Home

LED Matrix light manual STL-025

image

Contents

1. or decrease the parameter ENTER Confirm the selected item or parameter i e enter the next menu or escape the current menu and save the selected item or parameter Common operations Stand alone operation Press ESC button until the lighting shows S amp amp then press ENTER to enter the SET menu and use UP or DOWN buttons to browse to NAAL then press enter to enter and browse to Ai an and then press ENTER to confirm the lighting enter Stand alone mode Master and slave operation 1 Connect DMX OUT of the first lighting to DMX IN of the second lighting with DMX signal cable and then connect DMX OUT of the second lighting to DMX IN of the third lighting and so on 2 Set one lighting to master device others to slave device then all lightings run synchronously flow the master device Master setting method Press ESC button until the lighting shows S amp then press ENTER to enter the SET menu and use UP or DOWN buttons to browse to NAAL then press enter to enter and browse to ASE and then press ENTER to confirm Slave setting method Press the menu to AG position with actually stored address DMX mode In DMX mode the lighting can controlled by controller 1 Connect controller to DMX IN of the first lighting connect DMX OUT of the first lighting to DMX IN of the second lighting then connect DMX OUT of the second lighting to DMX IN of the third lighting and so on Insert a termination plug in the ou
2. Blinder Matrix 5x5 LED warm Beam 6dgr DMX3 Please read the manual before installing and using this lighting Keep it for future reference Contents Safety information cece ceeeceeeeeceeeeeeeeeeeeeeeeeaeeeeeseaeeeesseeeeeesaaeeeessaeeeeeeas 2 DIMENSIONS maranana e e cteestnesteacier atin TT 3 POWSr CONNECCION suosiossa EEES 4 Mallal 4 eenen a eee ner ee eee a ee 6 Ge ah ve ie ors g bazeren te ect etcetera eter ete e E 8 COMMON operationS ccccceecccceeeeeceececeeeeeeeeeeecaeecesseeeesseeeesseeeesseeeesseeeeeas 8 Stand alone ODE ANON sssaaa aiaia IT 8 Master and slave operation ccccsscccsseeceeeeceeeeceueeseueeseueeseeeeseueesees 8 OMA OCC ante te tate etal t te tute ace cieeceuce EO 9 DOMA ON Ol OC ON ioc attire cere ee acca hacia tae E E E E 10 PON T O E E A asa se at ls esc NEONO TE 12 TECMMIGAI SOSCINCANONS seans 14 ENL www 2rent se Thank you for purchasing our product Upon receiving the lighting please carefully check that there has been no damage caused in transportation If the lighting has been damage do not use the lighting and contact your dealer or manufacturer This product complies with the following standards IEC60598 1 2003 IEC60598 2 17 1984 A2 1990 Safety information 35 important All operation and maintenance must be carried out in accordance with this user manual Manufacturer will not with responsibility for those operations not according to this In
3. e power in socket of the subsequent lighting and so on Lighting Warning ve BOTELEAGSBAEEOESE i ERHEBEN oe o aunmn D REDRSTELOOIDETERY EY EREET ISTIS pARRHIHIHHH ho GHRHIHHHHH GRRE HDEPN Install the safety cable to the structure and anchor the cable to 2 The power cable must is a three conductor 2 5mm cable the dedicated attachment point on Do not connect more than 8 lightings in total to AC mains power in one the base The attachment point is symm J Maan o Emm LENEERENERER EERE fe LU ai jf ReGasea Aaa EE EERE HHIRHHIRE f interconnected daisy chain l l l designed to fit a carabiner clamp GR SY a QR am a prey Be pano r SOSEQGIERERGHERSEOR A T OTTO BTU a a ERENLER EEOAE OEELA IR EREA EEN amp Giro iiil iiti iiaii iiias iati oi Haiii iii diiit ii iili iii tiil iii ti taii ii pannen ATT enm SPP o semen 6 peeeyeantantantiny lt gt AESRERRRSERETE pEURRREIE HEHEIHIEIHE S HENHEIRIEIN lo ia e v Stacking the lightings vertically and horizontally by the locks on the side pe BZ ae bas 3 Be onos J SEPN AN R A E EE ERE h CEEI EHEN EEA A E H NEEE i iida a diii i itii itidal k seit keiiticcheeilbiebietibihiihetile ei e Control panel Button functions ESC Call the main menu or escape the current menu i e return to the upper menu and give up the selected item or parameter UP Browse the menu item forward or increase the parameter DOWN Browse the menu item backward
4. ll screws are tightly fastened Don t move the cord directly It s only allowed with the handle Dimension oo Tt g7 fi f Note User can order the optional handles separately from our company according application the handles are not supplied with the product like the below picture All dimensions are in millimeter Power connection Verify that the voltage matches the rated voltage Make sure power socket is connected with earth cable well Installing a Neutrik connector on a power cable 20mm Housing Insert Chuck Bushing Put bushing and chuck onto the cable Prepare cable as shown above The power cable must is a three conductor 2 5mm cable Insert the wire into the terminals and fasten the clamping device by a flat screw driver Push insert and chuck into housing pay attention to the guiding keyway Fasten bushing the color coding schemes and some possible pin identification schemes if pins are not clearly identified or if you have any doubts about proper installation consult a qualified electrician Wire color Conductor Symbol Brown L Blue N Handling Engagement Relaying power to other devices The lightings can be linked in a chain by power cables which installed a blue and a light gray connectors on the two ends The light gray connector connects to the power out socket of the first lighting and the blue connector connects to th
5. obe8 random burst pulse fast to slow shutter open Built in scenes oo Nomad CH3 000 009 No effect 010 155 Built in programs 30 channels mode 000 255 Global Dimmer dark to bright 000 005 006 064 065 069 070 084 085 089 090 104 105 109 110 124 125 129 130 144 145 149 150 164 165 169 170 184 shutter open strobe1 fast to slow shutter open strobe2 opening pulse fast to slow shutter open strobe3 closing pulse fast to slow shutter open strobe4 random strobe fast to slow shutter open strobe5 random opening pulse fast to slow shutter open strobe6 random closing pulse fast to slow shutter open strobe7 burst pulse fast to slow CH2 000 005 shutter open 006 064 strobe1 fast to slow 065 069 shutter open 070 084 strobe2 opening pulse fast to slow 085 089 shutter open 090 104 strobe3 closing pulse fast to slow 105 109 shutter open 110 124 strobe4 random strobe fast to slow 125 129 shutter open 130 144 strobe5 random opening pulse fast to slow 145 149 shutter open 150 164 strobe6 random closing pulse fast to slow 165 169 shutter open 170 184 strobe burst pulse fast to slow 185 189 shutter open 190 204 strobe8 random burst pulse fast to slow LoFF 205 255 shutter open LOIAAL Master stand alone setting CH3 HAASE Master mode 000 009 no eee ton Stand alone mode 010 155 Built in programs FELS Temperature control it will reduce the output 156 255 No effec
6. ons 575 5 75 90mm whithout handle Net weight 9 6kg
7. struction Verify that the voltage matches the rated voltage Always disconnect the power before attempting to open the equipment housing or carrying out any maintenance Do not connect power cable of other electric products with this unit Make sure power socket is connected with earth cable well The earth cable of this unit is Yellow Green one Do not expose the fixture to rain or moisture Verify that the feed cables are undamaged and rated for the current requirements of all connected devices before use Never attempt to bypass the thermostatic switch or fuses Always replace defective fuses with ones of the specified type and rating Ensure that the air flow through fans and vents is free and unobstructed Keep all combustible materials for example fabric wood paper at least 0 3 meter away from the light Keep flammable materials well away from the fixture Avoid looking directly into the light source especially those who suffer from epileptic fits When it is thunderstorm don t use the light and disconnect the power supply high voltage will destroy light The max ambient temperature is 40 C When suspending the fixture above ground level verify that the structure can hold at least 10 times the weight of all installed devices Verify that all external covers and rigging hardware are securely fastened and use an approved means of secondary attachment such as a Safety cable Verify that a
8. t FEMS after over temperature For Enable the switch default SFr Disable the switch 000 255 LE ENP password protected 001 255 HOARE Capture the current temperature 000 255 Individual LEDs dimmer dark to bright ESEE Set the value of the TC switch LEAR Fan speed control FFoit Full speed Menu Auto Auto Loft Soft information Menu Navigation eee dH SET Menu ESC A90 gt ENT gt DMX Menu H iets eo eee UL oe ZON L ERS Channel mode selection SET Menu ESC amp g gt ENT Adjustment menu EP R36 25 channel mode default UP f DN F ERGS 5 channel mode SET Menu ESC 5L n gt ENT gt Scenes menu L R30 30 channel mode UP T LDN SET Menu ESC oi7 ENT Built in program menu 3 Adjustment menu UPT IDN Ad bod i Global dimmer eagg 255 1 SET Menu Lot ob SEE L 000 255 Strobe O no stobe 1 255 fast to slow L ELad Reload default 4 Scenes Menu SLER Faoi Select scenes 0 027 Foin Dimmer gog 255 LStob Lgg 255 Strobe O no stobe 1 255 fast to slow 5 Built in program menu Prob Built in programs bP rw Select built in program LOG 1 020 FSPEJ Program speed a J C i Global dimmer Technical specifications Voltage 100 240V 50 60Hz Power 330W light source 25 pcs 10W white LEDs Control mode DMX Mode Master slave mode Channel QTY 5 25 30selected by menu IP rating IP 20 Working temperature 20 C 40 C Dimensi
9. tput of the last fixture on the link The termination plug which is a male XLR plug with a 120 ohm 0 25 watt resistor soldered between pins 2 and 3 soaks up the control signal so it does not reflect and cause interference Press the menu to AYU position with actually stored address the lighting enter DMX mode Set DMX address While the lighting shows ADD i with actually stored address press enter it shows DMX press ENTER again and use UP or DOWN buttons to browse to Hdd then press ENTER to enter and use UP and DOWN to adjust the DMX address and press ENTER to save it In DMX mode a fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that uses 3 DMX channels and was addressed to start on DMX channel 1 would read data from channels 1 2 3 Choose start addresses so that the channels used do not overlap and note the start address selected for future reference Note that assign the same address to the different lightings they will receive the same signal DMX protocol This lighting has 3 channel modes 25 channels mode 5 channels mode 30 channels mode The default mode is 25 Channels Mode If you want to alter it enter DMX menu 25 channels mode CH1 CH25 000 255 Individual LEDs dimmer dark to bright 5 channels mode 000 255 Global Dimmer dark to bright 185 189 190 204 205 255 shutter open str