Installation & User Manual V2.02
Contents
1. Default the Controller See Restore Factory settings on page 11 The Controllers default IP address is 169 254 1 1 Set the Controller address to address 1 See page 11 for details Connect the Controller directly to a PC to using an ethernet cable Connecting the Controller directly to a PC using default IP address Connect an Ethernet cable between the Controller and the PC The default IP address of the Controller is set to 169 254 1 1 Set the IP address on the PC to a similar IP address e g 169 254 1 2 Note If there is no LED activity on your PC s ethernet interface then the PC requires a cross over cable between the PC and the Controller On the Controller tab Select TCP IP with Static option and enter the default Controller IP address of 169 254 1 1 and click apply The Controller icon will turn blue when it comes online A new IP address can then be sent to the Controller using the Controller TCP IP Configuration button Sending a new IP address to the Controller e g 192 168 1 26 Controller TCP IP Configuration button Choose Static IP mode and enter the IP address Netmask Default Gateway assigned by your IP Address network administrator Click Send new settings Netmask to Controller The Controller will now go offline as 22 the new IP Address settings are applied Connect the PC and Controller to your LAN and enter the new IP address to allow the application to communicate with the Contr
2. store the finger 2 print It uses algorithm to generate ca nn ee binary representation using sample points from the fingerprint It uses this information to then validate each users fingerprint lt Lj Finger Placement Wi BIO Finger Placement Wi BIO 1 Correct Finger Placement Incorrect Finger Placement Correct Incorrect Note Ensure that the finger is centered and Note Incorrect placement finger does not placed flat to the surface and fully covers the fully cover the sensor window sensor window The door control will not respond and the red light will not turn off if the sensor window Note Finger must remain on the sensor is not fully covered by the finger window until the door control acknowledges that the finger has been scanned by sounding a beep and turning off the red light This will take approximately 1 second
3. Controller UserGroups are created by combining pairs of DoorGroups with Timezones Each UserGroup can have up to 6 pairs of DoorGroups and Timezones Select DoorGroups and Timezones from the drop down menus to add to the current UserGroup Timezones are the periods of time for each day of the week that access will be granted Select times and tick the days of the week this time is valid 4 time periods can be created for each timezone Select Holiday Access to grant access for holiday periods Double click on the Holiday Access to add days to the holiday periods Use the calendar to select these days DoorGroups are created by grouping doors together e g all the entry and exit doors could be grouped together as Peremiter Doors Select a Door from the All available Doors window and drag it to the Doors in Current Door Group to add it to the Door Group Repeat for adding each door Phase 6 Downloading Configuration Step Descrtin After all users access levels and door control settings have been finalised a full download to the controller should be carried out Go to the Settings tab and click on Download Configuration A pop up window will appear tracking the status of the download All settings will be downloaded to the Controller and Door Controls Enrolling User FingerPrints Step Description E Note Make sure the USB Fingerprint reader is attached to the PC Select the Use
4. Scan Mode the Red Led on the Door Control will now be in flicker mode as an indication Repeat the process for all keypad Door Controls Enter Engineer mode on each Wi Bio Door Control in the following way Enter 6666 Enter 55 to default Scan Finger to confirm the Door Control will now go through the process of defaulting itself W hen this process has complete Scan Finger again to leave engineer mode and to put the Door Control in the Scan Mode the Red Led on the Door Control will now be in flicker mode as an indication Repeat the process for all W i Bio Door Controls Enter Engineer mode on each Prox Only Door Control in the following way A Adda programming card to the Door Control by presenting a card twice on power up The security wing must be removed first Present this new programming card to enter Engineer mode Present the programming card again to select Default mode Present any other card once to default the Door Control W hen this process has complete the Door Control will be in the Scan M ode the Red Led on the Door Control will now be in flicker mode as an indication The controller is now ready to allow Door Controls to enroll onto the Network click the Allow Doors to join this Controllers Network on the Controllers tab to start the controller scanning for new doors that do not already have an address only DoorControls without an address can enroll this will avoid other networks and Door Cont
5. Connect All Dip Switches OFF Network Diagrams i eTWOI grams for M ultiple Controller Em 12V RS485 Converter Controller 1 9 12V 1 E oV 2 Connect using RS232 RS485 S Rh cable to serial port on PC E Daisy Chain Set Baud Rate to 19200 Pena aller V PC Network Connections when using more than one GSD Controller Daisy chain the PC network A B OV to each controller Set an individual address for each controller between 1 amp 3 using the dip switches see below Controller 2 YIOMION Od Controller 1 Controller 2 Od Controller 3 Address 1 Set SW 1 ON Address 2 Set SW2 ON Address 3 Set SW3 ON il Network Diagrams Configuring GSD Controller Communications E Direct Connect All OFF Address 1 Set SW1 ON Address 2 Set SW 2 ON Note Address 3 Set SW 3 ON only Settings To restore the factory default setting Set ALL Dip Switches 1 2 3 amp 4 to the ON position and then power up the GSD Controller Example All Dip Switches are set to the ON position Note Factory Default settings will be restored after powering up the controller with All dip switches ON The dip switches s should then be set to the controller address as shown above in section Setting the GSD controller address Setting up TCP4P DHCP Step Description S i Default the Con
6. Other products from GSD Stand alone products global security devices GSO also offers fully functional standalone door controls for less complex door management This attractive design with modern aesthetics will complement any building 55D Digital C pt 050 a cO Gn Swit h GSD Biometric switch ae ee Features 50 users EE X scena Access control Multi format Door monitoring RFID reader p Manager user Installation Instructions Rire and intruder alarm interface PIN ACCESS Backlighting Tamper resistant 5 relays Indoor or outdoor use Robust polycarbonate housing with stainiess steel keys Mounts onto a Standard electrical Power 12v to 24 12v to 24 Rv 8 ew Mex Mex FingerPrint ACCESS ii Installation Diagrams ED IP Rating IP67 IP67 Cad THEE ipm n System Overview ED Wiring Diagrams ED Network Diagrams ED Operation Instructions Ry Fingerprint Enrollment 197 siobal security devices Wi Corporate Controller Technical Specs GSD Wi Corporate Controller Technical Specs Wi Corporate Door Controls Dimensions Flush Mount W 87mm D 35mm H 119mm Features Doors controlled 20 30000 128 128 128 Yes Yes Unlimited CCTV amp Lift control Supports W ireless amp RS485 Networks Automatic Backup Facility Databa
7. e enrolled onto the network go backto the Controller application and click the Secure Network button this safeguards the systems if you select another tab on the application this will happen automatically Select each Door on the application and configure individual settings such as Timed Actions Relay Times Ajar Times Door Option and Alarm Options etc IM PORTANT A timezone must be selected in Timed Actions for one of the options Card and PIN Any Card Card or PIN or PIN only If all of these are set to inactive then access will be denied for all cards and PINs on that Door Control Example Disabling cards fobs Enabling PIN codes only on a W i PIN amp Prox Set the Timed Action Card or PIN to Inactive and setting the Timed Action PIN Only to All dayEvery Day This will grant access for PIN codes and deny access for cards and fobs To enable or disable Timed Actions at specific times select a timezone from the drop down list instead of All Day Every day Enable a User by ticking the Enabled box for each User Assign a Name to the User Assign a UserGroup from the drop down menu The Usergroup will determine the access levels for this User Refer to section below on Configuring Access Levels for information on User Groups Assign a Card PIN number and enroll FingerPrints for the User Refer to section FingerPrint Enrolment on page 22 Click save to transmit these changes to the
8. h 10 meters 50 meters 50 meters Door Control 50 meters 50 meters Door Control 2 TCP4P connection to Controllers or RS485 Network to Controllers M ax number of Controllers 3 M ax Cable Length 1 4 km BENT Controller 2 3 50 meters Controller 1 50 meters Door Control 4 Door Control 50 meters Note Door Controls can be installed within 50 meters of the Controller or within 50 meters of any other Door Control as each Door Control will function as a repeater Each repeater transmits data to from the Controller Door Control 5 20 Kj Wiring Diagrams Network Diagrams ED Network Diagrams for Single Controller W iring Diagrams W arning Installation should only be carried out by a suitably qualified person only DB9 Female Serial Cable Cable Tie Cable Tie retaining clips L IEEE NOUS Connect DB9 cable to serial port on PC W 2 lt a 7 r1 2 Note Used ONLY for PC Network Connections Wired 485 Network can be used for multiple Connections I controllers See page I 10 for wiring Maximum cable length 10 meters NN gt NNW NVWNY S lt YIOMION PC Direct Connection can be used when OU oe E al o X XxX O using ONLY one GSD Controller Set the Direct address to ALL dip switches OFF see below Remove Battery Tab s nd no s ndu Direct
9. ntroller this gives the Controller a clean set of instructions before beginning to enroll doors onto the network This will take approximately 1 minute ARNING A New Network should only be created on first installation Creating a new network will overwrite any existing network information and any enrolled Door Controls will be un enrolled All Door Controls will have to be defaulted and re enrolled on the new network that has just been created A new network is now ready to be created Go to the Controllers tab and Click on the W ireless Network and then the Create a New Network button Click Yes on the Hit yes if you want to proceed pop up Note It will take about 20 60 seconds to complete a pop up will appear when the netwrok has been created Operation Instructions Operation Instructions Phase 3 Enrolling Door Controls Phase 3 Enrolling Door Controls Description S Ez Description E All Door Controls should be installed at this point and powered up All Door Controls must be defaulted before joining a network Note Door Controls will be shipped with their factory default settings Enter Engineer mode on each Keypad Door Control in the following way Press X followed by 6666 Enter 55 to default Press the tick to confirm the keypad will now go through the process of defaulting itself W hen this process has complete hit the X button to leave engineer mode and to put the keypad control in the
10. oller Note Reset the IP address on your PC to its original setting for your LAN Controller ep Ob Configuration Phase 1 Setting up the GSD Controller Step Description Description Install the main GSD Controller power up Default the controller immediately via the dip switch settings See instructions on page 11 Important Once powered up and the controller has completed the default the process reset the dip switches to the correct address positions See instructions on page 11 Follow instructions on the CD provided to install the GSD PC application To download the latest drivers enter the following link in your web browser http www globalsecurity ie download GSDW in Access en US zip Open the application A Log in to the application as the Engineer not the administrator with the password 6666 B Connect to the Controller Refer to page 12 amp 13 for setting up DHCP or Static IP addresses C The Controller icon will change colour to show that the Controller is ondine D Go to the Current Events tab and verify the log messages indicate the controller is ondine Open the Doors tab in the main menu to add the required number of new doors to be part of this network 1 door will already be added by default Click on the button to add new doors to remove doors M ake sure all doors are Enabled and then click Save Open the Settings Tab and do a Full Download to the Co
11. r for fingerprint enrollment Click on the Fingerprints button Click on Enrol tick box and place finger on the enrolment reader An image of the fingerprint will appear on the screen Ensure that the image quality is good and a value of at least 9096 is achieved Refer to section Finger Placement for correct finger placement and example of good quality image Repeat this process if this is not achieved on first attempt Click Save using a good quality template only Poor Quality templates can lead to false rejections later when trying to gain access 6 Finger Placement Wi BIO Finger Placement Wi BIO FE Correct Finger Placement Incorrect Finger Placement Note Incorrect placement finger does not fully cover the sensor window x Poor Quality Image the enrollment process This will increase Enrol succeeded Q 76 B x i i i 2 TC S the quality of the fingerprint template W Note Poor Quality image No Fingerprint S core on sensor window ii NON N Note Ensure that the core of finger is 5 centered the sensor window during Enrol succeeded 98 v Rd X Os Ay 2 4 n 4 Ji NN This can result in poor template quality that TAY can lead to false rejection issues later when MET __ Note Good Quality image Fingerprint core js 2 yy i N the user is trying to gain access is center of sensor window 22 Note The System does
12. rols in the same building on a different network becoming part of this new network Note For Wired 485 Door Controls right click on the Controller on the right hand side of the application and select M anually Assign Address from the drop down menu Once all new Door Controls are found by the Controller they will all beep with the number of the next available address door position on the Controller e g if door 2 is the next available address then all Door Controls will beep at the same time with 2 beeps This is basically saying that any door can be assigned to this address it s up to the installer to decide which one Also you will notice that the Key back light of the keypad Door Controls will be illuminated with the next available address as well i e Key 2 will be illuminated for this example Go to the Door control that you want to make door 2 on the network system it should be beeping 2 times Press any key on this keypad and the system will automatically assign this door control to door 2 location on the system Present a card if the Door Control is Prox Only Note All other Door Controls will now start beeping with the next available address i e 3 beeps in this instance and so on every time you enroll a new Door Control The Key back light will also correspond to each address as the system fills up Phase 3 Enrolling Door Controls Step Description ___ o Once all Door Controls ar
13. se Encryption 30000 individual usergroups are available Installation Steps Step Description Page Install the Controller using the Installation Diagrams W ire the Controller using the W iring Diagrams m Install and wire each Door Control Refer to the Door Control B Manual for instructions 4 Connect the Controller to the PC using Network Diagrams 9 11 Restoring Factory Defaults Setting up TCP IP 6 o prm I Installation Diagrams EE Control Panel opening Control Panel features cable entr access to rear y mount with 4 x15 inch mount hole void for wiring No 8 Security Type screws remove screw cap remove retaining screw cable rear tamper Switch to remove cover mount hole mount hole pull forward on right and slide left Note If using a single Controller an RS232 cable may be used Max cable length 10 meters Place a 120o0hm Termination Resistor across A amp B on the Controller TCP IP connection to Controllers or RS485 Network to Controllers Max number of Controllers 3 Max Cable Length 1 4 km BEN Controller 2 3 Controller RS485 Network to Door Controls M ax Cable Length 1 4 km Daisy Chain Configuration Only Door Control Door Control Place a 120o0hm Termination Resistor across A amp B on the last Door Control in the chain Door Control 4 20 Door Control Note If using a single Controller an RS232 cable may be used Max cable lengt
14. troller See Restore Factory settings on page 11 The default TCP IP mode will then be set to DHCP Set the Controller address to address 1 See page 11 for details Connecting the Controller to yur DHCP LAN Connect the Controller to your LAN using an ethernet cable The Controller will be assigned an IP address by your DHCP server On the Controller tab Select TCP IP with the DHCP option and enter the MAC address of the Controller The MAC address of the controller can be found on the box or on the Controller PCB The Controller icon will turn blue when it comes online ge MAC Address 00 50 C2 BD 40 XX Connecting the Controller directly to a PC using default IP address Connect an Ethernet cable between the Controller and the PC The default IP address of the Controller is set to 169 254 1 1 Set the IP address on the PC to a similar IP address e g 169 254 1 2 Note If there is no LED activity on your PC s ethernet interface then the PC requires a cross over cable between the PC and the Controller On the Controller tab Select TCP IP with DHCP option and Enter the MAC address of the Controller or Select TCP IP with Static IP option and enter the default Controller IP address of169 254 1 1 and click apply connection 00 50 C2 BD 40 XX 169 254 1 1 Type TCP IP Settings Type TCP IP Settings Seria Static IP Serial Static IP DHCP Controller TCIVIP Gonfgyration ee O lb Using MAC Address Using Default IP Address
Download Pdf Manuals
Related Search
Related Contents
Installation manual for wired remote controller BaculoDirect GST Gateway Expression Kit Weckradio - Gt Nostalgic Warehouse 703411 Instructions / Assembly USER`S MANUAL - Sears PartsDirect Manual de Instalación Manuale Utente - Professional Sound Light Professional Sound Light dossier enseignant Elémentaire - IME Thuraya SatSleeve Ti125 et Ti110 et Ti105 Usage général : Ti100 Copyright © All rights reserved.