User manual Arc Pad 94 Integral Arc Pad 94 Integral EPS

image

Contents

1. Tilt lock Danger of injury Two workers have to handle with the fixture including adjusting the LED module to the desired position The LED module is heavy Five slots in the mounting bracket serve for mounting the fixture on non flammable flat surface Mounting slots Caution Overhead installation requires experience Fixtures may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do not install the device and consult installation with an expert 3 2 Connection to the mains Fixtures must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulation The ArcPad 94 Integral required a 5 cored power data cable The 3 cores serve for the power supply and next 2 shielded cores are intended for DMX connection The power cores are coloured according to the following table Core Plug Terminal Marking INCI RR f eea II TE ArcPad 94 Integral Single colour This device falls under class one and must be grounded The data cores DMX are coloured according to the table ae a The power data cable is connected to a junction box as shown on the picture below Screws Cover Fixture Screws Power data cable Insert flat tip screwdriver Junction box when inserting wire Power data cable Junction box DMX Signal Signal GND Signal ground
2. RDM network 10 12 File Scan Tools Options View joa Ro Get Set Parameters 3 a DMX Network Q A Er f Device UID 52 53 00 2d 00 a3 root device E3 2 T DMX512 Current Personality mode 3 y M Identify Device or y A I DMX Start Address 15 M Device Label Noname Device Reset warm y a Network 1 device 52 53 00 2d 00 a3 Remote LED Display Ready 14 ArcPad 94 Integral Single colour 6 1 Fixture Address Use this menu to set the DMX address of the fixture or set the fixture as a Master Slave dM Ad DMX addressing Select this submenu to set a DMX start address To set a DMX address 1 Use the UP DOWN buttons to find A001 menu Press the ENTER button Use the UP DOWN buttons to select desired start address Press the ENTER button to confirm the choice li cai MA SL Master slave addressing Select this submenu to set the fixture as a master or slave Option d AbL deactivates master slave setting To set a fixture as a master or slave 1 Usethe UP DOWN buttons to find A001 menu Press the ENTER button Use the UP DOWN buttons to select MA SL item Press the ENTER button Use the UP DOWN buttons to select either master MASt or slave SLA Press the ENTER button to confirm the choice A ii oal a Note After switching on the ArcPadXtreme will automatically detect whether DMX 512 d
3. if Pistas tl igus CF9 03 08 Pin Function Wire 1 Red Grey 2 White and Red Pink 3 White Blue 4 Blue Red 5 Blueand Green White 6 Green Brown 7 Temperature Yellow 8 Interconnected with 2 Green Rear view 26 ArcPad 94 Integral Single colour Self adhesive label Chogori O8BMMA SL8001 male Rear view gt Igus CF9 03 08 Pin Function Wire 1 Red Grey 2 White Pink 3 White Blue 4 Blue Red 5 Blue and Green White 6 Green Brown 7 Temperature Yellow 8 Red Green Rear view Standard cables allow max distance betwen LED module and control unit cca 0 7m For longer distance you have to use adapter cables wired 1 1 Chogori female Chogori male O8BFFA SL8001 O8BMMA SL8001 Rear view Rear view BERNE A _ gt gt E E Igus CF9 03 08 Pin Wire Pin Wire 1 Grey 1 Grey 2 Pink 2 Pink 3 Blue 3 Blue 4 Red 4 Red 5 White 5 White 6 Brown 6 Brown i Rear view 7 Yellow 7 Yellow Rear view 8 Green 8 Green ALS Se O O OE O TUVTCP EPP EE ee IE ii i Control unit Power data cable Junction box If the LED module and the base are installed separately on the metal structure LED module and the base are galvanic interconnected the LED module falls under protection class and must be grounded in accordance with all national and local electrical and construction regulations In case that LED module and th
4. The light output is decreased by 25 In Po Init effect positions Use this function to set all effects to the desired positions to which they will move after switching the fixture on if DMX is not being received Note If DMX mode 1 is selected only values set at items MACr macro and dinr dimmer will be accepted dF SE Default Settings The menu item sets all fixture parameters to the default factory values 6 4 Manual mode gap y Pr Use this menu for control the fixture without connected DMX console PrE C Preset effects control Select this menu to call up preset positions of the channel effects Man C Manual effect control Select this menu to control all channels via buttons of the control board To control fixture channels 1 Use the UP DOWN buttons to find Man C menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select desired effect channel List of control channels Stro a shutter strobe function dimr a dimmer F dim a fine dimmer 16 ArcPad 94 Integral Single colour 4 Press the ENTER button and use the UP DOWN buttons to set value press the ENTER button to confirm it 6 5 Test sequences LE CL LLL Use this menu to run demo test sequences without an external controller which will show you some possibilities of using the ArcPad 94 Integral 6 6 Stand alone setting The fixtures on a data link are not connected to the contro
5. If you wish to update only the latest versions of processors check the Incremental Update box Avoid interrupting the process Update status is being displayed in the Info Box window When the update is finished the line with the text The fixture is successfully updated will appear in this window and the fixture will reset with the new software 7 RDM This fixture is ready for RDM operation RDM Remote Device Management is a bi directional communications protocol for use in DMX512 control systems it is the new open standard for DMX512 device configuration and status monitoring The RDM protocol allows data packets to be inserted into a DMX512 data stream without adversely affecting existing non RDM equipment By using a special Start Code and by complying with the timing specifications for DMX512 the RDM protocol allows a console or dedicated RDM controller to send commands to and receive messages from specific moving lights RDM allows explicit commands to be sent to a device and responses to be received from it The list of commands for ArcPad 94 Integral is the following ArcPad 94 Integral Single colour IDENTIFY_DEVICE DEVICE_MODEL_DESCRIPTION MANUFACTURER_LABEL DEVICE_LABEL SENSOR_DEFINITION SENSOR_VALUE DISPLAY_LEVEL DEVICE_RESET DMX_PERSONALITY DMX_PERSONALITY_DESCRIPTION STATUS MESSAGES STATUS _ID DESCRIPTION DEVICE_HOURS 8 Error and information messages t M Er Temperature measuring
6. Power L Live N Neutral PE Earth DMX IN ArcPad 94 Integral Single colour 3 3 Installation of the barn doors top half top hats You can install barn doors or top hats to better define illuminated surface Before installing the equipment disconnect the fixture from the mains 1 Fit the barn doors module 1 or top half top hat 2 on the LED module 4 and fasten it by means of the 12 screws 3 as shown on the picture below Half top head Never close the barn doors during fixture operation 3 4 Setting and control For setting DMX address selecting DMX mode and for another settings you need either Robe Universal Interface or RDM Communicator Please see the Robe Universal Interface or RDM Communicator user manuals to get more information about this products The way how to connect these interfaces to the DMX data link is figured below NOTE never connect the RDM communicator and the The Robe Universal Interface to the fixture at the same time 1 Robe Universal Interface Control PC o SN K RDM A Robe Universal Interface Junction box DMX console Power cable DMX data cable DMX512 Power data cable ArcPad 94 Integral Single colour 2 RDM Communicator Note DMX controller has to be disconnected from the fixture when the RDM communicator is operated RDM Communicator Power data cable Junction box DMX data cable DMX512 RDM protocol 3 5 DMX 512 connection To
7. a serial port of PC Robe Universal Interface if you want to use an USB port of PC Note1 Software update should execute a qualified person If you lack qualification do not attempt the update yourself and ask for help your ROBE distributor Note 2 DMX address programs 1 3 and all items in the menu PErS will be set to their default values To update software in the fixture I Installation of the DMX Software Uploader 1 DMX Software Uploader program is available from theAnolis web site at WWW anolis cz 2 Make a new directory e g Anolis Uploader on your hard disk and download the software into it 3 Unpack the program from the archive II Fixture software updating If you use the RDM Communicator 1 Disconnect the fixture from other fixtures in a DMX link 2 Connect the RDM communicator to the fixture and switch this fixture to the update mode 1 Use the UP DOWN buttons to find SPEC menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select uPd item 18 4 5 6 ArcPad 94 Integral Single colour 1D 5253 0024000A Remote LED Display os IO VIO X Press the ENTER button Use the UP DOWN buttons to select yES option Press the ENTER button Note If you do not want to continue in software update you have to switch off and on the fixture to escape from this menu 3 Disconnect the RDM communicator from the fixture 4 Connect serial port of your PC with a DMX input of
8. error The message informs you that the LED module temperature sensor is defective MA Er Master error The fixture is set as a master and DMX console is connected to the fixture 21 ArcPad 94 Integral Single colour 9 Technical specifications Power supply e Electronic auto ranging e Input voltage 100 250V AC 50 60 Hz e Power consumption Power Max power consumption Typical power consumption Ambient mode All LED channels at full 2 LED Channels at full Temperature Full mode 290W 300VA 155W 25 C Eco mode 150W 160VA SOW e Fuse F12A 250V Optic amp Effects e Light source 94 ProLight Opto 3Watt Proeon LEDs e Available optical systems na 10 23 44 14 x26 e Adjustable strobe sequences eLumen maintenance Channels Power L70 One LED Full mode 95 000 Two LED Full mode 90 000 Three LED Full mode 84 000 All LED Full mode 77 000 L79 70 maintenance of initial lumen output in hours Electronics e Control USITT DMX 512 RDM support e Control options DMX RDM e Operations modes DMX Master Slave e DMX protocol modes 2 1 3 control channels e Manual control of all effects via RDM communicator e 3 user editable programs each up to 68 steps Strobe e Strobe effect with variable speed max 20 flashes per second e Pre programmed random strobe pulse effects Dimmer e Smooth 16 bit dimming from 0 100 Connection e Power data cable e junction box Rigging e Via mounting bra
9. the area below the installation place is blocked when rigging derigging or servicing the fixture Do not block the front objective LEDs with any object when the fixture is under operation The fixture becomes very hot during operation Allow the fixture to cool approximately 40 minutes prior to manipulate with it Operate the fixture only after having familiarized with its functions Do not permit operation by persons not qualified for operating the fixture Most damages are the result of unprofessional operation Do not attempt to dismantle or modify the unit Please consider that unauthorized modifications on the fixture are forbidden due to safety reasons Please use the original packaging if the fixture is to be transported If this device will be operated in any way different to the one described in this manual the product may suffer damages and the guarantee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock etc 2 Fixture exterior view S NN A y 1 LED module 5 Power data cable 2 Tilt lock for LED module 3 Mounting bracket 4 Control unit ArcPad 94 Integral Single colour 3 Installation 3 1 Mounting the fixture Ensure that the structure truss wall to which you are attaching the fixture is secure The ArcPad 94 Integral can be arranged in any position orientation The LED module can be tilt to desired position by means of the Allen key 14
10. ANOLIS ArcPad 94 Integral Single colour USER MANUAL ArcPad 94 Integral Single colour Table of contents LS ANS EMU CIO IS SE O o E at notat ta e Da dl ai a tetas 3 2 FIXTEC EXE IO VIEW e sac atesta A ti die 4 A dc ta cint natala nl ad a d za ab stat ata ul roata alu ta ta bl il d 5 a PP A 5 32 Connection to the Maldita 5 3 3 Installation of the barn doors top half top Nat ii 7 SOUS AI CONE AMA A a dan e a titi encased au a ali te aia ae 7 29 DMX 5 12 COMECON amiaz sa bien oaia cota a oii mara at Di aaa ll aa se ten 8 3 6 Master slave ds 8 SD SLAG GIONS Operations ero ell iio ato delas 8 4 ArcPad 94 Integral Single colour DMX Protocol cccccccccssssseccceceesseccccceeseeceeeuecceeseueecceseeueeseceseseunseceeesaggnsss 10 De CORUL OL IE MU Va Dato ua dale ad cerea 11 Our IX CURE MENU AS e Rd does eat etes dedans tie bee 13 O E RUT ARS ne apa Bod dana oa 15 OS FICS ROI a CIO astea ie rn 15 5 3 Persona Veera sai 350 ae PA Sl alai an ali al ala 16 Manta Mode ata POR SR A RR SIN A ENE RT tes ov ROI A NC E INN sebum NI RI ASI a E VIN 16 Gir leS t CUENCO SE AR O RR IESIRI NERO RR IRAN PRR IE Cd a nanan acid 17 6 6 Stand lon SLUNG see ta sa dac sasa A AI alla et i a a a n 17 6 7 Special TUNCUO MS zac cai act door n ai at ta al aaa inoata asi tal na ni 18 TaD RRE E e ER 20 8 Eror anda MNtorfmatonimMess ares oe 21 Oc Technical SPECIFICATIONS id 22 10 Cleaning and mantencion 25 TLADENOIX e as 26 11 1 Arcra
11. DMX controller before master slave operating otherwise data collisions can occur and the fixtures will not work properly ArcPad 94 Integral Single colour 4 ArcPad 94 Integral Single colour DMX protocol Version 1 0 Mode Channel a Value Type of control MIN 1 Strobe 0 31 Shutter closed step 32 63 Shutter open step 64 95 Strobe effect from slow to fast proportional 96 127 Shutter open step 128 143 Opening pulses in sequences slow gt fast proportional 144 159 Closing pulses in sequences fast gt slow proportional 160 191 Shutter open step 192 223 Random strobe effects from slow to fast proportional 224 255 Shutter open step 1 2 Dimmer 0 255 Dimmer intensity from 0 to 100 proportional Dimmer fine 3 0 255 Fine dimmer intensity from low to high proportional 10 ArcPad 94 Integral Single colour 5 Control menu map Default settings Bold y jon fous CECI e A II E 0 EI E LE m ee ArcPad 94 Integral Single colour Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 PO O E ee dFSE CES II E es pe hp IN RC CTN IO EE II IO ES IES 12 ArcPad 94 Integral Single colour Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 6 Fixture menu RDM communicator Connect the RDM communicator to the fixture and from the menu Control select the Remote LED display item The fixture s control display with the f
12. TER button The selected program runs in a loop Edit Editing a program The fixture offers 3 freely editable programs EPG 1 EPG 3 each up to 68 steps Every program step includes a fade time the time taken by the step s channel status to reach the desired level and a step time the total time occupied by the step in the program E g If F tim 5 second and S tim 20 second effects will go to the desired position during 5 seconds and after that they will stay in this position for 15 seconds before going to the next prog step 1 1 Use the UP DOWN buttons to find St AL menu and press the ENTER button 2 Use the UP DOWN buttons to select Edit menu and press the ENTER button 3 Use the UP DOWN buttons to select a program you want to edit PrG 1 PrG 3 and press ENTER button 4 Use the UP DOWN buttons to select a desired program step St 01 St 68 and press ENTER button 5 Use the UP DOWN buttons to select a channel you want to edit and press the ENTER button List of editable items P End a total number of the program steps value 1 68 This value should be set before start Programming e g if you want to create program with 10 steps set P End 10 Stro a shutter strobe function 17 ArcPad 94 Integral Single colour dimr a dimmer F dim a fine dimmer F tim a fade time 0 25 5 seconds S tim step time value 0 25 5 seconds COPY thi
13. ata is received or not If there is no data received at the DMX input the display will start to flash A001 with actually set address 6 2 Fixture information Use this menu to read useful information about the fixture status To display desired information 1 Use the UP DOWN buttons to find the InFo menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select the required menu item 4 Press the ENTER button to confirm the choice Po ti Power On Time Use the menu item to read the number of operation hours for each LEDs operating mode totL the function shows the total number of the operation hours since the ArcPad 94 Integral has been fabricated rESEt the function shows the number of the operation hours that the ArcPad 94 Integral has been powered on since the counter was last reset In order to reset this counter to O you have to press and hold the UP and DOWN buttons and at the same time press the ENTER button DM In DMX values Select this function to read DMX values of each channel received by the fixture tEMP Fixture Temperatures Select this menu to read the temperatures of the fixture Cur t the current temperature of the fixture inside Hi tE the menu item shows the max temperatures of the fixture inside since the ArcPad 94 Integral has been fabricated rSEt the menu item shows the maximum temperatures of the fixture inside since the counter was last reset In order to reset this c
14. build a DMX chain 1 Connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain 2 Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture 3 Always connect the DMX output with the input of the next fixture until all fixtures are connected Do not overload the link Max 32 fixtures may be connected on a DMX link Caution Terminate the output of the last fixture with a 120 Ohm resistor wired betwen data and data in order to ensure the proper transmission on the data link 3 6 Master slave connection To build a master slave chain Connect the DMX output of the master fixture in the data chain with the DMX input of the first slave Always connect output with the input of the next slave until all slaves are connected up to 32 fixtures Caution It is necessary to terminate the input of the master fixture and the output of the last slave with a 120 Ohm resistor in order to ensure the proper transmission on the data link 3 7 Stand alone operation The fixtures on a data link are not connected to the controller but can execute pre set programs which can be different for every fixture To set the program to be played see the Stand alone setting menu St AL Stand alone operation can be applied to the single fixture or to multiple fixtures operating synchronously Synchronous operation of multiple fixtures requires that they must be connected o
15. cket Temperatures 22 ArcPad 94 Integral Single colour e Maximum ambient temperature 40 C e Maximum housing temperature 85 C Dimensions mm ArcPad 94 Integral mil a Cf AAA AAA A MERA AAA AA AAA lc E OLD EEE CL IE EEE EE CE bhi IE BRA AA E BANAL es II HAN se AAA 147 138 3 br bh Weight e 39 kg 23 ArcPad 94 Integral Single colour Protection factor e IP 67 fixture IP 66 junction box Included items e 1 x ArcPad 94 Integral e 1 x Junction box No 99012672 e 1 x User manual e 1 x Gasket of cable grommet M20 PF P N 1305 1388 Optional accessories e Barn doors in silver colour No 1098 0097 e Top hat in silver colour No 10980098 e Half top hat in silver colour No 10980099 Note By reason of the fast moving development of LED technology newer products may have better light parameters than previous products 24 ArcPad 94 Integral Single colour 10 Cleaning and maintenance DANGER Disconnect from the mains before starting any cleaning or maintenance work Rinse off loose dirt with a garden hose or low pressure water spray Wash the housing with a soft brush or sponge and a mild non abrasive washing detergent Rinse it There are no serviceable parts inside the device Maintenance and service operations are only to be carried out by a qualified person Should you need any spare parts please use genuine parts If the p
16. d 94 Integra EPS ai ias 26 ArcPad 94 Integral Single colour FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR ArcPad 94 Integral Save it for future reference This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the device Please consider that damages caused by manual modifications to the device are not subject to warranty 1 Safety instructions DANGEROUS VOLTAGE CONSTITUTING A RISK OF ELECTRIC SHOCK IS PRESENT WITHIN THIS UNIT Make sure that the available voltage is not higher than stated on the rear panel of the fixture This fixture should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supplied consult your authorized distributor or local power company Always disconnect the fixture from AC power before cleaning removing or installing the fuses or any part Do not overload wall outlets and extension cords as this can result in fire or electric shock Make sure that the power data cord is never crimped or damaged by sharp edges Check the fixture and the power data c
17. e base are installed separately on the insulant e g wall LED module and the base are not galvanic interconnected the LED module falls under protection class 3 and does not need to be grounded Cables e LED module connection cable Igus CF9 03 08 connectors 2x Chogori O8BFFA SL8001 2x Chogori O8BMM SL8001 NOTE max length betwen LED module and control unit 20m 27 ArcPad 94 Integral Single colour Dimensions mm Weight LED module with mounting bracket 24 kg Control unit 9 kg Specifications are subject to change without notice July 21 2014 28
18. ller but can execute pre set programs which can be different for every fixture Stand alone operation can be applied to the single fixture or to multiple fixtures operating synchronously Synchronous operation of multiple fixtures requires that they must be connected on a data link and one of them is set as a master MASt and the rest as the slaves SLA Up to 32 fixtures can be connected in a master slave chain Only one fixture can be set as the master Note Disconnect the fixtures from the DMX controller before master slave operating otherwise data collisions can occur and the fixtures will not work properly See the chapters Stand alone operation and Master slave connection Auto Automatic playback This function allows you to select the program which will be played after switching the fixture on Selected program will be played continuously in a loop 1 Use the UP DOWN buttons to find St AL menu Press the ENTER button Use the UP DOWN buttons to select Auto item Press the ENTER button Use the UP DOWN buttons to select desired program Press the ENTER button to confirm the choice a E PLAY Playing program By enter to this menu a complete overview of all programs is offered from which the program to be run can be selected 1 Use the UP DOWN buttons to find St AL menu 2 Press the ENTER button 3 Use the UP DOWN buttons to select desired program 4 Press the EN
19. n a data link and one of them is set as a master master mode and the rest as the slaves slave mode To set the fixture as the master or slave see the Fixture Address menu A001 Only one fixture can be set as the master The master fixture starts simultaneous program start in the other slave fixtures All fixtures have a definite synchronized starting point when playing back their programs The number of running program is the same in all slaves and depends on the master s choice menu St AL Every fixture runs its program repeatedly starting the program step No 1 when requested by the master Example If the slave fixture has a shorter program length it will continuously repeat its program until the master fixture finishes its own program and restarts its program running slave 1 prog step 3 will not be finished 8 ArcPad 94 Integral Single colour If the slave fixture has a longer program length it will restart at prog step 1 before it completes all its prog stintegral slave 2 prog step 5 will not be played see the picture bellow Prog step 1 Master Prog step Prog step 2 Prog step 3 Prog step 4 Prog step 5 Program length Continous repeating Prog step Slave 1 Prog step Prog step 2 Prog step 3 Prog step Prog step 2 Prog step 31 Program length Slave 2 Prog step 1 Prog step 2 Prog step 3 Prog step 4 Prog step 5 Program length Time Note Disconnect the fixtures from the
20. ord from time to time Do not install the unit near naked flames During the operation the housing becomes hot up to 85 C Refer servicing to qualified service personnel This fixture falls under protection class Therefore this fixture has to be connected to a mains socket outlet with a protective earthing connection Do not connect this fixture to a dimmer pack LED light emission Risk of eye injury Do not look straight at the fixture s LEDs during operation The intense light beam may damage your eyes Keep compustible materials at least 40 cm away from the fixture If the fixture has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature Do not shake the fixture Avoid brute force when installing or operating the fixture The fixture was designed for indoor use and it is intended for professional application only It is not for household use ArcPad 94 Integral Single colour When choosing the installation spot please make sure that the fixture is not exposed to extreme heat or dust Avoid using the unit in locations subject to possible impacts The fixture body never must be covered with cloth or other materials Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fastened Make sure that
21. ounter to O you have to press and hold the UP and DOWN buttons and at the same time press the ENTER button 15 ArcPad 94 Integral Single colour Note The ambient temperature should not exceed 40 C Measuring points LEdS the temperature of the LEDs module boAr the temperature on the PCB in control unit The temperatures can be displayed in either C or F units see option tEM U in the menu Pers VErS Software Versions Select this function to read the software versions of the fixture processors IC1 the processor controls LEDs module IC2 EEprom 6 3 Personality Use this menu to modify the ArcPad 94 Integral operating behaviour DM Pr DMX preset Select this menu item to set a desired DMX mode Please refer to the chapter DMX protocol for detail description of each DMX mode DiSP Display adjusting This function allows you to change the display settings d On this function allows you to keep the display on or to turn off automatically 2 minutes after last pressing any button on the control panel d Int select this function to adjust the display intensity 20 min 100 max turn select this function to turn the display by 180 tEM U Temperature Unit Use this menu in order to display the fixture temperatures in desired units C or F LoAd Load of LEDs The menu allows to choose 2 different operating modes for fixture FuLL Maximum light output ECO
22. our control buttons will appear on the screen of the RDM communicator 10 5253 0024000A Remote LED Display PREV NEXT ENTER ESCAPE POWER ON OFF The control buttons have the following functions A ESCAPE button leaves menu without saving changes lt l ENTER button enters menu confirms adjusted values and leaves menu A UP and Y DOWN buttons move between menu items on the same level sets values A Robe Universal Interface Run the RDM network and click with the right button of the mouse on the fixture and select the Remote LED display option from the menu list as shown below 13 ArcPad 94 Integral Single colour 7 RDM network 10 12 Eile Scan Tools Options View lea ES EP A Get Set Parameters Ga a B DMX Network QQ E fe fe fe Device UID 52 53 00 2d 00 a3 root device amp DIMS12 Current Personality mode 3 y M Identify Device off y ES DMX Start Address 15 M Device Label Noname Device Reset warm y Lamp State Lamp On Mode Ay T Display Invert for y Display Level 255 Pan Invert Tilt Invert E i im Network 1 device Single Device Patch DMX Addresses Collect Parameters View Sensor values Remote LED Display Set Parameter Ready The Remote LED Display window will appear Now you can fullly control the fixture using the UP Down Enter Escape and Reset buttons
23. ower supply cable of this device will be damaged cable firmly connected with the device it has to be replaced by authorized distributors only in order to avoid hazards 25 ArcPad 94 Integral Single colour 11 Apendix 11 1 ArcPad 94 Integral EPS Besides the ArcPad 94 integral exists variant with separated LED module and control unit which is named the ArcPad 94Integral EPS Its differences compared to the ArcPad 94 integral are described below Control ans setting is the same as at the compact version Fixture exterior view Correct interconnection of LED module and control unit has to be kept The Chogori connectors are marked by self adhesive labels and the following order of cables should be observed LED1 LED1 LED2 LED2 1 LED module 5 Control unit 2 Tilt lock for LED module 6 Power data cable 3 Mounting bracket 7 Junction box 4 LED module connection cables connectors Connection between LED module and control unit Two pairs of the lgus CF9 03 08 cables serve for interconnection of the LED module and the control unit The ChogoriBuccaneer connectors are marked by self adhesive labels LED1 LED2 next to the connectors and the following order of cable connections has to be kept to ensure correct operation of the fixture LED1 LED1 LED2 LED2 Wiring of the Chogori connectors See ee eee a A o a i ma ENT mi d Self adhesivelabel Chogori O8BFFA SL8001 female Rear view gt gt
24. s item duplicates the current prog step to the next prog step The item P End is increased automatically 6 Use the UP DOWN buttons to set a DMX value of the channel and then press the ENTER button Use the UP DOWN buttons to select next channel and press the ENTER button 8 After having set all channels in the current program step press the MODE button to go by one menu level back and select another program step a 6 7 Special functions rdML Code This menu item shows the first part of the RDM identification code rdMH Code This menu item shows the second part of the RDM identification code Adi Effect Adjustment The menu allows calibration of each LEDs array dMH DMX Values The menu item enables to control all LEDs before calibrating each LEDs array CAL U Calibrating unit The menu serves for fine current calibration of LEDs during fixture burn in at a factory Each colour can be calibrated separately Users should not change the setting Hold Hold DMX If the function is on the last received DMX values are held in case that DMX data receiving was interrupted e g disconnected DMX controller uPd M Updating mode The menu item allows you to update software in the fixture via either serial or USB port of PC The following are required in order to update software PC running Windows 95 98 2000 XP or Linux DMX Software Uploader Flash cable RS232 DMX No 13050624 if you want to use
25. the fixture if you using the flash cable RS232 DMX If you use the Robe Universal Interface 1 Disconnect the fixture from other fixtures in a DMX link 2 Connect the Robe Universal Interface to the fixture and switch this fixture to the update mode 1 2 3 4 5 6 7 Run the RDM Network and select menu item Remote LED Display Use the UP DOWN buttons to find SPEC menu Press the ENTER button Use the UP DOWN buttons to select uPd item Remote LED Displa TOR Press the ENTER button Use the UP DOWN buttons to select yES option Press the ENTER button Note If you do not want to continue in software update you have to switch off and on the fixture to escape from this menu 8 After switching the fixture to the update mode cancel the RDM Network program Run the Software Uploader program Select desired COM and then click on the Connect button Note we recommend to cancel all running programs before starting the Software Uploader 19 ArcPad 94 Integral Single colour ColorSpot 700EAT Software Uploader v3 0 Select COM if the serial port is used Select Robe Universal Interface if the USB port is used If the connection is OK click on the Start Uploading button to start uploading It will take several minutes to perform software update If the option Incremental Update is not checked all processors will be updated including processors with the same software version

Download Pdf Manuals

image

Related Search

Related Contents

USER MANUAL - Best Kiteboarding  Manual de Instrucciones testo 523 Analizador de refrigeración  Konica Minolta MM-A208 Digital Camera User Manual  アーマープラスSG テッカマンレイピア 取扱説明書 540.5 KB  CGS - V4.3.0 Installation Manual (Issue 4/F)  TRS104[05.08]    IBM PCI Hot Plug Services User Guide - ps  Toshiba Satellite S875-S7370  ENG - DIESSE Diagnostica Senese  