Wireless AP Controller with 8-Port 802.3at PoE+ WAPC
Contents
1. 3 At the prompt enter the following command and press Enter as shown in Figure 5 2 The previous command would apply the following settings for the AP Controller 7 Press ENTER to get started WAPC 1232HP configure terminal WAPC 1232HP config interface vlan 1 WAPC 1232HP config if vlan ip address 192 168 1 100 255 255 255 0 Figure 5 2 IP Address Screen 4 Repeat step 1 to check if the IP address is changed W Store current configuration 5 At the prompt enter the following command and press lt Enter gt copy running config startup config Press ENTER to get started sername admin WAPC 1232HP configure terminal NAPC 1232HP config interface vlan i WAPC 1232HP config if vlan ip address 192 168 1 100 255 255 255 0 NAPC 1232HP config if vlan NAPC 1232HP config if vlan exit NAPC 1232HP config exit NAPC 1232HP copy running config startup config Building configuration Saving 1483 bytes to flash startup config Figure 5 3 Saving Current Configuration Command Screen If the IP is successfully configured the AP Controller will apply the new IP address setting immediately You can access the Web interface of the AP Controller through the new IP address If you are not familiar with the console command or the related parameter enter help anytime in console to get the help description 6 Starting Web Management The following
2. or manage the AP Controller via console interface Please refer to the user s manual for more 7 Saving Configuration In the AP Controller the running configuration file stores in the RAM In the current version the running configuration sequence of running config can be saved from the RAM to FLASH by executing save startup config command so that the running configuration sequence becomes the startup configuration file which is called configuration save To save all applied changes and set the current configuration as a startup configuration The startup configuration file will be loaded automatically across a system reboot 1 Click System Save Startup Config IP Configuration IP Status Users Configuration Privilege Levels NTP Configuration Time Configuration UPnP DHCP Relay DHCP Relay Statistics CPU Load System Log Detailed Log Remote Syslog SMTP Configuration Web Firmware Upgrade TFTP Firmware Upgrade Save Startup Config Configuration Sownload Figure 7 1 Menu Save Startup Config 2 Press the Save Configuration button Save Running Configuration to startup config Please note The generation of the configuration file may be time consuming depending on the amount of non default configuration Save Configuration Figure 7 2 Save Startup Config 8 Recovering Back to Default Configuration W IP Address has been changed or admin password has been forgotten To res
3. Wireless AP Controller with 8 Port 802 3at PoE WAPC 1232HP Quick Installation Guide Table of Contents Package Contents aiii e ee 3 Requiremelits 2 2 e a nas 4 terminal SUD iiss dd 5 LOGON to the Console cocida ese ettet ten E send da a nah S ESAE NEA 6 Configuring IP Address ise egere trees a al 7 Starting Web Management s iu za 9 Saving ConfiglratiOnt uuucseus sedeo ena nns aan A 12 Recovering Back to Default Configuration uessesssensensnnnnnnnnnsnnnnnnnnnnnnnnn nun 13 Gusto Mmer SUPPOHE urn EE 14 1 Package Contents Thank you for purchasing PLANET Wireless AP Controller with 8 Port 802 3at PoE WAPC 1232HP AP Controller mentioned in this Guide refers to the WAPC 1232HP Open the box of the AP Controller and carefully unpack it The box should contain the following items The AP Controller x 1 Quick Installation Guide x 1 RS232 to RJ45 Console Cable x 1 Rubber Feet x 4 Two Rack mounting Brackets with Attachment Screws x 1 e Power Cord x 1 e SFP Dust Cap x 2 If any item is found missing or damaged please contact your local reseller for replacement 2 Requirements Workstations running Windows XP 2003 Vista 7 8 2008 MAC OS X or later Linux UNIX or other platforms are compatible with TCP IP protocols Workstations are installed with Ethernet NIC Network Interface Card Serial Port Connection Terminal The above Workstati
4. as Figure 6 3 shows PLANET p System AP Control AP Monitoring AP Status AP Maintenance DHCP server SNMP Port Management Link Aggregation VLANS y Spanning Tree Multicast QoS Access Control List Authentication p Security MAC Address Table p LLDP Diagnostics PoE 410 WAPC 1232HP Welcome to PLANET WAPC 1232HP Wireless AP Controller with 8 port 802 3at PoE PLANET Technology Corporation 10F No 96 Minquan Rd Xindian Dist New Taipei City 231 Taiwan R O C Tel 886 2 2219 9518 Fax 886 2 2219 9528 Email Support planet com tw Copyright amp 2015 PLANET Technology Corporation All rights reserved Figure 6 3 Web Main Screen The Menu on the left of the Web page let you access all the commands and statistics the AP Controller provides System AP Control AP Monitoring AP Status AP Maintenance DHCP server SNMP Port Management Link Aggregation VLANS Spanning Tree Multicast Qos Access Control List Authentication Security MAC Address Table LLDP Diagnostics POE Loop Protection gt RMON Figure 6 4 Menu If you are not familiar with the functions or the related param eter press Help icon anytime on the Web page to get the help description Now you can use the Web management interface to continue the AP management
5. et the IP address to the default IP Address 192 168 1 100 or reset the login password to default value press the hardware reset button on the front panel for about 10 seconds After the device is rebooted you can login the management Web interface within the same subnet of 192 168 1 xx t PoE LNK A Alert ENK 1000 A 9 LNK ACT e Y o PoE In Use Figure 8 1 Reset button 9 Customer Support Thank you for purchasing PLANET products You can browse our online FAQ resource and User s Manual on PLANET Web site first to check if it could solve your issue If you need more support information please contact PLANET support team PLANET online FAQ http www planet com tw en support faq php type 1 Wireless support team mail address support_wireless planet com tw WAPC 1232HP User s Manual http www planet com tw en support download php type1 4 amp model 48666 amp type 3 Copyright PLANET Technology Corp 2015 Contents are subject to revision without prior notice PLANET is a registered trademark of PLANET Technology Corp All other trademarks belong to their respective owners
6. ons come with COM Port DB9 or USB to RS232 converter The above Workstations have been installed with terminal emulator such as Hyper Terminal included in Windows XP 2003 Serial cable one end is attached to the RS232 serial port while the other end to the console port of the AP Controller Ethernet Port Connection Network cables Use standard network UTP cables with RJ45 connectors The above PC is installed with Web browser and JAVA runtime environment plug in It is recommended to use Internet Explorer 8 0 or above to access the AP Controller If the Web interface of the AP Controller is not accessible please turn off the anti virus software or firewall and then try it again 3 Terminal Setup To configure the system connect a serial cable to a COM port on a PC or notebook computer and to the RJ45 type of the console port of the AP Controller PC Workstation with Terminal Emulation Software AP Controller RS232 to RJ45 Cable c Serial Port Figure 3 1 AP Controller Console Connectivity A terminal program is required to make the software connection to the AP Controller 1 Run terminal program on the OS 2 When the following screen appears make sure that the COM port should be configured as COMT Properties Port Settings Baud 115200 Bits per second i y Data bits 18 Data bits 8 Parity None Stop bits td Stop bits Flow c
7. ontrol None Elow control v Figure 3 2 COM Port Configuration 5 e 4 Logon to the Console Once the terminal is connected to the device power on the AP Controller and the terminal will display running testing procedures Then the following message asks to log in user name and password The factory default user name and password are shown as follows and the login screen in Figure 4 1 appears Username admin Password admin Press any key to continue admin Passwerd WAPC 1232HP Figure 4 1 AP Controller Console Login Screen The user can now enter commands to manage the AP Controller For a detailed description of the commands please refer to the following chapters 1 For security reason please change and memorize the new pass word after this first setup 2 Only accept command in lowercase letter under console inter face 5 Configuring IP Address The AP Controller is shipped with default IP address shown below To check the current IP address or modify a new IP address for the AP Controller please use the procedures as follows B Show the current IP Address 1 At the prompt enter show ip interface brief 2 The screen displays the current IP address as shown in Figure 5 1 Press ENTER to get started Username admin Password WAPC 1232HP show ip interface brief Method Figure 5 1 IP Information Screen W Configuring IP Address
8. shows how to start up the Web Management of the AP Controller Note the AP Controller is configured through an Ethernet connection Please make sure the manager PC must be set on the same IP subnet address For example the default IP address of the AP Controller is 192 168 1 100 then the manager PC should be set at 192 168 1 x where x is a number between 1 and 254 except 100 and the default subnet mask is 255 255 255 0 PC Workstation with Web Browser 192 168 1 x AP Controller gs RJ45 UTP Cable IP Address 192 168 1 100 Figure 6 1 IP Management Diagram Logging to the AP Controller 1 Use Internet Explorer 8 0 or above Web browser and enter IP address 192 168 1 1 the factory default IP address or the one that you have just changed in console to access the Web interface 2 When the following dialog box appears please enter the default user name and password admin or the password you have changed via console The login screen in Figure 6 2 appears Default Username admin Default Password admin ERIS con mH The server 192 168 1 100 is asking for your user name and password The server reports that it is from Loging Warning Your user name and password will be sent using basic authentication on a connection that isn t secure admin m E Y Remember my credentials Figure 6 2 Login Screen 3 After entering the password the main screen appears