1. aSullard Frigitron 2000 Cool Climate Control Tube Instruction Sheet INCLUDES Frigitron 2000 and Belt FUNCTION The Frigitron 2000 is NIOSH approved to supply a continuous flow of cool air as part of Bullard supplied air respirator systems Please consult the NIOSH approval matrix in your respirator user manual to verify that the Frigitron 2000 is NIOSH approved for your specific configuration All Bullard parts must be present and properly assembled to constitute a NIOSH approved respirator NOTE Frigitron 2000 CAN be used with a low pressure air source such as Bullard ambient air pump Models ADP20 EDP30 and ICEPUMP11 Air Temperature Control Knobs CAUTION BEFORE USING THIS PRODUCT READ AND FOLLOW ALL DIRECTIONS AND WARNINGS INCLUDING THOSE IN THE RESPIRATOR INSTRUCTION MANUAL Figure 1 A WARNING Connecting the respirator to a line supplying Nitrogen or other harmful gases could cause death or serious injury Breathing Tube Quick Disconnect Air Quality Air Pressure and Air Supply Hose Length Requirements Air Quality A WARNING The respirator s air source must supply clean breathable air Grade D or better at all times The respirator does NOT purify air or filter out contaminants Respirable air must be supplied to the point of attachment of the BULLARD air supply hose The point of attachment is where the air supply hose connects to the fitting that con tains a pressure gauge
2. 5273 Tel 1 859 234 6616 Fax 1 859 234 8987 Europe Bullard GmbH Lilienthalstrasse 12 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 Asia Pacific Bullard Asia Pacific Pte Ltd LHK Building 701 Sims Drive 04 03 Singapore 387383 Tel 65 6745 0556 Fax 65 6745 5176 X S TES ISO 9001 certified 2014 Bullard All rights reserved 6088000321F 1014
3. BREATHING AIR PRESSURE TABLE in your respirator user manual defines the air pressure ranges necessary to provide the respirator with a volume of air that falls within the required range of 6 15 cubic feet per minute cfm or 170 425 liters per minute Ipm See 30 CFR Part II Subpart J 11 124 7 Be sure you understand the information in the BREATHING AIR PRESSURE TABLE before using the respirator Air Supply Hose To maintain your Bullard respirator s NIOSH approval use only approved Bullard V20 Series hose s in lengths of 25 300 feet between the Frigitron s quick disconnect fitting and the point of attachment to the hose Bullard quick disconnect fittings MUST be used to connect V20 hose lengths together Use of any other air supply hose voids the NIOSH approval on the entire respirator assembly and could reduce the airflow to the respirator possibly resulting in serious injury or death to the respirator wearer A WARNING Before connecting the Frigitron 2000 to the respirator be sure the breathing air at least meets the minimum Grade D requirements See Air Quality section on front page Frigitron 2000 Cool Climate Control Tube Instruction Sheet aSullard Preparation and Use of the Frigitron 2000 1 In an uncontaminated atmosphere screw the end of the breathing tube to the fitting on the climate control device Tighten hose connectors firmly 2 Lace the belt supplied with the Cool Tube through the belt brac
4. ket Pressure 3 With the approved Bullard V20 air supply hose connected to the air source and with Point of Gauge air flowing into the hose connect the quick disconnect coupler on the air supply hose to Attachment the quick disconnect nipple on the Frigitron 2000 4 Adjust the air pressure at the point of attachment to within the approved pressure range Figure 2 5 Put the hood on by following the directions in your respirator instruction manual If Respirator C4 aa e eda Bullard Customer Service at the address or Air Supply Grade D Hose Breathable 6 To obtain cooler air turn either or both of the air temperature control knobs Air Source clockwise Figure 1 Figure 2 Maximum cooling is attained when either or both knobs are fully open and when there is maximum airflow out of the Frigitron exhaust ports To obtain air that is closer to ambient temperature turn either or both air temperature control knob counterclockwise If both knobs are fully closed your respirator will receive air at ambient temperature 7 When finished working leave the work area wearing the respirator With the air still flowing into the hood remove the hood and then disconnect the air supply hose using the quick disconnect coupler attached to the Frigitron 2000 BUILD YOUR ullard www BuildYourBullard com Americas Bullard 1898 Safety Way Cynthiana KY 41031 9303 USA Toll free within USA 877 BULLARD 285
5. used to monitor the pressure of the air provided to you Locate the source of supplied air in a clean environment far enough from your work site to ensure the air remains contaminant free Always use an inlet filter on your air source and any monitors and alarms as necessary to assure clean breathable air at all times Supplied breathing air MUST meet or exceed the requirements for Type 1 gaseous air described in the Compressed Gas Association Commodity Specification G 7 1 Grade D or higher quality as specified by Federal Law 30 CFR Part II Subpart J 11 121 b The requirements for Grade D breathable air include Oxygen 19 5 23 5 Hydrocarbons condensed in mg m of gas 5 mg m max Carbon monoxide 10 ppm max Carbon dioxide ae ie ee 1 000 ppm max VUE ainean a EEA A EEE A AAA AAAA No detectable odor No toxic contaminants at levels that make air unsafe to breathe Refer to C G A Commodity Specification G 7 1 for complete details or contact the Compressed Gas Association 1235 Jefferson Davis Highway Arlington VA 22202 Air Pressure Continually monitor the air pressure at the point of attachment while operating the respirator A reliable air pressure gauge must be present to monitor the pressure A WARNING Failure to supply the minimum required pressure at the point of attachment for your hose length will reduce airflow and may expose you to life threatening conditions diseases or death The