Errata Sheet
Contents
1. New limits starting with date codes of week 39 2010 are valid for whole temperature and VDD range Change in Vos limits will not cause any impact to the LVDS communication because the remaining 3 specified parameters Voy Vo and Vop for the LVDS communication are not affected PLL TC P005 PLL Parameters for fyco gt 780 MHz When the PLL is configured for VCO frequencies fyco gt 780 MHz the specified PLL parameters may be exceeded Workaround Select the values for the P N and K2 dividers such that the desired target frequency fp is achieved with fyco 780 MHz TC1797 QS AC 91 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints 4 Application Hints ADC _AI H002 Minimizing Power Consumption of an ADC Module For a given number of A D conversions during a defined period of time the total energy power over time required by the ADC analog part during these conversions via supply Vopy is approximately proportional to the converter active time Recommendation for Minimum Power Consumption In order to minimize the contribution of A D conversions to the total power consumption it is recommended 1 to select the internal operating frequency of the analog part fap OF fana respectively near the maximum value specified in the Data Sheet and 2 to switch the ADC to a power saving state via ANON while no conversions are performed Note that a certain wake up time is required bef
2. ai I gt gt gt Start shifted prog timer rate prog timer rate Note the programmed timer rate is much longer than the conversion time this means that the fault is much smaller than in the picture Figure 1 Timing concerning equidistant multiple timers TC1797 QS AC 42 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Workaround Use one timer base in combination with neighboring trigger and selection by software which result has to be taken into account FIRM _TC 010 Data Flash Erase Suspend Function This problem affects devices with microcode version V11 see FIRM_TC HO00 for identification of the microcode version A sector DFx in the Data Flash may not be correctly erased when two successive erase operations are executed without any programming between the erase operations as described in the following sequence x y 0 or 1 x y 1 A Program Flash sector or a Data Flash sector DFy or DFx has been erased 2 An erase command on Data Flash sector DFx is issued 3 While the erase operation on sector DFx is in progress during a certain critical time window a programming command on sector DFy is issued i e the erase operation on sector DFx is suspended In other words potentially critical sequences are e Erase PFLASH gt erase DFx gt program DFy suspend erase DFx or Erase DFy gt erase DFx gt program DFy suspend erase DFx or E
3. Example 2 PCP reads register SRS with first instruction GPTA is configured with fractional divider STEP 38E CONECYC 0g FPIDIV 2 fpcp 2 frp This results in 16 7 2 max 4 1024 DIV 910 1 2 or 9 max 4 2 2 or 9 max 4 4 where max 4 4 4 i e 924 is true i e this configuration is not affected by the corner case described above Recommendation In case a system is affected by the corner case described above the service routine PCP channel program should read the status flags in SRS again 2 1 GPTA module clock cycle after the first read operation to ensure earliest possible recognition of all events e g Service Routine PCP Program Entry Read SRS if flag is set handle requesting source clear corresponding flag via register SRSCx Ensur lapsed time to next read of SRS in Loop is 2 1 GPTA module clock cycle since routine entry Loop Read SRS exit if all flags are 0 Handle requesting source s clear corresponding flag s via register SRSCx or when the GPTA module clock is relatively high e g Service Routine PCP Program Entry Ensure time to first read of SRS in Loop is 2 1 GPTA module clock cycle since routine entry Loop Read SRS exit if all flags are 0 Handle requesting source s clear corresponding flag s via register SRSCx TC1797 QS AC 103 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints Note
4. Change Summary Table 4 Functional Deviations cont d Functional Short Description Cha Pa Deviation nge ge FlexRay_Al 082 After detecting low level beyond 59 gdWakeupSymbolIRxWindow the node may complete FlexRay_Al 083 Irregular sync frame list exported in state 60 Coldstart_Gap FlexRay_Al 084 Corruption of frame received in slot N by 61 second frame reception before action point FlexRay_Al 085 Cycle filtering in slot 1 62 FlexRay_Al 086 Bit IBFS of Register CUST1 always 0 62 FlexRay_Al 088 A sequence of received WUS may 63 generate redundant SIR WUPA B events FlexRay_Al 089 Rate correction set to zero in case of 64 SyncCalcResult MISSING_TERM FlexRay_Al 092 Initial rate correction value of an 64 integrating node is zero if pMicrolnitialOffsetA B 0x00 FlexRay_Al 093 Acceptance of startup frames received 65 after reception of more than gSyncNodeMax sync frames FlexRay_Al 094 Sync frame overflow flag EIR SFO may be 66 set if slot counter is greater than 1024 FlexRay_Al 095 Register RCV displays wrong value 67 FlexRay_Al 096 Noise following a dynamic frame that 67 delays idle detection may fail to stop slot FlexRay_Al 097 Loop back mode operates only at 10 MBit s 68 FlexRay_Al 099 Erroneous cycle offset during startup after New 69 abort of startup or normal operation FlexRay_Al 100 First WUS following received valid WUP New 70 TC1797 QS AC may be ign
5. FlexRay_Al 073 Switching from loop back test mode at low bit rate to nor mal active takes longer then expected Description When the baud rate prescaler PRTC1 BRP 1 0 is configured to 5 or 2 5 MBit s at least one loop back test is performed at channels A B or both and then a startup without a preceding hardware reset is initiated The E Ray will not be able to store a non null frame received on the channel s on which a loop TC1797 QS AC 53 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations back test was performed into its message memory and will raise the EIR MHF error interrupt flag The problem persists until the E Ray has transmitted its first non null frame on the same channel s Scope The erratum is limited to test cases where loop back is used with the baud rate prescaler PRTC1 BRP 1 0 configured to 5 or 2 5 MBit s and where there is no hardware reset before a startup is initiated Effects The error interrupt flag EIR MHF is raised and the contents of the first received non null frames will be lost Workaround Run loop back tests with 10 MBit s PRTC1 BRP 1 0 00g or perform a hardware reset after a loop back test FlexRay_Al 074 Integration successful on X and integration abort on Y at the same point in time leads to inconsistent states of SUC and GTU Description In case of integration successful on X and integration abort on Y at the same point in ti
6. It is recommended to select the protected two pin DAP mode CBS_OSTATE DJMODE 013 instead if unintentional and non recoverable loss of the tool connection e g due to EMC shall be prevented safely TC1797 QS AC 76 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations OCDS_TC 025 PC corruption when entering Halt mode after a MTCR to DBGSR In cases where the CPU is forced into HALT mode by a MTCR instruction to the DBGSR register there is a possibility of PC corruption just before HALT mode is entered This can happen for MTCR instructions injected via the CPS as well as for user program MTCR instructions being fetched by the CPU In both cases the PC is potentially corrupted before entering HALT mode Any subsequent read of the PC during HALT will yield an erroneous value Moreover on exiting HALT mode the CPU will resume execution from an erroneous location The corruption occurs when the MTCR instruction is immediately followed by a mis predicted LS branch or loop instruction The forcing of the CPU into HALT takes priority over the branch resolution and the PC will erroneously be assigned the mispredicted target address before going into HALT e Problem sequence 1 e 1 CPS injected MTCR instruction to DBGSR sets HALT Mode e 2 LS based branch loop instruction e 3 LS based branch loop is mispredicted but resolution is overridden by HALT e Problem sequence 2 e 1 User code MTCR instruction to DBGSR s
7. OCDS TC 021 TriCore breaks on de assertion instead of assertion of break bus The central OCDS building block Cerberus provides two Break Buses All break sources can be individually enabled to assert one of these buses while all break targets can be programmed to react on the assertion of one of the break buses The break target TriCore however does not react on the assertion transition 0 to 1 of the break bus as seen in the associated status bit MCDBBSS BBSx like all the other break targets but on the deassertion transition 1 to 0 of the status bit It is therefore not possible to Stop the TriCore together with another core e g PCP at the same instant e Use a single transition of an external signal connected to any BRKIN pin to cleanly break the whole SoC Workaround e All internal break sources can be programmed in a manner so that the break event is encoded as a pulse For simple sources e g SBCU this is trivial for complex sources e g MCDS a different trigger logic may be required The temporal distance of the break requests to different targets can thus be kept low relative to the intrinsic core specific delays e g caused by pipeline flushing e External break sources may be redesigned to deliver an active low pulse also TC1797 QS AC 75 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations OCDS_TC 024 Loss of Connection in DAP three pin Mode Devices of the Audo
8. 25 01 2011 Infineon Errata Sheet Application Hints Workaround Ensure that there are no PRAM locations with an incorrect parity bit by initialising every PRAM location with parity checking enabled prior to enabling trapping of PRAM parity errors PCP_TC H005 Unexpected parity errors when address 0 of CMEM is faulty When CMEM parity error detection is enabled and its content at address 0 is faulty only an access to the mentioned address should raise the parity error flag However in this specific situation a FPI read access to any CMEM location will result in a parity error PCP_TC H006 BCOPY address alignment error may affect next channel FPI operation When a BCOPY is executed starting on a non aligned address e g address Ox 4 or Ox C for double word burst BTR2 the channel will perform an error exit If the first FPI instruction of the next channel is a byte or half word FPI RMW or FPI write the data written by this instruction may be corrupted due to the previous error PCP_TC H007 Do not use priority 0 to post interrupt to CPU Posting interrupts with priority 0 to CPU bus is not permitted because the CPU will never acknowledge the interrupt and thus the service request node will never be cleared If this is repeated sufficient times to fill the CPU queue then the PCP would stall and the system would have to be reset to restore PCP operation As well care has to be taken when using a lower amount of arbitrati
9. Scope The erratum is limited to cases where the CLEAR_RAMS command is applied during E Ray operation The execution of the CLEAR_RAMS sequence after hard reset is not affected Effects Execution of the CLEAR_RAMS command does not reset the first word of an E Ray internal RAM to zero Workaround Write Ox00000000 to any address of IBF directly before applying CLEAR_RAMS command FlexRay Al 081 Write accesses to ERAY_NDIC and ERAY_MSIC can fail if ERAY_CLC FMC gt 2 Description The Registers NDIC1 NDIC4 and MSIC1 MSIC4 are only accessible if CLC RMC is 1 Frequency fsys Workaround If the module runs with divided clock CLC RMC gt 1 the RMC field has to be set to 1 before accessing these registers FlexRay Al 082 After detecting low level beyond gdWakeupSymbolRx Window the node may complete Description TC1797 QS AC 59 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations In case of a WUP that starts with a duration at the LOW level that is longer than n gdWakeupSymbolRxWindow but shorter than n gdWakeupSymbolRxWindow gdWakeupSymbolRxLow followed by a duration of at least gdWakeupSymbolRxldle at the HIGH level and followed by a duration of at least gd WakeupSymbolRxLow at the LOW level the last part of this received within a window with a duration of at most gdWakeup SymbolRxWindow then this WUP is detected as valid while it should be considered invalid Scope T
10. Such situation will not be detected by the starvation protection Workaround Avoid 64 bit CPU to PCP PRAM CRAM accesses GPTA_TC H004 Handling of GPTA Service Requests Concerning the relations between two events request_1 request_2 from different service request sources that belong to the same service request group y of the GPTA module two standard cases 1 2 and one corner case can be differentiated Case 1 When request_2 is generated before the previous request_1 has been acknowledged the common Service Request Flag SRR of service request group y is cleared after request_1 is acknowledged Since the occurrence of request_1 and request_2 is also flagged in the Service Request State Registers TC1797 QS AC 100 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints srs all request sources can be identified by reading SRS in the interrupt service routine or PCP channel program respectively Case 2 When request_2 is generated after request_1 has been acknowledged both flag SRR and the associated flag for request_2 in register SRS are set and the interrupt service routine PCP channel program will be invoked again Corner Case When request_2 is generated while request_1 is in the acknowledge phase and the service routine PCP channel program triggered by request_1 is reading register SRS to determine the request source then the following scenario may occur Depending on the relations between modu
11. The EBU has the facility for the flash clock to run continuously by setting one of the BUSRCONx BFCMSEL to 0g In this case as all attached devices see the same clock then all accesses requiring a flash clock will use the BUSRAPx EXTCLOCK setting from the region which has BUSRCONx BFCMSEL 0 when determining the correct delays for the various control signals enabled by the ECSE and EBSE bits However no distinction was made for asynchronous regions to enable them to use a separate method of delay calculation so if a continuous flash clock is enabled signal delays for asynchronous accesses will be calculated using the same EXTCLOCK value as that used for synchronous accesses instead of the EXTCLOCK value in the registers of the region being accessed Workaround If the continuous flash clock mode is in use adjust the phase lengths for the asynchronous regions to compensate for the modified signal delays EBU_TC 022 Write Data Delay Control for Asynchronous Memory Ac cesses The EBU allows the timing of the write data driven onto the EBU_AD 31 0 pins to be adjusted using the EBU_BUSWCONx ECSE and EBU_BUSWAPx EXTCLOCK register fields This delay mechanism is not working as specified for asynchronous write accesses e The time at which write data is disabled cannot be delayed by half a clock cycle Register settings where a half clock cycle delay would be expected will result in a full clock cycle of delay TC1797 QS AC 40 115 Rel 1
12. the delay in servicing the trap may be of concern In addition if interrupts are re enabled within the interrupt handler then the delay in returning to the trap handler will be further extended by the handling of any additional higher priority interrupt requests which may occur However once processing of the initial interrupt handler is complete and the RFE instruction executed to return to the trap handler interrupts are correctly disabled immediately and the trap handler will continue even if further interrupts are pending when the RFE instruction is executed Another point to note is that this issue can cause some assumptions made in system software to be invalid For example ifa system does not allow interrupts or traps to re enable interrupts then it would have been safe to assume that whenever a trap or interrupt is entered that the code that has been suspended and hence the state information saved in the CSA is for a user task and TC1797 QS AC 25 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations typically non privileged Unfortunately with this issue that premise no longer holds the code interrupted and state saved in a CSA can be that of a privileged trap handler Dealing with this changed circumstance is easy provided it is considered whenever CSA s are examined or manipulated Workaround As described previously the main problem associated with this erratum is the delay that may be incurred
13. 4 25 01 2011 Infineon Errata Sheet Functional Deviations e The time at which write data is enabled is never delayed The bus will always be driven as if no delay was in effect If the register settings require the data to be delayed then invalid data will be driven for the delay period e The time at which valid write data is driven cannot be delayed by half a clock cycle Register settings where a half clock cycle delay would be expected will result in no delay being applied This results in the timing detailed in the table below where CP1 is the first clock cycle of the command phase DHn is the last clock cycle of the Data Hold Phase and Tc is one period of the EBU clock Table 7 Write Data Signal Timing EXTCLOCK is set to Driven at Removed at Delay Delay Delay Delay Disabled Enabled Disabled Enabled 00 Start of Start of End of End of DHn CP1 CP1 DHn Tok O1 10g 11 Start of End of End of DHn End of DHn CP1 CP 1 Tok 1 DHn indicates the final Data Hold Phase If no Data Hold is programmed this will be CPn the final Command Phase 2 Data bus will be enabled at the beginning of CP1 Workaround Adjust the phase lengths for the asynchronous regions to compensate for the modified signal delays FADC _TC 005 Equidistant multiple channel timers The description is an example for timer_1 and timer_2 but can also affect all other combinations of timers Timer_1 and Ti
14. 95 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints This bit is edge sensitive A rising edge is used to trigger standby mode entry and a falling edge to trigger exit The EBU will also exit standby mode automatically when an LMB access occurs When this occurs the EBUCLC DISR standby request bit remains set Consequence When automatic exit from standby mode occurs the EBU_CLC DISR bit must be written first with 0 and then with 1 to use standby mode again EBU TC H009 Legal Parameters Allow an Invalid Page Mode Access to be Configured Configuring a region for a page_mode memory device BUSRCONx AGEN 6p and programming phase lengths of BUSRAP ADDRC 0001 BUSRAP AHOLDC 0001 BUSRAP CMDDELAY 0000 BUSRAP WAITRDC 0000p will cause the EBU state machine to transition from the one cycle Address Phase straight through to the last cycle of the first Burst Phase This transition is correct but will cause an incorrect address to be output by the EBU on all subsequent burst phases While the address generated during the address phase is correct the incremented address used during the second and subsequent burst phases is derived from the address used for the previous access This is because the stored address is only updated one clock cycle into the access so if the address starts incrementing after one cycle then the stored value has no time to update and the stored value from the previo
15. In case the condition in formula 1a or 1b is not true it would be possible to add n 2 Rx FPIDIV 1 NOPs ISYNC for CPU at the beginning of the service routine to extend the time until SRS is read Referring to Example 1 Rx 2 1 cycle is missing FPIDIV 2 n2 2 NOPs may be added before SRS is read to make this configuration uncritical Make sure the NOPs are not eliminated by code optimizations However basically it is still recommended to follow the general hint in paragraph Recommendation to improve code portability and become independent of cycle counting for individual configurations HYS_TC H001 Effective Hysteresis in Application Environment Pad hysteresis values are specified for a noise free environment The methodology of measuring the hysteresis on product level comprises noise due to clock signals program execution and device activity etc This can lead toa measurable hysteresis that is smaller than it really is Therefore hysteresis should be checked again in the real target application at system level The measured hysteresis in a noise free environment is within the specified product limits MSC _TC H007 Start Condition for Upstream Channel The reception of the upstream frame is started when a falling edge 1 to 0 transition is detected on the SDI line In addition reception is also started when a low level is detected on the SDI line while the upstream channel was in idle state i e when the u
16. In the current TriCore1 CPU implementation load accesses are initiated from the DEC pipeline stage whilst store accesses are initiated from the following EXE pipeline stage To avoid memory port contention problems when a load follows a store instruction the CPU contains a single store buffer In the case where a store instruction in EXE is immediately followed by a load instruction in DEC the store is directed to the CPU store buffer and the load operation overtakes the store The store is then committed to memory from the store buffer on the next store instruction or non memory access cycle The store buffer is only used for store accesses to local memories LDRAM or DCache Store instructions to bus based memories are always executed immediately in order A store buffer conflict is detected when a load instruction is encountered which targets an address for which at least part of the requested data is currently held in the CPU store buffer In this store buffer conflict scenario the load instruction is cancelled the store committed to memory from the store TC1797 QS AC 20 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations buffer and then the load re started In systems with an enabled MMU and where either the store buffer or load instruction targets an address undergoing PTE based translation the conflict detection is just performed on address bits 9 0 since higher order bits may be modified by tr
17. Inter rupts disabled A problem exists whereby an interrupt may be taken by the TriCore CPU upon exiting Halt mode even if interrupts are disabled at that point The problem occurs when an interrupt request is received by the TriCore CPU with the pending interrupt priority number PIPN higher than the current CPU priority number CCPN and interrupts are enabled In this case where only the CPU pipeline status is preventing the interrupt from being taken immediately the interrupt is latched and taken as soon as the pipeline can accept an interrupt This may cause unexpected behavior whilst debugging where TC1797 QS AC 29 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations interrupts are enabled before entry to Halt mode or where interrupts are temporarily enabled during Halt mode In this case an interrupt may be latched whilst the CPU is in Halt mode and subsequently disabling interrupts during Halt mode by setting ICR IE Og will not prevent the interrupt from being serviced immediately upon exit from Halt mode It should be noted that no corruption of the program flow is associated with this issue and that it affects debugging only primarily the debugger single stepping functionality The problem may or may not be visible whilst debugging dependent upon the implementation of single stepping by the debugger If single stepping is implemented by the debugger setting Break Before Make BBM breakpoin
18. LMB error conditions specifically if one is detected during a BTR2 read transfer from the DMI as reported by LEATT OPC and LEATT TAG TC1797 QS AC 37 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations DMI_TC 017 DMI line buffer is not invalidated by a write to OVC_OCON DCINVAL if cache off A problem exists whereby the DMI line buffer is not invalidated by a write to OVC_OCON DCINVAL when operating with the D cache turned off This means that the user cannot rely on a write to OVC_OCON DCINVAL to make sure that any stale data in the DMI line buffer is invalidated This can be a problem for users who want to use the OVC_OCON DCINVAL bit to ensure coherency between the DMI and background memory It should be noted that this problem is not encountered when the D cache is turned on When the D cache is turned on writing a one to OVC_OCON DCINVAL will correctly invalidate all clean cache entries and invalidate the DMI line buffer The problem only concerns systems with no cache or systems where the cache is turned off Detailed description D Cache turned on When D cache is turned on the DMI line buffer is only used as a performance enhancement mechanism with no logical existence to the user It is therefore not operating as a micro cache and the current issue does not apply When the dcache is turned on writing to OVC_OCON DCINVAL will always invalidate all clean lines in the dcache No stale data will
19. PCPN PCXI PIE PCXI UL PCXI PCXS and PCXI PCXO fields after storing the previous PCXI contents to memory e RSLCX now restores the full PCXI from the CSA However prior to the TriCore V1 3 6 architecture manual and as implemented by the TriCore1 3 core the following behaviour was present e BISR and SVLCX previously only updated the PCXI UL PCXI PCXS and PCXI PCXO fields after storing the previous PCXI contents to memory PCXI PCPN and PCXI PIE were not updated e RSLCX previously restored only the PCXI UL PCXI PCXS and PCXI PCXO fields of the PCXI The main implication of this change is that the value held in the PCXI PCPN and PCXI PIE fields following a BISR SVLCX or RSLCX instruction may be different between the TriCore1 3 1 and TriCore1 3 cores If it is necessary to determine the priority number of an interrupted task after performing a BISR or SVLCX instruction and before the corresponding RSLCX instruction then either of the following access methods may be used Method 1 For applications where the time prior to execution of the BISR instruction is not critical the priority number of the interrupted task may be read from the PCXI before execution of the BISR instruction mfcr d15 0xFE00 bisr lt New Priority Number gt TC1797 QS AC 93 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints Method 2 For applications where the time prior to execution of the BISR instruction
20. SRS is first instruction in CPU Interrupt Service sub routine Read Rp 16 if instruction reading SRS is first instruction in PCP channel program Rx number of extra fopy Or focp cycles to be added to Ro R4 or Rp respectively in case instruction reading SRS is not the first instruction in the corresponding service routine ACK number of fepu or fpcp cycles between interrupt request at CPU PCP site and clearing of request flag SRR ACK 7 constant for TriCore and PCP under all conditions independent from ICU PICU configuration e icu clock ratio between ICU and CPU clock icu 2 with bit ICR CONECYC 1 icu 4 with bit ICR CONECYC 0 e N maximum integer value of clock ratio fp fepra N 1024 STEP for Normal Divider mode DM 01 N 1024 DIV STEP 1 for Fractional Divider mode DM 10 3 where DIV means integer division FPIDIV clock ratio fopy Jepi for CPU and focp frp for PCP Example 1 PCP reads register SRS with first instruction GPTA is configured with fractional divider STEP E44 CONECYC Og FPIDIV 2 fpcp 2 ffpi This results in 16 7 max 4 1024 DIV 228 1 2 or 9 max 4 5 2 or 9 max 4 10 where max 4 10 10 i e 92 10 is false i e this configuration is critical with respect to the corner case described above TC1797 QS AC 102 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints
21. at the third instead of the second WUS Scope The erratum is limited to the reception of redundant wakeup patterns Effects Delayed setting of status interrupt flags SIR WUPA B for redundant wakeup patterns Workaround None FlexRay Al 101 READY command accepted in READY state Description The E Ray module does not ignore a READY command while in READY state Scope The erratum is limited to the READY state Effects Flag CCSV CSTI is set Cold starting needs to be enabled by POC command ALLOW_COLDSTART SUCC1 CMD 1001 TC1797 QS AC 70 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Workaround None FlexRay_ Al 102 Slot Status vPOC SlotMode is reset immediately when entering HALT state Description When the protocol engine is in the states NORMAL_ACTIVE or NORMAL_PASSIVE a HALT or FREEZE command issued by the Host resets vPOC SlotMode immediately to SINGLE slot mode CCSV SLM 1 0 00 According to the FlexRay protocol specification the slot mode should not be reset to SINGLE slot mode before the following state transition from HALT to DEFAULT_CONFIG state Scope The erratum is limited to the HALT state Effects The slot status vPOC SlotMode is reset to SINGLE when entering HALT state Workaround None OCDS AI 001 DAP restart lost when DAPO inactive To speed up the resynchronization after a loss of connection the DAP module can be forced back to the Ena
22. baud rate register to a value different from zero SSCBR gt 0 when the phase error should be used in master mode TC1797 QS AC 89 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Deviations from Electrical and Timing Specification 3 Deviations from Electrical and Timing Specification DTS _TC P001 Test Conditions for Sensor Accuracy Tisa Parameter Sensor Accuracy symbol T sa is not subject to production test it is verified by design characterization The corresponding note will be added in the next revisions of the Data Sheet FADC TC P003 Incorrect test condition specified in datasheet for FADC parameter Input leakage current at Ve gnp In datasheet the test condition for FADC parameter Input leakage current at Veacnp is specified as OV lt Vin lt Vopme The actual test condition is Vin OV It is not allowed to raise Veagnp above 1 5V when the FADC is in power down mode in order not to damage the device MSC_TC P001 Incorrect VQ limits for LVDS pads specified in Data Sheet Table 11 Parameters as per Data Sheet Parameter Symbol Min Max Unit Note Value Value Output offset Vos 1075 1325 mV voltage TC1797 QS AC 90 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Deviations from Electrical and Timing Specification Table 12 Actual Parameters Parameter Symbol Min Max Unit Note Value Value Output offset Vos 1060 1340 mV voltage
23. before the servicing of certain critical trap types such as NMI if no additional action is taken If this is an issue for a system then in order to minimize the impact of this erratum it is necessary to adapt the interrupt handlers to check for the occurrence of this issue and react accordingly The occurrence of this issue may be checked for by one of two methods dependent upon whether all trap classes or just a limited set are considered timing critical If it is required to check for the occurrence of this issue for all trap classes then this may be performed by checking the value of the PCXI PIE register bit within the interrupt handlers before any further context operations such as BISR are performed If PCXI PIE is clear such that no interrupt should have been taken then this indicates the occurrence of this issue Although when this method is used then it is preferred to check the value of PCXI PIE before any further context operations are performed it is possible to use this method after additional context operations have been performed In this case it is necessary to traverse the CSA list to check the required PCXI PIE value from the appropriate saved context If it is necessary within a system to check for the occurrence of this issue just for specific timing critical trap classes then this may be performed by examination of the return address held in the A11 register within the interrupt handler and compar
24. bit error this transaction will be re tried continuously on the LMB by the DMI LMB master and the CPU become deadlocked This situation would then only be recoverable by a Watchdog reset The problem exists within the DMI DLB which is used as a single cache line when no data cache is configured and as a streaming buffer when data cache is present As such the problem affects all load accesses to cacheable locations whether data cache is configured or not since the DLB is used in both cases Note This problem affects load accesses to the on chip Flash only Instruction fetches which encounter a similar condition bus error on later beat of block transfer behave as expected and will return a PSE trap upon any attempt to execute an instruction from a Flash location containing a double bit error Workaround As described previously this problem should not be encountered during normal operation and will only be triggered in the case of a double bit error being detected in an access to the on chip Flash However in order to remove the possibility of encountering this issue all load accesses to cacheable addresses within the on chip Flash should be made using natural alignment word transfers should be word aligned double word transfers double word aligned It is also possible to check for the occurrence of this problem by having some other master such as the PCP periodically poll the LBCU LEATT register to check for the occurrence of
25. consists of upper and lower page with 64 entries each These pages can be selected via page select register CUST1 IBF1PAG CUST1 IBF2PAG Due to IBFS is not functional see erratum FlexRay_Al 086 only the page of one IBF which is accessible can be switched in RAM test mode TC1797 QS AC 97 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints To switch to the other input buffer the mode must be changed from RAM test mode to normal mode TEST1 TMC 0 In normal mode the input buffer can be switched to the other input buffer by writing the register IBCR IBRH double buffer handling Now the page of the other input buffer can be switched FlexRay_ Al H004 Only the first message can be received in External Loop Back mode If the loop back TXD to RXD will be performed via external physical transceiver there will be a large delay between TXD and RXD A delay of two sample clock periods can be tolerated from TXD to RXD due to a majority voting filter operation on the sampled RXD Only the first message can be received due to this delay To avoid that only the first message can be received a start condition of another message idle and sampling 0 gt low pulse must be performed The following procedure can be applied at one or both channels e wait for no activity TEST1 AOx 0 gt bus idle e set Test Multiplexer Control to I O Test Mode TEST1 TMC 2 simultaneously TXDx TXENx 0 e w
26. deviation value of the sync frame is set to the deviation value of the previous non sync frame The positive shift of the non sync frame in direction of slot end results in a relative large positive deviation value order of magnitude of the parameter gdActionPointOffset With more than two sync frame senders within the cluster this large value is most probably not taken into account for correction term calculation because of the nature of the fault tolerant midpoint algorithm f the faulty value is used for offset correction term calculation the resulting offset shift will be corrected in the following cycles Workaround None FlexRay Al 065 For sync nodes the error interrupt flag EIR SFO may be set too late Description The E Ray acting as sync node does not consider its own sync frame for counting number of sync frames Thus it sets the error interrupt flag ETR SFO if it receives more than gSyncNodeMax GTUC2 SNM 3 0 sync frames Scope TC1797 QS AC 48 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations The erratum is limited to the case where a sync node receives exactly gSyncNodeMax sync frames from other sync nodes during one communication cycle Effects In the described case error interrupt flag EIR SFO is not set Workaround Avoid faulty configurations with more than gSyncNodeMax nodes configured to be transmitter of sync frames FlexRay Al 066 Time stamp of the wrong channel ma
27. different from read value 3 read register CUST1 If the status of IBF1PAG has changed from the first to the second read access IBF1 is accessible otherwise IBF2 is accessible and vice versa FlexRay Al 088 A sequence of received WUS may generate redundant SIR WUPA B events Description If a sequence of wakeup symbols WUS is received all separated by appropriate idle phases a valid wakeup pattern WUP should be detected after every second WUS The E Ray detects a valid wakeup pattern after the second WUS and then after each following WUS Scope The erratum is limited to the case where the application program frequently resets the appropriate SIR WUPA B bits Effects In the described case there are more SIR WUPA B events seen than expected Workaround Ignore redundant SIR WUPA B events TC1797 QS AC 63 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations FlexRay Al 089 Rate correction set to zero in case of SyncCalcRe sult MISSING_TERM Description In case a node receives too few sync frames for rate correction calculation and signals a SyncCalcResult of MISSING_TERM the rate correction value is set to zero instead to the last calculated value Scope The erratum is limited to the case of receiving too few sync frames for rate correction calculation SyncCalcResult MISSING_TERM in an odd cycle Effects In the described case a rate correction value of zero is applied in NO
28. is critical the priority number of the interrupted task may be read from the CSA pointed to by the PCXI after execution of the BISR instruction bisr lt New Priority Number gt mfcr di5 0xFEO0O Copy PCXI to d15 sh h d14 dl5 12 Extract PCX seg to dl14 insert d15 d14 d15 6 16 Merge PCX offset to d15 mov a al5 dl5 Copy to address reg ld bu di5 a15 0x3 Load byte containing PCPN Note that contrary to the TriCore architecture specification no DSYNC instruction is stricly necessary after the BISR or SVLCX instruction in either the TriCore1 3 or TriCore1 3 1 to ensure the previous CSA contents are flushed to memory In both TriCore1 3 and TriCore1 3 1 any lower context save operation BISR or SVLCX will automatically flush any cached upper context to memory before the lower context is saved CPU _TC H005 Wake up from Idle Sleep Mode A typical use case for idle or sleep mode is that software puts the CPU into one of these modes each time it has to wait for an interrupt Idle or Sleep Mode is requested by writing to the Power Management Control and Status Register PMCSR However when the write access to PMCSR is delayed e g by a higher priority bus access TriCore may enter idle or sleep mode while the interrupt which should wake up the CPU is already executed As long as no additional interrupts are triggered the CPU will endlessly stay in idle sleep mode Therefore e g the following software sequen
29. on X Effects In the described case the faulty node may not stop slot counting and may continue to transmit dynamic frames This may lead to a frame collision in the current dynamic segment Workaround None FlexRay Al 097 Loop back mode operates only at 10 MBit s Description The looped back data is falsified at the two lower baud rates of 5 and 2 5 MBit s Scope The erratum is limited to test cases where loop back is used with the baud rate prescaler PRTC1 BRP 1 0 configured to 5 or 2 5 MBit s Effects The loop back self test is only possible at the highest baud rate Workaround Run loop back tests with 10 MBit s PRTC1 BRP 1 0 00 TC1797 QS AC 68 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations FlexRay Al 099 Erroneous cycle offset during startup after abort of start up or normal operation Description An abort of startup or normal operation by a READY command near the macotick border may lead to the effect that the state INITIALIZE SCHEDULE is one macrotick too short during the first following integration attempt This leads to an early cycle start in state INTEGRATION _COLDSTART_CHECK or INTEGRATION_CONSISTENCY_CHECK As a result the integrating node calculates a cycle offset of one macrotick at the end of the first even odd cycle pair in the states INTEGRATION _COLDSTART_CHECK or INTEGRATION_CONSISTENCY_CHECK and tries to correct this offset If the node is able t
30. result that MSET PI would have generated but PRAM is unchanged ST PI Rx offsetl Rx written to PRAM so MSET PI functionality non atomic is achieved MCLR PI AND PI Ry offset2 Ry now contains result that MCLR PI would have generated but PRAM is unchanged Se BI Ry offset2 Ry written to PRAM so MCLR PI functionality non atomic is achieved TC1797 QS AC 84 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations XCH PI MOV Ry Rx cc_UC Ry used a temporary holding register LD PI Rx offset3 Rx now contains PRAM value but PRAM is unchanged ST PI Ry offset3 Ry written to PRAM so XCH PI functionality non atomic is achieved Workaround 2 Place a dummy FPI read in front of every PCP atomic PRAM instruction i e Replace MSET PI with CLR R7 0x5 prevent nested interrupt NOP LD F R4 RO size 32 dummy load addr setup required MSET PI Replace MCLR PI with CLR R7 0x5 prevent nested interrupt NOP LD F R4 RO size 32 dummy load addr setup required MCLR PI Replace XCH PI with CLR R7 0x5 prevent nested interrupt NOP LD F R4 RO size 32 dummy load addr setup required XCH PI PCP_TC 039 PCP posted error interrupt to CPU may be lost when the queue is full in 2 1 mode In the unlikely case where PCP 2 1 mode is enabled TC1797 QS AC 85 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional
31. subsist in the DMI line buffer D Cache turned off The problem occurs when the dcache is turned off When the dcache is turned off or non existent the DMI line buffer operates as a 16 byte cache Writing a one to the OVC_OCON DCINVAL register should invalidate the data inside the DMI line buffer as long as the data is not dirty This invalidation mechanism does not work on AUDO Future devices Writing to OVC_OCON DCINVAL will have no effect at all Any cache line which was previously loaded into the DMI line buffer will not be invalidated whether it was dirty or not Workaround The workaround consists in executing a cachei wi instruction with an operand register containing a random non protected cacheable address The DMI line buffer will respond to cachei wi instructions regardless of the content of its TC1797 QS AC 38 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations operand provided that the operand contains a cacheable address which is not protected On execution of cachei wi the DMI line buffer will flush and invalidate itself For example executing the following two instructions should flush and invalidate the DMI line buffer in any circumstance Note that the current workaround always invalidates the entry regardless of whether it was dirty or not movh a a0 0x8000 Cachei operand is random non protected cacheable address cachei wi a0 The DLB gets invalidated regardless of the value in
32. 1 mode In this case the outstanding store transaction executed in Supervisor mode may be transferred to the bus in User mode the bus systems do not discriminate between User 0 and User 1 modes Due to the blocking nature of load transactions and the fact that User mode code cannot modify the Psw neither of these other situations can cause a problem Example st w aX dX Store to Supervisor mode protected SFR mtcr PSW dY Modify PSW IO to switch to User mode Workaround Any MTCR instruction targeting the Psw which may change the Psw IO bit field must be preceded by a DSYNC instruction unless it can be guaranteed that no store transaction is outstanding st w aX dX Store to Supervisor mode protected SFR dsync mtcr PSW dY Modify PSW IO to switch to User mode CPU_TC 106 Incorrect PSW update for certain IP instructions dual issued with MTCR PSW In certain situations where an Integer Pipeline IP instruction which updates the PSW user status bits e g PSW V Overflow is followed immediately by an MTCR instruction targetting the Psw with the instructions being dual issued TC1797 QS AC 14 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations the update priority is incorrect In this case the Psw user status bits are updated with the value from the IP instruction rather than the later MTCR instruction This situation only occurs in 2 cases e MUL MADD MSUB instruction followed by MT
33. 15 12 insert d15 d14 d15 6 16 mov a al5 d15 load trap value of d15 from CSA ld w di5 al5 0x3Cc mov a al5 all movh a all his interuptReal lea all all los interruptReal jump to trap handler will return to interruptReal ji al5 the remaining part of the interrupt handler interruptReal Again it is preferred that this method be used immediately at the beginning of the interrupt handler since this approach works straightforwardly provided there is no state in the Upper Context registers or on the interrupt stack that is required by the interrupt handler when it returned to Although it is possible to adapt this approach to operate later during interrupt handling additional steps need to be taken to ensure the correct state is maintained when returning to the interrupt handler CPU_TC 114 CAE Trap may be generated by UPDFL instruction UPDFL is a User mode instruction implemented as part of the TriCore1 Floating Point Unit FPU which allows individual bits of the PSw user status bits PSW 31 24 to be set or cleared Contrary to early revisions of the TriCore1 3 1 architecture manual and in contrast to most other FPU instructions the UPDFL instruction should not generate Co Processor Asynchronous Error CAE traps However in certain circumstances the TriCore1 3 1 FPU will generate CAE traps for UPDFL instructions The TriCore1 3 1 FPU will generate a CAE trap upon execution of the UPDFL instruction in
34. 25 01 2011 Cafineon Errata Sheet History List Change Summary Table 4 Functional Deviations cont d Functional Short Description Cha Pa Deviation nge ge FlexRay_Al 069 Update of Aggregated Channel Status ACS 51 in dynamic segment in minislots following slot ID 2047 FlexRay_Al 070 Cycle counter MTCCV CCV is updated 51 erroneously in dedicated startup states FlexRay_Al 071 Faulty update of LDTS LDTA LDTB 10 0 52 due to parity error FlexRay_Al 072 Improper resolution of startup collision 53 FlexRay_Al 073 Switching from loop back test mode at low 53 bit rate to normal active takes longer then expected FlexRay_Al 074 Integration successful on X and 54 integration abort on Y at the same point in time leads to inconsistent states of SUC and GTU FlexRay_Al 075 Detection of parity errors outside 55 immediate scope FlexRay_Al 076 CCSV SLM 1 0 delayed to 56 CCSV POCS 5 0 on transitions between states WAKEUP and READY FlexRay_Al 077 Wakeup listen counter started one bit time 57 early FlexRay_Al 078 Payload corruption after reception of valid 57 frame followed by slot boundary crossing frame FlexRay_Al 080 CLEAR_RAMS command does not clear 58 the 1st RAM word FlexRay_Al 081 Write accesses to ERAY_NDIC and 59 TC1797 QS AC ERAY_MSIC can fail if ERAY_CLC FMC gt 2 6 115 Rel 1 4 25 01 2011 Cafineon Errata Sheet History List
35. 4 25 01 2011 Infineon Errata Sheet Functional Deviations Workaround Use at least one leading delay in order to avoid this problem SSC _AI 026 Master with highest baud rate set generates erroneous phase error If the SSC is in master mode the highest baud rate is initialized and CON PO 1 and CON PH 0 there will be a phase error on the MRST line already on the shift edge and not on the latching edge of the shift clock e Phase error already at shift edge The master runs with baud rate zero The internal clock is derived from the rising and the falling edge If the baud rate is different from zero there is a gap between these pulses of these internal generated clocks However if the baud rate is zero there is no gap which causes that the edge detection is to slow for the fast changing input signal This means that the input data is already in the first delay stage of the phase detection when the delayed shift clock reaches the condition for a phase error check Therefore the phase error signal appears Phase error pulse at the end of transmission The reason for this is the combination of point 1 and the fact that the end of the transmission is reached Thus the bit counter SSCBC reaches zero and the phase error detection will be switched off Workaround Don t use a phase error in master mode if the baud rate register is programmed to zero SSCBR 0 which means that only the fractional divider is used Or program the
36. CR Psw e RSTV instruction followed by MTCR Psw Example rstv mtcr PSW dY Modify PSW Workaround Insert one NOP instruction between the MUL MADD MSUB RSTV instruction and the MTCR instruction updating the PSW rstv nop mtcr PSW dY Modify PSW CPU_TC 107 SYSCON FCDSF may not be set after FCD Trap Under certain conditions the SYSCON FCDSF flag may not be set after an FCD trap is entered This situation may occur when the CSA Context Save Area list is located in cacheable memory or dependent upon the state of the upper context shadow registers when the CSA list is located in LDRAM The SYSCON FCDSF flag may be used by other trap handlers typically those for asynchronous traps to determine if an FCD trap handler was in progress when the another trap was taken Workaround In the case where the CSA list is statically located in memory asynchronous trap handlers may detect that an FCD trap was in progress by comparing the TC1797 QS AC 15 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations current values of FCX and LCx thus achieving similar functionality to the SYSCON FCDSF flag In the case where the CSA list is dynamically managed no reliable workaround is possible CPU_TC 108 Incorrect Data Size for Circular Addressing mode instruc tions with wrap around In certain situations where a Load or Store instruction using circular addressing mode encounters the circular buffer wrap arou
37. Cinfineon Errata Sheet Rel 1 4 25 01 2011 Device TC1797 Marking Step QS AC Package P PG BGA 416 10 01961AERRA This Errata Sheet describes the deviations from the current user documentation Table 1 Current Documentation TC1797 User s Manual V1 1 May 2009 TC1797 Data Sheet V1 2 September 2009 TriCore 1 Architecture V1 3 8 January 2008 Make sure you always use the corresponding documentation for this device User s Manual Data Sheet Documentation Addendum if applicable TriCore Architecture Manual Errata Sheet available in category Documents at www infineon com TC1797 Each erratum identifier follows the pattern Module_Arch TypeNumber e Module subsystem peripheral or function affected by the erratum Arch microcontroller architecture where the erratum was firstly detected Al Architecture Independent CIC Companion ICs TC TriCore X XC166 XE166 XC2000 Family XC8 XC800 Family none C166 Family e Type category of deviation none Functional Deviation P Parametric Deviation H Application Hint TC1797 QS AC 1 115 Rel 1 4 25 01 2011 Infineon Errata Sheet D Documentation Update e Number ascending sequential number within the three previous fields As this sequence is used over several derivatives including already solved deviations gaps inside this enumeration can occur Note Devices marked with EES or ES are engineering samples which m
38. Deviations e PCP is configured to post error interrupts to CPU e achannel is running e this channel s R7 CEN is cleared e PCP exits this channel with posting an interrupt to the CPU as a result of the posted interrupt CPU queue becomes full and the same channel is invoked again immediately with context restore optimization the current channel should exit with posting an error interrupt to CPU but actually the error interrupt to CPU is lost Workaround Application software should not clear R7 CEN if there is a chance that the channel is going to be executed again RESET TC 001 SCU_RSTSTAT PORST not set by a combined Debug System Application Reset Causing simultaneously a System Application and Debug Reset via CBS_OSTATE RSTCLO 3 in most cases does not leave the SCU_RSTSTAT PORST bit set as specified Bit SCU_RSTSTAT PORST stays set only if reset source ESRO was configured not to generate any reset SCU_RSTCON ESRO 003 If the ESRO reset source is configured to generate a reset bit SCU_RSTSTAT PORST is cleared and bit SCU_RSTSTAT ESR0O is set instead Bits CBS _OSTATE RSTCLO 3 are either set by setting bits CBS_OCNTRL OJC4 7 or CBS_OJCONF OJC4 7 Debugging of PORST only application software under debugger control is therefore not working if the ESRO reset source generates a reset Workaround Before triggering a simultaneous System Application and Debug Reset by the OCDS system bit f
39. Future family allow tool access via dedicated pins in two basic protocol modes DAP and JTAG To avoid changes to the application environment the tool selects the protocol to be used by signalling over the same pins later used for communication Default startup mode is two pin DAP Other modes JTAG or three pin DAP are selected by specific telegrams which need to be sent to the device One of the major advantages of DAP versus JTAG within a harsh automotive environment is its robustness regarding bit errors in the telegram transmission This is achieved by adding checksums CRC to all telegrams The only exception is the telegram to switch from DAP to JTAG see jtag_mode telegram as this telegram is potentially sent by legacy JTAG only tools not able to generate properly formatted DAP telegrams A method has been implemented to prevent the following safety hole If bit errors e g caused by EMC change another DAP telegram to the telegram meaning switch to JTAG mode a tool using DAP pins only would loose connection in an unrecoverable manner Therefore the DAP module can be configured by the tool via SFR CBS_OSTATE DJMODE to ignore the switch to JTAG mode also called BYPASS telegram Due to an imperfection within the design the intended protection via CBS_OSTATE DJMODE does not become effective in three pin DAP mode CBS_OSTATE DJMODE 11 Note Two pin DAP mode is not affected Workaround None for three pin DAP mode
40. If a running message buffer scan is interrupted by the NIT it cannot be guaranteed that the correct message buffer is used for transmission in slot 1 of the next cycle Workaround If cycle filtering is used assign all message buffers configured for slot 1 to the static buffers section l e message buffer number lt MRC FDB 4 0 FlexRay_Al 086 Bit IBFs of Register cusT1 always 0 Bit IBFS Input Buffer Status of register CUST1 Busy and Input Buffer Control Register is always read as 0g Therefore it is not possible to use this status bit to decide which of the two Input Buffer RAMs IBF is accessible by the host via CIF as Input Buffer Note It is ensured by hardware that bits IBF1PAG and IBF2PAG Input Buffer 1 2 Page Select of register CUST1 can only be written when the corresponding IBF is accessible Otherwise the value written to IBF1PAG or IBF2PAG is ignored Writing 1 to both bits at the same time leads to a TC1797 QS AC 62 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations correct selection of the upper page of the accessible IBF writing Op to both bits at the same time leads to a correct selection of the lower page of the accessible IBF Workaround After a write access to change the status of IBF1PAG or IBF2PAG e g the following sequence may be used to determine which IBF is currently accessible 1 read register CUST1 2 write the desired value to BF 1 PAG or IBF2PAG must be
41. Master Write access The following should be noted Atall times the DMA FPI Master and DMA FPI Slave remain accessible Ifthe LMB DMA Master is in the lock up state then accesses can still be made to the LMB bus by all other LMB Masters e g LFI LMB Master Hint Do not perform a DMA channel MLI Cerberus or DMA FPI Slave access to a reserved address all areas specified as reserved in the Memory Map Chapter LMB Address Map Table must not be accessed by the DMA ME MLI Cerberus Workaround The LMB Bus Control Unit can recognise a DMA LMB Master access to an unrecognised slave It can be programmed to raise an interrupt and then generate a Class 3 Application Reset to clear the lock up state DMI _TC 014 Problems with Parity Handling in TriCore Data Memories A small number of cases exist in which the handling of parity errors in the TriCore data memories LDRAM DCache and Data Cache Tag does not function correctly potentially leading to data corruption for accesses to these memories This data corruption may occur whether the access to one of these memories is from the TriCore CPU or in the case of LDRAM from another bus master access via the LMB Workaround In systems where the Data Memory parity handling must be enabled the following is required to guarantee correct behaviour e Compatibility mode must be selected for the TriCore Data side memories by setting COMPAT DIE 1 In this case parity errors are
42. RMAL_ACTIVE NORMAL_PASSIVE state instead of the last rate correction value calculated in NORMAL_ACTIVE state This may lead to a desynchronisation of the node although it may stay in NORMAL_ACTIVE state depending on gMaxWithoutClockCorrectionPassive and decreases the probability to re enter NORMAL_ACTIVE state if it has switched to NORMAL_PASSIVE pAllowHaltDueToclock false Workaround It is recommended to set gMaxWithoutClockCorrectionPassive to 1 If missing sync frames cause the node to enter NORMAL_PASSIVE state use higher level application software to leave this state and to initiate a re integration into the cluster HALT state can also be used instead of NORMAL_PASSIVE state by setting pAllowHaltDueToClock to true FlexRay AlI 092 Initial rate correction value of an integrating node is zero if pMicrolnitialOffsetA B 0x00 Description The initial rate correction value as calculated in figure 8 8 of protocol spec v2 1 is zero if parameter pMicrolnitialOffsetA B was configured to be zero TC1797 QS AC 64 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Scope The erratum is limited to the case where pMicrolnitialOffsetA B is configured to zero Effects Starting with an initial rate correction value of zero leads to an adjustment of the rate correction earliest 3 cycles later see figure 7 10 of protocol spec v2 1 In a worst case scenario if the whole cluster is drifting away too fast th
43. Sheet Functional Deviations Table 10 Relative erase time increments Frequency MHz Increment for P Flash Increment for D Flash 80 8 5 100 5 3 133 2 1 5 150 1 1 180 0 0 FLASH TC 035 Flash programing time out of specification As per specification flash programing time specified is per page 5msec Where as actual programing time measured on the device is per page 5 5msec FlexRay Al 056 In case eray_bclk is below eray_sclk 2 TEST1 CERA B may fail to report a detected coding error Description All detected coding errors should be reported in the Test Register 1 at TEST1 CERA CERB If eray_bclk is below eray_sclk 2 it may happen depending on phase difference of eray_bclk and eray_sclk that TEST1 CERA CERB are not updated in case of a detected coding error and remain in the state 0000 No coding error detected Scope The erratum is limited to the case where eray_bclk is below eray_sclk 2 Effects Coding errors not reported via TEST1 CERA CERB The frame decoding is not affected TC1797 QS AC 46 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Workaround None FlexRay_ Al 062 Sync frame reception after noise or aborted frame before action point Description In case noise or an aborted frame leads to the detection of a secondary time reference point STRP and after this a valid sync frame i
44. a0 If the user is not concerned in invalidating the DMI line buffer but simply guaranteeing its coherency with external memory then there is another simple workaround This consists in issueing a read to a dummy cacheable address pointing outside the 16 byte block containing the next required data Access to the next required data will then necessarily result in a refill and the resulting data will be coherent This is what the following code does a0 contains a dummy address and a1 contains the address for the user s required data movh a a0 0x8000 Dummy address is 0x80000000 ld w d0 a0 7 a0 has to point to different 16 byte block than al ld w d0 al This load will b xecuted fresh from memory with a refill 7 Read data will be coherent with rest of memory EBU _TC 020 BAA Delay Options Controlled by Wrong Register Field The timing options for the BAA signal are specified as being controlled by the settings of the BUSRCONx EXTCLOCK and BUSRCONx EBSE register fields In the implementation of the EBU the logic controlling BAA timing was connected to the BUSRCONx ECSE field instead of BUSRCONx EBSE TC1797 QS AC 39 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Workaround Use the BUSRCONx ECSE field to control the desired timing option for the BAA signal EBU_TC 021 Incorrect delay calculation accessing Asynchronous mem ories
45. able clock is present at the oscillator input pin XTAL1 after PORST the device will wait indefinitely i e it hangs and is not able to execute application code or enter one of the bootstrap loader modes This behavior occurs only after PORST during initialization of the FlexRay module by the internal Startup Software Workaround Proper device start up after PORST is only possible if a stable clock signal from an external crystal ceramic resonator or an external clock source is to available at the XTAL1 pin of the device CPU_TC 105 User Supervisor mode not staged correctly for Store In structions Bus transactions initiated by TriCore load or store instructions have a number of associated attributes such as address data size etc derived from the load or store instruction itself In addition bus transactions also have an IO privilege level status flag User Supervisor mode derived from the PSW 1IO bit field TC1797 QS AC 13 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Unlike attributes derived from the instruction the User Supervisor mode status of TriCore initiated bus transactions is not staged correctly in the TriCore pipeline and is derived directly from the PSW IO bit field This issue can only cause a problem in certain circumstances specifically when a store transaction is outstanding e g held in the CPU store buffer and the PSW is modified to switch from Supervisor to User 0 or User
46. ait for activity TEST1 AOx 1 gt bus not idle e set Test Multiplexer Control back to Normal signal path TEST1 TMC 0 e wait for no activity TEST1 AOx 0 gt bus idle Now the next transmission can be requested FlexRay AI H005 Initialization of internal RAMs requires one eray_bclk cycle more The initialization of the E Ray internal RAMs as started after hardware reset or by CHI command CLEAR_RAMS SUCC1 CMD 3 0 1100 takes 2049 eray_bclk cycles instead of 2048 eray_bclk cycles as described in the E Ray Specification TC1797 QS AC 98 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints Signalling of the end of the RAM initialization sequence by transition of MHDS CRAM from 1 to Op is correct FlexRay AI H006 Transmission in ATM Loopback mode When operating the E Ray in ATM Loopback mode there should be only one transmission active at the same time Requesting two or more transmissions in parallel is not allowed To avoid problems a new transmission request should only be issued when the previously requested transmission has finished This can be done by checking registers TXRQ1 2 3 4 for pending transmission requests FlexRay AI H007 Reporting of coding errors via TEST1 CERA B When the protocol engine receives a frame that contains a frame CRC error as well as an FES decoding error it will report the FES decoding error instead of the CRC error which should have precedence accordi
47. anslation and a conflict cannot be ruled out In other systems no MMU MMU disabled conflict detection is performed on the complete address Example Case 1 LDA al2 0xD0001008 Circular Buffer Base LDA al3 0x00180016 Circular Buffer Limit and Index st b a12 0x1 d2 Store to byte offset 0x9 ld w d6 al2 al3 c Circular Buffer wrap 16 16 In this example the circular buffer base address is double word but not quad word aligned The byte store to address 0xD0001009 is immediately followed by a load operation and is placed in the CPU store buffer The word load instruction encounters the circular buffer wrap condition and is split into 2 half word accesses to the top 0xD0001016 and bottom 0xD0001008 of the circular buffer The first load access completes correctly but due to the bug the second access overtakes the store operation and returns the previous half word from 0xD0001008 Example Case 2 LDA al2 0xD0001000 Circular Buffer Base LDA al3 0x00140012 Circular Buffer Limit and Index st b a12 0x1 d2 Store to byte offset 0x1 ld w d6 al2 al3 c Circular Buffer wrap 16 16 In this example the circular buffer base address is quad word aligned but the buffer size is an odd number of words 0x14 5 words The byte store to address 0xD0001001 is immediately followed by a load operation and is placed TC1797 QS AC 21 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations
48. around No workaround possible Choose source IOADDR and destination ICTTA addresses in word wide areas only OCDS _TC 015 IOCONF register bits affected by Application Reset The IOCONF register is erroneously cleared by each Application Reset Therefore Communication Mode is entered whenever the TriCore is reset As the interaction with the tool is suspended anyway due to Error State of the lOClient no immediate damage is done To resume interaction after leaving the Error State IO_SUPERVISOR instruction however the required mode must be restored by rewriting the IOCOMF register IO_CONFIG instruction Workaround After detecting an Application Reset IOINFO BUS RST set the IOCONF register should be rewritten by the tool after the Error State is left TC1797 QS AC 73 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations OCDS_TC 016 Triggered Transfer dirty bit repeated by IO_READ_TRIG The dirty bit appended to the data of an IO_READ_WORD instruction during Triggered Transfer mode indicates that there was at least one extra trigger event missed prior to capturing the transmitted data The dirty bit is therefore cleared after each IO READ_ WORD A consecutive IO READ_TRIG instruction however will erroneously undo the clear The next IO_READ_WORD will then again see a set dirty bit even if no trigger was missed Workaround Do not issue an IO_READ_TRIG instruction after an IO READ_ WORD returned a s
49. at the instruction immediately following the RFM be submitted to inadequate protection rules as defined by the old PSW PRS field e Problem sequence e instr monitor e instr monitor e instr monitor e RFM monitor e Instruction Uses debug monitor s PSW PRS field as opposed to newly restored one e instruction2 Workaround To fix this the user needs to do the following before exiting the monitor using RFM e gt Retrieve the old value of PSW from location DCX 4 gt Do a MFCR and a MTCR to copy the old value of PSW PRS into PSW without changing other PSW fields e gt DSYNC e gt RFM This sequence will guarantee that all instructions fetched subsequently to the RFM will be submitted to the new PSW PRS field TC1797 QS AC 78 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations OCDS_TC 027 BAM breakpoints with associated halt action can poten tially corrupt the PC BAM breakpoints can be programmed to trigger a halt action When such a breakpoint is taken the CPU will go into HALT mode immediately after the instruction is executed This mechanism is broken in the case of conditional jumps When a BAM breakpoint with halt action is triggered on a conditional jump the PC for the next instruction will potentially be corrupted before the CPU goes into HALT mode On exiting HALT mode the CPU will see the corrupted value of the PC and hence resume code execution from an erroneous locatio
50. ay not be completely tested in all functional and electrical characteristics therefore they should be used for evaluation only Note This device is equipped with a TriCore TC1 3 1 Core Some of the errata have workarounds which are possibly supported by the tool vendors Some corresponding compiler switches need possibly to be set Please see the respective documentation of your compiler For effects of issues related to the on chip debug system see also the documentation of the debug tool vendor The specific test conditions for EES and ES are documented in a separate Status Sheet TC1797 QS AC 2 115 Rel 1 4 25 01 2011 Cafineon Errata Sheet History List Change Summary 1 History List Change Summary Table 2 History List Version Date Remark 1 0 22 09 2008 1 1 04 12 2008 1 2 01 07 2009 Updated Documentation Reference TC1797 User s Manual V1 1 2009 05 TC1797 Data Sheet V1 1 2009 04 Removed BROM_TC H001 Frequency RatiofSYS fOSC 2 for Bootstrap Loaders see p 7 4 in TC1797 User s Manual V1 1 1 3 18 12 2009 Updated Documentation Reference TC1797 Data Sheet V1 2 2009 09 Removed FLASH_TC 036 DFLASH Margin Control Register MARD updated description see p 5 69 in TC1797 User s Manual V1 1 1 4 25 01 2011 Note Changes to the previous errata sheet version are particularly marked in column Change in the following tables Table 3 Errata fixed in thi
51. bled not yet Active state by a control signal restart driven by the on chip debug logic e g CBS_OSTATE and actuated by higher level on chip tool firmware In the current design this feature is implemented as synchronous reset i e it requires clock edges inside the DAP module to work properly As DAPO is the TC1797 QS AC 71 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations only clock source used by DAP the reset is not sensed if DAPO is not toggled by the host at least once while restart is asserted Workaround There is no workaround available Attention Do not assert restart for longer periods of time unless the interface shall be functionally locked The bug fixed version of future devices will also reset DAP as long as restart is asserted but will additionally store the rising edge until at least two DAPO clock edges have been seen OCDS_AlI 002 JTAG Instruction must be 8 bit long The JTAG TAP controller implemented in all Infineon devices strictly adheres to the standard IEEE 1149 1 2001 One side effect of this standard requires special awareness as it can cause severe errors Upon entry to the Capture IR state the internal shift register is preloaded with a constant namely 01 In the Shift IR state the bits from the host are prepended i e for each incoming bit the old LSB is dropped the remaining 7 bits are shifted right one bit position and the incoming bit becomes
52. ce is recommended for user mode 1 supervisor mode _disable disable interrupts TC1797 QS AC 94 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints do SCU_PMCSR 0x1 request idle mode if SCU_PMCSR ensure PMCSR is written _enable after wake up enable interrupts _nop _nop ensure interrupts are enabled _disable after service disable interrupts while condition return to idle mode depending on condition set by interrupt handler _enable EBU TC H005 Potential live lock situation on concurrent CPU and PCP accesses to external memories If a master CPU PCP DMA is already accessing an external memory every later access from another master will be retried on hardware level Under very improbable timing conditions it may lead to a live lock scenario for example e PCP polling continuously for a semaphore on an external memory e CPU executing code from external memory in order to release the semaphore e The CPU may never get access to the EBU if the PCP access started before Workaround In case that several masters have access to the EBU the application software has to reserve time windows for each of the masters whose duration depends on the latency constraints of the application EBU_TC H008 Use of EBU standby mode EBU standby mode is enabled by writing 1 to the EBU_CLC DISR field default value after reset 0 TC1797 QS AC
53. code are mandatory to ensure that reads from the GPRs target the register file directly rather than the forwarding paths which always function correctly Secondly within the FCU trap handler itself only the global and lower context registers may be used D0 D7 and AO A9 Since the upper context information is already lost in an FCU trap condition usage of the global and lower context registers without previously saving this information is acceptable CPU_TC 111 Imprecise Return Address for FCU Trap The FCU trap is taken when a context save operation is attempted but the free context list is found to be empty or when an error is encountered during a context save or restore operation In failing to complete the context operation architectural state is lost so the occurrence of an FCU trap is a non recoverable system error Since FCU traps are non recoverable system errors having a precise return address is not important but can be useful in establishing the cause of the FCU trap The TriCore1 CPU does not generate a precise return address for an FCU trap if the cause of the FCU trap was one of the following trap types FCD DAE DIE CAE or NMI In each of these circumstances the return address may be invalid Workaround None TC1797 QS AC 24 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations CPU _TC 113 Interrupt may be taken during Trap entry sequence A problem exists whereby interrupts are not corre
54. ctly disabled at the very beginning of a trap entry sequence and under certain circumstances an interrupt may be taken at the start of a trap handler The problem occurs when an interrupt request is received by the TriCore CPU within a window spanning a single clock cycle either side of a trap condition being detected and where interrupts are enabled and the interrupt priority number is higher than the current CPU priority number CCPN In this case the trap entry sequence begins and the upper context registers are stored to the appropriate CSA However before the first instruction of the trap handler is executed the interrupt condition is detected and the interrupt handler entered at a time when interrupts should be disabled This problem affects all trap types but does not affect interrupts an interrupt cannot be taken during the entry sequence of another interrupt It should be noted that no state information is lost when this issue occurs When the interrupt handler completes and the RFE instruction is executed program execution restarts with the first instruction of the interrupted trap handler and the trap handler then continues as normal The main issue associated with this problem is that the handling of the interrupt will delay the start of the trap handler For the majority of trap types associated with the program flow this is not a problem However where the interrupted trap type denotes a serious system problem such as an NMI trap
55. ctrical and Timing Specification AC DC ADC Short Description Cha Pa Deviation nge ge DTS_TC P001 Test Conditions for Sensor Accuracy Trsa 90 FADC_TC P003 Incorrect test condition specified in 90 datasheet for FADC parameter Input leakage current at Veacnp MSC_TC P001 Incorrect Vos limits for LVDS pads New 90 specified in Data Sheet PLL_TC P005 PLL Parameters for fyco gt 780 MHz 91 Table 6 Application Hints Hint Short Description Cha Pa nge ge ADC_AI H002 Minimizing Power Consumption of an 92 ADC Module CPU_TC H004 PCXI Handling Differences in 92 TriCore1 3 1 CPU_TC H005 Wake up from Idle Sleep Mode New 94 EBU_TC H005 Potential live lock situation on 95 concurrent CPU and PCP accesses to external memories EBU_TC H008 Use of EBU standby mode 95 EBU_TC H009 Legal Parameters Allow an Invalid Page 96 Mode Access to be Configured FIRM_TC H000 Reading the Flash Microcode Version 97 FlexRay_Al H002 Timer 1 Precision 97 FlexRay_AlI H003 Select upper lower page for IBF1 IBF2 in 97 RAM test mode TC1797 QS AC 10 115 Rel 1 4 25 01 2011 Cafineon Errata Sheet History List Change Summary Table 6 Application Hints cont d Hint Short Description Cha Pa nge ge FlexRay_Al H004 Only the first message can be received in 98 External Loop Back mode FlexRay_Al H005 Initialization of inter
56. d recoverable but are time sensitive and need to be executed immediately then some method of deferring the interrupt processing is required If the test of the situation e g checking the PCXI PIE bit is clear is at the start of the Interrupt handler then there are two simple methods to consider The first method would be to re request the interrupt by writing the appropriate Service Request Control Register with the SETR bit set to one and then executing an RFE which will be taken back to the trap handler The interrupt will now be pending again but will not be taken until the trap handler executes its RFE to re enable interrupts This method is simple if the device and hence it s SRC register address generating the interrupt is known If this is not easy to determine statically or dynamically the second method might be preferred The second method would be to jump to the trap handler after setting the trap identification number TIN and the return address which the trap handler will use to be the next instruction in the interrupt handler This relies on the fact that the CSA saved away by the preemption of the trap handler is equally valid as an execution context for the interrupt handler The code for this method is as follows interruptN mfcr di5 PCXI jnz t dl5 23 interruptReal TC1797 QS AC 27 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations force CSA into memory dsync sh h d14 d
57. duct intent system FPI errors are extremely unlikely and no workaround is required For debugging purposes it may be useful to prevent these issues by not allowing any pending FPI write PCP_FTD FPWC 103 although this action may impact PCP performance Register PCP _FTD address is F004 3F30 field FPWC is bits 6 5 1 Register PCP_FTD is not documented in the Target Specification User s Manual Its symbolic name may therefore not be supported by all versions of tools compiler debugger etc TC1797 QS AC 83 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Note FPI errors are extremely unlikely and in any case are an indication of system malfunction In such situation the recommended procedure is to restart the system PCP _TC 038 PCP atomic PRAM operations may operate incorrectly PCP atomic PRAM instructions XCH PI MSET PI MCLR PI may operate incorrectly when the read part coincides with the write part of an FPI read modify write operation to PRAM Workaround 1 If atomicity is required for the application replace all atomic PRAM instructions with FPI RMW instructions XCH F SET F CLR F If atomicity is not required either ensure that no FPI master including PCP itself issues an FPI RMW operation on PRAM or replace all MSET PI MCLR PI and XCH PI with their non atomic equivalents Equivalent non atomic instructions MSET PI OR PI Rx offsetl Rx now contains
58. e integrating node would not be able to follow and therefore abort integration Workaround Avoid configurations with pMicrolnitialOffsetA B equal to zero If the related configuration constraint of the protocol specification results in pMicrolnitialOffsetA B equal to zero configure it to one instead This will lead to a correct initial rate correction value it will delay the startup of the node by only one microtick FlexRay Al 093 Acceptance of startup frames received after reception of more than gSyncNodeMax sync frames Description If a node receives in an even cycle a startup frame after it has received more than gSyncNodeMax sync frames this startup frame is added erroneously by process CSP to the number of valid startup frames zStartupNodes The faulty number of startup frames is delivered to the process POC As a consequence this node may integrate erroneously to the running cluster because it assumes that it has received the required number of startup frames Scope The erratum is limited to the case of more than gSyncNodeMax sync frames Effects TC1797 QS AC 65 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations In the described case a node may erroneously integrate successfully into a running cluster Workaround Use frame schedules where all startup frames are placed in the first static slots gSyncNodeMax should be configured to be greater than or equal to the number of sync frames in
59. e 81 TC1797 QS AC atomic PRAM instructions 8 115 Rel 1 4 25 01 2011 Infineon Errata Sheet History List Change Summary Table 4 Functional Deviations cont d Functional Short Description Cha Pa Deviation nge ge PCP_TC 032 Incorrect PCP behaviour following FPI 82 timeouts as a slave PCP_TC 034 Usage of R7 requires delays between 82 operations PCP_TC 035 Atomic PRAM operation right after 83 COPY BCOPY PCP_TC 036 Unexpected behaviour after failed posted 83 FPI write PCP_TC 038 PCP atomic PRAM operations may operate Upd 84 incorrectly ate PCP_TC 039 PCP posted error interrupt to CPU may be 85 lost when the queue is full in 2 1 mode RESET_TC 001 SCU_RSTSTAT PORST not set by a 86 combined Debug System Application Reset SCU_TC 016 Reset Value of Registers ESRCFG0 1 87 SSC_AI 022 Phase error detection switched off too 87 early at the end of a transmission SSC_AI 023 Clock phase control causes failing data 88 transmission in slave mode SSC_AI 024 SLSO output gets stuck if a reconfig from 88 slave to master mode happens SSC_AI 025 First shift clock period will be one PLL 88 clock too short because not syncronized to baudrate SSC_AI 026 Master with highest baud rate set 89 generates erroneous phase error TC1797 QS AC 9 115 Rel 1 4 25 01 2011 Infineon Errata Sheet History List Change Summary Table 5 Deviations from Ele
60. e STT mode In this case MOFCRn STT shall be 0 MultiCAN_TC H004 Double remote request Assume the following scenario A first remote frame dedicated to a message object has been received It performs a transmit setup TXRQ is set with clearing NEWDAT MultiCAN starts to send the receiver message object data frame but loses arbitration against a second remote request received by the same message object as the first one NEWDAT will be set When the appropriate message object data frame triggered by the first remote frame wins the arbitration it will be sent out and NEWDAT is not reset This leads to an additional data frame that will be sent by this message object clearing NEWDAT TC1797 QS AC 107 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints There will however not be more data frames than there are corresponding remote requests remote remote CAN Bus request date data request loss of arbitration a2 Ise u data SAT data MultiC AN PCP object P object E i y R clear clear set clear NEWDAT NEWDAT NEWDAT by HW by HW by HW Figure 3 Loss of Arbitration OCDS_TC H001 IOADDR may increment after aborted IO_READ_BLOCK If an IO_READ_BLOCK instruction is aborted by the host switching the TAP controller to the update DR state before enough data bits have been shifted out it may happen under certain clock ratios tha
61. e next instruction intended to be single stepped is executed Subsequent single step operations may be implemented using any appropriate method since interrupts will be disabled before Halt mode is entered TC1797 QS AC 30 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations If the debugger action is to re start normal execution the interrupt enable status should be restored from the value read upon hitting the initial breakpoint and the CPU re started CPU _TC 117 Cached Store Data Lost on Data Cache Invalidate via Over lay Cached store data can be lost if the overlay system requests a data cache invalidate in the same cycle as a cache line is being written The overlay control provides a mechanism to do a single cycle invalidate of all valid clean lines in the data cache by writing the OCON DCINVAL bit Please note that there is no problem if the data cache is used exclusively for read data e g flash constants Cache line state transition on DCINVAL valid clean gt DCINVAL gt invalid clean A normal store operation transitions the cache line to a valid dirty state Cache line state transition on normal store operation valid clean gt write gt valid dirty invalid clean gt write gt valid dirty In the case where the write and invalidate are received in the same cycle the dirty bit is correctly updated but the valid bit is incorrectly cleared Cache line state transition on store
62. e stage and would generate an FCU trap due to the invalid FCX pointer e Instruction in the Load Store pipeline execute stage encounters a synchronous trap condition VAF D VAP D MPR MPW MPP MPN ALN MEM DSE SOVF OVF which would also be converted into an FCU trap Workaround The LCX Free Context List Limit pointer should be initialised in order to trap impending context list overflow before the FCU condition is encountered However in order to maintain some system function in the case of an FCU trap the following workaround is required split into two parts Firstly the Context Management Class 3 trap handler must be modified to discriminate FCU traps that incorrectly appear to have a TIN pertaining to another Class 3 trap due to the bug This is done by checking for the correct behaviour of the upper context registers and jumping to the FCU trap handler if the register file behaviour is found to be in error _Class3 handler mov dl12 7 nop nop jne dl2 7 _fcu handler mov dl2 8 nop TC1797 QS AC 23 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations nop jne dl2 8 _fcu handler Now read valid D15 to obtain TIN Since the initial contents of the upper context registers are unknown it is necessary to check one of the upper context registers twice with different values in case the initial contents match the first value to be checked Note The NOP instructions in the above
63. ed by lt INSTR gt reading from R7 then the second instruction will fail providing wrong data The write will be anyway successful Workaround Add a NOP between a write to R7 followed by a read from R7 TC1797 QS AC 82 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations PCP _TC 035 Atomic PRAM operation right after COPY BCOPY The COPY BCOPY instructions have an outer loop defined by R6 CNT1 Transfer Count enabled if CNC 10 If the instruction which follows the COPY BCOPY is an atomic PRAM operation and the PCP channel is interrupted while in the COPY BCOPY outer loop the COPY BCOPY operation will not be completed successfully Workaround Do not allow atomic PRAM operations directly following COPY BCOPY In case both operations are necessarily consecutive insert a NOP in between PCP _TC 036 Unexpected behaviour after failed posted FPI write If PCP posts an FPI write including those in atomic FPI operations which produces an FPI error following malfunctions may be observed e The PCP may lock the FPI bus e Improper PCP instruction execution may occur e PRAM content corruption A subsequent COPY operation could write incorrect data e A subsequent invalid BCOPY i e a BCOPY instruction which will also generate an FPI error could cause the next channel to perform an unexpected error exit A byte or half word COPY in the next channel may write incorrect data Workaround In a pro
64. elay respectively Alternatively bit BSY may be polled and the Transmit Buffer may be written after a waiting time corresponding to 1 SCLK cycle after BSy has returned to 0p After reset the Transmit Buffer may be written at any time SSC_AI H003 Transmit Buffer Update in Slave Mode during Transmission After reset data written to the Transmit Buffer register TB are directly copied into the shift register Further data written to TB are stored in the Transmit Buffer while the shift register is not yet empty i e transmission has not yet started or is in progress If the Transmit Buffer is written in slave mode during the first phase of the shift clock SCLK supplied by the master the contents of the shift register are overwritten with the data written to TB and the first bit currently transmitted on line MRST may be corrupted No Transmit Error is detected in this case TC1797 QS AC 114 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints It is therefore recommended to update the Transmit Buffer in slave mode after the transmit interrupt TIR has been generated i e after the first SCLK phase After reset the Transmit Buffer may be written at any time SSC_TC H003 Handling of Flag STAT BSy in Master Mode In register STAT of the High Speed Synchronous Serial Interface SSC some flags have been made available that reflect module status information e g error busy closely coupled to internal state transitio
65. et Functional Deviations SSC _AI 023 Clock phase control causes failing data transmission in slave mode If SSC_CON PH 1 and no leading delay is issued by the master the data output of the slave will be corrupted The reason is that the chip select of the master enables the data output of the slave As long as the chip is inactive the slave data output is also inactive Workaround A leading delay should be used by the master A second possibility would be to initialize the first bit to be sent to the same value as the content of PISEL STIP SSC _AI 024 SLSO output gets stuck if a reconfig from slave to master mode happens The slave select output SLSO gets stuck if the SSC will be re configured from slave to master mode The SLSO will not be deactivated and therefore not correct for the 1st transmission in master mode After this 1st transmission the chip select will be deactivated and working correctly for the following transmissions Workaround Ignore the 1st data transmission of the SSC when changed from slave to master mode SSC_AI 025 First shift clock period will be one PLL clock too short be cause not syncronized to baudrate The first shift clock signal duration of the master is one PLL clock cycle shorter than it should be after a new transmit request happens at the end of the previous transmission In this case the previous transmission had a trailing delay and an inactive delay TC1797 QS AC 88 115 Rel 1
66. et dirty bit OCDS _TC 018 Startup to Bypass Mode requires more than five clocks with TMS 1 If the DAP state machine is brought to Enabled state by Power On Reset the TAP controller is fed 0 bits on its TMS input When the special sequence for Startup in Bypass Mode is detected by DAP the TAP controller already has left the Test Logic Reset state Workaround Shifting in more than five 1 bits recommendation 10 will securely bring the TAP state machine back to Test Logic Reset OCDS_TC 020 ICTTA not used by Triggered Transfer to External Address In Triggered Transfer to External Address Mode bits 24 0 of the target address are fixed to the reset value of ICTTA Only the most significant byte can by changed by O_SET_TRADDR or by writing to ICTTA Note This is the behavior of the Cerberus implemented prior to AudoNG It is therefore not possible to use Cerberus as DMA work alike to move trace data to the outside world via an interface like ASC TC1797 QS AC 74 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Workaround No workaround in Triggered Transfer to External Address mode possible only the fixed address xx10F068 can be used In Internal Mode however ICTTA is working as specified so for certain use cases the intended DMA functionality can be activated by a code snippet executed by the TriCore or PCP as long as the Debug Interface is not needed concurrently
67. ets HALT Mode e 2 LS based branch loop instruction e 3 LS based branch loop is mispredicted but resolution is overridden by HALT Workaround External agents should halt the CPU using the BRKIN pin instead of using CPS injected writes to the CSFR register Alternatively the CPU can always be halted by using the debug breakpoints Any user software write to the DBGSR CSFR should be followed by a dsync OCDS_TC 026 PSW PRS updated too late after a RFM instruction When a breakpoint with an associated TRAP action occurs the Tricore will enter a special trap called a debug monitor The RFM instruction return from TC1797 QS AC 77 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations monitor is used to return from the debug monitor trap After the RFM the CPU should resume execution at the point where it left it when the breakpoint happened On execution of the RFM instruction a light weight debug context is restored and the PSW CSFR is loaded with its new value The updated value of the PSW PRS field should then be used to select the appropriate protection register set for all subsequently fetched instructions Because PSW PRS can be updated too late after an RFM instruction the instruction following an RFM potentially sees the old value of the PSW PRS field as opposed to the new one This can be problematic since the PSW PRS field is crucial in terms of code protection and debug Indeed there is a possibility th
68. etween WAKEUP and READY the content of register CCSV may show a slight discontinuity i e CCSV SLM 1 0 may be updated late Scope The erratum is limited to configurations with SUCC1 TSM Og ALL Slot Mode Effects None CCSV SLM 1 0 only relevant in POC states NORMAL_ACTIVE and NORMAL_PASSIVE Workaround Ignore CCSV SLM 1 0 in states READY and WAKEUP TC1797 QS AC 56 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations FlexRay Al 077 Wakeup listen counter started one bit time early Description If the protocol engine is in the state WAKEUP_LISTEN and if the parameter gdWakeupSymbolRxLow is programmed to a value 11 n then the channel idle recognition CHIRP comes n bit times early Scope The erratum is limited to configurations with gdWakeupSymbolRxLow lt 11 Bit rates of 10 5 2 5 MBit s requires a minimum gdWakeupSymbolRxLow of 46 23 11 gdBit Effects The wakeup pattern is transmitted n bit times early Workaround Set gdWakeupSymbolRxLow to value gt 11 FlexRay Al 078 Payload corruption after reception of valid frame fol lowed by slot boundary crossing frame Description If after reception of a valid frame in slot N the reception of a second frame transmitted by a miss synchronized node starts in the same slot and the payload of the second frame is stored into the TBF shortly after the slot boundary the first 32 bit payload data of the first received frame in the TBF i
69. f simultaneous generation of internal signals integration successful on X on one channel and integration abort Y on the other channel Effects In the described cases the E Ray either is stuck in startup states or extends the startup by at least two cycles Workaround Use a timer to measure how long the E Ray stays in state INTEGRATION_COLDSTART_CHECK or INTEGRATION_CONSISTENCY_CHECK If the timeout is reached re enter the startup state by using the CHI commands READY and RUN FlexRay_Al 075 Detection of parity errors outside immediate scope Description The protocol engine reads at least the first two words of its Transient Buffer and one word more than required by the payload count for each transmitted message even if no data is needed null frame or payload count is zero If a TC1797 QS AC 55 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations parity error is detected when the protocol engine reads from the Transient Buffer the transmitted message is invalidated by setting its CRC code to zero Scope The erratum is limited to the case where a parity error occurs in one of the words in the Transient Buffer that are read but not needed for a particular message Effects The transmitted message is invalidated Workaround None FlexRay Al 076 ccsv s M 1 0 delayed to ccSv PocS 5 0 on tran sitions between states WAKEUP and READY Description When the POC state changes b
70. fer The problem occurs in the following situation TC1797 QS AC 19 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations The CPU store buffer contains a byte store instruction st b targeting the base address 0x1 of a circular buffer A word load instruction Id w is executed using circular addressing mode targetting the same circular buffer as the buffered byte store This word load is only half word aligned and encounters the circular buffer wrap around condition such that the second wrapped access of the load instruction to the bottom of the circular buffer targets the same address as the byte store held in the store buffer Additionally one of the following further conditions must also be present for the problem to occur The circular buffer base address for the word load is double word but not quad word 128 bit aligned i e the base address has bits 3 0 0x8 with the conflicting byte store having address bits 3 0 0x9 OR The circular buffer base address for the word load is quad word 128 bit aligned and the circular buffer size is an odd number of words i e the base address has bits 3 0 0x0 with the conflicting byte store having address bits 3 0 0x1 In these very specific circumstances the conflict between the load instruction and store buffer contents is not detected and the load instruction overtakes the store returning the data value prior to the store operation Note
71. flict condition with the contents of the CPU store buffer Again in this case the first access of the load instruction using circular addressing mode may incorrectly use the transfer data size from the second part of the multi access load instruction Since half word load instructions must be half word aligned and lId a instructions must be word aligned they cannot trigger the circular buffer wrap around condition As such this case only affects the following instructions using circular addressing mode Id w Id d Id da TC1797 QS AC 17 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Note Functional Deviations In the current TriCore1 CPU implementation load accesses are initiated from the DEC pipeline stage whilst store accesses are initiated from the following EXE pipeline stage To avoid memory port contention problems when a load follows a store instruction the CPU contains a single store buffer In the case where a store instruction in EXE is immediately followed by a load instruction in DEC the store is directed to the CPU store buffer and the load operation overtakes the store The store is then committed to memory from the store buffer on the next store instruction or non memory access cycle The store buffer is only used for store accesses to local memories LDRAM or DCache Store instructions to bus based memories are always executed immediately in order A store buffer conflict is detected when a load instruc
72. ground and a background bank In normal operation read and write accesses to the upper context registers target the same bank with read and write accesses targetting different banks just during upper context save and restore operations However in a certain corner case where an FCU trap is taken read and write accesses to the register banks remain out of synchronisation in the FCU trap handler and cannot be easily re synchronised Since FCU traps are non TC1797 QS AC 22 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations recoverable system errors with some system state already lost maintaining correct behaviour is not critical However due to the bug it is no longer straight forward to discriminate FCU traps from other context management Class 3 traps Since the read and write pointers to the register banks are incorrect in the bug situation the update of D15 with the Trap Identification Number TIN will write to one bank whilst the read of D15 in the trap handler will read the other incorrect bank returning an invalid TIN For similar reasons the upper context GPRs are unusable in an FCU trap handler since register read and write operations may target different banks The problem occurs in the following situation FCX Free Context Pointer points to an invalid location Null End of CSA list Invalid Segment Virtual or Peripheral segment e CALL CALLA CALLI instruction is in the decode pipelin
73. he erratum is limited to cluster wakeup with disturbances on a channel Effects Detection of WUP is independent of WakeupSymbolRxWindow s phase Workaround None FlexRay Al 083 Irregular sync frame list exported in state Coldstart_Gap Description If the protocol engine is in the state Coldstart_Gap it stops transmitting its own startup frame according to the protocol specification but the status data exported to the CHI SFS OSIDn register lists its own startup frame as transmitted Scope The erratum is limited to leading coldstart nodes Effects Misleading status data TC1797 QS AC 60 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Workaround Ignore misleading status data in state Coldstart_Gap FlexRay Al 084 Corruption of frame received in slot N by second frame reception before action point Description If a receive slot N is followed by a transmit slot N 1 and if between end of frame reception in slot N and start of frame transmission in slot N 1 the reception of a frame transmitted by a mis synchronized node is started it may happen that header and or payload of the valid frame received in slot N is corrupted Case1 Frame reception completed in slot N Case2 Frame reception across slot boundary between slot N and slot N 1 Case3 Frame reception starts in slot N 1 Scope The erratum is limited to the case where a receive slot is followed by a transmit slot and
74. hich make a more intensive use of the loop instruction Workaround The workaround consists in preventing all FPI agents from accessing the OxF7E10000 OxF7E1FFFF region when the CPU is not halted TC1797 QS AC 80 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations This means that the CPU CSFR and GPR registers can t be accessed on the fly whilst the CPU is running This is particularly relevant for debug tool providers who may be polling those registers as the application is running Note that accessing FPI addresses outside of the OxF7E10000 OxF7E1FFFF region will not cause the problem to happen An Application Note for tool partners describing an alternative more complex workaround for register access within the critical region by an external tool is available from Infineon PCP _TC 023 JUMP sometimes takes an extra cycle Following a taken JUMP the main state machine may misleadingly take an additional cycle of pause This occurs if the already prefetched next or second next instruction after the JUMP is one of the following instructions e LD P e STP DEBUG Any instruction with extension PI This does not cause any different program flow or incorrect result it just adds an extra dead cycle Workaround None PCP _TC 027 Longer delay when clearing R7 IEN before atomic PRAM in structions User Manual states that when clearing R7 IEN a delay of one instruction before the
75. ication by Application 110 Software PCP_TC H004 Invalid parity error generated by FPI write 110 to PRAM PCP_TC H005 Unexpected parity errors when address 0 111 of CMEM is faulty PCP_TC H006 BCOPY address alignment error may 111 affect next channel FPI operation PCP_TC H007 Do not use priority 0 to post interrupt to 111 CPU PORTS_TC H004 Using LVDS Ports in CMOS Mode 112 PORTS_TC H005_ Pad Input Registers do not capture 112 Boundary Scan data when BSD mode signal is set to high PWR_TC H005 Current Peak on Vppp during Power up 112 SSC_AI H001 Transmit Buffer Update in Slave Mode 113 after Transmission SSC_AI H002 Transmit Buffer Update in Master Mode 114 during Trailing or Inactive Delay Phase SSC_AI H003 Transmit Buffer Update in Slave Mode 114 during Transmission SSC_TC H003 Handling of Flag STAT BSY in Master 115 Mode TC1797 QS AC 12 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations 2 Functional Deviations BCU _TC 006 Polarity of Bit SvM in Register ECON The polarity of bit svm State of FPI Bus Supervisor Mode Signal in the SBCU Error Control Capture register SBCU_ECON is inverted compared to its description in the User s Manual Actually it is implemented as follows e SVM O Transfer was initiated in user modes e SVM 1 Transfer was initiated in supervisor mode BROM_TC 005 Power on reset PORST while no external clock is avail able In case no st
76. ide the same information to application software running on the device When reusing software for another device family the algorithm had to be adapted To worsen things using the wrong algorithm may cause fatal errors e g traps when accessing illegal addresses Starting with the Audo Future family the JTAG ID as available as a standard SFR CBS_JTAGID at a fixed address namely in the address space of the main Cerberus The value found in this register unambiguously defines where additional information e g CHIPID can be found in the device on hand Older devices obviously do not have the CBS _JTAGID so accessing its address may cause problems Workaround Each Cerberus module ever implemented has a version number mapped into a register CBS_JDPID at a fixed address 0xF0000408 Note This register is not published in all user manual versions e If the version number found in this register CBS_JDPID 7 0 is less than 0x50 no CBS_JTAGID register is provided The original software algorithm shall be employed by the reused software e If the version number found in this register CBS_JDPID 7 0 is 0x50 or higher the content of the CBS_JTAGID register shall be used to select the proper algorithm PCP_TC H004 Invalid parity error generated by FPI write to PRAM If an FPI write is performed to a PRAM location that contains a parity error then the PCP generates a memory error when it should not TC1797 QS AC 110 115 Rel 1 4
77. ield SCU_LRSTSTAT ESRO should be cleared In addition it should be checked that bit field SCU_RSTSTAT ESR 1 is also cleared TC1797 QS AC 86 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations If bit field SCU_RSTSTAT ESRO needs to contain a value different from 00 instead of checking bit SCU_RSTSTAT PORST the three bits SCU_RSTSTATCBO SCU_RSTSTATCB1 and SCU_RSTSTATCB3 should be checked to be set SCU_TC 016 Reset Value of Registers ESRCFG0 1 The reset value of register SCU_ESRCFGO is 0x00000100 instead of 0x000001 10 The reset value of register SCU_ESRCFG1 is Ox00000080 instead of 0x00000090 This means that bit DFEN Og i e the digital 3 stage median filter is disabled after a System Reset Note The 3 stage median filter operates on the FPI Bus frequency All input spikes lasting less than one FPI Bus cycle are reliably suppressed Any request lasting at least 2 FPI Bus cycles is reliably recognized Workaround In case the digital 3 stage median filter shall be enabled bit DFEN must be set to 1 by software SSC _AI 022 Phase error detection switched off too early at the end of a transmission The phase error detection will be switched off too early at the end of a transmission If the phase error occurs at the last bit to be transmitted the phase error is lost Workaround Don t use the phase error detection TC1797 QS AC 87 115 Rel 1 4 25 01 2011 Infineon Errata She
78. in the CPU store buffer The word load instruction encounters the circular buffer wrap condition and is split into 2 half word accesses to the top 0xD0001012 and bottom 0xD0001000 of the circular buffer The first load access completes correctly but due to the bug the second access overtakes the store operation and returns the previous half word from 0xD0001000 Workaround For any circular buffer data structure if byte store operations st b are not used targeting the circular buffer or if the circular buffer has a quad word aligned base address and is an even number of words in depth then this problem cannot occur If these restrictions and the other conditions required to trigger the problem cannot be ruled out then any load word instruction Id w targeting the buffer using circular addressing mode and which may encounter the circular buffer wrap condition must be preceded by a single NOP instruction LDA al2 OxDO001000 Circular Buffer Base LDA al3 0x00140012 Circular Buffer Limit and Index st b a12 0x1 d2 Store to byte offset 0x1 nop Workaround ld w d6 al2 al3 c Circular Buffer wrap 16 16 CPU_TC 110 Register Banks may be out of sync after FCU Trap In order to improve the performance of Upper Context Save and Restore operations Call Interrupt etc the current TriCore1 CPU implementation contains shadow registers for the upper context General Purpose Registers GPRs D8 D15 and A10 A15 forming a fore
79. ing this return address against the trap vector address es For example if only the NMI trap is a system issue requiring immediate action the following code may be added to the interrupt handler to determine if the interrupt was taken at the start of the NMI handler lt Timing critical section of Interrupt Handler gt movh a al2 his NMITrapAddress BTV OR OxEO TC1797 QS AC 26 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations lea al2 al2 los NMITrapAddress BTV OR OxEO eq a di3 al2 all Compare with All result in d13 lt Call Branch to NMI handler based on d13 result gt Note that this code segment assumes that the BTV CSFR is static during runtime If this is not the case then it would be necessary to determine the trap offset address during runtime by reading the BTV CSFR and ORing with the TCN offset of the trap of interest If more than one trap class is considered timing critical within a system it is possible to adapt the previous code to check the return address of the interrupt handler against a number or range of trap class entry addresses If the interrupted traps are considered recoverable and are not time sensitive the interrupt handler can simply complete and it s terminating RFE will correctly return execution to the first instruction of the trap handler where it will now execute to completion without undesired interruption If the interrupted traps are considere
80. l 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Example LDA a8 0xD000000E Address of un aligned load LDA al2 0xD0000820 Circular Buffer Base LDA al3 0x00180014 Circular Buffer Limit and Index ld w d6 a8 Un aligned load split 16 16 add d4 d3 d2 Optional IP instruction st d al2 al3 c dO0 dl Circular Buffer wrap 32 32 In this example the word load from address OxDOOOOOOE is split into 2 half word accesses since it spans a 128 bit boundary in LDRAM The double word store encounters the circular buffer wrap condition and should be split into 2 word accesses to the top and bottom of the circular buffer However due to the bug the first access takes the transfer data size from the second part of the un aligned load and only 16 bits of data are written Note that the presence of an optional IP instruction between the load and store transactions does not prevent the problem since the load and store transactions are back to back in the LS pipeline Case 2 Case 2 is similar to case 1 and occurs where a load instruction using circular addressing mode encounters the circular buffer wrap around condition and is preceded in the LS pipeline by a multi access load instruction However for case 2 to be a problem it is necessary that the first access of the load instruction encountering the circular buffer wrap around condition the access to the top of the circular buffer also encounters a con
81. le clock fopra FPl Bus clock and the number of cycles required until the instruction reading SRS is executed the value read from SRS may not yet indicate request_2 but only request_1 unlike case 1 On the other hand flag SRR cleared when request_1 was acknowledged is not set to trigger service for request_2 unlike case 2 As a consequence recognition and service of request_2 will be delayed until the next request of one of the sources connected to this service request group y is generated Identification of Affected Systems A system will not be affected by the corner case described above when the following condition is true 1a READ ACK 2 max icu N 1 FPIDIV for FDR in Normal Mode or 1b READ ACK 2 max icu N FPIDIV for FDR in Fractional Mode with READ number of fepy or focp cycles between interrupt request at CPU PCP site and register SRS read operation 1 SRS abbreviation for Service Request State Registers SRSCn or SRSSn 2 Jopu Jims O fsr depending on bus structure used in specific product TC1797 QS AC 101 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints Number of cycles depends on implementation of service routine Worst case with respect to corner case is minimum time READ R 10 if instruction reading SRS is directly located at entry point in Interrupt Vector Table in CPU Interrupt Service Ssub routine READ R 14 if instruction reading
82. lock up DMA LMB Master Read access the next LMB access and associated response will have the following effect ERROR Response The DMA LMB Master will treat this error response as its own It will clear the lock up state and return an error to the DMA access requester Normal operation will then continue Halted DMA access requests will resume There is no corruption of the data flow e NSC No Special Condition Acknowledge The DMA LMB Master will treat this response as its own and again clear the lock up state The correct response to an unrecognised slave is an ERROR Therefore the DMA LMB Master has signalled an invalid response back to the DMA access requester resulting in a corruption of the data flow e RETRY Response The DMA LMB Master will treat the retry response as its own and again clear the lock up state The access will be repeated to the same reserved address location again resulting in a lock up condition The sequence is broken by the first ERROR response or NSC acknowledge The effect of a DMA LMB Master Write accesses to an unrecognised slave is the same as above with one exception TC1797 QS AC 33 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations e Ifthe next access is a Read access from the EBU LMB Slave then the DMA LMB Master will clear the lock up state and respond as above The EBU read completes but the data read by the Originator e g TriCore will be the write data of the DMA LMB
83. mask becomes effective is needed However two instructions for example two NOPs are required between the clearing instruction and an atomic PRAM instruction MSET PI MCLR PI XCH PI TC1797 QS AC 81 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations PCP_TC 032 Incorrect PCP behaviour following FPI timeouts as a slave When PRAM is being accessed from the FPI bus and an FPI time out occurs then this can lead to corruption or loss of the current and subsequent FPI accesses In general an FPI time out during an access to the PCP is unlikely since FPI time out is usually programmed for a large number of FPI clock cycles and the only time that the FPI access cannot be immediately responded to by the PCP is during the execution of atomic PRAM instructions FPI accesses are locked out for the entire duration of any sequence of back to back atomic PRAM instructions The combination of a low FPI time out setting and long sequences of atomic PRAM instructions could therefore result in FPI time out Workaround Keep the FPI time out setting as high as possible and do not include long sequences of back to back atomic PRAM instructions If N is the highest amount of back to back atomic PRAM instructions in any PCP channel program FPI time out should at least be 10 times N PCP _TC 034 Usage of R7 requires delays between operations If the following instruction sequence is used lt INSTR gt writing to R7 directly follow
84. mbine existing SHOVEN insert d15 d14 d15 0 16 Flush all store data dsync 7 Store New value back to OCON st w a14 di5 Re read to ensure store is complete ld w di5 a14 Attention This routine must be run with interrupts disabled either as part of an interrupt service routine or guarded by enable disable instructions This routine may be run periodically or run as part of a dedicated interrupt service routine If the latter approach is used it is suggested that an unused TC1797 QS AC 32 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations SRN either in the CPU or Cerberus is utilised to trigger the invalidate In all cases the routine must be run with interrupts disabled to ensure that no writes are in progress when the invalidate occurs The OCON OVCONF bit may be used to indicate the state of the invalidate operation If it is cleared in advance the routine above will set it when the cache invalidate operation is performed DMA _TC 013 DMA LMB Master Access to Reserved Address Location DMA LMB Master goes into an unintentional lock up state when a Read or Write access is made to a reserved memory location with an unrecognised slave Subsequent Read Write accesses from a DMA Channel MLI Cerberus or the DMA FPI Slave to all memory locations mapped to the DMA LMB Master 80000000 to DFFFFFFF will be halted until control of the DMA LMB Master is regained In the case of a
85. me the SUC prioritizes the input event of successful integration leaves the state INITIALIZE SCHEDULE CCSV POCS and enters depending of its startup role either INTEGRATION _COLDSTART_CHECK or INTEGRATION _CONSISTENCY_CHECK The reaction of the GTU depends on the related channels and the actual state of clock synchronisation startup process Assumed is that the GTU is in clock synchronization process state CSP A For the combination of integration successful on A and integration abort on B the GTU stops the macrotick generation process and terminates both clock synchronisation startup processes In this case the CC is stuck in TC1797 QS AC 54 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations INTEGRATION_COLDSTART_CHECK or INTEGRATION_CONSISTENCY_CHECK For the other combination of integration successful on B and integration abort on A the GTU stops the macrotick generation process but keeps the clock synchronisation startup process of channel A running This leads to a delayed best case two cycles successful startup of the E Ray If the GTU is in state CSP B active the same is true with the swapped channels The combination of integration successful on B and integration abort on A leads to the stuck condition and the combination of integration successful on A and integration abort on B leads to a delayed startup Scope The erratum is limited to the case o
86. mer_2 are running with different reload values Both timers should start conversions with the requirement of equidistant timing Problem description TC1797 QS AC 41 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Timer_1 becomes zero and starts a conversion Timer_2 becomes zero during this conversion is running and sets the conversion request bit of channel_2 At the end of the conversion for channel_1 this request initiates a start for channel_2 But the Timer_2 is reloaded only when setting the request bit for channel_2 and is decremented during the conversion of channel_1 The correct behavior would be a reload when the requested conversion of channel_2 is started Therefore the start of conversion for channel_2 is delayed by maximum one conversion time After this delay it will be continued with equidistant conversion starts Please refer to the following figure R Timer loaded with Reload value 0 Timer becomes zero Timer_1 DECR Of R DECR Start_chan1 Busy1 conversion time 1 l 1 In hardware implemented feature i 1 Timer_2 DECR 0 R DECR OR DECR OJR DECR 0 R DECR Of R Start_chan2 2 _ gt gt Start shifted progr timer rate progr timer rate 2 Spec comform feature DECR 0 R DECR 0 R DECR Of R DECR OJR Timer_2
87. mic segment in minislots following slot ID 2047 Description In case the slot counter has reached ID 2047 and the end of dynamic segment is not reached the slot counter wraps around to 0 and stays there until the end of the dynamic segment In this state slot counter 0 the E Ray erroneously updates register ACS every minislot The correct behaviour is that the slot status is only updated at the end of the dynamic segment Scope The erratum is limited to the following case gNumberOfStaticSlots gNumberOfMinislots gt cSlotIDMax 2047 Effects In the described case register ACS is updated every minislot until the end of the dynamic segment This update may also lead to an update of error interrupt flags EIR EDA EIR EDB Workaround Avoid configurations with gNumberOfStaticSlots gNumberOfMinislots gt cSlotIDMax FlexRay_Al 070 Cycle counter MTCCV CCV is updated erroneously in ded icated startup states Description TC1797 QS AC 51 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Reading cycle counter value MTCCV CCV during startup may return the value of 1 or 63 instead of the CHI default value of 0 Scope The erratum is limited to parts of following dedicated startup states e Leading coldstart node cycle no schedule at POC state coldstart collision resolution e Following coldstart node cycle 1 at POC state integration coldstar
88. n Reading the PC CSFR whilst in HALT mode will also yield a faulty value Workaround In order to avoid PC corruption the user should avoid placing BAM breakpoints with HALT action on random code which could contain conditional jumps The simplest thing to do is to avoid BAM breakpoints with HALT action altogether A combination of BBM breakpoints and other types of breakpoint actions can be used to achieve the desired functionality Workaround for single stepping An intuitive way of implementing single stepping mode is to place a halt action BAM breakpoint on the address range from Ox00000000 to OxFFFFFFFF Every time the CPU is woken up via the CERBERUS it will execute the next instruction and go back to HALT mode Unfortunately this will trigger the bug described by the current ERRATA The solution is to implement single stepping using BBM breakpoints e 1 Create two debug trigger ranges e First range 0x00000000 to current_instruction_pc not included e Second range current_instuction_pc not included to OxFFFFFFFF e 2 Associate the two debug ranges with BBM breakpoints e 3 Associate the BBM breakpoints with a HALT action e 4 Wake up the CPU via CERBERUS e 5 CPU will execute the next instruction update the PC and go to HALT mode e 6 Start again go back to 1 TC1797 QS AC 79 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations OCDS _TC 028 Accesses to CSFR and GPR registers of run
89. nal RAMs requires New 98 one eray_bclk cycle more FlexRay_Al H006 Transmission in ATM Loopback mode New 99 FlexRay_Al H007 Reporting of coding errors via New 99 TEST1 CERA B FlexRay_AI H009 Return from test mode operation New 99 FPI_TC HO001 FPI bus may be monopolized despite 100 starvation protection GPTA_TC H004 Handling of GPTA Service Requests New 100 HYS_TC H001 Effective Hysteresis in Application 104 Environment MSC_TC H007 Start Condition for Upstream Channel 104 MSC_TC H008 The LVDS pads require a settling time 105 when coming up from pad power down state MSC_TC H009 Incorrect MSCO Interconnections New 106 specified in User s Manual V1 1 MultiCAN_AI H005 TxD Pulse upon short disable request 106 MultiCAN_AI H006 Time stamp influenced by 106 resynchronization MultiCAN_TC H002 Double Synchronization of receive input 107 MultiCAN_TC H003 Message may be discarded before 107 transmission in STT mode MultiCAN_TC H004 Double remote request 107 OCDS_TC H001 IOADDR may increment after aborted 108 TC1797 QS AC IO_READ_BLOCK 11 115 Rel 1 4 25 01 2011 Cafineon Errata Sheet History List Change Summary Table 6 Application Hints cont d Hint Short Description Cha Pa nge ge OCDS_TC H002 Setting IOSR CRSYNC during Application 108 Reset OCDS_TC H003 Application Reset during host 109 communication OCDS_TC H004 Device Identif
90. nd condition the first access to the circular buffer may be performed using an incorrect data size causing too many or too few data bytes to be transferred The circular buffer wrap around condition occurs when a load or store instruction using circular addressing mode addresses a data item which spans the boundary of a circular buffer such that part of the data item is located at the top of the buffer with the remainder at the base The problem may occur in one of two cases Case 1 Where a store instruction using circular addressing mode encounters the circular buffer wrap around condition and is preceded in the LS pipeline by a multi access load instruction the first access of the store instruction using circular addressing mode may incorrectly use the transfer data size from the second part of the multi access load instruction A multi access load instruction occurs in one of the following circumstances e Unaligned access to LDRAM or cacheable address which spans a 128 bit boundary e Unaligned access to a non cacheable non LDRAM address e Circular addressing mode access which encounters the circular buffer wrap around condition Since half word store instructions must be half word aligned and sta instructions must be word aligned they cannot trigger the circular buffer wrap around condition As such this case only affects the following instructions using circular addressing mode st w st d st da TC1797 QS AC 16 115 Re
91. ng instead of zero Scope The erratum is limited to the case where the calculated rate correction value is in the range of pClusterDriftDamping pClusterDriftDamping Effects The displayed rate correction value RCV RCV 11 0 is in the range of pClusterDriftDamping pClusterDriftDamping instead of zero The error of the displayed value is limited to the range of pClusterDriftDamping pClusterDriftDamping For rate correction in the next double cycle always the correct value of zero is used Workaround A value of RCV RCV 11 0 in the range of pClusterDriftDamping pClusterDriftDamping has to be interpreted as zero FlexRay Al 096 Noise following a dynamic frame that delays idle detec tion may fail to stop slot Description If in case of noise the time between potential idle start on X and CHIRP on X see Protocol Spec v2 1 Figure 5 21 is greater than gdDynamicSlotldlePhase the E Ray will not remain for the remainder of the current dynamic segment in the state wait for the end of dynamic slot rx Instead the E Ray continues slot counting This may enable the node to further transmissions in the current dynamic segment TC1797 QS AC 67 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Scope The erratum is limited to noise that is seen only locally and that is detected in the time window between the end of a dynamic frame s DTS and idle detection CHIRP
92. ng to the non clocked SDL description This behaviour does not violate the FlexRay protocol conformance It has to be considered only when TEST1 CERA B is evaluated by a bus analysis tool FlexRay AI H009 Return from test mode operation The E Ray FlexRay IP module offers several test mode options e Asynchronous Transmit Mode Loop Back Mode e RAM Test Mode 1 0 Test Mode To return from test mode operation to regular FlexRay operation we strongly recommend to apply a hardware reset via input eray_reset to reset all E Ray internal state machines to their initial state TC1797 QS AC 99 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints Note The E Ray test modes are mainly intended to support device testing or FlexRay bus analyzing Switching between test modes and regular operation is not recommended FPI_TC H001 FPI bus may be monopolized despite starvation protection During a sequence of back to back 64 bit writes performed by the CPU to PCP memories PRAM CMEM the LFI will lock the FPI bus and no other FPI master PCP DMA OCDS will get a grant regardless of the priority until the sequence is completed A potential situation would be a routine which writes into the complete PRAM and CMEM to initialize the parity bits for devices with parity or ECC bits for devices with ECC respectively If the write accesses are tightly concatenated the FPI bus may be monopolized during this time
93. ning program can corrupt loop exits Overview A hardware problem has been identified whereby FPI accesses to the OxF7E10000 OxXxF7E1FFFF region will potentially corrupt the functionality of the Tricore LOOP instruction This is particularly relevant because the Tricore CPU CSFR and GPR registers are mapped to that region So any access to those registers by an external agent will potentially cause the LOOP instruction not to work Note that this problem will not happen if the CPU was halted at the time of the FPI access Typical bug behaviour The loop instruction should exit fall through when its loop count operand is zero The identified problem will typically cause the loop instruction to underflow instead of exiting when its loop count operand is zero the loop instruction will erroneously jump back to its target with a 1 OxFFFFFFFF loop counter value and then continue to iterate possibly ad infinitum Note that the offending FPI access will not cause the bug to happen immediately but only when the loop instruction finally tries to exit Influencing factors The following factors influence the likelihood of the bug happening 1 The bug will not happen if the LOOP instruction and its predecessor are both entirely contained in the same aligned 8 byte word 2 The bug is much less likely to happen if the CPU is running from program cache or program scratchpad 3 The problem will be more visible on later compiler versions w
94. ns In particular flag STAT BSY will change twice during data transmission from 0 to 1 at the start and from 1 to 0 at the end of a transmission This requires some special considerations e g when polling for the end of a transmission In master mode when register TB has been written while no transfer was in progress flag STAT BSY is set to 1 after a constant delay of 5 FPI bus clock cycles When software is polling STAT BSY after TB was written and it finds that STAT BSY Og this may have two different meanings either the transfer has not yet started or it is already completed Recommendations In order to poll for the end of an SSC transfer the following alternative methods may be used e either test flag RSRC SRR receive interrupt request flag instead of STAT BSY or use a software semaphore that is set when TB is written and which is cleared e g in the SSC receive interrupt service routine TC1797 QS AC 115 115 Rel 1 4 25 01 2011
95. o correct the offset of one macrotick pOffsetCorrectionOut gt gt gdMacrotick the node enters NORMAL_ACTIVE with the first startup attempt If the node is not able to correct the offset error because pOffsetCorrectionOut is too small pOffsetCorrectionOut lt gdMacrotick the node enters ABORT_STARTUP and is ready to try startup again The next second startup attempt is not effected by this erratum Scope The erratum is limited to applications where READY command is used to leave STARTUP NORMAL_ACTIVE or NORMAL_PASSIVE state Effects In the described case the integrating node tries to correct an erroneous cycle offset of one macrotick during startup Workaround With a configuration of pOffsetCorrectionOut gt gt gdMacrotick 1 cClockDeviationMax the node will be able to correct the offset and therefore also be able to successfully integrate TC1797 QS AC 69 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations FlexRay AlI 100 First WUS following received valid WUP may be ignored Description When the protocol engine is in state WAKEUP_LISTEN and receives a valid wakeup pattern WUP it transfers into state READY and updates the wakeup status vector CCSV WSV 2 0 as well as the status interrupt flags SIR WST and SIR WUPA B If the received wakeup pattern continues the protocol engine may ignore the first wakeup symbol WUS following the state transition and signals the next SIR WUPA B
96. occur during power up It can not happen during power down or power fail The following table classifies the V5p Vppp ranges with respect to peak severity TC1797 QS AC 112 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints Table 14 Worst Case Power up Cross Current Vop Vppp Comment gt 0 5V don t care normal operation lt 0 5V lt 0 8V lbpp lt 4 MA lt 0 5V 0 8 V lt Vbpp lt 1 0 V Ibpp lt 9 MA lt 0 5V 3 6 V lbpp lt 472 MA Even under worst case conditions this effect has no impact on lifetime nor reliability SSC_AI H001 Transmit Buffer Update in Slave Mode after Transmission If the Transmit Buffer register TB is written in slave mode in a time window of one SCLK cycle after the last SCLK edge i e after the last data bit of a transmission the first bit to be transmitted may not appear correctly on line MRST Note This effect only occurs if a configuration with PH 1 shift data on trailing edge is selected It is therefore recommended to update the Transmit Buffer in slave mode after the transmit interrupt TIR has been generated after first SCLK phase of first bit and before the current transmission is completed before last SCLK phase of last bit As this may be difficult to achieve in systems with high baud rates and long interrupt latencies alternatively the receive interrupt at the end of a transmission may be used A delay of 1 5 SCLK cycles bit time
97. on rounds in the ICU because a high priority value can be seen as priority 0 Example 11000000 with 3 arbitration rounds will be seen as 00000000 TC1797 QS AC 111 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints PORTS_TC H004 Using LVDS Ports in CMOS Mode The following constraint applies to an LVDS pair used in CMOS mode Only one pin of a pair shall be used as output the other shall be used as input Using both pins as outputs or inputs simultaneously is not allowed because of the cross coupling between them PORTS TC H005 Pad Input Registers do not capture Boundary Scan data when BSD mode signal is set to high The principle of Boundary Scan is that the BSD cells can overrule the input and output data for all functional system components including port input registers In current implementation the peripheral port input registers P lt n gt _IN are however capturing the direct pad input data even when the BSD mode signal is set to high This limits the usage of INTEST Work around In case of INTEST do not read port input registers PWR_TC HO05 Current Peak on Vppp during Power up During power up a current peak may be observed on Vppp It is caused by internal cross currents generated by level shifters whose state is undefined until the core voltage reaches at least 0 5V This effect is statistical and may vary from one device to the other upon operating conditions etc This effect may only
98. operation with DCINVAL valid clean gt write DCINVAL gt invalid dirty invalid clean gt write DCINVAL gt invalid dirty This leads to a loss of data as the store data ends up being held in an invalid cache line and hence never re read Workaround 1 Ensure that the data cache is never used to cache write data This can be ensured by software design but may limit performance in some systems TC1797 QS AC 31 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Workaround 2 Ensure that the core is never storing data when OCON DCINVAL is asserted This requires the CPUs store buffers to be empty when the invalidate is asserted This can only be done by getting the CPU to firstly flush all write data with a DSYNC command then to write the OCON DCINVAL to trigger an invalidate The following example code sequence performs the required operations e Read the OCON register to get the current SHOVEN field e Create a new OCON value with DCINVAL OVSTRT and OVCONF bits set e Perform a DSYNC operation to flush all write data to memory e Write OCON with the new value e Read back OCON to ensure write is complete 7 Set up A14 with address of OCON Register movh a al4 0xF87FFBE0O 0x8000 gt gt 16 amp Oxffff lea al4 a14 0xF87FFBEO 0x8000 amp Oxffff 0x8000 7 Load al5 with contents of OCON ld w di5 al4 77 Set OCONF DCINVAL OVSTRT start values movh di4 0x0305 7 Co
99. ore the next set of conversions when the power saving state is left Note The selected internal operating frequency of the analog part that determines the conversion time will also influence the sample time ts The sample time ts can individually be adapted for the analog input channels via bit field STC CPU_TC H004 PCXI Handling Differences in TriCore1 3 1 The TriCore1 3 1 core implements the improved architecture definition detailed in the TriCore Architecture Manual V1 3 8 This architecture manual version continues the process of removing ambiguities in the description of context save and restore operations a process started in Architecture Manual V1 3 6 released October 2005 1 Symbol used depends on product family e g fana is used in the documentation of devices of the AUDO NextGeneration family TC1797 QS AC 92 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints Several previous inconsistencies regarding the updating of the PCXI and the storing of PCXI fields in the first word of a CSA are now removed e CALL has always placed the full PCXI into the CSA e BISR has always placed the full PCXI into the CSA e SVLCX has always placed the full PCXI into the CSA e RET has always restored the full PCXI from the CSA e RFE has always restored the full PCXI from the CSA From the TriCore V1 3 8 architecture manuals onwards it is also made explicit that e CALL BISR and SVLCX now explicitly update the PCXI
100. ored 7 115 Rel 1 4 25 01 2011 Cafineon Errata Sheet History List Change Summary Table 4 Functional Deviations cont d Functional Short Description Cha Pa Deviation nge ge FlexRay_Al 101 READY command accepted in READY New 70 state FlexRay_Al 102 Slot Status vPOC SlotMode is reset New 71 immediately when entering HALT state OCDS _AI 001 DAP restart lost when DAPO inactive 71 OCDS_AI 002 JTAG Instruction must be 8 bit long 72 OCDS_TC 014 Triggered Transfer does not support half 73 word bus transactions OCDS_TC 015 IOCONF register bits affected by 73 Application Reset OCDS_TC 016 Triggered Transfer dirty bit repeated by 74 IO_READ_TRIG OCDS_TC 018 Startup to Bypass Mode requires more 74 than five clocks with TMS 1 OCDS_TC 020 ICTTA not used by Triggered Transfer to 74 External Address OCDS_TC 021 TriCore breaks on de assertion instead of 75 assertion of break bus OCDS_TC 024 Loss of Connection in DAP three pin Mode 76 OCDS_TC 025 PC corruption when entering Halt mode 77 after a MTCR to DBGSR OCDS_TC 026 PSW PRS updated too late after a RFM 77 instruction OCDS_TC 027 BAM breakpoints with associated halt 79 action can potentially corrupt the PC OCDS_TC 028 Accesses to CSFR and GPR registers of New 80 running program can corrupt loop exits PCP_TC 023 JUMP sometimes takes an extra cycle 81 PCP_TC 027 Longer delay when clearing R7 IEN befor
101. pstream channel is switched on bit field URR in register USR is set to a value different from 000 and the SDI line is already on a low level or e after a frame has been received and the SDI line is on a low level at the end of the last stop bit time slot e g when the SDI line is permanently held low Therefore make sure that the SDI line is pulled high e g with an internal or external pull up while no transmission is performed TC1797 QS AC 104 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints MSC_TC H008 The LVDS pads require a settling time when coming up from pad power down state The LVDS pad power down state is the default state for the LVDS pad at power up e all resets including software reset e as soon as the LVDS is disabled by PDR register The settling time until reaching normal operating electrical levels is defined as the duration between programming of the relevant PDR register to enable LVDS and the time where the LVDS pads reach the specified operating levels in the datasheets This settling time e increases with decreasing temperature first order e decreases with increasing voltage supply Vppp Second order e is not dependent on the external capacitive load on the LVDS pads e is not dependent on the system frequency The settling time is shown in the Table 1 below Table 13 LVDS pads settling time Conditions Typical Maximum 25 C Vopp 3 3
102. r the difference of the deviation values on both channels is expected to be very low Therefore the error of the local time caused by the implementation error is also minimized FlexRay Al 067 Reception of more than gSyncNodeMax different sync frames per double cycle Description In case of receiving gSyncNodeMax or more sync frames in an even cycle only frames with the same sync frame IDs as received in the even cycle may be used for offset correction term calculation in the following odd cycle The E Ray erroneously uses the first gsyncNodeMax sync frames for offset correction term calculation in the odd cycle regardless whether they have been also received in the previous even cycle Scope The erratum is limited to the case where more than gSyncNodeMax nodes are configured to transmit sync frames and where different sets of sync frames are transmitted in even and odd cycle Effects In the described case the offset correction term may base on a different set of sync frames than the rate correction term In this case registers ESIDn OSIDn hold the IDs of the first received sync frames up to gSyncNodeMax used for offset correction term calculation TC1797 QS AC 50 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Workaround Avoid faulty configurations with more than gSyncNodeMax nodes configured to be transmitter of sync frames FlexRay Al 069 Update of Aggregated Channel Status Acs in dyna
103. rase DFx gt erase DFx gt program DFy suspend erase DFx As a consequence sector DFx may not be correctly erased after the suspended erase has been completed i e DFx may be weakly programmed The effect is non permanent i e erasing DFx again will solve the issue Note Sector DFy is always correctly programmed Therefore both Data Flash sectors or a Program and a Data Flash sector must not be erased one after the other if the second erase operation might be suspended Workaround 1 Additionally program a page of Data Flash sector DFx or DFy before starting the erase of DFx e g TC1797 QS AC 43 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations 1 Erase PFLASH or DFx or DFy 2 Additional step Program DFx or DFy specified rules for Data Flash page programming must remain valid check for completion of programming busy 3 any operation except erase of DFx DFy or PFLASH Erase DFx 5 Concurrent programming of DFy may be triggered gt Workaround 2 After starting the erase of Data Flash sector DFx delay the start of the programing of sector DFy by at least 250 ms e g 1 Erase DFx 2 Additional step Wait gt 250 ms 3 Concurrent programming of DFy may be triggered Workaround 3 Issue a reset in case of two consecutive erase operations without intermediate programming e g Erase DFx Erase DFy Additional step Reset Erase DFx if needed Concurren
104. ring host communication Not only the host is able to cause resets of the device External pins driven by the application the internal watchdog and even the application program itself can trigger the reset generation process The only way to communicate reset events to the host is for Cerberus to reject the next instruction with never ending busy which should lead to communication time out on the host side The decision to accept or reject an instruction is done very early in the bit stream of the instruction If an Application Reset happens after this point of time the instruction will complete in most cases and only the next one will be rejected As the temporal distance from reset event and instruction rejection is not fixed apart from being sequential it is highly recommended to check the IOINFO register using the O_SUPERVISOR instruction each time an abnormally long busy period is experienced by the host Especially a repetition of the rejected instruction should only be attempted if the possibility of Cerberus being in Error State has been excluded Workaround Use l O_SUPERVISOR whenever a too long busy bit is observed TC1797 QS AC 109 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints OCDS_TC H004 Device Identification by Application Software While each device type can easily be recognized by test equipment using the JTAG ID over the years each device family has had a proprietary way to prov
105. ronization The time stamp measurement feature is not based on an absolute time measurement but on actual CAN bit times which are subject to the CAN resynchronization during CAN bus operation The time stamp value merely indicates the number of elapsed actual bit times Those actual bit times can be shorter or longer than nominal bit time length due to the CAN resynchronization events Workaround None TC1797 QS AC 106 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints MultiCAN TC H002 Double Synchronization of receive input The MultiCAN module has a double synchronization stage on the CAN receive inputs This double synchronization delays the receive data by 2 module clock cycles If the MultiCAN is operating at a low module clock frequency and high CAN baudrate this delay may become significant and has to be taken into account when calculating the overall physical delay on the CAN bus transceiver delay etc MultiCAN TC H003 Message may be discarded before transmission in STT mode If MOFCRn STT 1 Single Transmit Trial enabled bit TXRQ is cleared TXRQ 0 as soon as the message object has been selected for transmission and in case of error no retransmission takes places Therefore if the error occurs between the selection for transmission and the real start of frame transmission the message is actually never sent Workaround In case the transmission shall be guaranteed it is not suitable to use th
106. s after the receive interrupt last SCLK edge of transmission should be provided before updating the Transmit Buffer of the slave The master must provide a pause that is sufficient to allow updating of the slave Transmit Buffer before starting the next transmission TC1797 QS AC 113 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints SSC _AI H002 Transmit Buffer Update in Master Mode during Trailing or Inactive Delay Phase When the Transmit Buffer register TB is written in master mode after a previous transmission has been completed the start of the next transmission generation of SCLK pulses may be delayed in the worst case by up to 6 SCLK cycles bit times under the following conditions e a trailing delay SSOTC TRAIL gt 0 and or an inactive delay SSOTC INACT gt 0 is configured e the Transmit Buffer is written in the last module clock cycle fssc or ferc of the inactive delay phase if INACT gt 0 or of the trailing delay phase if INACT 0 No extended leading delay will occur when both TRAIL 0 and INACT 0 This behaviour has no functional impact on data transmission neither on master nor slave side only the data throughput determined by the master may be slightly reduced To avoid the extended leading delay it is recommended to update the Transmit Buffer after the transmit interrupt has been generated i e after the first SCLK phase and before the end of the trailing or inactive d
107. s overwritten by the payload data from the second frame Scope The erratum is limited to cases where the complete header and a part of the payload of another frame is received in slot N TC1797 QS AC 57 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Slot N Slot N 1 TSS FSS 50 bit 40 bit max 40 belk Figure 2 The second frame starts in the same slot The transfer of a received valid frame from TBF to MBF is initiated by the end of the actual slot Execution is started not later than 40 bclk periods after the slot change 40 bclk periods equate 10 bit times when bclk 40MHz Corruption of payload occurs when a transfer from PRT to TBF happens in the red marked time window between start of new slot and start of transfer from TBF to MBF Effects The first two words 4 byte of the received valid frame s payload are corrupted Workaround 1 Ensure that the static slot length is configured suited to the static payload length 2 Check Message Buffer Status for boundary violation FlexRay Al 080 CLEAR_RAMS command does not clear the 1st RAM word Description After execution of the CLEAR_RAMS command the 1st RAM word holds the last data written to IBF Reason is that the registers to support byte access to TC1797 QS AC 58 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations the RAM are cleared one clock cycle after the CLEAR_RAMS command was started
108. s detected in the same slot and the STRP of the valid sync frame occures simultanoeusly with the action point the temporal deviation value of the first detected STRP is stored instead of the value of the correct STRP Scope The erratum is limited to the case of noise before reception of a valid sync frame ora frame reception starting before action point is aborted and then a valid sync frame is received in the same slot Effects In the described case a wrong deviation value is used for correction term calculation Depending on number of sync frames and other measured temporal deviation values it may lead to an incorrect rate or offset correction value Workaround None FlexRay Al 064 Valid frame detection at slot boundary Description In case a non sync frame is detected to be valid simultaneously with the slot boundary and in the following slot a sync frame is received the temporal TC1797 QS AC 47 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations deviation value time between primary time reference point and action point of the received sync frame is erroneously set to the measured value of the previous non sync frame Scope The erratum is limited to the case where a non sync frame is received in one slot and a sync frame is received in the following slot Additionally the detection of valid frame for the non sync frame has to be exactly at the slot boundary Effects The temporal
109. s step Errata Short Description Change TC1797 QS AC 3 115 Rel 1 4 25 01 2011 Cafineon Errata Sheet History List Change Summary Table 4 Functional Deviations Functional Short Description Cha Pa Deviation nge jge BCU_TC 006 Polarity of Bit SVM in Register ECON 13 BROM_TC 005 Power on reset PORST while no external 13 clock is available CPU_TC 105 User Supervisor mode not staged 13 correctly for Store Instructions CPU_TC 106 Incorrect PSW update for certain IP 14 instructions dual issued with MTCR PSW CPU_TC 107 SYSCON FCDSF may not be set after FCD 15 Trap CPU_TC 108 Incorrect Data Size for Circular 16 Addressing mode instructions with wrap around CPU_TC 109 Circular Addressing Load can overtake 19 conflicting Store in Store Buffer CPU_TC 110 Register Banks may be out of sync after 22 FCU Trap CPU_TC 111 Imprecise Return Address for FCU Trap 24 CPU_TC 113 Interrupt may be taken during Trap entry 25 sequence CPU_TC 114 CAE Trap may be generated by UPDFL 28 instruction CPU_TC 115 Interrupt may be taken on exit from Halt 29 mode with Interrupts disabled CPU_TC 117 Cached Store Data Lost on Data Cache New 31 Invalidate via Overlay DMA_TC 013 DMA LMB Master Access to Reserved 33 Address Location DMI_TC 014 Problems with Parity Handling in TriCore 34 Data Memories TC1797 QS AC 4 115 Rel 1 4 25 01 2011 Infineon Errata Sheet History Li
110. s the circular buffer wrap condition and should be split into 2 word accesses to the top and bottom of the circular buffer In addition the first circular buffer access conflicts with the store to address 0xD0000834 Due to the bug after the store buffer is flushed the first access takes the transfer data size from the second part of the un aligned load and only 16 bits of data are read Note that the presence of an optional IP instruction between the two load transactions does not prevent the problem since the load transactions are back to back in the LS pipeline Workaround Where it cannot be guaranteed that a word or double word load or store instruction using circular addressing mode will not encounter one of the corner cases detailed above which may lead to incorrect behaviour one NOP instruction should be inserted prior to the load or store instruction using circular addressing mode LDA a8 0xD000000E Address of un aligned load LDA al2 0xD0000820 Circular Buffer Base LDA al3 0x00180014 Circular Buffer Limit and Index ld w d6 a8 Un aligned load split 16 16 add d4 d3 d2 Optional IP instruction nop Bug workaround st d al2 al3 c dO dl Circular Buffer wrap 32 32 CPU_TC 109 Circular Addressing Load can overtake conflicting Store in Store Buffer In a specific set of circumstances a load instruction using circular addressing mode may overtake a conflicting store held in the TriCore1 CPU store buf
111. signalled to the SCU TC1797 QS AC 34 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations and returned to the CPU as an NMI trap rather than as a DIE trap directly to the CPU AND e Ifthe system has a data cache the data cache must be used to cache read only data only such as Flash contents Writes to cacheable locations must not be used with the Data Cache enabled Note that this does not concern the program side which works as expected DMI_TC 015 LDRAM Access Limitations for 2KByte Data Cache Configu rations TriCore1 3 1 based devices are physically built with a certain size of Data Memory DMEM and a data tag memory to support a certain maximum size of Data Cache DCache Within these physical limitations software may select the exact split between LDRAM and DCache where DMEM size LDRAM size DCache size The software selection is performed according to the configuration of the DCache size in DMI_CON DC_SZ_ CFG with any DMEM not configured as DCache ordinarily available as LDRAM However a problem exists where the DCache is configured to be 2KByte DMI_CON DC_SZ_CFG 0001 In this case the expected amount of LDRAM is available for accesses from the CPU DMEM size 2KByte but the address range checking is incorrect for accesses to LDRAM from the LMB and the available LDRAM size for LMB accesses is limited to DMEM size 4KByte Example A TC1767 device is physically built to suppor
112. ss which targets an address which is not word aligned or a data address double word access which is not double word aligned e The mis aligned load access targets a cacheable address whether the device is configured with a data cache or not e The mis aligned load access spans two halves of the same 128 bit cache line For instance a data word access with address offset 6 e The mis aligned load access results in a cache miss which will refill the 128 bit cache line Data Line Buffer DLB via a Block Transfer 2 BTR2 read transaction on the LMB and this LMB read encounters a bus error condition in the second beat of the block transfer It should be noted that under normal operation LMB block transfers will not result in a bus error condition being flagged on the second beat of a block transfer However such a condition may be encountered when accessing the on chip Flash if the second double word of data accessed from the Flash for the second half of the cache line contains an uncorrectable double bit error TC1797 QS AC 36 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations When this condition is triggered the first part of the requested data is obtained from the valid first beat of the BTR2 transfer and the second part is required from the errored second beat In this case no error is flagged to the TriCore CPU and the transaction is incorrectly re started on the LMB In the case of a Flash double
113. st Change Summary Table 4 Functional Deviations cont d Functional Short Description Cha Pa Deviation nge ge DMI_TC 015 LDRAM Access Limitations for 2KByte 35 Data Cache Configurations DMI_TC 016 CPU Deadlock possible when Cacheable 36 access encounters Flash Double Bit Error DMI_TC 017 DMI line buffer is not invalidated by a write 38 to OVC_OCON DCINVAL if cache off EBU_TC 020 BAA Delay Options Controlled by Wrong 39 Register Field EBU_TC 021 Incorrect delay calculation accessing 40 Asynchronous memories EBU_TC 022 Write Data Delay Control for 40 Asynchronous Memory Accesses FADC_TC 005 Equidistant multiple channel timers 41 FIRM_TC 010 Data Flash Erase Suspend Function 43 FLASH_TC 027 Flash erase time out of specification Upd 45 ate FLASH_TC 035 Flash programing time out of specification 46 FlexRay_Al 056 In case eray_bclk is below eray_sclk 2 46 TEST1 CERA B may fail to report a detected coding error FlexRay_Al 062 Sync frame reception after noise or 47 aborted frame before action point FlexRay_Al 064 Valid frame detection at slot boundary 47 FlexRay_Al 065 For sync nodes the error interrupt flag 48 EIR SFO may be set too late FlexRay_Al 066 Time stamp of the wrong channel may be 49 used for offset correction term FlexRay_Al 067 Reception of more than gSyncNodeMax 50 different sync frames per double cycle TC1797 QS AC 5 115 Rel 1 4
114. t a maximum of 72KByte DMEM and 4KByte DCache Where the DCache size is configured as 4KByte available LDRAM is 68KByte where the DCache size is configured as OKByte available LDRAM is 72KByte However when the DCache size is configured as 2KByte 7OKByte LDRAM is addressable by the CPU but only the bottom 68KByte is addressable by LMB bus masters TC1797 QS AC 35 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Workaround In systems where a 2KByte DCache is configured the top 2KByte of LDRAM is only available for usage by the CPU and cannot contain data structures that may be required by other bus masters For instance this space could be used as part of the CSA list However note that since this memory is not addressable by LMB masters in the 2KByte DCache configuration this would affect debuggers Hence it would only be possible to view this memory space in a debugger if it takes appropriate steps to make the memory region accessable e g by temporarily setting the DCache size to OKByte to examine that address range DMI_TC 016 CPU Deadlock possible when Cacheable access encounters Flash Double Bit Error A problem exists whereby the TriCore CPU may become deadlocked when attempting a mis aligned load access to a cacheable address The problem will be triggered in the following situation The TriCore CPU executes a load instruction whose target address is not naturally aligned a data word acce
115. t check e Integrating node cycle 1 at POC state integration consistency check Effects MTCCV CCV is updated with the correct internal value of 1 or 63 Workaround Ignore MTCCV CCV during startup FlexRay Al 071 Faulty update of LDTS LDTA LDTB 10 0 due to parity error Description In case a parity error occurs when the message handler transfers data from the Message RAM to the Transient Buffer it may happen that the transmission is not started Scope The erratum is limited to cancelled transmissions of dynamic frames when a parity error occurs during data transfer from Message RAM to the Transient Buffer Effects TC1797 QS AC 52 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations When the described condition occurs the slot counter value is captured and LDTS LDTA LDTAB 10 0 is updated with this value at the end of the dynamic segment Workaround None FlexRay Al 072 Improper resolution of startup collision Description In case a CAS symbol is received during startup exactly at the beginning of cycle 0 the detection of following startup frames is not possible Scope The erratum is limited to the case where a CAS symbol is received during startup exactly at the beginning of cycle 0 Effects In the described case the CC is not able to transit from STARTUP to NORMAL_ACTIVE state Workaround Leave and re enter STARTUP state by Host commands READY and RUN
116. t programming of DFy may be triggered akwON gt Workaround 4 After a concurrent erase on Data Flash sector DFx has been triggered verify the state of DFx In case of weak programming re erase DFx Additional step Workaround 5 Do not use concurrent erase program operations on Data Flash TC1797 QS AC 44 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations FLASH _TC 027 Flash erase time out of specification As per specification in the Data Sheet following are the flash erase timings Table 8 Flash erase timings as per spec Flash Micro Erase Time code version P Flash 2 MByte V11 40s at cold and room temperature D Flash 64 Kbyte Both V11 2 5s at cold temperature Data Flash Actual Flash erase timings may reach the following maximum values A minimum erase time budget per erase operation of 0 5 s must however be tolerated regardless of size proportional erase times derived from the table Table 9 Actual Flash erase timings Flash Micro Erase Time code version P Flash 2 MByte V11 52s at cold temperature 45s at room and above temperature D Flash 64 Kbyte Both V11 3 2s at all temperature Data Flash Maximum erase time at various CPU operating frequencies can be calculated according to the following table Frequency dependency for Data Flash is lower than for Program Flash TC1797 QS AC 45 115 Rel 1 4 25 01 2011 Infineon Errata
117. t the IOADDR register is incremented nevertheless This will result in an access to the wrong data in the succeeding O_READ_ or O_WRITE_ instruction Workaround As the host is actively causing the abort it should be fully aware of the situation The workaround now simply is to rewrite the IOADDR register using the 1O_SET_ADDRESS instruction after each aborted block transfer Note This usually is done anyway at the beginning of the next transaction OCDS _TC H002 Setting IOSR CRSYNC during Application Reset If the host is shifting in a Communication Mode IO_READ_WORD instruction in the very moment an Application Reset happens the read request flag CBS_IOSR CRSYNC may be already set after the execution of the startup TC1797 QS AC 108 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints software A monitor program may be confused by this and drop out of the higher level communication protocol especially if the host posts an instruction with the 1O_WRITE_WORD instruction after detecting the reset Workaround Two correlated activities should be incorporated in the tool software After each reset the host should explicitly use CBS_IOCONF COM_RST to reset any erroneously pending requests The higher level protocol should require a specific answer to the very first command sent from the host to the device Erroneous read requests then can be detected and skipped OCDS TC H003 Application Reset du
118. the cluster FlexRay Al 094 Sync frame overflow flag EIR SFO may be set if slot counter is greater than 1024 Description If in the static segment the number of transmitted and received sync frames reaches gSyncNodeMax and the slot counter in the dynamic segment reaches the value cStaticSlotIDMax gSyncNodeMax 1023 gSyncNodeMax the sync frame overflow flag EIR SFO is set erroneously Scope The erratum is limited to configurations where the number of transmitted and received sync frames equals to gSyncNodeMax and the number of static slots plus the number of dynamic slots is greater or equal than 1023 gSyncNodeMax Effects In the described case the sync frame overflow flag EIR SFO is set erroneously This has no effect to the POC state Workaround Configure gSyncNodeMax to number of transmitted and received sync frames plus one or avoid configurations where the total of static and dynamic slots is greater than cStaticSlotIDMax TC1797 QS AC 66 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations FlexRay Al 095 Register RCV displays wrong value Description If the calculated rate correction value is in the range of pClusterDriftDamping tpClusterDriftDamping vRateCorrection of the CSP process is set to zero In this case register RCV should be updated with this value Erroneously RCV RCV 11 0 holds the calculated value in the range pClusterDriftDamping pClusterDriftDampi
119. the following situation TC1797 QS AC 28 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations e After execution of the UPDFL instruction one or more of the PSW 31 26 bits are set either the PSW bit s are set by UPDFL or were set prior to execution and not cleared by the UPDFL instruction e FPU traps are enabled for one of the asserted PSW 31 26 bits via the corresponding FPU_TRAP_CON FxE bit being set e The FPU_TRAP_CON TST CSFR bit is clear no previous FPU trap has been generated without the subsequent clearing of FPU_TRAP_CON TST Workaround The UPDFL instruction is normally used in one of two situations e Clearing the FPU sticky flags held in PSW 30 26 Setting the FPU rounding mode bits in PSW 25 24 In the first case if all the PSW 31 26 bits are cleared by UPDFL no CAE trap will be generated In the second case UPDFL may still be used to set the FPU rounding mode but in this case the remaining PSW bits 31 26 must be cleared by UPDFL in order to avoid generation of an unexpected CAE trap In all other cases where FPU traps are enabled some other method of manipulating the PSW user status bits must be used in order to avoid extraneous CAE trap generation For instance if in Supervisor mode the PSW may be read using the MFCR instruction the high order PSW bits modified and written back using the MTCR instruction CPU_TC 115 Interrupt may be taken on exit from Halt mode with
120. the new MSB Upon entry to the Update IR state the content of the internal shift register is copied into the INSTRUCTION register unconditionally If the final state of the shift register happens to be a valid but unintended instruction the device may enter a state very detrimental to the application An extreme example is the INTEST instruction which turns off all outputs of the device and is activated by instruction 01 i e if no bit at all is shifted in by the host Recommendations e Always shift in at least as many bits as the INSTRUCTION register holds This means 8 bit for Infineon devices TC1797 QS AC 72 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations e Check the bits returned via TDO Must be 01 followed by any data shifted in excluding the last eight bits This allows to check the pipe by shifting in more than the required 8 bits e Use the protection offered by IOPATH Keeping IOPATH different from 00 whenever possible will block all Boundary Scan functions e Do not use the DAP telegrams jtag_setIR and jtag_swapIR with n less than eight e Use the CRC protected DAP interface if the application environment may cause transmission errors on the JTAG signals OCDS _TC 014 Triggered Transfer does not support half word bus trans actions The register bit CBS_lIOCONF EX_BUS_HW does not have any influence on the transaction width only word wide transfer 32 bit is implemented Work
121. tion is encountered which targets an address for which at least part of the requested data is currently held in the CPU store buffer In this store buffer conflict scenario the load instruction is cancelled the store committed to memory from the store buffer and then the load re started In systems with an enabled MMU and where either the store buffer or load instruction targets an address undergoing PTE based translation the conflict detection is just performed on address bits 9 0 since higher order bits may be modified by translation and a conflict cannot be ruled out In other systems no MMU MMU disabled conflict detection is performed on the complete address Example st ld ad ld LDA a8 0xD000000E Address of un aligned load LDA al2 OxDO0000820 Circular Buffer Base LDA al3 0x00180014 Circular Buffer Limit and Index h al2 0x14 d7 Store causing conflict w d6 a8 Un aligned load split 16 16 d d4 d3 d2 Optional IP instruction d al2 al3 c dO dl Circular Buffer wrap 32 32 conflict with st h In this example the half word store is to address 0xD0000834 and is imme TC179 diately followed by a load instruction so is directed to the store buffer The 7 QS AC 18 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations word load from address OxDOOOOOOE is split into 2 half word accesses since it spans a 128 bit boundary in LDRAM The double word load encounter
122. ts on all instructions except the next to be executed then if this problem occurs the next instruction when single stepping will be the first instruction of the interrupt handler However if single stepping is implemented by setting a Break After Make BAM breakpoint on the next instruction to be executed or a BBM breakpoint on the next but one instruction the problem will not be visible In this case when single stepping the interrupt handler will be executed in its entirety before returning to the interrupted program flow and the breakpoint being taken after the next instruction to be single stepped Workaround As described previously this problem affects debug only and in this case the taking of the interrupt immediately upon exit from Halt mode cannot be avoided if the conditions to trigger the problem occur However the debugger single stepping functionality may be implemented in such a way that this problem does not directly affect the user as follows Upon first hitting a breakpoint the debugger should read and hold the current interrupt enable status from ICR IE Interrupts should then be disabled by setting ICR IE 0p If the next debugger action is to single step a BAM breakpoint should be placed on the next instruction to be executed and the CPU re started In this case a previously latched interrupt may be serviced but will not result in a further breakpoint being flagged until the interrupt handler returns and th
123. us access is used Workaround This error condition is avoided by increasing the address phase length or by adding another access phase i e address hold command delay or command wait between the address and burst phases of the access This will give the stored address values enough time to update TC1797 QS AC 96 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints FIRM_TC H000 Reading the Flash Microcode Version The 1 byte Flash microcode version number is stored at the bit locations 103 96 of the LDRAM address D000 000C after each reset and subject to be overwritten by user data at any time The version number is defined as Vsn contained in the byte as e s highest 4 bit hex number e n lowest 4 bit hex number Example V21 V23 V3A V3F etc FlexRay AI H002 Timer 1 Precision The relative timer is used to generate timing triggers based on the Macrotick counter If activated set bit TLC T1RC the timer waits for the first Macrotick increment signal to start its configured Macrotick counting This leads to an uncertainty of one Macrotick in single shot mode and for the first period in continuous mode For subsequent counting periods in continuous mode this kind of uncertainty does not occur and the precision of the timer signal increases to a single bclk cycle Workaround None FlexRay AI H003 Select upper lower page for IBF1 IBF2 in RAM test mode Each input buffer IBF1 IBF2
124. v 15ys 60us 40 C Vbpp 3 3v 470us 1 3ms 40 C Vopp 3 14v 520us 1 4ms Note LVDS settling time for higher temperatures remains within the limits defined above by 25 C Workaround In case of reset or if switching off then on the LVDS pad by software the PDR register should be programmed soonest possible for the LVDS pads to reach its stable level User has to take care that the communication is not started by the application software within the settling time period after enabling of LVDS in PDR register TC1797 QS AC 105 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Application Hints MSC _TC H009 Incorrect MSCO Interconnections specified in User s Man ual V1 1 Incorrect MSCO interconnections are specified in TC1797 User s Manual V1 1 table 22 31 Correct interconnections are e MSCO Input ALTINL 14 connected with OUT70 OG1 6 e MSCO Input ALTINL 15 connected with OUT71 OG1 7 Shall be corrected in future User s Manual release MultiCAN _AI H005 TxD Pulse upon short disable request If a CAN disable request is set and then canceled in a very short time one bit time or less then a dominant transmit pulse may be generated by MultiCAN module even if the CAN bus is in the idle state Example for setup of the CAN disable request CAN CLC DISR 1 and then CAN CLC DISR 0 Workaround Set all INIT bits to 1 before requesting module disable MultiCAN_ AI H006 Time stamp influenced by resynch
125. where at least the complete header of another frame is received before the frame received in slot N has been stored into the respective message buffer Effects Case1 Syntax error signalled for slot N correct behaviour no corruption Case2 Boundary violation signalled for slot N and slot N 1 Header and or payload of the message buffer assigned to slot N may be corrupted or frame received in slot N may be completely rejected Case3 No error signalled for slot N Frame received in slot N may be not stored or header of the message buffer assigned to slot N may be corrupted Corruption of the assigned message buffers payload may only occur when eray_bclk is below 25 MHz Workaround None TC1797 QS AC 61 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations FlexRay Al 085 Cycle filtering in slot 1 Description The message buffer for slot 1 is searched in parallel to every scan in the previous cycle A message buffer scan is started every 8th slot A running scan is aborted if the NIT is reached The message buffer used for slot 1 depends on the cycle filter configuration and the bus activity in the dynamic segment If the scan is aborted between the first and the last message buffer assigned to slot 1 it is unpredictable if the correct message buffer is used Scope The erratum is limited to the case where two or more message buffers are configured for slot 1 and cycle filtering is used Effects
126. y be used for offset correction term Description In case the temporal deviation time between primary time reference point and action point offset is different for channel A and B and the values have the following combination e greater than or equal zero on one channel and negative on the other channel e the channel with a relative deviation value greater than or equal zero is choosen for offset correction term calculation instead of the negative value Scope The erratum is limited to the case where both channels are used and if there is a large difference in the propagation delays on channel A and B Effects In case of the described relation between measured deviation values on channel A and B the calculated offset correction term may have an error of maximum the difference between the two deviation values Thus the error of the local time of the node is limited to the difference of the temporal deviation values of both channels TC1797 QS AC 49 115 Rel 1 4 25 01 2011 Infineon Errata Sheet Functional Deviations Workaround For dual channel FlexRay systems sync frames have to be transmitted on both channels In practice the propagation delay between two nodes is expected to be nearly the same on both channels If this is not the case the channel depending parameter pDelayCompensation A B GTUC5 DCA DCB has to be used to compensate the different propagation delays With a correct adjustment of the paramete