1. 1 The chart is split into four sections which are discussed in the following sections of the document Note that the chart does not show all the detail of the process and is therefore not a replacement for the text in this document Customer emails RRF to ForthDD technical contact Return Required L u o u o a u e o a e al i Mii Supply RMA number and list items to be returned Acknowledge receipt and supply estimated return date I 3 l i I No I Reported fault Request more info More available i verified I l Yes no N l I Supply FAR and ship system i Yes l l l l I I I I I I I I I I I I I I I I I I I I I I Customer FDD I Supply FAR Supply FAR and Ship repaired or i pee return date estimate replaced system l I I I I I I I I I I I I I I I I I I I I I I I I I I Supply repair replacement quotation Ship system Send EF order Send repair replace order Supply Evaluation Fee quotation Figure 4 1 Returns process flow chart UM0008 Rev BA 2010 Forth Dimension Displays Ltd Page 6 of 16 FORTH DIMENSION DISPLAYS The returns process sections as shown in Figure 4 1 are Initial Consultation Return of System Fault Verification A A E Repair and Return 4 2 Initial Consultation All faults reported by customers must be made using an RMA Request Form RRF see section 5 This form is availab
2. 4 5 2 Customer Liability The customer is deemed liable for a returned faulty system if a the system is out of warranty b the fault has been caused by the customer thus invalidating the warranty The AA will supply an FAR and ForthDD Sales or the sales representative will contact the customer to supply a quotation for the repair work or replacement system if the system is considered beyond economical repair or is a display If the customer chooses to have the system repaired or replaced they will need to place an order with ForthDD Sales or with the representative If the system is returned out of warranty either through lapsing of the warranty period or voiding of the warranty and the customer chooses not to order a replacement or repair the customer will generally be charged an FF If the customer has not provided an order for the repair or replacement of the faulty system within 4 weeks of the quotation being supplied it will be assumed that the customer does not want to proceed with the repair or replacement In this case an EF will generally be charged and the system will be returned to the customer If an order is received then once the system has been repaired or a replacement has been obtained it will be returned to the customer and the AA will advise the customer of the shipping details If the system is to be repaired and there will be a delay before shipping the AA will supply an estimated shipping date Note that if d
3. Although ForthDD products feature ESD protection circuitry permanent damage may occur on devices subjected to high energy electrostatic discharges Therefore proper ESD precautions are recommended to avoid performance degradation or loss of functionality For further information regarding ESD handling precautions refer to IEC 61340 5 Part 1 amp 2 Protection of electronic devices from electrostatic phenomena General Requirements 2 2 Serviceable parts The product contains no user serviceable parts and it is recommended that you do not attempt to disassemble it otherwise the warranty may be invalidated UM0008 Rev BA O 2010 Forth Dimension Displays Ltd Page 4 of 16 FORTH DIMENSION DISPLAYS 3 Introduction Forth Dimension Displays ForthDD have developed a process for the return of systems which are thought to be faulty This document details the steps a customer should undertake if they believe they have a faulty system and how ForthDD will respond from the initial reporting of the fault by the customer through to any repair work and return of the system to the customer 1 Note that the term system is used throughout this document to refer to displays electronics or a combination of both UMO008 Rev BA O 2010 Forth Dimension Displays Ltd Page 5 of 16 FORTH DIMENSION DISPLAYS 4 Returns Process 4 1 Process Flow A simplified flow chart detailing how the returns process flows is shown in Figure 4
4. example if the problem is with the microdisplay then it might be determined that only the microdisplay should be returned However for some issues even if the fault appears to be with the microdisplay the whole system might need to be returned in order for ForthDD to undertake a full assessment of the problem The AA or AE will inform the customer what should be returned and will supply the customer with an RMA number 2 If the company has not had contact with a ForthDD AE the general technical support email address should be used tech support forthdd com or use the contact details given in section 8 UM0008 Rev BA 2010 Forth Dimension Displays Ltd Page 7 of 16 FORTH DIMENSION DISPLAYS D Note In general out of warranty displays should not be returned unless otherwise directed by the AA or AE as ForthDD do not repair displays The customer should return the system to ForthDD using their own courier service The system is under the responsibility of the customer while in transit Note the shipping documentation must contain the following statement Goods returned for investigation repair The customer may choose to supply their own reference number with the return as well as using the ForthDD RMA number Note that the ForthDD number remains the primary reference for the return although ForthDD will try and use the customer s reference alongside the ForthDD reference wherever possible An RMA number is only va
5. D DIMENSION 22 DISPLAYS Fault Analysis Report 1 RMA Number Prode pe Y D Paw Display S N YES NO Y ES al EPA Figure 6 1 Fault Analysis Report UMO008 Rev BA O 2010 Forth Dimension Displays Ltd Page 13 of 16 FAR Field Section 1 RMA number Section 2 Product type Electronics S N Display S N Customer ref no Section 3 Customer report Subsequent info Section 4 Reported fault confirmed Fault type Comments Recommended actions Liability UMO008 Rev BA FORTH DIMENSION DISPLAYS Table 6 1 FAR information Information required The number associated with the return This is the ForthDD product type e g SXGA R2 H1 The serial number of the returned electronics N A if none were returned The serial number of the returned display N A if none were returned Included if supplied by the customer The fault report supplied by the customer Any information supplied by the customer after the RRF was received Whether or not the fault reported by the customer could be reproduced This is the category that describes the fault found Any more detailed notes about the fault or investigation work Any follow up actions recommended by ForthDD This details who has financial responsibility for the return ForthDD or customer If the customer is paying an EF or paying for a replacement or repair then the liability is Customer 2010 Forth Dimension Displays Ltd Page 14
6. FORTH DIMENSION DISPLAYS Returns Process Document No UM0008 Revision BA Issued 9 February 2010 This drawing document is copyright and the property of Forth Dimension Displays Limited It must not be copied in whole or in part used for manufacture or otherwise disclosed without prior written consent Any copies of this drawing document made by any method must also include a copy of this legend Upon request this document shall be returned to the Quality Manager Uncontrolled copies of this document are available on request from the Quality Manager There shall be no exceptions to the terms and conditions set forth herein except as authorised by the Quality Manager Forth Dimension Displays Limited 7 St David s Drive St David s Business Park Dalgety Bay Fife KY11 9NB United Kingdom Telephone 44 0 1383 827 950 Fax 44 0 1383 827 951 E mail info forthdd com Website www forthdd com Copyright Forth Dimension Displays Limited FORTH DIMENSION DISPLAYS Contents o A OO 3 EU 9 16 hot abe nee E ee ee ne ee eee 3 Te A O 3 D DEE Fei na cy gare nee nee te eer AOS 3 tA lo o TI OCC oeeie a PE 3 Z Waminesa d NOUE Serege epoca ici aio 4 2M Electostatic RCA ONS ima foi 4 y ate lo AT A Pei O nO A 4 A A 5 t Reruns E TOS Siurana liada 6 A PROCESSES TION iento 6 12 ita Consultation Dti doce 7 do KO s E e o R TE A 7 4A cs A e io e a 8 da INE Ati ANG Reni D riire E TEN EE EEE EEE 9 A A o E bain sonuebe h
7. ade to ensure the accuracy of the information set out herein no warranty confirming such should be taken as having been given expressly or implied No freedom to use patents or other intellectual property rights is implied by the publication of this document Forth Dimension Displays Limited 7 St David s Drive St David s Business Park Dalgety Bay Fife KY11 9NB UK Forth Dimension Displays Limited is a company registered in England and Wales registered number 5220480 UM0008 Rev BA 2010 Forth Dimension Displays Ltd Page 16 of 16
8. applicable When noticed Was the fault detected when the system was first powered up Goods in or later In service Software ForthDD policy is to upgrade the code on the system to the latest factory upgrade standard configuration This will be done unless the customer enters No in which case the configuration will not be changed by ForthDD unless this is the only way to get the system working again or a CCN is entered in which case the system will be returned with configuration as detailed by that CCN Section 3 Fault symptoms Details of how the fault manifests itself The more detail given here the more likely ForthDD will be to confirm they can find the same fault as the customer Instructions Any details which specifically describe how or when the fault appears e g the fault only appears when the display is at 40 C or the flexi must be bent a certain way for the fault to appear no output from connector Jx when a specific item is connected Other notes Any other relevant information that the customer can supply about the fault or the system UM0008 Rev BA 2010 Forth Dimension Displays Ltd Page 12 of 16 FORTH DIMENSION DISPLAYS D 6 Fault Analysis Report FAR The FAR is used by ForthDD to detail information about the return to the customer The FAR is shown in Figure 6 1 An explanation of each part of the form is given in Table 6 1 Form FR0095 Revision AA FORTH jig eer B
9. ed in the shipping documentation If the system is determined to be faulty either with the reported fault or a different fault the process moves on to process section Repair and Return 45 Repair and Return O 4 5 1 ForthDD Liability ForthDD will take liability when a system is determined to be faulty and the system is in warranty The ForthDD AA will supply a Fault Analysis Report FAR for the return see section 6 and an estimated return date if the return is expected to run beyond the 10 working days aim As mentioned previously ForthDD do not repair displays so any faulty displays will be replaced by ForthDD ForthDD will repair electronics unless the fault is so major that the system is considered by ForthDD to be beyond economic repair in which case the system or part of it will be replaced The AA will email shipping details for the system when it leaves ForthDD Note that if display and electronics were returned together from the customer then they will generally be shipped back to the customer together from ForthDD For electronics the system configuration details will be included in the shipping documentation so that it is immediately obvious to the customer what the configuration is For the cases where the system is replaced the system that has been replaced by ForthDD will be scrapped by ForthDD UM0008 Rev BA 2010 Forth Dimension Displays Ltd Page 9 of 16 FORTH DIMENSION DISPLAYS D
10. eturn 4 4 Fault Verification O After return the system will undergo fault verification testing to confirm the fault is as reported by the customer and then to determine the cause of the fault If the reported fault cannot be verified the AA will contact the customer to ask for further information on how to recreate the fault 3 Completion is considered to be when the system ships back out from ForthDD UM0008 Rev BA 2010 Forth Dimension Displays Ltd Page 8 of 16 FORTH DIMENSION DISPLAYS D If there is no fault found NFF and the system is in warranty the system will be returned to the customer at ForthDD expense in most circumstances If the system is not in warranty or excessive return of NFF in warranty systems has occurred ForthDD may apply an EF to the return In this case ForthDD Sales or the sales representative will supply a quotation for the EF It is ForthDD s policy to upgrade all returned electronics systems including NFF systems to the latest factory standard versions of AP code FPGA code and add new versions of sequences if newer versions are available for those currently loaded If the customer does not want this to happen or has a Configuration Control Note CCN in place for the system in which case the system will be returned in this configuration then the appropriate section of the RRF should be completed see section 5 The configuration of the system if electronics will be includ
11. isplay and electronics were returned together from the customer then they will generally be shipped back to the customer together from ForthDD For electronics the system configuration details will be included in the shipping documentation so that it is immediately obvious to the customer what the configuration is For the cases where the system is replaced the system that has been replaced will be returned to the customer in the same shipment as the new system and will be listed in the shipping documentation as non conforming product UM0008 Rev BA 2010 Forth Dimension Displays Ltd Page 10 of 16 FORTH DIMENSION DISPLAYS D 5 RMA Request Form RRF The RRF must be used by customers to report issues they have with systems Completing the form correctly and fully with as much detail as possible will aid ForthDD s engineers and technicians in diagnosing the fault thus speeding up the whole returns process ForthDD will only accept systems back if an RRF is completed in advance of the return and an RMA number has been issued The RRF is available to download from the ASC section of the ForthDD website 3 The RRF is shown in Figure 5 1 with an explanation of what is required in each section given in Table 5 1 Form FR0091 Procedure UM0008 Revision AA Page 1of1 LD DIMENSION DISPLAYS RMA Request Form Display S N 3 A AP micro miero sode A E 2 ees source Analogue or DVI resolution a
12. le for download from the ForthDD Applications Support Centre 3 if you do not have a login for this site then please check before contacting your technical or sales contact within ForthDD that one has not already been issued to someone in your company as only one login is supplied per company Once completed the RRE should be emailed by the customer to ForthDD s supporting Application Engineer AE copying the customer s sales representative if sales are made via a representative The AE will consider the issue and in some cases discuss the reported fault with the customer in an attempt to solve the issue remotely or obtain more information about the issue If the AE determines that the system should be returned the process moves on to process section Return of System 4 3 Return of System Based on the information supplied on the RRF ForthDD will be able to determine whether the system is in warranty or not If the system is not in warranty the ForthDD Applications Administrator AA will inform the customer that the item is not in warranty and confirm whether the customer wishes to proceed with the return In some cases an evaluation fee EF may be applied to returns and the AA will supply details of what the current EF value is when EFs become applicable is discussed in sections 4 4 and 4 5 The customer can then decide whether to proceed with the return or not It may not be necessary to return a complete system For
13. lid for 30 days If the system it relates to is not returned within this period the RMA number will expire The AA will inform the customer when an RMA number has expired If the customer still wishes to return the system they will need to request a new RMA number This can be done by contacting the AA quoting the system serial number and previously supplied RMA number if possible The customer must ensure that the returning system is suitably packaged This is particularly important for the return of microdisplays as these are particularly susceptible to damage if incorrectly packaged Ideally return shipment should be made using the same packaging that the system was originally supplied in If the customer is in any doubt about the suitability of their packing material they should contact ForthDD The use of unsuitable packaging could invalidate the warranty Once the returned system has been received by ForthDD in Dalgety Bay UK the AA will acknowledge receipt of the system and supply an estimated completion date for the return It is the aim of ForthDD to complete the return of a system within 10 workings days of receipt at the ForthDD facility in Dalgety Bay This may not always be possible particularly in the case of systems that need to be repaired If there is a delay in the return of a system the AA will supply an updated expected completion date The customer should contact the AA with any requests for updates on the progress of a r
14. nd frame rate if applicable Was this a Since Goodsin Isere The system software and FPGA code will be upgraded to latest y do Nl a ce EA pe esa Other notes Figure 5 1 RMA Request Form UMO008 Rev BA O 2010 Forth Dimension Displays Ltd Page 11 of 16 FORTH DIMENSION DISPLAYS Table 5 1 RRF Information RRF Field Information required Section 1 The name of the company reporting the fault Contact name The name of the person reporting the fault This person will be the contact forman tangaa pat of tt ica bia The email address of the person reporting the fault The phone number of the person reporting the fault This is the date when the customer emails ForthDD the RRF Optional the customer may supply their own reference number Section 2 Product type This is the ForthDD product type e g SXGA R2 H1 if it is a modified nn version then the customer should note their project or programme name The serial number of the drive electronics if applicable The serial number of the display if applicable The AP micro code being used on the electronics FPGA code The FPGA code being used on the electronics if R2 then Dither FPGA code can be noted if known if applicable The sequence being used if applicable Whether DVI or analogue video is used and what the resolution and frame Video source rate are e g SXGA 60 for SXGA 1280x1024 resolution 60Hz frame rate if
15. ndanaseaany tte 9 DD AUF Oi 10 5 RMA Request Form RRF cta ia i 11 6 Faull Analysis Report FAR inrcr irn EE E E EEN 13 T Rev iom NIG LON A o UE E E E stair 15 S Comat Delano 16 UM0008 Rev BA 2010 Forth Dimension Displays Ltd Page 2 of 16 FORTH DIMENSION DISPLAYS 1 Preface 1 1 Purpose This document defines the process a customer should follow if they believe they have a faulty system The steps and responsibilities involved in a return are given 1 2 Scope This document details the return process for microdisplays and electronics 1 3 Disclaimer Please refer to the disclaimer on the last page prior to reading this document 1 4 Related Documents Table 1 1 Related Documents UMO004 SXGA Microdisplay Handling Guide UM0012 WXGA Microdisplay Handling Guide http www forthdd com support These documents are referenced throughout this document using square brackets UM0008 Rev BA 2010 Forth Dimension Displays Ltd Page 3 of 16 FORTH DIMENSION DISPLAYS D 2 Warnings and Notices The user should observe all of the precautions and warnings given in the SXGA Microdisplay Handling Guide 1 or WXGA Microdisplay Handling Guide 2 2 1 Electrostatic Precautions The microdisplay and associated hardware contain ESD Electro Static Discharge sensitive devices Electrostatic charges as high as 4kV readily accumulate on the human body and test equipment and can discharge without detection
16. of 16 7 Revision History Description of Change UMO008 Rev BA 11 2 08 18 2 08 18 3 08 17 10 08 9 2 10 FORTH DIMENSION DISPLAYS New document Minor changes Minor changes to H C and customer refs Changes to returning of goods and issuing of fault reports Introduction of CRF number expiry Major rework of process 2010 Forth Dimension Displays Ltd Page 15 of 16 8 Contact Details For further details please contact Forth Dimension Displays Limited 7 St David s Drive St David s Business Park Dalgety Bay Fife KY11 9NB United Kingdom Tel 44 0 1383 827 950 Fax 44 0 1383 827 951 Email info forthdd com Web www forthdd com FORTH DIMENSION DISPLAYS All performance figures and other data contained in this document must be confirmed in writing before they become applicable to any tender order or contract The Company reserves the right to make alterations or amendments to the information in this document and or product specifications at its discretion Forth Dimension Displays Limited does not accept liability for any loss or damage arising from the use of any information or particulars in this user manual or from any incorrect use of the product by unauthorised personnel All maintenance and service of the products must be authorised by Forth Dimension Displays Limited All reasonable skill and care has been taken in compiling this document Whilst every effort has been m