Home

LI800, LI1100, LI1500 User Manual

image

Contents

1. Warranty On Off On Off On Off least one piece of equipment from the UPS Wait 5 seconds reset the circuit 4 breakerandtestariihe J S Exclusive Remedies Under Limited Warranty Your exclusive remedy and Legacys sole obligations are as follows for the Product If a the Legacy Product you purchased and still own is defective in material or workmanship under this Limited Warranty or any applicable warranty imposed by law and b all Limited Warranty requirements have been met Legacy will repair or replace the Product if it proves to be defective in material or workmanship during the Warranty Period TECHNICAL SPECIFICATIONS LI800 L11100 LI1500T Capacity VA 800VA 1100VA 1500VA Capacity Watts 550W 700W 1000W Input Making a Limited Warranty Claim To make a Limited Warranty claim on a Product you must do the following 1 Complete and return the Legacy Warranty Registration Card or provide reasonable proof of purchase for example a sales receipt that establishes you as the Initial Customer the original end user consumer purchaser of the Product and prove that the Product was purchased within three 3 years of the event for which you want to make a claim for warranty service 2 Call Legacy at 608 565 5878 or 800 859 5711 toll free write to Legacy Power Conversion at N9246 Hwy 80 South Suite 7 Necedah WI 54646 or e mail Legacy at service lpc ups com within ten 10 days of the event for wh
2. LEGACY Lineage UPS LI800 L11100 LI1500 User Manual K01 1120001 00 SAFETY WARNINGS SAVE THESE INSTRUCTIONS This manual contains important safety instructions Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate your UPS This equipment can be operated by any individuals with no previous training The socket outlet shall be installed near the equipment and easily accessible During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA Attention hazardous through electric shock Also with disconnection of this unit from the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary Do not dispose of batteries in a fire the battery may explode Do not open or mutilate the battery or batteries released electrolyte is harmful to the skin and eyes INSTALLING YOUR UPS SYSTEM UNPACKING Inspect the UPS upon receipt The box should contain the following UPS Unit SeeUPS2020 Software Disk Serial Interface Cable DB 9 USB Device Cable Telephone Cable User Manual SeeUPS2020 Software User Manual HOW TO DETERM
3. 54646 and its phone number is 608 565 5878 or 800 859 5711 toll free Legacy is the warrantor under this Limited Warranty You may also contact Legacy on the Internet at www lpc ups com
4. continuously it indicates that the UPS is compensating MAX 12 for a high utility voltage REAR PANEL DESCRIPTION Battery Backup and Surge Protection Outlets _al fa 7 ome i The UPS provides 4 battery powered and surge protected outlets for connected equipment to insure ojcs i l D temporary uninterrupted operation during a power failure and against surges and spikes T l alc Ina a D a e w al an ro Surge Protection Outlets _al fa 7 eae J a S The UPS provides 3 surge protected only outlets for connected equipments against surges and spikes w EJE paga o0 b l sdl cs J J Serial USB Port to PC This port allows connection and communication from the DB 9 serial or USB port on the computer to the UPS unit The UPS communicates its status to the SeeUPS2020 software This interface is also compatible with the UPS service provided by Windows 98 Windows ME Windows NT Windows 2000 Windows XP Windows Server 2003 and Mac OS 10X NOTE Only one of these two ports can be used as communication and control of the UPS unit at one time Ethernet RJ 45 Network Protection Ports These ports are the protection for your computer network device BATTERY REPLACEMENT AND STORAGE Contact your dealer or call the number in this manual for information on battery replacement Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the battery
5. equipments must be less than the maximum total power load of your UPS FO Pi PLUG IN a 2 Connect your UPS power cord into a two pole three wire grounding receptacle only Please avoid using extension cords and adapter plugs To maintain optimal battery charge leave the UPS plugged in at all times 3 Press the UPS power button to turn it on The Power On indicator will be illuminated in Green 4 Install your optional software and accessories To use the software simply connect the enclosed serial interface cable to the serial port on the UPS and an open serial port on the computer BASIC OPERATION FRONT PANEL DESCRIPTION Power Switch EN wL 4 ON OFF Power On Indicator Using Battery Indicator This LED is illuminated when the utility condition is normal and the UPS outlets are providing clean power free of surges and spikes O This illuminates during utility failure indicating that the battery is supplying power to the battery power supplied USING outlets BATTERY Boost Indicator er g This LED indicates that the UPS is operating in automatic voltage regulation mode When this indicator is flashing O illuminated continuously it indicates that the UPS is compensating MAX 14 30 for a low utility voltage BOOST Buck Indicator This LED indicates that the UPS is operating in automatic voltage regulation mode When this indicator is illuminated
6. under the supervision of personnel knowledgeable of batteries and their precautions Keep unauthorized personnel away from batteries CAUTION Use only the specified type of battery See your dealer for replacement batteries CAUTION The battery may present the risk of electrical shock Do not dispose of batteries in a fire as it may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mutilate the batteries Release electrolyte is harmful to the skin and eyes and may be toxic CAUTION A battery can present a high risk of short circuit current and electric shock Take the following precautions before replacing the battery 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 DO NOT lay tools or other metal parts on top of battery or any battery terminals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH A GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance applicable to a UPS and a remote battery supply not having a grounded circuit STORAGE First turn off your UPS and disconnect its power cord from the wall outlet Disconnect all cables connected to the UPS to avoid battery drain To store your UPS for an extended period cover it and store
7. INE THE POWER REQUIREMENTS OF YOUR EQUIPMENT _ Insure that the equipment plugged into the battery power supplied outlets does not exceed the UPS unit s rated capacity 800VA 550W for LI800 1100VA 700W for LI1100 1500VA 1000W for LI1500 If rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down or the circuit breaker to trip N If the power requirements of your equipment are listed in units other than Volt Amps VA convert Watts W or Amps A into VA by doing the calculations below Note The below equation only calculates the maximum amount of VA that the equipment can use not what is typically used by the equipment at any one time Users should expect usage requirements to be approximately 60 of below value TO ESTIMATE POWER REQUIREMENTS 1 Watts W x 2 0 VA or Amps A x 120 VA 2 Add the totals up for all pieces of equipment and multiply this total by 0 6 to calculate actual requirements There are many factors that can affect the amount of power that your computer system will require The total load that you will be placing on the battery powered outlets should not exceed 80 of the unit s capacity HARDWARE INSTALLATION GUIDE 1 Connect the equipment to your UPS outlets Items such as copiers laser printers vacuums space heaters paper shredders or other large electrical devices should not be connected to the UPS Please assure that the total loads of your
8. Recharge Time Indicators Power On Using Battery Boost Buck CONDITIONS TO THE LIMITED WARRANTY The Limited Warranty is the only and the exclusive express warranty of Legacy with respect to the Product This exclusion of other express warranties applies to written and oral express warranties LIMITATION THE LIMITED WARRANTY DOES NOT COVER The Limited Warranty is intended to exclusive rights and remedies and replace any other rights to the extent allowed by law 1 As to the Legacy Product the limited warranty does not cover or apply to misuse modification operation or storage outside environmental limits for the Products in transit in shipment or in storage damage or deterioration improper operation or maintenance or use with items or equipment not designed or intended for use with the product Audible Alarms On Battery Low Battery Overload Environmental Operating Temperature 32 F to 95 F 0 C to 35 C Operating Relative Humidity 0 to 95 NON CONDENSING Communication The Limited Warranty Does Not Apply Unless The Initial Customer 1 Has properly connected the Product and the Connected Equipment to properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code ANS NFPA 70 without the use of any adapters extension cords of other connectors SeeUPS2020 Software Windows 98 ME 2000 NT XP Server 2003 Mac OSX Linux 2 Has provided a suitable and prop
9. er environment for use and installation of the Product and Connected Equipment 4 Has operated the Product at all times within the limitations on the Product s VA capacity as stated in this User Manual Auto Charger Auto Restart USB SNMP HTTP Network Optional Legacy Does Not Cover or Undertake Any Liability in Any Event for Any of the Following 1 Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or surges on properly installed grounded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Ethernet lines when properly installed and connected Damage from any circumstance described as excluded above with respect to the product 4 Damages from fire flood wind rain rising water leakage or breakage of plumbing abuse misuse or alteration of either the product or the Connected Equipment Exclusion of Consequential and Other Damages The sole and exclusive remedies of the Initial Customer are those provided by the Limited Warranty Legacy excludes any liability for personal injury under the Limited Warranty Legacy excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property loss of profits business interr
10. es To the extent necessary to comply with those laws the terms of the Limited Warranty should be read to adjust to those requirements only to the extent necessary to comply with such local law Off Max boost 14 of input voltage for output regulation while input voltage is from 6 to 17 under nominal Flash If you are an Initial Customer you are asked to read the following terms and conditions carefully before using the Product By using the Max boost 30 of input voltage for output Product you consent to be bound by and become a party to the Limited Warranty If you do not agree to the terms and conditions of the regulation while input voltage is from 18 Limited Warranty you should return the Product for a full refund prior to using it to 29 under nominal B REGISTRATION Max buck 12 of input voltage for output a 2 regulation while input voltage is from 8 Legacy requests that you complete and return the Warranty Registration Card enclosed with the Product or register the Product at its to 25 over nominal website www I pc ups com to establish that you are the Initial Customer of the Product and therefore entitled coverage under the Limited Warranty Registration is not required for Limited Warranty coverage but note if you do not complete a registration card you will be required to provide proof of purchase as described below to have the benefits of this Limited Warranty Utility Failure The UPS is providing ba
11. ich you want to make a claim 3 When you contact Legacy identify the Product the Purchase Date and request Return Materials Authorization RMA information from Legacy 4 Pack and ship the Product to Legacy as instructed in your RMA Show the RMA code on the shipping label or include it with the Product Input Voltage Range 85Vac 150Vac Frequency Range 50 60 Hz 3Hz Output On Battery Output Voltage Pure Sine Wave at 120Vac 7 47 53Hz for 50Hz nominal 57 63Hz for 60Hz nominal On Utility Circuit Breaker On Battery Internal Current Limiting On Battery Output Frequency Overload Protection You MUST prepay all shipping costs and you are responsible for packaging and shipment Surge Protection and Filtering Yes Network Protection RJ45 One In One Out Physical Total of UPS Receptacles Lightning Surge Protection Legacy will inspect and examine the Product within ten 10 days of receipt If the Product is not as warranted Legacy will repair or replace the Product and return it to you at Legacy s expense or if Legacy is unable to or decides not to repair or replace the Product if defective within a reasonable time Legacy will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required 7 NEMA 5 15R Maximum Dimensions 30 9cm 14 1cm 18 4cm Weight Kg 12 8 15 5 Battery Sealed Maintenance Free Lead Acid Battery Hot Swappable Battery Typical
12. ou must use the cable that came with the connected unit The serial cable is connected to Check the back of the computer for an additional serial port Move the wrong port the cable to this port SeeUPS2020 is inactive all icons are gray The unit is not providing batter Shutdown your computer and turn the UPS off Wait 10 seconds and power J d turn the UPS back on This should reset the unit You must use the cable that was included with the unit for the ee eee we er software and the unit to be able to communicate DEFINITIONS FOR ILLUMINATED LED INDICATORS LIMITED WARRANTY In purchasing LI800 LI1100 LI1500 in the United States or Canada the original end user receives a Limited Warranty from Legacy Power Conversion Inc for ease of reading referred to as Legacy The Limited Warranty is intended to be the original end user s exclusive rights and remedies Moras Condition Circuit Break Limited Warranty The original end user referred to as the Initial Customer receives an express limited warranty referred to as the reaker Limited Warranty for the LI800 LI11100 LI1500 purchased from Legacy referred to as the Product The Limited Warranty is for the Set Product itself The Limited Warranty is subject to the terms set forth below Additionally State or Provincial law may adjust the terms of the Limited Warranty or the State or Province may impose additional obligations or additional implied warranti
13. ttery power to the Battery Power Supplied outlets LIMITED WARRANTY Utility Failure The UPS is providing battery power The rapid beeps indicate the battery will Legacy warrants to you the Initial Purchaser that the Product will be free from defects in material and workmanship for three years run out of charge within a few minutes from the date of original purchase subject to the terms of this Limited Warranty This Limited Warranty gives you specific rights and you may have other rights which vary from State to State or Province to Province Overload Turn the UPS off and l t beeps or ped oa e T a Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose if applicable to the Product is limited in duration to the On Off On Off On Off least one piece of equipment from the i T i i Aa rapid UPS Wait 5 seconds reset the circuit period of ownership by the Initial Customer This provision shall NOT create any Implied Warranty or Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product NOTE Some States and Provinces do not allow limitations on beeps breaker and restart the UPS uae wee how long an implied warranty lasts so the above limitation may not apply to you Off Off Off On Off Off Overload Turn the UPS off and unplug at To be covered you must still be the owner of the Product at the time of the failure that results in the claim made under this Limited
14. uption loss of information or data This exclusion applies even though damage or loss is caused by negligence or other fault NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you DO NOT USE FOR HIGH RISK ACTIVITIES Legacy does not sell the Products for use in high risk activities The Product is not designed or intended for use in hazardous environments requiring fail safe performance including the operation of nuclear facilities aircraft navigation or communication systems air traffic control weapons systems life support or for use in any circumstance in which the failure of the Product could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of life support device collectively High Risk Activities Legacy expressly disclaims any express or implied warranty of fitness for High Risk Activities Legacy does not authorize use of any of its products use in any High Risk Activities ANY SUCH USE IS IMPROPER AND IS A MISUSE OF LEGACY PRODUCTS The Limited Warranty is governed by the laws of the United States and the State of Wisconsin without reference to conflict of law principles The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded Contact Information Legacy s address is N9246 Hwy 80 South Necedah WI
15. with the battery fully charged Recharge the battery every three months to insure battery life If the battery remains uncharged for an extended period of time it may suffer permanent loss of capacity TROUBLE SHOOTING Batteries are not fully charged Recharge the battery by leaving the UPS plugged in Contact Legacy Power Conversion at service pc ups com or 800 859 5711 Problem The UPS does not perform expected runtime Battery is slightly worn out The on off switch is designed to prevent damage by rapidly turning it off and on The unit is not connected to an The unit must be connected to a 110 120v 60Hz outlet AC outlet Contact Legacy Power Conversion at service pc ups com or The battery has failed 800 859 5711 Contact Legacy Power Conversion at service pc ups com or 800 859 5711 Turn the UPS off Wait 10 seconds and then turn the UPS on The UPS will not turn on Mechanical problem Circuit breaker is tripped due to overload Turn the UPS off and unplug at least one piece of equipment Wait 10 seconds reset the circuit breaker and then turn the UPS on Outlets do not provide power to equipment Batteries are discharged Allow the unit to recharge for at least 4 hours Unit has been damaged by a Contact Legacy Power Conversion at service pc ups com or surge or spike 800 859 5711 Connect the serial cable to the UPS unit and an open serial port on The serial cable is not the back of the computer Y