1.                 Step 12    or  il    Step 13  Connect AC circuit breaker to grid     30    Electrical Connection    4 7 Grounding the Inverter    A WARNING     Because of the transformless design of the inverter  DC positive pole and DC  negative pole are not permitted to be grounded  Otherwise the inverter can stop  running     A WARNING     All non current carrying exposed metal parts of equipment and other enclosure  in the PV power system should be grounded  e g   PV arrays  DC circuit breaker  and inverter      A WARNING     For AC side  it is better to use a continuous irreversibly appropriately sized  conductor bare to ground inverter     Inverter          AC grounding I  electrode    Fig 4 3 AC Side of Inverter Grounding    31    JSIOKTL 12KTL 15KTL User Manual    4 8 Connecting RS485 Cable    4 8 1 Installing Monitoring System    The inverter provides RS485 interface to communicate with remote PC or logger  User  can monitor the state of the inverter  observe current running information and history  record via this interface     There are three methods provided for user to install the monitoring system     e Data logger    Inverter       Data logger    Fig 4 4 Collecting Data with SunInfo Data Logger    e Data logger  PC    Inverter       Data logger    Fig 4 5 Collecting Data with SunInfo Data Logger and PC    e PC    Inverter       Fig 4 6 Collecting Data with PC and RS485 RS232 Converter    NOTE    Suninfo M logger and RS232 RS485 converter are optional parts and 
2.            Q  Sys param  Run param  Pro param       Com param          Long press      Long press      Long press      Long press            P24 50 2009 11 18     18 35       E day 125 6kWh       P ac 15 000kW     Q       V de 300 4V   I dc 13 64       V grid 220 0V   I grid 18 24                F grid 50 0Hz                         Q Language  Time  Energy adj       Load default                      Standby time 010s                            Recover time 030s  Limit  p 100   Vgrid max 450V  Vgrid min 310V  Fgrid max 50 2Hz  Fgrid min 47 5Hz  Com param    Address  001                Long press  f    Language 0  bi  0  Spanish 1  Italy  2  Chinese 3  English  4  German 5  French  6  Japanese 7  Korea          Long press  f    Time  Date  09 11 18  Time 18 35 55          Long press      Energy adj   0000 kWh          Long press        Load default  Password  0000          Long press            Please wait           Fig 7 1 Menu Tree English  46    7 2 Default Menu    Menu Operation    When inverter is energized  LCD screen will display the default menu             GED 15 000Kw 000kW   125  SS 125 coxwn  mam 497600 kWh  EN EN run n             2009 11 18 18 35    1  In the default menu  LCD screen  displays basic information     There are also current date and time  See    7 9 2 Set Time    to adjust the current time    7 3 Adjust Contrast             ua     000kW   125  E 125 coxwn  SS 497600 kWh  EN CEN ro n    2009 11 18 18 35                     47          1  Long press b
3.  AA AAA AA Hy My hs T ty  Ts ke a ja A a a a  os o o TT T T a T S  a LTT  Tk kik ch hoki  A T   Ss sata a aa T A hy hh mh A A    hg a ih MM a ka fa a tu ka fa tu fi  Sa aly kie Sank  kie ati di Jai Das    SAS KANA  AO     Is A KA  KANA  NSS NSS NSS KAN    2    Fig 3 5 Dimensions of Holes    Hole size mm     S   O  e   G       gt  md  Y  G  G  a   A  0      O   ar         oO  z  vii   gt  md  O  0   a   AQ    Diameter B     Depth A        In order to avoid electrical shock or other injury  inspect existing electronic or    plumbing installations before drilling holes     16    Installation    Step 5  Insert the expansion bolts through the holes on the backplate and into the  holes you have drilled     Step 6  Fasten the backplate against the wall via washer  sping washer and  hexagonal nut               QT EA      T E  bp      T aa  bp  ms  A B C D E F    Fig 3 6 Demo Diagram of Backplate Fastening Process    Wall  Backplate  Expansion bolts    Washer    Spring washer    Hexagonal nut       CAUTION     Risk of damage to expansion bolt due to over tightening the nut     17    JSITOKTL 12KTL 15KTL User Manual    Step 7  Now you can hang the inverter onto the backplate as Fig 3 7 shows  Make    sure the two recesses on the back of the inverter fit perfectly together with the  backplate        FIQ 3   INSTAIMINQ tne inverter    18       Electrical Connection  GT    About this Chapter    This chapter proposes step bv step procedures to perform electrical connection and  related saf
4.  above requirements  Place    the backplate onto the chosen wall and adjust it until it is in a horizontal position     Step 2    Mark the positions to drill holes using the backplate as the template     Step 3    Drill seven holes at the marks you have made  The size of the hole is    illustrated in the below picture     Step 4    z  O  B          Q  YN  U  A    Item    ae Bay Maa Ta TN    Baa Ta  Ta T   a  TN  Ta  TN  Bh  Mig Ta  T  da Na Mh iy  he     NT  di  CNC E a T Ta a a Ma  yy Mh Ha  My     RC    AAA RRA  a Mh ig Ma Mh hy a a  ka e a A  ST A RAZA A a  A  ti b  i a a b a  cick kick OO A     A KO AS A i   hy bis  ka e    AAA    Fk Mg hg Mh Mg hh Bh tafu fu fa u 1  RARAS HM HH ION  ty  a Th     a hg Ma ha a Hy My  Hy Me  Hh hy  Hy Sa Hh     a A Skt Sook   e    Ca       The diameter of hole    The depth of hole       ki    ee  EE hat  HA  ha  g   gi  oon     ha  g   gi  oon  vee  g  al  oon  ee  F    sia  jigi  wa    w k k   W ta ko a kal ko ta it ko  SEERA  a hh a a y hy  y y ha  a Mh hhh  HS  A AAA AAA Ta ha  AAA AAA  RA AA AAA AAA AA  hock hh eek ACA hk ok a A aa a ha  Mag Mh Mh Sg y Ma aq My  Sy ha Sh  Sa Ma hy ay a Th Ta  Pa a a S a a a a  tM T AAA a T T T a T a  hh a a ah T  kk kk e e da  Mag Mh Sy y Ma  ig May Shy Thy Ma hy Sa Sa Sa SS a   ee ah Shh OD a ak heh l    A A a a Sk  Pate ih A A eh A A  A ja a   A A AA AN a    l  la  T kl hy  kl a  f   st hh BC ACA AA AAA SALAINN   SSC ES aS Sa AS  JA JA a a A a Maa AA A ACA KE ka ko A AAA  ic pc a a chy A a O ANN  A AA
5.  into corresponding RS485 terminal of  Inverter 1     Step 3  The two lines of the other end of RS485 cable  labled A and B  connected to  corresponding lines of RS485 bus  as the above diagram     Step 4  Connect other inverters to RS485 bus in the same wav     Step 5  Connect the end of RS485 bus to A1 port and B1 port of Suninfo     logger     34    Electrical Connection    e Data logger  PC    Inverter 1 Inverter 2 Inverter n n lt 30     mm Suninfo   Logger                                              RS485 Bus L  mm       Wiring procedure   Step 1  A resistance with 1200 is connected at the initating terminal of RS485 bus     Step 2  Plug the connector of RS485 cable into corresponding RS485 terminal of  Inverter 1     Step 3  The two lines of the other end of RS485 cable  labled A and B  connected to  corresponding lines of RS485 bus  as the above diagram     Step 4  Connect other inverters to RS485 bus in the same way   Step 5  Connect the end of RS485 bus to A1 port and B1 port of Suninfo     logger   Step 6  Connect RS232 port of SunInfo    logger to RS232 port of PC     e PC    Inverter 1 Inverter2 Inverter n n lt 30      ease                            AIRE IA At Sel    RS485 Bus Ke RS232 Bus    Wiring procedure   Step 1  A resistance with 1200 is connected at the initating terminal of RS485 bus     Step 2  Plug the connector of RS485 cable into corresponding RS485 terminal of  Inverter 1     35    JSITVOKTL 12KTL 15KTL User Manual    Step 3  The two lines of the o
6.  is within DC input  voltage range of the inverter  Voltage over 1000V can damage to the inverter     AN WARNING     Risk of damage to the inverter     Make sure that the maximum short current of each string is less than maximum  input current  Please refer to chapter    9 Technical Specification        CAUTION     For each input zone  PV arrays should respectively have a homogenous  structure  including the same type  the same number  identical tilt and identical  orientation     24    Electrical Connection  4 5 2 Assembling DC Cable to Connector    All DC cables are equiped with water proof direct plug in connectors  which mate with  DC conectors at input zones     DC positive assembling procedure     Step 1  Unscrew the water proof terminal in the following direction           Step 2  Insert appropriately sized DC cable through water proof terminal     Step 3  Strip off insulation layer of DC cable  The length of strip insulation is  approximate 8mm        Step 4  Crimp cable core with hand crimping plier        v    q          Step 5  Plug cable gland into connector housing until there is    Ka    voice       vi     jam     lt a             Step 6  Tighten the water proof terminal in opposite direction           DC negative assembling procedure     Step 1  Unscrew the water proof terminal in the following direction     25    JSIVOKTL 12KTL 15KTL User Manual          Step 2  Insert appropriately sized DC cable through water proof terminal     Step 3  Strip off insulation l
7.  kinx Ce  Current C AA     Met Wei ght  C y       arenero    A ual L    ee Bi Cri       Fig 3 1 Nameplate of Inverter       Fig 3 2 Moving the Inverter    3 5 The Requirements of Installation Site    11    Installation    The inverter is about 50kg  Proper device is needed or with the help of other people to  avoid damage to the inverter when installing or moving     This section provides guidelines to help you choose the best installation site   suggestions to make sure the unit optimal operation  the warnings to avoid damage to  the unit or the operator     JSIVOKTL 12KTL 15KTL User Manual     N WARNINGI    When choosing the installation site  Ensure that there is no electromagnetic  interference with other electrical and electronic equipments     Requirements     The wall selected should be strong enough to hold the weight of the inverter     lt is suggested that the inverter be installed vertically        The inverter unit with  P65 can be installed outdoors     Do not install the unit in the direct sunlight or in an enclosure exposed to the direct sunlight   Exposure to the sun may cause additional internal heating  This can result in reducing output  power     The chosen installation site maintains ambient temperature range from  25     to 60      When the  temperature exceeds 45      the output power will reduce     The humidity of chosen installation site never exceeds 95  Moisture may result in corrosion to  the lid and damage to the inner electronic components     1
8.  the main control menu in the    default menu     2  Short press button  0 to move  arrow to    Start Stop        3  And then long press button O   to enter into its submenu     4  Short press button  9  to move  arrow to    Stop        5  And then long press button O     to enter into its submenu     6  Long press button   O  gt  to  confirm    Start    command     JSIHOKTL 12KTL 15KTL User Manual    7 6 Monitor Running Information            15 000kW    END 125 cocwn  497600 kWh    2009 11 18 18 35         14 2                 Run inform       His inform  Start Stop  Set param   E da 125 6kWh   Temp 49 5    P in 9928W P out 9960W          U PV1 380 0V U PV2    380 0V                      CO  reduce 29760kg    l PV1 20 3A LPV2 20 3A  P PV1 77148   P PV2 7714W  R S T  220 0V 220 0  68 0A 68 0A 68 0A  42W 42W 42W  50 6Hz 50 1Hz 49 9Hz  E total 497600kWh       E month 3750kWh  H tot 20 3A       Min da 486min         Power Curve  100 09 11 18          50    1  Long press button O  to  enter into the main control menu    in the default menu     2  Short press button  Q  to  move arrow to    Run inform        3  And then long press button    O  to enter into the submenu     4  Short Press button   O  or  O  to turn pages     7   Monitor Running Record       15 000kW  EN 125 60kWh    497600 kWh    14 2       2009 11 18 18 35          Run inform      His inform  Start Stop  Set param            gt  Run record    Fault record          P 1 2 Run record T 2         2009 11 17  50   200
9. 0 60Hz    Grid Frequency   47 5 51 5Hz  47 5951 5Hz  47 5951 5Hz   Range 57 61 5Hz 57 61 5Hz 57 61 5Hz    Output Current    lt 3   at nominal power     lt 3   at nominal power     lt 3   at nominal power   THD    DC Current  lt 0 5  at rated output  lt 0 5  at rated output  lt 0 5  at rated output  Injection current  current  current     0 9 lagging  0 9 leading    0 9 lagging  0 9 leading    0 9 lagging  0 9 leading     System    Max  Efficiency   98 0  98 0  98 0   Euro  Efficiency   97 2  97 2  97 3     70    Technical Specification    Protection  Degree    Operating  25C  60  C  25 C  60 C  25 C  60  C  Temperature    Relative 0 95   0 95   non condensing   0 95   non condensing  Humidity non condensing    Cooling method   Controlled forced air Controlled forced air Controlled forced air  cooling cooling cooling    Max  Altitude 2000m 2000m 2000m    Displav and Communication    Communication   RS485 RS485 RS485  Interface    Mechanical Data    Dimensions 648 695 232 648 695 232 648 695 232   W H D      Net weight 45kg 51kg 55kg       71    JSIVOKTL 12KTL 15KTL User Manual    72    JSITOKTL 12KTL 15KTL User Manual       Appendix         About this Chapter    This chapter proposes contents related to exclusion of liability and contact     73    JSIHOKTL 12KTL 15KTL User Manual    10 1 Exclusion of Liability    The contents of this manual will be periodically checked and revised if necessary   However discrepancies cannot be excluded  Please download the latest version of  t
10. 2    Installation    Do not install the inverter unit on flammable construction materials or on the building that contains  flammable materials     Take enough space for heat dissipation into consideration when choosing the site  The following  suggestive value for the space to keep clear around the inverter should be adopted     Min  clearance suggested       Install the inverter at eye level  Meanwhile some space at the bottom needs to be kept for  electrical connection     Do not install the inverter in this site where the children can reach  The housing of the inverter will  be very hot  It is risk of burning     Do not install the inverter in living area  Noise can be produced during running of the inverter   which will affect your daily life     13    JSIVOKTL 12KTL 15KTL User Manual    3 6 Dimensions of Inverter          Fig 3 3 Outline Dimensions of Inverter    Table 3 1 Dimension Value          14    Installation    3 7 Installation Procedure    There is a backplate and fasteners supplied to install the inverter  If you don t want to  use the supplied backplate  you can drill holes refer to its dimension below     33    394 9    3        Fig 3 4 Dimensions of Backplate    In the following pages we will introduce the installation procedures using the provided  backplate and fasteners     15    JSIOKTL 12KTL 15KTL User Manual    INSTALLATION PROCEDURE    Step 1  Get the supplied backplate and fasteners from the package     Choose the best installation site according to
11. 9 11 16  32                   P24 50 2009 11 18  125 6kWh  P ac 15 000kW    300 4V    18 35                  V grid 220 0V  F grid 50 0Hz    l grid 18 2A                2009 11 18  E total 497600kW  49 5  C    18 35                   91    Menu Operation    1  Long press button O  to  enter into the main control menu    in the default menu     2  Short press button    B to  move arrow to  His inform      3  And then long press button    O  to enter into its submenu     4  Short press button TE to  move arrow to    Run record        5  And then long press button    O  to enter into its submenu     6  Short press button O  to  move arrow to time you want to    verify     7  And then long press button    v   to enter into its submenu     8  Short Press button   O  or  O  to turn pages     JSIHOKTL 12KTL 15KTL User Manual    7 8 Monitor Fault Record       15 000kW  EN 125 60kWh    497600 kWh    2009 11 18 18 35    14 2             Run inform      His inform  Start Stop  Set param          Run record      gt  Fault record    P 1 1 Fault rec T 2    1 gt  2009 11 05 09 15 59  Samp flt 0001   2 gt  2009 11 05 09 15 59  Vac high 451V    Table 7 1 Fault description       1  Long press button O  to enter  into the main control menu in the    default menu     2  Short press button    W     to move  arrow to    His inform        3  And then long press button     to  enter into the submenu     4  Short press button  0  gt  to  move arrow to    Fault record        5  And then long press but
12. JALP   Q WER    About This Manual    Contents of this Manual  This manual is applied to grid connected inverters of JSI 10KTL  JSI 12KTL  and JSI 15KTL     This manual provides detailed product introduction  installation guide  operation guide  and maintenance guide     This document also provides very important safety instructions about installation   operation or maintenance     Target Reader    The manual is provided to installation technicians and users     The tasks of installation and troubleshooting in this manual must only be performed by  the qualified personnel     The tasks of menu operation and routine maintenance can be performed by the users     Retention of this Manual    This document must be stored near installation site and must be available at all times     symbols Used    Important instructions contained in this manual should be followed during installation  and maintenance of the inverter  And they will be highlighted by these symbols     JSI 10KTL 12KTL 15KTL User Manual     N DANGERI    This svmbol indicates a dangerous situation which  if not avoided  will cause  death or severe injury     A WARNING     This symbol indicates a dangerous situation which  if not avoided  could result  in death or severe injury     CAUTION     This symbol indicates a dangerous situation which  if not avoided  could cause  minor or moderate injury     NOTE    This symbol indicates a situation which can help the equipment optimal operation     Symbols on the body of the inv
13. Run inform  His inform  Start Stop    gt  Set param       Set param    Password  1111        Sys param  Run param  Pro param   Com param    Language  Time         Energy adj  Load default          56          1  Long press button O  to enter  into the main control menu in the    default menu     2  Short press button Q  to move  arrow to  Set param      3  And then long press button O   to enter into the submenu     4  Short Press button O  or O   to input correct password     5  Short press button O  to move  arrow to    Sys param        6  And then long press button O   to enter into its submenu     7  Short press button  9  to move  arrow to    Energy adj       8  And then long press button O   to enter into the submenu     Menu Operation    9  Short Press button TAE or 0  to set value    Energy adj    0000 kWh 10  And then long press button     9  to confirm           NOTE    The positive symbol         can also be changed to negative symbol           It is needed to perform the    Energy adj    command in case that the total power  displayed in LCD  E total  has difference with reading value from the external power  measuring device  like an electrical meter      The adjustable range is from  9999  9999 kWh      Power adj value    Real measured value   E total reading value      7 9 4 Load Default    CAUTION     If you perform the command    Load default     all running information and history  information will unrecoverable cleared          1  Long press button O  to en
14. TION     If you want to restart the inverter  rotate DC switch to    ON    position again     42       Commissioning         About this Chapter    This chapter demonstrates how to check before commissioning and operation  procedures     43    JSITOKTL 12KTL 15KTL User Manual    Verify before commissioning    Verify whether inverter is fastened onto the wall  See    1        2 Check whether all cables are undamaged  properly   See     4 4 Specification of  insulated and adequately dimensioned  Cables      3    Check whether all cables are firmly attached and See    4 5 Connecting inverter  correctly  to PV Arrays    to    4 8  Connecting RS485 Cable          Commissioning Procedure   Step 1  Make sure all items above meet demands   Step 2  Switch off external AC circuit breaker     Step 3  Rotate DC switch to    ON    position     NOTE    After external circuit breaker is closed in the PV power system     e PV arrays initialize and supply DC power to inverter   e When DC voltage exceeds 250V  DC Bus starts to charge   e Inverter verify whether grid conditions are OK     e If the conditions are OK  inverter feeds AC power to grid and enters into the  running state     Step 4  Observe state of LED indicators and LCD screen     CAUTION     If inverter   s commissioning fails     FAULT    indicator will be lit  And    EE  gt  in  the LCD screen will display type of malfunction     In this case malfunction must be removed and then repeat step1 to step 4     NOTE    If inverter s co
15. ayer of DC cable  The length of strip insulation is  approximate 8mm        Step 4  Crimp cable core with hand crimping plier               q    Step 5  Plug cable gland into connector housing until there is    pa    voice        CT    NA        lt a    Step 6  Tighten the water proof terminal in opposite direction           The positve and negative connectors are marked with polority symbols and colored  cable  Red cable represents DC positive conector and blue one represents negative     If positive and negative cable have been assembled  it is easy to plug these  connectors to the corresponding connectors at the bottom of inverter     When connectting connectors  they will be correctly locked in the mating place     NOTE    Release the locking part by pressing on the ribbling of the locking hooks and pull them  outwords     26    Electrical Connection                     4 5 3 Wiring Procedure    There are DC1 input zone and DC2 input zone  each with its own MPP tracker  as  Fig 4 2 shows     Wiring Procedure     Step 1  Assemble DC cable to connector at the inverter side  See    4 5 2 Assembling  DC Cable to Connector        Step 2  Manually rotate DC switch at the bottom of the inverter to    OFF    position     Step 3  Check connection cable of one PV array string for correct polarity and that the  maximum input voltage does not exceed 1000V     Step 4  Plug DC positive and negative connector into corresponding terminasl     If there is a    pa    sound  it means DC con
16. can be orded  from Jalpower     32    Electrical Connection    4 8 2 Assembling RS485 Cable to Connector    All RS485 cables are equiped with water proof direct plug in connectors  which can  mate with RS485 conectors at the bottom of inverter     Assembling procedure   Step 1  Dismantle RS485 connector in the same way of DC connector     Step 2  Connect appropriately sized cables to pini and pin3  as shown in the  following picture      lt a             NOTE    Pins are marked with symbols at the other side     Step 3  Tighten its water proof terminal     33    JSIHOKTL 12KTL 15KTL User Manual    4 8 3 Connecting RS485 Cable    RS485 is communication standard for bidirectional transmission of data between one  or more inverters and a PC or a data logger   If there is more than one inverter to communicate with a PC or a data logger  it is    crucial to configure communication parameters of each inverter  See    7 9 7 Set  Communication Parameter        CAUTION     RS485 bus    requirements to ensure quality of communication   e RS485 bus should be shielding twist pair    e Shielding layer of RS485 bus should be single point grounding  grid  indicating shielding layer in following pictures    e Data logger    Inverter 1 Inverter 2 Inverter n n lt 30             me            Suninfo     Logger     A                   RS485 Bus d    Wiring procedure   Step 1  A resistance with 1200 is connected at the initating terminal of RS485 bus     Step 2  Plug the connector of RS485 cable
17. cification Of Cables       oocccccccccccccccocononnncncnnnnnononononnnannnnnnnnnnnnononnnnnnnnnnnnnnnnnnnnnnnnnnnnnrnnnnnnnnnnnrnnnnnnos 23  4 5 Connecting inverter to PV ArrayS eeraa sana aapa a aa a aa aaiae 24   I EE EE AN 24   4 5 2 Assembling DC Cable to Connector             ccccccceccecceaeeeseeeeeceeeeeecesaaaeseeseceeeeeeeeesssuaaaaaeseeeeeeeeess 25   4 5 9 Minino  POG CONC serere A araea ariaa 27  4 6 Gonnecung Inverter t0 AG GNO ii a ici 28  47 Grounding MS IVC o aa 31    JSIVOKTL 12KTL 15KTL User Manual    AS  SOME RS4SS Dead 32  AS 1 MStalind  Moore  L  i T   l ikrah 32  4 8 2 Assembling RS485 Cable to Connector    occcccnncccccccccoconnccncnononnnonononnnnncononnnnnnnnnnnnnnannnnnennnnnnnnss 33  A 6 9 GONNECIING  Rs485 Gable ni idea 34   5 LCD Panel and DOS Within B   AN o UE SO A 38   OZ LENIN AO bee ani ici iodo ido tia ta lol pois 38   PP P      E o 38   A A e E SEUS PO a 39   DS CD SiO MOQLI E tn 40   BOG WIC Mercier co 41    6 COMMISSIONE nO    Menu Op erat OI  ciscctecastsesaticecsisacticectsvasisia atado    Til Overviewot Mensen a a ja 46  FORA Dein MeN sissa r a A 47  TS AOIUSE COMMAS AN 47  To ENVE ie O 48  FOODIE ET art te f A E E A ee ee ee N  49  7 6 Monit  r RUNING INTOFMAON sss eee A ees 50  77 Monitor Running Record e a A A C   ghas easa tea     51  O MONIO FAURE coast cuado nd rodados dd 52  7 9 Parameters Setting        ccccccccccccccoooccnnanccnnnnnnnononononnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnnnnrnnnnnnenennnns 54  AE A ae S
18. e is a fault which is not removed yet     2  Perform troubleshooting in according to fault type in LCD  screen  See    8 1 2 Troubleshooting of faults in LCD Screen        3  If it can be solved  please contact Jalpower  See 10 2 Contact  Us           8 1 2 Troubleshooting of faults in LCD Screen    Type of fault Troubleshooting    Vdc high 1  Disconnect AC circuit breaker     2  Rotate DC Switch to    OFF    position   3  Check the voltage of DC side     4  Restart the inverter until the DC voltage return to allowable  range     Vac low 1  Disconnect AC circuit breaker     2  Rotate DC Switch to    OFF      3  Check the voltage of grid side        64    Troubleshooting and Maintenance    Type of fault Troubleshooting    Vac high  F fault    IPM flt    4  If local grid condition exceeds AC demands of inverter  Reset  the protecting parameters  See    7 9 6 Set Protecting  Parameter       And if local grid voltage exceeds the upper limit value of     Vgrid max     or if local grid voltage is under the lower limit value    of  Vgrid min   please contact your local electricity company to  adjust the grid voltage     5  If the fault can not be solved  please contact Jalpower  See     10 2 Contact Us        1  Disconnect AC circuit breaker    2  Rotate DC Switch to    OFF       3  Check the frequency of grid side    4  If local grid condition exceeds AC demands of inverter  Reset    the protecting parameters  See 7 9 6 Set Protecting Parameter       And if local grid frequency exc
19. e than two seconds Return to parent menu     Press less than two seconds Move to next row  or move to previous page  or  increase setting value     Press more than two seconds Select menu item or confirm setting        NOTE    When the two buttons l and    0  are pressed more than three seconds  inverter  will stop running and enter into the  Kev stop  state     NOTE    The background illumination of LCD screen will go out to save power if there is not  button operation in two minutes  You can activate again by pressing any button     5 4 LCD Screen    LCD screen can display the current state of inverter  current running information   history information and setting parameters menu  They can be accomplished with  button operation  see    7 Menu Operation        LCD screen and buttons provide a good human computer interaction interface     39    JSIOKTL 12KTL 15KTL User Manual    In its default interface  user can observe operation mode or fault type of inverter        15 000kW    END 125 coxwn  497600 kWh    2009 11 18 18 35         2          Fig 5 2 Default Interface    NOTE    If there is no button operation in three minutes  it will go back to default menu     5 5 Operation mode    This chapter illustrates the operation modes of inverter     Stop  The inverter is shut down   Stand by    Stand by mode is entered for insufficient input power  Ppv 0 for 3 minutes   Ir  stand by mode the inverter will wait until the DC voltage recovers to 220V in  standby time  set by user  s
20. ee 7 9 5 Set Running Parameter        Startup   The inverter is initializing and synchronizing with the grid    Run    After being energized  the inverter tracks the PV arrays  maximum power point   MPP  and converts the DC power to AC power  This mode is the normal    operational mode   Fault    lf a fault occurs during running  the inverter will automatically stop operation   disconnect the AC relay and display the fault type in the LCD panel with the       Fault    LED lit   Once the fault is removed inrecoverv time  set bv user  see 7 9 5 Set Running  Parameter    the inverter will automaticallv resume running     Kev Stop    The inverter will stop operation bv manual stop through LCD menu  this condition  needs manual restart through LCD menu     40    LCD Panel and DC Switch       Fault is cleared A fault occurs        T Recover time  30 300s       T Standby time       Perform command  e    Stop     gt     Perform command  ce    Stop     gt        Inverter is energized After running normally    Fig 5 3 Mode Transition Explanation Diagram    NOTE    If    2  and    9  button are long pressed  inverter will enter into the  Kev stop  mode     5 6 DC Switch    DC switch is designed for stopping the inverter     Inverter work automatically if input and output meet the requirements  If you want to    interrupt its running or if a malfunction occurs  it can be rotated to    OFF    state  And  then the inverter will stop running     41    JSITOKTL 12KTL 15KTL User Manual    CAU
21. ee Ore 54  LID SOM B  A 55  7 9 3 Setting Total Generated Power Adjustment           sse eennnnnnznnnnnnznnrenzzntenzzzzzrrzzamanzzznzztzzzznni 56  E a A A 57  7 975 Set RUNNIN Pardimietet tabs isib dal tata bidet   u na bba tala dust Se sostenn dieti dd 58  F  s as ii PIOlSClING P  ar   lel l i g a g  an 59  197 Set Qommunication Para mietet a 61    8 Troubleshooting and Maintenance             ssssseessnnezzzonenneseznsennesennesnnnsennoennnoennes 03    S L IrOUDIESMOOULI PU xiri A 64  8 1 1 Troubleshooting of LED Indicator            nanna nara rna naAAn An En nrnnEnAnn EEA EEA A 64  8 1 2 Troubleshooting of faults in LCD Screen    nnnnnnnnnnnnnnnnn nn nn ran r nr rna n nanna nanna nn n a 64   e IIIT Fl el IA    S E E E EE A A E E EE E E E EE A E 66  AA Ar EE T AE EE E ET E EE E EEE E E E E E 66  O22 ZC DIAC Fa is vi i N O ada idee 67    8 2 3 Clean Air Inlet and Outlet l i ikona ida l 67    9 Technical Specificatioti ams tario 69  IO Appendix ii E opener ane ne Sennen ry meen meaner 73  101 Exelusiont OF BEI  is sisa un ha 74  102 OOA rU   ii e A e a A 75       Safety Instructions  m       About this Chapter    This chapter describes very important safety instructions  Please read    Safety  Instructions    carefully before anv work with the inverter     JSIOKTL 12KTL 15KTL User Manual    The inverter is designed and tested according to international safety requirements   But as all electrical and electronic equipments  certain precautions should be  observed during insta
22. eeds the upper limit value of     Fgrid max     or if local grid frequency is under the lower limit  value of  Vgrid min   please contact your local electricity  company to adjust the grid frequency     5  Close AC circuit breaker    6  If the fault can not be solved  please contact Jalpower  See     10 2 Contact Us       If this malfunction occurs  the reasons are very complicated     1  Disconnect AC circuit breaker     2  Rotate DC Switch to    OFF    position   3  Check the temperature of radiator  If its temperature exceeds  80 C  gt  Restart the inverter until it recovers to environment    temperature    4  Recover DC switch to    ON    position    5  Close AC circuit breakeres    7  If this malfunction happens again  please contact Jalpower   See    10 2 Contact Us       1  Check whether AC circuit breaker is off    2  Check whether AC cables are all firmly connected    3  Check whether grid is cut off     4  If all conditions are OK and this malfunction still occurs in the  LCD screen  please contact Jalpower  See    10 2 Contact Us           65    JSITOKTL 12KTL 15KTL User Manual    Type of fault Troubleshooting    Tem flt 1  Check whether AC output power exceeds rated power too  much     2  Check whether fans work normally and whether there are  some abnormal from fans  Otherwise please replace broken fan     See    8 2 2 Replace Fan      3  Clean air grills of outlet  See    8 2 3 Clean Air Inlet and Outlet        Com flt 1  If this malfunction happens  wait for a 
23. erter     High Voltage      There exists lethal voltage  Please wait at least five minutes and then perform  any work with the inverter after disconnecting the electrical connection of the  inverter     Risk of Burning      The surface will be very hot during running  Avoid touching the housing of  equipment except LCD display panle and DC switch when it is working     Contents    About This Wat al iii iii ii eee LL    Coment ofthe Manali iet ke aa g a aa   a   a ta  t R g  ati  Ga 1  target A a a A 1  a SSI ea LCH Ta   mmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmmrmrickrmi iris 1  o A a a a 1    Safety Viste CHOIS sooner iien aan L    2 Product CV Givi ew ccosa e o DS    A CR USE A R 6  A E aa 7  2 3 Features of JSI 10K 12K  1 SKU LA III gi S s site gie i A A A 7  ies AD iz a 8     gt  imstande    2  1 Uripackineana Inspector ie e tA A 10  2 RACKING LIS aso saa tad 10  A at g   a i ra a ka eee rere rte 10  SEMONO INVERNO tisaie ia ada tab es a u du a   da a 11  3 5 The Requirements of Installation Site               cooonncnccccnnnnncncnnnococnncnnnnonancnnnononnnnnnnnnnnnnnnnnnnnnnonnnannnnnos 11  2G Dimensions Ol Ives a taa 14  Ox    Installation  POC      cmmmmimimimmimim iminrmmirmi      N 15    4 Electrical Connection            sessccssoseossooseossossesscoseossooscossosssossosscsseoseossosscossossosseossos LO    4  i  21g 1 1 rol Ree y  I   ht ena A aka 20  42 OVErview Of Electhical MStAllA OM  can Ki dales 21  2 SVT Ves 1  SS GTO WOM ocaso 22  4 4 Spe
24. ess button O  or O     Vgrid max 450V to set protecting parameters   Vgrid min 310V   Fgrid max 50 2Hz O   Fgrid min A7 5Hz 8  And then long press button    to confirm setting           NOTE     Vgrid max  and  Vgrid min  are upper limit value and lower limit value of grid voltage  respectively   Fgrid max  and  Fgrid min  are upper limit value and lower limit value of  grid frequency respectively     Once grid voltage or frequency exceed this rang  the inverter will stop running and    fault type is displayed in the LCD screen     Table 7 2 Range of Protecting Parameters    Data name   Simple explanation Adjustable Default value  range    maximum grid voltage 435V 455V 450V  minimum grid voltage 300V 315V 310V    60 2Hz 61 5Hz 60 2Hz for 60Hz system   Fgrid min minimum grid frequency 47  0Hz 49 5Hz 47 5Hz for 50Hz system   57 0Hz 59 5Hz 57 5Hz for 60Hz system     maximum grid frequency 50 2Hz 51 5Hz 50 2Hz for 50Hz system        60    7 9 7 Set Communication Parameter            15 000kW   EN 125 60kWh   ESB 197600 kwh  t Run          2009 11 18 18 35         Run inform  His inform  Start Stop      gt  Set param       Set param    Password  1111    Sys param  Run param  Pro param   gt     Com param    Com param    Address  001    NOTE    The range of communication address is 1 247           Menu Operation    1  Long press button O  to enter  into the main control menu in the    default menu     2  Short press button  0  gt  to  move arrow to  Set param      3  And then long 
25. etv instructions     19    JSIOKTL 12KTL 15KTL User Manual    4 1 General Safety    A WARNING     Improper operation during the wiring process can cause fatal injury to operator  or unrecoverable damage to the inverter     Only qualified personnel can perform the wiring work     A WARNING     All electrical installations must be in accordance with local and national  electrical codes     A WARNING     Only after receiving prior approval from the utility company and qualified  personnel installing the inverter  you can connect the inverter to the utility grid     A WARNING     All cables must be firmly attached  undamaged  properly insulated and  adequately dimensioned     CAUTION     These regulations should also be followed   e The regulations related to the electricity fed into the grid    e The safety instructions related to the PV arrays    20    Electrical Connection    4 2 Overview of Electrical Installation    Electrical connection of the inverter includes DC connection  AC connection and  communication connection         BR ed Emma a Ce                                                                                                                               Fig 4 1 Electrical Connection Diagram    Connection area of inverter It is located at the bottom of the inverter  AC circuit breaker User equips this device    ee       me      I       21       JSIVOKTL 12KTL 15KTL User Manual    RS485 RS232 converter User can order it from Jalpower       Remote PC User equips t
26. his device  Suninfo M logger User can order it from Jalpower    NOTE    The dashed line in the above diagram indicates that there is another way of  communication connection  See    4 8 Connecting RS485 Cable        4 3 Terminals Description    All electrical terminals are all located at the bottom of unit  Fig 4 2 shows the  connection area     NOTE    Enough space should be kept for electrical connection at the bottom of the inverter  when choosing the installation site        A E  E   E       Di   DM        O    DM   Mi       Fig 4 2 Terminals Description       22    Electrical Connection    4 4 Specification of Cables    DC cables and RS485 cables of PV power system are equipped with water proof  direct plug in connector  Vou ll find these connectors in the package     For electrical connection in PV power system  specification of all cables used should  meet following requirements     Table 4 1 Specification of cables    Recommended value       23    JSIOKTL 12KTL 15KTL User Manual    4 5 Connecting inverter to PV Arrays    4 5 1 Safety    As input of the inverter in the PV power system  PV Arrays  features should be paid  attention to  Please refer to PV module s data sheet     When designing PV arrays  following requirements should be met      N DANGERI    Lethal voltage existsl    Do cover the PV arravs  Exposed to sunlight  PV arravs will output lethal  voltage     A WARNING     Risk of damage to the inverter     Make sure that the maximum open voltage of each string
27. his manual via website www Jalpower com However discrepancies cannot be  excluded  No guarantee is made for the completeness of these documents  Please  contact our company or distributors to get the latest version     Guarantee or liability claims for damages of any kind are excluded if they are caused  by one or more of the following     Improper or inappropriate use of the product  Operating the product in an unintended environment    Operating the product when ignoring relevant safety regulations in the  deployment location    Ignoring safety warnings and instructions contained in all documents relevant to  the product    Operating the product under incorrect safety or protection conditions  Altering the product or supplied software without authority    The product malfunctions due to operating attached or neighboring devices  beyond allowed limit values    In case of unforeseen calamity or force majeure    74    JSITOKTL 12KTL 15KTL User Manual  Appendix    10 2 Contact Us    If you have any questions about this product  our hotline will be happy to assist you   Please keep the following data when contacting Jalpower     JALPOIWER    Address     Jalpower Corporation Ltd      USA  107 East Meda Ave  Glendora  2491741 LIGA  Tel   1 626 9h 35 2054  Emall salesifjalponvet com    Taiwan  2E  No 4  Aly 1  Lo  225  Sec  1  Meibu Rd  Meihu Dist  Taipei City 114  Taiwan    ROC   Tel   886 2 265937 37    Emall supporti  ijalpower  com  China    Room 2504  No 18   Shun Yi Road  Sha
28. instructions are also  included     JSI 10KTL 12KTL 15KTL User    3 1 Unpacking and Inspection    The unit is thoroughly tested and inspected strictly before delivery  Although sturdy  package is adopted  damage may still happen during the shipping     The first thing you should do is to check the packing box when receiving the inverter  unit  Meanwhile please check the completeness of the delivery contents     If damage to the packing box is visible  or if you find that the inverter unit is damaged  after unpacking  please notify the shipping company and Jalpower Company  If a  related photo is supplied  you will get faster and better service     3 2 Packing List    e Inverter unit   e Backplate   e Fastener M10 85    e DC positive connectors 7    DC negative connector 7  e RS485 connector User   e manual Qualification   e certificate Warranty   e card   e Product test report   e Packing list    e Delivery inspection report    3 3 Nameplate    Nameplate is shown on the package box and on the side of the inverter body  You can  check whether the serial number and the type of inverter is right  as well as other  parameters information     10    3 4 Moving Inverter    A WARNING     Risk of injury due to ignoring the weight of the inverter     GADESARECTEOINTERYERTER                   Type C TL    Serial Hal   aom    Cite of Marufature  IMA    AC Power  Te   AC Wokbago    ary J  AC Frequency o Bh     AT Cimet    315    MPP DC Voltage Rares   Arm   Max  DIC Wo ba ge i LC 1D00r   
29. l features of JSI10K 12K 15KTL        e Power reduction 100  60  30  0   meets German EEG requirements      Reactive power control with power factor from 0 9 lagging to 0 9 leading    e Max efficiency at 98     e Wide DC input voltage range with max  1000V    JSITOKTL 12KTL 15KTL User Manual      Double MPP trackers for different installation inclinations    e  Weather proof design IP65  for harshest working enviornment  e High reliability with full protective functions   e Compact design with high quality aluminium housing    e Water proof direct plug in termimals   e TUV certification  KEMA DK5940    2 4 Product Description    A    Po 4   s  i j Wi     6 A Mili  MU       Fig 2 3 Product Description    1 Displav panel Running data and configuration parameters are displaved in the LCD  screen  Detailed information will be introduced in following     Air outlet Hot air generated during running process is exhausted via the air outlet     The handles are designed for transport and install the unit   Entrance of cool air     5 DC switch In normal condition it is in    ON    state  It can be turned off manually in  any emergency condition  And then the inverter will stop running     Connection They are DC input terminals  AC output terminal and RS485  terminals communication terminal           Installation         About this Chapter    This chapter proposes how to choose installation site and gives step by step  procedures to install the inverter onto the wall  And related safety 
30. lling  operating and maintaining     Incorrect operation or work performed incorrectly can result in damage to     e The life and well being of the operator or the third party  e The inverter and other properties that belong to the operator or the third party    Therefore in order to reduce risk of injury and ensure the safety of the inverter  you  must carefully read and follow all instructions  cautions and warnings      N DANGERI    First disconnect the inverter from utility grid     AN DANGER     e Even when the inverter is disconnected  lethal voltages still exists within  the inverter     e Before any maintenance work  you should wait for at least five minutes and  then perform work     A WARNING     All tasks of installation and maintenance must only be performed by qualified  personnel     e They are trained specially     e They have read this manual  and comprehend all operation methods and  related safety instructions      N WARNINGI    All electrical installations must be in accordance with local and national  electrical codes     safety Instructions    A WARNING     Only after receiving prior approval from the utility company and qualified  personnel installing the inverter  you can connect the inverter to the utility grid     A WARNING     All cables must be firmly attached  undamaged  properly insulated and  adequately dimensioned     A WARNING     When choosing the installation site  this ingredient to ensure that there is no  electromagnetic interference with 
31. mmissioning succeeds     RUN    indicator will be lit     If inverter s commissioning succeeds  EB  in the LCD screen will display    RUN        44    Menu Operation  a    About this Chapter    This chapter shows all menu operations  User can know how to check the state of the  inverter  Current running information and history information  And how to set the  parameters of the inverter is also included     45    JSHOKTL 12KTL 15KTL User Manual    7 1 Overview of Menu       TUTTE CENTET    Contrast adj  50        Long press  Y         Long press    Long press  f          ki    15 000kW    ec cow  497600 kWh            Long press  E              2009 11 18 18 35    Q  Run infor       His inform  Start Stop  Set param             Long press  f    Long press  f        E dav 15 6kWh       Temp 49 50           P in 9928W   P out 9960W          U PV1 3  0 0V_  U PV2 380 0V          l PV1 20 3A l PV2_    20 3A          P PV1 7714W _ P PV2 7714w                      DERZ TUTA                ee             Min day 486min                   14 0             Long press  f       Q    Run record       P 1 2 Run record T 2       gt  2009 11 17  50   2009 11 16  32                 Fault record      Long press  f    PA Fault rec T 2    1 gt  2009 11 05 09 15 59  Samp flt 0001   2 gt  2009 11 05 09 15 59  Vac high 451V          Long press         Stop       Q     Start J    Start Confirm                  Long press    Stop Confirm           Set param    Password  0000          Long press       
32. nector has attached to terminals         Step 4  Connect other strings in the same procedure     27    JSHOKTL 12KTL 15KTL User Manual    4 6 Connecting Inverter to AC Grid    A WARNING     Only after receiving prior approval from the utility company you can connect  the inverter to local utility grid     A WARNING     The grid should meet these following requirements  Otherwise the inverter will    not work   e Grid Voltage 3  310V 3 450V  e Grid Frequency 47 51 5Hz 57 61 5Hz    AC Wiring Procedure   Step 1  Make sure that the AC circuit breaker is switched off   Step 2  Dismantle the board with screwdriver     Step 3  Unscrew the waterproof terminal in the direction shown in the following  picture     ad                rs    step 2       E       y Step 3         Step 4  Insert the cables via the holes of the AC terminals   Step 5  Pull the cable from the other side     Step 6  Strip off insulation layer of all AC cables  The length of strip insulation is  approximate 10mm     28    Electrical Connection    Step 6 t  Step 5 t    LL  fl    Step 7  Press down the two red latches of inner AC connector                             Step 8  Pull inner AC connector outside     Step 7                                     29    JSIOKTL 12KTL 15KTL User Manual  Step 10  Plug the section above into the fixed terminal inside the inverter   Step 11  Fasten the board     Step 12  Screw the waterproof terminals in the direction shown in the following  picture                    Step 11      
33. nghai  200063 Ching  Tel  86 21 54259997    Emailsalesiijalponer com    75    
34. nverter converts DC power generated from the PV arrays into stable AC current   and then feeds this into the utility grid  The grid is three phase four wire type or  three phase five wire type  Inverter is crucial unit in the small scaled PV power  system     An example about intended use of this inverter is show in Fig 2 1                                         Fig 2 1 Inverter Applied in the PV Power System    gi IR       A WARNING     Any other or additional use is not permitted except the intended use     The inverter must only be connected to public utility grid     Installation    A WARNING     If output of inverter is connected to local loads  household appliance  lights     motor loads  etc    the inverter will stop working                                               2 2 Main Circuit    Following shows the main circuit of JSI15KTL    a transformerless    grid connected inverter  JS  OKTL and JSI12KTL have the similar main circuit     There are two MPP trackers designed for input  The boost stage levels up the input  DC voltage to a desirable value for the inverter  Then an IGBT three level inverter  circuit converts the DC power to AC power  This AC power is fed into the utility grid via    AC EMI filter     DC Switch    Fa    1    l I  l I  l I  l I  l I  l I       AS SSS SS           IGBT Three   level Inverter  Circuit        AC  EMI  Filter                Fig 2 2 Main Circuit Diagram of Inverter    2 3 Features of JSI 10K 12K 15KTL    The following are technica
35. ong press button O   to enter its submenu     7 9 2 Set Time       Language 0  bu   0  Spanish 1  Italy  2  Chinese 3  English  4  German 5  French  6  Japanese 7  Korea          Pa BA 000kW  125  IE 125 coxwn    497600 kWh  ES EN rn      2009 11 18 18 35          Run inform  His inform  Start Stop      gt  Set param             Set param    Password  1111            gt  Sys param  Run param  Pro param  Com param       Language      Time  Energy ad   Load default          55    Menu Operation    9  Short Press button    0  or    0   to set the number of language   10  And then long press button     gt  to confirm the choice     1  Long press button O  to enter  into the main control menu in the    default menu     2  Short press button Q  to move  arrow to    Set param        3  And then long press button O   to enter into its submenu     4  Short Press button O  or O   to input correct password     5  Short press button Q  to move  arrow to    Sys param        6  And then long press button O   to enter into its submenu     7  Short press button  9  to move  arrow to  Time      8  And then long press button O   to enter into the submenu     JSITOKTL 12KTL 15KTL User Manual       Time  Date  09 11 18  Time 18 35 55       9  Short Press button        or    0   to set date and time according to  you local time    10  And then long press button     0  to confirm     7 9 3 Setting Total Generated Power Adjustment       ben   EN 125 60kWh    497600 kWh    2009 11 18 18 35          
36. other electrical and electronic equipments  must be taken into consideration     A WARNING     Risk of damage to the inverter due to improper modification     Never modify the inverter or other components of the inverter  Otherwise it will  lead to loss of any and all warranty right     A WARNING     Any malfunction that can impair inverter safety must be repaired immediately  before the inverter is switched on again     A WARNING     Please contact your local authorized personnel if any maintenance is required     JSIOKTL 12KTL 15KTL User Manual    A WARNING     Electrostatic discharge can damage the inverter     During replacing or installing the inner components  the technical personnel  should take appropriate protective measures such as electrostatic bracelet     CAUTION     All safety instructions and warning labels on the inverter body    e Must be clearly visible    e Must not be removed  covered  pasted    CAUTION     These regulations should also be followed   e The regulations related to the electricity fed into the grid    e The safety instructions related to the PV arrays       Product Overview  m   s    About this Chapter    This chapter introduces intended use  main circuits  features and its constituent parts     JSITOKTL 12KTL 15KTL User Manual    2 1 Intended Use    Thank you for purchasing an inverter from Jalpower Company  JSI1OKTL  JSI12KTL  and JSI15KTL serial inverters are grid connected  transformerless  robust and high  conversion efficiency     The i
37. p 3  Dismantle inverter in the reversed direction of    Installation procedure      Step 4  Refasten the four fixed screws on the back of the inverter   Step 5  Dismantle the metal panel which holds the fans    Step 6  Disconnect the connection of the fan    Step 5  Replace the broken fan    Step 6  Reinstall the install onto the wall    Step 7  Re connect the inverter     Step 8  Restart up the inverter   8 2 3 Clean Air Inlet and Outlet    There is huge heat generated in the process of running  Inverter adopts controlled  forced air cooling method     In order to maintain good ventilation  please check there is something blocking the air  inlet and outlet     Clean the air inlet and outlet with soft brush or vacuum cleaner     67    JSIVOKTL 12KTL 15KTL User Manual    68       Technical specification  m   s    About this Chapter    This chapter illustrates technical data  including input data  output data  system   display and communication and mechanical data     69    JSIVOKTL 12KTL 15KTL User Manual    Max  DC 1000V  Voltage    Input Data    1000V 1000V    MPP Voltage    250 800V 250 800V 250 800V    Range       Max  DC 10 4kW  Power    12 5kW 15 6kW    40A  20A 2  40A  20A 2  40A  20A 2     Max  Input  Current    Recommend 700V 700V 700V    PV Array Open  Circuits  Voltage    Rated output  power       Output Data    10kW 12kW 15kW    Rated Grid  Voltage    400V 400V 400V       Grid Voltage 310 450V 310 450V 310 450V    Range    Rated Grid  Frequency    50 60Hz 50 60Hz 5
38. password     Password  1111    5  Short press button O  to move  Sys param arrow to    Run param          gt  Run param    Pro param l      Com param 6  And then long press button    to enter into the submenu        7  Short Press button O  or O     Standby time 010s to set running parameters   Recover time 030s o  Limit  p 100  8  And then long press button   2       to confirm the setting           NOTE       Standby time    is the time from inverter starting to initialize to inverter feeding power to  grid  This parameter ranges from 10s to 255s  And the default value is 10s        Recover time    is the time from the point that the fault is cleared to inverter recovering  to feed power to grid  This parameter ranges from 30s to 300s  And the default value  is 30s     7 9 6 Set Protecting Parameter         1  Long press button O  to enter    ea into the main control menu in the  GED    own default menu   497600 kWh  ES EN an      2009 11 18 18 35            2  Short press button  9  to move  arrow to  Set param         Run inform  His inform  Start Stop       gt  Set param        3  And then long press button O   to enter into its submenu               99    JSIOKTL 12KTL 15KTL User Manual    4  Short Press button O  or      Set param to input correct password     Password  1111    5  Short press button  9  to move  Sys param arrow to    Pro param      Run param     gt  Pro param l      Com param 6  And then long press button    to enter into the submenu        7  Short Pr
39. press button O   to enter into the submenu     4  Short Press button O  or 0   to input correct password     5  Short press button  0  gt  to  move arrow to  Com param      6  And then long press button O   to enter into the submenu     7  Short Press button O  or O   to set communication parameters     8  And then long press button O   to confirm the setting     And the baud rate of serial communication should be set 9600     61    JSIVOKTL 12KTL 15KTL User Manual    62       Troubleshooting and Maintenance  AN    About this Chapter    This chapter illustrates troubleshooting and dailv maintenance     63    JSITVOKTL 12KTL 15KTL User Manual    8 1 Troubleshooting    8 1 1 Troubleshooting of LED Indicator    See    Table 5 1LED Indicator Description    to see description of LEDs state     Type of fault Troubleshooting    LED indicators and LCD   Disconnect AC circuit breaker     cannot be lit   Rotate DC Switch to    OFF    position       Check the polarity of DC input        RUN    indicator goes out   Disconnect AC circuit breaker       Rotate DC Switch to    OFF    position      Check the correctness of electrical connection of inverter   See 4 Electrical       4  Check whether the voltage of DC input exceeds start up  voltage of inverter   5  Check whether the grid condition meets the demands  See     Table 7 2 Range of Protecting Parameters      6  If all above conditions are OK  please contact Jalpower  See       10 2 Contact Us         Fault    indicator is lit 1  Ther
40. ter    Rape into the main control menu in the  GED 125 conwn default menu     497600 kWh  State   Sa aun      2009 11 18 18 35             2  Short press button  9  to move        Run inform arrow to  Set param     His inform   Start Stop O   3  And then long press button      gt  Set param        to enter into the submenu           57    JSIOKTL 12KTL 15KTL User Manual    Set param    Password  1111      gt  Sys param  Run param  Pro param  Com param          Language  Time  Energy ad       Load default       Load default  Password  1111             7 9 5 Set Running Parameter       ance  EN 125 60kWh    497600 kWh  2       2009 11 18 18 35             Run inform  His inform  Start Stop      gt  Set param          58    4  Short Press button O  or O   to input correct password     5  Short press button O  to move  arrow to    Sys param        6  And then long press button O   to enter into the submenu     7  Short press button  9  to move  arrow to    Load default        8  And then long press button O   to enter into the submenu     9  lt is needed to input correct  password again  Short Press    button O  or O  to input the  password    10  And then long press button    O   to confirm     1  Long press button   O to enter  into the main control menu in the  default menu     2  Short press button  9  to move  arrow to  Set param      3  And then long press button O   to enter into its submenu     Menu Operation    4  Short Press button O  or      Set param to input correct 
41. ther end of RS485 cable  labled A and B  connected to  corresponding lines of RS485 bus  as the above diagram     Step 4  Connect other inverters to RS485 bus in the same way     Step 5  At the end of RS485 bus  connect RS485 A cable to  RX   port of  RS232 RS485 converter and connect RS485 B cable to  TX   port of RS232 RS485  converter     Step 6  Connect RS232 port of RS232 RS485 converter to RS232 port of PC     36       LCD Panel and DC Switch        s    About this Chapter    This chapter proposes parts that user can operate      LCD panel and DC Switch     37    JSIHOKTL 12KTL 15KTL User Manual    5 1 LCD Panel    LCD panel comprise LED indicators  buttons and LCD screen  Leds indicate the  current state of the inverter  The current running information and history information  can be seen in the LCD screen with operating the buttons     125 6kWh    497600 kWh  20    6 8 14  2009 11 18 18 35       Fig 5 1 LCD Panel    5 2 LED Indicator    There are two LED indicators     RUN    and    FAULT    respectively  User can observe  these leds to get the current state     Table 5 1 LED Indicator Description    Inverter is not running      EAULT    A malfunction occurs  A malfunction doesn t occur        5 3 Buttons    There are two buttons on the panel as Fig 5 1 shows  They are Q and O      38    LCD Panel and DC Switch    Table 5 2 Description of Button Function    Press less than two seconds Move to last row  or move to previous page  or  increase setting value     Press mor
42. ton    O  to enter into its submenu     6  Short press button O  to  move arrow to the time you want    to verify     7  And then long press button       9    to enter into its submenu        52    Menu Operation    Bus high The inner DC bus boost output  voltage is too high    Bus low The inner DC bus  boost output voltage is too low    Samp ft Malfunction occurs in the sampling circuit  DC Inject Output Current DC component is too high    NOTE    The inverter can only store at most 20 latest fault records        53    JSIHOKTL 12KTL 15KTL User Manual    7 9 Parameters Setting    NOTE    If you want to set inverter s parameters  you have to input correct password     The default password is 1111     7 9 1 Set Language       sepia  EN 125 60kWh    497600 kWh    2  2009 11 18 18 35          Run inform  His inform  Start Stop    gt  Set param                Set param    Password  1111            gt  Sys param  Run param  Pro param  Com param           Language  Time  Energy ad   Load default       54       1  Long press button    to enter  into the main control menu in the    default menu     2  Short press button  9  to move  arrow to    Set param        3  And then long press button O   to enter into its submenu     4  Short Press button O  or O   to input correct password     5  Short press button Q  to move  arrow to    Sys param        6  And then long press button O   to enter into its submenu     7  Short press button  0 to move  arrow to    Language        8  And then l
43. utton O  to enter    into the    Contrast adj    menu in the  default menu     2  Short Press button O  or O  to set  contrast value     1 is the minimum value and 100 is the  maximum     JSI 10KTL 12KTL 15KTL User Manual    7 A Start Inverter    NOTE    If conditions of DC side and AC side meet demands  or if malfunction is solved  the    inverter will start to run automatically     If you perform command    Stop    and want to restart again  it is needed to perform    command    Start        15 000kW           GD 125 coxwn  497600 kWh  2    2009 11 18 18 35                Run inform  His inform      gt  Start Stop  Set param              Start    Stop             Start Confirm            48    1  Long press button    to enter  into the main control menu in the    default menu     2  Short press button  Q  to move  arrow to    Start Stop        3  And then long press button O   to enter into its submenu     4  Short press button O  to move  arrow to    Start        5 And then long press button O     to enter into the submenu     6 Long press button O  to confirm     Start    command     7 5 Stop Inverter    NOTE    Menu Operation       Stop    command will switch off AC relay  It is needed to perform    Start    command to    restart the inverter        15 000kW           IEE 125 coxwn  497600 kWh       2009 11 18 18 35             Run inform  His inform      Start Stop  Set param          Start        Stop    Stop Confirm               1  Long press button O  to enter  into
44. while and observe  whether fault can be cleared by the inverter itself     2  Otherwise perform the command    Stop    or rotate DC switch to     OFF    position     3  Perform the command    Start    to restart the inverter or rotate  DC switch to    ON    position     4  If this malfunction still exists  please contact Jalpower  See     10 2 Contact Us           8 2 Maintenance    A WARNING     Disconnect the connection between inverter and grid and then the connection  between inverter and PV arrays before any maintenance work     Lethal voltage still exists in the inverter  Please wait at least five minutes and  then perform maintenance work     8 2 1 Clean Fan    There are four fans in the inverter  They are used for ventilation  It is suggested that  fans are cleaned every half year     Procedure    Step 1  Disconnect the connection of input and output side    Step 2  Wait at least five minutes    Step 3  Dismantle inverter in the reversed direction of    Installation procedure      Step 4  Refasten the four fixed screws on the back of the inverter    Step 5  Clean the fan with soft brush or vacuum cleaner    Step 6  Reinstall the install onto the wall     66    Troubleshooting and Maintenance    Step 7  Re connect the inverter     Step 8  Restart up the inverter   8 2 2 Replace Fan    If there is    Tem flt    and abnormal noise  please replace the fan   Procedure    Step 1  Disconnect the connection of input and output side    Step 2  Wait at least five minutes    Ste
    