on browser 192 168 2 66 2000 0ut1 0n1 amp o0ut2 0ff2 amp scale1 0 34 And so on for all the parameters DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 79 E DATASPHERE DWRN171 XX User Manual more than distribution WEB PAGE to control outputs and read sensors Connecting via web browser at the address of web server in our example 192 168 2 66 2000 we have the web page of figure 3 Figure 3 Web Server Home page
127. y IP address is assigned and overwritten when the module associates with the access point Default 0 0 0 0 Example set ip gateway 169 254 1 1 Sets the IP gateway to 169 254 1 1 set ip host lt address gt This command sets the remote host s IP address where lt address gt is an IP address in the form lt value gt lt value gt lt value gt lt value gt with lt value gt being a number between 0 and 255 You use this command to make connections from the DWRN171 XX module to a TCP IP server with the IP address lt address gt Default 0 0 0 0 Example set ip host 137 57 1 1 Sets the remote host s IP address to 137 57 1 1 set ip localport value This command sets the local port number where value is a decimal number representing the port DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 16 AN DATASPH ERE DWRN171 XX User Manual ip 2 Default 2000 Exampl set ip localport 1025 Sets the local port to 1025 set ip netmask address This command sets the network mask where address is an IP address in the form lt value gt lt value gt lt value gt lt value gt with value being a number between 0 and 255 If DHCP is turned on the netmask is assigned and overwritten when the module associates with the access point Default 255 255 255 0 Example set ip n
128. y module is instructed to open a TCP IP CIPIOS cam by SSL SITES connection to the stored remote host This signal instructs the microprocessor that the TCP connection is open andit can begin sending receiving data over the TCP link To close the conenction the microprocessor drives GPIO5 low Event The WiFly module successfully opens the GPIO6 High by WiFly Module TCP connection to the stored remote host DW RN171 XX User Manual Revision 1 1 Printed in Germany by datasphere wireless Systems amp Solutions GmbH All rights reserved www datasphere eu support datasphere eu 45 AN DATASPHERE DWRN171 XX User Manual more than distribution SETTING DEBUG PRINT LEVELS You can enable print functions to assist with debugging the operation and status of the module The set sys printlvl value command controls these additional print functions where lt value gt is a bit mapped register that controls which printout messages are sent to the UART See set sys printlvl lt value gt on page 21 for more information Scan Output Format Firmware version 2 22 and higher supports a comma delimited scan output format which a microprocessor can use to parse the RSSI information The scan command output format is Row Count Channel RSSI Value dBm Security Capabilities Access Point MAC SSID Mode Address You enable the scan format using the set sys printlvl 0x4000 command The scan comm
129. ys wake 90 The module wakes after sleeping for 90 s save Save the settings reboot Reboot Figure 7 shows the transitions between the sleep and awake state based on the sleep and wake timer settings in the previous example Figure 7 Sleep amp Awake State Transitions Awake State Sleep State E M gg Sleep Timer Wake Timer Sleep Timer 30s 90s 30s UDP Sleep amp Connection Timers In UDP only protocol mode set with the set ip proto 1 command the autoconn timer is used as an auto sleep timer When the module begins to transmit the first UDP data packet this timer begins counting down When it reaches 0 the module sleeps You set the UDP auto sleep timer using two commands set sys autosleep and set comm timer The timer interval is a product of the autosleep value and the comm flush timer in ms The timer is decremented every product milliseconds For example if you want a UDP sleep timer of 40 ms use the following commands set sys autosleep 4 Set the auto sleep value to 4 set comm timer 10 Set the comm timer to 10 ms default value The resulting UDP sleep timer is 4 x 10 ms or 40 ms You could also set autosleep 2 and comm timer 20 ms to achieve the same effect datasphere recommends using a minimum value of 2 when the default flush time is 10 ms to ensure that the UDP packet is transmitted For larger packets you should increase the value TCP Connection Tim