Home
Additel ADT 916 Pressure Test Pump Manual PDF
Contents
1. Warnings and cautions Avoid possible damage when suddenly apply pressure to low pressure and small chamber gauges Do not exceed the safety pressure limit 1000 psi Compressed air may cause problem in explosive or corruptive environment Do not shift between pressure and vacuum mode under pressure Do not over tighten connectors to avoid any damage Store the pump in the dry and non corruptive environment Any security problems or damages caused by incorrect operation is beyond Additel s responsibility Specification Pressure range 14 psi 0 95 bar vacuum to 600 psi 40 bar positive pressure Temperature 0 50 Humidity lt 85 RH Adjusting fineness 10 Pa 0 1 mbar PND T Q 6 Safety pressure lt 1000 psi 70 bar Pneumatic Pressure Test Pump User s Manual Pressure media Air Version number 1103V10 Size Height 5 5 140 mm Base 12 4 315 mm x 7 8 198 mm Weight 6 0 lb 2 7 kg Remark If local atmosphere pressure is I bar the vacuum can reach to 0 95 bar If local atmosphere pressure is P the vacuum can reach to 0 95P bar Configuration amp Air routine 1 1 4 NPT connector Air routine 2 Isolating valve isolate the calibration from pressurizing system 3 Pressure lever 4 Fine adjust handles clockwise to increase pressure f enna s CHIX 5 Security bolt pin use it to ensure safety 6 Pressure vacuum selector 3 A Pressure pull it out V
2. acuum push itin 7 Release valve clockwise to close anticlockwise to open Troubleshooting The isolating valve is not open Open the isolating valve A Release valve is not closed Close the release valve C P V selector is in wrong position Pressure pull it out Vacuum push it in B The gauges is not tightened Tighten the reference gauge or the gauge under test D The thread surface is not smooth Put in a Teflon seals and turn it tightly F The impurity blocks the air routine Repeat pressurizing several times and then release it suddenly make airflow to bring the impurity out B The new pump is not smooth The new pump needs time to abrade C The threads have no lubrication Lubricate the thread dial gauge pressure switch Connection pressure transmitter flexible hose Open to atmosphere Pre pressure Fine adjust process Zeroing should be operated under this condition only operate it to get the desired value 1 close do not use too much force QN gt ji Y Close do not Me a ANN set it to the use too much amp mid position Pi S sA of its travel Pressurizin rocess Decrease pressure process operate it to get the desired value 1 open it slowly to getthe desiredvalue and close Repeat Vacuum process Decrease vacuum process T operate it to get the desired value open it slowly to get the lall desired value YS and close operate it t
3. o get the desired close but it 4 C must be open LS 5 when select lla la push in select the vacuum position Remark A Additel has made a concerted effort to provide complete and current information for the proper use of the equipment The product specifications and other information contained this manual are subject to change without notice B Above pictures are just for reference
Download Pdf Manuals
Related Search
Related Contents
Téléchargez la version PDF des fonctions d`appel. 協約ず法SPD MKYシリーズ 取扱説明書 Copyright © All rights reserved.
Failed to retrieve file