Home

Ethernet Communication Adapter User`s Manual

image

Contents

1. 000cc0008 8 Adding AUS CL otccinensoacsesonoestasensaniadoniaes 9 AMR timeout eee eee 16 Assigning IP address statically 13 Assigning IP address through DHCP OI Sl EE E 14 Automatic meter reading AMR 7 C Configuring Adapter Settings 13 Configuring User Setting 12 D DUC CP eea E 14 F Facotry reset 5 H aleinn iia A A 6 I VT Ee a o e EEEE TEE E 3 INS ta ATION aecccrcennesoseiecceacsprecsatasosenssess 4 IP address c ccc ceceeceecescescseeseeeee 8 13 M Module Setup ccccccccccsecccceeeeceenees 13 14 AA ED ED FPREDID MY NC LPT OS ena 12 O Overload protection ccccccceeeceeeeeees 3 R REMOVING users cccceeccceseeeeceeeeeeenees 10 PROSCL DOM erren 5 ISS FOL a canatosesensdorssenaiasecencreecoberers anes 3 RJ 45 Ethernet connector c 00008 3 S CAPS e E 3 DOTES Ol ore cons 5 SN eaer EE 6 Sas LED erronea 3 5 T Tenpera M O perosina aan i 6 Terminal for connecting power 3 Timeout configuration 16 Type designato fly s c ccrecnescntscnesioeainescaetens 4 U User Management 9 10 W WDR IV e EE eo ee ee 7 Web TIMGOUL sicirscceissastverersaseinvetcenderes 16 Page 18 of 18
2. temperature coefficient PTC thermistor for overload protection 2 PRODUCT DESCRIPTION The CEM 05000 Ethernet communication adapter is an ABB serial communication adapter product that enables automatic meter reading AMR of ABB electricity meter over a LAN network or the internet using standard Ethernet protocols TCP and UDP Like all other ABB serial communication adapters the ABB Ethernet communication adapter have the size of 2 DIN modules and follows the ABB s pro M standard which defines mechanical dimensions way of mounting 85 mm DIN rail and design outlook Furthermore the adapter follows and meets the safety requirements of DIN EN 50090 2 2 The ABB Ethernet communication adapter does also have a built in web server that provides easy access of meter data and simple adapter configuration with an ordinary web browser 2 1 PRODUCT OVERVIEW The different parts of the SCA are depicted below Figure 1 SCA parts RJ 45 Ethernet connector Reset port Label with the type designation and MAC address Terminal for connecting power Infra red communication port Teoh AA ED ED FALDID Page 3 of 18 6 Status LED 2 2 TYPE DESIGNATION Below are tables with explanation for all positions in the type designation for the SCA Type Media Protocol Supply voltage Optional functionality Table 1 Type designation of ABB Serial Communication Adapters 3 INSTALLATION 1 Dis
3. A ED ED FADED Ethernet Communication Adapter CEM 05000 Users Manual Rev B1 ABB AB P O Box 1005 SE 611 29 NYKOPING Sweden Tel 46 155 295000 Fax 46 155 288110 AL ED ED FALDID Page 1 of 18 Table of Contents Ll CENERI D oeenn E E E E E E 3 2 PRODUCT DESCRIP HON scaccia a csucentsoaocasssccusustaoereessroeases 3 2 1 PRODUCT OVER VIE erriren enep Rene Ca O E E EOE E E EEO EP Eana 3 Dee ANE DE TONA TION aaa a a A E E E Giestnnsste 4 S IN PALLATI ON e E E EE E E a 4 3 1 edk uni oa z D A E E E E E 5 A FROUBLE SHOOTIN G oevrsssssscasscssscesscassscascsasccesceavecescensseescwassawasoasseesseassteccsssneaceees 5 AR POR ea nao ses gators nee autre E E E couse taatpsesd qatertauce 5 4 1 1 0 TOS 2 a E EE E E E eer ee eter 5 4 1 2 E a 1 EEEE EEO ENE E EAT 5 5S TECHNICALDALA wissccssiscsscssccscsessscacesescsecssesaececsteatescssvanssceavesvascascansqoascsscoonsweascors 6 57A TIT NS LOIN E E E E enter 7 6 AUTOMATIC METER READING wisiisisisiscscssssicssscateccssssciccsosntaccsnssaiaccasateaceaventaces 7 7 TOER Vy RG iar eat cetineseccet a E E E 7 A FRCCES SING Wy SB irate peed rete cara eet erent eatin emcee sens cance eee 8 T4 USER MANAGEMENT arenes cass ceteces a rikene Eo Aer E aA E RE ERE NS ESENTE 9 7 2 1 FOG USF E ash E E E E E E sone S A E 9 Ta PONOVO US CVS n A E A E E E A EA 10 Jalad COMICS User SUIS assas senn EnEn aera 2 7 3 CONFIGURING ADAPTER SETTINGS seeeesessssssseeeresssssssseeere
4. connect the power supply 2 Strip the wires and connect them to the top terminals of the SCA 3 Connect the Ethernet cable to the RJ 45 LAN interface of the SCA which is located on the bottom of the SCA 4 Place the SCA to the left of the meter and snap it on the DIN rail 5 Verify that the SCA is correctly wired and the voltage is according to the technical specification before the power is turned on 6 Verify that the status LED is green to ensure link and that the power is on Figure 2 Installation of the SCA AL ED ED FALDID Page 4of 18 3 1 STATUS LED The status LED 1 of figure 1 indicates the state of the SCA The chart below describes the state of the SCA and how the status LED indicates this Status LED SCA Status Link has been established and OK Flashing Green Transferring data Transferring data No link established Red Fatal Error Table 2 Table over the status LED indication 4 TROUBLE SHOOTING Off No link Please check the connection of the network cable Off No power to SCA Please check the connection of the power line Red Csi Fatal err Please contact your dealer Table 3 Trouble shooting guide 4 1 RESET PORT The SCA is also equipped with a Reset port 7 in figure 1 which can be used to perform a soft reset or a factory reset Reset is performed by short circuit the two holes in the reset port Below follows a description over the different reset procedures and how these are
5. dit view Favorites Tools Help da Back mp x A SQ search 4Favorites cA Ea g E Meter Data My Settings User Management Module Setup The upload was successfull The device will be rebooted Please waitfor ten seconds ooo Page 15 of 18 7 3 3 TIMEOUT CONFIGURATION There are two kinds of timeouts that can be configured on the Ethernet communication adapters AMR and Web timeout These timeouts determines how long time the AMR or the Web server will have exclusive right to access the electricity meter Below follows an explanation of these and how they are configured AMR Timeout The AMR timeout is the time in which the AMR system has the exclusive right to access the electricity meter This means that the web server will not be able to access the electricity meter until the AMR timeout has timed out after an AMR access of the adapter By default the AMR timeout is set to 60 seconds Example if the AMR timeout is set to 60 seconds it means that the web server will only be able to access the values of the electricity meter 60 seconds after a performed AMR access of the electricity meter Web Timeout The Web timeout is the time in which the web server will have the exclusive right to access the electricity meter This means that the AMR system will not be able to access the electricity meter until the Web timeout has timed out after an access using the web server This parameter is set according to the prevailing netw
6. en seconds Ey Done a SS fas Local intranet a 7 3 2 ASSIGNING IP ADDRESS THROUGH DHCP SERVER Click on the Module Setup tab to enter the Module Setup Check the DHCP check box and click submit E ABB Electricity Meter Microsoft Internet Explorer provided by ABB File Edit View Favorites Tools Help qa Back mb E3 A SQ search Favorites EA Ed E Address http 192 168 1 10 Meter Data My Settings User Management Module Setup Module Setup Enable DHCP IP number Met mask Default gateway Port number M Bus TCP Port number M Bus UDP HTTP port number Meter identification Read from Meter Wiser defined AMR timeout ech Web timeout ech ta z ee a IMIM Page 140of18 Click Reboot to adopt the new settings E 466 Electricity Meter Microsoft Internet Explorer provided by ABE Eile Edit View Favorites Tools Help m Back mp Se Ai SGU search Favorites E E Z El Address http 192 168 1 10 Meter Data My Settings User Management Module Setup The new settings have been applied but a rebootis required to switch to the new settings Select the reboot button below to rebootthe system The reboot process willtake several seconds Reboot Local intranet The configuration of IP address through DHCP server has been set successfully and the adapter will reboot E ABB Electricity Meter Microsoft Internet Explorer provided by ABB File E
7. essssssseertessssssseeeeeees 13 ldd Assigning IP address statically 000nneonnneennannnnnnnssnnnssnnsssrnsssrrssserssers 13 ew Assigning IP address through DHCP server c e 14 T Timeout Configuration ossseeesnanensnnnnessennnseseeessstiessstesseseerseseersssrrsssen 16 8 ABBREVIATIONS AND ACRONYMS eesesssesocsseccosssecosssecosssesoosseseosseseosssesosoe 17 T INDEN o T N E EES 18 2006 2007 by ABB AB All rights reserved Trademarks Microsoft Internet Explorer Windows and Windows NT are registered trademarks of Microsoft Corporation Other brand and product names are registered trademarks or trademarks of their respective holders AA ED ED FPREDID Page 2 of 18 1 GENERAL This manual contains information about the CEM 05000 Ethernet communication adapter which is an adapter of the serial communication adapter SCA family for electronic electricity meters manufactured by ABB AB Throughout this manual the CEM 05000 Ethernet communication adapter will be referred to as the SCA or the adapter The purpose of this manual is to give the user a good overview and understanding of the features the CEM 05000 Ethernet communication adapter offers WARNING The voltages connected to the SCA are dangerous and can be lethal Therefore it must be insured that the terminals are not touched during operation When installing the SCA all voltages must be switched off Note The adapter is equipped with a positive
8. in web server except the features that are listed below e Load Profile Values e Maximum Demand e Voltage Event Log Please refer to the User s Manual of the electricity meter for more information of what quantities that can be readout depending on the type of electricity meter AA ED ED PFPRIEIDID Page 70f18 7 1 ACCESSING THE WEB SERVER This section will describe how to access the built in web server in ABB Ethernet communication adapter Open a web browser and type the IP address default 192 168 1 10 of the ABB Ethernet communication adapter in the web browsers address field about blank Microsoft Internet Explorer provided by ABE File Edit View Favorites Tools Help q Back p ie ay SE Search 4 Favorites a Eal zal bons eee tintermet O The page will appear like the one below The quantities of the electricity meter are located in the main frame of the browser and in the left frame are all telegrams in the electricity meter The quantities that appear will be different depending on the model of electricity meter B ABB Electricity Meter Microsoft Internet Explorer provided by ABE oJ x File Edit View Favorites Tools Help 4a Back m E3 i SE Search 4 Favorites Es Eee j Address lt http 192 168 1 10 Meter Data My Settings User Management Module Setup ABB Electricity Meter Serial Humber 00206041 Energy Active 1290 15 k
9. in with username and password http 192 168 1 10 Microsoft Internet Explorer provided by ABE Fie Edit View Favorites Tools Help 4 Back mp E3 AA SO Search 3eFavorites EA Eai A Address E http 192 168 1 10 iGo Ange natyverkslosenord Te Ange anvandamnamn och losenord Plats 192 168 1 10 Resurs ipweb Hamn admin L senord z Spara l senordet i losenardslistan CA E Opening page htkp ff192 166 1 10 EE Local intranet E 7 2 2 REMOVING USERS Click on the User Management tab and then use the arrow buttons to scroll to the user that shall be removed Click then remove ABB Electricity Meter Microsoft Internet Explorer provided by 466 File Edit View Favorites Tools Help 4 Back m fe Sy Search Meter Data My Settings User Management Module Setup List Users Add User Users Username admin Password Ta Change password True Access level Administrator Language en Change Remove Eq ES Sof Local intranet Page 10 of 18 Click OK when below dialog appear x y as A Meter Data My Settings User Management Module Setup List Users Add User Users Username Password Change password Access level Language 2 x e y ABB Electricity Meter Microsoft Internet Explorer provided by ABE we q gt 2 arl ES http y192 168 1 10 Meter Data My Settings User Management Module Se
10. low a j i a 090000 ae lela 58 g OOOO ABE 1 a CEM 05000 _Powet Ethernet M bus poon roo2gov fy efi SSS IN a O 1 il Wo Figure 3 The physical dimensions of the SCA 6 AUTOMATIC METER READING The ABB Ethernet communication adapter provides Automatic Meter Reading AMR using M Bus protocol over UDP or TCP through a LAN network or the internet This is done transparently without altering the original M Bus telegrams Please note that the shortest time between readouts is different depending on the type of the electricity meter please refer to the User s Manual of the electricity meter for more information 7 THE WEB SERVER Besides providing communication with an AMR system the ABB Ethernet communication adapter does also have a built in Web server that enables static meter reading over a LAN network or internet using an ordinary web browser The web server provides an easy interface to configure the settings of the adapter and its users and privileges The adapter s IP address can be assign either statically or dynamically by a DHCP server All quantities that can be readout by using the M Bus protocol on the AMR part of the adapter can be readout on the built
11. ork environment and should not to be set too long as the Ethernet adapter will block the AMR system to access the electricity meter until the Web timeout has timed out On the contrary by setting this parameter too short the AMR system can cut in and access the electricity meter before the web server has accomplished to do all it s readout of the meter This will lead to the consequence that the communication on the network will time out and the web server will not be able to read all the pages from the electricity meter Therefore the setting of the Web timeout should be set small enough to be able read all the pages of the meter and set large enough to keep the network communication alive By default the Web timeout is set to 120 seconds and should be increased if the Ethernet adapter is connected to a slow network Example if the Web timeout is set to 120 seconds it means that the AMR system will only be able to access the values of the electricity meter 120 seconds after an access of the web server PADDED Page 16 of 18 8 ABBREVIATIONS AND ACRONYMS 10BASE T DHCP IP IP Address LAN MAC address Mbps Netmask UTP AL ED ED FALDID IEEE 802 3 specification for 10 Mbps Ethernet over twisted pair wiring Dynamic Host Configuration Protocol An Ethernet protocol specifying how a centralized DHCP server can assign network configuration information to multiple DHCP clients The assigned information includes IP add
12. performed 4 1 1 SOFT RESET By performing a soft reset means to reset the SCA without restoring the settings of the adapter to the default factory settings To perform a soft reset short circuit the holes in the reset port with e g a paper clip for 10 seconds and remove the paper clip 4 1 2 FACTORY RESET By performing a factory reset means to reset the SCA and restore the settings of the adapter to the default factory settings To perform a factory reset short circuit the holes in the reset port with e g a paper clip for more than 40 seconds and remove the paper clip AL ED ED FALDID Page 5 of 18 5 TECHNICAL DATA Network Protocol and Standards Compatibility Data protocols TCP IP UDP DHCP Power Supply Nominal voltage 100 240 V AC Voltage range 20 to 15 of nominal voltage Frequency 50 60 Hz 5 Power consumption 0 80 VA at 230 V AC 50 Hz Terminal wire area 0 2 5 mm Recommended tightening torque 0 5 Nm Mechanical Data Casing material Polyamide Protection class IP 20 Weight 90 g Environmental Specifications Operating temperature range 40 C to 55 C Storage temperature range 40 C to 70 C Humidity 75 yearly average 95 on 30 days year Interface Specifications LAN 10BASE T 10 Mbps Connection interface RJ 45 Standards Safety DIN EN 50090 2 2 Ak ED ED FALDID Page 6o0f 18 5 1 DIMENSIONS The physical dimensions of the SCA are displayed be
13. resses DNS addresses and gateway router addresses Internet Protocol The main internetworking protocol used in the Internet Used in conjunction with the Transfer Control Protocol TCP to form TCP IP A four byte number uniquely defining each host on the Internet Ranges of addresses are assigned by Internic an organization formed for this purpose Usually written in dotted decimal notation with periods separating the bytes for example 192 168 1 10 Local area network A communications network serving users within a limited area such as one floor of a building A LAN typically connects multiple personal computers and shared network devices such as storage and printers Although many technologies exist to implement a LAN Ethernet is the most common for connecting personal computers Media Access Control address A unique 48 bit hardware address assigned to every Ethernet node Usually written in the form 00 03 47 D8 AE 3A Megabits per second A number that explains which part of an IP address comprises the network address and which part is the host address on that network It can be expressed in dotted decimal notation or as a number appended to the IP address For example a 28 bit mask starting from the MSB can be shown as 255 255 255 192 or as 28 appended to the IP address Unshielded twisted pair The cable used by 10BASE T and 100BASE Tx Ethernet networks Page 17 of 18 9 INDEX A Accessing the web Serve
14. tup List Users Add User Liserhas beed removed Page 11 of 18 7 2 3 CONFIGURING USER SETTING Login and click on the My Settings tab ABEB Electricity Meter Microsoft Internet Explorer provided by ABE File Edit Mier Favorites Tools Help lt Back gt O 2 Cy Qh graves B A amp Sl Address betpyi92 168 1 10 iGo Settings Liser name jadmin its Old Password i sisSz Mew Password i ttsti i zOY Retvpe Password a Language Engish Cance Ea Opening page Http f 192 166 1 10feu ABB Electricity Meter Microsoft Internet Explorer provided by ABB Fie Edit View Favorites Tools Help 4 Back m g3 A SQ search Favorites a4 Eh Eil Address http 192 168 1 10 Wiser data recieved AL ED ED FALDID Page 12 of 18 7 3 CONFIGURING ADAPTER SETTINGS This section will describe how to configure the ABB Ethernet communication adapter s IP address both statically and by a DHCP server 7 3 1 ASSIGNING IP ADDRESS STATICALLY Enter the Module Setup by clicking on the Module Setup tab Uncheck the Enable DHCP check box and enter the information for static IP address E ABB Electricity Meter Microsoft Internet Explorer provided by ABB File Edit View Favorites Tools Help qda Back mb E3 A SQ search Favorites cA Gi E Address http 192 168 1 10 r so Meter Data My Settings User Management Module Setup Module Set
15. up Enable DHCP D IF number fig2168110 Met mask 255 255 2550 Default gateway fig216811 Port number M BusiTCP eoz Fot number M BusfUDP jar HTTP port number o Meter identification Read form Meter D mI Wiser defined A AMF timeout secr 20 Wieb timeout secr 20 ll submit Clear El javascript loadAllFramest topFrame ftop info e lefkFrame fempty rightFrame Ymosp fas Local intranet ve Click Submit to continue and click Reboot when below screen appears a ABEB Electricity Meter Microsoft Internet Explorer provided by ABE 7 joj File Edit Views Favorites Tools Help lt Back ee Ai SCM Search Favorites ga Eh E Address E http 192 168 1 10 g ao Links Meter Data My Settings User Management Module Setup The new settings have been applied but a rebootis required ta switch to the new settings Select the reboot button below to reboatthe system The reboot process willtake several seconds Reboot faz Local intranet Ak ED ED FADED Page 13 of 18 The IP address has been set successfully and the adapter will reboot yy ABB Electricity Meter Microsoft Internet Explorer provided by ABE File Edit View Favorites Tools Help 4 Back m E3 i SG Search gFavorites ca Er A Meter Data My Settings User Management Module Setup The upload was successfull The device willbe rebooted Please waitfor t
16. wh Status value 1600 Power fail counter AL ED ED FALDID Page 8 of 18 7 2 USER MANAGEMENT This section will deal with the user management feature in ABB Ethernet communication adapter It will discuss how to add and remove users and setting their privileges and settings 7 2 1 ADDING A USER Enter the User Management menu and click then on the Add User tab Add user by filling in the fields below and submit Please note that once the password is set it is non recoverable therefore save the password and keep it in a safe place yy ABB Electricity Meter Microsoft Internet Explorer provided by 466 File Edit View Favorites Tools Help 4a Back mm iSe ci SQ Search 4 Favorites ca Eh A Address E http 192 168 1 10 iGo Meter Data My Settings User Management Module Setup List Users Add User Add Administrator Username Mew Password Retype Password Changeable password ves Access Level Administrator Language Cance Ei l fas Local intranet a User data received will appear 466 Electricity Meter Microsoft Internet Explorer provided by ABE Eile Edit View Favorites Tools Help da Back Ee fay So Search Favorites cas Ea A Meter Data My Settings User Management Module Setup List Users Add User Liser data recieved ET l Es Local intranet P Page 9 of 18 Restart the web browser and a login window will appear Log