Home

Ilumipanel 28 IP Optic RGB User Manual Rev. 6

image

Contents

1. CRI should be considered as one point of reference among others in evaluating white LED products and systems The following is an excerpt of recommendations from the DOE 1 Identify the visual tasks to be performed under the light source If color fidelity under different light sources is critically important for example in a space where color or fabric comparisons are made under both daylight and electric lighting CRI values may be a useful metric for rating LED products 2 CRI may be compared only for light sources of equal CCT This applies to all light sources not only to LEDs Also differences in CRI values of less than five points are not significant e g light sources with 80 and 84 CRI are essentially the same 3 If color appearance is more important than color fidelity do not exclude white light LEDs solely on the basis of relatively low CRI values Some LED products with CRIs as low as 25 still produce visually pleasing white light 4 Evaluate LED systems in person and if possible on site when color fidelity or color appearance are important issues Source DOE publication PNNL SA 56891 January 2008 28 IP Optic RGB User Manual Rev 7 15
2. Maximum resistance of 20 ohms 1000 ft Nominal impedance 100 140 ohms Signal Distribution Connect the bare ended signal cable from the product to a signal distribution box as indicated below Pin1 Common shield Pin 2 Data In black Pin 3 Data In white Pin 4 Data Out green Pin 5 Data Out red Junction 4 Junction box Conduit or DBC box 6 28 IP Optic RGB User Manual Rev 7 Wiring diagram DATA IN OUT Ground Pin 1 shield Data input Pin 2 black Data input Pin 3 white Data output Pin 4 green Data output Pin 5 red POWER IN Ground Live L Black Neutral N White Mounting Orientation This fixture may be mounted in any safe position Rigging Mount the fixture using the 4 mounting points When selecting installation location take into consideration programming adjustment s and routine maintenance When mounting the fixture be sure that the location can support the weight of the fixture 28 IP Optic RGB User Manual Rev 7 atad 4 OPERATING INSTRUCTIONS Menu Map llumicode remote addresser MAIN FUNCTION SUB FUNCTION SELECTION INSTRUCTION DMX address 001 512 Sets the DMX starting address Remote For use with optional controller see website for more information Personality ARC 1 3 channel RG
3. an RMA please include the following information on a piece of paper inside the box 1 Your name N Your address A O Your phone number The RMA 5 A brief description of the symptoms Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of merchandise It is the customer s responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping Any other claim for items such as missing component part damage not related to shipping and concealed damage must be made within seven 7 days of receiving merchandise Ilumipanel 28 IP Optic RGB User Manual Rev 7 USA WORLD HEADQUARTERS General Information ILUMINARC Address 5200 NW 108th Avenue Sunrise FL 33351 CONTACT Us Voice 954 923 3680 Fax 800 544 4898 EUROPE General Information Chauvet Europe BVBA Address Stokstraat 18 9770 Kruishoutem Belgium Voice 32 9 388 93 97 General Information Chauvet Europe Address Unit 1C Brookhill Road Industrial Estate Pinxton Nottingham UK NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 General Information Chauvet Mexico Address Av Santa Ana 30 Parque Industrial Lerma Lerma Mexico C P 52000 Voice 52 728 285 5000 ILUMINARC I NP Technical Support Voice 800 762 1084 Email support iluminarc com World Wide Web www i
4. mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens Gently polish optical surfaces until they are free of haze and lint The cleaning of external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Returns Procedure Claims 12 Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without an RMA will be refused Call ILUMINARC and request RMA prior to shipping the fixture Be prepared to provide the model number serial number and a brief description of the cause for the return Be sure to properly pack fixture any shipping damage resulting from inadequate packaging is the customer s responsibility ILUMINARC reserves the right to use its own discretion to repair or replace product s As a suggestion proper UPS packing or double boxing is always a safe method to use Note If you are given
5. 28 IP Optic RGB User Manual Rev 7 ILUMINARG 5 APPENDIX DMX Primer There are 512 channels in a DMX 512 connection Channels may be assigned in any manner A fixture capable of receiving DMX 512 will require one or a number of sequential channels The user must assign a starting address on the fixture that indicates the first channel reserved in the controller There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required Choosing a start address should be planned in advance Channels should never overlap If they do this will result in erratic operation of the fixtures whose starting address is set incorrectly You can however control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation In other words the fixtures will be slaved together and all respond exactly the same DMX fixtures are designed to receive data through a serial Daisy Chain A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture Use an order that provides for the easiest and most direct cabling Connect fixtures using shielded two conductor twisted pair cable The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive
6. B color mixing ARC 1 D 4 channel RGB dimmer ARC FULL 7 channel RGB dimmer Color Macro Strobe White 1 11 Red Green Edit white color of different color temperatures Blue i 0 255 Calibration 868 Red Green Modify RGB dim to White values Blue 0 255 Off No function Dim1 Dimmer Dim2 Select between 4 dimmer curves for the fixture Dim3 Dim4 Red Static Sa Combine the different attributes to create a static Strobe 0 20 Hz 50800 0 255 Operation This fixture requires the llumicode remote addresser to change the starting address change the personality change the dimming curve or to set the fixture to operate on a static program Please see the below instructions for this process gt N 5 Plug the Ilumicode into the DMX in Press the power button Modify the settings as desired Press the enter key after each setting modification The fixture should light green when a setting has been successfully changed and remain lit for 15 seconds You must press ENTER after each setting modification in order to properly send the setting to the fixture You may only modify a maximum of up to 20 fixtures at a time with the Ilumicode However each fixture that is attached will have the same identity In order to have individual addressing connect 1 fixture at a time The Ilumicode will automatically power off after being idle for 1 minute Ilumipanel 28 IP Optic RGB User Manual Rev 7 DMX Chan
7. Ilumipanel 28 IP Optic RGB User Manual LUMINARC Edition Notes The Ilumipanel 28 IP Optic RGB User Manual Rev 7 covers the description safety precautions installation programming operation and maintenance of the Ilumipanel 28 IP Optic RGB ILUMINARC released this edition of the Ilumipanel 28 IP Optic RGB User Manual Rev 7 in November 2015 Trademarks The ILUMINARC logo the ILUMINARC name and all other trademarks in this document related to services or products by ILUMINARC are trademarks owned or licensed by ILUMINARC its affiliates or subsidiaries Any other product names logos brands company names or trademarks featured or referred to within this document are the property of their respective trademark holders Copyright Notice The entire content of this document except where applicable and unless otherwise noted is solely owned by ILUMINARC a wholly owned trademark of Chauvet amp Sons Inc Copyright 2015 ILUMINARC All rights reserved Electronically published by ILUMINARC in the United States of America Manual Usage ILUMINARC authorizes its customers to download and print this manual for professional information purposes only ILUMINARC expressly prohibits the usage copy storage distribution modification or printing of this manual or its content for any other purpose without its written consent Document Printing For better results print this document in color on letter si
8. S Setting the Starting Address This DMX mode enables the use of a universal DMX controller device Each fixture requires a start address from 1 to 512 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that uses 6 DMX channels and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 and 105 Choose start addresses so that the channels used do not overlap and note the start address selected for future reference If this is your first time addressing a fixture using the DMX 512 control protocol we suggest jumping to the Appendix Section and reading the heading DMX Primer It contains very useful information that will help you understand its use 28 IP Optic RGB User Manual Rev 7 11 maintain optimum performance minimize wear fixtures should be cleaned frequently Usage and environment are contributing factors in determining frequency As a general rule fixtures should be cleaned at least twice a month Dust build up reduces light output performance and can cause overheating This can lead to reduced LED life and increased mechanical wear Be sure to power off fixture before conducting maintenance Use a soft brush to remove dust collected on external surface Clean all glass when the fixture is cold with a
9. her in printed or electronic format and replace them with this version Ilumipanel 28 IP Optic RGB User Manual Rev 7 ILUMINAR Table of Contents 1 BEFORE YOU BEGIN INHATIS INCLUDEDL ARR Aero se fre a AS AT AE ol ENT pi ia die pui pu UNPACKING INSTRUCTIONS AC POWER Power Distribution SAFETY INSTRUCTIONS 2 INTRODUCTION IL le pia ed bbl ed yeaa a wat a ig oa gah ice OS ae a 3 DMX CHANNEL SUMMARY 3 SR A RENE 4 3 lt 223 33_ 2 _3__ 4 CREA ILARIA ER AN NN a 5 3SETUP_ O A E AAI I A EEE E ATE E E E A E O A 5 FIXTURE LINKING A A a aa 6 DATA CABLING S A 6 DMX Data Cable 2 6 Signal Distribution WIRING DIAGRAM Orientation _______3 lt _3 __ _3_ __ __ __ _ ___ __ ___ _ __ inke 8 _ __ __ _ __ _ _ _ _ __ ____ _ __ _ _ 8 Op rations
10. hey also receive this instruction booklet CAUTION When transferring product from extreme temperature environments e g cold truck to warm humid ballroom condensation may form on the internal electronics of the product To avoid causing a failure allow product to fully acclimate to the surrounding environment before connecting it to power Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on the decal or rear panel of the fixture Secure fixture to fastening device using a safety chain Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Never connect the device to a dimmer pack Make sure the power cord is never crimped or damaged Never disconnect the power cord by pulling or tugging on the cord Avoid direct eye exposure to the light source while it is on There are no user serviceable parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please contact ILUMINARC at 954 923 3680 ext 4000 After prolonged
11. i Seta gtd ad 8 VIIMII3MM V 9 ARC FULL 28 IP Optic RGB User Manual Rev 7 ILUMINARG 3 lt 3 _ _ __3333 70 11 PMX PRIER TER 11 Selling the StaninG Add _ 11 2222 2 2222222 22 lt lt lt __ 12 RETURNS PROCEDURE 12 e a i a ata 12 lt lt lt lt __ 23533 66 _ ERROR BOOKMARK NOT DEFINED TECHNICALS PECIFIGATIONS 14 iv Ilumipanel 28 IP Optic RGB User Manual Rev 7 ILUMINARG 1 BEFORE YOU BEGIN What is Included y 1 x Ilumipanel 28 IP Optic RGB 1 X Warranty y 1 x User Manual Unpacking Instructions Immediately upon receiving a fixture carefully unpack the carton check the contents to ensure that all parts are present and have been received in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling Save the carton and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original fact
12. luminarc com Technical Support Email Eutech chauvetlighting eu World Wide Web www chauvetlighting eu Technical Support Email uktech iluminarc com World Wide Web www chauvetlighting co uk Technical Support Email servicio iluminarc com mx World Wide Web www chauvet com mx Outside the U S United Kingdom Ireland Mexico or Benelux contact the dealer of record Follow their instructions to request support or to return a product Visit our website for contact details 28 IP Optic RGB User Manual Rev 7 ILUMINARG 14 Technical Specifications WEIGHT amp DIMENSIONS Length iaia 11 1 in 283 mm 3 4 in 87 mm Height 9 3 in 235 mm lt lt 3_3 lt 3 lt _ 2 ___3 _ __ _ ___3_ __ _ _ _ 6 5 lbs 3 kg LIGHT SOURCE LED 28 x 1 W 350 mA 10 red 9 green 9 blue 50 000 hrs ELECTRICAL SPECIFICATIONS Autoswitching internal power supply 100 240 VAC 50 60 Hz Power consumption 115 60 Hz 33 W 0 5 A Power factor 115 60 HZ sin en nm aria 0 55 Power consumption 230 60 2 36 W 0 31 A Power factor 230 60 HZ save 0 53 Anaao aaa Cast aluminum REMOTE ADDRESSER I 44444001 ORDERING DETAILS Ilumipanel 28 IP O
13. nel Values ARC FULL CHANNEL VALUE FUNCTION 1 Dimmer 0000 255 0 100 2 Red 000 U 255 0 100 3 Green 0000 255 0 100 4 Blue 0000 255 0 100 Color Macro 0000 010 function 0110 035 100 Green up Blue 0 036 060 down Green 100 Blue 0 0610 085 0 Green 100 Blue up 086 0 110 Red 0 Green down Blue 100 1110 135 Red up Green 0 Blue 100 1360 160 Red 100 Green 0 Blue down 1610 185 100 Green up Blue up 5 1860 210 Red down Green down Blue 100 2110 215 White 1 3200K 2160 220 White 2 3400K 2210 225 White 3 4200K 226 0 230 White 4 4900K 231 235 White 5 5600K 236 U 240 White 6 5900K 241 0 245 White 7 6500K 246 250 White 8 7200K 251 0 255 White 9 8000K Strobe 6 10000 004 function 005 U 255 Strobe slow fast Dimming Speed 0000 009 Off 9 0100 069 Speed 1 fastest 0700 129 Speed2 1300 189 Speed3 1900 255 Speed4 slowest 28 IP Optic RGB User Manual Rev 7 10 ARC 1 CHANNEL VALUE FUNCTION 1 0000 255 10 10090 2 000 255 0 100 3 Blue 000 255 0 100 ARC 1 D CHANNEL VALUE FUNCTION 1 Dimmer 000 255 0 100 2 0000 255 10 10090 3 Green 000 255 0 100 4 Blue 000 255 0 100 Solid CHANNEL VALUE FUNCTION 000 0 255 Dimmer 0 10096 Ilumipanel
14. ory box and packaging AC Power This fixture has an auto ranging power supply that can accommodate a wide range of input voltages The only thing necessary to do before powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This fixture will accommodate between 100V and 240V AC 50 60 Hz All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for 0 to 100 switch Warning Verify that the voltage input on your unit matches the line voltage applied Damage to your fixture may result if the line voltage applied does not match the voltage indicated on the voltage input All fixtures must be connected to circuits with a suitable Earth Ground Power Distribution Connect the bare ended power cable from the product to a power distribution box as indicated below From To fuse other panel boxes L Junction Junction box Conduit or box DBC 28 IP Optic RGB User Manual Rev 7 1 Please read these instructions carefully which includes important information about the installation usage and maintenance of this product Caution Caution Please keep this User Guide for future consultation II you sell the unit to another user be sure t
15. ows of one or more fixtures using a DMX 512 controller or to run synchronized shows on two or more fixtures The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Important Fixtures on a serial data link must be daisy chained in one single line To comply with the EIA 485 standard no more than 32 devices should be connected on one data link Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal Note USITT recommends limiting the total length of the DMX cable from the first fixture controller to the last fixture to 300 455 m 985 1 500 ft The maximum recommended number of fixtures ona Serial data link is 32 fixtures Data Cabling To link fixtures together you must obtain data cables If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DMX Data Cable Use a Belden 9841 or equivalent cable which meets the specifications for EIA RS 485 applications Standard microphone cables cannot transmit DMX data reliably over long distances The cable will have the following characteristics 2 conductor twisted pair plus a shield Maximum capacitance between conductors 30 Maximum capacitance between conductor and shield 55 pF tt
16. periods of operation the fixture chassis may reach high temperatures Use caution when handling this fixture The RDM2go which includes a built in ilumicode addresser along with many other useful features is now available The addresser is required for product configuration sold separately Ilumipanel 28 IP Optic RGB User Manual Rev 7 2 INTRODUCTION DMX Channel Summary The 28 IP RGB has multiple personalities which can be changed using the remote addresser There are 4 personalities ARC FULL CHANNEL FUNCTION 1 Dimmer 2 Red 3 Green 4 Blue 5 Color Macro 6 Strobe 7 Dimming Speed ARC 1 CHANNEL FUNCTION 1 Red 2 Green 3 Blue ARC 1 D CHANNEL FUNCTION 1 Dimmer 2 Red 3 Green 4 Blue Solid CHANNEL FUNCTION 1 Dimmer 28 IP Optic RGB User Manual Rev 7 3 ILUMINARG Product Overview Power in DMX in out Safety cable attachment Front of fixture I J el 4 L Mounir bracket Bracket adjustment Cable tie location 28 IP Optic RGB User Manual Rev 7 ILUMINARC Product Dimensions Length AL VA C XX ZE 28 IP Optic RGB User Manual Rev 7 5 ILUMINARG 3 SETUP Fixture Linking You will need a serial data link to run light sh
17. ptic 15 RGB gray housing llumipanel 28 IP Optic 30 RGB gray housing 13028002 13028001 WTERTE CONFORMS TO UL STD 1573 CERTIFIED TO US csa STD 22 2 LISTED No 166 3144482 Ilumipanel 28 IP Optic RGB User Manual Rev 7 ILUMINARG LED Life ILUMINARC rates LED lifetime based on lumen depreciation of 70 of the original output with data provided by the manufacturer of the LED Data from the manufacturer of the LED are not independently verified or measured by ILUMINARC When the fixture is operating in optimal environmental conditions the LED lifetime is rated to be 50 000 to 70 000 hours by the LED manufacturer LED Binning LED manufacturers sort LEDs into bins based on variances in color output intensity and the frequency at which the semiconductor operates ILUMINARC strives to hold its LED manufacturers to the highest standards of binning to optimize consistency in output from fixture to fixture However the availability of a single bin cannot be guaranteed With that in mind ILUMINARC has developed a rigorous control system to seek the best achievable consistency in color and output Color Rendering Index CRI CRI is an industry standard method to compare properties of different types of light sources There are known limitations and inconsistencies related to CRI Results may vary depending on the environmental factors involved For this reason the US Department of Energy DOE states that
18. ze paper 8 5 x 11 inches double sided If using A4 paper 210 x 297 mm configure your printer to scale the content of this document to A4 paper Intended Audience Any person in charge of installing operating and or maintaining the Ilumipanel 28 IP Optic RGB should read the Guide that shipped with it and this manual in their entirety before installing operating or maintaining this product Disclaimer ILUMINARC believes that the information contained in this manual is accurate in all respects However ILUMINARC assumes no responsibility for any error or omissions in this document ILUMINARC reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of ILUMINARC to notify any person or company of such revision or changes This does not constitute in any way a commitment by ILUMINARC to make such changes ILUMINARC may issue a revision of this manual or a new edition of it to incorporate such changes ILUMINARC Publications Hot Line If you have any comments about the accuracy of this document or general suggestions regarding how we can improve it please call us at 954 923 3680 You can download the latest versions of all ILUMINARC products manuals from www iluminarc com Document Revision The Ilumipanel 28 IP Optic RGB User Manual Rev 7 supersedes all previous versions of this manual Please discard any older versions of this manual you may have whet