Home

User Manual

image

Contents

1. J mic r7 Fig 2 health and safety always use safety gear suited for the task and follow company guidelines and all relevant rules and norms for installation where applicable Do not open any part of the luminaire without disconnecting line voltage The luminaire is to be used in Zone 1 Zone 2 or Safe Area Warning The lamp can only be installed in Zone 1 and Zone 2 if equipped with ATEX and IECEx approved cable glands and stopping plugs SPARE PART Description Transformer 2 x 127V 1 x 24V Terminal block EEx e Part No 5086 0078 5028 0008 TEF 2430 LED PERIMETER LIGHT USER MANUAL Stopping Plug Exe TEF794 M25 9mm Brass 650 2500 Globe unit low complete with LED driver and green LED s 4500 Cable gland E204 M25 D with lock nut 12 0 20 1 mm 9mm Brass 6222502 TECHNICAL DATA Type Description Material Supply input voltage T rating Light source Power comsumption Ingress protection Weight Tamb Compliance with Tranberg AS P O Box 8033 N 4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com TEF 2430 LED
2. 30 C 50 C Notified body Nemko AS Norway The product is fully assembled and ready for installation CSA International Canada INSTALLATION INSTRUCTIONS SAFETY PRECAUTIONS Only qualified personnel are allowed to perform installation Note that changes made to the product and or installation ANE MAMENANG TASKE Lot ie SARN of components which do not conform to the approval may be a safety violation The manufacturer will in no circum stance be held responsible for such activity For your health and safety always use safety gear suited for the task Be certain to follow codes regulations and or specific procedures that are related to the installation The equipment is ready for installation when leaving the production facilities of Tranberg AS Check the condition of the equipment and the contents when unpacking Any damage done to the equipment during the transportation is not the responsibility of Tranberg AS If the content is not complete file a claim to the producer immediately The TEF 2430 is mounted on a bracket which have several mounting choises using 2 pcs of M8 max bolts and nuts TOOLS REQUIRED or a 2 pipe The dimensions of mounting board are shown Regular tools required for installation in fig 1 e Tools for mounting e g 13 mm wrench to fasten the Important when mounting the luminaire luminaire 3mm hexagon key Unbrako for lock unlock safety The luminaire must always be installed in such a wa
3. Perimeter light Luminaire for use in zone 1 2 and safe area Lamphouse Copper alloy brass Junction box AISI 316L Globe polycarbonate Lexan Depending on model ref datasheet for details T5 High power light emitting diodes Ref datasheet for details Max 11 W IP66 67 without drainplug IP54 with drainplug According to IEC 529 6 kg 30 C to 50 C Arctic version 55 C to 50 C CENELEC EN 60079 0 2012 CENELEC EN 60079 1 2007 CENELEC EN 60079 7 2007 CSA Standard C22 2 No 0 M 91 General requirements Canadian Electrical Code Part Il CSA Standard C22 2 No 0 4M 1982 Bonding and Grounding of Electrical Equipment Protective grounding CAN CSA Standard c22 2 No 43 M 1984 Lampholder CAN CSA Standard c22 2 No 250 0 00 Luminaires CAN CSA E60079 0 02 Electrical Apparatus for explosive gas atmospheres Part 0 General Requirements CAN CSA E60079 1 02 Electrical Apparatus for explosive gas atmospheres Part 1 Flameproof Enclosures d CAN CSA E60079 7 02 Electrical Apparatus for explosive gas atmospheres Part 7 Increased safety e UL 1598 2000 First Edition UL Standard for Safety Luminaires UL 542 1999 Eight Edition UL Standard for Safety for Lampholders Starters and Starter Holders for fluorescent Lamps UL 935 2001 Tenth Edition UL Standard for Safety for Fluorescent Lamp Ballasts ANSI UL 60079 0 2002 First Edition Electrical Apparatus for Explosive Gas Atmospheres Part 0 General Re
4. TEF 2430 LED IEGEx PERIMETER LIGHT USER MANUAL IMPORTANT Read this instruction carefully before installing the product Lz 173 304 REV E 14 10 2014 TRANBERG Tranberg AS P O Box 8033 N 4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com TUM 1073 TEF 2430 LED PERIMETER LIGHT USER MANUAL INTRODUCTION APPROVALS Thank you for purchasing this product Explosion category I12G Ex de OPIS IIB Gb T5 For installation maintenance and assurance of a long life ATEX IECEx of this product please follow this manual Ex de IIB T5 Canada Class Zone 1 AEx de IIB T5 USA Certificate No IECEx DNV 13 0016X Nemko O3ATEX064X 216432 APPLICATIONS Approved for use in Zone 1 Zone 2 and Safe Area e Perimeter lights on helideck green light Marking C 0470 Il2 GExde OP IS e Zone 1 zone 2 and safe area IIB Gb T5 Ex de IIB TS Class Zone 1 AEx de IIB T5 CONTENT IN BOX Tamb
5. e not to be grounded Make sure electrical connections are safe and reliable Make sure the wire slack is as needed Reinstall the cover If properly mounted and installed the luminaire is now ready for use Replacement of LED unit Deactivate the input power Loosen the safety pin Remove the ring with globe and replace the entire LED unit If necessary lubricate the threads with grease Renolit Unitemp 2 from Fuchs Reinstall the ring with globe and guard and fasten the safety pin Troubleshooting No light Check main power connections to the terminals blocks or wire to the LED unit If the light still does not function contact the nearest Tranberg dealer or Tranberg AS directly Safety precautions Note that changes made to this product and or installation of components which do not conform to the approval may be a safety violation The manufacturer will under no circumstances be held responsible for personal injuries death or any damage caused by such activity For your J Fig 1 p 129 90 E Bracket a85 OL F 7 0 i 3 i E gt 4 120 ee Ye L a ae p 120 e ie x oe cn aaa
6. lcohol or the junction box petroleum based products may damage lens paint or plastic components When cleaning the dome use moist cloth to avoiding electrostatic hazard Not following these instructions may lead to a risk of water ingress into the luminaire The manufacturer assumes not responsibility when these guidelines are not followed TEF 2430 LED PERIMETER LIGHT USER MANUAL The terminal block of this luminaire is of the cage clamp type and one needs either special tool or just a small flat head screwdriver to connect the cable to terminal block The cable glands are approved for a specific cable diam eter These data can be found in the certificate of the ATEX approved cable glands Make sure this is not violated Use of cable with other dimensions is a safety violation and should be avoided Any damage caused by use of incorrect cable gland not matching the cable dimension is not the responsibility of Tranberg AS and is not covered by warranty Max cross section of the cable to be connected to the terminal blocks is 2 5 mm To connect the wiring of the TEF 2430 LED perimeter light perform the following procedure Remove the cover from the connection box Connecting cable for 230 120 VAC 50 60 Hz The main power 230 120 VAC is to be connected to the terminal blocks marked 1 and 2 Connecting cable for 24 VDC VDC The main power 24 V is to be connected to the terminal blocks The 24VAC VDC version ar
7. quirements ANSI UL 60079 1 2002 First Edition Electrical Apparatus for Explosive Gas Atmospheres Part 1 Flameproof Enclosures d ANSI UL 60079 7 2002 First Edition Electrical Apparatus for Explosive Gas Atmospheres Part 7 Flameproof Enclosures e TRANBERG Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com
8. y pin on the guard ring that the junction box is fully supported from underneath e Flatheadscrewdrivers approx 3 5mmforconnectingto Normally the entire luminaire would be installed to a flat terminalblockand8 Ommforjunctionboxlid earthscrew surface which provides a proper support for the junction e 32 mm wrench to disassemble the blind plug and box In cases where the junction box cannot be mounted assemble the cable gland on the same surface as the lamp housing bracket a full e 25mm wrench for tightening the pressure nut on the and rigid support must be provided for the junction box An cable gland unsupported junction box may be damaged if stepped upon Likewise an unsupported junction box that is forced down by e g a pull of electrical cables may expose the gasket between the junction box and lamp housing MAINTENANCE INSTRUCTIONS Do not use excessive force when tightening the four Screws on the junction box lid and never use a power screwdriver The luminaire should be inspected according to Company Excessive force may bend the lid and provide a way for routines The manufacturer suggests regular check for water to enter the junction box When closing the lid on the water intrusion condensation which should be removed junction box please ensure that no electrical wires or the immediately Check the drain plug drain hole function safety wire to the lid itself are jammed between the lid and When cleaning use only mild detergents A

Download Pdf Manuals

image

Related Search

Related Contents

Jensen VM9224R User Guide Manual - CaRadio  Samsung SCX-4720FN 用户手册  Fujitsu LIFEBOOK S752  PS-S553  Viamobil V25 - Manuale d`Uso  SUNSHIELD 312 Installation Guide  PFN-2000 Series User Manual  Lenoxx HT-377 User's Manual  Montage- und Betriebsanleitung  METRICO ESTIMATIVO R.11.a ELENCO PREZZI UNITARI DI  