Home
SOLAR 200 SOLAR 300N I-V 400 SOLAR I-V - EURO
Contents
1. PC for subsequent analyses The measured l V characteristic is not affected by the resistance of the measurement cables as the measurement Is carried out with the 4 terminal measuring method SOLAR V also manages a database of photovoltaic modules which can be updated at any time The measured values correctly reported at standard test conditions are immediately compared with the values declared by the manufacturer to give the OK NO result of the test The operator must not do any calculation the instrument carries out the comparison rapidly and automatically FUNCTIONS GENERAL CHARACTERISTICS LCD custom 128x128pxl backlit 6x1 5V alkaline bat type AA LROO after 5 minutes in stand by 1 5 hours IP 55 5 days IP 15min gt 200 curves Photovoltaic installation testing Display Measurement of DC AC TRMS voltage and current Measurement of DC AC powers on single phase systems Measurement of solar irradiation W m with reference cell Measurement of environmental and module temperature by means of external probe Synchronization with remote unit SOLAR 02 Display of real time irradiation and temperature Use of PDC compensation ratios according to environmental and module temperature Recording of parameters with programmable IP bs 60min l V characteristic measurement Meas of output voltage from module string up to 1000V DC Power supply Auto power off PV testing duration Curves which can be saved PC i
2. PHASE PHOTOVOLTAIC SYSTEMS SOLAR200 is an innovative instrument designed for carrying out electrical safety verifications on photovoltaic systems in compliance with the relevant safety requirements The instrument is very easy to use and has a wide range of functions which can be selected by means of the simple multi language menu Measurements can be started both by pressing the button located on the instrument body and by pressing the button located on the remote aise optional accessory PR400 which makes c ut more measurements in sequence ver line which can be selected D any function is a vali instrument to the s with an internal me connection an be analyzed with the d ested SOLAR200 is provided id an optical USB interface for PC nsferring measured data which can edicated software FUNCTIONS Continuity of protective conductors with 200mA Insulation with test voltages of 50 100 250 500 1000VDC Tripping time of RCDs type A AC general and selective with nominal current up to 5OOmA Tripping current of RCDs type A AC general and selective with nominal current up to 5OOmA Impedance of Loop Line P N P P P PE also with high resolution O lm with optional accessory IMP5 and lpsc calculation Total earth resistance with no RCD tripping Contact voltage Phase sequence Activation of measurements with optional remote probe PRAOO Help on line on the display saving of results Optical USB interf
3. 14 MULTIFUNCTION INSTRUMENT FOR TESTING AND VERYFYING SINGLE PHASE PHOTOVOLTAIC INSTALLATIONS SOLAR l V has been designed to meet any requirement of photovoltaic installation specialists Further to providing the possibility of measuring and recording the efficiency of single string and single phase photovoltaic systems SOLAR l V also measures the l V characteristic both of a single module and of module strings Thanks to SOLAR I V the operator can test the photovoltaic system and should it give a negative result immediately identify the problems of the system in order to promptly solve them SOLAR l V is provided with the remote unit SOLAR 02 which permits the remote measuring of irradiation and temperature with preliminary automatic synchronization between main unit and remote unit SOLAR O2 is positioned next to the photovoltaic modules and it is connected to the probes for measuring environmental parameters The synchronization between the two units guarantees the necessary contemporaneity of measurements In the case of PV efficiency recordings this grants the right efficiency calculation For l V curve measurements the synchronization permits to extrapolate the l V curve at SIC without using long extension cords cable SOLAR l V allows carrying out efficiency recordings over time with programmable integration period from 5 seconds to 60 minutes Each value is automatically saved in the internal memory and can be downloaded onto the
4. INSTRUMENTS FOR VERIFICATION ANALYSIS AND TESTING OF PEOTOVOLTAIC SYSTEMS NAAN 39 Nen NA w S NN ss S ON Nr Y a NN CRT NO ES WN x k CX MN Xx x 4 LI 4 SOLAR300N 3 PHASE PV SYSTEM ANALYZER N n 9196 COSS Ne NS SAAS I V400 l V CURVE TRACER OK NO _ Why to use a reference cell Photovollaic modules partially convert solar radiation into electric power The efficiency of photovoltaic modules is strongly affected by several factors such as operating temperature of modules manufacturing technology of modules angles at which solar radiation hits the modules surface spectral composition of solar radiation etc It is obvious that to properly evaluate the performance of the photovoltaic modules under test it is necessary to measure the solar radiation which they are subject lo by means of a transducer with features similar to the modules ones Using a sensor with a different manufacturing technology could lead to inconsistent measurements of solar radiation and consequently to incorrect measurements of the modules under test For this reason HT photovollaic testers are provided with the reference cell HT304 as standard accessory HT304 is featured as follows it is provided with a built in temperature sensor allowing compensation of the measured values itis provided with two sensors made of monocryst
5. Mechanical i inclinometer M304 Remote unit for the detection of the SOLAR O2 for recording incidence angle of solar irradiation irradiation and temperature connected to RF SOLAR 02 a wa SOLAR I V SOLAR 02 Top bd Made inWtaly SOLAR 200 SOLAR 3OON l V 400 SOLAR I V HT ITALIA SRL Via della Boaria 40 48018 Faenza Ra Phone 39 0546 621002 Fax 39 0546 621144 E mail export htitalia it www htitalia com FAENZA ITALY STAMPA LABANTI NANNI BO 12 2010 en a lt e ps a Lu o 5 De Nederlandse vestiging van EURO INDEX beschikt over een bijzonder modern service en kalibratie laboratorium Hier worden de meetinstrumenten uit het assortiment preventief onderhouden gerepareerd gekalibreerd en indien nodig gejusteerd Het service en kalibratielaboratorium van EURO INDEX is verdeeld in verschillende disciplines gebaseerd op het soort meetinstrument en de gemeten grootheden Druk Elektrische grootheden Gasanalyse Gasdetectie Temperatuur inclusief infrarood Luchtsnelheid en luchthoeveelheid temperatuurmeting en thermografie Een kalibratiecertificaat vermeldt hoeveel een meetinstrument afwijkt ten opzichte van onze naar inter nationale standaarden herleidbare kalibratiemiddelen Bij de meetresultaten op het certificaat wordt tevens vermeld of het meetinstrument voldoet aan de specificaties die door de fabrikant zijn opgegeve
6. Power supply by rechargeable battery and by means of external power supplier Use of remote unit Efficiency measurement recording of single string systems Efficiency measurement recording of multi string systems Efficiency measurement recording of single phase systems Efficiency measurement recording of three phase systems Irradiation measurement with reference solar cell Temperature measurement of modules and environment Detection of curve of modules and strings Internal database of PV modules Measurement of modules and strings data Voc Vmpp Impp Isc Pmax FF Domax Auto power off Memory capacity Extension of internal memory with external Compact Flash USB port for connection of external memory sticks PC interface with software for Windows Context sensitive help on the display Saving of recordings and instant values Dimensions LxWxH mm Weight batteries included Kg Safety in compliance with IEC EN61010 1 SOLAR200 SOLAR3OON l V 400 SOLAR I V 500 locations 235x165x75 12 e 1s 60m 25 e optional accessory 1 month Pl 15min 251 par 235x165x75 1 e 1000V 10A z gt 200 curves 235x165x75 12 e 5s 60m optional accessory optional accessory e 1000V 10A gt 200 curves 5 days Pl 15min 235x165x75 IE SOLAR200 M MULTIFUNCTION INSTRUMENT FOR SAFETY VERIFICATION OF SINGLE PHASE AND THREE
7. ace for PC connection SOLAR200 GENERAL CHARACTERISTICS LCD custom backlit 6x1 5V alkaline bat type AA IEC LROO 500 locations Display Power supply Internal memory PC interface optoisolated optical connector Safety IEC EN61010 1 Insulation double insulation Pollution degree 2 CAT III 240V to earth CAT II 415V between inputs CEI 64 8 IEC EN61557 1 MOON STER approx 1 25kg Measurement category Reference standards Dimensions Weight bat included ACCESSORIES SUPPLIED Code Series accessories Cable with three pin shuko plug C2033 Kit of 3 cables 3 alligator clips 1 probe UNIVERSALKIT Transport bag BORSA 5 User manual Calibration certificate ISO9000 Optional accessories Windows software for PC optical USB cable TOPVIEW2006 Remote probe for test activation PR400 Accessory for measuring loop impedance with high resolution IMPS Kit of belts for slinging the instrument over one s shoulder SP 0400 IMP57 Accessory for measuring PR400 loop impedance with high Remote probe resolution SOLAR300N Z MULTIFUNCTION INSTRUMENT FOR TESTING SINGLE PHASE AND THREE PHASE PHOTOVOLTAIC SYSTEMS AND ANALYZING MAINS QUALITY IN COMPLIANCE WITH STANDARD EN50160 SOLAR300N allows carrying out all tests required for the verification of the efficiency of single phase and three phase photovoltaic systems Testing photovoltaic systems requires contemporarily measuring en
8. alline and polycrystalline silicon respectively to better suit the manufacturing technology of the modules to be tested it better reflects the close correlation of the modules under test with the solar radiation incidence angle as well as with its spectrum composition it grants a quick response the same as the photovoltaic modules This last feature is crucial in case of measurements taken under conditions of variable cloudiness SOLAR 200 The photovoltaic installation is an elec trical system under all respects and its Safety must be certified in compliance with the regulations in force As the photovoltaic modules are instal led outdoors and directly irradiated by the sun they are subject to extreme environmental conditions such as hot weather in summer frost in winter rain and hail etc All this makes safety testing even more necessary Safety is not to be neglected in the as sembly and maintenance of a photovol taic installation The regulations in force state that quality marks and certification on components are not enough and that an instrumental measurement is required TESTING WITH SOLAR 300N AND SOLAR I V To apply for special tariffs the electricity user needs to provide a test certifica te along with sundry documents his document certifies that the installation ensures a minimum efficiency level It is therefore necessary to employ mea suring instruments bringing about si gnifica
9. ata saving Pollution degree 2 whether or not the string or the module being tested respects e ue ecalling results on the display Measurement category CAT II 1000V CAT 300V to the characteristics declared by the manufacturer Optical USB port for PC connection earth Max 1000V between In some PV installations such as roof top installations it may be Help on line on the display inputs difficult to access the module output cables An access to the Ed SEE nn cables at the combiner box or at the inverter s inputs may be the only chance In this case the measurement of I V characteristics Weight batteries included 1 2kg can be achieved by measuring the environmental parameters irradiation and temperature through the remote optional unit SOLAR 02 The remote unit is positioned next to the photovoltaic modules and it is connected to the probes for measuring environmental parameters The synchronization between the two units guarantees the necessary contemporaneity of I measurements making possible the extrapolation of the I V measurements In its internal memory 400 manages a database of photovoltaic modules which can be on the instrument Together with the measurement of the I V characteristic and the extrapolation of the characteristic at standard test conditions l V 400 compares the obtained values ACCESSORIES SUPPLIED lype Sharp 15 655 Series accessories Kit of 4 cables
10. dule temperature automatic or by means of external probe Auto power off after 5 minutes in stand by l V 400 is the ideal solution for the ordinary and scheduled Meas of D f maintenance of photovoltaic systems With l V 400 searching i Hii Soe LU ee eu Internal memory 296kBytes for possible failures and problems in systems is extremely rapid Numerical and graphical display of l V characteristic Curves which can be 200 efficient and intuitive l V 400 carries out the field measurement Measurement of the resistance of photovoltaic module series saved of the l V characteristic and of the main characteristic parameters At PC interface optoisolated optical USB port betreten ahi ande dote ne amen Mechanical inclinometer for the detection of the incidence le of solar irradiati z measures together with the I V characteristic of the device A ar M sel IBCHENO LONG d being tested also the values of its temperature and incident sender reste ans CTO Measuring accessory safety IEC EN61010 031 IEC EN10 032 irradiation The acquired data are then processed to extrapolate Evaluation of testing result OK NO IEC EN 60891 the l V characteristic at standard test conditions STC in order M f ph to proceed with the comparison with the nominal data declared H a e i Insulation double insulation by the modules manufacturer thus immediately determining Internal memory for d
11. en voorzien van een RvA kalibratiecertificaat De metingen worden uitgevoerd met standaarden waarvan de herleidbaarheid naar inter nationale stan daarden ten overstaan van de Raad voor Accreditatie is aangetoond In het Multilateral Agreement zijn de meeste Europese landen overeengekomen elkaars accreditaties te accepteren Hierdoor is een RvA kalibratiecertificaat internationaal geaccepteerd Bovendien wordt op een RvA kalibratiecertificaat de meetonzekerheid van de gerapporteerde meetresultaten vermeld EURO INDEX biedt een assortiment meetinstrumenten te huur aan Na deskundig advies van onze pro ductspecialisten wordt bepaald welk instrument u nodig heeft voor uw specifieke werkzaamheden De instrumenten worden compleet met accessoires geleverd inclusief herleidbaar kalibratiecertificaat Wijzigingen voorbehouden EURO INDEX VL 13001 ge 1 EN RvA K105 kantan Som erkend leerbedrijf WWW rva nl
12. ery Graphical touch screen display Testing result on the display of SOLAR300N Testing result on TopView software Touch screen pen PT400 Widows software USB cable TOPVIEW2007 Rigid transport suitcase VA400 Professional transport suitcase User manual on CD ROM LOADS AC INVERTER pc Rapid user guide 1 A f Calibration certificate ISO9000 m Ru 5 Opzional accessories ues vs Rigid clamp AC 1 100 1000A 1V diameter 54mm HT96U Rigid clamp AC 10 100 1000A 1V diameter 54mm ile Acquiring Rigid clamp DC AC 1000A 1V diameter 50mm HT98U SOLAR300N Receiving Rigid clamp AC 200 2000A 1V diameter 0mm HP30C2 CONNECTION SCHEME Rigid clamp AC3000A 1V diameter 70mm HP30C3 THREE PHASE Flexible clamp AC 3000A diameter 174mm ha UR s e Flexible clamp AC 3000A diameter 274mm RF LEXSS SOLAR300N SOLAR 02 Interface 3x1 5A 1V for connection of external CTs HT903 Kit of belts for slinging the instrument over one s shoulder SP 0400 Connector with magnetic tip 606 IECN only for using the instrument as mains analyzer I V 400 JA FUNCTIONS GENERAL CHARACTERISTICS MULTIFUNCTION INSTRUMENT FOR 9 ves d ee Mod id T up to UE uL VERIFICATION OF I VCHARACTERISTICOF Meas of output current from module string up to Power supply 6x1 5V alkaline batteries type PHOTOVOLTAIC STRINGS AND MODULES e Measurement of solar irradiation W m with reference cell AA ROG e Measurement of mo
13. face Safety Insulation Pollution degree Measurement category Unbalance Qualit di rete Flicker Electric power quality Dimensions Weight with battery TFT 65536 colours 320x240pxl high contrast touch screen 1x3 V rechargeable Li ION battery with external power supply dura tion 6h auto power off after 5 min in stand by 15Mbyte duration approximatel 3 months IP 15min and 25 parameters selected compact flash CF card 20 IEC EN61010 1 double insulation 2 CAT IV 600V to earth CAT 1000V between inputs IEC EN61000 4 7 IEC EN50160 IEC EN61000 4 15 IEC EN61000 4 30 Classe B ZS Meren approx 1kg 13 05 2008 14 24 28 ACCESSORIES SUPPLIED ILC Series accessories ed ade Vdc 316 8 V Vac 233 1 V t m Remote unit to record irradiation and temperature SOLAR 02 4 Ide 7 170A lac ke AU Er Ga J Pdc 2 27 kW Pac 2 mm m Kit of 5 cables alligator clips for vollage measurement KIT800 pf 100i oe Rigid clamp 5 100AC 1V diameter 20mm 3 UTAGGE nde 0 91 nac 0 91 Aia Irr 994 Wim2 M Em Rigid clamp DC AC 10 100A 1V diameter 30mm HT4004 Pnom 2520 kW st Sensor for irradiation measurement HT304 Tcell 42 0 C Ten 22 8 C iE Probe PT1000 for panel temperature PT300N AC DC power supply A0055 A0055 Rechargeable 3 7V CHON batt
14. led on the ground The problems involved in the installation of photovoltaic systems however are to be solved in terms of safety testing and maintenance requiring specific solutions INSTRUMENTS FOR TESTING AND VERIFYING PHOTOVOLTAIC INSTALLATIONS Continuity of protective conductors with 200mA Insulation with test voltages of 50 100 250 500 1000V DC Tripping time and current of RCDs type A ACt up to 5O0mA Impedance Line Loop also with high resolution 0 1mQ and Ipsc calculation Total earth resistance with no RCD tripping Phase sequence DC AC TRMS voltage current on single phase systems DC AC TRMS voltage current on three phase systems DC AC powers on single phase systems DC AC powers on three phase systems Power factor cos amp on single three phase systems Energies on single phase and three phase systems Recording of mains parameters with programmable IP Maximum number of quantities contemporarily selectable Harmonic analysis of voltages currents up to the 49th order Detection of voltage anomalies dips peaks in 10ms Complete analysis according to EN50160 Inrush current of electric motors Voltage fast transients spikes with a resolution of 5us 200kHz Voltage unbalance NEG ZERO and Flicker Pst Pit Display of vector diagrams and waveforms of voltages currents Indication of recording autonomy Default and customizable recordings TFT touch screen colour display LCD custom backlit display
15. lligator clips KITGSCA Kit of 2 adapters with MCS compatible connectors KITPVMC3 MEASURING FINAL RESULT Results STC OK Graf IV STC OK Kit of 2 adapters with MC4 compatible connectors KITPVMC4 Een El a EE Rigid clamp 5 100A 1V AC diameter 20mm HTAOOBN Testing Recording in progress Testing i Numerical p results with M d ind Men l V curve Rigid clamp DC AC 10 100A 1V diameter 30mm HT4004 Reference cell for irradiation measurement HT304 Probe PT1000 for environmental and module temperature PT300N Mechanical inclinometer M304 ee Windows software optical USB cable C2006 TOPVIEW2006 Transport bag BORSA2051 User manual Calibration certificate ISO9000 INVERTER Rapid user guide Opzional accessories Rigid clamp AC 1 100 1000A 1V diameter 54mm HT96U Rigid clamp AC 10 100 1000A 1V diameter 54mm HT97U Rigid clamp DC AC 1000A 1V diameter 50mm HT98U SOLAR I V Direct measurement of l V SOLAR I V Detection of l V Curve on a string of Kit of belts for slinging the instrument over one s shoulder SP 0400 Curve on a string of PV PV modules with remote irradiance modules temperature measurements KIt of 2 cables banana 4mm Green Black 25m KITPVEXT25M Rigid transport suitcase VA400 Connector with magnetic tip 606 IECN Remote unit SOLAR 02 for recording irradiation and temperature INVERTER SOLAR I V CONNECTION SCHEME SINGLE PHASE PLANT
16. n Zonder kalibratiecertificaat kunt u er vanuit gaan dat de meter voldoet aan de fabrieksspecificaties maar aantonen kunt u dit niet Een testcertificaat van de fabrikant is te beknopt om de lineairiteit aan te tonen en is niet geregistreerd op naam wat wel degelijk een vereiste is AF25 ee SE KWS is een uniek servicesysteem voor uw meetinstrumenten met periodiek onderhoud en kalibratie Veel zaken worden voor u geregeld zodat u zonder zorgen gebruik kunt maken van uw meetinstrumenten mk De prijs staat vast voor de levensduur van het Reparatie en preventief onderhoud instrument mits de KWS behandeling volgens Gratis oproep met het advies voor herkalibratie herkalibratieadvies periodiek wordt uitgevoerd Controle op functionaliteit van het instrument mer NH in het EURO INDEX kalibratielaboratorium Vijf jaar historie voor alle gegevens EE Geen arbeidsloon bij de KWS behandeling 10 korting op onderdelen e Kalibratie voor justage voorkalibratie Serienummerregistratie indien mogelijk Franco retourlevering Indien nodig justage en na kalibratie Het kalibratielaboratorium van EURO INDEX beschikt sinds 21 augustus 1997 over een RvA accreditatie naar NEN EN ISO IEC 17025 Deze accreditatie geldt voor verschillende grootheden zoals gespecificeerd in de scope bij accreditatienummer K105 op va nl Test en meetinstrumenten voor grootheden die deel uitmaken van de gespecificeerde scope kunnen word
17. nt practical problems In a typical building installation modu les are usually placed on the roof and the inverter is often in the basement Such a condition is critical because to test the equipment both electrical and environmental parameters are to be measured simultaneously even though very far from each other Only the use of suitable equipment can grant correct measurements car ried out in a suitable fast and conve nient way MAINTENANCE I V400 AND SOLAR I V The outdoor installation with consequent exposure to extreme environmental con ditions can lead to a rapid deterioration of the modules as well as a sharp de crease in the performance of the whole photovoltaic installation The energy pro duced and the consequent economic benefit can be reduced considerably It should be advisable therefore to periodi cally check the installation comparing the performance of the modules as specified by their manufacturer By measuring the module feature and comparing it with the rating you can assess whether they are granting adequate performances whether any decrease falls within the natural per formance decay or whether one or more modules are faulty In this case you can pinpoint the damaged modules and prom ptly replace them While the costs of components are decreasing and their performance is significantly booming up the photovoltaic installations are very common either on buildings roofs or instal
18. nterface optoisolated optical USB port IEC EN61010 1 IEC EN61010 031 IEC EN61010 032 D M 19 02 07 Guida CEI 82 25 Safety Measuring accessory safety Testing systems PV Measures IEC EN60891 Meas of output current from module string up to 10A DC Measurement of solar irradiation W m2 with reference cell Insulation double insulation Measurement of module temperature automatic or by means Pollution degree 2 of external probe Measurement category CAT II 1000V DC CAT III 300V to Meas of output DC and nominal power from module string earth Max 1000V between inputs synchronization with remote unit SOLAR 02 Numerical and graphical display of l V characteristic Dimensions 230xl6ox omm Measurement of the resistance of photovoltaic module series Weight batteries included 1 3kg Mechanical inclinometer for the detection of the incidence angle of solar irradiation 4 terminal measuring method Extrapolation to standard test conditions STC Evaluation of testing result OK NO Management of up to 30 types of photovoltaic modules in the internal database Common characteristics Internal memory for data saving gm Recalling results on the display Optical USB port for PC connection Help on line on the display SOLAR I V ACCESSORIES SUPPLIED ETE Series accessories Remote unit to record irradiation and temperature SOLAR 02 Kit of 4 cables with 4mm banana plugs 4 a
19. sis of mains quality in compliance with standard EN50160 harmonic analysis analysis of voltage anomalies Flicker unbalance etc The management software TopView also provides the possibility of creating professional reports which can be customized by adding the company s logo the customer s data comments etc FUNCTIONS DC AC TRMS single three phase voltage measurement DC AC TRMS single three phase current measurement DC AC single three phase power measurement AC single three phase energy measurement Measurement of power factor single three phase Measurement of solar irradiation W m Measurement of environmental and module temperature Evaluation of testing result OK NO Recording of voltage and current harmonics up to the 49th Recording of voltage anomalies dips peaks Flicker analysis in compliance with standard EN50160 Recording of starting currents with a resolution of 1Oms Recording of fast voltage spikes with a resolution of 5us Analysis of mains quality in compliance with EN50160 Numerical and graphical display of each quantity Recalling results on the display TFT colour display with touch screen Power supply with rechargeable Li ION battery Memory extension by means of CF card Data transfer to external USB memory memory stick USB port for PC connection Help on line on the display SOLAR3OON GENERAL CHARACTERISTICS Display Power supply Internal memory Memory extension PC inter
20. vironmental parameters incident irradiation of modules temperature of environment and modules and electric parameters continuous power alternating power etc Typically modules and inverter can be positioned even at several tens of meters of distance thus forcing the operator to carry out measurements in different places far from each other at the same time To carry out these operations connections by means of long cables or wireless radio connections could be necessary but both these solutions are not acceptable Cables could hamper the operator s movements or be a hindrance while radio waves would be attenuated by floors reinforced concrete or metal structures thus making communication impossible In order to avoid the above mentioned problems and to carry out measurements with the necessary contemporaneity SOLARS3OON is provided with a remote unit synchronized with the main unit The remote unit is positioned next to the photovoltaic modules and it is connected to the probes for measuring environmental parameters irradiation and temperature SOLAR300N is connected upstream and downstream of the inverter in order to acquire the electric parameters continuous power and alternating power The synchronization between the two units guarantees the necessary contemporaneity of measurements the two separate and independent units make measurements comfortable and safe SOLAR300N is also a powerful instrument for the complete analy
21. with 4mm banana plugs 4 alligator clips Kit of 2 adapters with MC3 compatible connectors KITPVMC3 KITGSC4 ENTER TO SELECT Graf l V D OK Results STC Kit of 2 adapters with MC4 compatible connectors KITPVMC4 Selection Selection Selection Reference cell for irradiation measurement HT304 Simple and intuitive user Graphical display of an I V curve Numerical display of results with Creation of a cutomizable interface with OK result OK result database of photovoltaic modules Mechanical inclinometer M304 Windows software optical USB cable C2006 TOPVIEW2006 Transport bag BORSA2051 User manual Remote unit 1 EE UN SOLAR O2 for recording Calibration certificate ISO9000 irradiation Opzional accessories and temperature en connected to RF Probe PT1000 for cell temperature measurement PT300N M me for slinging the instrument over one s SP 0400 shoulde s s Remote unit to record irradiation and temperature SOLAR 02 1 Kit of 2 cables banana 4mm Green Black 25m KITPVEXT25M HT 304 I Rigid transport suitcase VA400 for solar irradiation measurement j Direct measurement of l V I V 400 Curve on a string of PV modules Mechanical inclinometer M304 for the detection of the incidence angle of solar irradiation SOLAR 02 INVERTER Detection of l V Curve on a string of PV modules with remote irradiance temperature measurements SOLAR I V