1. the Patton Model DB 25 to Your PC Modem or Printer APPENDIX A PATTON MODEL 503S SPECIFICATIONS Lines Protected Power Handling Clamp Voltage Grounding Capacitance Protects 24 lines on the DB 25 serial interface Peak combined power handling up to 36kW 1 5kW per wire 10 x 1000uSec in Compliance to IEC 801 5 Level 3 2 kV 27 Volts Surge energy diverted to chassis ground through pin 1 and metal D shell Alternate ground connection for Model 503P provided by external grounding wire less than 500pF Cable Length Burden less than 9 1 2 8m Surge Capacity IEC 801 5 Level 3 2kV Copyright 1997 Patton Electronics Company OOOOOMAI Rights Reserved 5 Notes Dear Valued Customer Thank you for purchasing Patton Electronics products We do appreciate your business I trust that you find this user manual helpful We manufacture one of the widest selections of data communications products in the world including CSU DSU s network termination units powered and self powered short range modems fiber optic modems interface converters baluns electronic data switches data line surge protectors multiplexers transceivers hubs print servers and much more We produce these products at our Gaithersburg MD USA facility and can custom manufacture products for your unique needs We would like to hea
2. USER MANUAL MODEL 503S Serial Surge Protector goni MODEL 5935 _ SERIAL DB 25 SURGE PROTECTOR PE PATTON M ElectronicsTo ISO Part 07M503S D SALES OFFICE Oy en U 301 975 1000 ev Paine Revised 1 21 08 TECHNICAL SUPPORT 301 975 1007 An 150 900 http www patton com Certified Company 1 0 WARRANTY INFORMATION Patton Electronics warrants all Model 503S components to be free from defects and will at our option repair or replace the product should it fail within one year from the first date of shipment This warranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modification If this product fails or does not perform as warranted your sole recourse shall be repair or replacement as described above Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product These damages include but are not limited to the following lost profits lost savings and incidental or consequential damages arising from the use of or inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 503S Series units generate and use radio frequency energy and if not installed and used properly that is in st
3. e obtained from Patton Electronics Technical Support 301 975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepted Patton Electronics technical staff is also available to answer any questions that might arise concerning the installation or use of your Patton Model 503S Technical Service hours 8AM to 5PM EST Monday through Friday 2 0 GENERAL INFORMATION Thank you for your purchase of this Patton Electronics product This product has been thoroughly inspected and tested and is warranted for One Year parts and labor If any questions arise during installation or use of the unit contact Patton Electronics Technical Support at 301 975 1000 2 1 PRODUCT DESCRIPTION The Patton Model 503S guards all pins on the DB 25 serial interface against data loss and damage due to transient surges The Model 503S employs a solid state circuit using Silicon Avalanche Diodes and has a combined surge handling capacity of up to 36 000 Watts 1 5kW per wire Connecting directly between the DB 25 serial port of your hardware PC modem or printer and the serial cable the Model 503S diverts surge energy to chassis ground through pin 1 and the metal D shell For complete protection of your serial line we recommend that one surge protector be used at each end of the line Warning These products will not provide complete protection should your equipment be subject to a direct lightn
4. ing hit 2 2 SURGE PROTECTION BENEFITS The method of surge protection used in the 503S adds four benefits to your system 1 High Surge Capability The 503S handles up to 36k Watts 1500 Watts per wire of surge energy 2 Quick Response The 503S feature a response time of 500 nsec with transient surges being clamped at 27 Volts 3 Low Impedance Connect the 503S directly to RS 232 ports with minimal load to your system about the same as a gender changer 4 Fail Safe Design Unlike some other surge suppressors the 503S fails short to ground should your system experience an excessive surge 3 0 INSTALLATION Patton s Model 503S is simple to install and requires no user configuration Follow these installation steps 1 Turn your equipment s power switch off and disconnect the power cord from the wall outlet 2 Unplug disconnect the existing connection between the serial cable and your DB 25 serial port 3 Install the Model 503S between the serial cable and the DB 25 serial port If the D shell is not connected to chassis ground use the grounding wire included to make an alternate frame ground connection Proper grounding is essential to the operation of the Model 5035 O a Alternate Ground Connections O i A DE PATTON Zlectronics To MODEL 503S SERIAL DB 25 SURGE PROTECTOR E IT Figure 1 How to Connect
5. r from you Please contact us in any of the following ways to tell us how you like this product and how we can meet your product needs today and in the future Web http www patton com Sales E mail sales patton com Support E mail supportOpatton com Phone Sales 301 975 1000 Phone Support 301 975 1007 Fax 301 869 9293 Mail Patton Electronics Company 7622 Rickenbacker Drive Gaithersburg MD 20879 USA We are committed to a quality product at a quality price Patton Electronics is ISO 9001 certified We meet and exceed the highest standards in the industry CE UL etc It is our business to serve you If you are not satisfied with any aspect of this product or the service provided from Patton Electronics or its distributors please let us know Thank you Burton A Patton Vice President P S Please tell us where you purchased this product
6. rict accordance with the manufacturer s instructions may cause interference to radio and television reception They have been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If these products do cause interference to radio or television reception which can be determined by turning off the unit the user is encouraged to try to correct the interference by one or more of the following measures moving the computing equipment away from the receiver re orienting the receiving antenna and or plugging the receiving equipment into a different AC outlet such that the computing equipment and receiver are on different branches 1 2 CE NOTICE The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility EMC directive and the Low Voltage Directive LVD of the Union European EU A Certificate of Compliance is available by contacting Technical Support 1 3 SERVICE All warranty and non warranty repairs must be returned freight prepaid and insured to Patton Electronics All returns must have a Return Materials Authorization number on the outside of the shipping container This number may b
Download Pdf Manuals
Related Search
Related Contents
Atlas ZEN User Guide - Peak Electronic Design Limited Kenmore 596.760627 Refrigerator User Manual SR192 Development System v3.0 User Manual AEG X69453MV0 cooker hood RouterBOARD 1100 HC-V520M HC-V510 Desa (V)JM50 User's Manual Creating New Artificial Life Garmin 10V Installation Instructions Copyright © All rights reserved.