S2000-V Instruction Manual
Contents
1. by means of supplied screw and screw nut In case of being applied to protect steel safe or ATM unit deposit box paste S2000 V with the help of glue SECURITY SYSTEMS DETECTOR WIRING DIAGRAM SENSITIVITY ADJUSTMENT CONTROL TAMPER SWITCH 2 WIRE a E 2 WIRE COM LINE LINE re DETECTOR ADJUSTMENT HOW TO SET THE DETECTOR NET ADDRESS Connecting a S2000 V detector to a two wire controller it is necessary to assign it with a unique address number identifying the S2000 V within the two wire line Net address is stored in the detector non volatile memory A S2000 V detector is delivered with preset address value of 127 In order to change the network address connect the S2000 V to a PC through the S2000 KDL and any RS 485 interface converter supplied with UPROG program The current version of UPROG program is available in free mode and can be downloaded from the BOLID website www bolid ru Run the UPROG program and select CHANGE ADDRESS command with current and new S2000 V net number ranged from 1 to 127 as parameters Write the assigned address onto the S2000 V Marking Field By means of ADDRESS PROGRAMMING command it is possible to define a required detector address It is useful in the event when the same address is assigned to two or more detectors To do this activate the command in question with required net number as parameter from the computer Then make the long long long short pressing on the required detec
2. good device by manufacturer Ship off a failed S2000 V detector to the manufacturer for exchange with a damage certificate describing the defect and its acceptance certificate to validate the warranty status Send your complaints to the manufacturer at the following address ZAO NVP BOLID 4 Pionerskaya street Korolyov Moscow Region Russia 141070 Tel fax 7 495 777 40 20 7 495 516 93 72 E mail info bolid ru Web site http www bolid ru SECURITY SYSTEMS ACCEPTANCE CERTIFICATE S2000 V Addressable Vibration Intrusion Detector Product Designation Serial Number Produced tested by quality control department in compliance with state standards and specifications packed by NVP BOLID Company and qualified as deliverable Q C STAMP Name Date i SECURITY SYSTEMS
3. S 2000 V ca ADDRESSABLE VIBRATION INTRUSION DETECTOR ISO 9001 INSTRUCTION MANUAL DESCRIPTION Addressable Vibration Intrusion Detector S2000 V referred to as detector below is designed to detect break in attempts to Concrete walls and ceilings in thickness of at least 0 12 m Brick walls in thickness of at least 0 15 m Wood constructions in thickness of 20 to 40 mm Plywood in thickness of at least 4 mm Wood clip board in thickness of at least 15 mm Safes cabinets doors automatic teller machines ATM and other enforced physical areas The S2000 V detector is to be mounted on a protected surface It senses vibrations caused by an attack any gaps or crack in the material and when the protected surface is shaken the detector generates an alarm signal The detector operates as a part of Orion security system and is connected to a S2000 KDL two wire communication line controller powering it and receiving the alarm signal if happened S2000 V detector is designed to work around the clock FEATURES Sensitivity adjustability for different applications LED indicating of current operating mode and protected construction vibration Net address programming and bidirectional S2000 V to S2000 KDL data communication Sabotage protection due to a built in tamper switch enabling to detect unauthorized cover removing Protection against removal of detector from its mounting surface SPECIFICATIONS Power Supply from S2000 KDL via 2 wi
4. ives the NORM response In case of any destructive effect having detected the S2000 V detector transmits the ALARM message to the S2000 KDL controller The attack having been stopped the detector has been recovering within 10 s If a detector removal from its protected mounting surface is detected S2000 V transmits a TROUBLE message to the S2000 KDL controller the detector LED flashing with 2 Hz frequency until the trouble having been repaired When recovered the detector restarts If no reset the detector manually by having disconnected from two wire communication line or by having made short long short short short pressing on the detector tamper switch that is having made a program reset More specifically the detector indication and operating techniques are described in S2000 KDL controller User s Manual OVERALL AND MOUNTING DIMENSIONS All dimensions are defined in mm i SECURITY SYSTEMS WARRANTY Manufacturer warrants its S2000 V Addressable Vibration Intrusion Detector to be in conformance with specification under normal transportation storage mounting and maintenance Manufacturer warrants its product to be free from defects in materials and workmanship for 18 months since putting the S2000 V detector into operation but no more then 24 months since production under normal use and service In the event of in warranty failure having occurred within warranty period the failed S2000 V detector should be replaced with known
5. r removal from its mounting surface flashing with 2 Hz frequency 1 Technological Mode when delivered The 2000 V detector senses long periodically impacts the LED flashing by three in series After impact having accumulated the detector generates an 2 First Threshold Value can be chosen alarm signal being lighting steadily within 3 s Then the alarm is dropped The LED flashes with 2 Hz frequency indicating detector removal from its mounting surface The 2000 V detector senses short periodically impacts the LED flashing singly After impact having 3 Second Threshold Value can be chosen accumulated the detector generates an alarm signal being lighting steadily within 3 s Then the alarm is dropped The LED flashes with 2 Hz frequency indicating detector removal from its mounting surface The S2000 V detector senses both short and long 4 Combined 2 and 3 can be chosen periodically impacts the LED flashing in accordance with detected vibration behavior The detector cover has been being put on and the tamper switch has been being closed for more than 5 s The LED behavior corresponds to chosen operating technique Operating Mode when chosen i SECURITY SYSTEMS Material or Unit to Be Protected Steel cabinet safe door ATM unit deposit box Table 2 Testing of Operating Techniques Simulative Impact Application and Detector Sensitivity Monitoring Put a steel plane onto protected surface a
6. re communication line Consuming Current 2 mA maximum Power Up Operation Readiness 5 s maximum Operating Temperature Range 30 C to 50 C Relative Humidity up to 93 for 40 C non condensing Overall Dimensions 68x43x20 mm Weight about 25 g DELIVERY SET S2000 V Detector 1 pcs Instruction Manual 1 pcs Screw nail 1 4x30 20 019 1 pcs Screw M4x25 48 016 1 pcs Screw nut M4 6H 5 016 2 pes Spacer 4 651 019 1 pcs Spacer 4 04 019 2 pes Anchor 72204 MSA 4 1 pcs Package 1 pcs l SECURITY SYSTEMS DETECTOR MOUNTING S2000 V detector can be used to protect separate areas or entire surfaces in premises Typical detector application is demonstrated below where A1 is a S2000 V detector and L is the range or coverage Basic Construction Protection S1 gt 75 S2 lt 25 Overall Construction Protection S 100 Adjacent Construction Protection L2 3 4 L1 Glassed in Constructions oat A 2 12 TA Ll Non Monolithic Construction Protection Hollow Core Door Protection Gs ss L1 lt L2 Veneer sheet in thickness of 4 to 10 mm PIN Safe Protection Self service zone box zZ To fix a S2000 V detector onto the brick or concrete surface use the anchor provided To mount the S2000 V detector onto the wood or wood clip board surface use the supplied screw nail If the S2000 V is to be installed to protect ATM unit mechanism housing or user panel against vandals attach it
7. s far as possible from the detector Drill the hole into the plane until LED has become flashing by three in series Comment Plane thickness is 5 7 mm drill bit diameter is 3 5 mm and drill rotation frequency is 1500 2500 rpm Wood plywood or wood clip board Attach a wood block at the boundary of a protected zone Saw the block until LED has become flashed in short threefold manner The block size is approximately 75x75x300 mm saw tooth pitch is 5 10 mm saw gullet depth is 4 8 mm Concrete or brick construction Apply a plane made of fabric or paper based laminate to an edge of a construction protected zone Lay a number of hammer blows on this plane until LED has flashed singly ATM unit user panel Implemented as mentioned above Lay hammer blows through a plane on different user panel areas simulating attack SECURITY SYSTEMS Plane thickness is 10 20 mm plane size approximately 150x150 mm hammer weight is 0 4 0 6 kg pauses between blows are from 0 1 up to 30s 2000 V DETECTOR OPERATING A S2000 V detector being powered up the detector LED will light and the RESTART message will be transmitted to a S2000 KDL controller signaling self adjustment being in process Do not take any actions or touch detector or protected construction until LED has gone off After self adjustment having been successfully completed the S2000 V LED goes off and the S2000 KDL controller rece
8. sensitivity If the detector has perceived a vibration it flashes triply accumulates impacts and then generates an alarm signal LED indicator being lighting steady within 3 s i SECURITY SYSTEMS In order to adjust the detector sensitivity turn the Sensitivity Adjustment Control clockwise slowly to find the position the LED indicator doesn t light up near the noise of ordinary level HOW TO CHOOSE THE DETECTOR OPERATING MODE All detector available operating modes are shown in Table 1 When received the detector is in technological mode The suitable operating mode which can be 2 3 or 4 can be chosen by experiment depending on required impacts to be detected Operation mode testing is carried out in accordance with the technique demonstrated in Table 2 Press on the detector tamper switch as many times as required mode number each pressing increasing it by one The number of LED flashes indicates the number of chosen mode After fourth mode the first one will be indicated Having completed testing save the chosen operating mode by pressing and holding the tamper switch for more than 5 s LED indicator being light up in the event of success Then the detector enters the operating mode in accordance with chosen technique Finally replace the detector cover Table 1 S2000 V Detector Available Modes of Working Mode Description The S2000 V detector is signaling an alarm and is not response on any impact LED indicates a detecto
9. tor tamper switch The term long signifies keeping during at least 0 6 s and no more than 5 s while short one signifies pressing within no more than 0 6 s the pause between pressings not exceeding 10s The address having been changed the detector LED will flash triply and the computer will display the message reporting the detector with programmed address having connected If two detectors had the same address before the new address programming then the computer will not display the detector with former address disconnection Do not forget to write the assigned address onto the S2000 V Marking Field To learn more about giving of net numbers to addressable devices included into two wire communication line refer to S2000 KDL controller S2000 M console or ARM Orion User s Manual To adjust the detector remove its cover then power the detector on and wait until LED indicator has gone off When delivered the detector operates in technological mode see Table 1 To enter setting mode make long short short short long pressing on the detector tamper switch the detector LED flashing once In the event of a wrong pressing wait for 10 seconds and repeat pressing HOW TO ADJUST THE NOISE SENSITIVITY THRESHOLD Press the detector tamper switch and hold it for 1 5 s The detector LED will flash twice indicating second mode having entered see Table 1 Turn the Sensitivity Adjustment Control to its left end position that complies with maximum
Download Pdf Manuals
Related Search
Related Contents
Cables Direct B6-505 networking cable AT-LA 500 USER MANUAL L`IDIOME(1)viennent Psi series GB-NL-FR-ES-D-IT gebrauchs- und montageanleitung operating and RocketFish RF-GUV1124 Network Card User Manual Télécharger les modalités de réponse électronique Bedienungsanleitung シャワートイレ取扱説明補足版 Copyright © All rights reserved.