1. If the DMX signal is lost or power is applied the unit will automatically go into Master Slave mode a NY oii Blackout If the DMX signal is lost or power is applied the unit will automatically go into stand by mode e LASI Last State If the DMX signal is lost the fixture will stay in the last DMX set up If power is applied and this mode is set the unit will automatically go into the last DMX set up Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 11 TVL1000 System Menu 3 Press ENTER to confirm your desired set up LELI With this function you can have the LED display turn off after 20 seconds 1 Press the MENU button until LED is displayed press ENTER 2 The display will show either UN or DFF Press the UP or DOWN buttons to select 0N to keep the LED display On at all times or UFF so that the LED display turns off after 20 sec onds 3 Press ENTER to confirm Nor This function will reverse the display 180 1 Press the MENU button until ISP is displayed press ENTER 2 Press the UP button to select USIP to activate this function or USP to deactivate this function 3 Press ENTER to confirm IMTI This function is used for battery charging 1 Press the MENU button until BATT is displayed press ENTER 2 Either CHAR LOAD or STAT will be displayed Use the UP or DOWN but
2. Rev 2 13 User Instructions TVL1000 General Information Unpacking Thank you for purchasing the TVL1000 by Elation Pro fessionals Every TVL1000 has been thoroughly tested and has been shipped in perfect operating condition Carefully check the shipping carton for damage that may have occurred during shipping If the carton appears to be damaged carefully inspect your fixture for any damage and be sure all equipment necessary to operate the unit has arrived intact In the event damage has been found or parts are miss ing please contact our toll free customer support number for further instructions Please do not return this unit to your dealer without con tacting customer support first Introduction The TVL1000 DMX intelligent LED fixture The TVL1000 has 3 DMX Modes Two 2 Channel Modes and a 3 Channel Mode The fixture has two operating modes manual mode or DMX controlled The TVL1000 can only be run as stand alone unit This unit is suitable for theaters studios retail stores and other similar locations For best results use fog or special effects smoke to enhance the light projec tions Customer Support Elation Professionals provides a toll free cus tomer support line to provide help and to answer any question should you encounter problems during your set up or initial operation You may also visit us on the web at www elationlighting com for any com ments or suggestions Service Hours are Monday through Friday 8 00
3. a m to 4 30 p m Pacific Standard Time Voice 323 582 3322 Fax 323 832 9142 E mail support elationlighting com To purchase parts online visit http parts elationlighting com Warning To prevent or reduce the risk of electrical shock or fire do not expose this unit to rain or moisture Warning This may cause severe eye damage Avoid looking directly into the light source at all times Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 2 TVL1000 To optimize the performance of this product please read these operating instructions carefully to familiarize yourself with the basic operations of this unit These instructions contain important safety information regarding the use and maintenance of this unit Please keep this manual with the unit for future reference TVL1000 Features 3 DMX Channel Modes Two 2 Channel Modes amp 3 Channel Mode 2 Operating Modes Manual Mode amp DMX Control Digital Display for Address and Function Setting e Power Cord Daisy Chain General Instructions TVL1000 The TVL1000 carries a 2 year 730 days limited warranty Please fill out the enclosed warranty card to validate your purchase and war ranty You may also register your product online at www elationlight ing com All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number If the unit is under warranty you mus
4. 0 comes with an easy to navigate system menu To access the main menu press the MENU button Tap the UP or DOWN buttons until you reach function you wish to change When you reach the function you wish to change press the ENTER button When a function is selected use the UP or DOWN buttons to change the func tion settings Once your changes are made press the ENTER button and then press and hold the MENU button for at least three seconds to confirm and lock the change into the system memory If the MENU button is not pressed and held within eight seconds the fixture will automatically confirm and lock the change into the system memory To exit without making any changes press the MENU button LL DMX Address Setting 1 First set the unit to your desired DMX Channel mode 2 To set your address tap either the MENU UP or DOWN buttons until ADOR is displayed press ENTER will now be displayed and flashing 3 Press the UP or DOWN buttons to find your desired address When you have found your desired DMX address press ENTER and connect your DMX Controller LANL This will let you switch between the 3 DMX Chan nel Modes 1 Press the MENU button until LANO is displayed press ENTER Either OL i 2 Channel Mode iui 2 2 Channel Mode or Mut 3 3 Channel Mode will be displayed 2 Press the UP or DOWN buttons to choose your desired DMX mode and press ENTER to confim and exit Pit In this
5. Distance m Q 1 0 2 0 3 0 4 0 5 0 Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 15 TVL1000 Power Cord Daisy Chain Powered via power outlet With this feature you can connect the fixtures to one another using the IEC input and output sockets The quantity that can be connected is 12 fixtures maximum After 12 fixtures you will need to use a new power outlet They must be the same fixtures DO NOT mix fixtures Powered via battery power With this feature you can connect the fixtures to one another using the IEC input and output sock ets The quantity that can be connected is 5 fixtures maximum After 5 fixtures you will need to use a new power outlet They must be the same fixtures DO NOT mix fixtures NOTE Powered via battery does not mean that 5 fixtures are being powered by one battyer each unit must have a battery connected Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 16 TVL1000 Battery Installation The TVL1000 can also be powered by battery Part TVL 1000Bat not included Connecting the battery is a very simple procedure Follow the instructions below to connect the battery 1 Start by unscrewing and removing the thumb screws that hold the panel in place 2 Once the panel has been removed connect the battery to the battery wire located inside the unit 3 When the battery has been connected simply slide the battery i
6. a few common problems that you may encounter with solutions No light output from the unit 1 Be sure the external fuse has not blown The fuse is located on the rear panel of the unit 2 Be sure the fuse holder is completely and properly seated Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 18 TVL1000 2 YEAR LIMITED WARRANTY Warranty A Elation Architectural hereby warrants to the original purchaser Elation Professionals products to be free of manufacturing defects in material and workmanship for a period of two years 730 days from the date of purchase This warranty shall be valid only if the product is purchased within the United States of America including possessions and territories It is the owner s responsibility to establish the date and place of purchase by acceptable evidence at the time service is sought B For warranty service send the product only to the Elation Professionals factory All shipping charges must be pre paid If the requested repairs or ser vice including parts replacement are within the terms of this warranty Ela tion Professionals will pay return shipping charges only to a designated point within the United States If the entire instrument is sent it must be shipped in its original package No accessories should be shipped with the product If any accessories are shipped with the product Elation Professionals shall have no liabil
7. al Note Line Termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behavior A terminator is a 90 120 ohm 1 4 watt resistor which is con nected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line Using a cable terminator ADJ part number Z DMX T will decrease the possibilities of erratic behavior Termination reduces signal errors and avoids signal transmission problems and interference It is always advisable Z X 5 to connect a DMX terminal Resistance 120 Ohm 1 4 W between PIN 2 DMX and PIN 3 DMX of the last fixture Figure 4 Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 6 TVL1000 T a o TVL1000 Control Panel 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for DATA transmission in place of 3 pin 5 pin XLR fixtures 220o may be implemented in a 3 pin XLR DMX line When inserting stan dard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used these adaptors are readily available at most electric stores The chart below details a proper cable conversion 3 Pin XLR to 5 Pin XLR Conversion T 6 3 Pin XLR Female Out 5 Pin XLR Male In 1 Display To show the various menus and the selected functions 2 Indicator LED First make sure to turn on the battery sw
8. before making any type of connection Do not remove the cover under any conditions There are no user serviceable parts inside Never operate this unit when it s cover is removed Always be sure to mount this unit in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if it becomes damaged This unit is intended for indoor use only use of this product out doors voids all warranties Always mount this unit in safe and stable matter Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords at plugs convenience recep tacles and the point where they exit from the appliance Cleaning The fixture should be cleaned only as recommended by the manufacturer See page 18 for cleaning details Heat This fixture should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that produce heat The fixture should be serviced by qualified service personnel when A Objects have fallen or liquid has been spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or exhibits a marked change in performance Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 4 TVL1000 Set Up Power Sup
9. equipment must be installed by a professional and it must be 7 DMX input For DMX512 link use 3 5 pin XLR plug cable to input DMX signal installed in a place where it is out of the reach of people s grasp 8 Main input Connect to main power supply 9 Main output Connect to the main power ofthe next unit Battery switch Turn on or turn off the switch for battery mode This switch can only control battery Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 7 Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 8 TVL1000 System Menu l Addr H TE DMX512 Address Setting Hoo Chid fodd Channel Mode Mods Led in _ T daw tea Manual setting dm Les NASL MENU dG o LNa DMX state LASE EF an LED Display Always On off LED Display Off a5 1p Inversion Lheor com odtt Lodd OFF Battery state Gleidit EGE Self test FHS Fixture Hours ufr Software Version Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 9 TVL1000 System Menu System Menu The TVL100
10. itch MASTER Master Mode Data True signal Pin 3 Not Used a Pin 5 Do Not Use BATTERY Battery is full Note Connect the fixture to a main power supply If the battery indicator blinks slowly it means the battery is being charged When the indicator stops blinking and stays lit it means the battery is at full charge When using the battery power the indicator light will not bet lit If the remaining battery power is less then 16 the indicator will blink fast reminding you that the battery is low and that it needs to be charged The TVL1000 is fully operational in three different mounting positions 3 Button hanging upside down from a ceiling hanging sideways on truss ing or set on a flat level surface The unit should be mounted using a mounting clamp not provided affixing it to the mounting bracket that is provided with the unit Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is 4 Dimmer adjust knob Adjust lightness for the unit from 0 100 able to support a weight of 10 times the unit s weight Also always 5 Color temperature adjustment Adjust the color temperature from 3200k to 6500k use a safety cable that can hold 12 times the weight of the unit when 25K as a step installing the fixture DMX output For DMX512 link use 3 5 pin XLR plug cable to link the next unit 6 The
11. ity whatsoever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number has been altered or removed if the product is modified in any manner which Elation Professionals concludes after inspection affects the reliability of the product if the product has been repaired or serviced by anyone other than the Elation Professionals factory unless prior written authorization was issued to purchaser by Elation Profes sionals if the product is damaged because not properly maintained as set forth in the instruction manual D This is not a service contract and this warranty does not include mainte nance cleaning or periodic check up During the period specified above Ela tion Professionals will replace defective parts at its expense and will absorb all expenses for warranty service and repair labor by reason of defects in mate rial or workmanship The sole responsibility of Elation Professionals under this warranty shall be limited to the repair of the product or replacement thereof including parts at the sole discretion of Elation Professionals All products covered by this warranty were manufactured after January 1 1990 and bear identifying marks to that effect E Elation Professionals reserves the right to make changes in design and or improvements upon its products without any obligation to include these changes in any products theretofore man
12. mode you can manually adjust the LED intensity to create your desired color temperature Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 10 TVL1000 System Menu 1 Press the MENU button until MANU is displayed press ENTER LEDI LEU or LINN will be displayed LED 1 is warm white LED 2 is cool white and DIMM is the master dimmer for this mode 2 Use the UP or DOWN buttons to scroll to the color you would like adjust first and press ENTER 3 Use the UP or DOWN buttons to adjust the intensity of the chosen color and press ENTER after the adjustment 4 Continue to make adjustments to the two colors until your desired color is reached Once your desired color is reached do not leave this mode 5 To leave this mode press the MENU button Once you leave this mode all settings will be reset i oT 11 This mode can be used as a precaution mode that in case the DMX signal is lost the operating mode chosen in the setup is the running mode the fixture will go into when the DMX signal is lost You can also set this as the operat ing mode you would like the unit to return to when power is applied 1 Press the MENU button until ONST is displayed press ENTER 2 Either NASL SLND or LAST will be displayed Choose an operating mode you would like the unit to start up in when power is applied or the DMX signal is lost e fist Master Slave
13. nnel Modes 2 Channel Mode 2 Channel Mode amp 3 Channel Mode Sound Active Yes Working Position Warranty Any Safe Secure Position 2 Year 730 days Please Note Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice Auto Sensing Voltage This fixture contains a electronic bal last which will auto sense the voltage when it is plugged into the power source Elation Professionals A Division of the AmericanDJ Group of Companies World Headquarters 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 3322 Fax 323 832 9142 Web www elationlighting com E mail info elationlighting com American DJ Europe Junostraat 2 6468 EW Kerkrade Netherlands service americandj eu www americandj eu Tel 31 45 546 85 00 Fax 31 45 546 85 99
14. nto the compart ment and secure using the pop up thumb screws Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 17 TVL1000 Fuse Replacement First unplug the power Locate and remove the unit s power cord Once the cord has been removed located the fuse holder located inside the power socket Insert a flat head screw driver into the power socket and gently pry out the fuse holder Remove the bad fuse and replace with a new one The fuse holder has a built in socket for a Spare fuse be sure not to confuse the spare fuse with active fuse TVL1000 Cleaning Fixture Cleaning Due to fog residue smoke and dust cleaning the internal and external optical lenses and mirror should be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates l e smoke fog residue dust dew In heavy club use we recommend cleaning on a monthly basis Periodic cleaning will ensure longevity and crisp out put 1 Use normal glass cleaner and a soft cloth to wipe down the out side casing 2 Use a brush to wipe down the cooling vents and fan grill 3 Clean the external optics and mirror with glass cleaner and a soft cloth every 20 days 4 Clean the internal optics with glass cleaner and a soft cloth every 30 60 days 5 Always be sure to dry all parts completely before plugging the unit back in TVL1000 Trouble Shooting Listed below are
15. ply The Elation Professionals TVL1000 contains an electronic ballast which will auto sense the voltage when it is plugged into the power source With the electronic ballast you do not need to worry about wall voltage this unit can be plugged in anywhere Also be sure to only use the included E C power cable supplied with the unit DMX 512 DMX is short for Digital Multiplex This is a universal pro tocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions from the controller to the fix ture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a DATA OUT terminal DMX Linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a sin gle controller as long as all fixtures and the controller are DMX com pliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows
16. rol Universal DMX Control This function allows you to use a Elatione universal DMX 512 controller to create unique programs tailored to your individual needs 1 The TVL1000 has three DMX channel modes To set the chan nel mode see page 10 See page 15 for the DMX modes amp traits 2 To control your fixture in DMX mode follow the set up procedures on pages 5 7 as well as the set up specifications that are included with your DMX controller Use the controller s faders to control the various DMX fixture traits This will allow you to create your own programs Follow the instructions on page 10 to set the DMX address For longer cable runs more than a 100 feet use a terminator on the last fixture 7 For help operating in DMX mode consult the manual included with your DMX controller P pi epa Manual Mode This mode allows the user to adjust the color intensity to create their own desired color temperature 1 Press the MENU button until MANU is displayed and press ENTER 2 Follow the instructions on pages 10 11 to operate this mode 3 You can also use the Color Adjust Knob and Dimmer Knob to manually create your desired color temperature Please see the Control Panel on page 8 Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 14 TVL1000 DMX Modes 100 0 TVL1000 Photometric Chart 3200K i 6500K van 4850K
17. t provide a copy of your proof of purchase invoice Please contact Elation customer support for a R A number Warranty Registration TVL1000 Handling Precautions Caution There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will void your manufactures war ranty In the unlikely event your unit may require service please contact Elation Professionalse During operation the housing may become hot Avoid touching the unit with bare hands while in use Elation Professionalse will not accept any liability for any resulting dam ages caused by the non observance of this manual or any unauthor ized modification to this unit Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 3 TVL1000 Safety Precautions For Your Own Personal Safety Please Read and Understand This Manual Completely Before You Attempt To Install Or Operate This Unit To reduce the risk of electrical shock or fire do not expose this unit rain or moisture Do not spill water or other liquids into or on to your unit Be sure that the local power outlet match that of the required volt age for your unit Do not attempt to operate this unit if the power cord has been frayed or broken Do not attempt to remove or break off the ground prong from the electrical cord This prong is used to reduce the risk of electrical shock and fire in case of an internal short Disconnect from main power
18. to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX and Master Slave Operation The TVL1000 3 DMX channel modes The DMX address is set electronically using the controls on the side of the unit Your unit and your DMX controller require a approved DMX 512 110 Ohm Data cable for data input and data output We recommend Accu Cable DMX cables If you are making your own cables be sure to use standard 110 120 Ohm shielded cable This cable may be purchased at almost all professional sound and lighting stores Your cables should be made with a male and female XLR connector on either end of the cable Also remember that DMX cable Figure 1 p must be daisy chained and cannot be split Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 5 TVL1000 Set Up Notice Be sure to follow figures two and three when making your own cables Do not use the ground lug on the XLR connector Do not con nect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behavior COMMON Figure 2 Pin 3 Data True positive l XLR Male Socket XLR Female Socket XLR Pin Configuration l l 1 1 Ground 1 l l Pin 2 Data Compliment negative I I I I l l Figure 3 Speci
19. tons to scroll through the functions and press ENTER to select your desired function e CHAR Charging When this is selected you are able to charge or ape charging the battery When a power cable is connected and ON is selected the battery is now being charged To stop charging select OFF Unt LED On or OFF This will let you blackout the LED while L Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 12 TVL1000 System Menu charging Select OFF to blackout the LED or ON to stop the LED blackout e STHt Charge Status This will let you check the battery status 3 Press ENTER to confirm your setting and exit IE This function will run a self test program 1 Tap the MENU button until EST is displayed press ENTER 2 The fixture will now run a self test program To stop the self test press either the MENU or ENTER button F nS With this function you can display the running time of the unit 1 Press the MENU button until FARS is displayed press ENTER 2 The display shows the running time of the unit Press MENU to exit VE ER R Use this function to display the Software version of the unit 1 Press the MENU button until VER is displayed press ENTER 2 The display will show the software version Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 13 TVL1000 Universal DMX Cont
20. ufactured F No warranty whether expressed or implied is given or made with respect to any accessory supplied with products described above Except to the extent prohibited by applicable law all implied warranties made by Elation Profession als in connection with this product including warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no war ranties whether expressed or implied including warranties of merchantability or fitness shall apply to this product after said period has expired The consumer s and or Dealer s sole remedy shall be such repair or replacement as is expressly provided above and under no circumstances shall Elation Professionals be liable for any loss or damage direct or consequential arising out of the use of or inability to use this product G This warranty is the only written warranty applicable to Elation Profession als Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published Elation Professionals www elationlighting com TVL1000 Instruction Manual Page 19 TVL1000 Specifications TVL1000 100 240V 50 60Hz 400 LEDs 200 Cool White amp 200 Warm White Power Consumption 26W Fuse TA Power Cord Daisy Chain 12 Fixtures Max 15 9 L x 13 7 W x 4 4 H 406mm x 350mm x 113mm 13 6 Lbs 6 2 kgs Cool White amp Warm White None 3 DMX Cha

Download Pdf Manuals

image

Related Search

Related Contents

Engine Diagnostic Equipment  复件 Q-Spot_260-LED_UM3 - Hosen lighting technology limited  Téléchargement  Le service DMT, mode d`emploi De vrais + au quotidien - Infos  (Microsoft PowerPoint - mode d`emploi Filpost.ppt [Mode  シキミの栽培技術指針−仁淀川流域  取扱説明書 取扱説明書に関するご注意 安全上のご注意 警告 注意 電波  LES MARCHES TRANSITIONNELS DU TRAVAIL  Panasonic MC-UG471 vacuum cleaner  rapport narratif - Centre d`Echange d`Information sur la Biodiversité  